createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723209181703
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd12500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose17-08-2024 17:00:00
tenderQueryClose12-08-2024 15:00:00
technicalBidOpenNone
publishedDate10-08-2024 12:21:23
publishedByPostKKRTC_EE_HOFF_BLR
publishedByUserKPE10109 - M ERESH
bidValidityPeriod90
noOfCalls2
preBidMeetingDate14-08-2024 12:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonSri.M.Eresh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber8392294828
mobileNumber9972039797
tenderSupplierListNone
tenderSchedule
createdTs1723209181705
version14
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/BD/WORK_INDENT79/CALL-2
titleConstruction of water recycling plant (E.T.P) for Bus Depot at Gangavathi (Koppal Division)
descriptionConstruction of water recycling plant (E.T.P) for Bus Depot at Gangavathi (Koppal Division)
categoryWORKS
categoryTextWorks
ecv499999.98
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5937
locationNameKKRTC Divisional Controller Office Bellari
provisionalAmount500000.0
groupOverheadTotal1857.88
fileNumber00040
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17232091820001NoneNoneBuildingsConstruction of water recycling plant (E.T.P) for Bus Depot at Gangavathi (Koppal Division)498142.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3740737139491Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) In all kinds of soils Depth upto 3 mCum90.4490.4448.96FalseNoneNoneFalseNoneFalse4427.94240
3740738139491Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum6450.236450.233.33FalseNoneNoneFalseNoneFalse21479.26590
3740739139491Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7952.447952.442.08FalseNoneNoneFalseNoneFalse16541.07520
3740740139491Nonecode04Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11489.2411489.248.4FalseNoneNoneFalseNoneFalse96509.6160
3740741139491Nonecode05SR 2018-19 SRP 15/4.19 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.5175cum and fine aggregtes @ 0.345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications. Specification No. KBS 4.1, 4.6Sqm516.84516.8411.34FalseNoneNoneFalseNoneFalse5860.96560
3740742139491Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12255.1912255.190.31FalseNoneNoneFalseNoneFalse3799.10890
3740743139491Nonecode07Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2)Sqm284.97284.9731.71FalseNoneNoneFalseNoneFalse9036.39870
3740744139491Nonecode08Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-II (84/11.32) As per 4th QTRKg113.98113.981161.45FalseNoneNoneFalseNoneFalse132382.0710
3740745139491Nonecode09Providing & filling Quartz Sand (in Sand filter Media) including filling etc., complete SRP II/60/ 0781Cum12.9812.982148.12FalseNoneNoneFalseNoneFalse27882.59760
3740746139491Nonecode10Providing & Filling activated carbon as filter media in Setling tankCum44.8444.84537.03FalseNoneNoneFalseNoneFalse24080.42520
3740747139491Nonecode11Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Apex Paint) SRP- Vol-II (45/8.28)Sqm81.7781.7750.0FalseNoneNoneFalseNoneFalse4088.50
3740748139491Nonecode12Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (11/13.33.6)Mtr581.09581.0910.0FalseNoneNoneFalseNoneFalse5810.90
3740749139491Nonecode13Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (11/13.33.6)Mtr370.46370.4650.0FalseNoneNoneFalseNoneFalse18523.00
3740750139491Nonecode14Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/34A)Kg179.65179.6537.8FalseNoneNoneFalseNoneFalse6790.770
3740751139491Nonecode15Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 187/8/T130AEach5419.385419.382.0FalseNoneNoneFalseNoneFalse10838.760
3740752139491Nonecode16Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.7)Rmtr488.16488.1612.0FalseNoneNoneFalseNoneFalse5857.920
3740753139491Nonecode17Providing and placing on terrace polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet uolet and over flow pipes includng cost of ll materials, labour transport charges HOM of equipments and testing complete as per specification VOL II SRP 13.34A (For 1000 ltr capacity)Rmtr9.919.914000.0FalseNoneNoneFalseNoneFalse39640.00
3740754139491Nonecode18Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.9)Rmtr742.16742.1630.0FalseNoneNoneFalseNoneFalse22264.80
3740755139491Nonecode19Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground SRP- Vol-I (A-45/50)Hour1169.611169.616.0FalseNoneNoneFalseNoneFalse7017.660
3740756139491Nonecode20Supplying of single phase self priming 1HP/0.75KW 50Hz bronze impeller, alluminium body, cast iron mounting monoblock pump for circulation of water in industries Civil SR 2018-19/XLV/2No10550.3810550.381.0FalseNoneNoneFalseNoneFalse10550.380
3740757139491Nonecode21Elect SR 2022-23/4/2.6.3 Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990Mtr197.06197.0650.0FalseNoneNoneFalseNoneFalse9853.00
3740758139491Nonecode22Supply, delivery, erection and commissioning at site lighting distribution board suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments.Civil SR 21-22/165/50/P480ANo5310.05310.01.0FalseNoneNoneFalseNoneFalse5310.00
3740759139491Nonecode23Electrical SR 2022-23/1/1.1.1 Open Conduit System Supplying heavy gauge PVC conduit pipe 25mm.dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr94.494.441.0FalseNoneNoneFalseNoneFalse3870.40
3740760139491Nonecode24Elect SR 2022-23/13/5.17.4 Supplying and fixing 32A DP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and omplete wiring as required confirming to IEC 60898No1301.541301.541.0FalseNoneNoneFalseNoneFalse1301.540
3740761139491Nonecode25Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Civil SR 2021-22/Vol-5/164/45/P430ANo4425.04425.01.0FalseNoneNoneFalseNoneFalse4425.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17232091820000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17232091820000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17232091820000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17232091820000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17232091820000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17232091820000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17232091820000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17232091820000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17232091820000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17232091820000NoneNoneELIGIBILITYBanker DetailsNone
17232091820000NoneNoneELIGIBILITYEstimated Rates inclusive of all applicable taxes including GST.None
17232091820000NoneNoneELIGIBILITYThe bidder shall quote their rates inclusive of all applicable taxes and inclusive of GST.None
17232091820000NoneNoneELIGIBILITYGST will not be paid separately. It is added in the individual items rates.None
17232091820000NoneNoneELIGIBILITYTERMS AND CONDITIONS AS PER TENDER NOTIFICATIONNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Upload a Scanned copy of attested Valid contractors Registration Certificate as per tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of work done one work of similar nature / Building as per tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of Annual Financial Turnover audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of self declaration certificate as per tender notification Eligibility CriteriaFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1723272511000
version0
createdDateNone
modifiedDateNone
blockNumberNear SP Circle Ballari
streetNone
cityBallari
stateKarnataka
pin583102
tenderRecallDTONone