| 1722869846000 | 0 | None | None | Other Works | PROVIDING AND FIXING OF HIGH MASTS TO NEAR AISHA MASUTI AND NEAR HULLIGEMMA GUDI,CONSTRUCTION OF 2 CD AT ALAHALLI ROAD KACHAPURA BADAWANE AND CONSTRUCTION OF DRAIN FROM N A BIRADAR HOUSE TO ELIASA BENNESIRUR HOUSE IN ALMEL TOWN. | 1109209.69 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3697996 | 136065 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In All Types of Soil Depth Upto 3Mtrs | Cum | 105.06 | 105.06 | 18.081 | False | None | None | False | None | False | 1899.58986 | 0 | | 3697997 | 136065 | None | code02 | Construction of rock fill embankment with all lifts and lead Construction of rock fill embankment with broken hard rock fragments of size not exceeding 300 mm laid in layers not exceeding 500 mm thick including filling of surface voids with stone spalls, blinding top layer with granular material, rolled with vibratory road roller, all complete as per clause 313. | Cum | 150.38 | 150.38 | 2.646 | False | None | None | False | None | False | 397.90548 | 0 | | 3697998 | 136065 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 1.323 | False | None | None | False | None | False | 8161.15041 | 0 | | 3697999 | 136065 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Refer Appendix-I For Formwork, Centering, Scaffolding of other type Footing is 3% (Pg No 111 of Common SR 2023-24) | Cum | 7033.76 | 7033.76 | 3.888 | False | None | None | False | None | False | 27347.25888 | 0 | | 3698000 | 136065 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Refer Appendix-I For Formwork, Centering, Scaffolding of Columns is 70% (Pg No 111 of Common SR 2023-24) | Cum | 11609.13 | 11609.13 | 1.92 | False | None | None | False | None | False | 22289.5296 | 0 | | 3698001 | 136065 | None | code06 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 92140.71 | 92140.71 | 0.5227 | False | None | None | False | None | False | 48161.949117 | 0 | | 3698002 | 136065 | None | code07 | Fabrication, Supplying, Erection, Testing and Commissioning of ...... ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top
section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete.(excluding foundation) as per technical data. 12 m/12.5 m - Top 100 mm and Bottom 310 mm dia | Each | 134930.0 | 134930.0 | 2.0 | False | None | None | False | None | False | 269860.0 | 0 | | 3698003 | 136065 | None | code08 | Supply of LED Streetlight luminaire with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 70 W System Power consumption. LED Efficiency greaterthan 130lm/w, nominal CRI greater than 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/ Lumileds/ Osram make LED Source. (PWD Electrical SR 2023-24 It no 11.8.3) 120w LED street light - work execution as per engineer in charge | Each | 11079.71 | 11079.71 | 12.0 | False | None | None | False | None | False | 132956.52 | 0 | | 3698004 | 136065 | None | code09 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 166.86 | 166.86 | 12.0 | False | None | None | False | None | False | 2002.32 | 0 | | 3698005 | 136065 | None | code10 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 | Mtr | 280.16 | 280.16 | 110.0 | False | None | None | False | None | False | 30817.6 | 0 | | 3698006 | 136065 | None | code11 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130 1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100V as per IS 694 2010 | Mtr | 201.88 | 201.88 | 110.0 | False | None | None | False | None | False | 22206.8 | 0 | | 3698007 | 136065 | None | code12 | Fabricating supplying and mounting MS box made out… SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer pain and finally finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete-14 SWG | Sq CM | 0.51 | 0.51 | 4000.0 | False | None | None | False | None | False | 2040.0 | 0 | | 3698008 | 136065 | None | code13 | Extra length of GI pipe of class B 19mm dia for down rod. | Mtr | 202.91 | 202.91 | 70.0 | False | None | None | False | None | False | 14203.7 | 0 | | 3698009 | 136065 | None | code14 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers .63 A | Each | 161.71 | 161.71 | 6.0 | False | None | None | False | None | False | 970.26 | 0 | | 3698010 | 136065 | None | code15 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A DP | Each | 1135.06 | 1135.06 | 2.0 | False | None | None | False | None | False | 2270.12 | 0 | | 3698011 | 136065 | None | code16 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary\ bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.60 to 70 A | Each | 6302.57 | 6302.57 | 2.0 | False | None | None | False | None | False | 12605.14 | 0 | | 3698012 | 136065 | None | code17 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. | Each | 2384.45 | 2384.45 | 2.0 | False | None | None | False | None | False | 4768.9 | 0 | | 3698013 | 136065 | None | code18 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. | Each | 4988.29 | 4988.29 | 2.0 | False | None | None | False | None | False | 9976.58 | 0 | | 3698014 | 136065 | None | code19 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 40 x 40 x 6 mm | Mtr | 314.15 | 314.15 | 8.0 | False | None | None | False | None | False | 2513.2 | 0 | | 3698015 | 136065 | None | code20 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 530.45 | 530.45 | 6.0 | False | None | None | False | None | False | 3182.7 | 0 | | 3698016 | 136065 | None | code21 | Chemical earthing for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achiveing ohmic value less than one ohm, Using 6ft. Copper bonded rod with backfill compound | Kit | 6416.9 | 6416.9 | 2.0 | False | None | None | False | None | False | 12833.8 | 0 | | 3698017 | 136065 | None | code22 | Earth work excavation for Foundation by mechanical means for all works depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for euse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 92.5 | False | None | None | False | None | False | 9718.05 | 0 | | 3698018 | 136065 | None | code23 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 2.1.4 Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 8.705 | False | None | None | False | None | False | 55742.55455 | 0 | | 3698019 | 136065 | None | code24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. 1) Refer Appendix-I For Formwork, Centering, Scaffolding of Foundation, Sub structure of Cross drainages 5% (Pg No 115 of Common SR 2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7170.34 | 7170.34 | 8.065 | False | None | None | False | None | False | 57828.7921 | 0 | | 3698020 | 136065 | None | code25 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 1) Refer Appendix-I For Formwork Cement Concrete Drain Walls 35% M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9218.0 | 9218.0 | 17.56 | False | None | None | False | None | False | 161868.08 | 0 | | 3698021 | 136065 | None | code26 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a Buildings | Tonne | 92140.71 | 92140.71 | 2.05 | False | None | None | False | None | False | 188888.4555 | 0 | | 3698022 | 136065 | None | code27 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 13.5 | False | None | None | False | None | False | 3698.73 | 0 |
|