3698635 | 136121 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 95.0 | False | None | None | False | None | False | 24139.5 | 0 |
3698636 | 136121 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 20.09 | False | None | None | False | None | False | 119479.248 | 0 |
3698637 | 136121 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 41.91 | False | None | None | False | None | False | 246914.8605 | 0 |
3698638 | 136121 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 94.37 | False | None | None | False | None | False | 26357.541 | 0 |
3698639 | 136121 | None | code05 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For foundation | Cum | 6639.15 | 6639.15 | 79.02 | False | None | None | False | None | False | 524625.633 | 0 |
3698640 | 136121 | None | code06 | For footing 8 for Concrete qty rate | Cum | 531.13 | 531.13 | 11.09 | False | None | None | False | None | False | 5890.2317 | 0 |
3698641 | 136121 | None | code07 | For Cloumn (70 for Concrete qty rate | Cum | 4647.4 | 4647.4 | 13.43 | False | None | None | False | None | False | 62414.582 | 0 |
3698642 | 136121 | None | code08 | For Plinth Beam 50 Concrete qty rate | Cum | 3319.57 | 3319.57 | 10.28 | False | None | None | False | None | False | 34125.1796 | 0 |
3698643 | 136121 | None | code09 | For lintel and roof beams 60for Concrete qty rate | Cum | 3983.49 | 3983.49 | 11.98 | False | None | None | False | None | False | 47722.2102 | 0 |
3698644 | 136121 | None | code10 | For chejja 45for Concrete qty rate | Cum | 2987.61 | 2987.61 | 5.25 | False | None | None | False | None | False | 15684.9525 | 0 |
3698645 | 136121 | None | code11 | For roof slab 50 for Concrete qty rate | Cum | 3319.57 | 3319.57 | 26.99 | False | None | None | False | None | False | 89595.1943 | 0 |
3698646 | 136121 | None | code12 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. It No. 2.11 H P.No. 18 C.S.R 2023-24 P.No. 19 / I.No. 2.11 a (Volume-I) | t | 93929.85 | 93929.85 | 5.92 | False | None | None | False | None | False | 556064.712 | 0 |
3698647 | 136121 | None | code13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge ofwork | Cum | 8367.45 | 8367.45 | 58.22 | False | None | None | False | None | False | 487152.939 | 0 |
3698648 | 136121 | None | code14 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In charge including cost of materials, labour, usage charges of machinery complete as per specifications | Kgs | 120.75 | 120.75 | 14.4 | False | None | None | False | None | False | 1738.8 | 0 |
3698649 | 136121 | None | code15 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specification | Sqm | 1066.8 | 1066.8 | 14.4 | False | None | None | False | None | False | 15361.92 | 0 |
3698650 | 136121 | None | code16 | Providing and fixing in position fully glazed shutters for ventilators side hung or central pivoted with Mathi/Nandi wood stiles and rails of 30mm thick 50mm wide and central divider of 30mm. wide, 3mm thick reeded glass fixed with wooden beading of size 10mm wide flushed to the thickness of the frame including cost of materials, labour charges, usage charges complete as per specifications.excluding cost of fixtures | Sqm | 6904.8 | 6904.8 | 8.1 | False | None | None | False | None | False | 55928.88 | 0 |
3698651 | 136121 | None | code17 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as perdirections of Engineer-in-charge | Sqm | 267.75 | 267.75 | 483.16 | False | None | None | False | None | False | 129366.09 | 0 |
3698652 | 136121 | None | code18 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of aterials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 371.7 | 371.7 | 249.72 | False | None | None | False | None | False | 92820.924 | 0 |
3698653 | 136121 | None | code19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 124.0 | False | None | None | False | None | False | 149079.0 | 0 |
3698654 | 136121 | None | code20 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1161.3 | 1161.3 | 13.2 | False | None | None | False | None | False | 15329.16 | 0 |
3698655 | 136121 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as perspecifications and as per directions of Engineer in charge | Sqm | 105.0 | 105.0 | 349.44 | False | None | None | False | None | False | 36691.2 | 0 |
3698656 | 136121 | None | code22 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr per 10 sqm over and including priming coat of exterior primer applied @ 2.20 kgper 10 per with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 182.7 | 182.7 | 732.88 | False | None | None | False | None | False | 133897.176 | 0 |
3698657 | 136121 | None | code23 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charg | Kgs | 593.25 | 593.25 | 598.2 | False | None | None | False | None | False | 354882.15 | 0 |
3698658 | 136121 | None | code24 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 2627.1 | 2627.1 | 89.6 | False | None | None | False | None | False | 235388.16 | 0 |
3698659 | 136121 | None | code25 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 1521.45 | 1521.45 | 89.6 | False | None | None | False | None | False | 136321.92 | 0 |
3698660 | 136121 | None | code26 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification | Sqm | 978.6 | 978.6 | 89.6 | False | None | None | False | None | False | 87682.56 | 0 |
3698661 | 136121 | None | code27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 143.85 | 143.85 | 89.6 | False | None | None | False | None | False | 12888.96 | 0 |
3698662 | 136121 | None | code28 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 175.35 | 175.35 | 89.6 | False | None | None | False | None | False | 15711.36 | 0 |
3698663 | 136121 | None | code29 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications | Sqm | 1622.25 | 1622.25 | 89.6 | False | None | None | False | None | False | 145353.6 | 0 |
3698664 | 136121 | None | code30 | Providing & fixing of 3 track 2panel sliding windows made out of multi chambered complete specifications as per boq enclosed separately | Sqm | 7070.7 | 7070.7 | 4.2 | False | None | None | False | None | False | 29696.94 | 0 |
3698665 | 136121 | None | code31 | Using 2 single core wires for a single phase and 4 single core wires for 3 phase supplying and stringing PVC insulated and PVC sheathed 650/1100 V class aluminum conductor of size supported by 3.15mm (10 SWG GImessenger wire with two break insulators, one at each end of the span with suspenders at intervals of 0.75 m Each suspender shall be of porcelain reel insulator of suitable core through which insulated wire passes (single core or twin core as the case may be) and this reel insulator shall fixed to the messenger wire using 2mm (No. 14 SWG) GI wire suitably bent and twisted. Separate reel insulator shall be provided for each wire, the messanger wire shal be ded -ended on the clamp provided to the departmental pole | Mtr | 47.25 | 47.25 | 30.0 | False | None | None | False | None | False | 1417.5 | 0 |
3698666 | 136121 | None | code32 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same on the wall using tapered inverted wooden plugs screws | Nos | 139.57 | 139.57 | 10.0 | False | None | None | False | None | False | 1395.7 | 0 |
3698667 | 136121 | None | code33 | Supplying and fixing 32 Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 59 Hz AC Supply & completely wired on existing box | Nos | 697.89 | 697.89 | 10.0 | False | None | None | False | None | False | 6978.9 | 0 |
3698668 | 136121 | None | code34 | Supplying & fixing of Porcelain fuse channels with cut out on existing wooden /panel using necessary nuts, bolts and washers etc., complete | Nos | 110.77 | 110.77 | 20.0 | False | None | None | False | None | False | 2215.4 | 0 |
3698669 | 136121 | None | code35 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required | Nos | 564.95 | 564.95 | 10.0 | False | None | None | False | None | False | 5649.5 | 0 |
3698670 | 136121 | None | code36 | Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduitcasing caping using copper PVC insulated multi strand 2 1.5 Sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round blockcomplete for each outlet | Mtr | 797.58 | 797.58 | 60.0 | False | None | None | False | None | False | 47854.8 | 0 |
3698671 | 136121 | None | code37 | Supplying and Fixing of PVC casing and caping on wall or ceiling using necessary materials like bends, screws at an interval of 300 mm etc as required. c) 32 mm | Mtr | 49.84 | 49.84 | 80.0 | False | None | None | False | None | False | 3987.2 | 0 |
3698672 | 136121 | None | code38 | Supplying and fiixing/replacing of 6 /16/32 Amps electrical accessories on existing switch board [ P.No-50/ Sl No-34 ] a) 6 Amps SP Switch | Nos | 34.33 | 34.33 | 30.0 | False | None | None | False | None | False | 1029.9 | 0 |
3698673 | 136121 | None | code39 | c) 6 Amps 3 Way 5 Pin Socket | Nos | 45.41 | 45.41 | 30.0 | False | None | None | False | None | False | 1362.3 | 0 |
3698674 | 136121 | None | code40 | 6 Amps Bakelite Ceiling Rose | Nos | 37.66 | 37.66 | 20.0 | False | None | None | False | None | False | 753.2 | 0 |
3698675 | 136121 | None | code41 | 6 Amps Lamps Holder | Nos | 42.09 | 42.09 | 30.0 | False | None | None | False | None | False | 1262.7 | 0 |
3698676 | 136121 | None | code42 | Supplying Patti Type Fluorescent Tube Light Fitting of 4' Suitable for 28 Watts Fluorescent Tube Fitting, made out of M.S Sheet and Stove enameled with HF Electronic Ballast, Locking Type Brass Contact holders mounted on double fold type sheets base fully wired for use on 230 Volts AC Supply Including T-5 Lamp | Nos | 702.45 | 702.45 | 20.0 | False | None | None | False | None | False | 14049.0 | 0 |
3698677 | 136121 | None | code43 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical pecifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 11.2 | False | None | None | False | None | False | 2845.92 | 0 |
3698678 | 136121 | None | code44 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregate | Cum | 5947.2 | 5947.2 | 1.4 | False | None | None | False | None | False | 8326.08 | 0 |
3698679 | 136121 | None | code45 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as perrelevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, abour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Page - 16 Karnataka Public Works Department Volume-1 KPWD VOL-1 ItemNo. escription of Item Unit Rate 2.3.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6568.8 | 6568.8 | 3.56 | False | None | None | False | None | False | 23384.928 | 0 |
3698680 | 136121 | None | code46 | Percentage Additionalities for FormworkCentering Scaffolding As per recommendations of Technical working group ates for formwork shall be added on percentage basis to the finished concrete item rate as per table below Foundation Sub structure | Cum | 331.96 | 331.96 | 3.77 | False | None | None | False | None | False | 1251.4892 | 0 |
3698681 | 136121 | None | code47 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. It No. 2.11 H | t | 93929.85 | 93929.85 | 0.15 | False | None | None | False | None | False | 14089.4775 | 0 |
3698682 | 136121 | None | code48 | Construction of Sub grade and Earthen Shoulders Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 1.8 | False | None | None | False | None | False | 931.77 | 0 |
3698683 | 136121 | None | code49 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & up to depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labour, tools, usage of machinery & other appurtenancesrequired to complete the work | Cum | 99.75 | 99.75 | 18.0 | False | None | None | False | None | False | 1795.5 | 0 |
3698684 | 136121 | None | code50 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | Cum | 89.25 | 89.25 | 18.0 | False | None | None | False | None | False | 1606.5 | 0 |
3698685 | 136121 | None | code51 | Compacting original ground supporting embankment Loosening, levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction | Cum | 110.25 | 110.25 | 13.5 | False | None | None | False | None | False | 1488.375 | 0 |
3698686 | 136121 | None | code52 | Construction of Sub grade and Earthen Shoulders Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 13.5 | False | None | None | False | None | False | 6988.275 | 0 |
3698687 | 136121 | None | code53 | Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.PWD | Cum | 2686.95 | 2686.95 | 14.4 | False | None | None | False | None | False | 38692.08 | 0 |
3698688 | 136121 | None | code54 | Cobble Stone for Shoulders Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications2 | Sqm | 840.0 | 840.0 | 180.0 | False | None | None | False | None | False | 151200.0 | 0 |