1723449783000 | 0 | None | None | Buildings | Construction of new building and toilet of J.Venkatapur Veterinary Clinic, Shidlaghatta Taluk | 1269746.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3755350 | 141028 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m.& with all lead and lift. and as per direction of the Engineer in charge | Cum | 102.0 | 102.0 | 65.11 | False | None | None | False | None | False | 6641.22 | 0 | 3755351 | 141028 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.& with all lead and lift. and as per direction of the Engineer in charge | Cum | 5664.0 | 5664.0 | 8.3 | False | None | None | False | None | False | 47011.2 | 0 | 3755352 | 141028 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).& with all lead and lift. and as per direction of the Engineer in charge | Cum | 5611.0 | 5611.0 | 19.58 | False | None | None | False | None | False | 109863.38 | 0 | 3755353 | 141028 | None | code04 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand).& with all lead and lift. and as per direction of the Engineer in charge | Cum | 6205.0 | 6205.0 | 7.75 | False | None | None | False | None | False | 48088.75 | 0 | 3755354 | 141028 | None | code05 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.including form work& with all lead and lift. and as per direction of the Engineer in charge | Cum | 6790.0 | 6790.0 | 5.73 | False | None | None | False | None | False | 38906.7 | 0 | 3755355 | 141028 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. .including form workM20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.& with all lead and lift. and as per direction of the Engineer in charge | Cum | 9945.0 | 9945.0 | 20.75 | False | None | None | False | None | False | 206358.75 | 0 | 3755356 | 141028 | None | code07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings & with all lead and lift. and as per direction of the Engineer in charge of work. | t | 89457.0 | 89457.0 | 1.66 | False | None | None | False | None | False | 148498.62 | 0 | 3755357 | 141028 | None | code08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.& with all lead and lift. and as per direction of the Engineer in charge . | Sqm | 1310.0 | 1310.0 | 158.84 | False | None | None | False | None | False | 208080.4 | 0 | 3755358 | 141028 | None | code09 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4242.0 | 4242.0 | 3.15 | False | None | None | False | None | False | 13362.3 | 0 | 3755359 | 141028 | None | code10 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kg | 136.0 | 136.0 | 221.94 | False | None | None | False | None | False | 30183.84 | 0 | 3755360 | 141028 | None | code11 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Mtr | 318.0 | 318.0 | 15.0 | False | None | None | False | None | False | 4770.0 | 0 | 3755361 | 141028 | None | code12 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 279.0 | 279.0 | 371.17 | False | None | None | False | None | False | 103556.43 | 0 | 3755362 | 141028 | None | code13 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. | Sqm | 354.0 | 354.0 | 66.55 | False | None | None | False | None | False | 23558.7 | 0 | 3755363 | 141028 | None | code14 | KSRB13-6.6-3 : Providing and fixing unplasticised PVC connection pipe with brass union 20mm nominal bore 300 mm length of PVC connection including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. .& with all lead and lift. and as per direction of the Engineer in charge | Mtr | 291.0 | 291.0 | 18.0 | False | None | None | False | None | False | 5238.0 | 0 | 3755364 | 141028 | None | code15 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.& with all lead and lift. and as per direction of the Engineer in charge | Sqm | 1145.0 | 1145.0 | 40.07 | False | None | None | False | None | False | 45880.15 | 0 | 3755365 | 141028 | None | code16 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete..& with all lead and lift. and as per direction of the Engineer in charge | Sqm | 1076.0 | 1076.0 | 17.88 | False | None | None | False | None | False | 19238.88 | 0 | 3755366 | 141028 | None | code17 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications..& with all lead and lift. and as per direction of the Engineer in charge | Sqm | 1392.0 | 1392.0 | 22.13 | False | None | None | False | None | False | 30804.96 | 0 | 3755367 | 141028 | None | code18 | Orissa pattern W.C. pan of size 580x440 mm.& with all lead and lift. and as per direction of the Engineer in charge | No | 2331.0 | 2331.0 | 2.0 | False | None | None | False | None | False | 4662.0 | 0 | 3755368 | 141028 | None | code19 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.& with all lead and lift. and as per direction of the Engineer in charge | No | 4121.0 | 4121.0 | 2.0 | False | None | None | False | None | False | 8242.0 | 0 | 3755369 | 141028 | None | code20 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 148.0 | 148.0 | 234.27 | False | None | None | False | None | False | 34671.96 | 0 | 3755370 | 141028 | None | code21 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with one side prelam | Sqm | 2040.0 | 2040.0 | 4.5 | False | None | None | False | None | False | 9180.0 | 0 | 3755371 | 141028 | None | code22 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm
nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand :
4 graded stone aggregate) finished with a floating coat of neat cement,
including cement slurry complete..& with all lead and lift. and as per direction of the Engineer in charge | Sqm | 451.0 | 451.0 | 3.24 | False | None | None | False | None | False | 1461.24 | 0 | 3755372 | 141028 | None | code23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.0 | 100.0 | 207.93 | False | None | None | False | None | False | 20793.0 | 0 | 3755373 | 141028 | None | code24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes.& with all lead and lift. and as per direction of the Engineer in charge | Mtr | 182.0 | 182.0 | 35.0 | False | None | None | False | None | False | 6370.0 | 0 | 3755374 | 141028 | None | code25 | Providing and fixing Inspection door.& with all lead and lift. and as per direction of the Engineer in charge | No | 1356.0 | 1356.0 | 1.0 | False | None | None | False | None | False | 1356.0 | 0 | 3755375 | 141028 | None | code26 | Providing and fixing RCC Rings .& with all lead and lift. and as per direction of the Engineer in charge | No | 650.0 | 650.0 | 4.0 | False | None | None | False | None | False | 2600.0 | 0 | 3755376 | 141028 | None | code27 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/ m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drain- age of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete..& with all lead and lift. and as per direction of the Engineer in charge | Sqm | 1170.0 | 1170.0 | 1.44 | False | None | None | False | None | False | 1684.8 | 0 | 3755377 | 141028 | None | code28 | Providing and fixing 1 HP Motor.& with all lead and lift. and as per direction of the Engineer in charge | No | 9000.0 | 9000.0 | 1.0 | False | None | None | False | None | False | 9000.0 | 0 | 3755378 | 141028 | None | code29 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately..& with all lead and lift. and as per direction of the Engineer in charge | l | 9.0 | 9.0 | 500.0 | False | None | None | False | None | False | 4500.0 | 0 | 3755379 | 141028 | None | code30 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 371.17 | False | None | None | False | None | False | 50850.29 | 0 | 3755380 | 141028 | None | code31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.0 | 167.0 | 28.59 | False | None | None | False | None | False | 4774.53 | 0 | 3755381 | 141028 | None | code32 | 2.5 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A. 2.5.2 1.5sqmm.& with all lead and lift. and as per direction of the Engineer in charge | Mtr | 20.5 | 20.5 | 120.0 | False | None | None | False | None | False | 2460.0 | 0 | 3755382 | 141028 | None | code33 | 2.5 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP-A. 2.5.2 1.5sqmm.& with all lead and lift. and as per direction of the Engineer in charge | Mtr | 45.0 | 45.0 | 120.0 | False | None | None | False | None | False | 5400.0 | 0 | 3755383 | 141028 | None | code34 | Supplying PVC/GI flexible conduit pipe⦠mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely.& with all lead and lift. and as per direction of the Engineer in charge | Mtr | 22.0 | 22.0 | 95.0 | False | None | None | False | None | False | 2090.0 | 0 | 3755384 | 141028 | None | code35 | Providing and fixing Junction box.& with all lead and lift. and as per direction of the Engineer in charge | No | 56.0 | 56.0 | 12.0 | False | None | None | False | None | False | 672.0 | 0 | 3755385 | 141028 | None | code36 | Providing and fixing Fan Metal box.& with all lead and lift. and as per direction of the Engineer in charge | No | 96.0 | 96.0 | 6.0 | False | None | None | False | None | False | 576.0 | 0 | 3755386 | 141028 | None | code37 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, and 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved.-48" Sweep (1200mm) Regular model (Khaitan, Crompton Greaves, Orient, Polar, Bajaj, Havells/Usha) [ .& with all lead and lift. and as per direction of the Engineer in charge | No | 2090.0 | 2090.0 | 4.0 | False | None | None | False | None | False | 8360.0 | 0 |
|