createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722512589842
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1390.00
emd110000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose22-08-2024 16:00:00
tenderQueryClose20-08-2024 16:00:00
technicalBidOpen23-08-2024 16:10:00
publishedDate12-08-2024 11:08:12
publishedByPostEWHFWD_EE_EEOFF_MYS
publishedByUserKPE12441 - H SRINIVASAGOWDA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonManasa
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9449843319
tenderSupplierListNone
tenderSchedule
createdTs1722512589870
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT516
titleCONSTRUCTION OF 45 KLD CAPACITY DEWATTS SEWAGE TREATMENT PLANT AT GOVT HIGH TECH PANCHAKARMA HOSPITAL, KRS ROAD, MYSURU.
descriptionCONSTRUCTION OF 45 KLD CAPACITY DEWATTS SEWAGE TREATMENT PLANT AT GOVT HIGH TECH PANCHAKARMA HOSPITAL, KRS ROAD, MYSURU.
categoryWORKS
categoryTextWorks
ecv5523857.38
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3523
locationNameEWHFWD Executive Engineer Office Mysore
provisionalAmount6000000.0
groupOverheadTotal0.0
fileNumberHFW/AEE/MYS/STP/PANCHAKARMAHOSP
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17225125900000NoneNoneBuildingsCONSTRUCTION OF 45 KLD CAPACITY DEWATTS SEWAGE TREATMENT PLANT AT GOVT HIGH TECH PANCHAKARMA HOSPITAL, KRS ROAD, MYSURU. (Civil Works)4415070.38
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3668132133969NoneI-2.5(ii)b P-9 V-3Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of thorny jungle100 Sqm599.68599.681.25FalseNoneNoneFalseNoneFalse749.60
3668133133969NoneI-1.14.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.38126.38476.91FalseNoneNoneFalseNoneFalse60271.88580
3668134133969NoneI-1.9 P-7 V-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5789.24FalseNoneNoneFalseNoneFalse29410.82680
3668135133969NoneI-2.1.4 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Formwork inculded)Cum7702.867702.8616.05FalseNoneNoneFalseNoneFalse123630.9030
3668136133969NoneI-2.11a P-18 V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne110837.22110837.2218.15FalseNoneNoneFalseNoneFalse2011695.5430
3668137133969NoneI-2.3.3 P-16 V-1Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork inculded) RaftCum8429.18429.139.09FalseNoneNoneFalseNoneFalse329493.5190
3668138133969NoneI-2.3.3 P-16 V-1Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) WallCum9001.959001.9587.68FalseNoneNoneFalseNoneFalse789290.9760
3668139133969NoneI-2.3.3 P-16 V-1Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) RoofCum12275.3912275.3924.02FalseNoneNoneFalseNoneFalse294854.86780
3668140133969NoneI-2.3.3 P-16 V-1Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) ColumnsCum13912.1213912.120.27FalseNoneNoneFalseNoneFalse3756.27240
3668141133969NoneI-7.18 P-22 V-2Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slopecompacting, including cost of materials, labour, curing complete as per specifications.Cum2499.062499.062.8FalseNoneNoneFalseNoneFalse6997.3680
3668142133969NoneI-4.24 2018-19 SRKSRB 4-4.1 Extra for use of water proofing compound in Cement concrete of mix 1:1:2,at one kg of compound per bag of cement.Specification No. KBSCum254.02254.0239.09FalseNoneNoneFalseNoneFalse9929.64180
3668143133969NoneI-8.6.2 P-42 V-2Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No 8.6.2)Sqm531.53531.53597.72FalseNoneNoneFalseNoneFalse317706.11160
3668144133969NoneI-8.12 P-43 V-2Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer- in-Charge. (Item No 8.18)Sqm79.379.3597.72FalseNoneNoneFalseNoneFalse47399.1960
3668145133969NoneI-8.10 P-43 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.43103.34FalseNoneNoneFalseNoneFalse27016.17620
3668146133969NoneI-8.30 P-46 V-2Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No 8.30)Sqm215.59215.5968.6FalseNoneNoneFalseNoneFalse14789.4740
3668147133969NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Item No 8.39)Sqm157.35157.3575.09FalseNoneNoneFalseNoneFalse11815.41150
3668148133969NoneI-11.5.1 P-77 V-2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No 11.5.1)Sqm5548.245548.242.52FalseNoneNoneFalseNoneFalse13981.56480
3668149133969NoneA.RProviding & fixing 1 HP Mono block pump of approved make with all accessories etc.., complete including cost of materials, labour as per specifications.& as per the direction of the Engineer - in - chargeNos8260.08260.02.0FalseNoneNoneFalseNoneFalse16520.00
3668150133969NoneI-10.14.8 P-120 V-5Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying trueto line, level and perfect linking at joints leak proof including jointingof approved type with all labour charges and all lift charges, handlingcharges including encasing the pipe around to a depth not less than15 cms with gravel or selected earth available from the excavation etc.complete.6 Kg/m2:63mm(weight of pipe -0.662 kgm172.22172.22150.0FalseNoneNoneFalseNoneFalse25833.00
3668151133969NoneV-2 P-122 I 13.31.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes JOinting of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 20mm DiaMtr299.84299.84120.0FalseNoneNoneFalseNoneFalse35980.80
3668152133969NoneI-2.1.3 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates.Cum7420.377420.371.3FalseNoneNoneFalseNoneFalse9646.4810
3668153133969NoneI-5.4 P-9 V-2Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7915.977915.971.9FalseNoneNoneFalseNoneFalse15040.3430
3668154133969NoneI-2.1.6 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates.Cum7735.087735.081.8FalseNoneNoneFalseNoneFalse13923.1440
3668155133969NoneI-5.4 P-9 V-2Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum13600.513600.56.4FalseNoneNoneFalseNoneFalse87043.20
3668156133969NoneI-8.8 P-43 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.6741.4FalseNoneNoneFalseNoneFalse19030.3380
3668157133969NoneI-10.14.7 P-120 V-5Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 200mm( weight of pipe -4.256 kg)m883.41883.4130.0FalseNoneNoneFalseNoneFalse26502.30
3668158133969NoneI-10.14.11 P-120 V-5Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kg/sqcm & class 3m443.56443.5640.0FalseNoneNoneFalseNoneFalse17742.40
3668159133969NoneI-13.55 P-127 V-2Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floatingcoat of neat cement on walls and bed concrete etc.complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay (non modular) bricks of class designation 3.5.Each9169.849169.846.0FalseNoneNoneFalseNoneFalse55019.040
17225125900000NoneNoneBuildingsCONSTRUCTION OF 45 KLD CAPACITY DEWATTS SEWAGE TREATMENT PLANT AT GOVT HIGH TECH PANCHAKARMA HOSPITAL, KRS ROAD, MYSURU. (DEWATTS SEWAGE TREATMENT PLANT)1108787.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3668160133970NoneI-1ELECTRO-MECHANICAL EQUIPMENTS FOR 45 KLD HYBRID DEWATTS SEWAGE TREATMENT PLANT Design, Supply, Unloading, Shifting, Installation, Testing and Commissioning of 45KLD Hybrid DEWATTS technology Sewage Treatment Plant (STP) consisting of Raw Sewage Lifting Pumps, Filter Feed Pumps, Dual Media Filter and Ozone Disinfection system with Bar Screen, Grease Trap, & outlet water flow meter and all electrical works, automation based control panel, mechanical, plumbing, processing, ancillary equipments works include all power cabling, control wiring from control panel to pump motor including power and control wiring and controller maintenance, shop drawing etc., as required includes all Mechanical, Piping and ELectrical works and all complete as specified in item description and tender specifications including all required accessories to complete the job as per the satisfaction of PMC/Chief Engineer,. (Treated water quality as per KSPCB). Nature of effluent - Sewage from Toilets, Residential Kitchens and Utilities. Daily average flow - 45 KLD STP. Supply, Installation, Testing and Commissioning of following Electromechanical Equipments as mentioned below. Bar Screen : Design, manufacture / procurement, Supply, Installation, Testing and Commissioning of bar screen as per following details : MOC - SS 316 Size - 750 mm X 750 mm or as per Vendor Main Frame - SS Sheet x 3 thick min. Bars - SS round bars 4 mm dia.or as per Vendor Bar gap Spacing - 10 mm spacing or as per Vendor. Accessories - Anchor Fasteners for fittings, matching comber with long handle (PVC) for removing floating solids. Nos17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3668161133970NoneI-2Raw Sewage Lifting Pumps : Supply, Installation, Testing and Commissioning of compact monoblock dry motor submersible non-cutter pumps of suitable rating, with non-clog free flow open CI impeller, CI casing and SS Shaft, suitable for operation on 415 volts plus or minus 10% , 3 Phase motor, 50Hz, A.C supply, speed 2900 RPM, including oil chamber, guide wire for lifting & lowering of pump, all complete as required in all respects. The pump sets shall be supplied with required accessories & as per specification with the following : Pump Headers and other interconnecting pipes (UPVC Sch 80,) Complete inlet, outlet and header piping of suitable dia (velocity shall not exceed 1.5m/s) 1 Lot Discharge : 5 m3/Hr Head : 8 10 m Solid Handling : Up to 35 mm Power : 0.75 K.W / 1.0 H.P , 1 or 3 Phase 415 V Type : Sewage Cutter Pumps Qty : ( 1 Working + 1 Standby ) - 1 set One set consist of 2 nos. of pumps - 1 working & 1 stand by (Complete set as above no. pumps including cost for valves, piping, Control Panel, Cabling, contactors, breakers, overload relay, Level Controllers, float switch, etc., as required and as specified and any other additional items to make the system complete)Set76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3668162133970NoneI-3FILTER FEED PUMPS : Supply, Installation, Testing and Commissioning of Horizontal Centrifugal Pump as per IS 6595 (Part 2), CI body and CI impeller, shaft of CI with mechanical seal, connected to a TEFC induction motor suitable for 400/440 volts, 3 phase 50 cycle AC supply with 100mm dia. pressure gauge with syphon, gun metal isolation cock at delivery of each pump with interconnecting pipes, ball/butterfly and non return valves including vibration elimination pads as required all mounted in a common MS fabricated base plate bolted to cement concrete foundation complete. Pump Headers and other interconnecting pipes (UPVC Sch 80,) Complete inlet, outlet and header piping of suitable dia (velocity shall not exceed 1.5m/s) : 1 Lot Discharge : 7 m3/Hr Head : 20 m Solid Handling : Up to 5 mm Power : 1.5 K.W / 2.0 H.P , 1 or 3 Phase 415 V Type : Monobloc centrifugal Pumps Qty : ( 1 Working + 1 Standby ) - 1 set One set consist of 2 nos. of pumps - 1 working & 1 stand by (Complete set as above no. pumps including cost for valves, piping, Control Panel, Copper Cabling, contactors, breakers, overload relay, Level Controllers, float switch with necessary earthing etc., as required and as specified and any other additional items to make the system complete) Set100300.0100300.01.0FalseNoneNoneFalseNoneFalse100300.00
3668163133970NoneI-4Ozone Disinfection System : Providing and fixing in position completely automatic ozone generator from atmospheric air for treated disinfection along with Ozone Concentrator with all necesary accessories such as flow switch and all necessary accessories.The system shall be made from SS 316L SS core for all wetted and parts in contact with ozone or air. The system shall have all necessary controls and accessories,including cables for installation, along with venturi for injection etc with approprite capacity., complete as per specification & directed by Engineer- In-Charge in accordance with approved shop drawings. Ozone Generator Ozone Generator 20gm/hr Oxygen Concentrator 10 lpm Teflon Tube 6mm Polyurethane Tube 10mm Ozone Injection Probe SS Power Supply : 230V AC, 50Hz, 1Phase Ozone Concentrator Type : PSA Technology Compressor : Inbuilt Oil free Compressor Piston Type Oxygen capacity : 10lpm Max at 0.50kg/cm2 pressure Oxygen concentration : 93% Oxygen Purity +/- 3% Power Supply : 230V AC, 50Hz, 1Phase Set271400.0271400.01.0FalseNoneNoneFalseNoneFalse271400.00
3668164133970NoneI-5Dual Media Filter : Supply, Installation, Testing and Commissioning of MS fabricated Epoxy Painted vertical filter with adequate dirt holding capacity. Fabricated from MS sheet as per following specifications complete with initial charge filter media including painting inside with two coats of non toxic epoxy and with one coat of zinc chromate two coats of synthetic enamel paint outside. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping and Multiport Valve designed on 1.50 m/sec velocity complete as required in all respects. Dual Media Filter for Tertiary Treatment services. Shell thickness : 6 mm. Dished ends : 6 mm HOS : 1800 mm height Dia of filter approx. : 800 mm Dia Filtration Capacity : 7 m3/hr Filtration Rate : 14000 ltr./hr./m2 Filter Media : Silex Quartz, (Multigrade) and Anthracite Material of Construction : M.S. Epoxy Painted Manhole size : 450/ 600 mm Working Pressure : 2.5 - 3.5 Kg/Sq.cm. Set188800.0188800.01.0FalseNoneNoneFalseNoneFalse188800.00
3668165133970NoneI-6Electrical works including main electrical panel- self standing floor mounted, Non Compartmantalized panel, along with copper flat / round armounted cabling from panel to all equipments inside the STP. Cable shall be properly clamped on the ceiling or on GI perforated cable tray while dropping down. (Only incoming power input cable will be provided by other agency.) Complete electrical works including copper earthing with 8 swg Copper wire is inside the scope of STP vendor. Busbar inside the panel shall be with copper with a current carrying density of maximum 1.2 amps / sq.mm. Panel Incomer shall be 63 A 4 pole MCB with 96 x 96 size digital meter for voltage, ampere and kwh. Outgoings shall be suitably sized MCBs. Panel sholud be Minimum IP 55 with Dust Proof and Splash Proof. Electromagnetic Flow meters to be added along with potential free contacts for all the ougoinbg feeders in the panel. Earthing option to be provided for the panel. Feeder Details a. Raw Sewage Transfer Pumps : 0.75 K.W b. Filter Feed Pumps : 1.5 K.W c. Ozone Disinfection System : 0.2 K.W d. Treated Water Pumps : 1.5 K.W Required MCB's Relays, Push Button Starters Busbar, Indication Lamps, Control Trasnformer etc to be provided as required. The panel to be provided with a 1 no combined digital VAF meter Set88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
3668166133970NoneI-7PLANT ELECTRICAL CABLING WORK Supply, installation testing and commissioning of Inter unit Plant Electrical with cabling of 4 core copper armoured cables run in G.I perforated cable tray and fittings for all electrical lines and MS supports for cable tray and fittings. Type : Copper Armoured 4 core cable with G.I Cable trays a. 2.5 Sqmm Copper armoured Cable with 75-100mm G.I Cable Trays with all cable ties supports etc complete Rmtr472.0472.0125.0FalseNoneNoneFalseNoneFalse59000.00
3668167133970NoneI-8INTER UNIT PIPING WORKS Supply, Installation, Testing and Commissioning all piping (as described below) and isolation control valves for making the system, all complete as required in all respects. complete as per specification & directed by Engineer- In-Charge of the work. "Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge" Dia 40mmRmtr358.72358.7280.0FalseNoneNoneFalseNoneFalse28697.60
3668168133970NoneI-9INTER UNIT PIPING WORKS Supply, Installation, Testing and Commissioning all piping (as described below) and isolation control valves for making the system, all complete as required in all respects. complete as per specification & directed by Engineer- In-Charge of the work. "Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge Dia 100mm Rmtr1097.41097.480.0FalseNoneNoneFalseNoneFalse87792.00
3668169133970NoneI-10INTER UNIT PIPING WORKS Supply, Installation, Testing and Commissioning all piping (as described below) and isolation control valves for making the system, all complete as required in all respects. complete as per specification & directed by Engineer- In-Charge of the work. "Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge Dia 150mm Rmtr1879.741879.7410.0FalseNoneNoneFalseNoneFalse18797.40
3668170133970NoneI-11Instrumentation works Supplying Instalaltion and Testing Commissioning of Dia 40 mm Electro-Magnetic Flowmter ( For Sewage Application ) No41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3668171133970NoneI-12Supplying and Instalaltion of Level Sensors including wiring and installation Nos5900.05900.02.0FalseNoneNoneFalseNoneFalse11800.00
3668172133970NoneI-13Supply and adding require Cowdung and anaerbic bacteria culture for charging the Anaerobic Reactors and compelte commissioning. Lot47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3668173133970NoneI-14Design, consultancy and Preparation of Drawing charges l70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17225125910000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17225125910001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government / Government of India /Union TerritoryNone
17225125910000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17225125910000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17225125910000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17225132630000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPPP portal due to internet connectivity issues and technical glitches at bidders endNone
17225133140000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17225133690000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17225133870000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17225134060000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17225134440000NoneNoneELIGIBILITYMaterials like, steel, cement etc., required for the work shall be procured by the tenderer themselves and should got tested positive by the quality control authority before use on the workNone
17225134680000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17225134880000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17225135100000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (Section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17225135310000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17225135710000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within a weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as non responsiveNone
17225135890000NoneNoneELIGIBILITYAdditional Clause: In the case of the death of a contractor after executing the agreement / commencement of the work, his legal heir, if an eligible registered contractor and willing, can execute and complete the work at the accepted tender rates irrespective of the cost of the workNone
17225136030000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17225136140000NoneNoneELIGIBILITYGST registration certificate should be enclosedNone
17225136250000NoneNoneELIGIBILITYThe rates quoted shall be inclusive of GSTNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Similar nature of STP work of value not less than Rs. 27.62 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity ). (1)Earthwork Excavation -452.92Cum. (2) Cement Concrete -161.00 Cum.(3) Painting -114.95 Sqm.(4) Plastering - 1072.14 Sqm.(5) Steel Reinforcement for RCC work - 14.52 Tonnes.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs. 16.57 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least Two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 55.23 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate in the last five years 2019-20 to 2023-24 issued by charted accountant.TrueTechnical Bid
Work done certificate to be uploaded, which has to be issued not below the rank of Executive Engineer.TrueTechnical Bid
KPWD Class-III and above Registration Certificate.TrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone