3745204 | 139916 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications . (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20Design Mix Using 20 mm nominal size graded crushed coarse aggregate | Cum | 7027.8 | 7027.8 | 150.79 | False | None | None | False | None | False | 1059721.962 | 0 |
3745205 | 139916 | None | code02 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 4919.46 | 4919.46 | 17.9 | False | None | None | False | None | False | 88058.334 | 0 |
3745206 | 139916 | None | code03 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 4216.68 | 4216.68 | 27.97 | False | None | None | False | None | False | 117940.5396 | 0 |
3745207 | 139916 | None | code04 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 3513.9 | 3513.9 | 94.01 | False | None | None | False | None | False | 330341.739 | 0 |
3745208 | 139916 | None | code05 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 4216.68 | 4216.68 | 8.73 | False | None | None | False | None | False | 36811.6164 | 0 |
3745209 | 139916 | None | code06 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 3162.51 | 3162.51 | 2.19 | False | None | None | False | None | False | 6925.8969 | 0 |
3745210 | 139916 | None | code07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. KPWD VOL-1 Item No. 2.11 ( a.) Page. No. 18 | Tonne | 94824.42 | 94824.42 | 20.41 | False | None | None | False | None | False | 1935366.4122 | 0 |
3745211 | 139916 | None | code08 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work. | Cum | 8447.14 | 8447.14 | 108.18 | False | None | None | False | None | False | 913811.6052 | 0 |
3745212 | 139916 | None | code09 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 255.46 | 255.46 | 1460.26 | False | None | None | False | None | False | 373038.0196 | 0 |
3745213 | 139916 | None | code10 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 393.26 | 393.26 | 715.33 | False | None | None | False | None | False | 281310.6758 | 0 |
3745214 | 139916 | None | code11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 106.0 | 106.0 | 1888.25 | False | None | None | False | None | False | 200154.5 | 0 |
3745215 | 139916 | None | code12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1245.5 | 1245.5 | 554.59 | False | None | None | False | None | False | 690741.845 | 0 |
3745216 | 139916 | None | code13 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge. | Sqm | 1637.7 | 1637.7 | 66.22 | False | None | None | False | None | False | 108448.494 | 0 |
3745217 | 139916 | None | code14 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 114.48 | 114.48 | 1460.26 | False | None | None | False | None | False | 167170.5648 | 0 |
3745218 | 139916 | None | code15 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 145.22 | 145.22 | 427.99 | False | None | None | False | None | False | 62152.7078 | 0 |
3745219 | 139916 | None | code16 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.48 | 167.48 | 858.84 | False | None | None | False | None | False | 143838.5232 | 0 |
3745220 | 139916 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kgs | 178.08 | 178.08 | 1134.0 | False | None | None | False | None | False | 201942.72 | 0 |
3745221 | 139916 | None | code18 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge. | Kgs | 146.28 | 146.28 | 89.1 | False | None | None | False | None | False | 13033.548 | 0 |
3745222 | 139916 | None | code19 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.. | Sqm | 5534.26 | 5534.26 | 9.24 | False | None | None | False | None | False | 51136.5624 | 0 |
3745223 | 139916 | None | code20 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brassProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and ot her sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. bras. | Sqm | 7138.04 | 7138.04 | 194.02 | False | None | None | False | None | False | 1384922.5208 | 0 |
3745224 | 139916 | None | code21 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 1047.28 | 1047.28 | 42.75 | False | None | None | False | None | False | 44771.22 | 0 |
3745225 | 139916 | None | code22 | Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm | Sqm | 296.8 | 296.8 | 18.09 | False | None | None | False | None | False | 5369.112 | 0 |
3745226 | 139916 | None | code23 | Providing & fixing of Aluminium Ventilators of frame size 40 x 18 mm of 1.3 mm thick, 0.933 Kg/ m all aluminium sections including cutting to required length, joints mitred subdiving the frame tenonned and riveted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs or teak wood gatties including supply along with fixing of SS - 304 mesh with necessary required materials etc., complete. | Sqm | 3370.8 | 3370.8 | 13.5 | False | None | None | False | None | False | 45505.8 | 0 |
3745227 | 139916 | None | code24 | Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 104743.9 | 104743.9 | 0.73 | False | None | None | False | None | False | 76463.047 | 0 |
3745228 | 139916 | None | code25 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1076.96 | 1076.96 | 6.0 | False | None | None | False | None | False | 6461.76 | 0 |
3745229 | 139916 | None | code26 | Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 6519.0 | 6519.0 | 18.66 | False | None | None | False | None | False | 121644.54 | 0 |
3745230 | 139916 | None | code27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 121.9 | 121.9 | 63.24 | False | None | None | False | None | False | 7708.956 | 0 |
3745231 | 139916 | None | code28 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 146.28 | 146.28 | 34.56 | False | None | None | False | None | False | 5055.4368 | 0 |
3745232 | 139916 | None | code29 | Providing and fixing on wall face unpasticised Rigid PVC rain water pipes conforming to ISI:13592 Type A including jointing with seal ring confroming to IS: 5382,leaving 10mm gap for thermal expansions, (i) single socked pipes 75mm diameter | Mtr | 197.0 | 197.0 | 26.0419 | False | None | None | False | None | False | 5130.2543 | 0 |
3745233 | 139916 | None | code30 | Mahalaxmi 1370 millimeter X 760 millimeter (mm LxD) Executive Computer Table
MahalaxmiR
(mct-887) | Nos | 11500.0 | 11500.0 | 20.0 | False | None | None | False | None | False | 230000.0 | 0 |
3745234 | 139916 | None | code31 | Unbranded Esd Chairs as per ANSI 520 20-2007
NA (KPESDCHAIRWA) | Nos | 10000.0 | 10000.0 | 50.0 | False | None | None | False | None | False | 500000.0 | 0 |
3745235 | 139916 | None | code32 | ALWIN Three seater classroom desking drawing
ALWINR (Bapl/Classroom Desk Bench/02) | Nos | 13000.0 | 13000.0 | 140.0 | False | None | None | False | None | False | 1820000.0 | 0 |
3745236 | 139916 | None | code33 | ViKTRON Sanitary Napkins Incinetator Machine with Smoke Control Unit ViKTRONR
(IS/VIK/INCIN/15-50(1-15)/0051) | Nos | 18000.0 | 18000.0 | 1.0 | False | None | None | False | None | False | 18000.0 | 0 |
3745237 | 139916 | None | code34 | Cello Pre treated and Epoxy powder coated finish Rectangular Classroom Stools Load of 75 Kg
CelloR (Ostrich) | Nos | 620.0 | 620.0 | 50.0 | False | None | None | False | None | False | 31000.0 | 0 |
3745238 | 139916 | None | code35 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications . (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate | Cum | 7094.1 | 7094.1 | 5.69 | False | None | None | False | None | False | 40365.429 | 0 |
3745239 | 139916 | None | code36 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 4965.87 | 4965.87 | 4.83 | False | None | None | False | None | False | 23985.1521 | 0 |
3745240 | 139916 | None | code37 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 4256.46 | 4256.46 | 0.74 | False | None | None | False | None | False | 3149.7804 | 0 |
3745241 | 139916 | None | code38 | Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof building | Cum | 3192.35 | 3192.35 | 0.12 | False | None | None | False | None | False | 383.082 | 0 |
3745242 | 139916 | None | code39 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. KPWD VOL-1 Item No. 2.11 ( a.) Page. No. 18 | Tonne | 95718.99 | 95718.99 | 2.88 | False | None | None | False | None | False | 275670.6912 | 0 |
3745243 | 139916 | None | code40 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of
machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8526.83 | 8526.83 | 41.68 | False | None | None | False | None | False | 355398.2744 | 0 |
3745244 | 139916 | None | code41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 257.87 | 257.87 | 55.56 | False | None | None | False | None | False | 14327.2572 | 0 |
3745245 | 139916 | None | code42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 396.97 | 396.97 | 369.34 | False | None | None | False | None | False | 146616.8998 | 0 |
3745246 | 139916 | None | code43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 106.0 | 106.0 | 70.02 | False | None | None | False | None | False | 7422.12 | 0 |
3745247 | 139916 | None | code44 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 115.56 | 115.56 | 55.56 | False | None | None | False | None | False | 6420.5136 | 0 |
3745248 | 139916 | None | code45 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 169.06 | 169.06 | 360.8 | False | None | None | False | None | False | 60996.848 | 0 |
3745249 | 139916 | None | code46 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kgs | 179.76 | 179.76 | 47.25 | False | None | None | False | None | False | 8493.66 | 0 |
3745250 | 139916 | None | code47 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brassProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and ot her sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. bras. | Kgs | 7205.38 | 7205.38 | 10.78 | False | None | None | False | None | False | 77673.9964 | 0 |
3745251 | 139916 | None | code48 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid
in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 1057.16 | 1057.16 | 2.25 | False | None | None | False | None | False | 2378.61 | 0 |
3745252 | 139916 | None | code49 | Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm | Sqm | 299.6 | 299.6 | 1.01 | False | None | None | False | None | False | 302.596 | 0 |
3745253 | 139916 | None | code50 | Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 105732.05 | 105732.05 | 0.1 | False | None | None | False | None | False | 10573.205 | 0 |
3745254 | 139916 | None | code51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1087.12 | 1087.12 | 1.0 | False | None | None | False | None | False | 1087.12 | 0 |
3745255 | 139916 | None | code52 | Providing and fixing in position Teak wood fully panelled shutters for windows with stiles and rails of 25mm. thick, 75mm wide in two halves with panels of 20mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6580.5 | 6580.5 | 3.12 | False | None | None | False | None | False | 20531.16 | 0 |
3745256 | 139916 | None | code53 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 123.05 | 123.05 | 2.25 | False | None | None | False | None | False | 276.8625 | 0 |
3745257 | 139916 | None | code54 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 147.66 | 147.66 | 3.78 | False | None | None | False | None | False | 558.1548 | 0 |
3745258 | 139916 | None | code55 | Providing and fixing on wall face unpasticised Rigid PVC rain water pipes conforming to ISI:13592 Type A including jointing with seal ring confroming to IS: 5382,leaving 10mm gap for thermal expansions, (i) single socked pipes 75mm diameter | Mtr | 197.0 | 197.0 | 26.04 | False | None | None | False | None | False | 5129.88 | 0 |
3745259 | 139916 | None | code56 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. | Sqm | 940.53 | 940.53 | 29.33 | False | None | None | False | None | False | 27585.7449 | 0 |
3745260 | 139916 | None | code57 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 113.0 | 113.0 | 83.15 | False | None | None | False | None | False | 9395.95 | 0 |
3745261 | 139916 | None | code58 | Supplying heavy gauge PVC conduit pipe ...2. mm dia.....25...mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Each | 81.0 | 81.0 | 200.0 | False | None | None | False | None | False | 16200.0 | 0 |
3745262 | 139916 | None | code59 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. | Each | 29.0 | 29.0 | 100.0 | False | None | None | False | None | False | 2900.0 | 0 |
3745263 | 139916 | None | code60 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for Each outlet.GROUP a)short point up to 3 mtr from tapping point out let via switch | Each | 269.0 | 269.0 | 6.0 | False | None | None | False | None | False | 1614.0 | 0 |
3745264 | 139916 | None | code61 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for Each outlet.GROUP a)short point up to 3 mtr from tapping point out let via switch Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Each | 379.0 | 379.0 | 10.0 | False | None | None | False | None | False | 3790.0 | 0 |
3745265 | 139916 | None | code62 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for Each outlet.GROUP a)short point up to 3 mtr from tapping point out let via switch long above 6 mtr up to 10 mtr from tapping point to out let via switch | Each | 555.0 | 555.0 | 77.0 | False | None | None | False | None | False | 42735.0 | 0 |
3745266 | 139916 | None | code63 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 | Each | 147.0 | 147.0 | 42.0 | False | None | None | False | None | False | 6174.0 | 0 |
3745267 | 139916 | None | code64 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | Each | 319.0 | 319.0 | 18.0 | False | None | None | False | None | False | 5742.0 | 0 |
3745268 | 139916 | None | code65 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
3745269 | 139916 | None | code66 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 module | Each | 284.0 | 284.0 | 13.0 | False | None | None | False | None | False | 3692.0 | 0 |
3745270 | 139916 | None | code67 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.12 module | Each | 344.0 | 344.0 | 18.0 | False | None | None | False | None | False | 6192.0 | 0 |
3745271 | 139916 | None | code68 | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. | Each | 3053.0 | 3053.0 | 1.0 | False | None | None | False | None | False | 3053.0 | 0 |
3745272 | 139916 | None | code69 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 amps SP | Each | 415.0 | 415.0 | 12.0 | False | None | None | False | None | False | 4980.0 | 0 |
3745273 | 139916 | None | code70 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 amps SP40 A TPN | Each | 3044.0 | 3044.0 | 1.0 | False | None | None | False | None | False | 3044.0 | 0 |
3745274 | 139916 | None | code71 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mm | Each | 42.0 | 42.0 | 550.0 | False | None | None | False | None | False | 23100.0 | 0 |
3745275 | 139916 | None | code72 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mm4.sq mm | Each | 63.0 | 63.0 | 150.0 | False | None | None | False | None | False | 9450.0 | 0 |
3745276 | 139916 | None | code73 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mm6 sq mm | Each | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 |
3745277 | 139916 | None | code74 | Supplying of box fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC
power supply excluding Tube. | Each | 340.0 | 340.0 | 57.0 | False | None | None | False | None | False | 19380.0 | 0 |
3745278 | 139916 | None | code75 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 57.0 | False | None | None | False | None | False | 6954.0 | 0 |
3745279 | 139916 | None | code76 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | Each | 2984.0 | 2984.0 | 36.0 | False | None | None | False | None | False | 107424.0 | 0 |
3745280 | 139916 | None | code77 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 36.0 | False | None | None | False | None | False | 6156.0 | 0 |
3745281 | 139916 | None | code78 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
3745282 | 139916 | None | code79 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch6/16A univarsal socket | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 |
3745283 | 139916 | None | code80 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch400 watts dimmer | Each | 276.0 | 276.0 | 36.0 | False | None | None | False | None | False | 9936.0 | 0 |
3745284 | 139916 | None | code81 | Supply of roundsquare recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70 lumen maintenance with CRI 80 Power Input:220 240V
@50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition | Each | 1324.0 | 1324.0 | 2.0 | False | None | None | False | None | False | 2648.0 | 0 |
3745285 | 139916 | None | code82 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipeto the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipeshall have 16 through holes of 12mm dia. | Each | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 |