createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719295081912
version10
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd3663000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-09-2024 17:00:00
tenderQueryClose31-08-2024 16:00:00
technicalBidOpen03-09-2024 17:01:00
publishedDate02-08-2024 17:36:41
publishedByPostIDD_EE_DIV_UDP
publishedByUserKPE12286 - M V PRASAD
bidValidityPeriod90
noOfCalls1
preBidMeetingDate13-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonBhanuprakash
splitEmdRequiredYnTrue
emdBankGuarantee3563000.00
emdCash100000.00
bgValidityPeriod180
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08202532961
mobileNumber9900328119
tenderSupplierListNone
tenderSchedule
createdTs1719295081943
version22
createdDateNone
modifiedDateNone
tenderNumberIDD/2024-25/OW/WORK_INDENT36
titleCONSTRUCTION OF BALANCE WORKS OF 3RD STAGE EXPANSION PROJECT IN MANGALORE FISHERY HARBOUR DAKSHIN KANNADA DISTRICT
descriptionBALANCE WORKS OF 3RD STAGE MANGALORE FISHERY HARBOUR AT DAKSHINA KANNADA DISTRICT
categoryWORKS
categoryTextWorks
ecv366324803.51
deptNameInfrastructure Development Ports And Inland Water Transport Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5472
locationNameExecutive engineer Udupi
provisionalAmount495000000.0
groupOverheadTotal0.0
fileNumberKMB/PFSD/MLR/3RDSTAGEBW/AE-1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17192950820000NoneNoneOther Works01 DREDGING AND DISPOSAL12668409.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341273117393NoneS.R.I.No. 5, P.8, Vol-7 PWD SR 2021-22 continuedDredging in front of existing/ proposed quay and in the harbour basin, entrance channel/Inlet/ Bar mouth from existing levels to required levels & slopes in the specified area marked in the drawing/ as directed by port authority, in all types of soils, pebbles, soft rock etc. using Grab/ Backhoe or any other suitable dredger and carrying/ transporting in hopper barges and disposing in the dumping area located in deep sea at an average distance of 10 Kms, including cost of all machineries, hire, operation and maintenence charges of all equipments complete with all leads, lifts, loading, unloading and incidental charges of all materials, labour and machineries etc., complete and as directed by the Engineer-in-charge of work. Dredging Level 0 to -5.00 Mtr Cum234.08234.0854120.0FalseNoneNoneFalseNoneFalse12668409.60
17192950820000NoneNoneOther Works03 REVETMENT AND PITCHING4034292.54
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341274117394NoneI.No. 1.8, P.No.7 of PWD Common SR 2023-24 Vol- IConstruction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum504.34504.34346.5FalseNoneNoneFalseNoneFalse174753.810
3341275117394NoneS.R.I.No. 14.6, P.129, of PWD SR Roads and BridgeGeotextile Filter: Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/ cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.Sqm125.44125.442151.0FalseNoneNoneFalseNoneFalse269821.440
3341276117394NoneS.R.I.No. 14.4.A, P.129, Vol-3 PWD SR 2021-22 coProviding and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications- Stone/BoulderCum2141.442141.441676.31FalseNoneNoneFalseNoneFalse3589717.28640
17192950820000NoneNoneOther Works04 QUAY (RCC D,WALL - PILE JETTY)86543785.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341277117395NoneI.No. 1.8, P.No.7 of PWD Common SR 2023-24 Vol- IConstruction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum530.88530.88666.0FalseNoneNoneFalseNoneFalse353566.080
3341278117395NoneS.R.I.No. 3, P.1, Vol-7 PWD SR 2021-22 continuedProviding and laying in position sand/stone grit filled Nylon bags for Coffer dam to working platform to the required formation and garade as shown in drawing etc., complete including cost of all materials, labour, HOM of Machinery with all lead lifts, complete as per specification as directed by the Enginee Incharge of the work.Cum1239.841239.84310.8FalseNoneNoneFalseNoneFalse385342.2720
3341279117395NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.242787.74FalseNoneNoneFalseNoneFalse318471.41760
3341280117395NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92335.07FalseNoneNoneFalseNoneFalse99824.05440
3341281117395NoneI.No. 2.1.4, P.No.15 of PWD SR 2023-24 Vol-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6963.046963.04321.32FalseNoneNoneFalseNoneFalse2237364.01280
3341282117395NoneI.No. 2.4.2, P.No.16 of PWD SR 2023-24 Vol-1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including FormworkCum9560.389560.3885.41FalseNoneNoneFalseNoneFalse816552.05580
3341283117395NoneS.R.I.No. 1.2, P.7, Vol-7 PWD SR 2021-22 continuProviding and placing in situ reinforced cement concrete of M35 grade using tremie pipe for diaphragm wall / Anchor wall of 600mm thick including Boring / Excavation through all strata except hard rock to the requisite specified depth and using mechanical equipments including charges towards retaining the sides from collapsing using bentonite mud circulation and disposing of the excavated materials etc.,including the the cost of lowering the cage but excluding the cost of reinforcement, including cost of all materials, labour complete as per specificaitons with all leads, lifts, loading , unloading and incidental charges of all materials, labour and machineries etc., compleand as directed by the Engineer-Providing and placing in situ reinforced cement concrete of M35 grade using tremie pipe for diaphragm wall / Anchor wall of 600mm thick including Boring / Excavation through all strata except hard rock to the requisite specified depth and using mechanical equipments including charges towards retaining the sides from collapsing using bentonite mud circulation and disposing of the excavated materials etc.,including the the cost of lowering the cage but excluding the cost of reinforcement, including cost of all materials, labour complete as per specificaitons with all leads, lifts, loading , unloading and incidental charges of all materials, labour and machineries etc., complete and as directed by the Engineer-in-charge of work. (Upto -10.00 M Level) in-charge of work.Sqm14728.014728.01628.0FalseNoneNoneFalseNoneFalse23977184.00
3341284117395NoneI.No. 19.3, P.No.187 of PWD SR for Building 2023-2Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2717.122717.12129.81FalseNoneNoneFalseNoneFalse352709.34720
3341285117395NoneI.No. 11.38, P.No.113 of SR 20223-24 Vol-III RoadsBored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. - 600 mm Dia pileRmtr7591.537591.531095.0FalseNoneNoneFalseNoneFalse8312725.350
3341286117395NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7551.047551.04426.08FalseNoneNoneFalseNoneFalse3217347.12320
3341287117395NoneI.No. 2.4.4, P.No.16 of PWD SR 2023-24 Vol-1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including FormworkCum10193.910193.9430.0FalseNoneNoneFalseNoneFalse4383377.00
3341288117395NoneI.No. 2.4.4, P.No.16 of PWD SR 2023-24 Vol- I)Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including FormworkCum7928.597928.59791.1FalseNoneNoneFalseNoneFalse6272307.5490
3341289117395NoneI.No. 2.11.a., P.No.18 of PWD SR 2023-24 Vol- ISteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -Foundation of BridgesMT96550.7296550.72308.41FalseNoneNoneFalseNoneFalse29777207.55520
3341290117395None13.10 of PWD SR 2023-24 Volume-03Providing Fusion Bonded Epoxy Coating (FBEC) to TMT Bars as per IS:13620-1993 specifications for a thickness of 175micron & permissible variation of 50micron including testing of coating. FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT a)Coating thickness shall be tested at a frequency of not less than one full length bar every twenty bars for each size b) Continuity of coating shall be determined by testing one full length bar in every twenty bars for each size c) Coating thickness over the whole of the coated bar section shall be determined by sectioning and examining one bar in every 20t for each size. d) For testing adhesion of coating, samples shall be selected from a ch size according to the frequency given as: For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge. (The item is to be operated with prior approval of Superintending Engineer)-8mmMT21280.021280.05.48FalseNoneNoneFalseNoneFalse116614.40
3341291117395None13.10 of PWD SR 2023-24 Volume-03Providing Fusion Bonded Epoxy Coating (FBEC) to TMT Bars as per IS:13620-1993 specifications for a thickness of 175micron & permissible variation of 50micron including testing of coating. FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT a)Coating thickness shall be tested at a frequency of not less than one full length bar every twenty bars for each size b) Continuity of coating shall be determined by testing one full length bar in every twenty bars for each size c) Coating thickness over the whole of the coated bar section shall be determined by sectioning and examining one bar in every 20t for each size. d) For testing adhesion of coating, samples shall be selected from a ch size according to the frequency given as: For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge. (The item is to be operated with prior approval of Superintending Engineer)-10mm MT16800.016800.014.63FalseNoneNoneFalseNoneFalse245784.00
3341292117395None13.10 of PWD SR 2023-24 Volume-03Providing Fusion Bonded Epoxy Coating (FBEC) to TMT Bars as per IS:13620-1993 specifications for a thickness of 175micron & permissible variation of 50micron including testing of coating. FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT a)Coating thickness shall be tested at a frequency of not less than one full length bar every twenty bars for each size b) Continuity of coating shall be determined by testing one full length bar in every twenty bars for each size c) Coating thickness over the whole of the coated bar section shall be determined by sectioning and examining one bar in every 20t for each size. d) For testing adhesion of coating, samples shall be selected from a ch size according to the frequency given as: For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge. (The item is to be operated with prior approval of Superintending Engineer)-12mm MT14560.014560.050.79FalseNoneNoneFalseNoneFalse739502.40
3341293117395None13.10 of PWD SR 2023-24 Volume-03Providing Fusion Bonded Epoxy Coating (FBEC) to TMT Bars as per IS:13620-1993 specifications for a thickness of 175micron & permissible variation of 50micron including testing of coating. FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT a)Coating thickness shall be tested at a frequency of not less than one full length bar every twenty bars for each size b) Continuity of coating shall be determined by testing one full length bar in every twenty bars for each size c) Coating thickness over the whole of the coated bar section shall be determined by sectioning and examining one bar in every 20t for each size. d) For testing adhesion of coating, samples shall be selected from a ch size according to the frequency given as: For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge. (The item is to be operated with prior approval of Superintending Engineer-16mmMT11200.011200.058.08FalseNoneNoneFalseNoneFalse650496.00
3341294117395None13.10 of PWD SR 2023-24 Volume-03Providing Fusion Bonded Epoxy Coating (FBEC) to TMT Bars as per IS:13620-1993 specifications for a thickness of 175micron & permissible variation of 50micron including testing of coating. FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT a)Coating thickness shall be tested at a frequency of not less than one full length bar every twenty bars for each size b) Continuity of coating shall be determined by testing one full length bar in every twenty bars for each size c) Coating thickness over the whole of the coated bar section shall be determined by sectioning and examining one bar in every 20t for each size. d) For testing adhesion of coating, samples shall be selected from a ch size according to the frequency given as: For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge. (The item is to be operated with prior approval of Superintending Engineer)-20mm MT9520.09520.0144.93FalseNoneNoneFalseNoneFalse1379733.60
3341295117395NoneI.No. , P.No.8 of PWD SR 2023-24 Vol- IEarth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum106.4106.45328.0FalseNoneNoneFalseNoneFalse566899.20
3341296117395NoneS.R.I.No. 7, P.8, Vol-3 PWD SR continued 2022-23Providing and fixing in position used rubber tyre fenders as specified in the drawing with all stainless steel fixing accessories supplied and fixed etc., including cost of all materials, labour complete as per specificaitons with all leads, lifts, loading , curing, unloading and incidental charges of all materials, labour and machineries etc., complete and as directed by the Engineer-in-charge of work. The stainless steel shall be of suitable grade and specification as required for marine conditions.Nos4008.484008.48480.0FalseNoneNoneFalseNoneFalse1924070.40
3341297117395NoneI.No. 11.1, P.No.77 of PWD SR for Building 23-24Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg118.72118.723510.0FalseNoneNoneFalseNoneFalse416707.20
17192950820001NoneNoneOther Works05 TRAFFIC AREA AND SURFACING112098206.34
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341298117396NoneI.No. 1.14.1, P.No.8 of PWD SR 2023-24 Vol- IEarth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.2425413.99FalseNoneNoneFalseNoneFalse2903294.21760
3341299117396NoneI.No. 1.8, P.No.7 of PWD SR 2023-24 Vol- IConstruction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum530.88530.8812709.13FalseNoneNoneFalseNoneFalse6747022.93440
3341300117396NoneI.No 4.1.A.ii, P.23, PWD SR 2023-24 Vol-IIIGranular Sub-Base- Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401-Plant Mix Method-For Grading II MaterialCum2867.22867.23491.47FalseNoneNoneFalseNoneFalse10010742.7840
3341301117396NoneI.No 4.17, P.26, PWD SR 2023-24 Vol-IIIProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory rollerto achieve the desireddensity.Cum2866.082866.082049.84FalseNoneNoneFalseNoneFalse5875005.42720
3341302117396NoneI.No 4.14.B.ii, P.26, PWD SR 2023-24 Vol-IIIProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. Grading-II (53 mm to 22.4 mm)Cum2345.282345.282290.5FalseNoneNoneFalseNoneFalse5371863.840
3341303117396NoneI.No 6.1, P.49, PWD SR 2023-24 Vol-IIIConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum5510.45510.4906.52FalseNoneNoneFalseNoneFalse4995287.8080
3341304117396NoneI.No 6.2, P.49, PWD SR 2023-24 Vol-IIIConstruction of M40 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawingCum10148.3210148.322314.7FalseNoneNoneFalseNoneFalse23490316.3040
3341305117396NoneI.No 16.28, P.149, PWD SR 2023-24 Vol-III)Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum7564.487564.481779.15FalseNoneNoneFalseNoneFalse13458344.5920
3341306117396NoneI.No 5.3.ii, P.31, PWD SR 2023-24 Vol-IIIProviding and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.25 kg/m2 on the prepared bituminous surface cleaned with mechanical broom- Tack coat on Granular surface treated with primerSqm15.6815.684945.0FalseNoneNoneFalseNoneFalse77537.60
3341307117396NoneI.No 5.6.1.B, P.31, PWD SR 2023-24 Vol-IIIProviding and laying Bituminous Macadam with 100 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compactionCum8263.368263.36229.65FalseNoneNoneFalseNoneFalse1897680.6240
3341308117396NoneI.No 5.31, P.43, PWD SR 2023-24 Vol-IIIProviding and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision.Cum11370.2411370.24157.08FalseNoneNoneFalseNoneFalse1786037.29920
3341309117396NoneI.No. 2.1.2, P.No.15 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.68334.1FalseNoneNoneFalseNoneFalse2119423.4880
3341310117396NoneI.No. 2.4.4, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including form workCum10193.910193.91183.45FalseNoneNoneFalseNoneFalse12063970.9550
3341311117396NoneI.No. 2.11.a., P.No.18 of PWD SR 2023-24 Vol- ISteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT95550.7295550.7282.84FalseNoneNoneFalseNoneFalse7915421.64480
3341312117396NoneI.No 8.57.c, P.79, PWD SR 2023-24 Vol-IIISupplying & fixing Composite Fibre Reinforced Polymer (FRP) utility cover conforming to IS 12592:2002 with sufficient load bearing capacity as per technical specifications. Light Duty Square 600x600 mm with load bearing capacity upto 5tNo3360.03360.027.0FalseNoneNoneFalseNoneFalse90720.00
3341313117396NoneI.No 8.57.d, P.79, PWD SR 2023-24 Vol-IIISupplying & fixing Composite Fibre Reinforced Polymer (FRP) utility cover conforming to IS 12592:2002 with sufficient load bearing capacity as per technical specifications. Heavy Duty Square 560x560 mm with load bearing capacity: upto 30tNo8960.08960.010.0FalseNoneNoneFalseNoneFalse89600.00
3341314117396NoneI.No 8.8, P.53, Vol-3 PWD SR 2022-23Direction and Place Identification Signs with size more than 0.9 m2 size Board.: Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67:2012 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area exceeding 0.9 m2 fixed over back support frame of min 40 x 40 x 5mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawingSqm9694.729694.7221.6FalseNoneNoneFalseNoneFalse209405.9520
3341315117396NoneI.No 6.8.3, P.52, PWD SR 2023-24 Vol-IIIProviding and laying 100mm thick factory made precast M -40 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions more than 10MSA upto 20MSA for Industrial Streets, Bus & Truck parking of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Sqm1456.01456.02700.0FalseNoneNoneFalseNoneFalse3931200.00
3341316117396NoneI.No 6.8.1, P.52, PWD SR 2023-24 Vol-IIIProviding and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification)Sqm1196.161196.162990.0FalseNoneNoneFalseNoneFalse3576518.40
3341317117396NoneI.No. 8.42.3, P.No.74 of PWD SR 20223-24 Vol-IIISupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stonem518.56518.561638.0FalseNoneNoneFalseNoneFalse849401.280
3341318117396NoneI.No. 2.1.4, P.No.15 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6963.046963.0419.96FalseNoneNoneFalseNoneFalse138982.27840
3341319117396NoneI.No. 8.23.ii, P.No.68 of SR 20223-24 Vol-IIIReinforced Cement Concrete Crash Barrier: Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-25 grade concrete with TMT reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at ocations directed by the Engineer, all as specified. (Area = 0.243 m2/m, single face): M 30 grade concretem2815.682815.68140.0FalseNoneNoneFalseNoneFalse394195.20
3341320117396NoneI.No. 8.10, P.No.66 of SR 20223-24 Vol-IIIPainting Two Coats on New Concrete Surfaces: Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm122.08122.08683.1FalseNoneNoneFalseNoneFalse83392.8480
3341321117396NoneI.No. 8.29, P.No.71 of SR 20223-24 Vol-IIICable Duct Across the Road: Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings. Double row for two utility servicesm4490.084490.08159.6FalseNoneNoneFalseNoneFalse716616.7680
3341322117396NoneI.No. 8.46, P.No.76 of SR 20223-24 Vol-III Providing and fixing Steel Pipe delineators of 100 mm. in diameter and total height of 1300 mm, provided with 2 strips of white retroreflective sheeting of size 50 mm. x 3250 mm. each fixed horizontally and 2 strips of red retroreflective sheeting each having size 50 mm. x 3250 mm. fixed horizontally at top, with M.S. round cap having diameter 11 cm. and wire mesh at top (10 guage thick) and height of wire mesh 15 cm, M.S. hold fast 6 mm thick with 35 cm. in length, fixing the delineators in C.C. 1:4:8 concrete block of size 250 mm. x 250 mm. x 450 mm. with necessary excavation etc. complete.Each1232.01232.0100.0FalseNoneNoneFalseNoneFalse123200.00
3341323117396NoneI.No. 8.13, P.No.66 of SR 20223-24 Vol-IIIPainting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work: Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164:2015 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic controlSqm227.36227.36817.2FalseNoneNoneFalseNoneFalse185798.5920
3341324117396NoneI.NO. 1.1, P.No. 05 Vol. III. Loading and Unloading of Stone boulders/ Stone Aggreagates/Sand/Kankar/Moorum (Tipper 5.5m3)Cum151.2151.27624.2FalseNoneNoneFalseNoneFalse1152779.040
3341325117396NoneI.No. 1.4a P.No. 05 Vol.IIICost of Haulage Excluding Loading and UnloadingT.Km13.4413.44137235.6FalseNoneNoneFalseNoneFalse1844446.4640
17192950820001NoneNoneOther Works06 FISH LANDING AND AUCTION HALL50138590.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341326117397NoneI.No. 19.3, P.No.187 of PWD SR for Building 2023-2Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2717.122717.1229.6FalseNoneNoneFalseNoneFalse80426.7520
3341327117397NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.24157.5FalseNoneNoneFalseNoneFalse17992.80
3341328117397NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6963.046963.0422.5FalseNoneNoneFalseNoneFalse156668.40
3341329117397NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Formwork-For Pile CapCum8155.128155.1272.0FalseNoneNoneFalseNoneFalse587168.640
3341330117397NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Formwork-Plinth BeamCum11326.5611326.56107.34FalseNoneNoneFalseNoneFalse1215792.95040
3341331117397NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Formwork-Internal DrainCum10193.910193.940.28FalseNoneNoneFalseNoneFalse410610.2920
3341332117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For ColumnsCum13341.3313341.3350.39FalseNoneNoneFalseNoneFalse672269.61870
3341333117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Beam and LintelCum12556.5412556.54107.29FalseNoneNoneFalseNoneFalse1347191.17660
3341334117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Including Form work Roof slabCum11771.7611771.76211.81FalseNoneNoneFalseNoneFalse2493376.48560
3341335117397NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For ChejjaCum11379.3711379.3736.89FalseNoneNoneFalseNoneFalse419784.95930
3341336117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work-Beam above 3.60 m htCum12635.0212635.0255.65FalseNoneNoneFalseNoneFalse703138.8630
3341337117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work-For Sloped slab above 3.60 m ht.Cum13419.8113419.81205.34FalseNoneNoneFalseNoneFalse2755623.78540
3341338117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work-For Forst floor columnCum13474.7413474.749.78FalseNoneNoneFalseNoneFalse131782.95720
3341339117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work-For First floor BeamCum12682.1112682.117.01FalseNoneNoneFalseNoneFalse88901.59110
3341340117397NoneI.No. 2.5.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For First floor slab, OHT worksCum11889.4811889.4854.34FalseNoneNoneFalseNoneFalse646074.34320
3341341117397NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.84130.82FalseNoneNoneFalseNoneFalse13107096.50880
3341342117397NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92805.28FalseNoneNoneFalseNoneFalse239909.01760
3341343117397NoneI.No. 5.5, P.No.9 of PWD SR for Building 2023-24 VProviding and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Foundation in CM 1:6.Sqm7138.887138.88249.99FalseNoneNoneFalseNoneFalse1784648.61120
3341344117397NoneI.No. 5.5, P.No.9 of PWD SR for Building 2023-24 VFirst Floor LevelSqm7210.277210.2710.37FalseNoneNoneFalseNoneFalse74770.49990
3341345117397NoneI.No. 1.4.1, P.No.5 of PWD Common SR 2023-24 Vol- Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 mSqm271.04271.04176.66FalseNoneNoneFalseNoneFalse47881.92640
3341346117397NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesSqm6963.046963.04199.84FalseNoneNoneFalseNoneFalse1391493.91360
3341347117397NoneI.No. 6.32, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1467.21467.2249.71FalseNoneNoneFalseNoneFalse366374.5120
3341348117397NoneI.No. 6.33, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1378.721378.7248.27FalseNoneNoneFalseNoneFalse66550.81440
3341349117397NoneI.No. 6.34, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1236.481236.4815.75FalseNoneNoneFalseNoneFalse19474.560
3341350117397NoneI.No. 11.34B, P.No.86 of PWD SR for Building 2023-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm204.96204.9613738.19FalseNoneNoneFalseNoneFalse2815779.42240
3341351117397NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.922297.09FalseNoneNoneFalseNoneFalse941623.13280
3341352117397NoneI.No. 8.9, P.No.42 of PWD SR for Building 2023-24 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm431.2431.22616.63FalseNoneNoneFalseNoneFalse1128290.8560
3341353117397NoneI.No. 8.1, P.No.43 of PWD SR for Building 2023-24 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm236.32236.322216.88FalseNoneNoneFalseNoneFalse523893.08160
3341354117397NoneI.No. 15.1, P.No.149 of PWD SR for Building 2023-2Polyurethane based Single Component for New Surface :-Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm915.04915.042751.77FalseNoneNoneFalseNoneFalse2517979.62080
3341355117397NoneI.No. 10.7, P.No.69 of PWD SR for Building 2023-24Stone tile (polished) of 8mm thickness granite stone of any color and shade work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/m2 including pointing in white cement complete.Sqm2907.522907.52400.05FalseNoneNoneFalseNoneFalse1163153.3760
3341356117397NoneI.No. 10.18, P.No.71 of PWD SR for Building 2023-2Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.Sqm3762.083762.08134.45FalseNoneNoneFalseNoneFalse505811.6560
3341357117397NoneI.No. 10.2, P.No.69 of PWD SR for Building 2023-24Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.m367.36367.361277.32FalseNoneNoneFalseNoneFalse469236.27520
3341358117397NoneI.No. 10.14, P.No.71 of PWD SR for Building 2023-2Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1238.721238.72543.5FalseNoneNoneFalseNoneFalse673244.320
3341359117397NoneI.No. 9.12.5, P.No.60 of PWD SR for Building 2023-Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. -Size of Tile 600x1200 mmSqm1471.681471.68295.33FalseNoneNoneFalseNoneFalse434631.25440
3341360117397NoneI.No. 9.12.1, P.No.60 of PWD SR for Building 2023-Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. -Size of Tile 500x500 mmSqm1211.841211.8419.51FalseNoneNoneFalseNoneFalse23642.99840
3341361117397NoneI.No. 9.35, P.No.64 of PWD SR for Building 2023-24Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1832.321832.321381.17FalseNoneNoneFalseNoneFalse2530745.41440
3341362117397NoneI.No. 9.23, P.No.63 of PWD SR for Building 2023-24Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub- bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm2761.922761.92469.72FalseNoneNoneFalseNoneFalse1297329.06240
3341363117397NoneI.No. 9.24, P.No.63 of PWD SR for Building 2023-24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3194.243194.2445.6FalseNoneNoneFalseNoneFalse145657.3440
3341364117397NoneI.No. 9.2, P.No.59 of PWD SR for Building 2023-24 Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 ce- ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer inchargeSqm896.0896.019.09FalseNoneNoneFalseNoneFalse17104.640
3341365117397NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm153.44153.443873.25FalseNoneNoneFalseNoneFalse594311.480
3341366117397NoneI.No. 8.33.3, P.No.47 of PWD SR for Building 2023-Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.68155.68518.23FalseNoneNoneFalseNoneFalse80678.04640
3341367117397NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm99.6899.682778.57FalseNoneNoneFalseNoneFalse276967.85760
3341368117397NoneI.No. 12.12, P.No.99 of PWD SR for Building 2023-2Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum14904.2414904.245.26FalseNoneNoneFalseNoneFalse78396.30240
3341369117397NoneI.No. 12.18, P.No.100 of PWD SR for Building 2023-Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm7365.127365.12182.6FalseNoneNoneFalseNoneFalse1344870.9120
3341370117397NoneI.No. 12.93.1, P.No.111 of PWD SR for Building 202Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) -Size 62 x 100mmm786.24786.2430.0FalseNoneNoneFalseNoneFalse23587.20
3341371117397NoneI.No. 12.94.2, P.No.112 of PWD SR for Building 202Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) -35 mm thicknessSqm4525.924525.927.88FalseNoneNoneFalseNoneFalse35664.24960
3341372117397NoneI.No. 12.51, P.No.104 of PWD SR for Building 2023-Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Each1137.921137.9275.0FalseNoneNoneFalseNoneFalse85344.00
3341373117397NoneI.No. 22.15.4, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 300mmNo420.0420.070.0FalseNoneNoneFalseNoneFalse29400.00
3341374117397NoneI.No. 22.15.8, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS hinges 125 mmNo56.056.0327.0FalseNoneNoneFalseNoneFalse18312.00
3341375117397NoneI.No. 22.15.10, P.No.219 of PWD SR for Building 20Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Door stopper 75mmNos112.0112.0109.0FalseNoneNoneFalseNoneFalse12208.00
3341376117397NoneI.No. 22.15.5, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Tower Bolts 150x10mmNo.134.4134.4179.0FalseNoneNoneFalseNoneFalse24057.60
3341377117397NoneI.No. 22.15.1, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Handles 200mmNos504.0504.0179.0FalseNoneNoneFalseNoneFalse90216.00
3341378117397NoneI.No. 12.74.3, P.No.107 of PWD SR for Building 202Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : -75x47x1.80mmNos80.6480.6415.0FalseNoneNoneFalseNoneFalse1209.60
3341379117397NoneI.No. 22.15.3, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 200mmNos336.0336.05.0FalseNoneNoneFalseNoneFalse1680.00
3341380117397NoneI.No. 12.80.2, P.No.108 of PWD SR for Building 202Providing and fixing door latch with necessary screws etc complete. -Oxidised mild steel door latchNos88.4888.4810.0FalseNoneNoneFalseNoneFalse884.80
3341381117397NoneI.No. 12.72, P.No.107 of PWD SR for Building 2023-Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Bar- rel type) with necessary screws etc. complete :Nos91.8491.8410.0FalseNoneNoneFalseNoneFalse918.40
3341382117397NoneI.No. 12.90, P.No.110 of PWD SR for Building 2023-Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possiball fixtures and separate charges for minor T&P's shall not be made)Sqm7542.087542.0870.95FalseNoneNoneFalseNoneFalse535110.5760
3341383117397NoneI.No. 12.86, P.No.109 of PWD SR for Building 2023-Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.Sqm6036.86036.873.31FalseNoneNoneFalseNoneFalse442557.8080
3341384117397NoneI.No. 12.85, P.No.109 of PWD SR for Building 2023-Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mSqm6405.286405.2874.88FalseNoneNoneFalseNoneFalse479627.36640
3341385117397NoneI.No. 22.49, P.No.221 of PWD SR for Building 2023-Providing & fixing upvc ventilator with Exhaust Turbo speed fan with 5 blades (300mm x 300 mm & above sized fan) with copper motor having mounting arrangements as per direction of Engineer in charge of workNos2184.02184.036.0FalseNoneNoneFalseNoneFalse78624.00
3341386117397NoneI.No. 11.6.1, P.No.78 of PWD SR for Building 2023-Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2948.962948.9623.35FalseNoneNoneFalseNoneFalse68858.2160
3341387117397NoneI.No. 11.8.1, P.No.78 of PWD SR for Building 2023-Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 10.00 m² and upto 16.80 m² in the area including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Sqm1105.441105.4423.35FalseNoneNoneFalseNoneFalse25812.0240
3341388117397NoneI.No. 11.3, P.No.77 of PWD SR for Building 2023-24Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm9269.129269.1213.75FalseNoneNoneFalseNoneFalse127450.40
3341389117397NoneI.No. 11.28, P.No.85 of PWD SR for Building 2023-2Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg632.8632.893.42FalseNoneNoneFalseNoneFalse59116.1760
3341390117397NoneI.No. 14.1.1, P.No.131 of PWD SR for Building 2023Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5470.085470.083.0FalseNoneNoneFalseNoneFalse16410.240
3341391117397NoneI.No. 14.3.1, P.No.131 of PWD SR for Building 2023Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : -W.C. pan with ISI marked white solid plastic seat and lidEach6694.246694.242.0FalseNoneNoneFalseNoneFalse13388.480
3341392117397NoneI.No. 14.16A, P.No.134 of PWD SR for Building 2023Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.Each304.64304.645.0FalseNoneNoneFalseNoneFalse1523.20
3341393117397NoneI.No. 14.5.1, P.No.131 of PWD SR for Building 2023Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : -Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach9679.049679.043.0FalseNoneNoneFalseNoneFalse29037.120
3341394117397NoneI.No. 14.43, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT urinal cock of approved quality and colour using 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 g.Each182.56182.563.0FalseNoneNoneFalseNoneFalse547.680
3341395117397NoneI.No. 10.8, P.No.70 of PWD SR for Building 2023-24Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm3123.683123.683.6FalseNoneNoneFalseNoneFalse11245.2480
3341396117397NoneI.No. 14.7.2, P.No.132 of PWD SR for Building 2023Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: -White Vitreous China Wash basin size 630x450 mm with a single 15 mmC.P. brass pillar tapEach2868.322868.3220.0FalseNoneNoneFalseNoneFalse57366.40
3341397117397NoneI.No. 14.32.2, P.No.136 of PWD SR for Building 202Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : -Rectangular shape 453x357 mmEach1140.161140.165.0FalseNoneNoneFalseNoneFalse5700.80
3341398117397NoneI.No. 14.40.2, P.No.137 of PWD SR for Building 202Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. -600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each555.52555.525.0FalseNoneNoneFalseNoneFalse2777.60
3341399117397NoneI.No. 14.41, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 g.Each562.24562.246.0FalseNoneNoneFalseNoneFalse3373.440
3341400117397NoneI.No. 13.17.3, P.No.120 of PWD SR for Building 202Providing and fixing PTMT bib cock of approved quality and colour. -15 mm nominal bore, 165 mm long, weighing not less than 110 gEach249.76249.7650.0FalseNoneNoneFalseNoneFalse12488.00
3341401117397NoneI.No. 13.3.2, P.No.117 of PWD SR for Building 2023Providing and fixing brass stop cock of approved quality : -20 mm nominal borEach341.6341.630.0FalseNoneNoneFalseNoneFalse10248.00
3341402117397NoneI.No. 13.4.1, P.No.117 of PWD SR for Building 2023roviding and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : -25 mm nominal boreEach614.88614.8830.0FalseNoneNoneFalseNoneFalse18446.40
3341403117397NoneI.No. 13.4.4, P.No.117 of PWD SR for Building 2023Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : -50 mm nominal boreEach957.6957.610.0FalseNoneNoneFalseNoneFalse9576.00
3341404117397NoneI.No. 13.5.3, P.No.117 of PWD SR for Building 2023Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : -25 mm nominal boreEach371.84371.8415.0FalseNoneNoneFalseNoneFalse5577.60
3341405117397NoneI.No. 13.22.2, P.No.120 of PWD SR for Building 202Providing and fixing PTMT grating of approved quality and colour. -Rectangular type with openable circular lidEach226.24226.2430.0FalseNoneNoneFalseNoneFalse6787.20
3341406117397NoneS.R.I.No.16.9, P.191, of SR Vol-5 Water supply andConstructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverNos6108.486108.4812.0FalseNoneNoneFalseNoneFalse73301.760
3341407117397NoneI.No. 13.48, P.No.125 of PWD SR for Building 2023-Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterNos325.92325.9260.0FalseNoneNoneFalseNoneFalse19555.20
3341408117397NoneS.R.I.No.9.1.4, P.95, of SR Vol-5 Water supply andProviding, laying and jointing HDPE pipes of specified grade andco nforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0: HDPE Grade PE80-PN6.0,110mm diam198.24198.24190.0FalseNoneNoneFalseNoneFalse37665.60
3341409117397NoneI.No. 13.50.6, P.No.125 of PWD SR for Building 202Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -50 mm nominal dia Pipesm432.32432.32456.0FalseNoneNoneFalseNoneFalse197137.920
3341410117397NoneS.R.I.No.16.7.4, P.191, of SR Vol-5 Water supply aProviding and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipesm16.6816.6880.0FalseNoneNoneFalseNoneFalse1334.40
3341411117397NoneI.No. 13.50.4, P.No.125 of PWD SR for Building 202Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -32 mm nominal dia Pipesm304.64304.64328.0FalseNoneNoneFalseNoneFalse99921.920
3341412117397NoneI.No. 13.32.3, P.No.122 of PWD SR for Building 202Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. -25 mm nominal dia pipesm534.24534.24328.0FalseNoneNoneFalseNoneFalse175230.720
3341413117397NoneI.No. 13.32.2, P.No.122 of PWD SR for Building 202Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. -20 mm nominal dia pipesm424.48424.4890.0FalseNoneNoneFalseNoneFalse38203.20
3341414117397NoneI.No. 15.14, P.No.152 of PWD SR for Building 2023-GT/OHT (inside) waterproofing with Anti-microbial Coating :-Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coatinSqm1873.761873.76139.45FalseNoneNoneFalseNoneFalse261295.8320
3341415117397NoneI.No. 7.3, P.No.83 of SR Water supply and SewerageProviding and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved pint etc. complete including all lead and lifts etc.Each2396.82396.82.0FalseNoneNoneFalseNoneFalse4793.60
3341416117397NoneI.No. 7.1.2, P.No.83 of SR Water supply and SeweraProviding and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mmm5377.125377.127.0FalseNoneNoneFalseNoneFalse37639.840
3341417117397NoneI.No. 18.6, P.No.184 of PWD SR for Building 2023-2Providing and supplying Spandrel Glass PanelsSqm2217.62217.616.98FalseNoneNoneFalseNoneFalse37654.8480
3341418117397NoneI.No. 11.44, P.No.91 of PWD SR for Building 2023-2Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4866.44866.421.0FalseNoneNoneFalseNoneFalse102194.40
3341419117397NoneI.No. 7.56, P.No.34 of PWD SR for Building 2023-24Providing & Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Plain T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers.Sqm2233.282233.28104.5FalseNoneNoneFalseNoneFalse233377.760
3341420117397NoneI.No. 8.16.2, P.No.43 of PWD SR for Building 2023-Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment -Plaster mesh 150mm widSqm42.5642.562016.0FalseNoneNoneFalseNoneFalse85800.960
17192950820000NoneNoneOther Works07 FISHERMEN GEAR SHEDS2285399.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341421117398NoneI.No. , P.No.8 of PWD Common SR 2023-24 Vol- IEarth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum106.4106.45.18FalseNoneNoneFalseNoneFalse551.1520
3341422117398NoneI.No. 2.1.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.683.89FalseNoneNoneFalseNoneFalse26092.87520
3341423117398NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.92577.08FalseNoneNoneFalseNoneFalse236556.63360
3341424117398NoneI.No. 8.9, P.No.42 of PWD SR for Building 2023-24 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm431.2431.2345.44FalseNoneNoneFalseNoneFalse148953.7280
3341425117398NoneI.No. 9.2, P.No.59 of PWD SR for Building 2023-24 Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 ce- ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge.Sqm896.0896.0478.035FalseNoneNoneFalseNoneFalse428319.360
3341426117398NoneI.No. 15.1, P.No.149 of PWD SR for Building 2023-2Polyurethane based Single Component for New Surface :-Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm915.04915.04318.25FalseNoneNoneFalseNoneFalse291211.480
3341427117398NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm153.44153.442307.87FalseNoneNoneFalseNoneFalse354119.57280
3341428117398NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm99.6899.68518.17FalseNoneNoneFalseNoneFalse51651.18560
3341429117398NoneI.No. 12.12, P.No.99 of PWD SR for Building 2023-2Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum14904.2414904.241.47FalseNoneNoneFalseNoneFalse21909.23280
3341430117398NoneI.No. 12.51, P.No.104 of PWD SR for Building 2023-Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1137.921137.9236.0FalseNoneNoneFalseNoneFalse40965.120
3341431117398NoneI.No. 12.18, P.No.100 of PWD SR for Building 2023-Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm7365.127365.1281.18FalseNoneNoneFalseNoneFalse597900.44160
3341432117398NoneI.No. 22.15.4, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 300mmNos420.0420.018.0FalseNoneNoneFalseNoneFalse7560.00
3341433117398NoneI.No. 22.15.8, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS hinges 125 mmNos56.056.054.0FalseNoneNoneFalseNoneFalse3024.00
3341434117398NoneI.No. 22.15.10, P.No.219 of PWD SR for Building 20Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Door stopper 75mmSqm112.0112.018.0FalseNoneNoneFalseNoneFalse2016.00
3341435117398NoneI.No. 22.15.5, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Tower Bolts 150x10mmSqm134.4134.436.0FalseNoneNoneFalseNoneFalse4838.40
3341436117398NoneI.No. 22.15.1, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Handles 200mmSqm504.0504.036.0FalseNoneNoneFalseNoneFalse18144.00
3341437117398NoneI.No. 8.33.3, P.No.47 of PWD SR for Building 2023-Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.68155.6897.2FalseNoneNoneFalseNoneFalse15132.0960
3341438117398NoneI.No. 8.33.2, P.No.46 of PWD SR for Building 2023-Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm154.56154.56235.86FalseNoneNoneFalseNoneFalse36454.52160
17192950820001NoneNoneOther Works08 NET MENDING SHEDS - 03 No.10551122.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341439117399NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.24757.11FalseNoneNoneFalseNoneFalse86492.24640
3341440117399NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.84110.61FalseNoneNoneFalseNoneFalse332254.74240
3341441117399NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.6869.8FalseNoneNoneFalseNoneFalse442788.8640
3341442117399NoneI.No. 2.2.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-including form work-For FootingCum7664.037664.0377.16FalseNoneNoneFalseNoneFalse591356.55480
3341443117399NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work- For Column pedastalCum12063.7412063.747.08FalseNoneNoneFalseNoneFalse85411.27920
3341444117399NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.6872.33FalseNoneNoneFalseNoneFalse517570.33440
3341445117399NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92369.45FalseNoneNoneFalseNoneFalse110066.5440
3341446117399NoneI.No. 1.11, P.No.7 of PWD Common SR 2023-24 Vol- IFilling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto1.5 m.Cum484.96484.96344.83FalseNoneNoneFalseNoneFalse167228.75680
3341447117399NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work- For ColumnCum13029.0713029.0713.54FalseNoneNoneFalseNoneFalse176413.60780
3341448117399NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work- For BeamsCum11496.2411496.2466.02FalseNoneNoneFalseNoneFalse758981.76480
3341449117399NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work- For Sloped Roof SlabCum13029.0713029.07117.26FalseNoneNoneFalseNoneFalse1527788.74820
3341450117399NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.849.64FalseNoneNoneFalseNoneFalse965849.33760
3341451117399NoneI.No. 5.7, P.No.9 of PWD SR for Building 2023-24 VProviding and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.Cum7565.67565.648.33FalseNoneNoneFalseNoneFalse365645.4480
3341452117399NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.921242.0FalseNoneNoneFalseNoneFalse509120.640
3341453117399NoneI.No. 8.1, P.No.43 of PWD SR for Building 2023-24 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm236.32236.32960.0FalseNoneNoneFalseNoneFalse226867.20
3341454117399NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm153.44153.444404.0FalseNoneNoneFalseNoneFalse675749.760
3341455117399NoneI.No. 9.2, P.No.59 of PWD SR for Building 2023-24 Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 ce- ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge.Cum896.0896.01719.9FalseNoneNoneFalseNoneFalse1541030.40
3341456117399NoneI.No. 15.1, P.No.149 of PWD SR for Building 2023-2Polyurethane based Single Component for New Surface :-Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Cum915.04915.041607.04FalseNoneNoneFalseNoneFalse1470505.88160
17192950820001NoneNoneOther Works09 FISHERMEN SHEDS - 04 No10602478.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341457117400NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.24296.48FalseNoneNoneFalseNoneFalse33869.87520
3341458117400NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.8449.89FalseNoneNoneFalseNoneFalse149861.57760
3341459117400NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.6828.74FalseNoneNoneFalseNoneFalse182317.36320
3341460117400NoneI.No. 2.2.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For FootingCum7805.957805.9532.15FalseNoneNoneFalseNoneFalse250961.29250
3341461117400NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- Column PedestalCum12063.7412063.741.89FalseNoneNoneFalseNoneFalse22800.46860
3341462117400NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.6840.62FalseNoneNoneFalseNoneFalse290663.72160
3341463117400NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92237.52FalseNoneNoneFalseNoneFalse70761.95840
3341464117400NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For ColumnCum13029.0713029.073.73FalseNoneNoneFalseNoneFalse48598.43110
3341465117400NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Plinth BeamCum11496.2411496.247.66FalseNoneNoneFalseNoneFalse88061.19840
3341466117400NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Lintel and BeamCum12262.6612262.6616.64FalseNoneNoneFalseNoneFalse204050.66240
3341467117400NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Chejja Cum11113.0311113.038.71FalseNoneNoneFalseNoneFalse96794.49130
3341468117400NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For SlabCum11496.2411496.2436.67FalseNoneNoneFalseNoneFalse421567.12080
3341469117400NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.8411.67FalseNoneNoneFalseNoneFalse1169238.77280
3341470117400NoneI.No. 5.7, P.No.9 of PWD SR for Building 2023-24 VProviding and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.Cum7565.67565.640.53FalseNoneNoneFalseNoneFalse306633.7680
3341471117400NoneI.No. 6.33, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1378.721378.72130.0FalseNoneNoneFalseNoneFalse179233.60
3341472117400NoneI.No. 6.34, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1236.481236.48123.2FalseNoneNoneFalseNoneFalse152334.3360
3341473117400NoneI.No. 11.34B, P.No.86 of PWD SR for Building 2023-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etcSqm204.96204.961757.7FalseNoneNoneFalseNoneFalse360258.1920
3341474117400NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesSqm6963.046963.0482.3FalseNoneNoneFalseNoneFalse573058.1920
3341475117400NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.92901.07FalseNoneNoneFalseNoneFalse369366.61440
3341476117400NoneI.No. 8.9, P.No.42 of PWD SR for Building 2023-24 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm431.2431.2747.99FalseNoneNoneFalseNoneFalse322533.2880
3341477117400NoneI.No. 8.1, P.No.43 of PWD SR for Building 2023-24 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge.Sqm236.32236.32489.16FalseNoneNoneFalseNoneFalse115598.29120
3341478117400NoneI.No. 9.12.5, P.No.60 of PWD SR for Building 2023-Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. -Size of Tile 600x1200 mmSqm1471.681471.68873.8FalseNoneNoneFalseNoneFalse1285953.9840
3341479117400NoneI.No. 9.9, P.No.60 of PWD SR for Building 2023-24 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.Sqm1205.121205.1251.84FalseNoneNoneFalseNoneFalse62473.42080
3341480117400NoneI.No. 10.14, P.No.71 of PWD SR for Building 2023-2Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1238.721238.72353.96FalseNoneNoneFalseNoneFalse438457.33120
3341481117400NoneI.No. 12.12, P.No.99 of PWD SR for Building 2023-2Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum14904.2414904.240.29FalseNoneNoneFalseNoneFalse4322.22960
3341482117400NoneI.No. 12.18, P.No.100 of PWD SR for Building 2023-Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm7365.127365.1210.08FalseNoneNoneFalseNoneFalse74240.40960
3341483117400NoneI.No. 12.93.1, P.No.111 of PWD SR for Building 202Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) -Size 62 x 100mmm786.24786.24171.2FalseNoneNoneFalseNoneFalse134604.2880
3341484117400NoneI.No. 12.94.2, P.No.112 of PWD SR for Building 202Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) -35 mm thicknessSqm4525.924525.9245.92FalseNoneNoneFalseNoneFalse207830.24640
3341485117400NoneI.No. 12.51, P.No.104 of PWD SR for Building 2023-Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Sqm1137.921137.9240.0FalseNoneNoneFalseNoneFalse45516.80
3341486117400NoneI.No. 22.15.4, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 300mmNos420.0420.08.0FalseNoneNoneFalseNoneFalse3360.00
3341487117400NoneI.No. 22.15.8, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS hinges 125 mmNos56.056.024.0FalseNoneNoneFalseNoneFalse1344.00
3341488117400NoneI.No. 22.15.10, P.No.219 of PWD SR for Building 20Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Door stopper 75mmNos112.0112.04.0FalseNoneNoneFalseNoneFalse448.00
3341489117400NoneI.No. 22.15.5, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Tower Bolts 150x10mmNos134.4134.412.0FalseNoneNoneFalseNoneFalse1612.80
3341490117400NoneI.No. 22.15.1, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Handles 200mmNos504.0504.08.0FalseNoneNoneFalseNoneFalse4032.00
3341491117400NoneS.R.I.No.12.58, P.107, Vol-2 PWD SR 2021-22 continProviding and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos122.08122.084.0FalseNoneNoneFalseNoneFalse488.320
3341492117400NoneI.No. 12.74.3, P.No.107 of PWD SR for Building 202Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : -75x47x1.80mmNos80.6480.6464.0FalseNoneNoneFalseNoneFalse5160.960
3341493117400NoneI.No. 22.15.3, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 200mmNos336.0336.032.0FalseNoneNoneFalseNoneFalse10752.00
3341494117400NoneI.No. 12.80.2, P.No.108 of PWD SR for Building 202roviding and fixing door latch with necessary screws etc complete. -Oxidised mild steel door latchNos88.4888.4832.0FalseNoneNoneFalseNoneFalse2831.360
3341495117400NoneI.No. 12.72, P.No.107 of PWD SR for Building 2023-Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Bar- rel type) with necessary screws etc. complete :Nos91.8491.8464.0FalseNoneNoneFalseNoneFalse5877.760
3341496117400NoneI.No. 12.86, P.No.109 of PWD SR for Building 2023-Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated and reinforced with Galvanized Iron profile through-out the window frame.Nos6036.86036.864.8FalseNoneNoneFalseNoneFalse391184.640
3341497117400NoneI.No. 12.85, P.No.109 of PWD SR for Building 2023-Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Nos6405.286405.2821.6FalseNoneNoneFalseNoneFalse138354.0480
3341498117400NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Nos153.44153.442241.52FalseNoneNoneFalseNoneFalse343938.82880
3341499117400NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Nos99.6899.681495.98FalseNoneNoneFalseNoneFalse149119.28640
3341500117400NoneI.No. 8.33.3, P.No.47 of PWD SR for Building 2023-Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.68155.68167.4FalseNoneNoneFalseNoneFalse26060.8320
3341501117400NoneI.No. 8.33.2, P.No.46 of PWD SR for Building 2023-Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Nos154.56154.5626.2FalseNoneNoneFalseNoneFalse4049.4720
3341502117400NoneI.No. 15.1, P.No.149 of PWD SR for Building 2023-2Polyurethane based Single Component for New Surface :-Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Nos915.04915.04980.92FalseNoneNoneFalseNoneFalse897581.03680
3341503117400NoneI.No. 14.1.1, P.No.131 of PWD SR for Building 2023Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5470.085470.088.0FalseNoneNoneFalseNoneFalse43760.640
3341504117400NoneI.No. 14.3.1, P.No.131 of PWD SR for Building 2023oviding and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : -W.C. pan with ISI marked white solid plastic seat and lidEach6694.246694.248.0FalseNoneNoneFalseNoneFalse53553.920
3341505117400NoneI.No. 14.16A, P.No.134 of PWD SR for Building 2023Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.Each304.64304.6416.0FalseNoneNoneFalseNoneFalse4874.240
3341506117400NoneI.No. 14.5.1, P.No.131 of PWD SR for Building 2023Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : -Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach9679.049679.0416.0FalseNoneNoneFalseNoneFalse154864.640
3341507117400NoneI.No. 14.43, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT urinal cock of approved quality and colour using 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 g.Each182.56182.5616.0FalseNoneNoneFalseNoneFalse2920.960
3341508117400NoneI.No. 14.7.2, P.No.132 of PWD SR for Building 2023Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: -White Vitreous China Wash basin size 630x450 mm with a single 15 mmC.P. brass pillar tapEach2868.322868.3212.0FalseNoneNoneFalseNoneFalse34419.840
3341509117400NoneI.No. 14.32.2, P.No.136 of PWD SR for Building 202Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : -Rectangular shape 453x357 mmEach1140.161140.1612.0FalseNoneNoneFalseNoneFalse13681.920
3341510117400NoneI.No. 14.40.2, P.No.137 of PWD SR for Building 202Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. -600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each555.52555.5224.0FalseNoneNoneFalseNoneFalse13332.480
3341511117400NoneI.No. 14.41, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 g.Each562.24562.2412.0FalseNoneNoneFalseNoneFalse6746.880
3341512117400NoneI.No. 13.34, P.No.123 of PWD SR for Building 2023-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr10.0810.084000.0FalseNoneNoneFalseNoneFalse40320.00
3341513117400NoneI.No. 13.17.3, P.No.120 of PWD SR for Building 202Providing and fixing PTMT bib cock of approved quality and colour. -15 mm nominal bore, 165 mm long, weighing not less than 110 gEach249.76249.7640.0FalseNoneNoneFalseNoneFalse9990.40
3341514117400NoneI.No. 13.3.2, P.No.117 of PWD SR for Building 2023Providing and fixing brass stop cock of approved quality : -20 mm nominal boreEach341.6341.616.0FalseNoneNoneFalseNoneFalse5465.60
3341515117400NoneI.No. 13.4.2, P.No.117 of PWD SR for Building 2023Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : -32 mm nominal boreEach669.76669.7612.0FalseNoneNoneFalseNoneFalse8037.120
3341516117400NoneI.No. 13.5.2, P.No.117 of PWD SR for Building 2023Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : -20 mm nominal boreNos351.68351.684.0FalseNoneNoneFalseNoneFalse1406.720
3341517117400NoneI.No. 13.22.2, P.No.120 of PWD SR for Building 202Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidEach226.24226.2432.0FalseNoneNoneFalseNoneFalse7239.680
3341518117400NoneI.No. 13.25, P.No.121 of PWD SR for Building 2023-Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gmsNos163.52163.5216.0FalseNoneNoneFalseNoneFalse2616.320
3341519117400NoneS.R.I.No.16.9, P.191, of SR Vol-5 Water supply andConstructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverNos6108.486108.484.0FalseNoneNoneFalseNoneFalse24433.920
3341520117400NoneI.No. 13.48, P.No.125 of PWD SR for Building 2023-Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterm325.92325.9240.0FalseNoneNoneFalseNoneFalse13036.80
3341521117400NoneI.No. 10.8, P.No.70 of PWD SR for Building 2023-24Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.m3123.683123.688.64FalseNoneNoneFalseNoneFalse26988.59520
3341522117400NoneS.R.I.No.9.1.4, P.95, of SR Vol-5 Water supply andProviding, laying and jointing HDPE pipes of specified grade andco nforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0: HDPE Grade PE80-PN6.0,110mm diam198.24198.24120.0FalseNoneNoneFalseNoneFalse23788.80
3341523117400NoneI.No. 13.50.4, P.No.125 of PWD SR for Building 202Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -32 mm nominal dia PipesNos304.64304.64180.0FalseNoneNoneFalseNoneFalse54835.20
3341524117400NoneI.No. 13.32.2, P.No.122 of PWD SR for Building 202Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. -20 mm nominal dia pipesNos424.48424.4848.0FalseNoneNoneFalseNoneFalse20375.040
3341525117400NoneS.R.I.No.16.7.4, P.191, of SR Vol-5 Water supply aProviding and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:m155.68155.68160.0FalseNoneNoneFalseNoneFalse24908.80
3341526117400NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.2477.15FalseNoneNoneFalseNoneFalse8813.6160
3341527117400NoneS.R.I.No. 12.5, P.5, Vol-5 PWD SR 2021-22 continProviding and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. -140mm(weight of pipe -2.131 kg)Rmtr449.12449.1244.5FalseNoneNoneFalseNoneFalse19985.840
3341528117400NoneI.No. 2.1.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.682.0FalseNoneNoneFalseNoneFalse13415.360
3341529117400NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7096.327096.3215.19FalseNoneNoneFalseNoneFalse107793.10080
3341530117400NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.841.46FalseNoneNoneFalseNoneFalse146280.08640
3341531117400NoneI.No. 6.32, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1467.21467.245.28FalseNoneNoneFalseNoneFalse66434.8160
17192950820001NoneNoneOther Works11 RESTAURANTS - 02 No8038696.88
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341532117401NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.24352.8FalseNoneNoneFalseNoneFalse40303.8720
3341533117401NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.8477.02FalseNoneNoneFalseNoneFalse231355.75680
3341534117401NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.6825.85FalseNoneNoneFalseNoneFalse163984.1280
3341535117401NoneI.No. 2.2.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including form work- For FootingCum7664.037664.0336.44FalseNoneNoneFalseNoneFalse279277.25320
3341536117401NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Including Form work- For Column PedestalCum12063.7412063.741.81FalseNoneNoneFalseNoneFalse21835.36940
3341537117401NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.6845.46FalseNoneNoneFalseNoneFalse325297.21280
3341538117401NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92176.4FalseNoneNoneFalseNoneFalse52553.0880
3341539117401NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For ColumnCum13029.0713029.075.21FalseNoneNoneFalseNoneFalse67881.45470
3341540117401NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For PlinthCum11496.2411496.246.89FalseNoneNoneFalseNoneFalse79209.09360
3341541117401NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Beam and LintelCum12262.6612262.6616.0FalseNoneNoneFalseNoneFalse196202.560
3341542117401NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For SlabCum11113.0311113.0345.22FalseNoneNoneFalseNoneFalse502531.21660
3341543117401NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For ChejjaCum11496.2411496.245.68FalseNoneNoneFalseNoneFalse65298.64320
3341544117401NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.8417.74FalseNoneNoneFalseNoneFalse1777403.24160
3341545117401NoneI.No. 5.7, P.No.9 of PWD SR for Building 2023-24 VProviding and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.Cum7565.67565.634.12FalseNoneNoneFalseNoneFalse258138.2720
3341546117401NoneI.No. 6.33, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1378.721378.72227.52FalseNoneNoneFalseNoneFalse313686.37440
3341547117401NoneI.No. 6.34, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1236.481236.4881.74FalseNoneNoneFalseNoneFalse101069.87520
3341548117401NoneI.No. 11.34B, P.No.86 of PWD SR for Building 2023-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm204.96204.961125.18FalseNoneNoneFalseNoneFalse230616.89280
3341549117401NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesSqm6963.046963.0457.06FalseNoneNoneFalseNoneFalse397311.06240
3341550117401NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.921027.78FalseNoneNoneFalseNoneFalse421307.57760
3341551117401NoneI.No. 8.9, P.No.42 of PWD SR for Building 2023-24 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm431.2431.2627.64FalseNoneNoneFalseNoneFalse270638.3680
3341552117401NoneI.No. 8.1, P.No.43 of PWD SR for Building 2023-24 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm236.32236.32348.48FalseNoneNoneFalseNoneFalse82352.79360
3341553117401NoneI.No. 9.12.5, P.No.60 of PWD SR for Building 2023-Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. -Size of Tile 600x1200 mmSqm1471.681471.68197.8FalseNoneNoneFalseNoneFalse291098.3040
3341554117401NoneI.No. 9.9, P.No.60 of PWD SR for Building 2023-24 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., completeSqm1205.121205.1233.38FalseNoneNoneFalseNoneFalse40226.90560
3341555117401NoneI.No. 10.14, P.No.71 of PWD SR for Building 2023-2Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1238.721238.7265.23FalseNoneNoneFalseNoneFalse80801.70560
3341556117401NoneI.No. 10.1.2, P.No.69 of PWD SR for Building 2023-Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. -Area of slab over 0.50 m2Sqm4409.444409.4414.25FalseNoneNoneFalseNoneFalse62834.520
3341557117401NoneI.No. 10.2, P.No.69 of PWD SR for Building 2023-24Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Sqm367.36367.3618.2FalseNoneNoneFalseNoneFalse6685.9520
3341558117401NoneI.No. 12.12, P.No.99 of PWD SR for Building 2023-2Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum14904.2414904.240.343FalseNoneNoneFalseNoneFalse5112.154320
3341559117401NoneI.No. 12.18, P.No.100 of PWD SR for Building 2023-Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm7365.127365.1212.6FalseNoneNoneFalseNoneFalse92800.5120
3341560117401NoneI.No. 12.93.1, P.No.111 of PWD SR for Building 202Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) -Size 62 x 100mmm786.24786.2469.3FalseNoneNoneFalseNoneFalse54486.4320
3341561117401NoneI.No. 12.94.2, P.No.112 of PWD SR for Building 202Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) -35 mm thicknessNos4525.924525.9222.05FalseNoneNoneFalseNoneFalse99796.5360
3341562117401NoneI.No. 12.51, P.No.104 of PWD SR for Building 2023-Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1137.921137.926.0FalseNoneNoneFalseNoneFalse6827.520
3341563117401NoneI.No. 22.15.4, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 300mmNos420.0420.06.0FalseNoneNoneFalseNoneFalse2520.00
3341564117401NoneI.No. 22.15.8, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS hinges 125 mmNos56.056.018.0FalseNoneNoneFalseNoneFalse1008.00
3341565117401NoneI.No. 22.15.10, P.No.219 of PWD SR for Building 20Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Door stopper 75mmNos112.0112.06.0FalseNoneNoneFalseNoneFalse672.00
3341566117401NoneI.No. 22.15.5, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Tower Bolts 150x10mmNos134.4134.412.0FalseNoneNoneFalseNoneFalse1612.80
3341567117401NoneI.No. 22.15.1, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Handles 200mmNos504.0504.012.0FalseNoneNoneFalseNoneFalse6048.00
3341568117401NoneI.No. 12.74.3, P.No.107 of PWD SR for Building 202Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : -75x47x1.80mmNos80.6480.6442.0FalseNoneNoneFalseNoneFalse3386.880
3341569117401NoneI.No. 22.15.3, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 200mmNos336.0336.014.0FalseNoneNoneFalseNoneFalse4704.00
3341570117401NoneI.No. 12.80.2, P.No.108 of PWD SR for Building 202Providing and fixing door latch with necessary screws etc complete. -Oxidised mild steel door latchNos88.4888.4814.0FalseNoneNoneFalseNoneFalse1238.720
3341571117401NoneI.No. 12.72, P.No.107 of PWD SR for Building 2023-roviding and fixing ISI marked oxidised M.S. tower bolt black finish, (Bar- rel type) with necessary screws etc. complete :Nos91.8491.8428.0FalseNoneNoneFalseNoneFalse2571.520
3341572117401NoneI.No. 12.86, P.No.109 of PWD SR for Building 2023-Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.Nos6036.86036.840.5FalseNoneNoneFalseNoneFalse244490.40
3341573117401NoneI.No. 12.85, P.No.109 of PWD SR for Building 2023-Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frameNos6405.286405.2813.08FalseNoneNoneFalseNoneFalse83781.06240
3341574117401NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Nos153.44153.441329.7FalseNoneNoneFalseNoneFalse204029.1680
3341575117401NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm99.6899.68627.64FalseNoneNoneFalseNoneFalse62563.15520
3341576117401NoneI.No. 8.33.3, P.No.47 of PWD SR for Building 2023-Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.68155.6853.58FalseNoneNoneFalseNoneFalse8341.33440
3341577117401NoneI.No. 8.33.2, P.No.46 of PWD SR for Building 2023-Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Nos154.56154.5619.66FalseNoneNoneFalseNoneFalse3038.64960
3341578117401NoneI.No. 14.3.1, P.No.131 of PWD SR for Building 2023Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : -W.C. pan with ISI marked white solid plastic seat and lidEach6694.246694.248.0FalseNoneNoneFalseNoneFalse53553.920
3341579117401NoneI.No. 14.23, P.No.135 of PWD SR for Building 2023-Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : -Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach9679.049679.044.0FalseNoneNoneFalseNoneFalse38716.160
3341580117401NoneI.No. 14.43, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT urinal cock of approved quality and colour using 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 g.Each182.56182.564.0FalseNoneNoneFalseNoneFalse730.240
3341581117401NoneI.No. 14.7.1, P.No.132 of PWD SR for Building 2023Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: -White Vitreous China Wash basin size 630x450 mm with a pair of 15 mmC.P. brass pillar tapsEach3451.843451.8412.0FalseNoneNoneFalseNoneFalse41422.080
3341582117401NoneI.No. 14.10.1.2, P.No.133 of PWD SR for Building 2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board -510x1040 mm bowl depth 225 mmEach6040.166040.162.0FalseNoneNoneFalseNoneFalse12080.320
3341583117401NoneI.No. 14.32.2, P.No.136 of PWD SR for Building 202Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : -Rectangular shape 453x357 mmEach1140.161140.168.0FalseNoneNoneFalseNoneFalse9121.280
3341584117401NoneI.No. 14.40.2, P.No.137 of PWD SR for Building 202Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. -600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each555.52555.5212.0FalseNoneNoneFalseNoneFalse6666.240
3341585117401NoneI.No. 14.41, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 g.Each562.24562.2412.0FalseNoneNoneFalseNoneFalse6746.880
3341586117401NoneI.No. 14.16A, P.No.134 of PWD SR for Building 2023Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.Each304.64304.648.0FalseNoneNoneFalseNoneFalse2437.120
3341587117401NoneI.No. 13.34, P.No.123 of PWD SR for Building 2023-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.0810.086000.0FalseNoneNoneFalseNoneFalse60480.00
3341588117401NoneI.No. 13.17.3, P.No.120 of PWD SR for Building 202Providing and fixing PTMT bib cock of approved quality and colour. -15 mm nominal bore, 165 mm long, weighing not less than 110 gNos249.76249.7616.0FalseNoneNoneFalseNoneFalse3996.160
3341589117401NoneI.No. 13.3.2, P.No.117 of PWD SR for Building 2023Providing and fixing brass stop cock of approved quality : -20 mm nominal boreNos341.6341.66.0FalseNoneNoneFalseNoneFalse2049.60
3341590117401NoneI.No. 13.4.2, P.No.117 of PWD SR for Building 2023Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : -32 mm nominal boreNos669.76669.766.0FalseNoneNoneFalseNoneFalse4018.560
3341591117401NoneI.No. 13.5.2, P.No.117 of PWD SR for Building 2023Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : -20 mm nominal borNos351.68351.684.0FalseNoneNoneFalseNoneFalse1406.720
3341592117401NoneI.No. 13.20 a, P.No.120 of PWD SR for Building 202Providing and fixing PTMT Sink cock of approved quality andcolour 15 mm nominal bore, weighing not less than 130 g.Nos291.2291.24.0FalseNoneNoneFalseNoneFalse1164.80
3341593117401NoneI.No. 13.22.2, P.No.120 of PWD SR for Building 202Providing and fixing PTMT grating of approved quality and colour. -Rectangular type with openable circular lidNos226.24226.248.0FalseNoneNoneFalseNoneFalse1809.920
3341594117401NoneI.No. 13.25, P.No.121 of PWD SR for Building 2023-Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gmsNos163.52163.524.0FalseNoneNoneFalseNoneFalse654.080
3341595117401NoneI.No. 13.55.1, P.No.127 of PWD SR for Building 202Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc.complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay (non modular) bricks of class designation 3.5-Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size With common burnt clay (non modular) bricks of class designation 3.5Nos7215.047215.044.0FalseNoneNoneFalseNoneFalse28860.160
3341596117401NoneI.No. 13.48, P.No.125 of PWD SR for Building 2023-Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterRmtr325.92325.9218.0FalseNoneNoneFalseNoneFalse5866.560
3341597117401NoneS.R.I.No.9.1.4, P.95, of SR Vol-5 Water supply andProviding, laying and jointing HDPE pipes of specified grade andco nforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0: HDPE Grade PE80-PN6.0,110mm diaRmtr198.24198.2450.0FalseNoneNoneFalseNoneFalse9912.00
3341598117401NoneI.No. 13.50.4, P.No.125 of PWD SR for Building 202Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -32 mm nominal dia PipesRmtr304.64304.64139.6FalseNoneNoneFalseNoneFalse42527.7440
3341599117401NoneI.No. 13.32.2, P.No.122 of PWD SR for Building 202Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. -20 mm nominal dia pipesRmtr424.48424.4860.0FalseNoneNoneFalseNoneFalse25468.80
3341600117401NoneI.No. 13.32.3, P.No.122 of PWD SR for Building 202Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. -25 mm nominal dia pipesRmtr534.24534.2424.0FalseNoneNoneFalseNoneFalse12821.760
3341601117401NoneS.R.I.No.16.7.4, P.191, of SR Vol-5 Water supply aProviding and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:Rmtr155.68155.6820.0FalseNoneNoneFalseNoneFalse3113.60
3341602117401NoneI.No. 22.49, P.No.221 of PWD SR for Building 2023-Providing & fixing upvc ventilator with Exhaust Turbo speed fan with 5 blades (300mm x 300 mm & above sized fan) with copper motor having mounting arrangements as per direction of Engineer in charge of workNos2184.02184.08.0FalseNoneNoneFalseNoneFalse17472.00
3341603117401NoneI.No. 15.1, P.No.149 of PWD SR for Building 2023-2Polyurethane based Single Component for New Surface :-Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm915.04915.04433.5FalseNoneNoneFalseNoneFalse396669.840
17192950820000NoneNoneOther Works12 RCC SLOPPING HARD - 03 Nos19947561.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341604117402NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.243811.8FalseNoneNoneFalseNoneFalse435460.0320
3341605117402NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.924417.92FalseNoneNoneFalseNoneFalse1316186.72640
3341606117402NoneI.No. 2.4.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work- For Guide wallCum9560.389560.3814.04FalseNoneNoneFalseNoneFalse134227.73520
3341607117402NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.84405.91FalseNoneNoneFalseNoneFalse1219288.69440
3341608117402NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Retainung wallCum8683.698683.69614.21FalseNoneNoneFalseNoneFalse5333609.23490
3341609117402NoneS.R.I.No. 1.2, P.7, Vol-7 PWD SR 2021-22 continuProviding and placing in situ reinforced cement concrete of M35 grade using tremie pipe for diaphragm wall / Anchor wall of 600mm thick including Boring / Excavation through all strata except hard rock to the requisite specified depth and using mechanical equipments including charges towards retaining the sides from collapsing using bentonite mud circulation and disposing of the excavated materials etc.,Sqm14728.014728.0384.0FalseNoneNoneFalseNoneFalse5655552.00
3341610117402NoneI.No. 2.11.h., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - For Other structureMT88492.3288492.3256.73FalseNoneNoneFalseNoneFalse5020169.31360
3341611117402NoneI.No. 19.3, P.No.187 of PWD SR for Building 2023-2Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2717.122717.1298.64FalseNoneNoneFalseNoneFalse268016.71680
3341612117402NoneS.R.I.No. 12.2, P.117, of PWD SR for Roads and BrProviding weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with PVC Pipe 110mm outer dia at 2 kg per m2, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical SpecificationsNos267.68267.68498.0FalseNoneNoneFalseNoneFalse133304.640
3341613117402NoneS.R.I.No. 12.4, P.117, of PWD SR for Roads and BrProviding and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.Cum2998.242998.24144.0FalseNoneNoneFalseNoneFalse431746.560
17192950820001NoneNoneOther Works13 COMPOUND WALL12961008.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341614117403NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.241038.36FalseNoneNoneFalseNoneFalse118622.24640
3341615117403NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.6891.62FalseNoneNoneFalseNoneFalse581207.96160
3341616117403NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.68515.36FalseNoneNoneFalseNoneFalse3687751.24480
3341617117403NoneI.No. 5.7, P.No.9 of PWD SR for Building 2023-24 VProviding and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.Cum7565.67565.6668.3FalseNoneNoneFalseNoneFalse5056090.480
3341618117403NoneI.No. 2.4.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7081.767081.7669.48FalseNoneNoneFalseNoneFalse492040.68480
3341619117403NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.926063.69FalseNoneNoneFalseNoneFalse2485627.80480
3341620117403NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm89.089.06063.69FalseNoneNoneFalseNoneFalse539668.410
17192950820000NoneNoneOther Works14 PUBLIC TOILET BUILDING5419124.88
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341621117404NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.24216.52FalseNoneNoneFalseNoneFalse24735.24480
3341622117404NoneI.No. 1.4.1, P.No.5 of PWD Common SR 2023-24 Vol- Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 mCum271.04271.0442.92FalseNoneNoneFalseNoneFalse11633.03680
3341623117404NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.8442.9FalseNoneNoneFalseNoneFalse128864.7360
3341624117404NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.6825.75FalseNoneNoneFalseNoneFalse163349.760
3341625117404NoneI.No. 2.4.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7081.767081.767.72FalseNoneNoneFalseNoneFalse54671.18720
3341626117404NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7157.687157.6899.57FalseNoneNoneFalseNoneFalse712690.19760
3341627117404NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92148.62FalseNoneNoneFalseNoneFalse44276.87040
3341628117404NoneI.No. 5.5, P.No.9 of PWD SR for Building 2023-24 VProviding and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Foundation in CM 1:6.Cum7138.887138.8868.8FalseNoneNoneFalseNoneFalse491154.9440
3341629117404NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.842.45FalseNoneNoneFalseNoneFalse245470.0080
3341630117404NoneI.No. 6.34, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1236.481236.48112.14FalseNoneNoneFalseNoneFalse138658.86720
3341631117404NoneI.No. 11.34B, P.No.86 of PWD SR for Building 2023-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm204.96204.96499.32FalseNoneNoneFalseNoneFalse102340.62720
3341632117404NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.92560.35FalseNoneNoneFalseNoneFalse229698.6720
3341633117404NoneI.No. 8.9, P.No.42 of PWD SR for Building 2023-24 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm431.2431.2315.99FalseNoneNoneFalseNoneFalse136254.8880
3341634117404NoneI.No. 8.1, P.No.43 of PWD SR for Building 2023-24 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm236.32236.32243.56FalseNoneNoneFalseNoneFalse57558.09920
3341635117404NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6963.046963.048.2FalseNoneNoneFalseNoneFalse57096.9280
3341636117404NoneI.No. 9.12.2, P.No.60 of PWD SR for Building 2023-Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. -Size of Tile 600x600 mmSqm1282.41282.499.56FalseNoneNoneFalseNoneFalse127675.7440
3341637117404NoneI.No. 9.11, P.No.60 of PWD SR for Building 2023-24Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm995.68995.6839.6FalseNoneNoneFalseNoneFalse39428.9280
3341638117404NoneI.No. 10.14, P.No.71 of PWD SR for Building 2023-2Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1238.721238.72374.33FalseNoneNoneFalseNoneFalse463690.05760
3341639117404NoneI.No. 10.8, P.No.70 of PWD SR for Building 2023-24Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm3123.683123.6812.6FalseNoneNoneFalseNoneFalse39358.3680
3341640117404NoneI.No. 10.1.2, P.No.69 of PWD SR for Building 2023-Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. -Area of slab over 0.50 m2Sqm4409.444409.443.825FalseNoneNoneFalseNoneFalse16866.1080
3341641117404NoneI.No. 10.4, P.No.69 of PWD SR for Building 2023-24Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.Sqm661.92661.926.0FalseNoneNoneFalseNoneFalse3971.520
3341642117404NoneI.No. 12.12, P.No.99 of PWD SR for Building 2023-2Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum14904.2414904.240.109FalseNoneNoneFalseNoneFalse1624.562160
3341643117404NoneI.No. 12.18, P.No.100 of PWD SR for Building 2023-Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm7365.127365.125.04FalseNoneNoneFalseNoneFalse37120.20480
3341644117404NoneI.No. 12.93.1, P.No.111 of PWD SR for Building 202Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) -Size 62 x 100mmm786.24786.24153.0FalseNoneNoneFalseNoneFalse120294.720
3341645117404NoneI.No. 12.94.2, P.No.112 of PWD SR for Building 202Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) -35 mm thicknessSqm4525.924525.9247.25FalseNoneNoneFalseNoneFalse213849.720
3341646117404NoneI.No. 12.51, P.No.104 of PWD SR for Building 2023-Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1137.921137.9232.0FalseNoneNoneFalseNoneFalse36413.440
3341647117404NoneI.No. 22.15.4, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 300mmNo420.0420.04.0FalseNoneNoneFalseNoneFalse1680.00
3341648117404NoneI.No. 22.15.8, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS hinges 125 mmEach56.056.012.0FalseNoneNoneFalseNoneFalse672.00
3341649117404NoneI.No. 22.15.10, P.No.219 of PWD SR for Building 20Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Door stopper 75mmNos112.0112.02.0FalseNoneNoneFalseNoneFalse224.00
3341650117404NoneI.No. 22.15.5, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Tower Bolts 150x10mmNos134.4134.48.0FalseNoneNoneFalseNoneFalse1075.20
3341651117404NoneI.No. 22.15.1, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Handles 200mmNos504.0504.04.0FalseNoneNoneFalseNoneFalse2016.00
3341652117404NoneI.No. 12.74.3, P.No.107 of PWD SR for Building 202Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : -75x47x1.80mmNos80.6480.6490.0FalseNoneNoneFalseNoneFalse7257.60
3341653117404NoneI.No. 22.15.3, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 200mmNos336.0336.030.0FalseNoneNoneFalseNoneFalse10080.00
3341654117404NoneI.No. 12.80.2, P.No.108 of PWD SR for Building 202Providing and fixing door latch with necessary screws etc complete. -Oxidised mild steel door latchNos.88.4888.4860.0FalseNoneNoneFalseNoneFalse5308.80
3341655117404NoneI.No. 12.72, P.No.107 of PWD SR for Building 2023-Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Bar- rel type) with necessary screws etc. complete :Nos91.8491.8460.0FalseNoneNoneFalseNoneFalse5510.40
3341656117404NoneI.No. 12.86, P.No.109 of PWD SR for Building 2023-Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.Sqm6036.86036.814.58FalseNoneNoneFalseNoneFalse88016.5440
3341657117404NoneI.No. 12.85, P.No.109 of PWD SR for Building 2023-Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame.Sqm6405.286405.2811.7FalseNoneNoneFalseNoneFalse74941.7760
3341658117404NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm153.44153.44981.63FalseNoneNoneFalseNoneFalse150621.30720
3341659117404NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm99.6899.68315.99FalseNoneNoneFalseNoneFalse31497.88320
3341660117404NoneI.No. 8.33.3, P.No.47 of PWD SR for Building 2023-Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.68155.6826.28FalseNoneNoneFalseNoneFalse4091.27040
3341661117404NoneI.No. 8.33.2, P.No.46 of PWD SR for Building 2023-Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm154.56154.5613.1FalseNoneNoneFalseNoneFalse2024.7360
3341662117404NoneI.No. 15.1, P.No.149 of PWD SR for Building 2023-2Polyurethane based Single Component for New Surface :-Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm915.04915.04247.98FalseNoneNoneFalseNoneFalse226911.61920
3341663117404NoneI.No. 14.1.1, P.No.131 of PWD SR for Building 2023Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5470.085470.0810.0FalseNoneNoneFalseNoneFalse54700.80
3341664117404NoneI.No. 14.3.1, P.No.131 of PWD SR for Building 2023Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : -W.C. pan with ISI marked white solid plastic seat and lidEach6694.246694.248.0FalseNoneNoneFalseNoneFalse53553.920
3341665117404NoneI.No. 14.16A, P.No.134 of PWD SR for Building 2023Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.Each304.64304.6414.0FalseNoneNoneFalseNoneFalse4264.960
3341666117404NoneI.No. 14.4.1, P.No.131 of PWD SR for Building 2023Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : -Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach9679.049679.0416.0FalseNoneNoneFalseNoneFalse154864.640
3341667117404NoneI.No. 14.43, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT urinal cock of approved quality and colour using 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 g.Each182.56182.566.0FalseNoneNoneFalseNoneFalse1095.360
3341668117404NoneI.No. 14.7.2, P.No.132 of PWD SR for Building 2023Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: -White Vitreous China Wash basin size 630x450 mm with a single 15 mmC.P. brass pillar tapEach2868.322868.326.0FalseNoneNoneFalseNoneFalse17209.920
3341669117404NoneI.No. 14.32.2, P.No.136 of PWD SR for Building 202Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : -Rectangular shape 453x357 mmEach1140.161140.166.0FalseNoneNoneFalseNoneFalse6840.960
3341670117404NoneI.No. 14.40.2, P.No.137 of PWD SR for Building 202Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. -600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each555.52555.5212.0FalseNoneNoneFalseNoneFalse6666.240
3341671117404NoneI.No. 14.41, P.No.138 of PWD SR for Building 2023-Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 g.Each562.24562.2418.0FalseNoneNoneFalseNoneFalse10120.320
3341672117404NoneI.No. 13.34, P.No.123 of PWD SR for Building 2023-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.0810.084000.0FalseNoneNoneFalseNoneFalse40320.00
3341673117404NoneI.No. 13.17.3, P.No.120 of PWD SR for Building 202Providing and fixing PTMT bib cock of approved quality and colour. -15 mm nominal bore, 165 mm long, weighing not less than 110 gEach249.76249.7625.0FalseNoneNoneFalseNoneFalse6244.00
3341674117404NoneI.No. 13.3.2, P.No.117 of PWD SR for Building 2023Providing and fixing brass stop cock of approved quality : -20 mm nominal boreEach341.6341.68.0FalseNoneNoneFalseNoneFalse2732.80
3341675117404NoneI.No. 13.4.2, P.No.117 of PWD SR for Building 2023Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : -32 mm nominal boreEach669.76669.764.0FalseNoneNoneFalseNoneFalse2679.040
3341676117404NoneI.No. 13.5.2, P.No.117 of PWD SR for Building 2023Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : -20 mm nominal boreNos351.68351.686.0FalseNoneNoneFalseNoneFalse2110.080
3341677117404NoneI.No. 13.22.2, P.No.120 of PWD SR for Building 202Providing and fixing PTMT grating of approved quality and colour. -Rectangular type with openable circular lidEach226.24226.2425.0FalseNoneNoneFalseNoneFalse5656.00
3341678117404NoneI.No. 13.25, P.No.121 of PWD SR for Building 2023-Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gmsNos163.52163.5210.0FalseNoneNoneFalseNoneFalse1635.20
3341679117404NoneI.No. 13.48, P.No.125 of PWD SR for Building 2023-Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterRmtr325.92325.9230.0FalseNoneNoneFalseNoneFalse9777.60
3341680117404NoneS.R.I.No.16.9, P.191, of SR Vol-5 Water supply andonstructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverNos6108.486108.486.0FalseNoneNoneFalseNoneFalse36650.880
3341681117404NoneS.R.I.No.9.1.4, P.95, of SR Vol-5 Water supply andProviding, laying and jointing HDPE pipes of specified grade andco nforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0: HDPE Grade PE80-PN6.0,110mm diam198.24198.2440.0FalseNoneNoneFalseNoneFalse7929.60
3341682117404NoneI.No. 13.50.4, P.No.125 of PWD SR for Building 202Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -32 mm nominal dia PipesNos304.64304.64100.0FalseNoneNoneFalseNoneFalse30464.00
3341683117404NoneI.No. 13.32.2, P.No.122 of PWD SR for Building 202Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. -20 mm nominal dia pipesNos424.48424.48101.0FalseNoneNoneFalseNoneFalse42872.480
3341684117404NoneS.R.I.No.16.7.4, P.191, of SR Vol-5 Water supply aProviding and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:m155.68155.6840.0FalseNoneNoneFalseNoneFalse6227.20
3341685117404NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For BeamCum12262.6612262.668.99FalseNoneNoneFalseNoneFalse110241.31340
3341686117404NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For ChejjaCum11113.0311113.030.79FalseNoneNoneFalseNoneFalse8779.29370
3341687117404NoneI.No. 2.5.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Sloped SLabCum13029.0713029.0737.21FalseNoneNoneFalseNoneFalse484811.69470
17192950820000NoneNoneOther Works15 SECURITY HOUSE WITH GATE2600346.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341688117405NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.24156.6FalseNoneNoneFalseNoneFalse17889.9840
3341689117405NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.8427.4FalseNoneNoneFalseNoneFalse82305.2160
3341690117405NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.6823.96FalseNoneNoneFalseNoneFalse151994.57280
3341691117405NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.6818.21FalseNoneNoneFalseNoneFalse130304.93280
3341692117405NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92118.86FalseNoneNoneFalseNoneFalse35410.77120
3341693117405NoneI.No. 2.4.2, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7081.767081.760.5FalseNoneNoneFalseNoneFalse3540.880
3341694117405NoneI.No. 2.2.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For FootingCum7664.037664.036.08FalseNoneNoneFalseNoneFalse46597.30240
3341695117405NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.6827.64FalseNoneNoneFalseNoneFalse197782.99520
3341696117405NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For ColumnCum12063.7412063.747.66FalseNoneNoneFalseNoneFalse92408.24840
3341697117405NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For BeamCum11354.1111354.118.72FalseNoneNoneFalseNoneFalse99007.83920
3341698117405NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Sloped Slab Cum12063.7412063.7428.1FalseNoneNoneFalseNoneFalse338991.0940
3341699117405NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.843.18FalseNoneNoneFalseNoneFalse318610.05120
3341700117405NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm409.92409.92168.4FalseNoneNoneFalseNoneFalse69030.5280
3341701117405NoneI.No. 8.9, P.No.42 of PWD SR for Building 2023-24 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm431.2431.2292.08FalseNoneNoneFalseNoneFalse125944.8960
3341702117405NoneI.No. 11.34B, P.No.86 of PWD SR for Building 2023-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Kg204.96204.96323.2FalseNoneNoneFalseNoneFalse66243.0720
3341703117405NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm153.44153.44214.46FalseNoneNoneFalseNoneFalse32906.74240
3341704117405NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm99.6899.68606.42FalseNoneNoneFalseNoneFalse60447.94560
3341705117405NoneI.No. 12.12, P.No.99 of PWD SR for Building 2023-2Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum14904.2414904.240.16FalseNoneNoneFalseNoneFalse2384.67840
3341706117405NoneI.No. 12.18, P.No.100 of PWD SR for Building 2023-Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm7365.127365.127.56FalseNoneNoneFalseNoneFalse55680.30720
3341707117405NoneI.No. 12.51, P.No.104 of PWD SR for Building 2023-Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1137.921137.924.0FalseNoneNoneFalseNoneFalse4551.680
3341708117405NoneI.No. 22.15.4, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 300mmSqm420.0420.08.0FalseNoneNoneFalseNoneFalse3360.00
3341709117405NoneI.No. 22.15.8, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS hinges 125 mm Sqm56.056.012.0FalseNoneNoneFalseNoneFalse672.00
3341710117405NoneI.No. 22.15.10, P.No.219 of PWD SR for Building 20Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Door stopper 75mmNos112.0112.08.0FalseNoneNoneFalseNoneFalse896.00
3341711117405NoneI.No. 22.15.5, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Tower Bolts 150x10mmNos134.4134.416.0FalseNoneNoneFalseNoneFalse2150.40
3341712117405NoneI.No. 22.15.1, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Handles 200mmNos504.0504.08.0FalseNoneNoneFalseNoneFalse4032.00
3341713117405NoneI.No. 12.86, P.No.109 of PWD SR for Building 2023-viding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.Sqm6036.86036.815.4FalseNoneNoneFalseNoneFalse92966.720
3341714117405NoneI.No. 8.33.3, P.No.47 of PWD SR for Building 2023-Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.68155.68270.78FalseNoneNoneFalseNoneFalse42155.03040
3341715117405NoneI.No. 8.33.2, P.No.46 of PWD SR for Building 2023-Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm154.56154.569.82FalseNoneNoneFalseNoneFalse1517.77920
3341716117405NoneI.No. 11.1, P.No.77 of PWD SR for Building 2023-24Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg118.72118.723000.0FalseNoneNoneFalseNoneFalse356160.00
3341717117405NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesKg6963.046963.044.62FalseNoneNoneFalseNoneFalse32169.24480
3341718117405NoneI.No. 9.12.5, P.No.60 of PWD SR for Building 2023-Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. -Size of Tile 600x1200 mmKg1471.681471.6857.7FalseNoneNoneFalseNoneFalse84915.9360
3341719117405NoneI.No. 6.33, P.No.17 of PWD SR for Building 2023-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Kg1378.721378.7234.32FalseNoneNoneFalseNoneFalse47317.67040
17192950820001NoneNoneOther Works18 ELECTRIC POWER SUPPLY AND DISTRIBUTION8847954.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341720117406Nonecode01Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014, 250 kVA, Aluminium Wdg, Star 2 (5 StarNo1023432.481023432.481.0FalseNoneNoneFalseNoneFalse1023432.480
3341721117406Nonecode02Prefabricated Platform for erection of 250 kVA Transformer on 11 Mtr Spun Pole Structure involving Rectangular hollow Sections 96x48x4.87 Thk and 66x3x4.5 Thk, Circular hollow section of 165.6 OD x 10 Thk , MS Stiffner plate 12 mm Thk, MS plate Base Plate 16 mm Thk, J Blots 12 mm dia, Gusset Plates, Clamps,15 mm rods 2.5 Mtr length as per drawing details. Tor Steel Rods cut of Dia 8 mm,10 mm,12 mm,16 mm and 20 mm bent as per drawing & tied inclusive of labour for Reinforced foundation(Dwg No. BESCOM/GM/QS&S/70 Dtd 24.11.2018.No59492.1659492.161.0FalseNoneNoneFalseNoneFalse59492.160
3341722117406Nonecode03Load Break Switch with PanelUnit82576.4882576.481.0FalseNoneNoneFalseNoneFalse82576.480
3341723117406Nonecode0411 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018Unit272688.64272688.641.0FalseNoneNoneFalseNoneFalse272688.640
3341724117406Nonecode05LT Protection Kit(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018.No2265.762265.761.0FalseNoneNoneFalseNoneFalse2265.760
3341725117406Nonecode06LT Distribution Box for 250 kVA DTC with MCCB's (Sheet Metal)(Dwg No. BESCOM/GM/QS&S/08 Dtd 24.11.2018)No25551.6825551.681.0FalseNoneNoneFalseNoneFalse25551.680
3341726117406Nonecode07kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)No1030.41030.43.0FalseNoneNoneFalseNoneFalse3091.20
3341727117406Nonecode0811 kV, HG Fuse Unit with Solid Core Insulator(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018.Set1197.281197.281.0FalseNoneNoneFalseNoneFalse1197.280
3341728117406Nonecode09Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977.Set25230.2325230.231.0FalseNoneNoneFalseNoneFalse25230.230
3341729117406Nonecode1011 kV, 400 Amps Single Break Polymer Type Post Insulators GOSSet15374.2415374.241.0FalseNoneNoneFalseNoneFalse15374.240
3341730117406Nonecode11H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI. COMMON Electrical SR of 2023-24Set20870.0820870.081.0FalseNoneNoneFalseNoneFalse20870.080
3341731117406Nonecode1211 kV, DOLO Cutout Conventional to Erstwhile KEB Specification.Set6580.06580.01.0FalseNoneNoneFalseNoneFalse6580.00
3341732117406Nonecode13Heat Shrinkable Indoor Type Cable Termination Kit for PILC Cable.Set3514.563514.566.0FalseNoneNoneFalseNoneFalse21087.360
3341733117406Nonecode14Heat Shrinkable Outdoor Type Cable Termination Kit for PILC Cable.Set4555.044555.044.0FalseNoneNoneFalseNoneFalse18220.160
3341734117406Nonecode15Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.48600000.0FalseNoneNoneFalseNoneFalse288000.00
3341735117406Nonecode16Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.830.0FalseNoneNoneFalseNoneFalse82824.00
3341736117406Nonecode17Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )250 A 4 x 30 x 10 mm Aluminium Stripsm3847.23847.28.0FalseNoneNoneFalseNoneFalse30777.60
3341737117406Nonecode18Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.430.0FalseNoneNoneFalseNoneFalse13272.00
3341738117406Nonecode19Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )250 AEach24399.224399.22.0FalseNoneNoneFalseNoneFalse48798.40
3341739117406Nonecode20Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100A to 250A TPDT/COSEach527.52527.522.0FalseNoneNoneFalseNoneFalse1055.040
3341740117406Nonecode21Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each10432.810432.81.0FalseNoneNoneFalseNoneFalse10432.80
3341741117406Nonecode22Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) -FOUR Pole -100 A 25 kAEach9505.449505.4460.0FalseNoneNoneFalseNoneFalse570326.40
3341742117406Nonecode23Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) -FOUR Pole -250 A 36 kAEach26370.426370.414.0FalseNoneNoneFalseNoneFalse369185.60
3341743117406Nonecode24Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each10365.610365.61.0FalseNoneNoneFalseNoneFalse10365.60
3341744117406Nonecode25Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each10432.810432.81.0FalseNoneNoneFalseNoneFalse10432.80
3341745117406Nonecode26Supplying and fixing of Shunt trip suitable for MCCB.CBCT..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each1907.361907.361.0FalseNoneNoneFalseNoneFalse1907.360
3341746117406Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.1250.0FalseNoneNoneFalseNoneFalse1456.00
3341747117406Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.0460.0FalseNoneNoneFalseNoneFalse2822.40
3341748117406Nonecode29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.5680.0FalseNoneNoneFalseNoneFalse5644.80
3341749117406Nonecode30Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmmm103.03103.0360.0FalseNoneNoneFalseNoneFalse6181.80
3341750117406Nonecode31Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )3C x 2.5 mm2m126.56126.5660.0FalseNoneNoneFalseNoneFalse7593.60
3341751117406Nonecode32Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975 -16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Km132164.48132164.480.6FalseNoneNoneFalseNoneFalse79298.6880
3341752117406Nonecode33Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975,-95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km418000.8418000.81.0FalseNoneNoneFalseNoneFalse418000.80
3341753117406Nonecode34Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975, 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)Km966185.92966185.921.0FalseNoneNoneFalseNoneFalse966185.920
3341754117406Nonecode35Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work...( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 )Cum542.08542.0843.2FalseNoneNoneFalseNoneFalse23417.8560
3341755117406Nonecode36Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications..( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 ) -Labour charges Rs,Cum179.2179.243.2FalseNoneNoneFalseNoneFalse7741.440
3341756117406Nonecode37Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,,.3x95 to 150 SqmmKm68680.6468680.640.15FalseNoneNoneFalseNoneFalse10302.0960
3341757117406Nonecode38Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,,.LT Cable 2.5 to 25 SqmmKm23392.3223392.320.6FalseNoneNoneFalseNoneFalse14035.3920
3341758117406Nonecode39Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,,.LT Cable 35 to 95 SqmmKm34875.6834875.681.0FalseNoneNoneFalseNoneFalse34875.680
3341759117406Nonecode40Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,,.LT Cable120 to 240 SqmmKm36151.3636151.361.0FalseNoneNoneFalseNoneFalse36151.360
3341760117406Nonecode41GI Pipe -40 mm DiaMtr280.0280.030.0FalseNoneNoneFalseNoneFalse8400.00
3341761117406Nonecode42GI Pipe -65 mm DiaMtr519.68519.6830.0FalseNoneNoneFalseNoneFalse15590.40
3341762117406Nonecode43Supplying of Cable gland ,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mmEach88.4888.4830.0FalseNoneNoneFalseNoneFalse2654.40
3341763117406Nonecode44Supplying of Cable gland ,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )45 mmEach220.64220.6440.0FalseNoneNoneFalseNoneFalse8825.60
3341764117406Nonecode45Supplying of Haevy Duty Copper Terminal Long Barrel,.25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.2430.0FalseNoneNoneFalseNoneFalse907.20
3341765117406Nonecode46Supplying of Haevy Duty Copper Terminal Long Barrel,.95 Sqmm Copper Terminal, Apprx Wt: 64 GmNo144.48144.4830.0FalseNoneNoneFalseNoneFalse4334.40
3341766117406Nonecode47Supplying of Haevy Duty Copper Terminal Long Barrel,.240 Sqmm Copper Terminal, Apprx Wt: 218 GmNo397.6397.6120.0FalseNoneNoneFalseNoneFalse47712.00
3341767117406Nonecode4811 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975.-95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1258884.481258884.480.15FalseNoneNoneFalseNoneFalse188832.6720
3341768117406Nonecode49Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges. Material cost Rs.Set5850.885850.8830.0FalseNoneNoneFalseNoneFalse175526.40
3341769117406Nonecode50Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges Labour charges Rs,Set2364.322364.3230.0FalseNoneNoneFalseNoneFalse70929.60
3341770117406Nonecode51Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractor..m375.2375.2800.0FalseNoneNoneFalseNoneFalse300160.00
3341771117406Nonecode52Fabrication, Supplying, Erection, Testing and Commissioning of ...... ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data.,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 20 m - Top 150 mm and Bottom 460 mm diaEach274400.0274400.04.0FalseNoneNoneFalseNoneFalse1097600.00
3341772117406Nonecode53Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 200WEach20810.7220810.7224.0FalseNoneNoneFalseNoneFalse499457.280
3341773117406Nonecode54Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975, - Materials cost Rs.Km158863.04158863.040.2FalseNoneNoneFalseNoneFalse31772.6080
3341774117406Nonecode55Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 to 25 SqmmKm23392.3223392.320.2FalseNoneNoneFalseNoneFalse4678.4640
3341775117406Nonecode56Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.2432.0FalseNoneNoneFalseNoneFalse967.680
3341776117406Nonecode57Brass Cable Gland 25 mmNo88.4888.488.0FalseNoneNoneFalseNoneFalse707.840
3341777117406Nonecode58Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.6812.0FalseNoneNoneFalseNoneFalse9932.160
3341778117406Nonecode59Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.274.0FalseNoneNoneFalseNoneFalse13637.080
3341779117406Nonecode60Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40 AEach6853.286853.284.0FalseNoneNoneFalseNoneFalse27413.120
3341780117406Nonecode61Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each5424.165424.164.0FalseNoneNoneFalseNoneFalse21696.640
3341781117406Nonecode62Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.812.0FalseNoneNoneFalseNoneFalse6921.60
3341782117406Nonecode63Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.4812000.0FalseNoneNoneFalseNoneFalse5760.00
3341783117406Nonecode64Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.82.0FalseNoneNoneFalseNoneFalse5521.60
3341784117406Nonecode65Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.416.0FalseNoneNoneFalseNoneFalse7078.40
3341785117406Nonecode66Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges. Maerial cost Rs.Set5850.885850.884.0FalseNoneNoneFalseNoneFalse23403.520
3341786117406Nonecode67Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges. Labour charges Rs,Set2364.322364.324.0FalseNoneNoneFalseNoneFalse9457.280
3341787117406Nonecode68Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractor..m375.2375.220.0FalseNoneNoneFalseNoneFalse7504.00
3341788117406Nonecode69Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )9 m - Top 70 mm and Bottom 155 mm diaEach21840.021840.035.0FalseNoneNoneFalseNoneFalse764400.00
3341789117406Nonecode70Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Single Arm Bracket with 2000 mm Standard 40/50 mm diaEach2912.02912.035.0FalseNoneNoneFalseNoneFalse101920.00
3341790117406Nonecode71Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED Streetlight 90 WEach9923.29923.235.0FalseNoneNoneFalseNoneFalse347312.00
3341791117406Nonecode72Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975, 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Km158863.04158863.041.4FalseNoneNoneFalseNoneFalse222408.2560
3341792117406Nonecode73Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 to 25 SqmmKm23392.3223392.321.4FalseNoneNoneFalseNoneFalse32749.2480
3341793117406Nonecode74Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.24320.0FalseNoneNoneFalseNoneFalse9676.80
3341794117406Nonecode75Brass Cable Gland. 25 mmNo88.4888.4880.0FalseNoneNoneFalseNoneFalse7078.40
3341795117406Nonecode76Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.689.0FalseNoneNoneFalseNoneFalse7449.120
3341796117406Nonecode77Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.273.0FalseNoneNoneFalseNoneFalse10227.810
3341797117406Nonecode78Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40 AEach6853.286853.283.0FalseNoneNoneFalseNoneFalse20559.840
3341798117406Nonecode79Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each5424.165424.163.0FalseNoneNoneFalseNoneFalse16272.480
3341799117406Nonecode80Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.89.0FalseNoneNoneFalseNoneFalse5191.20
3341800117406Nonecode81Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.4890000.0FalseNoneNoneFalseNoneFalse43200.00
3341801117406Nonecode82Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.81.5FalseNoneNoneFalseNoneFalse4141.20
3341802117406Nonecode83Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.412.0FalseNoneNoneFalseNoneFalse5308.80
3341803117406Nonecode84Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges. Maerial cost Rs.Set5850.885850.882.0FalseNoneNoneFalseNoneFalse11701.760
3341804117406Nonecode85Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges. Labour charges Rs,Set2364.322364.322.0FalseNoneNoneFalseNoneFalse4728.640
3341805117406Nonecode86Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractor.m375.2375.220.0FalseNoneNoneFalseNoneFalse7504.00
17192950820001NoneNoneOther Works19 FRESH WATER STORAGE SUPPLY/DISTRIBUTION WITH OHT8235012.48
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341806117407NoneI.No. 11.38, P.No.113 of SR 20223-24 Vol-III Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. - 600 mm Dia pile-OHTRmtr7591.537591.5380.0FalseNoneNoneFalseNoneFalse607322.40
3341807117407NoneI.No. 11.37, P.No.113 of SR 20223-24 Vol-III RoadsProviding Steel Liner 10 mm thick for Curbs and 6 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing.-OHTt140474.88140474.882.13FalseNoneNoneFalseNoneFalse299211.49440
3341808117407NoneI.No. 1.14.1, P.No.8 of PWD SR 2023-24 Vol- IEarth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 m-OHTt114.24114.2419.53FalseNoneNoneFalseNoneFalse2231.10720
3341809117407NoneI.No. 2.1.4, P.No.15 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-OHTCum6963.046963.042.79FalseNoneNoneFalseNoneFalse19426.88160
3341810117407NoneI.No. 2.4.4, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For Pile cap BeamCum12081.6612081.6613.39FalseNoneNoneFalseNoneFalse161773.42740
3341811117407NoneI.No. 2.5.3, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work-OHT Column up to 3.60 m htCum13341.3313341.332.92FalseNoneNoneFalseNoneFalse38956.68360
3341812117407NoneI.No. 2.4.3, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work - OHT -Column up to 3.60 m to 6.60 m htCum13419.8113419.812.43FalseNoneNoneFalseNoneFalse32610.13830
3341813117407NoneI.No. 2.5.3, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work- 6.60 m to 9.50 m ht-OHTCum13498.2913498.292.35FalseNoneNoneFalseNoneFalse31720.98150
3341814117407NoneI.No. 2.5.3, P.No.16 of PWD SR 2023-24 Vol- Iroviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work- Tie BeamCum13200.0613200.063.89FalseNoneNoneFalseNoneFalse51348.23340
3341815117407NoneI.No. 2.5.3, P.No.16 of PWD SR 2023-24 Vol- Iroviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work-OHT Bottom BeamCum13278.5413278.5415.76FalseNoneNoneFalseNoneFalse209269.79040
3341816117407NoneI.No. 2.5.3, P.No.16 of PWD SR 2023-24 Vol- Iroviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work-OHT Bottom SlabCum12399.5912399.5911.98FalseNoneNoneFalseNoneFalse148547.08820
3341817117407NoneI.No. 2.5.3, P.No.16 of PWD SR 2023-24 Vol- Iroviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work-OHT Side wallCum12791.9812791.9825.33FalseNoneNoneFalseNoneFalse324020.85340
3341818117407NoneI.No. 2.5.3, P.No.16 of PWD SR 2023-24 Vol- Iroviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Including Form work-OHT TOp SlabCum12870.4512870.456.61FalseNoneNoneFalseNoneFalse85073.67450
3341819117407NoneI.No. 2.11.a., P.No.18 of PWD SR 2023-24 Vol- ISteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -Other Structuret84492.3284492.326.07FalseNoneNoneFalseNoneFalse512868.38240
3341820117407NoneI.No. 2.11.a., P.No.18 of PWD SR 2023-24 Vol- ISteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -Other Structure- OHT above 3.50 m htt91147.0991147.096.55FalseNoneNoneFalseNoneFalse597013.43950
3341821117407NoneI.No. 15.14, P.No.152 of PWD SR for Building 2023-UGT/OHT (inside) waterproofing with Anti-microbial Coating-OHTSqm1873.761873.76115.58FalseNoneNoneFalseNoneFalse216569.18080
3341822117407NoneI.No. 7.1.2, P.No.85 of SR 20223-24 Vol-IV Water sProviding and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:: MS angle of 65 x 65 x 10mm-OHTm5377.125377.1223.5FalseNoneNoneFalseNoneFalse126362.320
3341823117407NoneI.No. 7.3, P.No.85 of SR 20223-24 Vol-IV Water supProviding and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved pint etc. complete including all lead and lifts etc.FOR OHTEach2396.82396.82.0FalseNoneNoneFalseNoneFalse4793.60
3341824117407NoneI.No. 7.4.3, P.No.85 of SR 20223-24 Vol-IV Water sProviding and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick, 0.23 M width with copper floats indicators and flexible nylone wires, painting figures with approved enamel paint etc. with all lead and lifts, complete for: Enamelled guage plate for 2.5 m depth-OHTEach6672.966672.961.0FalseNoneNoneFalseNoneFalse6672.960
3341825117407NoneI.No. 7.4.4, P.No.85 of SR 20223-24 Vol-IV Extra for enamelled guage plate for every 0.5 m beyond 2.5 m depth-OHTEach1216.321216.322.0FalseNoneNoneFalseNoneFalse2432.640
3341826117407NoneI.No. 7.5.3, P.No.86 of SR 20223-24 Vol-IV Water sSupplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . - For DI/CI puddle flanges of 150mm dia.-OHTEach2653.282653.287.0FalseNoneNoneFalseNoneFalse18572.960
3341827117407NoneI.No. 7.6.3, P.No.87 of SR 20223-24 Vol-IV Water Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete.: For double flanged CI pipes of 150mm dia.-OHTm5384.965384.9653.0FalseNoneNoneFalseNoneFalse285402.880
3341828117407NoneI.No. 7.7.4, P.No.87 of SR 20223-24 Vol-IV Water sSupplying and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for: For Over Head Tanks upto 15m stagingEach15555.6815555.681.0FalseNoneNoneFalseNoneFalse15555.680
3341829117407NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-OHTSqm99.6899.68325.0FalseNoneNoneFalseNoneFalse32396.00
3341830117407NoneI.No. 7.8, P.No.88 of SR 20223-24 Vol-IV Water supSupplying and fixing 40mm dia. GI pipe medium duty pipes hand railing 3 rows fixed to RCC 1:2:4 vibrated post of 150x150mm at bottom and 100x150mm at top, placed at 2 Mtrs. intervals for a height of 750mm including curing, painting GI pipes with two coats of anticorrosive steel paint over a primer coat etc. with all lead lift etc. (The rate per meter is for 3 rows of GI pipes and RCC post)-OHTm1486.241486.2423.0FalseNoneNoneFalseNoneFalse34183.520
3341831117407NoneI.No. 7.9.2, P.No.87 of SR 20223-24 Vol-IV Water sSupplying, of DI flanged pipe conforming to IS 8329 : 2000 with latest amendments with Cement Mortar Lining (CML) with Portland Slag Cement as per IS 455:1989 and Metallic Zinc Coating as per annexure A of IS 8329 with finishing layer of Bituminous Coating as per Annex C of IS 8329 and Flanges: Metallic zinc rich epoxy paint & Bituminous Coating, laying true to line and hoisting in position and aligning to correct plumb including cost of jointing material, conveying to work spot with all lead and lifts etc., complete. For PN 10: - 150mm-OHTm7431.27431.215.0FalseNoneNoneFalseNoneFalse111468.00
3341832117407NoneI.No. 7.11.3, P.No.88 of SR 20223-24 Vol-IVSuppling Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends:- 150 X 90 -OHTEach5781.445781.445.0FalseNoneNoneFalseNoneFalse28907.20
3341833117407NoneI.No. 7.12, P.No.88 of SR 20223-24 Vol-IV Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M-15) bed for embedding the ladder bottom complete-OHTEach5712.05712.05.0FalseNoneNoneFalseNoneFalse28560.00
3341834117407NoneI.No. 1.17.1, P.No.10 of PWD SR 2023-24 Vol- IEarth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m-OHTCum293.44293.44862.5FalseNoneNoneFalseNoneFalse253092.00
3341835117407NoneI.No. 13.50.7, P.No.125 of PWD SR for Building 20Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -65 mm nominal dia Pipes-OHTRmtr608.16608.16650.0FalseNoneNoneFalseNoneFalse395304.00
3341836117407NoneI.No. 13.50.6, P.No.125 of PWD SR for Building 202Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -50 mm nominal dia Pipes-OHTRmtr432.32432.321000.0FalseNoneNoneFalseNoneFalse432320.00
3341837117407NoneI.No. 1.10, P.No.5 of PWD SR 2023-24 Vol- IRefilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications-OHTm179.2179.2862.5FalseNoneNoneFalseNoneFalse154560.00
3341838117407NoneI.No. 13.9.6, P.No.151 of SR 20223-24 Vol-IV WaterProviding, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 5.00 HP/3.7KW: 30 STG-OHTEach31259.231259.21.0FalseNoneNoneFalseNoneFalse31259.20
3341839117407NoneI.No. 13.23.2, P.No.151 of SR 20223-24 Vol-IV WateSupply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. : Size 80 mmEach668.64668.642.0FalseNoneNoneFalseNoneFalse1337.280
3341840117407NoneI.No. 13.22.2, P.No.154 of SR 20223-24 Vol-IV Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments : 1x3x2.5 Sqm-OHTEach95.295.220.0FalseNoneNoneFalseNoneFalse1904.00
3341841117407NoneI.No. 13.22.2, P.No.154 of SR 20223-24 Vol-IV Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments : size 65 mm-OHTEach1624.01624.010.0FalseNoneNoneFalseNoneFalse16240.00
3341842117407NoneI.No. 13.22.2, P.No.154 of SR 20223-24 Vol-IVSupply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments : size 65 mm-OHTEach1736.01736.03.0FalseNoneNoneFalseNoneFalse5208.00
3341843117407NoneI.No. 13.23.2, P.No.154 of SR 20223-24 Vol-IVSupply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumps-OHTEach10696.010696.01.0FalseNoneNoneFalseNoneFalse10696.00
3341844117407NoneI.No. 13.30, P.No.154 of SR 20223-24 Vol-IVSupply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark-OHTSet5040.05040.01.0FalseNoneNoneFalseNoneFalse5040.00
3341845117407NoneI.No. 13.32, P.No.155 of SR 20223-24 Vol-IVLabour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply anderection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.-OHTJob7280.07280.01.0FalseNoneNoneFalseNoneFalse7280.00
3341846117407NoneI.No. 13.33, P.No.155 of SR 20223-24 Vol-IVLabour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.-OHTJob1512.01512.01.0FalseNoneNoneFalseNoneFalse1512.00
3341847117407NoneI.No. 13.39, P.No.157 of SR 20223-24 Vol-IV Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.-OHTJob4200.04200.01.0FalseNoneNoneFalseNoneFalse4200.00
3341848117407NoneI.No. 13.4.5, P.No.117 of PWD SR for Building 2023Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : -65 mm nominal bore-OHTCum1580.321580.3210.0FalseNoneNoneFalseNoneFalse15803.20
3341849117407NoneI.No. 13.39, P.No.157 of SR 20223-24 Vol-IVEarthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.-OHTJob4200.04200.01.0FalseNoneNoneFalseNoneFalse4200.00
3341850117407NoneI.No. 8.1, P.No.43 of PWD SR for Building 2023-24 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-OHTSqm236.32236.32325.0FalseNoneNoneFalseNoneFalse76804.00
3341851117407NoneI.No. 1.14.1, P.No.8 of PWD SR 2023-24 Vol- IEarth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 m-Sump Tank Cum119.95119.95441.75FalseNoneNoneFalseNoneFalse52987.91250
3341852117407NoneI.No. 1.23, P.No.11 of PWD SR 2023-24 Vol- IProviding and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.-Sump Tank Cum3003.843003.8426.98FalseNoneNoneFalseNoneFalse81043.60320
3341853117407NoneI.No. 2.3.3, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work-For Foundation Works-Sump Tank Cum8063.388063.3840.06FalseNoneNoneFalseNoneFalse323019.00280
3341854117407NoneI.No. 2.3.3, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including Form work- For side wall Cum8137.368137.3632.34FalseNoneNoneFalseNoneFalse263162.22240
3341855117407NoneI.No. 1.23, P.No.11 of PWD SR 2023-24 Vol- IProviding and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -Including FOrm work- For Sump Tank BeamCum11836.1611836.161.82FalseNoneNoneFalseNoneFalse21541.81120
3341856117407NoneI.No. 2.3.3, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Including form worn- For Sump tank Top SlabCum11096.411096.418.24FalseNoneNoneFalseNoneFalse202398.3360
3341857117407NoneI.No. 2.11.a., P.No.18 of PWD SR 2023-24 Vol- ISteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -Buildings-Sump tank MT84492.3284492.3210.28FalseNoneNoneFalseNoneFalse868581.04960
3341858117407NoneI.No. 15.6, P.No.150 of PWD SR for Building 2023Food Graded Water Proofing Membrane :-Providing and laying water proofing treatment to the Water tanks & Liq- uid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.-Sump tank Sqm567.84567.84188.5FalseNoneNoneFalseNoneFalse107037.840
3341859117407NoneI.No. 1.14.1, P.No.8 of PWD SR 2023-24 Vol- IFooting-Sump tank Cum114.24114.2474.81FalseNoneNoneFalseNoneFalse8546.29440
3341860117407NoneI.No. 2.1.2, P.No.15 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates-Sump tank Cum6343.686343.682.99FalseNoneNoneFalseNoneFalse18967.60320
3341861117407NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)-Pump House Cum7155.687155.6832.71FalseNoneNoneFalseNoneFalse234062.29280
3341862117407NoneI.No. 2.2.1, P.No.15 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -m20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Pump House Cum7041.447041.441.28FalseNoneNoneFalseNoneFalse9013.04320
3341863117407NoneI.No. 5.7, P.No.9 of PWD SR for 2023-24 Vol- IIProviding and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.-Pump House Cum7565.67565.614.95FalseNoneNoneFalseNoneFalse113105.720
3341864117407NoneI.No. 2.5.2, P.No.16 of PWD SR 2023-24 Vol- IProviding and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Pump House Cum7664.167664.1610.96FalseNoneNoneFalseNoneFalse83999.19360
3341865117407NoneI.No. 2.5.2, P.No.16 of PWD SR 2023-24 Vol- IAddition for Form work- Lintel-Pump House Cum4598.54598.51.51FalseNoneNoneFalseNoneFalse6943.7350
3341866117407NoneI.No. 2.5.2, P.No.16 of PWD SR 2023-24 Vol- IAddition for Form work- Chajja-Pump House Cum3448.873448.871.49FalseNoneNoneFalseNoneFalse5138.81630
3341867117407NoneI.No. 2.5.2, P.No.16 of PWD SR 2023-24 Vol- IAddition for Form work- Slab-Pump House Cum3832.083832.087.96FalseNoneNoneFalseNoneFalse30503.35680
3341868117407NoneI.No. 2.11.a., P.No.18 of PWD SR 2023-24 Vol- ISteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -Buildings-Pump House MT100191.84100191.840.88FalseNoneNoneFalseNoneFalse88168.81920
3341869117407NoneI.No. 8.7, P.No.42 of PWD SR for Building 2023-24 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-Pump House Sqm409.92409.9286.29FalseNoneNoneFalseNoneFalse35371.99680
3341870117407NoneI.No. 8.9, P.No.42 of PWD SR for Building 2023-24 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-Pump House Sqm431.2431.270.29FalseNoneNoneFalseNoneFalse30309.0480
3341871117407NoneI.No. 11.34B, P.No.86 of PWD SR for Building 2023-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Pump House Kg204.96204.96171.0FalseNoneNoneFalseNoneFalse35048.160
3341872117407NoneI.No. 8.25, P.No.45 of PWD SR for Building 2023-24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Pump House Kg153.44153.44138.19FalseNoneNoneFalseNoneFalse21203.87360
3341873117407NoneI.No. 8.28, P.No.45 of PWD SR for Building 2023-24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-Pump House Sqm99.6899.68172.72FalseNoneNoneFalseNoneFalse17216.72960
3341874117407NoneI.No. 12.12, P.No.99 of PWD SR for Building 2023-2Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Pump House Cum14904.2414904.240.26FalseNoneNoneFalseNoneFalse3875.10240
3341875117407NoneI.No. 12.51, P.No.104 of PWD SR for Building 2023-Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Pump House Nos1137.921137.922.0FalseNoneNoneFalseNoneFalse2275.840
3341876117407NoneI.No. 12.18, P.No.100 of PWD SR for Building 2023-Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )-PUMP HOUSESqm7365.127365.124.41FalseNoneNoneFalseNoneFalse32480.17920
3341877117407NoneI.No. 22.15.4, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Aldrop 16mm dia, 300mm -PUMP HOUSESqm420.0420.04.0FalseNoneNoneFalseNoneFalse1680.00
3341878117407NoneI.No. 22.15.8, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS hinges 125 mm-PUMP HOUSESqm56.056.012.0FalseNoneNoneFalseNoneFalse672.00
3341879117407NoneI.No. 22.15.10, P.No.219 of PWD SR for Building 20Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Door stopper 75mm-PUMP HOUSENos112.0112.02.0FalseNoneNoneFalseNoneFalse224.00
3341880117407NoneI.No. 22.15.5, P.No.219 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Tower Bolts 150x10mm-PUMP HOUSENos134.4134.48.0FalseNoneNoneFalseNoneFalse1075.20
3341881117407NoneI.No. 22.15.1, P.No.218 of PWD SR for Building 202Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge -SS Handles 200mm-PUMP HOUSENos504.0504.04.0FalseNoneNoneFalseNoneFalse2016.00
3341882117407NoneI.No. 12.86, P.No.109 of PWD SR for Building 2023-Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.-PUMP HOUSESqm6036.86036.89.0FalseNoneNoneFalseNoneFalse54331.20
3341883117407NoneI.No. 8.33.3, P.No.47 of PWD SR for Building 2023-Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PUMP HOUSESqm155.68155.689.0FalseNoneNoneFalseNoneFalse1401.120
3341884117407NoneI.No. 8.33.2, P.No.46 of PWD SR for Building 2023-Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PUMP HOUSESqm154.56154.568.82FalseNoneNoneFalseNoneFalse1363.21920
3341885117407NoneI.No. 9.2, P.No.59 of PWD SR for Building 2023-24 Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 ce- ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge.-PUMP HOUSESqm896.0896.029.26FalseNoneNoneFalseNoneFalse26216.960
17192950820001NoneNoneOther Works20 SEA WATER SUPPLY AND DISTRIBUTION WITH GROUND WATER2124589.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341886117408NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum119.95119.95270.75FalseNoneNoneFalseNoneFalse32476.46250
3341887117408NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.8413.78FalseNoneNoneFalseNoneFalse41392.91520
3341888117408NoneI.No. 2.3.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7767.487767.4824.41FalseNoneNoneFalseNoneFalse189604.18680
3341889117408NoneI.No. 2.3.3, P.No.16 of PWD Common SR 2023-24 Vol-Addition for Form work- Open foundationCum295.9295.924.41FalseNoneNoneFalseNoneFalse7222.9190
3341890117408NoneI.No. 2.3.3, P.No.16 of PWD Common SR 2023-24 Vol-Basement level worksCum7397.67397.638.45FalseNoneNoneFalseNoneFalse284437.720
3341891117408NoneI.No. 2.3.3, P.No.16 of PWD Common SR 2023-24 Vol-Addition for Form work- Side wallCum739.76739.7638.45FalseNoneNoneFalseNoneFalse28443.7720
3341892117408NoneI.No. 2.3.3, P.No.16 of PWD Common SR 2023-24 Vol-Addition for Form work- BeamsCum4438.564438.561.82FalseNoneNoneFalseNoneFalse8078.17920
3341893117408NoneI.No. 2.3.3, P.No.16 of PWD Common SR 2023-24 Vol-Addition for Form work- Top SlabCum3698.83698.811.55FalseNoneNoneFalseNoneFalse42721.140
3341894117408NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.847.02FalseNoneNoneFalseNoneFalse703346.71680
3341895117408NoneI.No. 15.6, P.No.150 of PWD SR for Building 2023-2Food Graded Water Proofing Membrane :-Providing and laying water proofing treatment to the Water tanks & Liq- uid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.Sqm567.84567.84124.6FalseNoneNoneFalseNoneFalse70752.8640
3341896117408NoneI.No. 13.40.4, P.No.157 of SR 20223-24 Vol-IV WateSupply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. : 5 HP, size 80x65 Head 23.50M, Discharge 600 LPMEach24987.224987.21.0FalseNoneNoneFalseNoneFalse24987.20
3341897117408NoneI.No. 13.43.1, P.No.157 of SR 20223-24 Vol-IV WateSupply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. Upto 7.5 HP centrifugal pumpEach10640.010640.01.0FalseNoneNoneFalseNoneFalse10640.00
3341898117408NoneI.No. 13.44, P.No.158 of SR 20223-24 Vol-IV Water Supply, delivery, erection and commissioning at site lighting distribution board suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments.Each3920.03920.01.0FalseNoneNoneFalseNoneFalse3920.00
3341899117408NoneI.No. 13.46, P.No.158 of SR 20223-24 Vol-IV Water Providing and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets with ISI mark and its latest amendments.Each629.44629.4410.0FalseNoneNoneFalseNoneFalse6294.40
3341900117408NoneI.No. 13.48, P.No.158 of SR 20223-24 Vol-IV Water Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump above 12.50HP confirming with ISI mark and its latest amendments.Each2464.02464.010.0FalseNoneNoneFalseNoneFalse24640.00
3341901117408NoneI.No. 13.39, P.No.157 of SR 20223-24 Vol-IV Water Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job4200.04200.01.0FalseNoneNoneFalseNoneFalse4200.00
3341902117408NoneI.No. 13.9.6, P.No.151 of SR 20223-24 Vol-IV WaterProviding, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 5.00 HP/3.7KW: 30 STGEach31259.231259.21.0FalseNoneNoneFalseNoneFalse31259.20
3341903117408NoneI.No. 13.23.2, P.No.151 of SR 20223-24 Vol-IV WateSupply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. : Size 80 mmEach668.64668.642.0FalseNoneNoneFalseNoneFalse1337.280
3341904117408NoneI.No. 13.22.2, P.No.154 of SR 20223-24 Vol-IV WateSupply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments : 1x3x2.5 SqmEach95.295.220.0FalseNoneNoneFalseNoneFalse1904.00
3341905117408NoneI.No. 13.22.2, P.No.154 of SR 20223-24 Vol-IV WateSupply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments : size 65 mmEach1624.01624.010.0FalseNoneNoneFalseNoneFalse16240.00
3341906117408NoneI.No. 13.22.2, P.No.154 of SR 20223-24 Vol-IV WateSupply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments : size 65 mmEach1736.01736.03.0FalseNoneNoneFalseNoneFalse5208.00
3341907117408NoneI.No. 13.23.2, P.No.154 of SR 20223-24 Vol-IV WateSupply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 3 to 6 HP pumpsEach10696.010696.01.0FalseNoneNoneFalseNoneFalse10696.00
3341908117408NoneI.No. 13.30, P.No.154 of SR 20223-24 Vol-IV Water Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI markSet5040.05040.01.0FalseNoneNoneFalseNoneFalse5040.00
3341909117408NoneI.No. 13.32, P.No.155 of SR 20223-24 Vol-IV Water Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply anderection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job7280.07280.01.0FalseNoneNoneFalseNoneFalse7280.00
3341910117408NoneI.No. 13.33, P.No.155 of SR 20223-24 Vol-IV Water Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer inchargJob1512.01512.01.0FalseNoneNoneFalseNoneFalse1512.00
3341911117408NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.246.4FalseNoneNoneFalseNoneFalse731.1360
3341912117408NoneI.No. 2.1.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.681.02FalseNoneNoneFalseNoneFalse6841.83360
3341913117408NoneI.No. 5.4, P.No.9 of PWD SR for Building 2023-24 VProviding Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.687.78FalseNoneNoneFalseNoneFalse55671.19040
3341914117408NoneI.No. 2.2.3, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7096.327096.320.77FalseNoneNoneFalseNoneFalse5464.16640
3341915117408NoneI.No. 13.33, P.No.155 of SR 20223-24 Vol-IV Water RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete.m1512.01512.02.0FalseNoneNoneFalseNoneFalse3024.00
3341916117408NoneI.No. 13.33, P.No.155 of SR 20223-24 Vol-IV Water Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0: HDPE Grade PE80-PN10.0,75mm diam369.6369.640.0FalseNoneNoneFalseNoneFalse14784.00
3341917117408NoneI.No. 7.3, P.No.85 of SR 20223-24 Vol-IV Water supProviding and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved pint etc. complete including all lead and lifts etc.Each2396.82396.82.0FalseNoneNoneFalseNoneFalse4793.60
3341918117408NoneI.No. 13.50.7, P.No.125 of PWD SR for Building 202Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work -65 mm nominal dia Pipesm608.16608.16460.0FalseNoneNoneFalseNoneFalse279753.60
3341919117408NoneI.No. 11.59, P.No.95 of PWD SR for Building 2023-2Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer- in-charge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade)m941.92941.92201.6FalseNoneNoneFalseNoneFalse189891.0720
17192950820001NoneNoneOther Works21 RCC BOX CULVERT2197290.54
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341920117409NoneS.R.I.No. 13.8, P.121 of SR for Roads and BridgesPCC M15 Grade leveling course below approach slab complete as per drawing and Technical specificationCum7628.327628.3227.75FalseNoneNoneFalseNoneFalse211685.880
3341921117409NoneS.R.I.No. 13.9, P.122 of SR for Roads and BridgesReinforced cement concrete M30 grade for approach slab including reinforcement and formwork complete as per drawing and Technical specification (Batching Plant)Cum13255.213255.235.0FalseNoneNoneFalseNoneFalse463932.00
3341922117409NoneS.R.I.No. 13.4, P.121 of SR for Roads and BridgesConstruction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, c/c spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.m2608.482608.4858.0FalseNoneNoneFalseNoneFalse151291.840
3341923117409NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7551.047551.0417.28FalseNoneNoneFalseNoneFalse130481.97120
3341924117409NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Addition for Form workCum755.1755.117.28FalseNoneNoneFalseNoneFalse13048.1280
3341925117409NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.24225.0FalseNoneNoneFalseNoneFalse25704.00
3341926117409NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.92540.0FalseNoneNoneFalseNoneFalse160876.80
3341927117409NoneI.No. 1.23, P.No.11 of PWD Common SR 2023-24 Vol- Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.8429.66FalseNoneNoneFalseNoneFalse89093.89440
3341928117409NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7928.597928.5944.9FalseNoneNoneFalseNoneFalse355993.6910
3341929117409NoneI.No. 2.4.4, P.No.16 of PWD Common SR 2023-24 Vol-Addition for Form workCum755.1755.124.9FalseNoneNoneFalseNoneFalse18801.990
3341930117409NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.844.23FalseNoneNoneFalseNoneFalse423811.48320
3341931117409NoneS.R.I.No. 12.2, P.117, of PWD SR for Roads and BrProviding weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with PVC Pipe 110mm outer dia at 2 kg per m2, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical SpecificationsNos267.68267.6815.0FalseNoneNoneFalseNoneFalse4015.20
3341932117409NoneS.R.I.No.14.4, P.103, Vol-3 PWD SR 2021-22 continuProviding and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500- 29, prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 9.5 mm nominal size at the rate of 0.005 m3 per 10 m2 and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces not less than 100 deg. C, protruding 1 mm to 4 mm over mastic surface, all complete as per clause 515.Nos472.64472.64255.0FalseNoneNoneFalseNoneFalse120523.20
3341933117409NoneI.No. 1.8, P.No.7 of PWD Common SR 2023-24 Vol- IConstruction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum530.88530.8852.8FalseNoneNoneFalseNoneFalse28030.4640
17192950820000NoneNoneOther Works23 GREENARIES AND LANDSCAPING ON THE SOUTH SIDE AND ON BENGRE SIDE1498646.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341934117410NoneI.No. 1.14.1, P.No.8 of PWD Common SR 2023-24 Vol-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 mCum114.24114.2410.01FalseNoneNoneFalseNoneFalse1143.54240
3341935117410NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6343.686343.682.36FalseNoneNoneFalseNoneFalse14971.08480
3341936117410NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7096.327096.3210.28FalseNoneNoneFalseNoneFalse72950.16960
3341937117410NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Coping Concrete Centre Col footing Centre Col footing Cum7096.327096.323.1FalseNoneNoneFalseNoneFalse21998.5920
3341938117410NoneI.No. 2.1.2, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel worksAddition for Form work- Earth retaining srtuctuCum709.63709.6310.28FalseNoneNoneFalseNoneFalse7294.99640
3341939117410NoneI.No. 2.4.3, P.No.16 of PWD Common SR 2023-24 Vol-Addition for Form work- Minor ProjectionCum4967.424967.423.1FalseNoneNoneFalseNoneFalse15399.0020
3341940117410NoneI.No. 2.11.a., P.No.18 of PWD Common SR 2023-24 VoSteel Fabrication -Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. -BuildingsMT100191.84100191.841.07FalseNoneNoneFalseNoneFalse107205.26880
3341941117410NoneI.No. 1.9, P.No.7 of PWD Common SR 2023-24 Vol- IFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.9223.57FalseNoneNoneFalseNoneFalse7021.97440
3341942117410NoneI.No. 9.32, P.No.64 of PWD SR for Building 2023-24Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Sqm2891.842891.8410.56FalseNoneNoneFalseNoneFalse30537.83040
3341943117410NoneI.No. 10.2, P.No.69 of PWD SR for Building 2023-24Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.m367.36367.3617.6FalseNoneNoneFalseNoneFalse6465.5360
3341944117410NoneI.No. 10.21, P.No.72 of PWD SR for Building 2023-2Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Sqm2439.362439.3614.08FalseNoneNoneFalseNoneFalse34346.18880
3341945117410NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6963.046963.040.43FalseNoneNoneFalseNoneFalse2994.10720
3341946117410NoneI.No. 8.42.3, P.No.74 ofSR 20223-24 Vol-III Roads Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stonem518.56518.5621.7FalseNoneNoneFalseNoneFalse11252.7520
3341947117410NoneS.R.I.No. 12.10. G(a), P.49, Vol-7 PWD SR 2021-2Lawn Development: Procurement of quality lawn grassTurfSqm112.0112.041.1FalseNoneNoneFalseNoneFalse4603.20
3341948117410NoneI.No. 2.1.4, P.No.15 of PWD Common SR 2023-24 Vol-Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6963.046963.0433.48FalseNoneNoneFalseNoneFalse233122.57920
3341949117410NoneI.No. 8.42.3, P.No.74 ofSR 20223-24 Vol-III Roads Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stonem518.56518.56810.0FalseNoneNoneFalseNoneFalse420033.60
3341950117410NoneI.No. 9.40, P.No.65 of PWD SR for Building 2023-24Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.Sqm1043.841043.84486.0FalseNoneNoneFalseNoneFalse507306.240
17192950820000NoneNoneOther Works06E ELE WORKS OF FISH LANDING AND AUCTION HALL1905786.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341951117411Nonecode01Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm73.9273.92800.0FalseNoneNoneFalseNoneFalse59136.00
3341952117411Nonecode02Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm87.3687.361100.0FalseNoneNoneFalseNoneFalse96096.00
3341953117411Nonecode03Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32 mm dia 2.5 mm thickm115.36115.36140.0FalseNoneNoneFalseNoneFalse16150.40
3341954117411Nonecode04Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm76.1676.16800.0FalseNoneNoneFalseNoneFalse60928.00
3341955117411Nonecode05Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm88.4888.48900.0FalseNoneNoneFalseNoneFalse79632.00
3341956117411Nonecode06Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32mm dia 2.5mm thickm110.88110.88120.0FalseNoneNoneFalseNoneFalse13305.60
3341957117411Nonecode07Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20 mm deep Junction boxEach54.8854.88120.0FalseNoneNoneFalseNoneFalse6585.60
3341958117411Nonecode08Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mm deep Junction boxEach62.7262.72130.0FalseNoneNoneFalseNoneFalse8153.60
3341959117411Nonecode09Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )No131.04131.0459.0FalseNoneNoneFalseNoneFalse7731.360
3341960117411Nonecode10Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Way TP & NEach4522.564522.568.0FalseNoneNoneFalseNoneFalse36180.480
3341961117411Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2WayEach154.56154.5630.0FalseNoneNoneFalseNoneFalse4636.80
3341962117411Nonecode12Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4-5WayEach198.24198.2420.0FalseNoneNoneFalseNoneFalse3964.80
3341963117411Nonecode13Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8WayEach292.32292.3225.0FalseNoneNoneFalseNoneFalse7308.00
3341964117411Nonecode14Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12WayEach357.28357.2850.0FalseNoneNoneFalseNoneFalse17864.00
3341965117411Nonecode15Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 ModuleEach153.44153.4430.0FalseNoneNoneFalseNoneFalse4603.20
3341966117411Nonecode16Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4 ModuleEach196.0196.020.0FalseNoneNoneFalseNoneFalse3920.00
3341967117411Nonecode17Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8 ModuleEach318.08318.0825.0FalseNoneNoneFalseNoneFalse7952.00
3341968117411Nonecode18Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 ModuleEach385.28385.2850.0FalseNoneNoneFalseNoneFalse19264.00
3341969117411Nonecode19Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch boxPoint301.28301.28100.0FalseNoneNoneFalseNoneFalse30128.00
3341970117411Nonecode20Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxPoint424.48424.48110.0FalseNoneNoneFalseNoneFalse46692.80
3341971117411Nonecode21Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxPoint621.6621.6101.0FalseNoneNoneFalseNoneFalse62781.60
3341972117411Nonecode22Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps one way SwitchEach114.24114.24511.0FalseNoneNoneFalseNoneFalse58376.640
3341973117411Nonecode23Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps 3way socketEach191.52191.52200.0FalseNoneNoneFalseNoneFalse38304.00
3341974117411Nonecode24Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Stepped Fan Regulator Two ModuleEach399.84399.8459.0FalseNoneNoneFalseNoneFalse23590.560
3341975117411Nonecode25Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32Amps DP switchEach365.12365.1230.0FalseNoneNoneFalseNoneFalse10953.60
3341976117411Nonecode26Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6/16Amps universal socketEach264.32264.3230.0FalseNoneNoneFalseNoneFalse7929.60
3341977117411Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.121800.0FalseNoneNoneFalseNoneFalse52416.00
3341978117411Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.042450.0FalseNoneNoneFalseNoneFalse115248.00
3341979117411Nonecode29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.562100.0FalseNoneNoneFalseNoneFalse148176.00
3341980117411Nonecode30Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmmm103.03103.03360.0FalseNoneNoneFalseNoneFalse37090.80
3341981117411Nonecode31Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100 AEach9558.089558.081.0FalseNoneNoneFalseNoneFalse9558.080
3341982117411Nonecode32Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100A to 250A TPDT/COSEach500.64500.641.0FalseNoneNoneFalseNoneFalse500.640
3341983117411Nonecode33Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-FOUR Pole,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100Amps 25kA.Each9505.449505.441.0FalseNoneNoneFalseNoneFalse9505.440
3341984117411Nonecode34Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.6860.0FalseNoneNoneFalseNoneFalse49660.80
3341985117411Nonecode35Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.2720.0FalseNoneNoneFalseNoneFalse68185.40
3341986117411Nonecode36Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each10432.810432.81.0FalseNoneNoneFalseNoneFalse10432.80
3341987117411Nonecode37Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.83.0FalseNoneNoneFalseNoneFalse1730.40
3341988117411Nonecode38Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.4880000.0FalseNoneNoneFalseNoneFalse38400.00
3341989117411Nonecode39Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.88.0FalseNoneNoneFalseNoneFalse22086.40
3341990117411Nonecode40Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.410.0FalseNoneNoneFalseNoneFalse4424.00
3341991117411Nonecode41Supplying of PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70pc lumen maintenance with CRI over 80. Power Input: 220-240V@ 50/60Hz & Power factor over 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4ft - 20/22 wEach772.8772.8174.0FalseNoneNoneFalseNoneFalse134467.20
3341992117411Nonecode42Supply of round/square recess/surface mounted rolling type LED Down light GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI over 80. Power Input: 220-240V @50/60Hz & Power factor over 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach991.2991.238.0FalseNoneNoneFalseNoneFalse37665.60
3341993117411Nonecode43Supplying & fixing of retrofit type - LED bulb with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should be less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9 W , 6500 KEach172.48172.486.0FalseNoneNoneFalseNoneFalse1034.880
3341994117411Nonecode44Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT over 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire over IK08. Power Factor over 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED Streetlight 70W,Each6711.046711.045.0FalseNoneNoneFalseNoneFalse33555.20
3341995117411Nonecode45Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete...( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each1671.041671.0429.0FalseNoneNoneFalseNoneFalse48460.160
3341996117411Nonecode46Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )48" Sweep 5 Star (1200mm)Each2998.242998.2459.0FalseNoneNoneFalseNoneFalse176896.160
3341997117411Nonecode47Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Using 32mm dia G.I.PipeEach1450.41450.45.0FalseNoneNoneFalseNoneFalse7252.00
3341998117411Nonecode48Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )On wall / ceiling / Rafter / GirdersEach136.64136.64212.0FalseNoneNoneFalseNoneFalse28967.680
3341999117411Nonecode49Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each352.8352.859.0FalseNoneNoneFalseNoneFalse20815.20
3342000117411Nonecode50Extra length of GI pipe of class B 19mm dia for down rod.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ).( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each220.64220.6459.0FalseNoneNoneFalseNoneFalse13017.760
3342001117411Nonecode51Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each551.04551.0429.0FalseNoneNoneFalseNoneFalse15980.160
3342002117411Nonecode52Grounding of Towers/Equipments -Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges -Maerial cost Rs.Set5850.885850.884.0FalseNoneNoneFalseNoneFalse23403.520
3342003117411Nonecode53Grounding of Towers/Equipments - Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges -Labour charges Rs,Km2364.322364.324.0FalseNoneNoneFalseNoneFalse9457.280
3342004117411Nonecode54Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractorm375.2375.240.0FalseNoneNoneFalseNoneFalse15008.00
3342005117411Nonecode55Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-397570 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) -Materials cost Rs.Km356061.44356061.440.1FalseNoneNoneFalseNoneFalse35606.1440
3342006117411Nonecode56Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff -LT Cable -35 to 95 SqmmKm34875.6834875.680.1FalseNoneNoneFalseNoneFalse3487.5680
3342007117411Nonecode57Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo44.844.82.0FalseNoneNoneFalseNoneFalse89.60
3342008117411Nonecode58Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 GmNo99.6899.686.0FalseNoneNoneFalseNoneFalse598.080
3342009117411Nonecode59Brass Cable Gland 45 mmNo220.64220.642.0FalseNoneNoneFalseNoneFalse441.280
17192950820001NoneNoneOther Works08E Ele Works of NET MENDING SHEDS - 03 No.685922.45
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3342010117412Nonecode01Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm73.9273.92240.0FalseNoneNoneFalseNoneFalse17740.80
3342011117412Nonecode02Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm87.3687.36300.0FalseNoneNoneFalseNoneFalse26208.00
3342012117412Nonecode03Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32 mm dia 2.5 mm thickm115.36115.3660.0FalseNoneNoneFalseNoneFalse6921.60
3342013117412Nonecode04Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm76.1676.1690.0FalseNoneNoneFalseNoneFalse6854.40
3342014117412Nonecode05Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm88.4888.48150.0FalseNoneNoneFalseNoneFalse13272.00
3342015117412Nonecode06Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32mm dia 2.5mm thickm110.88110.88210.0FalseNoneNoneFalseNoneFalse23284.80
3342016117412Nonecode07Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20 mm deep Junction boxEach54.8854.8830.0FalseNoneNoneFalseNoneFalse1646.40
3342017117412Nonecode08Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mm deep Junction boxEach62.7262.7245.0FalseNoneNoneFalseNoneFalse2822.40
3342018117412Nonecode09Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )No131.04131.0424.0FalseNoneNoneFalseNoneFalse3144.960
3342019117412Nonecode10Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Way TP & NEach4522.564522.563.0FalseNoneNoneFalseNoneFalse13567.680
3342020117412Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2WayEach154.56154.5618.0FalseNoneNoneFalseNoneFalse2782.080
3342021117412Nonecode12Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4-5WayEach198.24198.2418.0FalseNoneNoneFalseNoneFalse3568.320
3342022117412Nonecode13Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12WayEach357.28357.2824.0FalseNoneNoneFalseNoneFalse8574.720
3342023117412Nonecode14Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 ModuleEach153.44153.4418.0FalseNoneNoneFalseNoneFalse2761.920
3342024117412Nonecode15Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4 ModuleEach196.0196.018.0FalseNoneNoneFalseNoneFalse3528.00
3342025117412Nonecode16Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 ModuleEach385.28385.2824.0FalseNoneNoneFalseNoneFalse9246.720
3342026117412Nonecode17Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch boxPoint301.28301.2824.0FalseNoneNoneFalseNoneFalse7230.720
3342027117412Nonecode18Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxPoint424.48424.4824.0FalseNoneNoneFalseNoneFalse10187.520
3342028117412Nonecode19Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxPoint621.6621.624.0FalseNoneNoneFalseNoneFalse14918.40
3342029117412Nonecode20Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps one way SwitchEach114.24114.24102.0FalseNoneNoneFalseNoneFalse11652.480
3342030117412Nonecode21Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps 3way socketEach191.52191.5230.0FalseNoneNoneFalseNoneFalse5745.60
3342031117412Nonecode22Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Stepped Fan Regulator Two ModuleEach399.84399.8424.0FalseNoneNoneFalseNoneFalse9596.160
3342032117412Nonecode23Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32Amps DP switchEach365.12365.1212.0FalseNoneNoneFalseNoneFalse4381.440
3342033117412Nonecode24Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.12360.0FalseNoneNoneFalseNoneFalse10483.20
3342034117412Nonecode25Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.04390.0FalseNoneNoneFalseNoneFalse18345.60
3342035117412Nonecode26Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.56225.0FalseNoneNoneFalseNoneFalse15876.00
3342036117412Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmmm103.03103.0390.0FalseNoneNoneFalseNoneFalse9272.70
3342037117412Nonecode28Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 63 AEach7706.727706.723.0FalseNoneNoneFalseNoneFalse23120.160
3342038117412Nonecode29Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 15A to 63A TPDT/COSEach324.8324.83.0FalseNoneNoneFalseNoneFalse974.40
3342039117412Nonecode30Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-FOUR Pole,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100Amps 25kA.Each9505.449505.443.0FalseNoneNoneFalseNoneFalse28516.320
3342040117412Nonecode31Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.6818.0FalseNoneNoneFalseNoneFalse14898.240
3342041117412Nonecode32Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.2712.0FalseNoneNoneFalseNoneFalse40911.240
3342042117412Nonecode33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each10432.810432.83.0FalseNoneNoneFalseNoneFalse31298.40
3342043117412Nonecode34Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.89.0FalseNoneNoneFalseNoneFalse5191.20
3342044117412Nonecode35Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.4860000.0FalseNoneNoneFalseNoneFalse28800.00
3342045117412Nonecode36Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.81.5FalseNoneNoneFalseNoneFalse4141.20
3342046117412Nonecode37Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.412.0FalseNoneNoneFalseNoneFalse5308.80
3342047117412Nonecode38Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED light fighting 1 x4'- 20/22 wEach772.8772.836.0FalseNoneNoneFalseNoneFalse27820.80
3342048117412Nonecode39Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 70W,Each6711.046711.043.0FalseNoneNoneFalseNoneFalse20133.120
3342049117412Nonecode40Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Using 32mm dia G.I.PipeEach1450.41450.43.0FalseNoneNoneFalseNoneFalse4351.20
3342050117412Nonecode41Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )On wall / ceiling / Rafter / GirdersEach136.64136.6436.0FalseNoneNoneFalseNoneFalse4919.040
3342051117412Nonecode42Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each352.8352.824.0FalseNoneNoneFalseNoneFalse8467.20
3342052117412Nonecode43Extra length of GI pipe of class B 19mm dia for down rod.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ).( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each220.64220.6424.0FalseNoneNoneFalseNoneFalse5295.360
3342053117412Nonecode44Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges -Material cost Rs.Set5850.885850.889.0FalseNoneNoneFalseNoneFalse52657.920
3342054117412Nonecode45Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges -Labour charges Rs,Km2364.322364.329.0FalseNoneNoneFalseNoneFalse21278.880
3342055117412Nonecode46Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractorm375.2375.290.0FalseNoneNoneFalseNoneFalse33768.00
3342056117412Nonecode47Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975. 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Materials cost Rs.Km200449.76200449.760.24FalseNoneNoneFalseNoneFalse48107.94240
3342057117412Nonecode48Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable35 to 95 SqmmKm34875.6834875.680.24FalseNoneNoneFalseNoneFalse8370.16320
3342058117412Nonecode49Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.2412.0FalseNoneNoneFalseNoneFalse362.880
3342059117412Nonecode50Heavy Duty Copper Terminal Long Barrel 50 Sqmm Copper Terminal, Apprx Wt: 26 GmNo64.9664.9636.0FalseNoneNoneFalseNoneFalse2338.560
3342060117412Nonecode51Brass Cable Gland. 40 mmNo106.4106.412.0FalseNoneNoneFalseNoneFalse1276.80
17192950820000NoneNoneOther Works23E Electrical Works - Greenary155941.04
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3342061117413Nonecode01Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975, 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km132164.48132164.480.1FalseNoneNoneFalseNoneFalse13216.4480
3342062117413Nonecode02Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable -2.5 to 25 SqmmKm23392.3223392.320.1FalseNoneNoneFalseNoneFalse2339.2320
3342063117413Nonecode03Heavy Duty Copper Terminal Long Barrel -25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.248.0FalseNoneNoneFalseNoneFalse241.920
3342064117413Nonecode04Brass Cable Gland. 25 mmNo88.4888.482.0FalseNoneNoneFalseNoneFalse176.960
3342065117413Nonecode05Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 150WNo13988.813988.87.0FalseNoneNoneFalseNoneFalse97921.60
3342066117413Nonecode06Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )No181.44181.447.0FalseNoneNoneFalseNoneFalse1270.080
3342067117413Nonecode07Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) -16SWGSq CM0.480.4850000.0FalseNoneNoneFalseNoneFalse24000.00
3342068117413Nonecode08Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.80.5FalseNoneNoneFalseNoneFalse1380.40
3342069117413Nonecode09Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.44.0FalseNoneNoneFalseNoneFalse1769.60
3342070117413Nonecode10Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. ..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4C x 4 mm2m252.0252.04.0FalseNoneNoneFalseNoneFalse1008.00
3342071117413Nonecode11Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.1230.0FalseNoneNoneFalseNoneFalse873.60
3342072117413Nonecode12Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.0430.0FalseNoneNoneFalseNoneFalse1411.20
3342073117413Nonecode13Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.5630.0FalseNoneNoneFalseNoneFalse2116.80
3342074117413Nonecode14Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges -Maerial cost Rs.Set5850.885850.881.0FalseNoneNoneFalseNoneFalse5850.880
3342075117413Nonecode15Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges -Labour charges Rs,Km2364.322364.321.0FalseNoneNoneFalseNoneFalse2364.320
17192950820001NoneNoneOther Works19E Electrical Works to OHT171409.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3342076117414Nonecode01Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm73.9273.9230.0FalseNoneNoneFalseNoneFalse2217.60
3342077117414Nonecode02Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm87.3687.3625.0FalseNoneNoneFalseNoneFalse2184.00
3342078117414Nonecode03Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm76.1676.1630.0FalseNoneNoneFalseNoneFalse2284.80
3342079117414Nonecode04Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm88.4888.4820.0FalseNoneNoneFalseNoneFalse1769.60
3342080117414Nonecode05Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20 mm deep Junction boxEach54.8854.885.0FalseNoneNoneFalseNoneFalse274.40
3342081117414Nonecode06Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mm deep Junction boxEach62.7262.725.0FalseNoneNoneFalseNoneFalse313.60
3342082117414Nonecode07Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )No131.04131.042.0FalseNoneNoneFalseNoneFalse262.080
3342083117414Nonecode08Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Way TP & NEach4522.564522.561.0FalseNoneNoneFalseNoneFalse4522.560
3342084117414Nonecode09Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2WayEach154.56154.562.0FalseNoneNoneFalseNoneFalse309.120
3342085117414Nonecode10Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4-5WayEach198.24198.242.0FalseNoneNoneFalseNoneFalse396.480
3342086117414Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12WayEach357.28357.282.0FalseNoneNoneFalseNoneFalse714.560
3342087117414Nonecode12Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 ModuleEach153.44153.442.0FalseNoneNoneFalseNoneFalse306.880
3342088117414Nonecode13Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4 ModuleEach196.0196.02.0FalseNoneNoneFalseNoneFalse392.00
3342089117414Nonecode14Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 ModuleEach385.28385.282.0FalseNoneNoneFalseNoneFalse770.560
3342090117414Nonecode15Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch boxPoint301.28301.288.0FalseNoneNoneFalseNoneFalse2410.240
3342091117414Nonecode16Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxPoint424.48424.488.0FalseNoneNoneFalseNoneFalse3395.840
3342092117414Nonecode17Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxPoint621.6621.68.0FalseNoneNoneFalseNoneFalse4972.80
3342093117414Nonecode18Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps one way SwitchEach114.24114.2410.0FalseNoneNoneFalseNoneFalse1142.40
3342094117414Nonecode19Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps 3way socketEach191.52191.522.0FalseNoneNoneFalseNoneFalse383.040
3342095117414Nonecode20Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Stepped Fan Regulator Two ModuleEach399.84399.842.0FalseNoneNoneFalseNoneFalse799.680
3342096117414Nonecode21Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32Amps DP switchEach365.12365.122.0FalseNoneNoneFalseNoneFalse730.240
3342097117414Nonecode22Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.1260.0FalseNoneNoneFalseNoneFalse1747.20
3342098117414Nonecode23Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.0460.0FalseNoneNoneFalseNoneFalse2822.40
3342099117414Nonecode24Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.5670.0FalseNoneNoneFalseNoneFalse4939.20
3342100117414Nonecode25Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmmm103.03103.0320.0FalseNoneNoneFalseNoneFalse2060.60
3342101117414Nonecode26Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 63 AEach7706.727706.721.0FalseNoneNoneFalseNoneFalse7706.720
3342102117414Nonecode27Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 15A to 63A TPDT/COSEach324.8324.81.0FalseNoneNoneFalseNoneFalse324.80
3342103117414Nonecode28Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-FOUR Pole,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100Amps 25kA.Each9505.449505.441.0FalseNoneNoneFalseNoneFalse9505.440
3342104117414Nonecode29Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.687.0FalseNoneNoneFalseNoneFalse5793.760
3342105117414Nonecode30Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.274.0FalseNoneNoneFalseNoneFalse13637.080
3342106117414Nonecode31Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each10432.810432.81.0FalseNoneNoneFalseNoneFalse10432.80
3342107117414Nonecode32Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.83.0FalseNoneNoneFalseNoneFalse1730.40
3342108117414Nonecode33Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.4840000.0FalseNoneNoneFalseNoneFalse19200.00
3342109117414Nonecode34Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.80.5FalseNoneNoneFalseNoneFalse1380.40
3342110117414Nonecode35Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.44.0FalseNoneNoneFalseNoneFalse1769.60
3342111117414Nonecode36Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED light fighting 1 x4'- 20/22 wEach772.8772.812.0FalseNoneNoneFalseNoneFalse9273.60
3342112117414Nonecode37Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED Streetlight 70W,Each6711.046711.041.0FalseNoneNoneFalseNoneFalse6711.040
3342113117414Nonecode38Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )48" Sweep 5 Star (1200mm)Each2998.242998.242.0FalseNoneNoneFalseNoneFalse5996.480
3342114117414Nonecode39Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Using 32mm dia G.I.PipeEach1450.41450.41.0FalseNoneNoneFalseNoneFalse1450.40
3342115117414Nonecode40Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )On wall / ceiling / Rafter / GirdersEach136.64136.6412.0FalseNoneNoneFalseNoneFalse1639.680
3342116117414Nonecode41Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each352.8352.82.0FalseNoneNoneFalseNoneFalse705.60
3342117117414Nonecode42Extra length of GI pipe of class B 19mm dia for down rod.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ).( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each220.64220.642.0FalseNoneNoneFalseNoneFalse441.280
3342118117414Nonecode43Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges Maerial cost Rs.Set5850.885850.882.0FalseNoneNoneFalseNoneFalse11701.760
3342119117414Nonecode44Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges Labour charges Rs,Km2364.322364.322.0FalseNoneNoneFalseNoneFalse4728.640
3342120117414Nonecode45Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractorm375.2375.25.0FalseNoneNoneFalseNoneFalse1876.00
3342121117414Nonecode46Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975 Materials cost Rs.Km132164.48132164.480.08FalseNoneNoneFalseNoneFalse10573.15840
3342122117414Nonecode47Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable -2.5 to 25 SqmmKm23392.3223392.320.08FalseNoneNoneFalseNoneFalse1871.38560
3342123117414Nonecode48Heavy Duty Copper Terminal Long Barrel, 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.2416.0FalseNoneNoneFalseNoneFalse483.840
3342124117414Nonecode49Brass Cable Gland. 25 mmNo88.4888.484.0FalseNoneNoneFalseNoneFalse353.920
17192950820000NoneNoneOther Works09E Electrical Works to Fishermen Rest Shed 03 nos1457951.94
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3342125117415Nonecode01Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm73.9273.92320.0FalseNoneNoneFalseNoneFalse23654.40
3342126117415Nonecode02Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm87.3687.36360.0FalseNoneNoneFalseNoneFalse31449.60
3342127117415Nonecode03Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32 mm dia 2.5 mm thickm115.36115.3680.0FalseNoneNoneFalseNoneFalse9228.80
3342128117415Nonecode04Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm76.1676.16160.0FalseNoneNoneFalseNoneFalse12185.60
3342129117415Nonecode05Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm88.4888.48360.0FalseNoneNoneFalseNoneFalse31852.80
3342130117415Nonecode06Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32mm dia 2.5mm thickm110.88110.8860.0FalseNoneNoneFalseNoneFalse6652.80
3342131117415Nonecode07Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20 mm deep Junction boxEach54.8854.8864.0FalseNoneNoneFalseNoneFalse3512.320
3342132117415Nonecode08Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mm deep Junction boxEach62.7262.7280.0FalseNoneNoneFalseNoneFalse5017.60
3342133117415Nonecode09Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )No131.04131.0432.0FalseNoneNoneFalseNoneFalse4193.280
3342134117415Nonecode10Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Way TP & NEach4522.564522.564.0FalseNoneNoneFalseNoneFalse18090.240
3342135117415Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2WayEach154.56154.5632.0FalseNoneNoneFalseNoneFalse4945.920
3342136117415Nonecode12Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4-5WayEach198.24198.2416.0FalseNoneNoneFalseNoneFalse3171.840
3342137117415Nonecode13Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8WayEach292.32292.3216.0FalseNoneNoneFalseNoneFalse4677.120
3342138117415Nonecode14Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12WayEach357.28357.2824.0FalseNoneNoneFalseNoneFalse8574.720
3342139117415Nonecode15Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 ModuleEach153.44153.4432.0FalseNoneNoneFalseNoneFalse4910.080
3342140117415Nonecode16Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4 ModuleEach196.0196.016.0FalseNoneNoneFalseNoneFalse3136.00
3342141117415Nonecode17Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8 ModuleEach318.08318.0816.0FalseNoneNoneFalseNoneFalse5089.280
3342142117415Nonecode18Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 ModuleEach385.28385.2824.0FalseNoneNoneFalseNoneFalse9246.720
3342143117415Nonecode19Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch boxPoint301.28301.2852.0FalseNoneNoneFalseNoneFalse15666.560
3342144117415Nonecode20Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxPoint424.48424.4856.0FalseNoneNoneFalseNoneFalse23770.880
3342145117415Nonecode21Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxPoint621.6621.660.0FalseNoneNoneFalseNoneFalse37296.00
3342146117415Nonecode22Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps one way SwitchEach114.24114.24260.0FalseNoneNoneFalseNoneFalse29702.40
3342147117415Nonecode23Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps 3way socketEach191.52191.5280.0FalseNoneNoneFalseNoneFalse15321.60
3342148117415Nonecode24Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Stepped Fan Regulator Two ModuleEach399.84399.8432.0FalseNoneNoneFalseNoneFalse12794.880
3342149117415Nonecode25Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32Amps DP switchEach365.12365.1224.0FalseNoneNoneFalseNoneFalse8762.880
3342150117415Nonecode26Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6/16Amps universal socketEach264.32264.3224.0FalseNoneNoneFalseNoneFalse6343.680
3342151117415Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.121400.0FalseNoneNoneFalseNoneFalse40768.00
3342152117415Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.042200.0FalseNoneNoneFalseNoneFalse103488.00
3342153117415Nonecode29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.561400.0FalseNoneNoneFalseNoneFalse98784.00
3342154117415Nonecode30Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmmm103.03103.03120.0FalseNoneNoneFalseNoneFalse12363.60
3342155117415Nonecode31Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100 AEach9558.089558.084.0FalseNoneNoneFalseNoneFalse38232.320
3342156117415Nonecode32Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100A to 250A TPDT/COSEach500.64500.644.0FalseNoneNoneFalseNoneFalse2002.560
3342157117415Nonecode33Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-FOUR Pole,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100Amps 25kA.Each9505.449505.444.0FalseNoneNoneFalseNoneFalse38021.760
3342158117415Nonecode34Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.6856.0FalseNoneNoneFalseNoneFalse46350.080
3342159117415Nonecode35Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.2720.0FalseNoneNoneFalseNoneFalse68185.40
3342160117415Nonecode36Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each10432.810432.84.0FalseNoneNoneFalseNoneFalse41731.20
3342161117415Nonecode37Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.812.0FalseNoneNoneFalseNoneFalse6921.60
3342162117415Nonecode38Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.48100000.0FalseNoneNoneFalseNoneFalse48000.00
3342163117415Nonecode39Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.82.0FalseNoneNoneFalseNoneFalse5521.60
3342164117415Nonecode40Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.416.0FalseNoneNoneFalseNoneFalse7078.40
3342165117415Nonecode41Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED light fighting 1 x4'- 20/22 wEach772.8772.880.0FalseNoneNoneFalseNoneFalse61824.00
3342166117415Nonecode42Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )9 W , 6500 KEach172.48172.4832.0FalseNoneNoneFalseNoneFalse5519.360
3342167117415Nonecode43Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED Streetlight 70W,Each6711.046711.048.0FalseNoneNoneFalseNoneFalse53688.320
3342168117415Nonecode44Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete...( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each1671.041671.048.0FalseNoneNoneFalseNoneFalse13368.320
3342169117415Nonecode45Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )48" Sweep 5 Star (1200mm)Each2998.242998.2424.0FalseNoneNoneFalseNoneFalse71957.760
3342170117415Nonecode46Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 LEach13360.4813360.488.0FalseNoneNoneFalseNoneFalse106883.840
3342171117415Nonecode47Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Using 32mm dia G.I.PipeEach1450.41450.416.0FalseNoneNoneFalseNoneFalse23206.40
3342172117415Nonecode48Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )On wall / ceiling / Rafter / GirdersEach136.64136.6480.0FalseNoneNoneFalseNoneFalse10931.20
3342173117415Nonecode49Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each352.8352.832.0FalseNoneNoneFalseNoneFalse11289.60
3342174117415Nonecode50Extra length of GI pipe of class B 19mm dia for down rod.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ).( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each220.64220.6432.0FalseNoneNoneFalseNoneFalse7060.480
3342175117415Nonecode51Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each551.04551.048.0FalseNoneNoneFalseNoneFalse4408.320
3342176117415Nonecode52Erection charges for fixing a ... litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top.upto 30 LitresEach743.68743.688.0FalseNoneNoneFalseNoneFalse5949.440
3342177117415Nonecode53Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges Maerial cost Rs.Set5850.885850.888.0FalseNoneNoneFalseNoneFalse46807.040
3342178117415Nonecode54Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges Labour charges Rs,Km2364.322364.3216.0FalseNoneNoneFalseNoneFalse37829.120
3342179117415Nonecode55Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractorm375.2375.2120.0FalseNoneNoneFalseNoneFalse45024.00
3342180117415Nonecode56Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975, 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km200449.76200449.760.2FalseNoneNoneFalseNoneFalse40089.9520
3342181117415Nonecode57Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm50569.7350569.730.2FalseNoneNoneFalseNoneFalse10113.9460
3342182117415Nonecode58Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.2416.0FalseNoneNoneFalseNoneFalse483.840
3342183117415Nonecode59Heavy Duty Copper Terminal Long Barrel( COMMON Electrical SR of 2023-24, 50 Sqmm Copper Terminal, Apprx Wt: 26 GmNo64.9664.9648.0FalseNoneNoneFalseNoneFalse3118.080
3342184117415Nonecode60Brass Cable Gland. 40 mmNo106.4106.416.0FalseNoneNoneFalseNoneFalse1702.40
17192950820001NoneNoneOther Works11E - Elect Work RESTAURANTS - 02 No680988.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3342185117416Nonecode01Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm73.9273.92140.0FalseNoneNoneFalseNoneFalse10348.80
3342186117416Nonecode02Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm87.3687.36240.0FalseNoneNoneFalseNoneFalse20966.40
3342187117416Nonecode03Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32 mm dia 2.5 mm thickm115.36115.36120.0FalseNoneNoneFalseNoneFalse13843.20
3342188117416Nonecode04Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm76.1676.16180.0FalseNoneNoneFalseNoneFalse13708.80
3342189117416Nonecode05Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm88.4888.48160.0FalseNoneNoneFalseNoneFalse14156.80
3342190117416Nonecode06Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32mm dia 2.5mm thickm110.88110.8820.0FalseNoneNoneFalseNoneFalse2217.60
3342191117416Nonecode07Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20 mm deep Junction boxEach54.8854.8830.0FalseNoneNoneFalseNoneFalse1646.40
3342192117416Nonecode08Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mm deep Junction boxEach62.7262.7230.0FalseNoneNoneFalseNoneFalse1881.60
3342193117416Nonecode09Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )No131.04131.0424.0FalseNoneNoneFalseNoneFalse3144.960
3342194117416Nonecode10Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Way TP & NEach4522.564522.564.0FalseNoneNoneFalseNoneFalse18090.240
3342195117416Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2WayEach154.56154.5620.0FalseNoneNoneFalseNoneFalse3091.20
3342196117416Nonecode12Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4-5WayEach198.24198.248.0FalseNoneNoneFalseNoneFalse1585.920
3342197117416Nonecode13Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8WayEach292.32292.3212.0FalseNoneNoneFalseNoneFalse3507.840
3342198117416Nonecode14Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12WayEach357.28357.2816.0FalseNoneNoneFalseNoneFalse5716.480
3342199117416Nonecode15Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 ModuleEach153.44153.4420.0FalseNoneNoneFalseNoneFalse3068.80
3342200117416Nonecode16Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4 ModuleEach196.0196.08.0FalseNoneNoneFalseNoneFalse1568.00
3342201117416Nonecode17Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8 ModuleEach318.08318.0812.0FalseNoneNoneFalseNoneFalse3816.960
3342202117416Nonecode18Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 ModuleEach385.28385.2816.0FalseNoneNoneFalseNoneFalse6164.480
3342203117416Nonecode19Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch boxPoint301.28301.2820.0FalseNoneNoneFalseNoneFalse6025.60
3342204117416Nonecode20Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxPoint424.48424.4838.0FalseNoneNoneFalseNoneFalse16130.240
3342205117416Nonecode21Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxPoint621.6621.644.0FalseNoneNoneFalseNoneFalse27350.40
3342206117416Nonecode22Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps one way SwitchEach114.24114.24142.0FalseNoneNoneFalseNoneFalse16222.080
3342207117416Nonecode23Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps 3way socketEach191.52191.5240.0FalseNoneNoneFalseNoneFalse7660.80
3342208117416Nonecode24Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Stepped Fan Regulator Two ModuleEach399.84399.8424.0FalseNoneNoneFalseNoneFalse9596.160
3342209117416Nonecode25Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32Amps DP switchEach365.12365.1212.0FalseNoneNoneFalseNoneFalse4381.440
3342210117416Nonecode26Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6/16Amps universal socketEach264.32264.3212.0FalseNoneNoneFalseNoneFalse3171.840
3342211117416Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.12580.0FalseNoneNoneFalseNoneFalse16889.60
3342212117416Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.04660.0FalseNoneNoneFalseNoneFalse31046.40
3342213117416Nonecode29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.56540.0FalseNoneNoneFalseNoneFalse38102.40
3342214117416Nonecode30Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmmm103.03103.0360.0FalseNoneNoneFalseNoneFalse6181.80
3342215117416Nonecode31Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100 AEach9558.089558.082.0FalseNoneNoneFalseNoneFalse19116.160
3342216117416Nonecode32Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100A to 250A TPDT/COSEach500.64500.642.0FalseNoneNoneFalseNoneFalse1001.280
3342217117416Nonecode33Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-FOUR Pole,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100Amps 25kA.Each9505.449505.442.0FalseNoneNoneFalseNoneFalse19010.880
3342218117416Nonecode34Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.6828.0FalseNoneNoneFalseNoneFalse23175.040
3342219117416Nonecode35Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.2710.0FalseNoneNoneFalseNoneFalse34092.70
3342220117416Nonecode36Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each10432.810432.82.0FalseNoneNoneFalseNoneFalse20865.60
3342221117416Nonecode37Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.86.0FalseNoneNoneFalseNoneFalse3460.80
3342222117416Nonecode38Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.4860000.0FalseNoneNoneFalseNoneFalse28800.00
3342223117416Nonecode39Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.81.0FalseNoneNoneFalseNoneFalse2760.80
3342224117416Nonecode40Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.48.0FalseNoneNoneFalseNoneFalse3539.20
3342225117416Nonecode41Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED light fighting 1 x4'- 20/22 wEach772.8772.836.0FalseNoneNoneFalseNoneFalse27820.80
3342226117416Nonecode42Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )9 W , 6500 KEach172.48172.4810.0FalseNoneNoneFalseNoneFalse1724.80
3342227117416Nonecode43Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 70W,Each6711.046711.042.0FalseNoneNoneFalseNoneFalse13422.080
3342228117416Nonecode44Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete...( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each1671.041671.044.0FalseNoneNoneFalseNoneFalse6684.160
3342229117416Nonecode45Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )48" Sweep 5 Star (1200mm)Each2998.242998.2412.0FalseNoneNoneFalseNoneFalse35978.880
3342230117416Nonecode46Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 LEach13360.4813360.482.0FalseNoneNoneFalseNoneFalse26720.960
3342231117416Nonecode47Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Using 32mm dia G.I.PipeEach1450.41450.42.0FalseNoneNoneFalseNoneFalse2900.80
3342232117416Nonecode48Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )On wall / ceiling / Rafter / GirdersEach136.64136.6436.0FalseNoneNoneFalseNoneFalse4919.040
3342233117416Nonecode49Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each352.8352.824.0FalseNoneNoneFalseNoneFalse8467.20
3342234117416Nonecode50Extra length of GI pipe of class B 19mm dia for down rod.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ).( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each220.64220.6424.0FalseNoneNoneFalseNoneFalse5295.360
3342235117416Nonecode51Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each551.04551.048.0FalseNoneNoneFalseNoneFalse4408.320
3342236117416Nonecode52Erection charges for fixing a ... litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )upto 30 LitresEach743.68743.682.0FalseNoneNoneFalseNoneFalse1487.360
3342237117416Nonecode53Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges - Maerial cost Rs.Set5850.885850.884.0FalseNoneNoneFalseNoneFalse23403.520
3342238117416Nonecode54Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges - Labour charges Rs,Km2364.322364.324.0FalseNoneNoneFalseNoneFalse9457.280
3342239117416Nonecode55Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractorm375.2375.240.0FalseNoneNoneFalseNoneFalse15008.00
3342240117416Nonecode56Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975 - 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km200449.76200449.760.1FalseNoneNoneFalseNoneFalse20044.9760
3342241117416Nonecode57Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff-35 to 95 SqmmKm34875.6834875.680.1FalseNoneNoneFalseNoneFalse3487.5680
3342242117416Nonecode58Heavy Duty Copper Terminal Long Barrel.-25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.248.0FalseNoneNoneFalseNoneFalse241.920
3342243117416Nonecode59Heavy Duty Copper Terminal Long Barrel.-50 Sqmm Copper Terminal, Apprx Wt: 26 GmNo64.9664.9624.0FalseNoneNoneFalseNoneFalse1559.040
3342244117416Nonecode60Brass Cable Gland-40 mmNo106.4106.48.0FalseNoneNoneFalseNoneFalse851.20
17192950820001NoneNoneOther Works14E - Electrification - Public Toilet415864.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3342245117417Nonecode01Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. (COMMON Electrical SR of 2023-24, Part - III , Utilization (PWD Electrical ))19/20mm dia 2mm thickm73.9273.92130.0FalseNoneNoneFalseNoneFalse9609.60
3342246117417Nonecode02Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. (COMMON Electrical SR of 2023-24, Part - III , Utilization (PWD Electrical ))25mm dia 2mm thickm87.3687.36120.0FalseNoneNoneFalseNoneFalse10483.20
3342247117417Nonecode03Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. (COMMON Electrical SR of 2023-24, Part - III , Utilization (PWD Electrical ))32 mm dia 2.5 mm thickm115.36115.3630.0FalseNoneNoneFalseNoneFalse3460.80
3342248117417Nonecode04Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20mm dia 2mm thickm76.1676.1690.0FalseNoneNoneFalseNoneFalse6854.40
3342249117417Nonecode05Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm88.4888.48130.0FalseNoneNoneFalseNoneFalse11502.40
3342250117417Nonecode06Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32mm dia 2.5mm thickm110.88110.8820.0FalseNoneNoneFalseNoneFalse2217.60
3342251117417Nonecode07Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20 mm deep Junction boxEach54.8854.8830.0FalseNoneNoneFalseNoneFalse1646.40
3342252117417Nonecode08Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mm deep Junction boxEach62.7262.7230.0FalseNoneNoneFalseNoneFalse1881.60
3342253117417Nonecode09Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Way TP & NEach4522.564522.562.0FalseNoneNoneFalseNoneFalse9045.120
3342254117417Nonecode10Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2WayEach154.56154.5625.0FalseNoneNoneFalseNoneFalse3864.00
3342255117417Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4-5WayEach198.24198.246.0FalseNoneNoneFalseNoneFalse1189.440
3342256117417Nonecode12Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8WayEach292.32292.326.0FalseNoneNoneFalseNoneFalse1753.920
3342257117417Nonecode13Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12WayEach357.28357.286.0FalseNoneNoneFalseNoneFalse2143.680
3342258117417Nonecode14Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 ModuleEach153.44153.4425.0FalseNoneNoneFalseNoneFalse3836.00
3342259117417Nonecode15Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4 ModuleEach196.0196.06.0FalseNoneNoneFalseNoneFalse1176.00
3342260117417Nonecode16Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8 ModuleEach318.08318.086.0FalseNoneNoneFalseNoneFalse1908.480
3342261117417Nonecode17Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 ModuleEach385.28385.286.0FalseNoneNoneFalseNoneFalse2311.680
3342262117417Nonecode18Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch boxPoint301.28301.2815.0FalseNoneNoneFalseNoneFalse4519.20
3342263117417Nonecode19Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxPoint424.48424.4826.0FalseNoneNoneFalseNoneFalse11036.480
3342264117417Nonecode20Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxPoint621.6621.620.0FalseNoneNoneFalseNoneFalse12432.00
3342265117417Nonecode21Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps one way SwitchEach114.24114.2477.0FalseNoneNoneFalseNoneFalse8796.480
3342266117417Nonecode22Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps 3way socketEach191.52191.5216.0FalseNoneNoneFalseNoneFalse3064.320
3342267117417Nonecode23Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32Amps DP switchEach365.12365.1210.0FalseNoneNoneFalseNoneFalse3651.20
3342268117417Nonecode24Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6/16Amps universal socketEach264.32264.3210.0FalseNoneNoneFalseNoneFalse2643.20
3342269117417Nonecode25Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.12200.0FalseNoneNoneFalseNoneFalse5824.00
3342270117417Nonecode26Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.04300.0FalseNoneNoneFalseNoneFalse14112.00
3342271117417Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.56300.0FalseNoneNoneFalseNoneFalse21168.00
3342272117417Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmmm103.03103.0340.0FalseNoneNoneFalseNoneFalse4121.20
3342273117417Nonecode29Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100 AEach9558.089558.081.0FalseNoneNoneFalseNoneFalse9558.080
3342274117417Nonecode30Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100A to 250A TPDT/COSEach500.64500.641.0FalseNoneNoneFalseNoneFalse500.640
3342275117417Nonecode31Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-FOUR Pole,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100Amps 25kA.Each9505.449505.441.0FalseNoneNoneFalseNoneFalse9505.440
3342276117417Nonecode32Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.6810.0FalseNoneNoneFalseNoneFalse8276.80
3342277117417Nonecode33Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPNEach3409.273409.274.0FalseNoneNoneFalseNoneFalse13637.080
3342278117417Nonecode34Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each10432.810432.82.0FalseNoneNoneFalseNoneFalse20865.60
3342279117417Nonecode35Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Each576.8576.86.0FalseNoneNoneFalseNoneFalse3460.80
3342280117417Nonecode36Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )16SWGSq CM0.480.48100000.0FalseNoneNoneFalseNoneFalse48000.00
3342281117417Nonecode37Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )100Amps 4x30x6mm Aluminium Stripsm2760.82760.81.0FalseNoneNoneFalseNoneFalse2760.80
3342282117417Nonecode38Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mmm442.4442.48.0FalseNoneNoneFalseNoneFalse3539.20
3342283117417Nonecode39Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED light fighting 1 x4'- 20/22 wEach772.8772.816.0FalseNoneNoneFalseNoneFalse12364.80
3342284117417Nonecode40Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )9 W , 6500 KEach172.48172.4829.0FalseNoneNoneFalseNoneFalse5001.920
3342285117417Nonecode41Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED Streetlight 70W,Each6711.046711.044.0FalseNoneNoneFalseNoneFalse26844.160
3342286117417Nonecode42Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete...( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Each1671.041671.048.0FalseNoneNoneFalseNoneFalse13368.320
3342287117417Nonecode43Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Using 32mm dia G.I.PipeEach1450.41450.44.0FalseNoneNoneFalseNoneFalse5801.60
3342288117417Nonecode44Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )On wall / ceiling / Rafter / GirdersEach136.64136.6416.0FalseNoneNoneFalseNoneFalse2186.240
3342289117417Nonecode45Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each551.04551.048.0FalseNoneNoneFalseNoneFalse4408.320
3342290117417Nonecode46Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges Maerial cost Rs.Set5850.885850.882.0FalseNoneNoneFalseNoneFalse11701.760
3342291117417Nonecode47Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges Labour charges Rs,Km2364.322364.322.0FalseNoneNoneFalseNoneFalse4728.640
3342292117417Nonecode48Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractorm375.2375.220.0FalseNoneNoneFalseNoneFalse7504.00
3342293117417Nonecode49Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975 - 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km200449.76200449.760.14FalseNoneNoneFalseNoneFalse28062.96640
3342294117417Nonecode50Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm34875.6834875.680.14FalseNoneNoneFalseNoneFalse4882.59520
3342295117417Nonecode51Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.248.0FalseNoneNoneFalseNoneFalse241.920
3342296117417Nonecode52Heavy Duty Copper Terminal Long Barrel 50 Sqmm Copper Terminal, Apprx Wt: 26 GmNo64.9664.9624.0FalseNoneNoneFalseNoneFalse1559.040
3342297117417Nonecode53Brass Cable Gland-40 mmNo106.4106.48.0FalseNoneNoneFalseNoneFalse851.20
17192950820004NoneNoneOther Works15E Electrical Work SECURITY HOUSE58420.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3342298117418Nonecode01Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm87.3687.3650.0FalseNoneNoneFalseNoneFalse4368.00
3342299117418Nonecode02Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25mm dia 2mm thickm88.4888.4835.0FalseNoneNoneFalseNoneFalse3096.80
3342300117418Nonecode03Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )19/20 mm deep Junction boxEach54.8854.885.0FalseNoneNoneFalseNoneFalse274.40
3342301117418Nonecode04Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )25 mm deep Junction boxEach62.7262.725.0FalseNoneNoneFalseNoneFalse313.60
3342302117418Nonecode05Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )No131.04131.043.0FalseNoneNoneFalseNoneFalse393.120
3342303117418Nonecode06Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )II - Double Door ,8 Way SP & NEach2076.482076.481.0FalseNoneNoneFalseNoneFalse2076.480
3342304117418Nonecode07Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2WayEach154.56154.562.0FalseNoneNoneFalseNoneFalse309.120
3342305117418Nonecode08Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8WayEach292.32292.321.0FalseNoneNoneFalseNoneFalse292.320
3342306117418Nonecode09Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12WayEach357.28357.282.0FalseNoneNoneFalseNoneFalse714.560
3342307117418Nonecode10Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 ModuleEach153.44153.442.0FalseNoneNoneFalseNoneFalse306.880
3342308117418Nonecode11Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8 ModuleEach318.08318.081.0FalseNoneNoneFalseNoneFalse318.080
3342309117418Nonecode12Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 ModuleEach385.28385.282.0FalseNoneNoneFalseNoneFalse770.560
3342310117418Nonecode13Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch boxPoint301.28301.285.0FalseNoneNoneFalseNoneFalse1506.40
3342311117418Nonecode14Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxPoint424.48424.486.0FalseNoneNoneFalseNoneFalse2546.880
3342312117418Nonecode15Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps one way SwitchEach114.24114.2416.0FalseNoneNoneFalseNoneFalse1827.840
3342313117418Nonecode16Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6Amps 3way socketEach191.52191.525.0FalseNoneNoneFalseNoneFalse957.60
3342314117418Nonecode17Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )32Amps DP switchEach365.12365.122.0FalseNoneNoneFalseNoneFalse730.240
3342315117418Nonecode18Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )6/16Amps universal socketEach264.32264.322.0FalseNoneNoneFalseNoneFalse528.640
3342316117418Nonecode19Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )1.5 sqmmm29.1229.1280.0FalseNoneNoneFalseNoneFalse2329.60
3342317117418Nonecode20Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmmm47.0447.0480.0FalseNoneNoneFalseNoneFalse3763.20
3342318117418Nonecode21Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmmm70.5670.5660.0FalseNoneNoneFalseNoneFalse4233.60
3342319117418Nonecode22Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DPEach827.68827.683.0FalseNoneNoneFalseNoneFalse2483.040
3342320117418Nonecode23Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach772.8772.87.0FalseNoneNoneFalseNoneFalse5409.60
3342321117418Nonecode24Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )LED Streetlight 70W,Each6711.046711.041.0FalseNoneNoneFalseNoneFalse6711.040
3342322117418Nonecode25Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Using 32mm dia G.I.PipeEach1450.41450.41.0FalseNoneNoneFalseNoneFalse1450.40
3342323117418Nonecode26Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )On wall / ceiling / Rafter / GirdersEach136.64136.647.0FalseNoneNoneFalseNoneFalse956.480
3342324117418Nonecode27Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975 - 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km132164.48132164.480.06FalseNoneNoneFalseNoneFalse7929.86880
3342325117418Nonecode28Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm23392.3223392.320.06FalseNoneNoneFalseNoneFalse1403.53920
3342326117418Nonecode29Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 GmNo30.2430.248.0FalseNoneNoneFalseNoneFalse241.920
3342327117418Nonecode30Brass Cable Gland 25 mmNo88.4888.482.0FalseNoneNoneFalseNoneFalse176.960
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194882040000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194882040000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194882040000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194882040000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194882040000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17195530330000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17195530490000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17195530760000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17195530850000NoneNoneELIGIBILITYThe conditional Tender will not be accepted.None
17195530940000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17195531020000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt orders.None
17195531090000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Bangalore dated 01.01.2007 and Government letter no PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fund.None
17195531190000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17195531280000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasons.None
17195531360000NoneNoneELIGIBILITYIn the case of the death of the contractor after executing the agreement / commencement of the work, his legal heir, if is an eligible registered contractor and is willing can execute and compete the work at the accepted tender rates irrespective of the cost of the work.None
17195531460000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with the Conditions of Contract.None
17195531590000NoneNoneELIGIBILITYContractor should carryout additional test required to test the suitability of materials.None
17195531740000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity. Contractor should indemnify the client to that extent.None
17195531860000NoneNoneELIGIBILITYAll the items in the tender include all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and conveyance of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer- in-charge of this work.None
17195531990000NoneNoneELIGIBILITYContractor should follow strictly the prevailing rules of labour act.None
17195532110000NoneNoneELIGIBILITYContractor should take all precautions to ensure that no damage is caused to the existing structures which have been constructed by other agencies during project execution. If any damage is caused, it has to be rectified at his own risk and cost.None
17195532210000NoneNoneELIGIBILITYThe cost of the Tender processing fees shall not be refundable.None
17195532310000NoneNoneELIGIBILITYFurther particulars, if any, required by the Contractor can be had from the office of the Executive Engineer, during office hours on all working days.None
17195532410000NoneNoneELIGIBILITYMaterials like steel, cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority before use on the work at their own cost. Department will not supply any materials.None
17195532500000NoneNoneELIGIBILITYThe contractors assessed available tender capacity will be calculated as per the clause 3.6 of kw-4 tender document Attached.None
17195532600000NoneNoneELIGIBILITYFormation levels and other data furnished are bare minimum the contractor should make all efforts to validate and to get additional data if required at his own cost.None
17195532720000NoneNoneELIGIBILITYAll precautions should be taken by the contractor so that there are no damages to such public/ private properties. Also the Contractor should take all precautionary measures to avoid any damage to the utilities during excavation as well as utility shifting. To that extent the contractor should indemnify the client.None
17195532800000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and program of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completion.None
17195532920000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documents KW-4 K.P.W.D. and further orders there on.None
17195533010000NoneNoneELIGIBILITYContractors should be registered with KPWD/CPWD/Port Trust and e-procurement registered Contractor.None
17195533110000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the same originals should be produced to the Executive Engineer (at the time of Technical Bid Opening) who reserves the right to verify the documents before approval.None
17195533210000NoneNoneELIGIBILITYWork shall be executed as per standard specifications.None
17195533360000NoneNoneELIGIBILITYBidder should have valid Registration with Employees Provident Fund Organization under EPF and Miscellaneous Provisions Act, 1952. (Should Attach Latest Copies)None
17195533460000NoneNoneELIGIBILITYWork Done Certificates issued by not below the rank of Executive EngineerNone
17195533640000NoneNoneELIGIBILITYGoods and Service Tax (GST), The contractor shall be allowed to bill GST complying with GST rules at prevailing rate in running account bill and for reimbursement by the Employer, Tax invoice is required to be submitted and Information in GST should appear/display.None
17195533760000NoneNoneELIGIBILITYGST will be paid separately as per Government Oder.None
17195533920000NoneNoneELIGIBILITYThe Increase in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delays as determined by the authority while granting the extension of time.None
17195534180000NoneNoneELIGIBILITYThe Tenderer shall obtain the work done certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verificationNone
17195534350000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire commitment Agreement for the Machinery, Bank Guarantee and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verificationNone
17195534480000NoneNoneELIGIBILITYBidders should quote the rate exclusive of GST only and GST Declaration Certificate Duly signed by contractor should upload in the portalNone
17195534690000NoneNoneELIGIBILITYThe period for completion of the work is 24 months.None
17195534890000NoneNoneELIGIBILITYThe defect liability period is 365 daysNone
17201625230000NoneNoneELIGIBILITYEstimate rates are excluding GST as per Common SR 2023-24 and prevailing GST (18% of Amount Put to tender) amount is kept in form of Lump sum in sanctioned estimate according to guidelines in Common SR (GO:PWD 51 RDF 2019 Bangaluru Dt:18.03.2022). Therefore, amount put to Tender and ECV amount are excluding GST. KPPP-PORTAL format has No Options to add GST Separately at stage of Draft Tender Schedule Process for Over All amount put to Tender, tender has been inviting through an Option with INCLUSIVE. But the item wise rates do not include GST. Hence, GST will be paid separately for the quoted amount accordingly. Declaration Certificate must be attached mandatorily.None
17225119770000NoneNoneELIGIBILITYInterested bidders are requested to furnish joint inspection letter from AEE/AE Port and Fisheries Sub Division, Mangalore regarding visit of Construction site.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTendered WorksPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format 7
NoneNoneNoneNoneSatisfactorily completed (at least 90% of the Contract Value), as prime contractor, at least One similar work such as Harbour Development work of value not less than Rs.1831.62 lakhs. (Usually not less than 50% of estimated value of contract)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one financial year, in the last five years, the following minimum quantities of work RCC or PCC 9541.00 Cum, Bored Cast in Situ Pile 940.00 Rmtr, Diaphragm Wall or Anchor Wall 1610.00 Sqm, TMT Steel 529.00 Tonne, Embankment 11020.00 Cum, GSB or WBM or WMM 6265.00 Cum.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneRegistration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBidder should have valid Registration with Employees Provident Fund Organization under EPF and Miscellaneous Provisions Act, 1952. (Should Attach Latest Copies)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid EPF Certificate
NoneNoneNoneNonePrincipal Place of BusinessCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Declaration by the bidder on the letterhead
NoneNoneNoneNoneNew WorkCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information of the works for which Tender acceptance letters are received
NoneNoneNoneNoneQualification and experience of the key technical and Management personnel in permanent employment with the Tenderer and those that are proposed to be deployed on this work, if work is awarded.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bio data of the personnel
NoneNoneNoneNoneThe proposed methodology and program of construction, backed with equipment planning and deployment, duly supported with broad calculations and quality control procedures proposed to be adopted, justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- CPM/PERT Chart
NoneNoneNoneNoneValue at 2023-24 price level, of existing commitments and on-going works to be executed during the next 12 months (Financial commitment of previous years shall be given a weight of 10% per year to bring them to the price level of the 2023-24), (Month wise commitment shall be furnished).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement of the letter head of the tenderer
NoneNoneNoneNoneSite Labs: Contractor should establish their own Laboratory with qualified personnel.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Site Labs : Contractor should establish their own Laboratory with qualified personnel.
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess required valid license for executing Electrical works and should have executed similar Electrical works totaling Rs.44.24 Lakhs (usually not less than 50% of the electrical works) in any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- MOU copy with identified sub-contractor along with Work done certificate of sub-contractor issued by not below the rank of Executive Engineer
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess required valid license for executing Dredging works and should have executed similar Dredging works totaling Rs.63.34 Lakhs (usually not less than 50% of the dredging works) in any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- MOU copy with identified sub-contractor along with Work done certificate of sub-contractor issued by not below the rank of Executive Engineer
NoneNoneNoneNoneAvailability by owning at least 50% of required / specified key and initial equipment for this work The remaining 50% can be deployed on lease / line basis for all works provided the relevant document. Excavators - 6 (3 own & 3 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneTippers - 10 (5 own & 5 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNonePiling Equipment- 6 (3 own & 3 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneBatch Mix Concrete Mixers-2 No (1 own & 1 Hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneTransit Mixer- 4 (2 Own & 2 Hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNone12T capacity crane - 2 (1 Own & 1 Hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneHot Mix Plant/ Batch Mix Plant - O2 (1 Own & 1 Hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneStatic Road Roller 2 No (1 own & 1 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneVibratory Road Roller 2 No (1 own & 1 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneMechanical Paver Finisher 2 No (1 own & 1 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under: Assessed available tender capacity-(AxNx1.5 - B) where A-Maximum value of civil engineering works executed in any one year during the last five years (updated to 2024-25 price level) taking into account the completed as well as works in progress. N-Number of years prescribed for completion of the works for which tenders are invited 2 years (24 Months) B- Value, at 2024-25 price level, of existing commitments and on-going works to be completed during the next 2 years (24 Months) (period of completion of the works for which Tenders are invited)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EXISTING & ON-GOING WORK DETIALS
NoneNoneNoneNoneAssessed Tender Capacity shall be more than the Tender AmountFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessment on the letter head of the tenderer
NoneNoneNoneNoneMaximum of Civil Engineering works executed in any one year during the last five years (updated to 2024-25 price level) taking into account the completed as well as works in progress. (Financial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Statement of the letter head of the tenderer
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e. 2019-20 to 2023-24 (a) achieved in at least two financial years a minimum financial turnover (in all classes of civil Engineering construction works only) of Rs.3663.25 lakhs (Usually not less than two times the estimated annual payments under this contract)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of not less than Rs.457.91 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually the equivalent of the estimated cash flow for three months in the peak construction period)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneThe tenderer shall furnish, as part of his tender, earnest money deposit as shown in the column 4 of the table of the IFT for this particular work. The Earnest money Deposit shall be in two parts. Part (1) Rs.1,00,000.00 by e-payment. Part (2) Balance EMD 35,63,000.00 shall be in the form of Bank Guarantee in prescribed format obtained from any Nationalized/Scheduled Bank in favour of Executive Engineer Port and Fisheries Division, Udupi. The tenderer should upload the scanned copy of the original Part-2 of the EMD in the e-portal and shall be delivered to the Executive Engineer on or before the prescribed date of opening of technical bid.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by Nationalized or Scheduled Bank
NoneNoneNoneNoneCommitted worksOthersOther
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information on works which are yet to be completed
NoneNoneNoneNoneThe period for completion of the work is months.24 monthsOthersOther
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The period for completion of the work is months.24 months
NoneNoneNoneNoneThe defect liability period is 365 daysOthersOther
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The defect liability period is 365 days
NoneNoneNoneNoneSite Labs :Contractor should establish their own Laboratory with qualified personnel.OthersOther
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration CertificateTrueTechnical Bid
GST Declaration CertificateTrueTechnical Bid
Turnover Details -P&L, Balance sheet, IT returns filed details filed copyTrueTechnical Bid
Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copiesTrueTechnical Bid
LOC/Banker Certificate - In prescribed format onlyTrueTechnical Bid
EMD document other than E-paymentTrueTechnical Bid
Work done Certificate /EXISTING & ON-GOING WORK DETIALSTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Other WorksDakshina KannadaMangaluruMangaloreMANGALORE3RD STAGE MANGALORE FISHERY HARBOURNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1722512064000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executive Engineer, Port and Fisheries Division, Udupi
streetNone
cityudupi
stateKarnataka
pin576103
tenderRecallDTONone