createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721628682313
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd254200.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-08-2024 17:30:00
tenderQueryClose13-08-2024 16:30:00
technicalBidOpen23-08-2024 10:30:00
publishedDate07-08-2024 11:40:43
publishedByPostDUDC_EE_HAV
publishedByUserKPE12612 - Mattikatti S S
bidValidityPeriod90
noOfCalls1
preBidMeetingDate30-07-2024 16:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSUBHAS G KAMBALI
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448223850
tenderSupplierListNone
tenderSchedule
createdTs1721628682360
version13
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT18550
titleConstruction of new office building in rs no87 and 88 in TP Rattihalli under AMRUT Nagarothan Phase 4
descriptionConstruction of new office building in rs no87 and 88 in TP Rattihalli under AMRUT Nagarothan Phase 4 (CALL-3 Tender of Tender No DMA/2023-24/BD/WORK-INDENT146892)
categoryWORKS
categoryTextWorks
ecv19991669.36
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2192
locationNameDMA District Urban Development Cell Haveri
provisionalAmount20000000.0
groupOverheadTotal3049576.69
fileNumberDMA/2024-25/ANH-4/RTH/BD/WORK-INDENT146892/CALL-3
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17216286820001NoneNoneBuildingsconstruction of new office building in rs no87 and 88 for TP Rattihalli16942092.67
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3574669129934Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work..(Page No.05. Iitem no.1.12 of Vol-1- -KPWD 2023-2024)Cum97.8597.85195.299FalseNoneNoneFalseNoneFalse19110.007150
3574670129934Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils Depth upto 3 m(Page No.08. Iitem no.1.14.1 of Vol-1- -KPWD 2023-2024)Cum105.06105.06334.4332FalseNoneNoneFalseNoneFalse35135.5519920
3574671129934Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In ordinary/soft rock without blasting upto 1.5 m depth (Page No.08. Iitem no.1.15.1 of Vol-1- -KPWD 2023-2024)Cum373.89373.8931.4325FalseNoneNoneFalseNoneFalse11752.2974250
3574672129934Nonecode04Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page No.07. Iitem no.1.9 of Vol-1- -KPWD 2023-2024)Cum273.98273.98314.325FalseNoneNoneFalseNoneFalse86118.76350
3574673129934Nonecode05Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(Page No.05. Iitem no.4.1 of Vol-2- -KPWD 2023-2024)Sqm121.54121.54682.0FalseNoneNoneFalseNoneFalse82890.280
3574674129934Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.1.3 of Vol-1- -KPWD 2023-2024)Cum6168.676168.67163.996FalseNoneNoneFalseNoneFalse1011637.205320
3574675129934Nonecode07Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) The work includes cost of all materials, labour charges etc all leads and lifts, HOM machineries & fuel and all other incidental works curing etc., required to complete the work as per all relevant specifications and as per the directions of Engineer in charge of work (Page No.09. Iitem no.5.4 of Vol-2- -KPWD 2023-2024)Cum6580.676580.6760.5034FalseNoneNoneFalseNoneFalse398152.9092780
3574676129934Nonecode08Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.2.3 of Vol-1- -KPWD 2023-2024)Cum6526.086526.08157.5929FalseNoneNoneFalseNoneFalse1028463.8728320
3574677129934Nonecode09Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. (For Footing at 8 percent)Cum522.08522.08157.5929FalseNoneNoneFalseNoneFalse82276.1012320
3574678129934Nonecode10Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.2.3 of Vol-1- -KPWD 2023-2024)Cum6526.086526.086.5625FalseNoneNoneFalseNoneFalse42827.40
3574679129934Nonecode11Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. (for Pedastals at 5 percent)Cum326.3326.36.5625FalseNoneNoneFalseNoneFalse2141.343750
3574680129934Nonecode12Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.3.2 of Vol-1- -KPWD 2023-2024)Cum6674.46674.432.4096FalseNoneNoneFalseNoneFalse216314.634240
3574681129934Nonecode13Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. (for Plinth Beam at at 50 percent)Cum3337.23337.232.4096FalseNoneNoneFalseNoneFalse108157.317120
3574682129934Nonecode14Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.2.3 of Vol-1- -KPWD 2023-2024)Cum6526.086526.086.5625FalseNoneNoneFalseNoneFalse42827.40
3574683129934Nonecode15Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. (for columns below plinth at 70 percent)Cum4568.254568.256.5625FalseNoneNoneFalseNoneFalse29979.1406250
3574684129934Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1- -KPWD 2023-2024)Cum7048.297048.2924.57FalseNoneNoneFalseNoneFalse173176.48530
3574685129934Nonecode17Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. for columns above plinth at 70 percentCum4933.84933.824.57FalseNoneNoneFalseNoneFalse121223.4660
3574686129934Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1- -KPWD 2023-2024)Cum7048.297048.2946.9544FalseNoneNoneFalseNoneFalse330948.2279760
3574687129934Nonecode19Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. for ground floor lintel at 60 percentCum4228.974228.9746.9544FalseNoneNoneFalseNoneFalse198568.7489680
3574688129934Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1- -KPWD 2023-2024)Cum7048.297048.29101.3391FalseNoneNoneFalseNoneFalse714267.3651390
3574689129934Nonecode21Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. for ground floor slab at 50 percentCum3524.153524.15101.3391FalseNoneNoneFalseNoneFalse357134.1892650
3574690129934Nonecode22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1- -KPWD 2023-2024)Cum7048.297048.296.8557FalseNoneNoneFalseNoneFalse48320.9617530
3574691129934Nonecode23Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. (for ground floor Chejja at 45 percent)Cum3171.733171.736.8557FalseNoneNoneFalseNoneFalse21744.4293610
3574692129934Nonecode24Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1- -KPWD 2023-2024)Cum7118.777118.775.3617FalseNoneNoneFalseNoneFalse38168.7091090
3574693129934Nonecode25Providing and removing centering, shuttering, strutting, propping etc for all length and widths The work includes cost of all materials, labour charges, all leads and lifts all other incidental works required to complete the work as per relevant specifications and directions of Engineer in charge of work. (Formwork-1st Floor -Stairs-For Centering & Shuttering 45 percent)Cum3203.453203.455.3617FalseNoneNoneFalseNoneFalse17175.9378650
3574694129934Nonecode26Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification-Buildings-(PWD SR 2023-24 Vol:1 P.NO.18 I.No.2.11A)t92140.7192140.7140.4255FalseNoneNoneFalseNoneFalse3724834.2721050
3574695129934Nonecode27Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page No.17. Iitem no.6.32 of Vol-2- -KPWD 2023-2024)Sqm1349.31349.3546.2894FalseNoneNoneFalseNoneFalse737108.287420
3574696129934Nonecode28Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page No.17. Iitem no.6.33 of Vol-2- -KPWD 2023-2024)Sqm1267.931267.9325.2FalseNoneNoneFalseNoneFalse31951.8360
3574697129934Nonecode29Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off orners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per pecifications and as per directions of Engineer-in-charge(In side Plastering)(Page No.41. Iitem no.8.4.1 of Vol-2- -KPWD 2023-2024)Sqm332.69332.691213.8838FalseNoneNoneFalseNoneFalse403847.0014220
3574698129934Nonecode30Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Page No.41. Iitem no.8.2.1 of Vol-2- -KPWD 2023-2024)Sqm303.85303.85363.49FalseNoneNoneFalseNoneFalse110446.43650
3574699129934Nonecode31Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Page No.63. Iitem no.9.24 of Vol-2- -KPWD 2023-2024)Sqm2937.562937.56592.886FalseNoneNoneFalseNoneFalse1741638.198160
3574700129934Nonecode32In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile Colour glazed tile 30x45 cms 6mm thick with border of size 30 x 10 cms(Page No.60. Iitem no.9.7.2 of Vol-2- -KPWD 2023-2024)Sqm1297.81297.81185.77FalseNoneNoneFalseNoneFalse1538892.3060
3574701129934Nonecode33Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(Page No.64. Iitem no.9.30 of Vol-2- -KPWD 2023-2024)Sqm5487.845487.8419.711FalseNoneNoneFalseNoneFalse108170.814240
3574702129934Nonecode34Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.(Page No.60. Iitem no.9.9 of Vol-2- -KPWD 2023-2024)Sqm1108.281108.2834.944FalseNoneNoneFalseNoneFalse38727.736320
3574703129934Nonecode35Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.46. Iitem no.8.29 of Vol-2- -KPWD2023-2024)Sqm291.49291.49363.49FalseNoneNoneFalseNoneFalse105953.70010
3574704129934Nonecode36Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Page No.50. Iitem no.8.51 of Vol-2- -KPWD 2023-2024)Sqm103.0103.01213.883FalseNoneNoneFalseNoneFalse125029.9490
3574705129934Nonecode37Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.48. Iitem no.8.39 of Vol-2- -KPWD 2023-2024)Sqm130.81130.811213.883FalseNoneNoneFalseNoneFalse158788.035230
3574706129934Nonecode38Providing Teak wood OR Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications(Page No.99. Iitem no.12.11 of Vol-2- -KPWD 2023-2024)Cum142216.22142216.220.5205FalseNoneNoneFalseNoneFalse74023.542510
3574707129934Nonecode39Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick Both side teak(Page No.105. Iitem no.12.57.1 of Vol-2- -KPWD 2023-2024)Sqm4164.294164.2918.375FalseNoneNoneFalseNoneFalse76518.828750
3574708129934Nonecode40Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :100x70x4 mm (ordinary type)(Page No.107. Iitem no.12.75.4 of Vol-2- -KPWD 2023-2024)Nos144.2144.227.0FalseNoneNoneFalseNoneFalse3893.40
3574709129934Nonecode41Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm(Page No.107. Iitem no.12.76.2 of Vol-2- -KPWD2023-2024)Each360.5360.527.0FalseNoneNoneFalseNoneFalse9733.50
3574710129934Nonecode42Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10mm(Page No.107. Iitem no.12.76.4 of Vol-2- -KPWD 2023-2024)Each202.91202.9127.0FalseNoneNoneFalseNoneFalse5478.570
3574711129934Nonecode43Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.(Page No.105. Iitem no.12.61 of Vol-2- -KPWD 2023-2024)Nos1019.71019.79.0FalseNoneNoneFalseNoneFalse9177.30
3574712129934Nonecode44Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(Page No.105. Iitem no.12.60 of Vol-2- -KPWD 2023-2024)Nos1083.561083.569.0FalseNoneNoneFalseNoneFalse9752.040
3574713129934Nonecode45Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete(Page No.105. Iitem no.12.62 of Vol-2- -KPWD2023-2024)Nos244.11244.119.0FalseNoneNoneFalseNoneFalse2196.990
3574714129934Nonecode46Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(Page No.105. Iitem no.12.59 of Vol-2- -KPWD 2023-2024)Nos1147.421147.429.0FalseNoneNoneFalseNoneFalse10326.780
3574715129934Nonecode47Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.(Page No.105. Iitem no.12.58 of Vol-2- -KPWD 2023-2024)Nos123.6123.69.0FalseNoneNoneFalseNoneFalse1112.40
3574716129934Nonecode48Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (Page No.104. Iitem no.12.51 of Vol-2- -KPWD 2023-2024)Nos1046.481046.481.0FalseNoneNoneFalseNoneFalse1046.480
3574717129934Nonecode49Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.(Page No.86. Iitem no.11.34B of Vol-2- -KPWD 2023-2024)Kg188.49188.49498.96FalseNoneNoneFalseNoneFalse94048.97040
3574718129934Nonecode50Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(Page No.110. Iitem no.12.90 of Vol-2- -KPWD 2023-2024)Sqm6936.026936.0227.0FalseNoneNoneFalseNoneFalse187272.540
3574719129934Nonecode51Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(Page No.109. Iitem no.12.85 of Vol-2- -KPWD2023-2024)Sqm5890.575890.570.72FalseNoneNoneFalseNoneFalse4241.21040
3574720129934Nonecode52Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.47. Iitem no.8.34.2 of Vol-2- -KPWD 2023-2024)Sqm59.7459.7418.375FalseNoneNoneFalseNoneFalse1097.72250
3574721129934Nonecode53Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.46. Iitem no.8.33.2 of Vol-2- -KPWD2023-2024)Sqm142.14142.1418.375FalseNoneNoneFalseNoneFalse2611.82250
3574722129934Nonecode54Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.48. Iitem no.8.37 of Vol-2- -KPWD 2023-2024)Sqm134.93134.9327.72FalseNoneNoneFalseNoneFalse3740.25960
3574723129934Nonecode55Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as(Page No.85. Iitem no.11.28 of Vol-2- -KPWD 2023-2024)Kg581.95581.95180.0FalseNoneNoneFalseNoneFalse104751.00
3574724129934Nonecode56Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge(Page No.84. Iitem no.11.26.1 of Vol-2- -KPWD 2023-2024)Kg142.14142.14524.475FalseNoneNoneFalseNoneFalse74548.87650
3574725129934Nonecode57Transportation and Disposal of Excavated Earth, including all types of debris including dressing, leveling and loading & unloading mechanical or manual means, all lifts, all leads as per relevant specifications and directions of engineer in charge of work to a lead of all distancesLoading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 5.5 m3)(Page No.5. Iitem no.1.1 of Vol-3- -KPWD 2023-2024)Cum139.05139.05561.1657FalseNoneNoneFalseNoneFalse78030.0905850
3574726129934Nonecode58Open Conduit SystemSupplying heavy gauge PVC conduit pipe19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an interval of 700mm using NF screws( -KPWD - Elec Vol-VI, 2023-2024: Page No.02, Item No. 1.1.1)m71.0771.07600.0FalseNoneNoneFalseNoneFalse42642.00
3574727129934Nonecode59Open Conduit System Supplying heavy gauge PVC conduit pipe25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an interval of 700mm using NF screws( -KPWD - Elec Vol-VI,2023-2024: Page No.02, Item No. 1.1.2)m83.4383.43600.0FalseNoneNoneFalseNoneFalse50058.00
3574728129934Nonecode60Supplying heavy gauge PVC Conduit Pipe .... dia .......mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary 19/20 mm dia 2 mm thick( -KPWD - Elec Vol-VI, 2023-2024: Page No.02, Item No. 1.3.1)m70.0470.04600.0FalseNoneNoneFalseNoneFalse42024.00
3574729129934Nonecode61Supplying heavy gauge PVC Conduit Pipe 25 mm dia 2mm mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary.( -KPWD - Elec Vol-VI, 2023-2024: Page No.02, Item No. 1.3.2)m81.3781.37400.0FalseNoneNoneFalseNoneFalse32548.00
3574730129934Nonecode62Concealed Conduit System Supplying heavy gauge PVC conduit pipe 32 mm dia.2.5 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., andrunning before concreting the slab. The conduit should be tiedto the reinforcement rods by using binding wires and unusedways of junction boxes and pipe ends should be coveredusing PVC end enclosures, run with 18SWG GI fish wire wherever necessary( -KPWD - Elec Vol-VI, 2023-2024: Page No.02, Item No. 1.2.3)m106.09106.09500.0FalseNoneNoneFalseNoneFalse53045.00
3574731129934Nonecode63Supplying heavy gauge PVC Conduit Pipe 32 dia 2.5 mm thick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary( -KPWD - Elec Vol-VI,2023-2024: Page No.02, Item No. 1.3.3)m101.97101.97450.0FalseNoneNoneFalseNoneFalse45886.50
3574732129934Nonecode64Supplying 250 A 4 x 30 x 10 mm Aluminium Strips rated 3 phase with neutral bus bar usingrequired capacity electrolytic aluminium strips covered withheat shrinkable coloured PVC sleeve, mounted onphenolic/FRP/DMC insulator which are mounted on powdercoated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination ofincoming and outgoing cables as per IS specification withnecessary bolts, nuts and washers etc., complete - 250 A 4 x 30 x 10 mm Aluminium Strips( -KPWD - Elec Vol-VI, 2023-2024: Page No.20, Item No. 5.40.2)m3538.053538.0560.0FalseNoneNoneFalseNoneFalse212283.00
3574733129934Nonecode65WIRES & CABLES Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Short point upto 3m from tapping point to out let via switch( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 2.1.1)Point293.55293.55400.0FalseNoneNoneFalseNoneFalse117420.00
3574734129934Nonecode66WIRES & CABLES Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch.( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 2.1.2)Point405.82405.82210.0FalseNoneNoneFalseNoneFalse85222.20
3574735129934Nonecode67WIRES & CABLES Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 2.1.3)Point587.1587.1175.0FalseNoneNoneFalseNoneFalse102742.50
3574736129934Nonecode68Supplying 6A flush type socket and 6Amps flush type SP switch either surface / flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. as per IS 1293 and IS 3654 A) 6 Amps 3/5 way( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.1.2)Each151.41151.41125.0FalseNoneNoneFalseNoneFalse18926.250
3574737129934Nonecode69Supplying and mounting 2 Nos of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required. IS 3854 ( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.2)Each175.1175.155.0FalseNoneNoneFalseNoneFalse9630.50
3574738129934Nonecode70Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.- 1 mm2 ( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 2.3.1)m19.5719.571400.0FalseNoneNoneFalseNoneFalse27398.00
3574739129934Nonecode71Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments- 2.5 mm2 ( -KPWD - Elec Vol-VI,2023-2024: Page No.05, Item No. 2.3.3)m43.2643.26300.0FalseNoneNoneFalseNoneFalse12978.00
3574740129934Nonecode72Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments- 4.00 mm2 ( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 2.3.4)m64.8964.893500.0FalseNoneNoneFalseNoneFalse227115.00
3574741129934Nonecode73Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments- 10.00 mm2 ( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 2.3.6)m172.01172.01300.0FalseNoneNoneFalseNoneFalse51603.00
3574742129934Nonecode74Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and withdouble ball bearing system.- 48" Sweep (1200 mm) Regular model ( -KPWD - Elec Vol-VI, 2023-2024: Page No.30, Item No. 6.3.1)Each3073.523073.5235.0FalseNoneNoneFalseNoneFalse107573.20
3574743129934Nonecode75Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to theexistingboard together with supplying and fixing 5 A. ceiling rose,necessary length of 23 / 0.0076 inch PVC insulated twintwisted copper wire and wiring( -KPWD - Elec Vol-VI, 2023-2024: Page No.57, Item No. 13.10)Nos176.13176.1330.0FalseNoneNoneFalseNoneFalse5283.90
3574744129934Nonecode76Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.- 6A Lamp Holder( -KPWD - Elec Vol-VI, 2023-2024: Page No.10, Item No. 3.14.6)Nos73.1373.1375.0FalseNoneNoneFalseNoneFalse5484.750
3574745129934Nonecode77pplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.- 6A Bakelite Ceiling Rose( -KPWD - Elec Vol-VI, 2023-2024: Page No.06, Item No. 3.14.5)Nos80.3480.3442.0FalseNoneNoneFalseNoneFalse3374.280
3574746129934Nonecode78Supplying of recess mounting non integrated type LED down light15-18W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceilingclA, LED of Power/COB with CCT 6500 degree K, CRI70%. efficacy 100 lumen per W, 120degree beam spread,life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosedwith anti glare opal diffuser which enhances the lightinglevel. LED's are driven by HF electronic driver integrated in aseparate control gear assembly., with PF 0.95, power lossshould 5% of lamp Wage, short circuit & open circuitprotection to be integrated in the circuit, THD less than 20%,Life as per LM 79. The operating input voltage should bebetween 130 to 275 V. BIS Approved and Tested byNABL/CPRI accredited laboratory with 2 years Warrantyagainst any manufacturing defect working under standard electrical condition.- 15-18W( -KPWD - Elec Vol-VI, 2023-2024: Page No.44, Item No.11.4.3)Each1721.131721.1340.0FalseNoneNoneFalseNoneFalse68845.20
3574747129934Nonecode79Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.- 15" Sweep (450 mm)( -KPWD - Elec Vol-VI, 2023-2024: Page No.30, Item No. 6.2.2)Each4579.384579.387.0FalseNoneNoneFalseNoneFalse32055.660
3574748129934Nonecode80Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to matchthe existing wall or brackets, with bolts and nuts and a 5 A,ceiling rose with sufficient length of 23 / 0.0076 inch PVCinsulated twin core wire of approved make with wire meshand wooden frame.( -KPWD - Elec Vol-VI, 2022-23: Page No.57, Item No. 13.13)Each728.21728.2117.0FalseNoneNoneFalseNoneFalse12379.570
3574749129934Nonecode81Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 63 Amps( -KPWD - Elec Vol-VI,2023-2024: Page No.14, Item No. 5.7.3)Each413.03413.0350.0FalseNoneNoneFalseNoneFalse20651.50
3574750129934Nonecode82Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 100 Amps( -KPWD - Elec Vol-VI, 2023-2024: Page No.14, Item No. 5.7.4)Each711.73711.7340.0FalseNoneNoneFalseNoneFalse28469.20
3574751129934Nonecode83Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6 - 32 Amps DP( -KPWD - Elec Vol-VI, 2023-2024: Page No.17, Item No. 5.18.4)Each761.17761.1740.0FalseNoneNoneFalseNoneFalse30446.80
3574752129934Nonecode84Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50 - 63 Amps DP( -KPWD - Elec Vol-VI, 2023-2024: Page No.17, Item No. 5.18.6)Each1135.061135.0640.0FalseNoneNoneFalseNoneFalse45402.40
3574753129934Nonecode85Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6 - 32 Amps TPN( -KPWD - Elec Vol-VI, 2023-2024: Page No.17, Item No. 5.18.7)Each1768.511768.5115.0FalseNoneNoneFalseNoneFalse26527.650
3574754129934Nonecode86Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50 - 63 Amps TPN( -KPWD - Elec Vol-VI, 2023-2024: Page No.18, Item No. 5.18.9)Each3180.643180.6430.0FalseNoneNoneFalseNoneFalse95419.20
3574755129934Nonecode87Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door -16 Way SP & N ( -KPWD - Elec Vol-VI, 2023-2024: Page No.18, Item No. 5.19.5)Each3019.963019.9612.0FalseNoneNoneFalseNoneFalse36239.520
3574756129934Nonecode88Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure.II - Double Door-12 Way SP & N( -KPWD - Elec Vol-VI, 2023-2024: Page No.18, Item No. 5.19.9)Each2398.872398.877.0FalseNoneNoneFalseNoneFalse16792.090
3574757129934Nonecode89Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.-16A-25A 2 pole (KPWD - Elec Vol-VI, 2023-2024: Page No.18, Item No. 5.20.1)Each4405.314405.312.0FalseNoneNoneFalseNoneFalse8810.620
3574758129934Nonecode90Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.-32-40A 2 pole(KPWD - Elec Vol-VI, 2023-2024: Page No.18, Item No. 5.20.4)Each4695.774695.772.0FalseNoneNoneFalseNoneFalse9391.540
3574759129934Nonecode91Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.-32-40A 4 pole(KPWD - Elec Vol-VI, 2023-2024: Page No.18, Item No. 5.20.8)Each5301.415301.414.0FalseNoneNoneFalseNoneFalse21205.640
3574760129934Nonecode92Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.-63 A 4 pole(KPWD - Elec Vol-VI, 2023-2024: Page No.18, Item No. 5.20.10)Each5711.355711.353.0FalseNoneNoneFalseNoneFalse17134.050
3574761129934Nonecode932 Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote-Ding Dong Bell(KPWD - Elec Vol-VI, 2023-2024: Page No.48, Item No. 12.2.1)Each253.38253.385.0FalseNoneNoneFalseNoneFalse1266.90
3574762129934Nonecode94Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall1-3 Way( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.4.2)Each163.77163.7720.0FalseNoneNoneFalseNoneFalse3275.40
3574763129934Nonecode95Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall4-5 Way( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.4.3)Each182.31182.3120.0FalseNoneNoneFalseNoneFalse3646.20
3574764129934Nonecode96Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall6 Way( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 3.4.4)Each226.6226.620.0FalseNoneNoneFalseNoneFalse4532.00
3574765129934Nonecode97Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall8 Way( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.4.5)Each268.83268.8320.0FalseNoneNoneFalseNoneFalse5376.60
3574766129934Nonecode98Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall10-12 Way ( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.4.6)Each328.57328.5720.0FalseNoneNoneFalseNoneFalse6571.40
3574767129934Nonecode99Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 Way( -KPWD - Elec Vol-VI,2023-2024: Page No.08, Item No. 3.4.8)Each417.15417.1520.0FalseNoneNoneFalseNoneFalse8343.00
3574768129934Nonecode100Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box1 to 3 Module( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.5.2)Each165.83165.8320.0FalseNoneNoneFalseNoneFalse3316.60
3574769129934Nonecode101Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box4 Module( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.5.3)Each180.25180.2520.0FalseNoneNoneFalseNoneFalse3605.00
3574770129934Nonecode102Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box6 Module( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.5.4)Each241.02241.0220.0FalseNoneNoneFalseNoneFalse4820.40
3574771129934Nonecode103Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box8 Module( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.5.5)Each292.52292.5220.0FalseNoneNoneFalseNoneFalse5850.40
3574772129934Nonecode104Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box10-12 Module( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.5.6)Each354.32354.3220.0FalseNoneNoneFalseNoneFalse7086.40
3574773129934Nonecode105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 18 Module( -KPWD - Elec Vol-VI, 2023-2024: Page No.08, Item No. 3.5.8)Each470.71470.7120.0FalseNoneNoneFalseNoneFalse9414.20
3574774129934Nonecode106Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch ( -KPWD - Elec Vol-VI, 2023-2024: Page No.09, Item No. 3.6.1)Each105.06105.0622.0FalseNoneNoneFalseNoneFalse2311.320
3574775129934Nonecode107Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch( -KPWD - Elec Vol-VI, 2023-2024: Page No.09, Item No. 3.6.2)Each170.98170.9820.0FalseNoneNoneFalseNoneFalse3419.60
3574776129934Nonecode108Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket( -KPWD - Elec Vol-VI, 2023-2024: Page No.09, Item No. 3.6.3)Each176.13176.139.0FalseNoneNoneFalseNoneFalse1585.170
3574777129934Nonecode109Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch( -KPWD - Elec Vol-VI, 2023-2024: Page No.09, Item No. 3.6.7)Each185.4185.422.0FalseNoneNoneFalseNoneFalse4078.80
3574778129934Nonecode110Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket( -KPWD - Elec Vol-VI,2023-2024 Page No.09, Item No. 3.6.10)Each243.08243.0823.0FalseNoneNoneFalseNoneFalse5590.840
3574779129934Nonecode111Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch( -KPWD - Elec Vol-VI, 2023-2024: Page No.09, Item No. 3.6.9)Each335.78335.7823.0FalseNoneNoneFalseNoneFalse7722.940
3574780129934Nonecode112Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push( -KPWD - Elec Vol-VI, 2023-2024: Page No.09, Item No. 3.6.8)Each182.31182.315.0FalseNoneNoneFalseNoneFalse911.550
3574781129934Nonecode113Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 2' - 9/10 W( -KPWD - Elec Vol-VI, 2023-2024: Page No.43, Item No. 11.3.1)Each567.53567.5322.0FalseNoneNoneFalseNoneFalse12485.660
3574782129934Nonecode114Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W( -KPWD - Elec Vol-VI, 2023-2024: Page No.43, Item No. 11.3.2)Each710.7710.722.0FalseNoneNoneFalseNoneFalse15635.40
3574783129934Nonecode115Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 36/40 W( -KPWD - Elec Vol-VI, 2023-2024: Page No.43, Item No. 11.3.3)Each1307.071307.0722.0FalseNoneNoneFalseNoneFalse28755.540
3574784129934Nonecode116Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 5-6W( -KPWD - Elec Vol-VI, 2023-2024: Page No.44, Item No. 11.5.1)Each588.13588.1320.0FalseNoneNoneFalseNoneFalse11762.60
3574785129934Nonecode117Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W( -KPWD - Elec Vol-VI,2023-2024: Page No.44, Item No. 11.5.2)Each911.55911.5520.0FalseNoneNoneFalseNoneFalse18231.00
3574786129934Nonecode118Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 15-18W( -KPWD - Elec Vol-VI, 2023-2024: Page No.44, Item No. 11.5.3)Each1363.721363.7225.0FalseNoneNoneFalseNoneFalse34093.00
3574787129934Nonecode119Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.-6A SP Switch-(KPWD - Elect,2023-2024: Page No.10, Item No. 3.14.1)Nos56.6556.6525.0FalseNoneNoneFalseNoneFalse1416.250
3574788129934Nonecode120Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bell Buzzer( -KPWD - Elec Vol-VI, 2023-2024: Page No.05, Item No. 3.14.9)Each133.9133.94.0FalseNoneNoneFalseNoneFalse535.60
3574789129934Nonecode121Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes , having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of JOints complete. (Internal Work Exprored on Wall) 25mm Nominal OD Pipe (KPWD -SR, 2023-2024 VOL-01 Page No.122, Item No. 13.31.3)m327.54327.5480.0FalseNoneNoneFalseNoneFalse26203.20
3574790129934Nonecode122Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of JOints complete.(Internal Work Exprored on Wall) 40mm Nominal OD Pipe (KPWD -SR, 2023-2024 VOL-01 Page No.122, Item No. 13.31.5)m552.08552.0875.0FalseNoneNoneFalseNoneFalse41406.00
3574791129934Nonecode123Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE Grade PE80-PN6.0,110mm dia(PWD SR 2023-2024, Vol-V, Pg No-95, It No-9.1.4)m483.07483.0780.0FalseNoneNoneFalseNoneFalse38645.60
3574792129934Nonecode124Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P.brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Range of three urinal basins with 10litre white P.V.C. automatic flush ing cistern(PWD SR 2023-2024, V-II, Pg No-131, It No-14.4.3)Each9738.659738.654.0FalseNoneNoneFalseNoneFalse38954.60
3574793129934Nonecode125Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid (PWD SR 2023-2024, V-II, Pg No-131, It No-14.2.1)Each4983.144983.144.0FalseNoneNoneFalseNoneFalse19932.560
3574794129934Nonecode126Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (PWD SR 2023-2024, V-II, Pg No-132, It No-14.7.1)Each3174.463174.463.0FalseNoneNoneFalseNoneFalse9523.380
3574795129934Nonecode127Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm(PWD SR 2023-2024, V-II, Pg No-136, It No-14.32.2)Each1048.541048.543.0FalseNoneNoneFalseNoneFalse3145.620
3574796129934Nonecode128Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (PWD SR 2023-2024, V-II, Pg No-131, It No-14.1.1)Each5030.525030.522.0FalseNoneNoneFalseNoneFalse10061.040
3574797129934Nonecode129Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. (PWD SR 2023-2024, V-II, Pg No-137, It No-14.40.1)Each492.34492.343.0FalseNoneNoneFalseNoneFalse1477.020
3574798129934Nonecode130Providing and fixing unplasticised PVC connection pipe with brass unions :15 mm nominal bore (PWD SR 2023-2024, V-II, Pg No-118, It No-13.8.1.1)Nos85.4985.498.0FalseNoneNoneFalseNoneFalse683.920
3574799129934Nonecode131S.C.I. gully or nahani grating 100 mm dia(PWD SR 2023-2024, V-II, Pg No-A34, It No-735)Nos32.032.04.0FalseNoneNoneFalseNoneFalse128.00
3574800129934Nonecode132Providing and fixing brass bib cock of approved quality 15 mm nominal bore: (PWD SR2023-2024, V-II, Pg No-117, It No-13.2.1)Nos294.58294.5820.0FalseNoneNoneFalseNoneFalse5891.60
3574801129934Nonecode133Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore (PWD SR 2023-2024, V-II, Pg No-117, It No-13.5.2)Nos323.42323.4220.0FalseNoneNoneFalseNoneFalse6468.40
3574802129934Nonecode134Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 g (PWD SR 2023-2024, V-II, Pg No-121, It No-13.24)Nos170.98170.9820.0FalseNoneNoneFalseNoneFalse3419.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17216286830000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17216286830000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17216286830001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17216286830000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17216286830000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17216287710000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17216287810000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17216287880000NoneNoneELIGIBILITYThe cost of the Tender form shall not be refundableNone
17216288010000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E - Procurement PortalNone
17216288110000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt orders.None
17216288200000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Bangalore dated 01.01.2007 and Government letter no PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fund/ etc., applies to latest order availableNone
17216288300000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejected.None
17216288380000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17216288460000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17216288540000NoneNoneELIGIBILITYThe tenderer should maintain the work during the defective liability period for 2 yearsNone
17216288620000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given Clause 29.1 of ITT for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with Clause 25.5 & 29.1 of ITT and Clause 44 of the Conditions of Contract.None
17216288710000NoneNoneELIGIBILITYContractor should take all precautions to ensure that no damage is caused to the existing works and other similar structures which have been constructed by other agencies during project execution. If any damage is caused, it has to be rectified at his own risk and cost.None
17216288780000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incidents happens on account of negligence or any project activity. Contractor should indemnify the client to that extent.None
17216288890000NoneNoneELIGIBILITYAll the items in the tender include all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and conveyance of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer in charge of this workNone
17216288980000NoneNoneELIGIBILITYContractor should follow strictly the prevailing rules of labour act.None
17216289110000NoneNoneELIGIBILITYAs per government order pwd 65 RDF 2017 dated:11/10/18 GST will be added to the contract amount separately.None
17216289250000NoneNoneELIGIBILITYIncrease in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneWork Done Certificates for the Work performed as Prime Contractor (in the same name) on works of similar nature during the five years specified Similar nature of Work done One work Constrction of BUILDING of value not less then Rs.99.96Lakhs 50% of amount put to tender.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Work Done Certificates for the Quantities of work executed as prime contractor (in the same name) during the last five years specified along with the details in the format as in the bid document.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLine of Credit i.e.Rs.50.83Lakhs 30% of amount put to tender obtained from Nationalized / Scheduled Banks in Given Pro-forma in the bid documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneValid contractor license certificate issued from competent authority in Appropriate Contractor ClassCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneValid GST Registration Certificate and Valid Labour Contractor LicenseCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneThe Information on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender. (A) Existing commitments and on-going works: along with the details in the format as in the bid documentCapabilities of Vendorongoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- On going work Details
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneprofit and loss statement in the name of the participating bidder.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneFinancial Turnover certificate obtained and certified by the Registered Valid Chartered Accountant indicating the Registration no of chartered accountant with UDIN Number Details (achieved in at least two financial years a minimum financial turnover of Rs 399.83 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonebalance sheet tallying the Annual Turn Over during the previous five years in the name of the participating bidderFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneITR Returns filed Copy in the name of the participating bidderFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneValid PAN Card of the Participating Bidder.OthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid PAN Card of the participating Bidder
NoneNoneNoneNoneSigned Copy by the Participating Agency on the Letter head containing the Address and Contact Details indication Contact Person & Designation, Contact Number Office Landline / Mobile, and valid email ID.OthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Address Document
NoneNoneNoneNoneNotary Self Attestation regarding Agreed to Terms and Conditions as per (bid document) kw4 on face value of Stamp Paper Rs 100.00.OthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Notery
NoneNoneNoneNoneNotary Affidavit Declaration that the bidder has not been blacklisted on Stamp paper of Face Value Rs 100.00.OthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Notery
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Work Done Certificates for the Work performed as Prime Contractor in the same name on works of similar nature during the five years specified Similar nature of Work done One work Constrction of BUILDING of value not less then Rs.99.96 Lakhs 50 of amount put to tender.TrueTechnical Bid
The Work Done Certificates for the Quantities of work executed as prime contractor in the same name during the last five years specified along with the details in the format as in the bid document.TrueTechnical Bid
Line of Credit i.e.Rs.50.83Lakhs 30 Percentage of amount put to tender obtained from Nationalized Scheduled Banks in Given Pro forma in the bid documentTrueTechnical Bid
Valid contractor license certificate issued from competent authority in Appropriate Contractor ClassTrueTechnical Bid
Valid GST Registration Certificate and Valid Labour Contractor LicenseTrueTechnical Bid
The Information on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender. A Existing commitments and on going works along with the details in the format as in the bid documentTrueTechnical Bid
The Tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical worksTrueTechnical Bid
profit and loss statement in the name of the participating bidderTrueTechnical Bid
Financial Turnover certificate obtained and certified by the Registered Valid Chartered Accountant indicating the Registration no of chartered accountant with UDIN Number Details achieved in at least two financial years a minimum financial turnover of Rs 399.83LakhsTrueTechnical Bid
balance sheet tallying the Annual Turn Over during the previous five years in the name of the participating bidderTrueTechnical Bid
ITR Returns filed Copy in the name of the participating bidderTrueTechnical Bid
Valid PAN Card of the Participating BidderTrueTechnical Bid
Signed Copy by the Participating Agency on the Letter head containing the Address and Contact Details indication Contact Person and Designation Contact Number Office Landline Mobile, and valid email IDTrueTechnical Bid
Notary Self Attestation regarding Agreed to Terms and Conditions as per bid document kw4 on face value of Stamp Paper Rs 100.00TrueTechnical Bid
Notary Affidavit Declaration that the bidder has not been blacklisted on Stamp paper of Face Value Rs 100.00.TrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsHaveriRattihalliDharwad SouthHIREKERURTP RATTIHALLINoneNoneNoneNoneNoneNone
tenderAddress
createdTs1721925081000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of Executive Engineer , District Urban Development Cell Haveri
streetNone
cityHaveri
stateKarnataka
pin581110
tenderRecallDTONone