3745112 | 139915 | None | code01 | Demolishing R.C.C. work manually/ by mechanical means including stacking ofsteel bars and disposal of unserviceable material to theappropriate disposal area as per direction of Engineer-in-charge. Vol - 2 P-187/19.3 | Cum | 2668.6 | 2668.6 | 8.72 | False | None | None | False | None | False | 23270.192 | 0 |
3745113 | 139915 | None | code02 | Earth work excavation for Foundation by mechanical means for allworks &depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling theexcavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work vol - 1. P - 8/1.14.1 | Cum | 112.2 | 112.2 | 132.525 | False | None | None | False | None | False | 14869.305 | 0 |
3745114 | 139915 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarseaggregates, vol - 1 P - 15/2.1.2 | Cum | 6230.4 | 6230.4 | 23.058 | False | None | None | False | None | False | 143660.5632 | 0 |
3745115 | 139915 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse vol - 1 P- 15/2.2.2.1 | Cum | 7527.16 | 7527.16 | 25.29 | False | None | None | False | None | False | 190361.8764 | 0 |
3745116 | 139915 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Vol-1 P-15/2.2.1 | Cum | 11065.12 | 11065.12 | 10.16 | False | None | None | False | None | False | 112421.6192 | 0 |
3745117 | 139915 | None | code06 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.m2 1,310.00Vol - 02 P-17/6.32 | Sqm | 1441.0 | 1441.0 | 150.02 | False | None | None | False | None | False | 216178.82 | 0 |
3745118 | 139915 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse vol - | Cum | 10454.4 | 10454.4 | 32.44 | False | None | None | False | None | False | 339140.736 | 0 |
3745119 | 139915 | None | code08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Vol - 1,P-15/2.2.1 | Cum | 10027.76 | 10027.76 | 2.268 | False | None | None | False | None | False | 22742.95968 | 0 |
3745120 | 139915 | None | code 09 | Providing Thermo-Mechanically Treated bars of grade Fe-550D ormore Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (Thelaps and wastages shall not be measured separately) | Quintal | 9840.27 | 9840.27 | 56.78 | False | None | None | False | None | False | 558730.5306 | 0 |
3745121 | 139915 | None | code10 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification..Vol - 2,P-148/15.1 | Sqm | 898.7 | 898.7 | 93.6 | False | None | None | False | None | False | 84118.32 | 0 |
3745122 | 139915 | None | code11 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Vol-02 P-99/12.11 | Cum | 151881.4 | 151881.4 | 0.11 | False | None | None | False | None | False | 16706.954 | 0 |
3745123 | 139915 | None | code12 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial. Vol-02 P-106/12.57.3 | Sqm | 3305.5 | 3305.5 | 4.2 | False | None | None | False | None | False | 13883.1 | 0 |
3745124 | 139915 | None | code13 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam | Sqm | 2602.6 | 2602.6 | 10.8 | False | None | None | False | None | False | 28108.08 | 0 |
3745125 | 139915 | None | code14 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Vol-02 P-104/12.54. | Mtr | 349.8 | 349.8 | 30.0 | False | None | None | False | None | False | 10494.0 | 0 |
3745126 | 139915 | None | code15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. Vol-02 P-85/11.34A | Kg | 184.8 | 184.8 | 398.16 | False | None | None | False | None | False | 73579.968 | 0 |
3745127 | 139915 | None | code16 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) tobrick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Vol-02 P-41/8.3.2 | Sqm | 366.3 | 366.3 | 218.6 | False | None | None | False | None | False | 80073.18 | 0 |
3745128 | 139915 | None | code17 | 8.7 Providing 15 mm cement plaster with cement mortar 1:3 (1 Cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m2 321.00 Vol-02 P-42/8.7 | Sqm | 402.6 | 402.6 | 202.23 | False | None | None | False | None | False | 81417.798 | 0 |
3745129 | 139915 | None | code18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Vol-02 P-50/8.51 | Sqm | 110.0 | 110.0 | 202.23 | False | None | None | False | None | False | 22245.3 | 0 |
3745130 | 139915 | None | code19 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Vol-02 P-47/8.35.2 | Sqm | 217.8 | 217.8 | 202.23 | False | None | None | False | None | False | 44045.694 | 0 |
3745131 | 139915 | None | code20 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.P-47/8.3. of Vol - 2 | Sqm | 191.4 | 191.4 | 218.6 | False | None | None | False | None | False | 41840.04 | 0 |
3745132 | 139915 | None | code21 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) P- 110/12.90 of vol 2 | Sqm | 7407.4 | 7407.4 | 18.96 | False | None | None | False | None | False | 140444.304 | 0 |
3745133 | 139915 | None | code22 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with ement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and olishing etc. all complete as specified and as directed by the Engineer-in- harge ** Polished Granite stone slab Black, Cherry Red, Brown, Cat eye, River Pink or equivalent.Vol-02 P-63/9.24 | Sqm | 3137.2 | 3137.2 | 42.3 | False | None | None | False | None | False | 132703.56 | 0 |
3745134 | 139915 | None | code23 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. completeSize of Tile 600x600 mm.Vol-02 P-61/9.17.2. | Sqm | 1292.5 | 1292.5 | 52.44 | False | None | None | False | None | False | 67778.7 | 0 |
3745135 | 139915 | None | code24 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.m2 1,106.00 Vol-02 P-60/9.10 | Sqm | 1216.6 | 1216.6 | 13.05 | False | None | None | False | None | False | 15876.63 | 0 |
3745136 | 139915 | None | code25 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. P -65/9.39 | Sqm | 1593.9 | 1593.9 | 118.44 | False | None | None | False | None | False | 188781.516 | 0 |
3745137 | 139915 | None | code26 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 14.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern each 6,628.00 Vol-02 P- 124/14.5.1 | No | 9506.2 | 9506.2 | 3.0 | False | None | None | False | None | False | 28518.6 | 0 |
3745138 | 139915 | None | code27 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Vol- 2 P-123/14.1.1. | No | 5372.4 | 5372.4 | 3.0 | False | None | None | False | None | False | 16117.2 | 0 |
3745139 | 139915 | None | code28 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : vol- 2 P-131/14.2.2 | No | 5318.5 | 5318.5 | 1.0 | False | None | None | False | None | False | 5318.5 | 0 |
3745140 | 139915 | None | code29 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Vol- 2 P-132/14.7.2. | No | 2817.1 | 2817.1 | 2.0 | False | None | None | False | None | False | 5634.2 | 0 |
3745141 | 139915 | None | code30 | 14.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Vol- 2 P-128/14.31. | No | 1342.0 | 1342.0 | 4.0 | False | None | None | False | None | False | 5368.0 | 0 |
3745142 | 139915 | None | code31 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.14.40.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. each 380.00 Vol- 2 P-130/14.40.2. | No | 545.6 | 545.6 | 4.0 | False | None | None | False | None | False | 2182.4 | 0 |
3745143 | 139915 | None | code32 | Providing and fixing Side operated Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Vol- 2 P-140/14.61.b (wall mixer with overhead shower) premium | No | 8940.8 | 8940.8 | 2.0 | False | None | None | False | None | False | 17881.6 | 0 |
3745144 | 139915 | None | code33 | Providing and fixing Single flow hand showers with Anti lime jets with1.5m PVC tube and holder made of Stainless steel with all concealed fittingarrangements & all necessary accesories complete - Class Vol- 2 P-143/14.78 (Health fawcet) premium | No | 1395.9 | 1395.9 | 3.0 | False | None | None | False | None | False | 4187.7 | 0 |
3745145 | 139915 | None | code34 | Providing and fixing 100 mm sand cast Iron grating for gully trap. vol- 2 P-128/14.29 | No | 51.7 | 51.7 | 6.0 | False | None | None | False | None | False | 310.2 | 0 |
3745146 | 139915 | None | code35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Vol-2,P122 /13.31.3.25 mm dia | Mtr | 349.8 | 349.8 | 30.0 | False | None | None | False | None | False | 10494.0 | 0 |
3745147 | 139915 | None | code36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Vol-2,P122 /13.31.4. 32 mm dia | Mtr | 440.0 | 440.0 | 50.0 | False | None | None | False | None | False | 22000.0 | 0 |
3745148 | 139915 | None | code37 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore Nos. Vol-02 P-117/13.4.1 | Each | 603.9 | 603.9 | 2.0 | False | None | None | False | None | False | 1207.8 | 0 |
3745149 | 139915 | None | code38 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore Nos. Vol-02 P-117/13.4.2 | Each | 657.8 | 657.8 | 2.0 | False | None | None | False | None | False | 1315.6 | 0 |
3745150 | 139915 | None | code39 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete F50mm dia | Mtr | 111.1 | 111.1 | 20.0 | False | None | None | False | None | False | 2222.0 | 0 |
3745151 | 139915 | None | code40 | 75 mm dia | Mtr | 242.0 | 242.0 | 20.0 | False | None | None | False | None | False | 4840.0 | 0 |
3745152 | 139915 | None | code41 | 110 mm dia | Mtr | 452.1 | 452.1 | 30.0 | False | None | None | False | None | False | 13563.0 | 0 |
3745153 | 139915 | None | code42 | 160 mm Dia | Mtr | 679.8 | 679.8 | 27.0 | False | None | None | False | None | False | 18354.6 | 0 |
3745154 | 139915 | None | code43 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials,labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.m2 864.00Volume- 2,P-14/6.12 | Sqm | 1103.3 | 1103.3 | 33.285 | False | None | None | False | None | False | 36723.3405 | 0 |
3745155 | 139915 | None | code44 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 4314.34 | 4314.34 | 0.89 | False | None | None | False | None | False | 3839.7626 | 0 |
3745156 | 139915 | None | code45 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Vol-2 P-42/13.34 | Ltr | 9.9 | 9.9 | 2000.0 | False | None | None | False | None | False | 19800.0 | 0 |
3745157 | 139915 | None | code46 | 13.27 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. mm nominal bore with 45 cm length Nos. 92.00 Volume- 2,P-119/13.27.2 15 | Nos | 127.6 | 127.6 | 10.0 | False | None | None | False | None | False | 1276.0 | 0 |
3745158 | 139915 | None | code47 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 P-119/13.12 of vol 2 | Each | 698.5 | 698.5 | 6.0 | False | None | None | False | None | False | 4191.0 | 0 |
3745159 | 139915 | None | code48 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge to the appropriate disposal area. P-193/19.59 of vol 2 | Sqm | 400.4 | 400.4 | 50.0 | False | None | None | False | None | False | 20020.0 | 0 |
3745160 | 139915 | None | code49 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.....P-191/16.10 of BWSSB SR | Nos | 4659.6 | 4659.6 | 8.0 | False | None | None | False | None | False | 37276.8 | 0 |
3745161 | 139915 | None | code50 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..P-191/16.9 of BWSSB SR | Nos | 5999.4 | 5999.4 | 4.0 | False | None | None | False | None | False | 23997.6 | 0 |
3745162 | 139915 | None | code51 | Providing Coursed rubble masonry (first sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)P- 8/5.2 of vol -2 | Cum | 7279.8 | 7279.8 | 31.077 | False | None | None | False | None | False | 226234.3446 | 0 |
3745163 | 139915 | None | code52 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicelylining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.P-44/8.19.1 of Vol - 2 | Sqm | 280.5 | 280.5 | 30.24 | False | None | None | False | None | False | 8482.32 | 0 |
3745164 | 139915 | None | code53 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification..Vol - 2,P-149/15.1 | Cum | 898.7 | 898.7 | 80.0 | False | None | None | False | None | False | 71896.0 | 0 |
3745165 | 139915 | None | code54 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box 2.2.1 | No | 295.9 | 295.9 | 4.0 | False | None | None | False | None | False | 1183.6 | 0 |
3745166 | 139915 | None | code55 | Do- Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 2.2.2 | No | 416.9 | 416.9 | 6.0 | False | None | None | False | None | False | 2501.4 | 0 |
3745167 | 139915 | None | code56 | Do- Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box 2.2.3 | No | 610.5 | 610.5 | 6.0 | False | None | None | False | None | False | 3663.0 | 0 |
3745168 | 139915 | None | code57 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick 1.2.2 | Mtr | 85.8 | 85.8 | 50.0 | False | None | None | False | None | False | 4290.0 | 0 |
3745169 | 139915 | None | code58 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick 1.3.2 | Mtr | 75.89 | 75.89 | 25.0 | False | None | None | False | None | False | 1897.25 | 0 |
3745170 | 139915 | None | code59 | Open Conduit System: Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick 1.1.1 | Mtr | 75.89 | 75.89 | 10.0 | False | None | None | False | None | False | 758.9 | 0 |
3745171 | 139915 | None | code60 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm 1.8.2 | Mtr | 38.49 | 38.49 | 10.0 | False | None | None | False | None | False | 384.9 | 0 |
3745172 | 139915 | None | code61 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2 2.3.2 | Mtr | 28.6 | 28.6 | 70.0 | False | None | None | False | None | False | 2002.0 | 0 |
3745173 | 139915 | None | code62 | Do- 2.5 mm2 2.3.3 | Mtr | 46.2 | 46.2 | 70.0 | False | None | None | False | None | False | 3234.0 | 0 |
3745174 | 139915 | None | code63 | Do- 4 mm2 2.3.4 | Mtr | 69.3 | 69.3 | 40.0 | False | None | None | False | None | False | 2772.0 | 0 |
3745175 | 139915 | None | code64 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way 3.3.1 | No | 113.3 | 113.3 | 5.0 | False | None | None | False | None | False | 566.5 | 0 |
3745176 | 139915 | None | code65 | Do- 3 Way 3.3.2 | No | 136.4 | 136.4 | 3.0 | False | None | None | False | None | False | 409.2 | 0 |
3745177 | 139915 | None | code66 | Do- 4-5 Way 3.3.3 | No | 150.7 | 150.7 | 2.0 | False | None | None | False | None | False | 301.4 | 0 |
3745178 | 139915 | None | code67 | Do- 6 Way 3.3.4 | No | 190.3 | 190.3 | 2.0 | False | None | None | False | None | False | 380.6 | 0 |
3745179 | 139915 | None | code68 | Do- 8 Way 3.3.5 | No | 240.9 | 240.9 | 2.0 | False | None | None | False | None | False | 481.8 | 0 |
3745180 | 139915 | None | code69 | Do- 10-12 Way 3.3.6 | No | 287.1 | 287.1 | 2.0 | False | None | None | False | None | False | 574.2 | 0 |
3745181 | 139915 | None | code70 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module 3.5.1 | No | 150.7 | 150.7 | 5.0 | False | None | None | False | None | False | 753.5 | 0 |
3745182 | 139915 | None | code71 | Do- 3 Module 3.5.2 | No | 177.1 | 177.1 | 3.0 | False | None | None | False | None | False | 531.3 | 0 |
3745183 | 139915 | None | code72 | Do- 4 Module 3.5.3 | No | 192.5 | 192.5 | 2.0 | False | None | None | False | None | False | 385.0 | 0 |
3745184 | 139915 | None | code73 | Do- 6 Module 3.5.4 | No | 257.4 | 257.4 | 2.0 | False | None | None | False | None | False | 514.8 | 0 |
3745185 | 139915 | None | code74 | Do- 8 Module 3.5.5 | No | 312.4 | 312.4 | 2.0 | False | None | None | False | None | False | 624.8 | 0 |
3745186 | 139915 | None | code75 | Do- 10-12 Module 3.5.6 | No | 378.4 | 378.4 | 2.0 | False | None | None | False | None | False | 756.8 | 0 |
3745187 | 139915 | None | code76 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch 3.6.1 | No | 112.2 | 112.2 | 30.0 | False | None | None | False | None | False | 3366.0 | 0 |
3745188 | 139915 | None | code77 | Do- 6A Three Way socket 3.6.3 | No | 188.1 | 188.1 | 10.0 | False | None | None | False | None | False | 1881.0 | 0 |
3745189 | 139915 | None | code78 | Do- Stepped Fan Regulator Two Module 3.6.4 | No | 392.7 | 392.7 | 4.0 | False | None | None | False | None | False | 1570.8 | 0 |
3745190 | 139915 | None | code79 | Do- 32A DP Switch 3.6.9 | No | 358.59 | 358.59 | 2.0 | False | None | None | False | None | False | 717.18 | 0 |
3745191 | 139915 | None | code80 | Do- 6/16A Universal Socket 3.6.10 | No | 259.6 | 259.6 | 2.0 | False | None | None | False | None | False | 519.2 | 0 |
3745192 | 139915 | None | code81 | Supplying of .....feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V at 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4' - 36/40 W 11.3.3 | No | 1395.9 | 1395.9 | 10.0 | False | None | None | False | None | False | 13959.0 | 0 |
3745193 | 139915 | None | code82 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. 13.7 | No | 134.2 | 134.2 | 10.0 | False | None | None | False | None | False | 1342.0 | 0 |
3745194 | 139915 | None | code83 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model 6.3.1 | No | 3282.4 | 3282.4 | 3.0 | False | None | None | False | None | False | 9847.2 | 0 |
3745195 | 139915 | None | code84 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. 13.10 | No | 188.1 | 188.1 | 3.0 | False | None | None | False | None | False | 564.3 | 0 |
3745196 | 139915 | None | code85 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) 6.2.1 | No | 3265.9 | 3265.9 | 2.0 | False | None | None | False | None | False | 6531.8 | 0 |
3745197 | 139915 | None | code86 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. 13.14 | No | 541.2 | 541.2 | 2.0 | False | None | None | False | None | False | 1082.4 | 0 |
3745198 | 139915 | None | code87 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP 5.18.1 | No | 456.5 | 456.5 | 2.0 | False | None | None | False | None | False | 913.0 | 0 |
3745199 | 139915 | None | code88 | Do- 6-32 A DP 5.18.4 | No | 812.9 | 812.9 | 2.0 | False | None | None | False | None | False | 1625.8 | 0 |
3745200 | 139915 | None | code89 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N 5.19.7 | No | 1970.1 | 1970.1 | 1.0 | False | None | None | False | None | False | 1970.1 | 0 |
3745201 | 139915 | None | code90 | Erection charges for fixing a ... litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate
and wiring complete with 15A 3 pin top. upto 30 Litres 13.15.1 | No | 730.4 | 730.4 | 1.0 | False | None | None | False | None | False | 730.4 | 0 |
3745202 | 139915 | None | code91 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Batten Holder 3.14.7 | No | 81.4 | 81.4 | 4.0 | False | None | None | False | None | False | 325.6 | 0 |
3745203 | 139915 | None | code92 | Do- 6A Bakelite Ceiling Rose 3.14.5 | No | 85.8 | 85.8 | 2.0 | False | None | None | False | None | False | 171.6 | 0 |