1722665425000 | 0 | None | None | Buildings | Construction of 4 rooms for Boys Govt PU College in CTA town (ST category) | 8313261.02 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3679614 | 134771 | None | Vol.I, 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery &other appurtenances required to complete the In all kinds of soils upto 300 mm depth work | Cum | 97.85 | 97.85 | 112.5 | False | None | None | False | None | False | 11008.125 | 0 | 3679615 | 134771 | None | Vol.I, 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 257.05 | False | None | None | False | None | False | 27005.673 | 0 | 3679616 | 134771 | None | Vol.I, 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead lift, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1 4 8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5833.92 | 5833.92 | 32.21 | False | None | None | False | None | False | 187910.5632 | 0 | 3679617 | 134771 | None | Vol.I, 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works The granite trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & liftscost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6842.88 | 6842.88 | 59.03 | False | None | None | False | None | False | 403935.2064 | 0 | 3679618 | 134771 | None | Vol.I, 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works The granite trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & liftscost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10961.28 | 10961.28 | 3.56 | False | None | None | False | None | False | 39022.1568 | 0 | 3679619 | 134771 | None | Vol.II, 5.3 | Providing Coursed rubble masonrysecond sort with hard stone in foundation plinth with Cement mortar 1 6 1 cement 6 coarse sand) | Cum | 6391.15 | 6391.15 | 63.07 | False | None | None | False | None | False | 403089.8305 | 0 | 3679620 | 134771 | None | Vol.II, 5.4 | Providing Size Stone masonry with hard stone in foundation plinth with Cement mortar 1 6 | Cum | 6580.67 | 6580.67 | 29.83 | False | None | None | False | None | False | 196301.3861 | 0 | 3679621 | 134771 | None | Vol.I, 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead lifts cost of all materials of quality, labour Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11210.4 | 11210.4 | 1.84 | False | None | None | False | None | False | 20627.136 | 0 | 3679622 | 134771 | None | Vol.I, 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead lifts cost of all materials of quality, labour Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate | Cum | 10562.4 | 10562.4 | 19.57 | False | None | None | False | None | False | 206706.168 | 0 | 3679623 | 134771 | None | Vol.I, 2.11 | Supplying fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery labourcleaning, straightening, cutting, bending, hooking, laping welding joints tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | MT | 92140.71 | 92140.71 | 4.38 | False | None | None | False | None | False | 403576.3098 | 0 | 3679624 | 134771 | None | Vol.II, 8.3.1 | Providing 20 mm cement plaster of mix 1:4 1 cement: 4 fine sand to brick stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 364.62 | 364.62 | 85.78 | False | None | None | False | None | False | 31277.1036 | 0 | 3679625 | 134771 | None | Vol.I, 1.9 | Filling available excavated earthexcluding rock in trenches plinth, sides of foundations and other similar works etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 273.98 | 273.98 | 257.05 | False | None | None | False | None | False | 70426.559 | 0 | 3679626 | 134771 | None | Vol.I, 1.9 | Filling available excavated earthexcluding rock in trenches plinth, sides of foundations and other similar works etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 511.92 | 511.92 | 134.83 | False | None | None | False | None | False | 69022.1736 | 0 | 3679627 | 134771 | None | Vol.II, 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 1 cement 6 coarse sand) including cost of all materials labour scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8208.07 | 8208.07 | 99.04 | False | None | None | False | None | False | 812927.2528 | 0 | 3679628 | 134771 | None | Vol.I, 2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 12 4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6430.29 | 6430.29 | 5.83 | False | None | None | False | None | False | 37488.5907 | 0 | 3679629 | 134771 | None | Vol.II, 11.32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(P.NO.84.I.NO.11.32 PWD SR 2023-24Volme II) for columns | Cum | 11838.39 | 11838.39 | 16.77 | False | None | None | False | None | False | 198529.8003 | 0 | 3679630 | 134771 | None | Vol.II, 11.32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(P.NO.84.I.NO.11.32 PWD SR 2023-24Volme II) for columns | Cum | 11154.09 | 11154.09 | 38.28 | False | None | None | False | None | False | 426978.5652 | 0 | 3679631 | 134771 | None | Vol.II, 11.32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(P.NO.84.I.NO.11.32 PWD SR 2023-24Volme II) for columns | Cum | 10469.79 | 10469.79 | 67.43 | False | None | None | False | None | False | 705977.9397 | 0 | 3679632 | 134771 | None | Vol.II, 11.32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(P.NO.84.I.NO.11.32 PWD SR 2023-24Volme II) for columns | Cum | 10127.64 | 10127.64 | 0.97 | False | None | None | False | None | False | 9823.8108 | 0 | 3679633 | 134771 | None | Vol.I, 2.11 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all aterials, machinery labour cleaning, straightening, cutting, bending, hooking, laping welding joints tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | MT | 92140.71 | 92140.71 | 12.82 | False | None | None | False | None | False | 1181243.9022 | 0 | 3679634 | 134771 | None | Vol.II, 11.3 | Providing and fixing in position collapsible steel shutters with vertical channels 20102 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge | Sqm | 8524.28 | 8524.28 | 6.3 | False | None | None | False | None | False | 53702.964 | 0 | 3679635 | 134771 | None | Vol.II, 11.5.1 | Providing and fixing 1mm thick MS sheet door with frame of 40406 mm angle iron and 3 mm MS gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using MS angels 40406 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge | Sqm | 4612.34 | 4612.34 | 51.3 | False | None | None | False | None | False | 236613.042 | 0 | 3679636 | 134771 | None | Vol.I, 11.34A | Providing and fixing MS grills of required pattern in frames of windows etc. with MS. flats square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 812.7 | False | None | None | False | None | False | 140629.608 | 0 | 3679637 | 134771 | None | Vol.1 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness well compacted using plate vibrators, including all lead and lifts cost of all materials of quality labour Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1 4 8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5833.92 | 5833.92 | 35.62 | False | None | None | False | None | False | 207804.2304 | 0 | 3679638 | 134771 | None | Vol.II,9.31 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm averagethick base of cement mortar 1 4 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the EngineerinCharge | Sqm | 2147.55 | 2147.55 | 470.31 | False | None | None | False | None | False | 1010014.2405 | 0 | 3679639 | 134771 | None | Vol.II,8.4.2 | Providing 12 mm cement plasterfinished with a floating coat of neat cement of mix 1 4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineerincharge | Sqm | 321.36 | 321.36 | 594.83 | False | None | None | False | None | False | 191154.5688 | 0 | 3679640 | 134771 | None | Vol.II, 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 14 1cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding including cost of materials, labour curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 359.47 | 359.47 | 761.55 | False | None | None | False | None | False | 273754.3785 | 0 | 3679641 | 134771 | None | Vol.II, 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New wor two coats over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 141.11 | 141.11 | 1073.85 | False | None | None | False | None | False | 151530.9735 | 0 | 3679642 | 134771 | None | Vol.II, 8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials, labour complete as per specifications and as per directions of Engineerin charge | Sqm | 54.59 | 54.59 | 791.79 | False | None | None | False | None | False | 43223.8161 | 0 | 3679643 | 134771 | None | Vol.II, 8.28 | Finishing walls with water proofing cement paint of required shadeNew work Two coats applied 4 84 kg10 m to give an even shade after thoroughly brooming the surface to remove all dirt dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 91.67 | 91.67 | 791.79 | False | None | None | False | None | False | 72583.3893 | 0 | 3679644 | 134771 | None | Vol.II, 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 118.45 | 118.45 | 108.9 | False | None | None | False | None | False | 12899.205 | 0 | 3679645 | 134771 | None | Vol.II, 13.64.2 | Providing and fixing Sewer SWR pipes including all fittings This includes jointing of pipes fittings with one step solvent cement trenching, refilling testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | Mtr | 396.55 | 396.55 | 54.0 | False | None | None | False | None | False | 21413.7 | 0 | 3679646 | 134771 | None | Vol.II, 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing balcony railing, staircase railing and similar works including applying priming coat of approved steel primer. MS.tube including cost of materials, labour usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 142.14 | 142.14 | 283.5 | False | None | None | False | None | False | 40296.69 | 0 | 3679647 | 134771 | None | Vol.II, 8.84 | Providing wall black boards in 12mm thick with CM 1 3 and applied with primer two coats of acrylic emulsion black paint including finishing etc.,complete. | Sqm | 489.25 | 489.25 | 36.0 | False | None | None | False | None | False | 17613.0 | 0 | 3679648 | 134771 | None | Vol.II, 7.38 | Providing and fixing precoated galvanised iron profile sheets ize shape and pitch of corrugation as approved by Engineer-in-charge 0.50 mm 005percentage total coated thickness with zinc coating 120 gm2 as per IS 277 in 240 mpa steel grade 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size5.5x 55 mm with EPDM seal complete upto any pitch in horizontal vertical or curved surfaces, excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required | Sqm | 585.04 | 585.04 | 27.68 | False | None | None | False | None | False | 16193.9072 | 0 | 3679649 | 134771 | None | Vol.II, 11.16.2 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc trusses etc including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc complete Hot finished seamless type tubes including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge | Kg | 151.41 | 151.41 | 100.0 | False | None | None | False | None | False | 15141.0 | 0 | 3679650 | 134771 | None | Vol.II, 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400 and tensile strength greater than 2MP as per ASTM D412 The waterproofing membrane to be applied in 2coats at 1.6 kgm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at 150 gm2 and protection with 120gsm Geo textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing treatment of construction joints completely as per specification | Sqm | 841.51 | 841.51 | 202.29 | False | None | None | False | None | False | 170229.0579 | 0 | 3679651 | 134771 | None | Eltrcl, 1.2.2 | Supplying heavy gauge PVC conduit pipe mm di 25mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick | Mtr | 78.0 | 78.0 | 200.0 | False | None | None | False | None | False | 15600.0 | 0 | 3679652 | 134771 | None | Eltrcl, 1.1.2 | Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 1920 mm dia 2 mm thick | Mtr | 81.0 | 81.0 | 150.0 | False | None | None | False | None | False | 12150.0 | 0 | 3679653 | 134771 | None | Eltrcl, 1.4.7 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200 200 mm | Each | 348.0 | 348.0 | 10.0 | False | None | None | False | None | False | 3480.0 | 0 | 3679654 | 134771 | None | Eltrcl, 1.5.1 | Supplying and fixing PVC metal conduit Deep junction box 19 20mm deep Junction box | Each | 49.0 | 49.0 | 50.0 | False | None | None | False | None | False | 2450.0 | 0 | 3679655 | 134771 | None | Eltrcl, 2.1.1 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 21.5mm2 Phase and Neutral and 11.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments with 6A flush type SP control switch shall be fixed on the existing plastic shee gang box, the other end of the wires shall be terminated with sufficient loose length in a woodPVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch | Each | 285.0 | 285.0 | 12.0 | False | None | None | False | None | False | 3420.0 | 0 | 3679656 | 134771 | None | Eltrcl, 2.1.2 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 2 1.5mm2 Phase and Neutral and 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments with 6A flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet.Short point upto 3m from tapping point to out let via switch Medium point above 3m upto 6m from tapping point to out let via switch | Each | 394.0 | 394.0 | 20.0 | False | None | None | False | None | False | 7880.0 | 0 | 3679657 | 134771 | None | Eltrcl, 2.1.3 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 2 1.5mm2 Phase and Neutra and 1 1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch Medium point above 3m upto 6m from tapping point to out let via switch Long point above 6m upto 10m from tapping point to out let via switch | Each | 570.0 | 570.0 | 10.0 | False | None | None | False | None | False | 5700.0 | 0 | 3679658 | 134771 | None | Eltrcl, 3.6.3 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 3679659 | 134771 | None | Eltrcl, 3.6.9 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 | 3679660 | 134771 | None | Eltrcl, 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc and fixing on existing wooden or metal box using NFscrews | Sqm | 0.41 | 0.41 | 4000.0 | False | None | None | False | None | False | 1640.0 | 0 | 3679661 | 134771 | None | Eltrcl, 5.19.5 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required cl\, bolts nuts etc with provision for fixing suitable type capacity MCBs single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure.16 Way SP and N | Each | 2932.0 | 2932.0 | 4.0 | False | None | None | False | None | False | 11728.0 | 0 | 3679662 | 134771 | None | Eltrcl, 5.20.4 | Supplying fixing and wiring Earth LeakageMiniature Circuit Breaker ELMCB 240 450V upto 300mA sensitivity on existing wood/panel board.63 A 4 pole | Each | 4559.0 | 4559.0 | 4.0 | False | None | None | False | None | False | 18236.0 | 0 | 3679663 | 134771 | None | Eltrcl, 11.11.7 | Supplying and fixing retrofit type PLLED Lamp W LED linear source with CCT 6500 degree KCRI 70 percentage Efficacy 80 lumen per W.life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95 power loss should 5percentage of lamp Wage short circuit and open circuit protection to be integrated in the circuit THD less than 20percentage Life as per LM 79.The operating input voltage should be between 130 to275 V Tested by NABLCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition | Each | 426.0 | 426.0 | 24.0 | False | None | None | False | None | False | 10224.0 | 0 | 3679664 | 134771 | None | Eltrcl, 13.5 | Fixing halogen metal halide SV IL LED floodlight fitting over existing pole wall ceiling including clA bolts nuts and wiring using suitable capacity wires | Each | 162.0 | 162.0 | 24.0 | False | None | None | False | None | False | 3888.0 | 0 | 3679665 | 134771 | None | Eltrcl, 2.3.1 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments.1mm2 | Mtr | 19.0 | 19.0 | 400.0 | False | None | None | False | None | False | 7600.0 | 0 | 3679666 | 134771 | None | Eltrcl, 2.3.2 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments1mm2 1.5 mm2 | Mtr | 26.0 | 26.0 | 300.0 | False | None | None | False | None | False | 7800.0 | 0 | 3679667 | 134771 | None | Eltrcl, 2.3.3 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments. 1mm22.5 mm2 | Mtr | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 | 3679668 | 134771 | None | Eltrcl, 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etc for operation on 230 V 50 cycles Single phase AC supply conforming to ISS 374 1979 and with double ball bearing system 56 Sweep 1400 mm Regular model | Each | 3031.0 | 3031.0 | 20.0 | False | None | None | False | None | False | 60620.0 | 0 | 3679669 | 134771 | None | Eltrcl, 2.3.4 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments. 4mm2 | Mtr | 63.0 | 63.0 | 50.0 | False | None | None | False | None | False | 3150.0 | 0 | 3679670 | 134771 | None | Eltrcl, 5.18.3 | Supplying fixing miniature circuit breaker son existing MCB distribution boards using necessary fixing material sand C Type curve indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 50 63 A SP | Mtr | 811.0 | 811.0 | 1.0 | False | None | None | False | None | False | 811.0 | 0 | 3679671 | 134771 | None | Eltrcl, 5.19.4 | Supplying and fixing regular MCB distribution board on wall/woodboard flush mounting using required clamps bolts nutsetc with provision for fixing suitable type capacity MCB using phase 3phase single door with powder coated painting Made out of 14SWGMS enclosure.I Single Door12 Way SP N | Mtr | 1863.0 | 1863.0 | 4.0 | False | None | None | False | None | False | 7452.0 | 0 | 3679672 | 134771 | None | Eltrcl, 13.10 | Fixing a ceiling Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 A ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ( P No 57/105 It no13.10) Electrical SR 2023-24) | Each | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 |
|