1723209028000 | 0 | None | None | Other Works | Construction of processing shed in Solid Waste Management Site | 2302329.53 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3740699 | 139489 | None | code01 | Earth work excavation for foundation of structure upto 3 mtSD. By mechanicle means as per drawing and technical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., complete Ordinary/Hard Soil. In all kinds of soils Depth upto 3 m (PWD SR Vol-01, 2023-24, Item no. 2.1.4, Page No.15) | Cum | 105.06 | 105.06 | 26.46 | False | None | None | False | None | False | 2779.8876 | 0 | 3740700 | 139489 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (PWD SR Vol-01, 2023-24, Item no. 2.1.4, Page No.15) | Cum | 6403.51 | 6403.51 | 2.66 | False | None | None | False | None | False | 17033.3366 | 0 | 3740701 | 139489 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR Vol-02, 2023-24, Item no.5.1.1, Page No.9) | Cum | 5779.33 | 5779.33 | 13.5 | False | None | None | False | None | False | 78020.955 | 0 | 3740702 | 139489 | None | code04 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 ( PWD SR 2023-24 Vol-3 , P.No -17 ,I No - 3.6 ) | Cum | 507.79 | 507.79 | 270.0 | False | None | None | False | None | False | 137103.3 | 0 | 3740703 | 139489 | None | code05 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 8463.86 | 8463.86 | 4.32 | False | None | None | False | None | False | 36563.8752 | 0 | 3740704 | 139489 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 8217.34 | 8217.34 | 31.5 | False | None | None | False | None | False | 258846.21 | 0 | 3740705 | 139489 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 13969.48 | 13969.48 | 8.32 | False | None | None | False | None | False | 116226.0736 | 0 | 3740706 | 139489 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.41, Page No.16) | Cum | 13147.74 | 13147.74 | 5.73 | False | None | None | False | None | False | 75336.5502 | 0 | 3740707 | 139489 | None | code09 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (PWD SR 2023-24, Vol-1 , Item No. 2.11a, Page No. 18) | Tonne | 92140.71 | 92140.71 | 2.958 | False | None | None | False | None | False | 272552.22018 | 0 | 3740708 | 139489 | None | code10 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR 2023-24, Vol-02, Item no. 11.16.1 Page No.81) | Kg | 140.08 | 140.08 | 7593.3 | False | None | None | False | None | False | 1063669.464 | 0 | 3740709 | 139489 | None | code11 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ) (PWD SR 2023-24, Vol-02, Item no. 7.38, Page No.26) | Sqm | 585.04 | 585.04 | 352.5 | False | None | None | False | None | False | 206226.6 | 0 | 3740710 | 139489 | None | code12 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18
microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) (PWD SR 2023-24, Vol-02, Item no. 7.39.1, Page No.27) | Mtr | 464.53 | 464.53 | 15.0 | False | None | None | False | None | False | 6967.95 | 0 | 3740711 | 139489 | None | code13 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24, Vol-02, Item no. 8.40, Page No.48) | Sqm | 118.45 | 118.45 | 261.74 | False | None | None | False | None | False | 31003.103 | 0 |
|