1722841501000 | 1 | None | None | Buildings | Construction of samudya bhavan in survey no 130 devaraj nagara at ward no 54 old ward no 41 | 1266019.57 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3690013 | 135503 | None | code001 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Vol 02 Pg No 163, Item No-19.3 | Cum | 1950.9 | 1950.9 | 3.89 | False | None | None | False | None | False | 7589.001 | 0 | 3690014 | 135503 | None | code002 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol 02 Pg No 42, Item No-8.6.1 | Sqm | 287.7 | 287.7 | 231.43 | False | None | None | False | None | False | 66582.411 | 0 | 3690015 | 135503 | None | code003 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Vol 01 Pg No 15, Item No-2.1.3 | Cum | 5831.7 | 5831.7 | 1.84 | False | None | None | False | None | False | 10730.328 | 0 | 3690016 | 135503 | None | code004 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Vol-1 Pg No 17 Item No. 2.5.1 | Cum | 6491.1 | 6491.1 | 15.74 | False | None | None | False | None | False | 102169.914 | 0 | 3690017 | 135503 | None | code005 | Additionalities for Formwork,centering & Scaffolding : Columns (70%) Appendix -1 SL NO.8 Vol-1 Pg No 115 | Cum | 4543.77 | 4543.77 | 1.86 | False | None | None | False | None | False | 8451.4122 | 0 | 3690018 | 135503 | None | code006 | Additionalities for Formwork,centering & Scaffolding : Beams& lintels of Building (60%) Appendix -1 SL NO.12 Vol-1 Pg No 115 | Cum | 3894.66 | 3894.66 | 2.94 | False | None | None | False | None | False | 11450.3004 | 0 | 3690019 | 135503 | None | code007 | Additionalities for Formwork,centering & Scaffolding : Roof slab of building (50%) Appendix -1 SL NO.13,14 Vol-1 Pg No 115 | Cum | 3245.55 | 3245.55 | 9.52 | False | None | None | False | None | False | 30897.636 | 0 | 3690020 | 135503 | None | code008 | Additionalities for Formwork,centering & Scaffolding : chejjas, canopy & other Architectural projections of minor sections (45%) Appendix -1 SL NO.20 Vol-1 Pg No 115 | Cum | 2921.0 | 2921.0 | 1.42 | False | None | None | False | None | False | 4147.82 | 0 | 3690021 | 135503 | None | code009 | Supplying, Fitting and Placing TMT Fe 550 Reinforcement in Foundation / Substructure /
Superstructure complete as per Drawing and Technical Specifications.Vol 03, Pg No-71 Item No-9.3 | Tonne | 84311.85 | 84311.85 | 1.51 | False | None | None | False | None | False | 127310.8935 | 0 | 3690022 | 135503 | None | code010 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol 02 Pg No 13, Item No-6.3 | Cum | 8022.0 | 8022.0 | 87.06 | False | None | None | False | None | False | 698395.32 | 0 | 3690023 | 135503 | None | code011 | Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol 02 Pg No 46, Item No-8.30 | Sqm | 142.8 | 142.8 | 231.43 | False | None | None | False | None | False | 33048.204 | 0 | 3690024 | 135503 | None | code012 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Vol 02 Pg No 50, Item No-8.51 | Sqm | 87.15 | 87.15 | 287.04 | False | None | None | False | None | False | 25015.536 | 0 | 3690025 | 135503 | None | code013 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol 02 Pg No 48 Item No-8.39 | Sqm | 99.75 | 99.75 | 231.43 | False | None | None | False | None | False | 23085.1425 | 0 | 3690026 | 135503 | None | code014 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. Vol 02 Pg No 88 Item No-11.37.2 | Sqm | 961.8 | 961.8 | 8.28 | False | None | None | False | None | False | 7963.704 | 0 | 3690027 | 135503 | None | code015 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ anglesections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer- in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications. Vol 02 Pg No 89, Item No-11.39 | Kg | 574.35 | 574.35 | 61.27 | False | None | None | False | None | False | 35190.4245 | 0 | 3690028 | 135503 | None | code016 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Vol 02 Pg No105, Item No-12.54 | m | 498.75 | 498.75 | 1.89 | False | None | None | False | None | False | 942.6375 | 0 | 3690029 | 135503 | None | code017 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.Vol 02 Pg No 106, Item No-12.55.1 | Sqm | 3993.15 | 3993.15 | 0.6 | False | None | None | False | None | False | 2395.89 | 0 | 3690030 | 135503 | None | code018 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Vol 02 Pg No 85, Item No-11.34B | Kg | 164.85 | 164.85 | 68.04 | False | None | None | False | None | False | 11216.394 | 0 | 3690031 | 135503 | None | code019 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm Vol 02 Pg No 62, Item No-9.22.2 | Sqm | 1324.05 | 1324.05 | 44.89 | False | None | None | False | None | False | 59436.6045 | 0 |
|