3755599 | 141041 | None | code01 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 8861.0 | 8861.0 | 12.57 | False | None | None | False | None | False | 111382.77 | 0 |
3755600 | 141041 | None | code02 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 9485.0 | 9485.0 | 4.62 | False | None | None | False | None | False | 43820.7 | 0 |
3755601 | 141041 | None | code03 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specificationBuildings& with all lead and lift. and as per direction of the Engineer in charge of work. | t | 89457.0 | 89457.0 | 0.23 | False | None | None | False | None | False | 20575.11 | 0 |
3755602 | 141041 | None | code04 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 1663.0 | 1663.0 | 1.53 | False | None | None | False | None | False | 2544.39 | 0 |
3755603 | 141041 | None | code05 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 349.0 | 349.0 | 169.53 | False | None | None | False | None | False | 59165.97 | 0 |
3755604 | 141041 | None | code06 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 354.0 | 354.0 | 16.12 | False | None | None | False | None | False | 5706.48 | 0 |
3755605 | 141041 | None | code07 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 124202.0 | 124202.0 | 0.05 | False | None | None | False | None | False | 6210.1 | 0 |
3755606 | 141041 | None | code08 | Providing and fixing in position fully panelled Honne wood /Nandhi shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 6897.0 | 6897.0 | 2.0 | False | None | None | False | None | False | 13794.0 | 0 |
3755607 | 141041 | None | code09 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding & with all lead and lift. and as per direction of the Engineer in charge of work. | Kg | 168.0 | 168.0 | 35.91 | False | None | None | False | None | False | 6032.88 | 0 |
3755608 | 141041 | None | code10 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and aking provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. & with all lead and lift. and as per direction of the Engineer in charge of work. | Kg | 582.0 | 582.0 | 15.0 | False | None | None | False | None | False | 8730.0 | 0 |
3755609 | 141041 | None | code11 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 1171.0 | 1171.0 | 1.44 | False | None | None | False | None | False | 1686.24 | 0 |
3755610 | 141041 | None | code12 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 2852.0 | 2852.0 | 20.34 | False | None | None | False | None | False | 58009.68 | 0 |
3755611 | 141041 | None | code13 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 169.53 | False | None | None | False | None | False | 23225.61 | 0 |
3755612 | 141041 | None | code14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.0 | 167.0 | 7.74 | False | None | None | False | None | False | 1292.58 | 0 |
3755613 | 141041 | None | code15 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 138.0 | 138.0 | 135.0 | False | None | None | False | None | False | 18630.0 | 0 |
3755614 | 141041 | None | code16 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 291.0 | 291.0 | 12.0 | False | None | None | False | None | False | 3492.0 | 0 |
3755615 | 141041 | None | code17 | Providing & Fixing Mosquito mesh shutters made out of Stainless Steel mosquito proof mesh with 95% & above visibility which is fixed to the powder coated aluminium frame 20mm thick of approved shade. The work including fixing the shutters with necessary accessories, to complete as per specification including the labour charges for fixing the shutter to the existing frames. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 2900.0 | 2900.0 | 11.16 | False | None | None | False | None | False | 32364.0 | 0 |
3755616 | 141041 | None | code18 | Supplying PVC/GI flexible conduit pipe 20 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 19.0 | 19.0 | 20.0 | False | None | None | False | None | False | 380.0 | 0 |
3755617 | 141041 | None | code19 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A. 1.5sqmm & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 |
3755618 | 141041 | None | code20 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A.2.5sqmm & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 |
3755619 | 141041 | None | code21 | SWITCHES, SOCKETS & ACCESSORIES 6Amps 3/5 Way & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 |
3755620 | 141041 | None | code22 | Supply box type fluorescent tube light fitting of 4'- 36/40 watts fluorescent tube fitting, made out of M.S sheet and stove enameled with low loss open construction copper wound ferromagnetic ballast, starter, locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 Volts A C Supply including fluorescent tube. 2x4'-36/40Watts, Group 'A' & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 950.0 | 950.0 | 1.0 | False | None | None | False | None | False | 950.0 | 0 |