tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1723107799000 | 0 | None | None | Other Works | 1Construction of Public Toilet at Wno7 in Bheem Nagar Aland of Mini Highmast at wno 11 at Aland | 412321.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3723950 | 138075 | None | 001 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle
| Sqm | 412.65 | 412.65 | 0.102 | False | None | None | False | None | False | 42.0903 | 0 | 3723951 | 138075 | None | 002 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 21.76 | False | None | None | False | None | False | 2330.496 | 0 | 3723952 | 138075 | None | 003 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 0.86 | False | None | None | False | None | False | 5114.592 | 0 | 3723953 | 138075 | None | 004 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6948.9 | 6948.9 | 2.59 | False | None | None | False | None | False | 17997.651 | 0 | 3723954 | 138075 | None | 005 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6708.45 | 6708.45 | 2.47 | False | None | None | False | None | False | 16569.8715 | 0 | 3723955 | 138075 | None | 006 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6601.35 | 6601.35 | 0.97 | False | None | None | False | None | False | 6403.3095 | 0 | 3723956 | 138075 | None | 007 | Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other types
| Cum | 198.04 | 198.04 | 0.97 | False | None | None | False | None | False | 192.0988 | 0 | 3723957 | 138075 | None | 008 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates
| Cum | 6961.5 | 6961.5 | 1.13 | False | None | None | False | None | False | 7866.495 | 0 | 3723958 | 138075 | None | 009 | Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & Piers
| Cum | 4873.05 | 4873.05 | 1.13 | False | None | None | False | None | False | 5506.5465 | 0 | 3723959 | 138075 | None | 0010 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates
| Cum | 6961.5 | 6961.5 | 2.23 | False | None | None | False | None | False | 15524.145 | 0 | 3723960 | 138075 | None | 0011 | Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building
| Cum | 4176.9 | 4176.9 | 2.23 | False | None | None | False | None | False | 9314.487 | 0 | 3723961 | 138075 | None | 0012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates
| Cum | 6961.5 | 6961.5 | 2.15 | False | None | None | False | None | False | 14967.225 | 0 | 3723962 | 138075 | None | 0013 | Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched)
| Cum | 3480.75 | 3480.75 | 2.15 | False | None | None | False | None | False | 7483.6125 | 0 | 3723963 | 138075 | None | 0014 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings
| Cum | 93929.85 | 93929.85 | 0.33 | False | None | None | False | None | False | 30996.8505 | 0 | 3723964 | 138075 | None | 0015 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8621.55 | 8621.55 | 10.34 | False | None | None | False | None | False | 89146.827 | 0 | 3723965 | 138075 | None | 0016 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 130412.1 | 130412.1 | 0.106 | False | None | None | False | None | False | 13823.6826 | 0 | 3723966 | 138075 | None | 0017 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)
| Sqm | 7816.2 | 7816.2 | 2.1 | False | None | None | False | None | False | 16414.02 | 0 | 3723967 | 138075 | None | 0018 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
| Mtr | 498.75 | 498.75 | 22.8 | False | None | None | False | None | False | 11371.5 | 0 | 3723968 | 138075 | None | 0019 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges do- with one side prelam
| Sqm | 2142.0 | 2142.0 | 6.3 | False | None | None | False | None | False | 13494.6 | 0 | 3723969 | 138075 | None | 0020 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 111.3 | 111.3 | 45.36 | False | None | None | False | None | False | 5048.568 | 0 | 3723970 | 138075 | None | 0021 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 6.62 | False | None | None | False | None | False | 1675.191 | 0 | 3723971 | 138075 | None | 0022 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 389.55 | 389.55 | 108.34 | False | None | None | False | None | False | 42203.847 | 0 | 3723972 | 138075 | None | 0023 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.
| Sqm | 1622.25 | 1622.25 | 2.3 | False | None | None | False | None | False | 3731.175 | 0 | 3723973 | 138075 | None | 0024 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 933.45 | 933.45 | 3.51 | False | None | None | False | None | False | 3276.4095 | 0 | 3723974 | 138075 | None | 0025 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 143.85 | 143.85 | 47.19 | False | None | None | False | None | False | 6788.2815 | 0 | 3723975 | 138075 | None | 0026 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 93.45 | 93.45 | 30.76 | False | None | None | False | None | False | 2874.522 | 0 | 3723976 | 138075 | None | 0027 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 144.9 | 144.9 | 7.16 | False | None | None | False | None | False | 1037.484 | 0 | 3723977 | 138075 | None | 0028 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 145.95 | 145.95 | 2.16 | False | None | None | False | None | False | 315.252 | 0 | 3723978 | 138075 | None | 0029 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
| Each | 5128.2 | 5128.2 | 4.0 | False | None | None | False | None | False | 20512.8 | 0 | 3723979 | 138075 | None | 0030 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
| Each | 3009.3 | 3009.3 | 1.0 | False | None | None | False | None | False | 3009.3 | 0 | 3723980 | 138075 | None | 0031 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
| Each | 1812.3 | 1812.3 | 1.0 | False | None | None | False | None | False | 1812.3 | 0 | 3723981 | 138075 | None | 0032 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc
| Each | 6764.1 | 6764.1 | 1.0 | False | None | None | False | None | False | 6764.1 | 0 | 3723982 | 138075 | None | 0033 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3
| Mtr | 431.55 | 431.55 | 10.0 | False | None | None | False | None | False | 4315.5 | 0 | 3723983 | 138075 | None | 0034 | Providing and fixing unplasticised PVC connection pipe with brass
unions :20 mm nominal bore | Nos | 115.5 | 115.5 | 20.0 | False | None | None | False | None | False | 2310.0 | 0 | 3723984 | 138075 | None | 0035 | Providing and fixing brss bib cock of approved quality etc.,
| Nos | 320.25 | 320.25 | 6.0 | False | None | None | False | None | False | 1921.5 | 0 | 3723985 | 138075 | None | 0036 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
| Nos | 627.9 | 627.9 | 4.0 | False | None | None | False | None | False | 2511.6 | 0 | 3723986 | 138075 | None | 0037 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore
| Nos | 320.25 | 320.25 | 4.0 | False | None | None | False | None | False | 1281.0 | 0 | 3723987 | 138075 | None | 0038 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
| l | 9.45 | 9.45 | 500.0 | False | None | None | False | None | False | 4725.0 | 0 | 3723988 | 138075 | None | 0039 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick
| Mtr | 81.9 | 81.9 | 15.0 | False | None | None | False | None | False | 1228.5 | 0 | 3723989 | 138075 | None | 0040 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick
| Mtr | 82.95 | 82.95 | 15.0 | False | None | None | False | None | False | 1244.25 | 0 | 3723990 | 138075 | None | 0041 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box
| Each | 58.8 | 58.8 | 10.0 | False | None | None | False | None | False | 588.0 | 0 | 3723991 | 138075 | None | 0042 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm)
| Each | 117.6 | 117.6 | 2.0 | False | None | None | False | None | False | 235.2 | 0 | 3723992 | 138075 | None | 0043 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm)
| Each | 90.3 | 90.3 | 2.0 | False | None | None | False | None | False | 180.6 | 0 | 3723993 | 138075 | None | 0044 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4" x 4" x 3" ( 101 x 101 x 76 mm
| Each | 77.7 | 77.7 | 2.0 | False | None | None | False | None | False | 155.4 | 0 | 3723994 | 138075 | None | 0045 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm)
| Each | 120.75 | 120.75 | 1.0 | False | None | None | False | None | False | 120.75 | 0 | 3723995 | 138075 | None | 0046 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switch
| Point | 299.25 | 299.25 | 2.0 | False | None | None | False | None | False | 598.5 | 0 | 3723996 | 138075 | None | 0047 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switch
| Point | 413.7 | 413.7 | 2.0 | False | None | None | False | None | False | 827.4 | 0 | 3723997 | 138075 | None | 0048 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 8C x 1.5 mm2
| Mtr | 165.9 | 165.9 | 15.0 | False | None | None | False | None | False | 2488.5 | 0 | 3723998 | 138075 | None | 0049 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way
| Each | 154.35 | 154.35 | 3.0 | False | None | None | False | None | False | 463.05 | 0 | 3723999 | 138075 | None | 0050 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way
| Each | 134.4 | 134.4 | 3.0 | False | None | None | False | None | False | 403.2 | 0 | 3724000 | 138075 | None | 0051 | Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293
| Each | 186.9 | 186.9 | 2.0 | False | None | None | False | None | False | 373.8 | 0 | 3724001 | 138075 | None | 0052 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 Way
| Each | 108.15 | 108.15 | 2.0 | False | None | None | False | None | False | 216.3 | 0 | 3724002 | 138075 | None | 0053 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way
| Each | 143.85 | 143.85 | 2.0 | False | None | None | False | None | False | 287.7 | 0 | 3724003 | 138075 | None | 0054 | Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRI 70 efficacy 80 lumen per W life 25000 burning hours and Compliance to IS 10322 IEC 60598 LM 79 LM 80The LED are driven by HF electronic driver integrated in the system, with PF 0.95power loss should 5of lamp Wage., short circuit open circuit protection to be integrated in the circuit,THD less than Life as per LM 7 The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABLCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W6500K | Each | 447.3 | 447.3 | 5.0 | False | None | None | False | None | False | 2236.5 | 0 |
| 1723107799000 | 0 | None | None | Other Works | 2 Installation of Mini Highmast at wno 11 at Aland | 117349.89 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3724004 | 138076 | None | 001 | Fabricating, supplying and erection of ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s form Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom mm top mmwith 3 mm thick, suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc(excluding foundation) as per drawing appended. PWD Electricl SR 2023-24 It. No. 4.4 Pg. No. 12 of 105 | Each | 12700.0 | 12700.0 | 1.0 | False | None | None | False | None | False | 12700.0 | 0 | 3724005 | 138076 | None | 002 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Main | Each | 12490.0 | 12490.0 | 4.0 | False | None | None | False | None | False | 49960.0 | 0 | 3724006 | 138076 | None | 003 | Fixing halogen / metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. PWD Elect SR 2023-24 It. No. 13.5 Pg. No. 56 of 105
| Each | 162.0 | 162.0 | 4.0 | False | None | None | False | None | False | 648.0 | 0 | 3724007 | 138076 | None | 004 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 PWD Electrical SR 2023-24 It. No. 2.5.14 Pg. No. 6 of 105
| Each | 123.0 | 123.0 | 35.0 | False | None | None | False | None | False | 4305.0 | 0 | 3724008 | 138076 | None | 005 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified PWD Electrical SR It. No. 51.04 Sl. No. 392 Pg. No. 23/81
| No | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 | 3724009 | 138076 | None | 006 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. PWD Electrical SR 2023-24 It. No. 5.18.1 Pg. No. 17 of 105
| Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | 3724010 | 138076 | None | 007 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. PWD Electrical SR 2023-24 It. No. 5.35 Pg. No. 19 of 105
| Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | 3724011 | 138076 | None | 008 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - PWD SR 2023-24 It. No. 32.00 Sl. No. 32.05 Pg. No. 13/81 - 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)
| Km | 141842.0 | 141842.0 | 0.05 | False | None | None | False | None | False | 7092.1 | 0 | 3724012 | 138076 | None | 009 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25sqmm - PWD Electrical SR 2023-24 It. No. 21.05 Sl. No. 174 Pg. No. 51/81
| Km | 20886.0 | 20886.0 | 0.05 | False | None | None | False | None | False | 1044.3 | 0 | 3724013 | 138076 | None | 0010 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. PWD Electrical SR 2023-24 It. No. 5.48 Pg. No. 21 of 105
| Nos | 4843.0 | 4843.0 | 1.0 | False | None | None | False | None | False | 4843.0 | 0 | 3724014 | 138076 | None | 0011 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. PWD Electrical SR 2023-24 It. No. 5.44.1 Pg. No. 21 of 105 - 300 mm x 300 mm x 214 mm
| No | 4512.0 | 4512.0 | 1.0 | False | None | None | False | None | False | 4512.0 | 0 | 3724015 | 138076 | None | 0012 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. PWD Electrical SR 2023-24 It. No.5.14.3 Pg. No. 16 of 105 - 40A
| Nos | 6119.0 | 6119.0 | 1.0 | False | None | None | False | None | False | 6119.0 | 0 | 3724016 | 138076 | None | 0013 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount onDIN rail/ flush mounting on panel board. PWD Electrical SR 2023-24 It. No 5.21 Pg. No. 18/105
| No | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 | 3724017 | 138076 | None | 0014 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. PWD Electrical SR 2023-24 It. No. 5.38 Pg. No. 19/105
| Nos | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | 3724018 | 138076 | None | 0015 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. PWD SR 2023-24 It. No. 1.4.1 Pg. No. 5, Vol-1
| Cum | 254.1 | 254.1 | 6.64 | False | None | None | False | None | False | 1687.224 | 0 | 3724019 | 138076 | None | 0016 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. PWD SR 2022-23 It. No. 2.1.3 Pg. No. 15 Vol-1 Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 0.04 | False | None | None | False | None | False | 251.538 | 0 | 3724020 | 138076 | None | 0017 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. For all other type of structures - PWD SR 2023-24 It. No. 2.11(1) Pg. No. 18
| Tonne | 93929.85 | 93929.85 | 0.04 | False | None | None | False | None | False | 3757.194 | 0 | 3724021 | 138076 | None | 0018 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate PWD SR 2023-24 It. No. 16.27 Pg. No. 147 Vol-3
| Cum | 6692.7 | 6692.7 | 0.2 | False | None | None | False | None | False | 1338.54 | 0 |
|
|
---|