createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723183023921
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee960.00
emd95500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose16-08-2024 16:30:00
tenderQueryClose16-08-2024 13:00:00
technicalBidOpen17-08-2024 16:40:00
publishedDate09-08-2024 12:16:13
publishedByPostTMC_CO_DVDG
publishedByUserKPE15275 - K HAMPAYYA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonS M Hasan
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8050568804
tenderSupplierListNone
tenderSchedule
createdTs1723183023953
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT25790
titleConstruction of Proposed 5TPD Material Recovery Facility of PEB Structure Primary Shed at Sy No 52 in Devadurga Town
descriptionConstruction of Proposed 5TPD Material Recovery Facility of PEB Structure Primary Shed at Sy No 52 in Devadurga Town
categoryWORKS
categoryTextWorks
ecv3820000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2375
locationNameDMA Town Municipal Council Devadurga
provisionalAmount3820000.0
groupOverheadTotal612086.96
fileNumberTMC/SBMSSWM/MaterialRecoveryFacility/DEV/97
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17231830240000NoneNoneOther WorksConstruction of Proposed 5TPD Material Recovery Facility of PEB Structure Primary Shed at Sy No 52 in Devadurga Town3207913.04
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3733800138959Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.Cum107.1107.136.64FalseNoneNoneFalseNoneFalse3924.1440
3733801138959Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately.Cum5947.25947.236.18FalseNoneNoneFalseNoneFalse215169.6960
3733802138959Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum7322.47322.49.04FalseNoneNoneFalseNoneFalse66194.4960
3733803138959Nonecode04Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum11016.011016.01.94FalseNoneNoneFalseNoneFalse21371.040
3733804138959Nonecode05Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum7322.47322.440.7FalseNoneNoneFalseNoneFalse298021.680
3733805138959Nonecode06Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9820.89820.85.98FalseNoneNoneFalseNoneFalse58728.3840
3733806138959Nonecode07Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.MT93929.8593929.853.708FalseNoneNoneFalseNoneFalse348291.88380
3733807138959Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) .Cum6708.456708.4517.43FalseNoneNoneFalseNoneFalse116928.28350
3733808138959Nonecode09Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum497.7497.7183.14FalseNoneNoneFalseNoneFalse91148.7780
3733809138959Nonecode10Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1292.551292.5515.91FalseNoneNoneFalseNoneFalse20564.47050
3733810138959Nonecode11Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75225.61FalseNoneNoneFalseNoneFalse69882.69750
3733811138959Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.Kgs118.65118.658380.0FalseNoneNoneFalseNoneFalse994287.00
3733812138959Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm596.4596.4590.76FalseNoneNoneFalseNoneFalse352329.2640
3733813138959Nonecode14Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0225.61FalseNoneNoneFalseNoneFalse23689.050
3733814138959Nonecode15Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.No76.6576.65106.0FalseNoneNoneFalseNoneFalse8124.90
3733815138959Nonecode16Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.No76.6576.65106.0FalseNoneNoneFalseNoneFalse8124.90
3733816138959Nonecode17Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2764.652764.6522.5FalseNoneNoneFalseNoneFalse62204.6250
3733817138959Nonecode18Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.No25920.325920.32.0FalseNoneNoneFalseNoneFalse51840.60
3733818138959Nonecode19Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..Kgs476.6476.6240.0FalseNoneNoneFalseNoneFalse114384.00
3733819138959Nonecode20LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. Main Panel Incomer : MCCB TPN 63A with CBCT ELR & Ph indicators, meter section with all parameters as required 100A 4 Wire 25kA 415V Aluminium busbars compartment. Outgoings: 63A MCCB feeder- 01No. Outgoings: 16A MPCB feeder - 01Nos Outgoings: 16A MPCB feeder - 02Nos Outgoings: 63/40A MCB feeder- 08NosNo68250.068250.01.0FalseNoneNoneFalseNoneFalse68250.00
3733820138959Nonecode21Sub panel-1 Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required 63A 4 Wire 16kA 415V Aluminium busbars compartment. Outgoings: 40/63A 4P MCB feeder- 10No. Outgoings: 32A Industrial socket-02Nos. Outgoings: 16A Industrial socket-02Nos.No36750.036750.01.0FalseNoneNoneFalseNoneFalse36750.00
3733821138959Nonecode22Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3.5Cx50 Sqmm Al Ar cablem315.0315.030.0FalseNoneNoneFalseNoneFalse9450.00
3733822138959Nonecode23Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx25 Sqmm Al Ar cablem189.0189.020.0FalseNoneNoneFalseNoneFalse3780.00
3733823138959Nonecode24Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx16 Sqmm Al Ar cablem126.0126.020.0FalseNoneNoneFalseNoneFalse2520.00
3733824138959Nonecode25Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx10 Sqmm Cu Ar cablem348.6348.61.0FalseNoneNoneFalseNoneFalse348.60
3733825138959Nonecode26Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx6.0 Sqmm Cu Ar cablem268.8268.81.0FalseNoneNoneFalseNoneFalse268.80
3733826138959Nonecode27Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3Cx6.0 Sqmm Cu Un Ar cablem331.8331.81.0FalseNoneNoneFalseNoneFalse331.80
3733827138959Nonecode28Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3Cx4.0 Sqmm Cu Un Ar cablem315.0315.01.0FalseNoneNoneFalseNoneFalse315.00
3733828138959Nonecode29Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cableSet210.0210.02.0FalseNoneNoneFalseNoneFalse420.00
3733829138959Nonecode30Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx25 Sqmm Al Ar cableSet70.5670.562.0FalseNoneNoneFalseNoneFalse141.120
3733830138959Nonecode31Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx16 Sqmm Al Ar cableSet70.5670.562.0FalseNoneNoneFalseNoneFalse141.120
3733831138959Nonecode32Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx10 Sqmm Cu Ar cableSet57.1257.122.0FalseNoneNoneFalseNoneFalse114.240
3733832138959Nonecode33Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx6.0 Sqmm Cu Ar cableSet57.1257.122.0FalseNoneNoneFalseNoneFalse114.240
3733833138959Nonecode34Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3Cx6.0 Sqmm Cu Un Ar cableSet57.1257.122.0FalseNoneNoneFalseNoneFalse114.240
3733834138959Nonecode35Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3Cx4.0 Sqmm Cu Un Ar cableSet57.1257.122.0FalseNoneNoneFalseNoneFalse114.240
3733835138959Nonecode36Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 70 Sqmm Al Ar cable (tinned copper lug)Set262.5262.52.0FalseNoneNoneFalseNoneFalse525.00
3733836138959Nonecode37Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 25 Sqmm Al Ar cable (tinned copper lug)Set16.816.82.0FalseNoneNoneFalseNoneFalse33.60
3733837138959Nonecode38Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 16 Sqmm Al Ar cable (tinned copper lug)Set10.4510.452.0FalseNoneNoneFalseNoneFalse20.90
3733838138959Nonecode39Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 10 Sqmm Cu Ar cable (tinned copper lug)Set6.726.721.0FalseNoneNoneFalseNoneFalse6.720
3733839138959Nonecode40Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 6.0 Sqmm Cu Ar cable (tinned copper lug)Set5.885.881.0FalseNoneNoneFalseNoneFalse5.880
3733840138959Nonecode41Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 6.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.885.881.0FalseNoneNoneFalseNoneFalse5.880
3733841138959Nonecode42Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 4.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.885.881.0FalseNoneNoneFalseNoneFalse5.880
3733842138959Nonecode43Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduitm71.471.410.0FalseNoneNoneFalseNoneFalse714.00
3733843138959Nonecode44Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 25mm dia PVC 2mm thick conduitm84.084.010.0FalseNoneNoneFalseNoneFalse840.00
3733844138959Nonecode45Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 32mm dia PVC 2mm thick conduitm105.0105.01.0FalseNoneNoneFalseNoneFalse105.00
3733845138959Nonecode46Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 40mm dia PVC 2mm thick conduitm118.65118.651.0FalseNoneNoneFalseNoneFalse118.650
3733846138959Nonecode47Point wiring using Copper wire with switch. Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point upto 3Mtr from switch boardNo289.8289.81.0FalseNoneNoneFalseNoneFalse289.80
3733847138959Nonecode48Point wiring using Copper wire with switch. Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point above 3M upto 6Mtr from switch boardNo405.3405.31.0FalseNoneNoneFalseNoneFalse405.30
3733848138959Nonecode49Point wiring using Copper wire with switch. Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point above 6M upto 10Mtr from switch boardNo595.35595.351.0FalseNoneNoneFalseNoneFalse595.350
3733849138959Nonecode50Point wiring using Copper wire with switch. Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 3Mtr upto 6Mtr from switch boardNo757.05757.051.0FalseNoneNoneFalseNoneFalse757.050
3733850138959Nonecode51Point wiring using Copper wire with switch. Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 6Mtr upto 10Mtr from switch boardNo757.05757.051.0FalseNoneNoneFalseNoneFalse757.050
3733851138959Nonecode52Point wiring using Copper wire with switch. Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 3 Light point above 6Mtr upto 10Mtr from switch boardNo1106.71106.73.0FalseNoneNoneFalseNoneFalse3320.10
3733852138959Nonecode53Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wirem18.918.9300.0FalseNoneNoneFalseNoneFalse5670.00
3733853138959Nonecode54Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.5 Sqmm Cu FRLS wirem27.327.3300.0FalseNoneNoneFalseNoneFalse8190.00
3733854138959Nonecode55Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 2.5 Sqmm Cu FRLS wirem42.042.0300.0FalseNoneNoneFalseNoneFalse12600.00
3733855138959Nonecode56Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 4.0 Sqmm Cu FRLS wirem61.9561.9550.0FalseNoneNoneFalseNoneFalse3097.50
3733856138959Nonecode57Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 6.0 Sqmm Cu FRLS wirem120.75120.7550.0FalseNoneNoneFalseNoneFalse6037.50
3733857138959Nonecode5810 - 12 Way Polycarbonate switch box plateNo381.15381.154.0FalseNoneNoneFalseNoneFalse1524.60
3733858138959Nonecode5916 - 18 Way Polycarbonate switch box plateNo496.65496.654.0FalseNoneNoneFalseNoneFalse1986.60
3733859138959Nonecode60Switches & sockets outlets in Existing modular box 6A one way switchNo92.492.44.0FalseNoneNoneFalseNoneFalse369.60
3733860138959Nonecode61Switches & sockets outlets in Existing modular box 6A Two way switchNo159.6159.64.0FalseNoneNoneFalseNoneFalse638.40
3733861138959Nonecode62Switches & sockets outlets in Existing modular box 6A 5Pin socketNo170.1170.12.0FalseNoneNoneFalseNoneFalse340.20
3733862138959Nonecode63Switches & sockets outlets in Existing modular box Stepped fan regulatorNo328.65328.652.0FalseNoneNoneFalseNoneFalse657.30
3733863138959Nonecode64Switches & sockets outlets in Existing modular box 6/16A Universal socketNo261.45261.452.0FalseNoneNoneFalseNoneFalse522.90
3733864138959Nonecode65Supply & fixing of 50W LED light fixture IP 65, included screws accessoris Etc..Considered outdoor type light fitting for equivalent.No7759.57759.510.0FalseNoneNoneFalseNoneFalse77595.00
3733865138959Nonecode66Earthing 25x6mm GI Earth Stripm96.696.660.0FalseNoneNoneFalseNoneFalse5796.00
3733866138959Nonecode67Earthing 8.0 SWG GI bare wirem15.9615.9650.0FalseNoneNoneFalseNoneFalse798.00
3733867138959Nonecode68Supply & installation of GI Ladder type cable tray 300x50mmm420.0420.020.0FalseNoneNoneFalseNoneFalse8400.00
3733868138959Nonecode69Supply & installation of GI PIPE Earthing as per IS:3043 with all installation detailsNo8400.08400.02.0FalseNoneNoneFalseNoneFalse16800.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17231830270000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17231830270000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17231830270000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17231830270000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17231830270000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneEnclose Similar Nature Quantitywise Workdone Certificate not less than 50% of the Estimate Cost by Suitable Rank OfficerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid PWD Registration Certificate Class 2 and AboveCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneValid GST Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneLatest Annual Turnover Certificate of 5 Years issued by Chartered Accountant from 2019-20 to 2023-24Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneUnconditional Line of Credit of 50 percentage of Amount put to tender on Bank LetterheadFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration Certificate Class 2 and AboveTrueTechnical Bid
Valid GST Registration certificateTrueTechnical Bid
Similar Nature Quantitywise Work done Certificate not less than 50 percent amount put to tender by suitable Rank OfficerTrueTechnical Bid
Latest Annual Turnover Certificate of 5 Years issued by Chartered Accountant from 2019-20 to 2023-24TrueTechnical Bid
Unconditional Line of Credit of 50 percentage of Amount put to tender on Bank LetterheadTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone