tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1723106799000 | 0 | None | None | Other Works | 1Construction of Compound Wall For Graveyard at W no 7 | 397959.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3723624 | 138052 | None | 001 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth PWD SR 2023-24 It. No. 1.5.1 Pg. No. 6 Vol-1
| Cum | 314.0 | 314.0 | 47.04 | False | None | None | False | None | False | 14770.56 | 0 | 3723625 | 138052 | None | 002 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2022-23 It. No. 2.1.4 Pg. No. 15 Vol-1
| Cum | 6528.0 | 6528.0 | 5.66 | False | None | None | False | None | False | 36948.48 | 0 | 3723626 | 138052 | None | 003 | Providing and laying in position reinforcement Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. PWD SR 2023-24 It. No. 2.5.1 Pg. No. 78 Vol-1
| Cum | 6962.0 | 6962.0 | 10.42 | False | None | None | False | None | False | 72544.04 | 0 | 3723627 | 138052 | None | 004 | Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement complete as per drawing and technical specification. - PWD SR 2023-24 It. No. 2.11(a) Pg. No. 3 Vol-1
| Tonne | 93930.0 | 93930.0 | 1.04 | False | None | None | False | None | False | 97687.2 | 0 | 3723628 | 138052 | None | 005 | Additional for Form work, Centering and Scaffolding, roof, column (Straight and arched) - PWD SR 2023-24 Pg. No. 115 It.No. 12 & 13 Vol-1 Add 50% for Centering
| Cum | 3481.0 | 3481.0 | 6.51 | False | None | None | False | None | False | 22661.31 | 0 | 3723629 | 138052 | None | 006 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR 2023-24 It. No. 6.1 Pg. No. 13 Vol-2
| Cum | 8622.0 | 8622.0 | 13.25 | False | None | None | False | None | False | 114241.5 | 0 | 3723630 | 138052 | None | 007 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 It. No.8.1.2 Pg. No. 41 Vol-2
| Sqm | 253.0 | 253.0 | 153.6 | False | None | None | False | None | False | 38860.8 | 0 | 3723631 | 138052 | None | 007 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 It. No. 8.25 Pg.No 45 Vol-2
| Sqm | 153.6 | 153.6 | 1.6 | False | None | None | False | None | False | 245.76 | 0 |
| 1723106799000 | 0 | None | None | Other Works | 2Construction of CC Road and RCC Drain in Shashank Layout in wno5 | 197893.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3723632 | 138053 | None | 001 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. PWD SR 2023-24 It. No. 3.7 Pg. No. 16 Vol 3
| Sqm | 110.0 | 110.0 | 27.0 | False | None | None | False | None | False | 2970.0 | 0 | 3723633 | 138053 | None | 002 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. PWD SR 2023-24 It.No.1.1 Pg.No.5 Vol-1
| Cum | 95.55 | 95.55 | 54.0 | False | None | None | False | None | False | 5159.7 | 0 | 3723634 | 138053 | None | 003 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. PWD SR 2023-24 It. No. 1.8 Pg. No.7 Vol-1
| Cum | 497.7 | 497.7 | 25.31 | False | None | None | False | None | False | 12596.787 | 0 | 3723635 | 138053 | None | 004 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 PWD SR 2023-24 It. No. 3.6 Pg. No. 16 Vol-3
| Sqm | 518.0 | 518.0 | 18.0 | False | None | None | False | None | False | 9324.0 | 0 | 3723636 | 138053 | None | 005 | Construction of dry lean cement concrete sub base over a prepared sub grade with coarse andfine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25mm aggregate cement ratio not to exceed 12:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3, optimum moisture content to be determined during trial length construction concrete strength not to be less than 7 Mpa at 7 days mixed in a batching plant transported to site, laid with a paer with electronic sensor compacting with 8-10 t vibratory roller finishing and curing - PWD SR 2023-24 It. No. 6.3 Pg. No. 49 Vol-3
| Cum | 4971.55 | 4971.55 | 16.88 | False | None | None | False | None | False | 83919.764 | 0 | 3723637 | 138053 | None | 006 | Construction of un reinforced plain cement concrete paement using RMC M-30 grade with OPC at 270 kg/ m3 and GGBS @ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared su base. The superplasticiser conforming to IS 9103-1999 reaffirmed-2008 coarse aggregates and fine aggregate conforming to IS 383-2016, transported to site, laid in apprved fixed side form work (steel channel laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work spreading the concrete with shovels, rackers and compacted using needle, suitale plate vibrator and finished in a contineous operation including provision of seperation membrane and Hessian cloth finishing to lines and grades complete including cost of al materials labour all lead and lift loading charges as per specification and direction of Engineer incharge of the work - PWD SR 2023-24 It. No. 6.6 Pg. No. 51 Vol-3
| Cum | 4971.75 | 4971.75 | 16.88 | False | None | None | False | None | False | 83923.14 | 0 |
| 1723106799000 | 0 | None | None | Other Works | 3Installation of LED Bulbs For Street Light at wno 7 | 341412.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3723638 | 138054 | None | 001 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ misswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI any Government certified agency Design & Development facility certified by ISO Housing with supplier word mark /name shall be Engraved Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer Cree Nichia Lumileds/Osram make LED Source | No | 5992.0 | 5992.0 | 39.0 | False | None | None | False | None | False | 233688.0 | 0 | 3723639 | 138054 | None | 002 | Fixing halogen / metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. PWD Elect SR 2023-24 It. No. 13.5 Pg. No. 56 of 105
| No | 162.0 | 162.0 | 39.0 | False | None | None | False | None | False | 6318.0 | 0 | 3723640 | 138054 | None | 003 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 PWD Electrical SR 2023-24 It. No. 2.5.14 Pg. No. 6 of 105 | m | 123.0 | 123.0 | 300.0 | False | None | None | False | None | False | 36900.0 | 0 | 3723641 | 138054 | None | 004 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. PWD Electrical SR 2023-24 It. No. 13.1.1 Pg. No. 56 of 105
| Each | 978.0 | 978.0 | 39.0 | False | None | None | False | None | False | 38142.0 | 0 | 3723642 | 138054 | None | 005 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. PWD Electrical SR 2023-24 It. No. 5.18.1 Pg. No. 17 of 105
| Each | 415.0 | 415.0 | 39.0 | False | None | None | False | None | False | 16185.0 | 0 | 3723643 | 138054 | None | 006 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. PWD Electrical SR 2023-24 It. No. 3.3.6 Pg. No. 8 of 105
| Each | 261.0 | 261.0 | 39.0 | False | None | None | False | None | False | 10179.0 | 0 |
|
|
---|