1723278577000 | 0 | None | None | Other Works | Construction of CC road from Akkamma Jamadar house to Shahpurkar & from Sharana Gouli house to Badi Ger to Modi Singh Thakur house at W.No.53 in Kalaburagi City. & Contruction of welcome arch at shree Guru Raghavendra swamy math mahadwar in Kalaburagi City (Category-Others) (Est. cost. 15.00 lakhs) (15th FC 2023-24) | 1249908.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3744475 | 139875 | None | 001 | EARTHWORK EXCAVATION UPTO 3.00m D
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 3.0m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Page No.8 Item No. 1.14.1 KPWD. Volumn -1 DSR 2023-24
In ordinary/soft rock without blasting upto 3.0 m depth | Cum | 107.1 | 107.1 | 58.59 | False | None | None | False | None | False | 6274.989 | 0 | 3744476 | 139875 | None | 002 | EARTH FILLING
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage& all other appurtenaces required to complete the work. Page No. 7
Item No. 1.8 KPWD. Volumn -1 DSR 2023-24 | Cum | 497.7 | 497.7 | 33.05 | False | None | None | False | None | False | 16448.985 | 0 | 3744477 | 139875 | None | 003 | PLAIN CEMENT CONCRETE
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Page No.15 Item No. 2.1,4 KPWD. Volumn -1 DSR 2023-24 BELOW FOOTINGS | Cum | 6527.85 | 6527.85 | 3.03 | False | None | None | False | None | False | 19779.3855 | 0 | 3744478 | 139875 | None | 004 | Providing and laying in position Cement Concrete for All Sub structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates. Page No.16 Item No. 2.4.3 KPWD. Volumn -1 DSR 2023-24 Footing (V-1 Pg No: 16, Item No: 2.4.3) | Cum | 6652.8 | 6652.8 | 20.86 | False | None | None | False | None | False | 138777.408 | 0 | 3744479 | 139875 | None | 005 | Providing and laying in position Cement Concrete for All Sub structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates. Page No.16 Item No. 2.4.3 KPWD. Volumn -1 DSR 2023-24 Column (V-1 Pg No: 16, Item No: 2.4.3) | Cum | 6652.8 | 6652.8 | 0.27 | False | None | None | False | None | False | 1796.256 | 0 | 3744480 | 139875 | None | 006 | Providing and laying in position Cement Concrete for All Sub structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates. Page No.16 Item No. 2.4.3 KPWD. Volumn -1 DSR 2023-24 Plinth Beam (V-1 Pg No: 16, Item No: 2.4.3) | Cum | 6652.8 | 6652.8 | 2.43 | False | None | None | False | None | False | 16166.304 | 0 | 3744481 | 139875 | None | 007 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Page No.16 Item No. 2.5.2 KPWD. Volumn -1 DSR 2023-24
M25 Design Mix Using 20 mm nominal size graded crushed coarse (V-1, Pg No 16, Item No: 2.5.2) Column | Cum | 7185.15 | 7185.15 | 4.86 | False | None | None | False | None | False | 34919.829 | 0 | 3744482 | 139875 | None | 008 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Page No.16 Item No. 2.5.2 KPWD. Volumn -1 DSR 2023-24
M25 Design Mix Using 20 mm nominal size graded crushed coarse (V-1, Pg No 16, Item No: 2.5.2) Roof Beam | Cum | 7185.15 | 7185.15 | 9.89 | False | None | None | False | None | False | 71061.1335 | 0 | 3744483 | 139875 | None | 009 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Page No.16 Item No. 2.5.2 KPWD. Volumn -1 DSR 2023-24
M25 Design Mix Using 20 mm nominal size graded crushed coarse (V-1, Pg No 16, Item No: 2.5.2) Roof Slab | Cum | 7185.15 | 7185.15 | 5.56 | False | None | None | False | None | False | 39949.434 | 0 | 3744484 | 139875 | None | 010 | CENTERING WORKS
Appendix I - Additionalities for Formwork, Centering & Scaffolding Page No.111-112 KPWD. Volumn -1 DSR 2023-24
Footing 8% | Cum | 532.22 | 532.22 | 20.86 | False | None | None | False | None | False | 11102.1092 | 0 | 3744485 | 139875 | None | 011 | CENTERING WORKS
Appendix I - Additionalities for Formwork, Centering & Scaffolding Page No.111-112 KPWD. Volumn -1 DSR 2023-24
Columns 70% | Cum | 4656.96 | 4656.96 | 5.13 | False | None | None | False | None | False | 23890.2048 | 0 | 3744486 | 139875 | None | 012 | CENTERING WORKS
Appendix I - Additionalities for Formwork, Centering & Scaffolding Page No.111-112 KPWD. Volumn -1 DSR 2023-24
Plinth Beam50% | Cum | 3326.4 | 3326.4 | 2.43 | False | None | None | False | None | False | 8083.152 | 0 | 3744487 | 139875 | None | 013 | CENTERING WORKS
Appendix I - Additionalities for Formwork, Centering & Scaffolding Page No.111-112 KPWD. Volumn -1 DSR 2023-24
Roof Beam 60% | Cum | 4311.09 | 4311.09 | 9.89 | False | None | None | False | None | False | 42636.6801 | 0 | 3744488 | 139875 | None | 014 | CENTERING WORKS
Appendix I - Additionalities for Formwork, Centering & Scaffolding Page No.111-112 KPWD. Volumn -1 DSR 2023-24
Roof slab 50% | Cum | 3592.58 | 3592.58 | 5.56 | False | None | None | False | None | False | 19974.7448 | 0 | 3744489 | 139875 | None | 015 | PLASTERING WORK
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Page No.42 Item no.8.9 KPWD. Volumn -2 DSR 2023-24 C1,C2,Main Beam, Beam Side Surface,Side Beams,Main Slab,Main Slab,Side Slab &NET QTY. | Sqm | 404.25 | 404.25 | 87.65 | False | None | None | False | None | False | 35432.5125 | 0 | 3744490 | 139875 | None | 016 | PLASTIC EMULSION PAINT
Painting with Silicon & Acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Page No. 47 Item no. 8.35.2 KPWD. Volumn -2 DSR 2023-24 Qty as per outside PLASTER | Sqm | 207.9 | 207.9 | 87.65 | False | None | None | False | None | False | 18222.435 | 0 | 3744491 | 139875 | None | 017 | EXTERIOR PAINT
Finishing walls with textured exterior paint of required shade New work (Two coats applied at 3.28 ltr/10 m) over and including priming coat of exterior primer applied at 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drop and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Page No. 45 Item no. 8.29 KPWD. Volumn -2 DSR 2023-24Qty as per outside PLASTER | Sqm | 297.15 | 297.15 | 87.65 | False | None | None | False | None | False | 26045.1975 | 0 | 3744492 | 139875 | None | 018 | T.M.T STEEL
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
Page No.18 Item no. 2.11 (a) KPWD. Volumn -1 DSR 2023-24
Footing
Columns
Plinth Beam
Roof Beam
Roof Slab | Tonne | 93929.85 | 93929.85 | 6.46 | False | None | None | False | None | False | 606786.831 | 0 | 3744493 | 139875 | None | 020 | Supplying heavy gauge PVC conduit pipe .2. mm dia.25.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary
page no 2 item no 1.2.2
25 mm dia 2 mm thick | Rmtr | 78.0 | 78.0 | 50.0 | False | None | None | False | None | False | 3900.0 | 0 | 3744494 | 139875 | None | 020 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/Gl pipe and plastering, finishing upto wall surface complete.
page no 3 of item no 1.7.1 up to 50 mm | Rmtr | 29.0 | 29.0 | 15.0 | False | None | None | False | None | False | 435.0 | 0 | 3744495 | 139875 | None | 021 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.55q.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP
short point up to 3 mtr from tapping point out let via switch page no 5 of item no 2.1.1 | Point | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | 3744496 | 139875 | None | 022 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.55q.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP
Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch page no 5 item no 2.1.2 | Point | 394.0 | 394.0 | 1.0 | False | None | None | False | None | False | 394.0 | 0 | 3744497 | 139875 | None | 023 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.55q.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP
long above 6 mtr up to 10 mr from tapping point to out let via switch page no 5 item no 2.1.3 | Point | 570.0 | 570.0 | 3.0 | False | None | None | False | None | False | 1710.0 | 0 | 3744498 | 139875 | None | 024 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS
1293 and IS 3654
page no 8 of item no 3.1.2 (6 amps 3/5 way) | Each | 147.0 | 147.0 | 2.0 | False | None | None | False | None | False | 294.0 | 0 | 3744499 | 139875 | None | 025 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12 way (page no 8 item no 3.4.6) | Each | 319.0 | 319.0 | 1.0 | False | None | None | False | None | False | 319.0 | 0 | 3744500 | 139875 | None | 026 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5 way (Pg No 8 Item No 3.4.3) | Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 | 3744501 | 139875 | None | 027 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 way (Pg No 8 Item No 3.3.5) | Each | 261.0 | 261.0 | 1.0 | False | None | None | False | None | False | 261.0 | 0 | 3744502 | 139875 | None | 028 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
page no 8
4 modular (page no 5 item no 3.5.3) | Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 | 3744503 | 139875 | None | 029 | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCBs as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440 Volts 3phase 4 wire powder coated painting etc. Complete with a provision for fixing of single /three phase suitable capacity MCCB/MCBs as outgoings confirming to IS8828. (page no 18 of item no 5.19.1) 4 Way SP and N | Each | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 | 3744504 | 139875 | None | 030 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SP (page no 17 item no 5.18.1) | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | 3744505 | 139875 | None | 031 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment
2.5 sq mm (page no 5 item no 2.3.3) | Rmtr | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 | 3744506 | 139875 | None | 032 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment
4 Sq mm (Pg No 5 Item NO 2.3.4) | Rmtr | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 | 3744507 | 139875 | None | 033 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body withlocking type hold ercompletely wired.Excluding Ballast & Fluorescent Tube
1 x 4' Tube light fitting. (page no 47 of item no 11.13.2) | Each | 269.0 | 269.0 | 1.0 | False | None | None | False | None | False | 269.0 | 0 | 3744508 | 139875 | None | 034 | Supply of LED flood light luminaire with pressure diecast aluminium housing body for optimal the rmaldissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycar bonate/ clear glass material, delivering superior light output Rate dlife Burning Hrs 50000hr at Lumen Maintenance of 70percent ,CCT 5500K, 1P66 optical andel ectrical compartment & impact resistance of complete luminaire K08. Power Factor 0.9withmains, Surge Protection Min 5KV along with Over voltage/ Overload, shortcircuit/ miss-wiring protection. Compatible for polemauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltagerange from 100V to 270V50/60Hz application. Compliance to IS10322/ IEC60598, LM79 & LM80 Adherence with RoHS. UL approved MCPCB. Top accesss tree tlight with single screw to ensuree ase of maintenance at the sight site location with minimized minimal tools. LED Light fixture with. W System Power consumption. LED Efficiency 1301m/w ,nominalCRI 75. Luminaire manufacturers houldhavein-house facility accredited by NABL/CPRI& any Government certifiedagency &Design &Development facility ertified by IS09001 2008 Housing with supplier word mark/ name shallbe Engraved/Embossin gonthediecasthousing/ BodypartWarrantyof2 Years against any manufacturing defect working under standar delectrical condition sasmentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osrammake LED Source. LED Flood light 120W (page no 460f item no 11.9.3) | Each | 10757.0 | 10757.0 | 7.0 | False | None | None | False | None | False | 75299.0 | 0 | 3744509 | 139875 | None | 035 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut- outs & other equipments back fillcompound whichisnon-corrosive, thermally conductive, potentiall topermissible limits, superior Faultconduction capacity, non toxic, weatherr esistance & capable of achieving ohmic value less than one ohm page no 55 item no 12.60.2
Using 6ft. Copper bonded rod with backfill compound | 1 Kit | 6230.0 | 6230.0 | 4.0 | False | None | None | False | None | False | 24920.0 | 0 | 3744510 | 139875 | None | 036 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC
60898.50-63 A DP (page no 18 item no 5.18.6) | Each | 1102.0 | 1102.0 | 1.0 | False | None | None | False | None | False | 1102.0 | 0 |
|