3727435 | 138358 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m Vol-1 (pg no 8, I No 1.14.1) | Cum | 105.06 | 105.06 | 673.728 | False | None | None | False | None | False | 70781.86368 | 0 |
3727436 | 138358 | None | code02 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Vol-2 (pg no 5, I No 4.1) | Sqm | 121.54 | 121.54 | 113.4 | False | None | None | False | None | False | 13782.636 | 0 |
3727437 | 138358 | None | code03 | Providing and laying in position Cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 15, I No 2.1.3) | Cum | 6168.67 | 6168.67 | 31.26 | False | None | None | False | None | False | 192832.6242 | 0 |
3727438 | 138358 | None | code04 | Providing and Filling in foundation with granite/trap broken metal 1OOmm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. Vol-1 (pg no 11, I No 1..23) | Cum | 2762.46 | 2762.46 | 18.38 | False | None | None | False | None | False | 50774.0148 | 0 |
3727439 | 138358 | None | code05 | Providing and laying in position Cement concrete for all Foundation works. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated As per Addendum-I in Volume-1 of page No.-111 (@8% of Finished Rate) Vol-1 (pg no 15, I No 2.2.3) | Cum | 7048.17 | 7048.17 | 37.58 | False | None | None | False | None | False | 264870.2286 | 0 |
3727440 | 138358 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 9: RCC Columns As per Addendum-I in Volume-1 of page No.-111 (@70% of Finished Rate) Vol-1 (pg no 16, I No 2.4.3) | Cum | 11094.34 | 11094.34 | 2.56 | False | None | None | False | None | False | 28401.5104 | 0 |
3727441 | 138358 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 11: Earth retaining structures As per Addendum-I in Volume-1 of page No.-112 (@10% of Finished Rate) Vol-1 (pg no 16, I No 2.4.3) | Cum | 7178.69 | 7178.69 | 11.03 | False | None | None | False | None | False | 79180.9507 | 0 |
3727442 | 138358 | None | code08 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol-1 (pg no 7, I No 1.11) | Cum | 445.99 | 445.99 | 668.91 | False | None | None | False | None | False | 298327.1709 | 0 |
3727443 | 138358 | None | code09 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 9 : RCC Columns As per Addendum-I in Volume-1 of page No.-111 (@70% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 11982.09 | 11982.09 | 5.7 | False | None | None | False | None | False | 68297.913 | 0 |
3727444 | 138358 | None | code10 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 1.a Plinth beam of buildings As per Addendum-I in Volume-1 of page No.-111 (@50% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 10572.44 | 10572.44 | 5.83 | False | None | None | False | None | False | 61637.3252 | 0 |
3727445 | 138358 | None | code11 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 14 : beam & lintels of buildings As per Addendum-I in Volume-1 of page No.-112 (@60% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 11277.26 | 11277.26 | 7.48 | False | None | None | False | None | False | 84353.9048 | 0 |
3727446 | 138358 | None | code12 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 19 : Chejjas, Canopy & Other Architectural projections of minor sections As per Addendum-I in Volume-1 of page No.-112 (@45% of Finished Rate)Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 10220.02 | 10220.02 | 0.76 | False | None | None | False | None | False | 7767.2152 | 0 |
3727447 | 138358 | None | code13 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 15 : Roof slab of Buildings As per Addendum-I in Volume-1 of page No.-112 (@50% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 10572.44 | 10572.44 | 20.34 | False | None | None | False | None | False | 215043.4296 | 0 |
3727448 | 138358 | None | code14 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a. Buildings Vol-1 (pg no 18, I No 2.11(a)) | Tonne | 92140.71 | 92140.71 | 8.75 | False | None | None | False | None | False | 806231.2125 | 0 |
3727449 | 138358 | None | code15 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Vol-2 (pg no 17, I No 6.32) | Sqm | 1349.3 | 1349.3 | 135.48 | False | None | None | False | None | False | 182803.164 | 0 |
3727450 | 138358 | None | code16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Vol-2 (pg no 17, I No 6.32) First Floor | Sqm | 1362.79 | 1362.79 | 82.41 | False | None | None | False | None | False | 112307.5239 | 0 |
3727451 | 138358 | None | code17 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. y) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 16, I No 2.4.1) | Cum | 6596.12 | 6596.12 | 0.89 | False | None | None | False | None | False | 5870.5468 | 0 |
3727452 | 138358 | None | code18 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. y) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 16, I No 2.4.1) First Floor | Cum | 6662.08 | 6662.08 | 0.98 | False | None | None | False | None | False | 6528.8384 | 0 |
3727453 | 138358 | None | code19 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) | Sqm | 262.65 | 262.65 | 116.22 | False | None | None | False | None | False | 30525.183 | 0 |
3727454 | 138358 | None | code20 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) | Sqm | 303.85 | 303.85 | 206.73 | False | None | None | False | None | False | 62814.9105 | 0 |
3727455 | 138358 | None | code21 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) First Floor | Sqm | 306.89 | 306.89 | 51.14 | False | None | None | False | None | False | 15694.3546 | 0 |
3727456 | 138358 | None | code22 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Vol-2 (pg no 42, I No 8.8) | Sqm | 382.13 | 382.13 | 197.88 | False | None | None | False | None | False | 75615.8844 | 0 |
3727457 | 138358 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Vol-2 (pg no 42, I No 8.8) First Floor | Sqm | 385.95 | 385.95 | 137.66 | False | None | None | False | None | False | 53129.877 | 0 |
3727458 | 138358 | None | code24 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. Vol-2 (pg no 54, I No 8.80) | m | 67.98 | 67.98 | 109.6 | False | None | None | False | None | False | 7450.608 | 0 |
3727459 | 138358 | None | code25 | Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services,junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications(length of mesh only be measured for payment) Vol-2 (pg no 43, I No 8.16.2) | m | 39.14 | 39.14 | 228.8 | False | None | None | False | None | False | 8955.232 | 0 |
3727460 | 138358 | None | code26 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications Vol-2 (pg no 44, I No 8.16 a) | Sqm | 1275.14 | 1275.14 | 3.78 | False | None | None | False | None | False | 4820.0292 | 0 |
3727461 | 138358 | None | code27 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Vol-2 (pg no 61, I No 9.17.2) | Sqm | 1210.25 | 1210.25 | 57.0 | False | None | None | False | None | False | 68984.25 | 0 |
3727462 | 138358 | None | code28 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Vol-2 (pg no 63, I No 9.24) | Sqm | 2937.56 | 2937.56 | 90.55 | False | None | None | False | None | False | 265996.058 | 0 |
3727463 | 138358 | None | code29 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge Vol-2 (pg no 69, I No 10.2) | m | 337.84 | 337.84 | 69.6 | False | None | None | False | None | False | 23513.664 | 0 |
3727464 | 138358 | None | code30 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Vol-2 (pg no 100, I No 12.13.1) | Cum | 101779.45 | 101779.45 | 0.19 | False | None | None | False | None | False | 19338.0955 | 0 |
3727465 | 138358 | None | code31 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Vol-2 (pg no 104, I No 12.51) | Nos | 1046.48 | 1046.48 | 2.0 | False | None | None | False | None | False | 2092.96 | 0 |
3727466 | 138358 | None | code32 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Vol-2 (pg no 105, I No 12.57.6) | Sqm | 3421.66 | 3421.66 | 4.77 | False | None | None | False | None | False | 16321.3182 | 0 |
3727467 | 138358 | None | code33 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 110, I No 12.88) | Sqm | 5551.7 | 5551.7 | 8.1 | False | None | None | False | None | False | 44968.77 | 0 |
3727468 | 138358 | None | code34 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 109, I No 12.85) | Sqm | 5890.57 | 5890.57 | 3.24 | False | None | None | False | None | False | 19085.4468 | 0 |
3727469 | 138358 | None | code35 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Vol-2 (pg no 86, I No 11.34B) | Kg | 188.49 | 188.49 | 238.14 | False | None | None | False | None | False | 44887.0086 | 0 |
3727470 | 138358 | None | code36 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-2 (pg no 50 I No 8.51) | Sqm | 103.0 | 103.0 | 322.95 | False | None | None | False | None | False | 33263.85 | 0 |
3727471 | 138358 | None | code37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-2 (pg no 50 I No 8.51) First Floor | Sqm | 104.03 | 104.03 | 51.14 | False | None | None | False | None | False | 5320.0942 | 0 |
3727472 | 138358 | None | code38 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). Vol-2 (pg no 46, I No 8.33.1) | Sqm | 162.74 | 162.74 | 322.95 | False | None | None | False | None | False | 52556.883 | 0 |
3727473 | 138358 | None | code39 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). Vol-2 (pg no 46, I No 8.33.1) First Floor | Sqm | 164.37 | 164.37 | 51.14 | False | None | None | False | None | False | 8405.8818 | 0 |
3727474 | 138358 | None | code40 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) | Sqm | 160.68 | 160.68 | 197.88 | False | None | None | False | None | False | 31795.3584 | 0 |
3727475 | 138358 | None | code41 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) First Floor | Sqm | 162.29 | 162.29 | 137.66 | False | None | None | False | None | False | 22340.8414 | 0 |
3727476 | 138358 | None | code42 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.33.2) | Sqm | 142.14 | 142.14 | 6.55 | False | None | None | False | None | False | 931.017 | 0 |
3727477 | 138358 | None | code43 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 47, I No 8.33.3) | Sqm | 143.17 | 143.17 | 11.34 | False | None | None | False | None | False | 1623.5478 | 0 |
3727478 | 138358 | None | code44 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 85, I No 11.28) | Kg | 581.95 | 581.95 | 96.0 | False | None | None | False | None | False | 55867.2 | 0 |
3727479 | 138358 | None | code45 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm . Vol-2 (pg no 107, I No 12.74.1) | Nos | 105.06 | 105.06 | 11.0 | False | None | None | False | None | False | 1155.66 | 0 |
3727480 | 138358 | None | code46 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Vol-2 (pg no 108, I No 12.60) | Nos | 1083.56 | 1083.56 | 2.0 | False | None | None | False | None | False | 2167.12 | 0 |
3727481 | 138358 | None | code47 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 250x10mm Vol-2 (pg no 218, I No 22.15.7) | Nos | 206.0 | 206.0 | 3.0 | False | None | None | False | None | False | 618.0 | 0 |
3727482 | 138358 | None | code48 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 300mm Vol-2 (pg no 218, I No 22.15.4) | Nos | 386.25 | 386.25 | 4.0 | False | None | None | False | None | False | 1545.0 | 0 |
3727483 | 138358 | None | code49 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 200mm length Vol-2 (pg no 218, I No 22.15.3) | Nos | 1545.0 | 1545.0 | 3.0 | False | None | None | False | None | False | 4635.0 | 0 |
3727484 | 138358 | None | code50 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Door Stopper 75mm Vol-2 (pg no 218, I No 22.15.10) | Nos | 103.0 | 103.0 | 3.0 | False | None | None | False | None | False | 309.0 | 0 |
3727485 | 138358 | None | code51 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. Vol-2 (pg no 55, I No 8.84) | Sqm | 489.25 | 489.25 | 2.88 | False | None | None | False | None | False | 1409.04 | 0 |
3727486 | 138358 | None | code52 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 82, I No 11.16.1) | Kg | 141.48 | 141.48 | 98.06 | False | None | None | False | None | False | 13873.5288 | 0 |
3727487 | 138358 | None | code53 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Vol-2 (pg no 26, I No 7.38) | Sqm | 590.89 | 590.89 | 28.9 | False | None | None | False | None | False | 17076.721 | 0 |
3727488 | 138358 | None | code54 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring confirming to IS : 5383, leaving 10mm gap for termal expansion (i) single socketed pepes 100mm diameter Vol-2 (pg no 125, I No 13.48) | m | 299.73 | 299.73 | 12.0 | False | None | None | False | None | False | 3596.76 | 0 |
3727489 | 138358 | None | code55 | Concealed conduit system :supplying heavy guage PVC conduit pipe confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary a) 19/20mm dia 2mm thick | Mtr | 67.98 | 67.98 | 80.0 | False | None | None | False | None | False | 5438.4 | 0 |
3727490 | 138358 | None | code56 | Concealed conduit system :supplying heavy guage PVC conduit pipe confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary b) 25mm dia 2mm thick | Mtr | 80.34 | 80.34 | 60.0 | False | None | None | False | None | False | 4820.4 | 0 |
3727491 | 138358 | None | code57 | Groove cutting : supplying heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. a) 19/20mm dia 2mm thick | Mtr | 70.04 | 70.04 | 30.0 | False | None | None | False | None | False | 2101.2 | 0 |
3727492 | 138358 | None | code58 | Groove cutting : supplying heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. b) 25mm dia 2mm thick | Mtr | 81.37 | 81.37 | 20.0 | False | None | None | False | None | False | 1627.4 | 0 |
3727493 | 138358 | None | code59 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to outlet via switch box | Point | 277.07 | 277.07 | 2.0 | False | None | None | False | None | False | 554.14 | 0 |
3727494 | 138358 | None | code60 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
medium point above 3Mtr upto 6Mtr from tapping point outlet via switch box | Point | 390.37 | 390.37 | 10.0 | False | None | None | False | None | False | 3903.7 | 0 |
3727495 | 138358 | None | code61 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
long point above 6Mtr upto 10Mtr tapping point to outlet via switch box | Point | 571.65 | 571.65 | 10.0 | False | None | None | False | None | False | 5716.5 | 0 |
3727496 | 138358 | None | code62 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 1-2 way | Each | 142.14 | 142.14 | 2.0 | False | None | None | False | None | False | 284.28 | 0 |
3727497 | 138358 | None | code63 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 4-5 way | Each | 182.31 | 182.31 | 2.0 | False | None | None | False | None | False | 364.62 | 0 |
3727498 | 138358 | None | code64 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 8 way | Each | 268.83 | 268.83 | 1.0 | False | None | None | False | None | False | 268.83 | 0 |
3727499 | 138358 | None | code65 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 10-12 way | Each | 328.57 | 328.57 | 2.0 | False | None | None | False | None | False | 657.14 | 0 |
3727500 | 138358 | None | code66 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 16 way | Each | 373.89 | 373.89 | 1.0 | False | None | None | False | None | False | 373.89 | 0 |
3727501 | 138358 | None | code67 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 1to 2 module | Each | 141.11 | 141.11 | 2.0 | False | None | None | False | None | False | 282.22 | 0 |
3727502 | 138358 | None | code68 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 4 module | Each | 180.25 | 180.25 | 2.0 | False | None | None | False | None | False | 360.5 | 0 |
3727503 | 138358 | None | code69 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 8 module | Each | 292.52 | 292.52 | 1.0 | False | None | None | False | None | False | 292.52 | 0 |
3727504 | 138358 | None | code70 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 12 module | Each | 354.32 | 354.32 | 2.0 | False | None | None | False | None | False | 708.64 | 0 |
3727505 | 138358 | None | code71 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 16 Module | Each | 408.91 | 408.91 | 1.0 | False | None | None | False | None | False | 408.91 | 0 |
3727506 | 138358 | None | code72 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6 Amps one way switch | Each | 105.06 | 105.06 | 30.0 | False | None | None | False | None | False | 3151.8 | 0 |
3727507 | 138358 | None | code73 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 2 way switch | Each | 170.98 | 170.98 | 1.0 | False | None | None | False | None | False | 170.98 | 0 |
3727508 | 138358 | None | code74 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3 way socket | Each | 176.13 | 176.13 | 6.0 | False | None | None | False | None | False | 1056.78 | 0 |
3727509 | 138358 | None | code75 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator two module | Each | 367.71 | 367.71 | 4.0 | False | None | None | False | None | False | 1470.84 | 0 |
3727510 | 138358 | None | code76 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps 1 way switch | Each | 185.4 | 185.4 | 2.0 | False | None | None | False | None | False | 370.8 | 0 |
3727511 | 138358 | None | code77 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch | Each | 335.78 | 335.78 | 1.0 | False | None | None | False | None | False | 335.78 | 0 |
3727512 | 138358 | None | code78 | Supplying and fixing of modular switch & connected accessories on existing moular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket | Each | 243.08 | 243.08 | 2.0 | False | None | None | False | None | False | 486.16 | 0 |
3727513 | 138358 | None | code79 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 1.5 Sqmm | m | 26.78 | 26.78 | 250.0 | False | None | None | False | None | False | 6695.0 | 0 |
3727514 | 138358 | None | code80 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 2.5 Sqmm | m | 43.26 | 43.26 | 500.0 | False | None | None | False | None | False | 21630.0 | 0 |
3727515 | 138358 | None | code81 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 4 Sqmm | m | 64.89 | 64.89 | 100.0 | False | None | None | False | None | False | 6489.0 | 0 |
3727516 | 138358 | None | code82 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 6 Sqmm | m | 94.76 | 94.76 | 150.0 | False | None | None | False | None | False | 14214.0 | 0 |
3727517 | 138358 | None | code83 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.III - Double Door 6Way TP &N | Each | 5088.2 | 5088.2 | 1.0 | False | None | None | False | None | False | 5088.2 | 0 |
3727518 | 138358 | None | code84 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SP | Each | 427.45 | 427.45 | 4.0 | False | None | None | False | None | False | 1709.8 | 0 |
3727519 | 138358 | None | code85 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps DP | Each | 761.17 | 761.17 | 2.0 | False | None | None | False | None | False | 1522.34 | 0 |
3727520 | 138358 | None | code86 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.. 63 Amps 4 pole | Each | 5711.35 | 5711.35 | 1.0 | False | None | None | False | None | False | 5711.35 | 0 |
3727521 | 138358 | None | code87 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Nos | 3615.3 | 3615.3 | 1.0 | False | None | None | False | None | False | 3615.3 | 0 |
3727522 | 138358 | None | code88 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI Strip | Mtr | 131.84 | 131.84 | 25.0 | False | None | None | False | None | False | 3296.0 | 0 |
3727523 | 138358 | None | code89 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper Strip | Mtr | 587.1 | 587.1 | 25.0 | False | None | None | False | None | False | 14677.5 | 0 |
3727524 | 138358 | None | code90 | Supplying of PVC Batten with integrated LED tube LED light fighting 1 x4' 36/40 w with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 1307.07 | 1307.07 | 14.0 | False | None | None | False | None | False | 18298.98 | 0 |
3727525 | 138358 | None | code91 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size 110mm conduite using necessary machine screws. | No | 21.63 | 21.63 | 50.0 | False | None | None | False | None | False | 1081.5 | 0 |
3727526 | 138358 | None | code92 | Supplying & Fixing of 230 Volts 20/40 watts Fluorescent
Lamp holder | No | 33.99 | 33.99 | 50.0 | False | None | None | False | None | False | 1699.5 | 0 |
3727527 | 138358 | None | code93 | Supplying and fixing Metal Fan Box with Round Hook | No | 120.51 | 120.51 | 4.0 | False | None | None | False | None | False | 482.04 | 0 |
3727528 | 138358 | None | code94 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 3073.52 | 3073.52 | 4.0 | False | None | None | False | None | False | 12294.08 | 0 |
3727529 | 138358 | None | code95 | Fixing all types and all capacities fluorecent/false ceiling/spot light/CFL fittings indoor on the wall / rafter / girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required)a)On wall/ceiling/Rafters/Girders | Each | 125.66 | 125.66 | 14.0 | False | None | None | False | None | False | 1759.24 | 0 |
3727530 | 138358 | None | code96 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing S hook together with supplying and fixing a 5 amperes ceiling rose,necessary lenth of 23/0.0076 inch PVC insluted twisted copper wire and wiring completely. | Each | 176.13 | 176.13 | 4.0 | False | None | None | False | None | False | 704.52 | 0 |