| 3697133 | 136002 | None | code01 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Refer Appendix-I For Formwork, Centering, Scaffolding of columns is 70% (Pg No 111 of Common SR 2023-24) | Cum | 11469.9 | 11469.9 | 1.2834 | False | None | None | False | None | False | 14720.46966 | 0 |
| 3697134 | 136002 | None | code02 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 1) Refer Appendix-I For Formwork, Centering, Scaffolding of beams & lintels is 60% (Pg No 111 of Common SR 2023-24) | Cum | 10806.9 | 10806.9 | 2.6241 | False | None | None | False | None | False | 28358.38629 | 0 |
| 3697135 | 136002 | None | code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates1) Refer Appendix-I For Formwork, Centering, Scaffolding of Roof Slab is 50% (Pg No 111of Common SR 2023-24) | Cum | 10143.9 | 10143.9 | 5.7732 | False | None | None | False | None | False | 58562.76348 | 0 |
| 3697136 | 136002 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. | Tonne | 92140.71 | 92140.71 | 0.7339 | False | None | None | False | None | False | 67622.067069 | 0 |
| 3697137 | 136002 | None | code05 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8208.07 | 8208.07 | 9.5517 | False | None | None | False | None | False | 78401.022219 | 0 |
| 3697138 | 136002 | None | code06 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 10.8 | False | None | None | False | None | False | 10857.024 | 0 |
| 3697139 | 136002 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 6596.12 | 6596.12 | 0.4402 | False | None | None | False | None | False | 2903.612024 | 0 |
| 3697140 | 136002 | None | code08 | Providing 15 mm cement plaster on rough side of single or half brick wallfinished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 359.47 | 359.47 | 76.1 | False | None | None | False | None | False | 27355.667 | 0 |
| 3697141 | 136002 | None | code09 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ) | Sqm | 396.55 | 396.55 | 60.375 | False | None | None | False | None | False | 23941.70625 | 0 |
| 3697142 | 136002 | None | code10 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge. | Sqm | 332.69 | 332.69 | 24.96 | False | None | None | False | None | False | 8303.9424 | 0 |
| 3697143 | 136002 | None | code11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 103.0 | 103.0 | 101.06 | False | None | None | False | None | False | 10409.18 | 0 |
| 3697144 | 136002 | None | code12 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 101779.45 | 101779.45 | 0.1349 | False | None | None | False | None | False | 13730.047805 | 0 |
| 3697145 | 136002 | None | code13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 188.49 | 188.49 | 105.84 | False | None | None | False | None | False | 19949.7816 | 0 |
| 3697146 | 136002 | None | code14 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge.(Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kgs | 503.67 | 503.67 | 5.04 | False | None | None | False | None | False | 2538.4968 | 0 |
| 3697147 | 136002 | None | code15 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 1017.64 | 1017.64 | 5.04 | False | None | None | False | None | False | 5128.9056 | 0 |
| 3697148 | 136002 | None | code16 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Mtr | 63.86 | 63.86 | 5.04 | False | None | None | False | None | False | 321.8544 | 0 |
| 3697149 | 136002 | None | code17 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. | Sqm | 3421.66 | 3421.66 | 5.04 | False | None | None | False | None | False | 17245.1664 | 0 |
| 3697150 | 136002 | None | code18 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. | Sqm | 1179.35 | 1179.35 | 27.808 | False | None | None | False | None | False | 32795.3648 | 0 |
| 3697151 | 136002 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 141.11 | 141.11 | 101.06 | False | None | None | False | None | False | 14260.5766 | 0 |
| 3697152 | 136002 | None | code20 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 179.22 | 179.22 | 60.375 | False | None | None | False | None | False | 10820.4075 | 0 |
| 3697153 | 136002 | None | code21 | Supplying capacitor type ceiling fan complete with down rod lades,shackle,canopies etc,for operatio non 230V,50 cycles. Singlephase AC supplyconforming to ISS-374-1979 and with double ball bearing system. | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 |
| 3697154 | 136002 | None | code22 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 2.0 | False | None | None | False | None | False | 244.0 | 0 |
| 3697155 | 136002 | None | code23 | Supplyingof.....feet PVC Batten with integrated LEDtube....Wwith highqualitydiffuser with Life of 25000 burning hours&70% lumen maintenance withCRI80 .Power Input:220 240V@50/60Hz&Powerfactor0.9alongwithCEapproved. 2years Warranty againstany manufacturing defect working understand ardelectrical condition
LED light fitting 1 x 4' - 20/22 W. | Each | 690.0 | 690.0 | 2.0 | False | None | None | False | None | False | 1380.0 | 0 |
| 3697156 | 136002 | None | code24 | Fixingof.....ATPST/change over switch/Contactor along with neutral link withs crews,bolts,nuts and wiring using required capacity wires and circuit labelling. | Each | 278.0 | 278.0 | 2.0 | False | None | None | False | None | False | 556.0 | 0 |
| 3697157 | 136002 | None | code25 | Supplying of TPST with rewirable porcelain channel sinS Menclosure .Made out of 14 SWG powder coated paint of approved colour. | Each | 4193.93 | 4193.93 | 2.0 | False | None | None | False | None | False | 8387.86 | 0 |
| 3697158 | 136002 | None | code26 | Supplying PVC flexible conduit pipe....mmdia fixing ons urface over inverted tapered wooden plugs orr phill plug sorraw lplug sand clamp edusing heavy gauge saddlesatan interval of 300 mm using NF screws and on either end of the pipe terminated completely | Each | 22.0 | 22.0 | 60.0 | False | None | None | False | None | False | 1320.0 | 0 |
| 3697159 | 136002 | None | code27 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.Cwall,including necessary raw lplugs,Machine/NF screws etc., complete.
10-12 Way | No | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 |
| 3697160 | 136002 | None | code28 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6Amps one way) | No | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
| 3697161 | 136002 | None | code29 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting backplate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. | No | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 |
| 3697162 | 136002 | None | code30 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multi strand copper wire with lowc onductor resistance single core in open or concealed system of wiring with specifiedIS-694:2010 1.5 mm2 | No | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 |
| 3697163 | 136002 | None | code31 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multi strand copper wire with lowc onductor resistance single core in open or concealed system of wiring with specifiedIS-694:2010 2.5 mm2 | No | 42.0 | 42.0 | 60.0 | False | None | None | False | None | False | 2520.0 | 0 |
| 3697164 | 136002 | None | code32 | Supplying 6A flush type socket and 6A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 2 Way | No | 128.0 | 128.0 | 2.0 | False | None | None | False | None | False | 256.0 | 0 |
| 3697165 | 136002 | None | code33 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. | No | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 |
| 3697166 | 136002 | None | code34 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. | No | 329.0 | 329.0 | 2.0 | False | None | None | False | None | False | 658.0 | 0 |
| 3697167 | 136002 | None | code35 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C'Typecurve,indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 40 A SP | No | 793.0 | 793.0 | 1.0 | False | None | None | False | None | False | 793.0 | 0 |
| 3697168 | 136002 | None | code36 | For Electrical & Hescom Charges | No | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 |
| 3697169 | 136002 | None | code37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | No | 167.0 | 167.0 | 5.04 | False | None | None | False | None | False | 841.68 | 0 |
| 3697170 | 136002 | None | code38 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm
C.P. brass pillar taps | No | 3174.46 | 3174.46 | 2.0 | False | None | None | False | None | False | 6348.92 | 0 |
| 3697171 | 136002 | None | code39 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge | No | 834.3 | 834.3 | 2.0 | False | None | None | False | None | False | 1668.6 | 0 |
| 3697172 | 136002 | None | code40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall | No | 187.46 | 187.46 | 10.0 | False | None | None | False | None | False | 1874.6 | 0 |
| 3697173 | 136002 | None | code41 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 500.0 | False | None | None | False | None | False | 4635.0 | 0 |