| 1722860851000 | 0 | None | None | Other Works | CONSTRUCTION OF R O PLANT AT WARD NO 13 14 AND 16 IN KOLHAR TOWN | 1528504.14 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3696169 | 135920 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In All Types of Soil Depth Upto 3Mtrs | Cum | 105.06 | 105.06 | 21.204 | False | None | None | False | None | False | 2227.69224 | 0 | | 3696170 | 135920 | None | code02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 273.98 | 273.98 | 15.671 | False | None | None | False | None | False | 4293.54058 | 0 | | 3696171 | 135920 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 3.264 | False | None | None | False | None | False | 20134.53888 | 0 | | 3696172 | 135920 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 20.3946 | False | None | None | False | None | False | 117867.123618 | 0 | | 3696173 | 135920 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6915.79 | 6915.79 | 3.016 | False | None | None | False | None | False | 20858.02264 | 0 | | 3696174 | 135920 | None | code06 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm | Sqm | 1114.46 | 1114.46 | 51.33 | False | None | None | False | None | False | 57205.2318 | 0 | | 3696175 | 135920 | None | code07 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 441.87 | 441.87 | 46.4 | False | None | None | False | None | False | 20502.768 | 0 | | 3696176 | 135920 | None | code08 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.050 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete(50mm dia0 | m | 804.43 | 804.43 | 21.0 | False | None | None | False | None | False | 16893.03 | 0 | | 3696177 | 135920 | None | code09 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.050 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete(32mm Dia) | m | 383.16 | 383.16 | 9.0 | False | None | None | False | None | False | 3448.44 | 0 | | 3696178 | 135920 | None | code10 | The Non Return Valve (NRV) assembly complete with rubber ‘O’ ring. | Each | 669.5 | 669.5 | 3.0 | False | None | None | False | None | False | 2008.5 | 0 | | 3696179 | 135920 | None | code11 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 91.67 | 91.67 | 49.099 | False | None | None | False | None | False | 4500.90533 | 0 | | 3696180 | 135920 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8466.6 | 8466.6 | 0.787 | False | None | None | False | None | False | 6663.2142 | 0 | | 3696181 | 135920 | None | code13 | Providing & Fixing on terrace on polythene water storage tank marked with cover & suitable locking arrangements (pwd sr 2021-22 1st addedam vol 2 sl/no 12.1 i.no 13.34 | Ltr | 9.27 | 9.27 | 3000.0 | False | None | None | False | None | False | 27810.0 | 0 | | 3696182 | 135920 | None | code14 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 116.39 | 116.39 | 750.0 | False | None | None | False | None | False | 87292.5 | 0 | | 3696183 | 135920 | None | code15 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm
(+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches
during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using
self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 585.04 | 585.04 | 216.0 | False | None | None | False | None | False | 126368.64 | 0 | | 3696184 | 135920 | None | code16 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading
and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned
are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant
necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of
Each components,For 500 LPH FRP : Skid Type | Each | 336810.0 | 336810.0 | 3.0 | False | None | None | False | None | False | 1010430.0 | 0 |
|