createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723277044596
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3980.00
emd238378.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose22-08-2024 16:00:00
tenderQueryClose17-08-2024 16:00:00
technicalBidOpen26-08-2024 11:00:00
publishedDate12-08-2024 17:47:04
publishedByPostRDPR_EE_DIV_YDG
publishedByUserKPE10677 - PRAKASH KULKARNI
bidValidityPeriod90
noOfCalls1
preBidMeetingDate17-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPrakash Kulkarni
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448349742
tenderSupplierListNone
tenderSchedule
createdTs1723277044639
version12
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT7719
titleCONSTRUCTION OF NEW TOILET BLOCKS (MALE FEMALE), DESK, DESKTOP COMPUTER, OFFICE CHAIRS, ALMIRAH(OFFICE), FIRE AND SAFETY UNIT, LAB TABLE, CC TV CAMERA, 16 CHANNELS DVR WITH 4K, COMPUTER TABLE DISKING & SETTING, SANITARY NAPKINS INCINERATOR MACHINE, BIKE STAND AT GOVT. FIRST GRADE COLLEGE TO SHORAPUR TQ. DIST. YADGIR.
descriptionPACKAGE NO YDG-SRP-02 (3WORKS) CONSTRUCTION OF NEW TOILET BLOCKS (MALE & FEMALE), DESK, DESKTOP COMPUTER, OFFICE CHAIRS, ALMIRAH(OFFICE), FIRE AND SAFETY UNIT, LAB TABLE, CC TV CAMERA, 16 CHANNELS DVR WITH 4K, COMPUTER TABLE DISKING & SETTING, SANITARY NAPKINS INCINERATOR MACHINE, BIKE STAND AT GOVT. FIRST GRADE COLLEGE TO SHORAPUR TQ. DIST. YADGIR.
categoryWORKS
categoryTextWorks
ecv15891841.30
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location971
locationNameRDPR Division Office Yadagiri
provisionalAmount19042000.0
groupOverheadTotalNone
fileNumberAEE/PRESD/SRP/KKRDB/DEGREE-C-SHORAPUR-TOWN
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17232770450000NoneNoneBuildings2 PROVIDING S-TYPE REVOLVING CHAIR FOR COMPUTER LAB, CUSION CHAIRS, SOLAR POWER SYSTEM, STEEL TABLE WOODEN TOP, S-TYPE CHAIRS FOR PRINCIPAL CHAMBER AND OFFICE, PORTABLE DRINKING WATER FACILITY AND AIR CONDITIONER FOR COMPUTER LAB, PRINCIPAL CHAMBER, OFFICE AND STAF ROOM AT GOVT.FIRST DEGREE COLLEGE IN SHORAPUR TOWN TQ.SHORAPUR DIST.YADGIR2860992.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3744124139855NoneItem-01GeM Items SUPPLY S-TYPE REVOLVING CHAIR Unbranded Esd Chairs as per ANSI 520 20-2007 NA (KPESDCHAIRWA) COMPUTER LAB CHAIRSNo10000.010000.095.0FalseNoneNoneFalseNoneFalse950000.00
3744125139855NoneItem-02CUSION CHAIRS Chair Features Others Furniture Assembly Already Assembled Material Other Natural MaterialsNo3500.03500.022.0FalseNoneNoneFalseNoneFalse77000.00
3744126139855NoneItem-03SOLAR POWER SYSTEM;- Rated out put power of inverter (Kw) 5 Switching device IGBT No. of Phase (in Nos.) 3 Inverter output wave form Pure sine wave No.of MPPT per inverter (in Nos.) 2 No. of string at input side of inverter ( input port +ve and -ve) ( hint: 1 sets contains 1 +ve and 1 -ve port) 2 sets Maximum power point tracker Integrated in the PCU/inverter to maximize energy drawn from the array Operating Voltage Range of Inverter 80 to 500 V Over load support at Input side, DC 15% of Maximum Input Voltage PROUDCT ID : 5116877-40745498675No510000.0510000.02.0FalseNoneNoneFalseNoneFalse1020000.00
3744127139855NoneItem-04TABLE WOODEN TOP:- Storage one side Total Number of Storage Units single storage Table Top Material and Thickness (+/-2 mm) 20 mm thick MDF Board of grade SBG II conforming to IS 12406 laminated with minimum 0.6 mm thick on Top side of type S, P or F having index 3.2.3 conforming to IS 2046 and minimum 0.5 mm thick balancing laminate on the other side Padestal (Under structure) Mild Steel Square Section of outside side minimum 25 mm and wall thickness minimum 1.2 mm Table Top Length +/-10(mm) 1000 millimeter Table Top Width +/-10(mm) 470 millimeter Table Height +/-5(mm) 735 millimeter Storage Unit and Drawer Units Material 0.6 mm M S Sheet (Not as per IS 8126) PROUDCT ID : 5116877-41366975331No8800.08800.046.0FalseNoneNoneFalseNoneFalse404800.00
3744128139855NoneItem-05S-TYPE CHAIRS FOR PRINCIPAL CHAMBER Chair Type Non-Revolving and Non-Tilting chair with Armrest Chair frame type Cantilever Armrest type Moulded armrest continuously fitted with seat bottom to backrest Seat type Padded Backrest type Padded Frame Material Configuration One piece Frame material Steel tube (ERW quality) conforming to IS: 1161 (with latest Amendment) Seat material Moulded Plywood Seat material thickness 12 mm Density of Polyurethane foam used in seat (2 Kg/Cub Meter) 32 Seat upholstered with Fabric GSM of seat cover ( 3 GSM) N.A Backrest material Moulded PlywoodDensity of Polyurethane foam used in Backrest ( 2 Kg/Cub Meter) 32 PROUDCT ID 5116877 84745221188No12000.012000.012.0FalseNoneNoneFalseNoneFalse144000.00
3744129139855NoneItem-06PORTABLE DRINKING WATER FACILITY:- Type of purifier Without storage Number of filteration stages Two Type of main filtering cartridge Hollow Fibre MF (Micro Filtration) without Activated Carbon Filter Filtering Technology Suction Minimum Size of filtering particles (Microns) 0.3 micrometer Maximum filteration rate (Ltrs/min) 4 liter Life of Filtering cartridge (Ltrs) 100000 liter PROUDCT ID : 5116877-89494487571 PORTABLE DRINKING WATER FACILITYNo24500.024500.02.0FalseNoneNoneFalseNoneFalse49000.00
3744130139855NoneItem-07Supplying TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit 2 tone capacity 5 starEach54048.054048.04.0FalseNoneNoneFalseNoneFalse216192.00
17232770450000NoneNoneBuildings3 PROVIDING 5.5KV UPS WITH BATTERY, PRINTER MACHINE & XEROX AT GOVT.FIRST DEGREE COLLEGE IN SHORAPUR TOWN TQ.SHORAPUR DIST.YADGIR605940.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3744131139856NoneItem-015.5 KV UPS WITH BATTERY :Rating 5.5KVA Input Single phase 180V -260V, 50 Hz AC mains Output ( in invertor mode) AC Single phase 220V +/- 10 V, 50 Hz Inverter Efficiency Range (DC to AC) 70-75% Warranty for inverter (Years) 2 Battery/Backup Bank Provided ( Hint: In case the inverter is supplied with battery, seller shall ensure compliance to the GST Rates as per recommendations made in the 45th Meeting of GST council dated 17th Sep 2021 ) Yes (suitable battery bank provided) Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest, Stationary Cells and Batteries, Lead Acid type (with tubular positive plates) conforming to IS:1651:1991 latest AH Capacity of each Battery(Minimum) (hint: NA in case Battery not provided) 200 Warranty for battery (Years) by Battery Manufacturer/Brand hint: NA in case battery not provided 2 Suitable Trolley/ Rack for Battery Provided No PROUDCT ID : 5116877-44354303810No198390.0198390.02.0FalseNoneNoneFalseNoneFalse396780.00
3744132139856NoneItem-02PRINTER MACHINE:- Type of Machine Multifunction Machine Print Technology Laser Type of Printing Mono Cartridge Technology Separate Drum and Toner (Mono Component) Platen/Flatbed Size A4 Paper Size (Original/Image) A4/A4 RAM size (MB) 512 Hard Disk Capacity(GB) 0 Minimum Speed per Minute as per ISO/IEC 24734 in A4 Size-Mono 40 Minimum Speed per Minute as per ISO/IEC 24734 in A4 Size-Colour 0 Scanning Feature Availability Yes Duplexing Feature Availability Yes Faxing Feature Availability No Networking Feature Availability Yes Wi-Fi Availability No Original Document Feeder Type DADF/RADF Number of Main Paper Tray 1 Bypass Facility Yes On Site OEM Warranty (Year) 1 PROUDCT ID : 5116877-59103805555No33961.033961.03.0FalseNoneNoneFalseNoneFalse101883.00
3744133139856NoneItem-03XEROX MACHINE:- Type of Machine Multifunction Machine Print Technology Laser Type of Printing Mono Cartridge Technology Separate Drum and Toner (Mono Component) Platen/Flatbed Size A4 Paper Size (Original/Image) A4/A4 RAM size (MB) 512 Hard Disk Capacity(GB) 0 Minimum Speed per Minute as per ISO/IEC 24734 in A4 Size-Mono 40 Minimum Speed per Minute as per ISO/IEC 24734 in A4 Size-Colour 0 Scanning Feature Availability Yes Duplexing Feature Availability Yes Faxing Feature Availability No Networking Feature Availability Yes Wi-Fi Availability No Original Document Feeder Type DADF/RADF Number of Main Paper Tray 1 Bypass Facility Yes On Site OEM Warranty (Year) 1 PROUDCT ID : 5116877-12649719016No107277.0107277.01.0FalseNoneNoneFalseNoneFalse107277.00
17232770450000NoneNoneBuildings1 CONSTRUCTION OF NEW TOILET BLOCKS (MALE & FEMALE), DESK, DESKTOP COMPUTER, OFFICE CHAIRS, ALMIRAH(OFFICE), FIRE AND SAFETY UNIT, LAB TABLE, CC TV CAMERA, 16 CHANNELS DVR WITH 4K, COMPUTER TABLE DISKING & SETTING, SANITARY NAPKINS INCINERATOR MACHINE, BIKE STAND AT GOVT. FIRST GRADE COLLEGE TO SHORAPUR TQ. DIST. YADGIR.12424909.3
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3744134139857NoneItem-01New Toilet Block Femle : EARTHWORK FOR LOWERING & LEVELLING :- Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the workCum99.7599.757.93FalseNoneNoneFalseNoneFalse791.01750
3744135139857NoneItem-02EARTHWORK EXCAVATION:- Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.153.69FalseNoneNoneFalseNoneFalse5750.1990
3744136139857NoneItem-03EARTH FILLING AVAILABLE EXCAVATED EARTH:-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.316.11FalseNoneNoneFalseNoneFalse4499.5230
3744137139857NoneItem-04EARTH FILLING :-Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum474.0474.023.0FalseNoneNoneFalseNoneFalse10902.00
3744138139857NoneItem-05P/L P. C.C. BED M10:-Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8518.2FalseNoneNoneFalseNoneFalse118806.870
3744139139857NoneItem-06RCC WORKS M20:- Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Centering and shutteringCum7085.237085.236.08FalseNoneNoneFalseNoneFalse43078.19840
3744140139857NoneItem-07RCC WORKS M25 COLUMN UPTO PLINTH BOTTOM Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Centering and shutteringCum11152.6811152.680.62FalseNoneNoneFalseNoneFalse6914.66160
3744141139857NoneItem-08RCC WORKS M20: -Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM RCC WORKS M20 BEAMS CENTERING Appendix I Corrigendum-3 Additionalities for Formwork, Centering & ScaffoldingCum10622.6410622.643.93FalseNoneNoneFalseNoneFalse41746.97520
3744142139857NoneItem-09Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Centering and shuttering COLUMN RCC WORKS M25 Above Plinth Beam to Bottom of Roof SlabCum11286.5611286.561.63FalseNoneNoneFalseNoneFalse18397.09280
3744143139857NoneItem-10Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Centering and shuttering COLUMN RCC WORKS M25 LINTEL BEAM RCC WORKS M25Cum10622.6410622.646.19FalseNoneNoneFalseNoneFalse65754.14160
3744144139857NoneItem-11Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Centering and shuttering ROOF BEAM RCC WORKS M25Cum10622.6410622.641.97FalseNoneNoneFalseNoneFalse20926.60080
3744145139857NoneItem-12Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Centering and shuttering ROOF SLABCum9958.739958.736.55FalseNoneNoneFalseNoneFalse65229.68150
3744146139857NoneItem-13MASONRY WORKS UCRS STONE MASONRY(FOUNDATION): Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) UCRS upto Plinth Beam BottomCum5891.555891.5515.65FalseNoneNoneFalseNoneFalse92202.75750
3744147139857NoneItem-14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Toilet Block Outer WallsCum8367.458367.4517.29FalseNoneNoneFalseNoneFalse144673.21050
3744148139857NoneItem-15HALF MASONRY WORKS (PARTITION WALL):-Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. Toilet Block Internal wallsSqm1117.051117.0545.65FalseNoneNoneFalseNoneFalse50993.33250
3744149139857NoneItem-16PLASTERING WORKS CEILING PLASTER:- Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.1543.65FalseNoneNoneFalseNoneFalse14803.89750
3744150139857NoneItem-17PLASTERING INSIDE :- Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.25169.65FalseNoneNoneFalseNoneFalse68581.01250
3744151139857NoneItem-18OUTSIDE PLASTERING :-Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.25126.69FalseNoneNoneFalseNoneFalse51214.43250
3744152139857NoneItem-19WOOD WORK , DOOR FRAMES : Providing sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.05FalseNoneNoneFalseNoneFalse5187.78750
3744153139857NoneItem-20WPC DOOR SHUTTER :Providing & fixing factory made 100% carpenry friendly ready to use single soild plain WPC flush shutter of 35mm thk. Which is anti termite & having high water absorption propoertySqm3816.753816.752.52FalseNoneNoneFalseNoneFalse9618.210
3744154139857NoneItem-21FIXING OF DOOR FRAMES: -Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsNos1066.81066.81.0FalseNoneNoneFalseNoneFalse1066.80
3744155139857NoneItem-22WPC DOOR FRAMES Providing & fixing factory made single excuted WPC solid door/window frame of size 62 x 125 Page No.111 Item no. 12.93.2 KPWD. Volumn -2 DSR 2023-24Mtr802.2802.234.5FalseNoneNoneFalseNoneFalse27675.90
3744156139857NoneItem-23WPC DOOR SHUTTER :- Providing & fixing factory made 100% carpenry friendly ready to use single soild plain WPC flush shutter of 35mm thk. Which is anti termite & having high water absorption propoertySqm3364.23364.29.77FalseNoneNoneFalseNoneFalse32868.2340
3744157139857NoneItem-24STEEL GLAZED VENTILATORS:- Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Kg155.4155.4157.5FalseNoneNoneFalseNoneFalse24475.50
3744158139857NoneItem-25GLASS TO VENTILATORS:- Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm957.6957.67.5FalseNoneNoneFalseNoneFalse7182.00
3744159139857NoneItem-26ANTISKID TILES :-Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1308.31308.340.42FalseNoneNoneFalseNoneFalse52881.4860
3744160139857NoneItem-27TILES CLADDING:- Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile coarse sand) with Acid and alkali resistant tileSqm1323.01323.063.53FalseNoneNoneFalseNoneFalse84050.190
3744161139857NoneItem-28FINISHING WORK PAINTING TO STEEL PRIMER :-Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm52.552.515.0FalseNoneNoneFalseNoneFalse787.50
3744162139857NoneItem-29PAINTING TO STEEL ENAMEL PAINT:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm145.95145.9515.0FalseNoneNoneFalseNoneFalse2189.250
3744163139857NoneItem-30INSIDE PAINTING:Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer'sspecification. Two coats on new work to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and asper directions of Engineer-in-charge. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm139.65139.65106.12FalseNoneNoneFalseNoneFalse14819.6580
3744164139857NoneItem-31CEILING PAINT:- Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer'sspecification. Two coats on new work to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and asper directions of Engineer-in-charge. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm139.65139.6543.65FalseNoneNoneFalseNoneFalse6095.72250
3744165139857NoneItem-32OUTSIDE PAINTING:- Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm186.9186.9126.69FalseNoneNoneFalseNoneFalse23678.3610
3744166139857NoneItem-33T.M.T STEEL:- Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne93929.8593929.853.15FalseNoneNoneFalseNoneFalse295879.02750
3744167139857NoneItem-34WATER PROOF TREATMENT:- Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm857.85857.8543.65FalseNoneNoneFalseNoneFalse37445.15250
3744168139857NoneItem-35WATER SUPPLY and sanitary for Gound floor: WORKS:- Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. Internal work, Conceled work, including cutting chases & making good the wall etc 15mm dia pipe in GF WCMtr324.45324.4530.0FalseNoneNoneFalseNoneFalse9733.50
3744169139857NoneItem-36Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 25 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL 25 mm dia pipe from borewell to terrace tankMtr333.9333.950.0FalseNoneNoneFalseNoneFalse16695.00
3744170139857NoneItem-37Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 32 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL 25mm dia pipe from terrace tank TO GFMtr333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3744171139857NoneItem-38P/F PTMT BIBCOCK:- Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gNos165.9165.914.0FalseNoneNoneFalseNoneFalse2322.60
3744172139857NoneItem-39P/F PTMT STOPCOCK CONCEALED:- Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gmsNos211.05211.057.0FalseNoneNoneFalseNoneFalse1477.350
3744173139857NoneItem-40P/F BRASS BALL VALVE :- Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) : INLET & OUTLET POINTSNos576.45576.454.0FalseNoneNoneFalseNoneFalse2305.80
3744174139857NoneItem-41P/F WASH BASIN:- Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.Unit2410.82410.83.0FalseNoneNoneFalseNoneFalse7232.40
3744175139857NoneItem-42PTMT STOP COCK :- 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gmsNos329.7329.73.0FalseNoneNoneFalseNoneFalse989.10
3744176139857NoneItem-43PVC CONNECTION PIPE:- Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length Wash Basins Brass UnionsUnit95.5595.5515.0FalseNoneNoneFalseNoneFalse1433.250
3744177139857NoneItem-44FLEXIBLE TUBE ( WATER FOSSET):- Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.Each285.6285.66.0FalseNoneNoneFalseNoneFalse1713.60
3744178139857NoneItem-45P/F MIRROR WITH FRAME :- Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Unit1281.01281.03.0FalseNoneNoneFalseNoneFalse3843.00
3744179139857NoneItem-46SANITARY WORK: SQUATTING PLATE INDIAN TYPE: Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsPan5128.25128.24.0FalseNoneNoneFalseNoneFalse20512.80
3744180139857NoneItem-47WATER CLOSET EUROPEAN TYPE:-Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Pan6275.856275.852.0FalseNoneNoneFalseNoneFalse12551.70
3744181139857NoneItem-48WASTE PIPE:- Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm diaEach96.696.63.0FalseNoneNoneFalseNoneFalse289.80
3744182139857NoneItem-49Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushin cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two squatting plates with 5 litre P.V.C. automatic flushin cisternEach13590.1513590.154.0FalseNoneNoneFalseNoneFalse54360.60
3744183139857NoneItem-50Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth For Inspection chamber 0.9x0.9x0.5x9no'sCum313.95313.9575.65FalseNoneNoneFalseNoneFalse23750.31750
3744184139857NoneItem-51BRICK MASONRY FOR INSPECTION CHAMBER: Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Inspection Chamber of Size 600 x 600 x 600 mm 0.6*3*.23*9no.Cum8367.458367.453.75FalseNoneNoneFalseNoneFalse31377.93750
3744185139857NoneItem-52PLASTERING FOR INSPECTION CHAMBER:- Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Inspection Chamber inside & outside (0.6*5 + .83*4)* 9no.Sqm404.25404.2556.88FalseNoneNoneFalseNoneFalse22993.740
3744186139857NoneItem-53SLAB OVER INSPECTION CHAMBER:- Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. Inspection Chamber 830MM X 830 MM x 9nos.Sqm974.4974.46.2FalseNoneNoneFalseNoneFalse6041.280
3744187139857NoneItem-54WATER STOAGE TANK:- KSRB 13-11.1 : Providing and placing on terrace,(at all floor levels) polyethylene water storage tank is:12701 marked with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.- WATER TANK 2000 ltrLtr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3744188139857NoneItem-55UPVC PIPE:- Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. 110mm dia FROM Urinals/WC roomsMtr302.4302.430.0FalseNoneNoneFalseNoneFalse9072.00
3744189139857NoneItem-56Stainless Steel Grab Bar Steel Hande Size (48" Inchs)Rft300.0300.04.0FalseNoneNoneFalseNoneFalse1200.00
3744190139857NoneItem-57Electrical Work : -Supplying heavy gauge PVC conduit pipe ...2. mm dia.....25...mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickRmtr81.081.030.0FalseNoneNoneFalseNoneFalse2430.00
3744191139857NoneItem-58Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. up to 50 mmRmtr29.029.010.0FalseNoneNoneFalseNoneFalse290.00
3744192139857NoneItem-59Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP short point up to 3 mtr from tapping point out let via switchEach269.0269.04.0FalseNoneNoneFalseNoneFalse1076.00
3744193139857NoneItem-60Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchEach379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
3744194139857NoneItem-61long above 6 mtr up to 10 mtr from tapping point to out let via switchEach555.0555.01.0FalseNoneNoneFalseNoneFalse555.00
3744195139857NoneItem-62Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6 amps 3/5 wayEach147.0147.01.0FalseNoneNoneFalseNoneFalse147.00
3744196139857NoneItem-63Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 wayEach319.0319.01.0FalseNoneNoneFalseNoneFalse319.00
3744197139857NoneItem-64Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 wayEach177.0177.05.0FalseNoneNoneFalseNoneFalse885.00
3744198139857NoneItem-65Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 moduleEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3744199139857NoneItem-66Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 12 moduleEach344.0344.01.0FalseNoneNoneFalseNoneFalse344.00
3744200139857NoneItem-67Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SP & NEach1492.01492.01.0FalseNoneNoneFalseNoneFalse1492.00
3744201139857NoneItem-68Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 amps SPEach415.0415.03.0FalseNoneNoneFalseNoneFalse1245.00
3744202139857NoneItem-69Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 6-32 A DPEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3744203139857NoneItem-70Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mmRmtr42.042.030.0FalseNoneNoneFalseNoneFalse1260.00
3744204139857NoneItem-71Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 4. sq mmRmtr63.063.050.0FalseNoneNoneFalseNoneFalse3150.00
3744205139857NoneItem-72Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each122.0122.03.0FalseNoneNoneFalseNoneFalse366.00
3744206139857NoneItem-73Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 12 sweep (300 mm)Each2969.02969.08.0FalseNoneNoneFalseNoneFalse23752.00
3744207139857NoneItem-74Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each492.0492.08.0FalseNoneNoneFalseNoneFalse3936.00
3744208139857NoneItem-75PROVIDING AND FIXING OF TRAP: Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 8 10 mm inlet and 100 mm outlet * Sand cast Iron S&S as per IS: 1729Each1202.251202.253.0FalseNoneNoneFalseNoneFalse3606.750
3744209139857NoneItem-76Borewell : -Geophysical investigation :-Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry borewell towords yeild test etc and completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3744210139857NoneItem-77Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete Borewell depth of 0 to 50 mMtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3744211139857NoneItem-78Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete Borewell depth Borewell depth of 50 to 100 mMtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3744212139857NoneItem-79Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete Borewell depth Borewell depth of 100 to 150 mMtr517.65517.6550.0FalseNoneNoneFalseNoneFalse25882.50
3744213139857NoneItem-80SUPPLY & FIXING MS CASE:- Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutyMtr2029.652029.6518.0FalseNoneNoneFalseNoneFalse36533.70
3744214139857NoneItem-81PVC FILTER PIPE:- Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: 10.1.9 PVC pipes 160mm dia., 6 kg/sqcm & class 3 m 618Mtr648.9648.9150.0FalseNoneNoneFalseNoneFalse97335.00
3744215139857NoneItem-82Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :Mtr492.45492.45150.0FalseNoneNoneFalseNoneFalse73867.50
3744216139857NoneItem-83SUBMERSIBLE PUMPL -Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00”Each29518.6529518.651.0FalseNoneNoneFalseNoneFalse29518.650
3744217139857NoneItem-84PVC CABLE:- Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2Mtr89.2589.25175.0FalseNoneNoneFalseNoneFalse15618.750
3744218139857NoneItem-85STARTER:- Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta StarterEach10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3744219139857NoneItem-86Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clauseJob3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3744220139857NoneItem-87NON RETURN VALVE:- Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mmEach1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3744221139857NoneItem-88New Toilet Block Male :-EARTHWORK FOR LOWERING & LEVELLING :- Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the workCum99.7599.757.93FalseNoneNoneFalseNoneFalse791.01750
3744222139857NoneItem-89EARTHWORK EXCAVATION:- Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.153.69FalseNoneNoneFalseNoneFalse5750.1990
3744223139857NoneItem-90EARTH FILLING AVAILABLE EXCAVATED EARTH:-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.316.11FalseNoneNoneFalseNoneFalse4499.5230
3744224139857NoneItem-91EARTH FILLING :-Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.723.0FalseNoneNoneFalseNoneFalse11447.10
3744225139857NoneItem-92P/L P. C.C. BED M10:-Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8518.2FalseNoneNoneFalseNoneFalse118806.870
3744226139857NoneItem-93RCC WORKS M20:- Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates CENTERING TO FOOTING: -FOOTING CENTERING Appendix I Additionalities for Formwork, Centering & ScaffoldingCum7085.237085.236.08FalseNoneNoneFalseNoneFalse43078.19840
3744227139857NoneItem-94Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC WORKS M25 COLUMN UPTO PLINTH BOTTOM Lvl COLUMNS CENTERING Appendix I Corrigendum-3 Additionalities for Formwork, Centering & Scaffolding Columns Upto Plinth Beam Botoom rcc Qty Sub StructureCum11152.6811152.680.62FalseNoneNoneFalseNoneFalse6914.66160
3744228139857NoneItem-95RCC WORKS M20: -Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM RCC WORKS M20 and CENTERING TO PLINTH BEAMS :PLINTH BEAMS CENTERING Appendix I Corrigendum-3 Additionalities for Formwork, Centering & ScaffoldingCum10622.6410622.642.87FalseNoneNoneFalseNoneFalse30486.97680
3744229139857NoneItem-96Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates COLUMN RCC WORKS M25 Above Plinth Beam to Bottom of Roof Slab COLUMNS CENTERING Appendix I Additionalities for Formwork, Centering Scaffolding Columns Above Plinth Beam to Bottom Roof Slab Qty Super StructureCum11286.5611286.561.63FalseNoneNoneFalseNoneFalse18397.09280
3744230139857NoneItem-97Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LINTEL BEAM RCC WORKS M25 CENTERING TO LINTEL BEAM :BEAMS CENTERING Appendix I Additionalities for Formwork, Centering & ScaffoldingCum10622.6410622.644.32FalseNoneNoneFalseNoneFalse45889.80480
3744231139857NoneItem-98Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM RCC WORKS M25 CENTERING TO ROOF BEAMS:- PLINTH BEAMS CENTERING Appendix I Corrigendum-3 Additionalities for Formwork, Centering & ScaffoldingCum10622.6410622.641.97FalseNoneNoneFalseNoneFalse20926.60080
3744232139857NoneItem-99Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF SLAB CENTERING TO ROOF SLAB:- ROOF SLAB CENTERING Appendix I Additionalities for Formwork, Centering & ScaffoldingCum9958.739958.736.55FalseNoneNoneFalseNoneFalse65229.68150
3744233139857NoneItem-100MASONRY WORKS UCRS STONE MASONRY(FOUNDATION): Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) UCRS upto Plinth Beam BottomCum5891.555891.5515.65FalseNoneNoneFalseNoneFalse92202.75750
3744234139857NoneItem-101Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Toilet Block Outer WallsCum8367.458367.4517.29FalseNoneNoneFalseNoneFalse144673.21050
3744235139857NoneItem-102HALF MASONRY WORKS (PARTITION WALL):-Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. Toilet Block Internal wallsSqm1117.051117.0532.69FalseNoneNoneFalseNoneFalse36516.36450
3744236139857NoneItem-103PLASTERING WORKS CEILING PLASTER:- Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.1543.65FalseNoneNoneFalseNoneFalse14803.89750
3744237139857NoneItem-104PLASTERING INSIDE :- Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.25140.54FalseNoneNoneFalseNoneFalse56813.2950
3744238139857NoneItem-105OUTSIDE PLASTERING :-Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.25126.69FalseNoneNoneFalseNoneFalse51214.43250
3744239139857NoneItem-106Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum128518.95128518.950.05FalseNoneNoneFalseNoneFalse6425.94750
3744240139857NoneItem-107WPC DOOR SHUTTER :Providing & fixing factory made 100% carpenry friendly ready to use single soild plain WPC flush shutter of 35mm thk. Which is anti termite & having high water absorption propoertySqm3816.753816.752.52FalseNoneNoneFalseNoneFalse9618.210
3744241139857NoneItem-108FIXING OF DOOR FRAMES: -Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsNos1066.81066.81.0FalseNoneNoneFalseNoneFalse1066.80
3744242139857NoneItem-109WPC DOOR FRAMES Providing & fixing factory made single excuted WPC solid door/window frame of size 62 x 125 Page No.111 Item no. 12.93.2 KPWD. Volumn -2 DSR 2023-24Mtr802.2802.223.1FalseNoneNoneFalseNoneFalse18530.820
3744243139857NoneItem-110WPC DOOR SHUTTER :- Providing & fixing factory made 100% carpenry friendly ready to use single soild plain WPC flush shutter of 35mm thk. Which is anti termite & having high water absorption propoertySqm3364.23364.26.62FalseNoneNoneFalseNoneFalse22271.0040
3744244139857NoneItem-111STEEL GLAZED VENTILATORS:- Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Kg155.4155.4157.5FalseNoneNoneFalseNoneFalse24475.50
3744245139857NoneItem-112GLASS TO VENTILATORS:- Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm957.6957.67.5FalseNoneNoneFalseNoneFalse7182.00
3744246139857NoneItem-113ANTISKID TILES :-Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1308.31308.340.95FalseNoneNoneFalseNoneFalse53574.8850
3744247139857NoneItem-114TILES CLADDING:- Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile coarse sand) with Acid and alkali resistant tileSqm1323.01323.057.75FalseNoneNoneFalseNoneFalse76403.250
3744248139857NoneItem-115FINISHING WORK PAINTING TO STEEL PRIMER :-Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm52.552.515.0FalseNoneNoneFalseNoneFalse787.50
3744249139857NoneItem-116PAINTING TO STEEL ENAMEL PAINT:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm145.95145.9515.0FalseNoneNoneFalseNoneFalse2189.250
3744250139857NoneItem-117INSIDE PAINTING:Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer'sspecification. Two coats on new work to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and asper directions of Engineer-in-charge. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm139.65139.6582.79FalseNoneNoneFalseNoneFalse11561.62350
3744251139857NoneItem-118CEILING PAINT:- Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer'sspecification. Two coats on new work to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and asper directions of Engineer-in-charge. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm139.65139.6543.65FalseNoneNoneFalseNoneFalse6095.72250
3744252139857NoneItem-119OUTSIDE PAINTING:- Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm186.9186.9126.69FalseNoneNoneFalseNoneFalse23678.3610
3744253139857NoneItem-120T.M.T STEEL:- Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne93929.8593929.852.87FalseNoneNoneFalseNoneFalse269578.66950
3744254139857NoneItem-121WATER PROOF TREATMENT:- Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm857.85857.8543.65FalseNoneNoneFalseNoneFalse37445.15250
3744255139857NoneItem-122GROUND FLOOR : WATER SUPPLY WORKS:- Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. Internal work, Conceled work, including cutting chases & making good the wall etc 15mm dia pipe in GF WCMtr324.45324.4530.0FalseNoneNoneFalseNoneFalse9733.50
3744256139857NoneItem-123Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 25 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL 25 mm dia pipe from borewell to terrace tankMtr333.9333.950.0FalseNoneNoneFalseNoneFalse16695.00
3744257139857NoneItem-124Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 32 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL 25mm dia pipe from terrace tank TO GFMtr333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3744258139857NoneItem-125P/F PTMT BIBCOCK:- Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gNos165.9165.914.0FalseNoneNoneFalseNoneFalse2322.60
3744259139857NoneItem-126P/F PTMT STOPCOCK CONCEALED:- Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gmsNos211.05211.057.0FalseNoneNoneFalseNoneFalse1477.350
3744260139857NoneItem-127P/F BRASS BALL VALVE :- Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) : INLET & OUTLET POINTSNos576.45576.454.0FalseNoneNoneFalseNoneFalse2305.80
3744261139857NoneItem-128P/F WASH BASIN:- Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.Unit2410.82410.83.0FalseNoneNoneFalseNoneFalse7232.40
3744262139857NoneItem-129PTMT STOP COCK :- 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gmsNos329.7329.73.0FalseNoneNoneFalseNoneFalse989.10
3744263139857NoneItem-130PVC CONNECTION PIPE:- Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length Wash Basins Brass UnionsUnit95.5595.5515.0FalseNoneNoneFalseNoneFalse1433.250
3744264139857NoneItem-131FLEXIBLE TUBE ( WATER FOSSET):- Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.Each285.6285.66.0FalseNoneNoneFalseNoneFalse1713.60
3744265139857NoneItem-132P/F MIRROR WITH FRAME :- Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Unit1281.01281.03.0FalseNoneNoneFalseNoneFalse3843.00
3744266139857NoneItem-133SANITARY WORK: SQUATTING PLATE INDIAN TYPE: Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsPan5128.25128.24.0FalseNoneNoneFalseNoneFalse20512.80
3744267139857NoneItem-134WATER CLOSET EUROPEAN TYPE:-Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Pan6275.856275.852.0FalseNoneNoneFalseNoneFalse12551.70
3744268139857NoneItem-135WASTE PIPE:- Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm diaEach96.696.63.0FalseNoneNoneFalseNoneFalse289.80
3744269139857NoneItem-136Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushin cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two squatting plates with 5 litre P.V.C. automatic flushin cisternEach13590.1513590.154.0FalseNoneNoneFalseNoneFalse54360.60
3744270139857NoneItem-137Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushin cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach13590.1513590.151.0FalseNoneNoneFalseNoneFalse13590.150
3744271139857NoneItem-138Providing and fixing granite stone slab with table rubbed, edges roundedand polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm2928.452928.458.1FalseNoneNoneFalseNoneFalse23720.4450
3744272139857NoneItem-139Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth For Inspection chamber 0.9x0.9x0.5x9no'sCum313.95313.9575.65FalseNoneNoneFalseNoneFalse23750.31750
3744273139857NoneItem-140BRICK MASONRY FOR INSPECTION CHAMBER: Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Inspection Chamber of Size 600 x 600 x 600 mm 0.6*3*.23*9no.Cum8080.88080.83.73FalseNoneNoneFalseNoneFalse30141.3840
3744274139857NoneItem-141PLASTERING FOR INSPECTION CHAMBER:- Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Inspection Chamber inside & outside (0.6*5 + .83*4)* 9no.Sqm404.25404.2556.88FalseNoneNoneFalseNoneFalse22993.740
3744275139857NoneItem-142SLAB OVER INSPECTION CHAMBER:- Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. Inspection Chamber 830MM X 830 MM x 9nos.Sqm974.4974.46.2FalseNoneNoneFalseNoneFalse6041.280
3744276139857NoneItem-143WATER STOAGE TANK:- KSRB 13-11.1 : Providing and placing on terrace,(at all floor levels) polyethylene water storage tank is:12701 marked with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.- WATER TANK 2000 ltrLtr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3744277139857NoneItem-144UPVC PIPE:- Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. 110mm dia FROM Urinals/WC roomsMtr302.4302.430.0FalseNoneNoneFalseNoneFalse9072.00
3744278139857NoneItem-145Stainless Steel Grab Bar Steel Hande Size (48" Inchs)Rft300.0300.04.0FalseNoneNoneFalseNoneFalse1200.00
3744279139857NoneItem-146PROVIDING AND FIXING OF TRAP: Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 8 10 mm inlet and 100 mm outlet * Sand cast Iron S&S as per IS: 1729Each1202.251202.254.0FalseNoneNoneFalseNoneFalse4809.00
3744280139857NoneItem-147Electrical Work : -Supplying heavy gauge PVC conduit pipe ...2. mm dia.....25...mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickRmtr81.081.030.0FalseNoneNoneFalseNoneFalse2430.00
3744281139857NoneItem-148Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. up to 50 mmRmtr29.029.010.0FalseNoneNoneFalseNoneFalse290.00
3744282139857NoneItem-149Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP short point up to 3 mtr from tapping point out let via switchEach269.0269.04.0FalseNoneNoneFalseNoneFalse1076.00
3744283139857NoneItem-150Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchEach379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
3744284139857NoneItem-151long above 6 mtr up to 10 mtr from tapping point to out let via switchEach555.0555.01.0FalseNoneNoneFalseNoneFalse555.00
3744285139857NoneItem-152Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6 amps 3/5 wayEach147.0147.01.0FalseNoneNoneFalseNoneFalse147.00
3744286139857NoneItem-153Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 wayEach319.0319.01.0FalseNoneNoneFalseNoneFalse319.00
3744287139857NoneItem-154Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 wayEach177.0177.05.0FalseNoneNoneFalseNoneFalse885.00
3744288139857NoneItem-155Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 moduleEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3744289139857NoneItem-156Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 12 moduleEach344.0344.01.0FalseNoneNoneFalseNoneFalse344.00
3744290139857NoneItem-157Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SP & NEach1854.01854.01.0FalseNoneNoneFalseNoneFalse1854.00
3744291139857NoneItem-158Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 amps SPEach415.0415.03.0FalseNoneNoneFalseNoneFalse1245.00
3744292139857NoneItem-159Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 6-32 A DPEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3744293139857NoneItem-160Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mmRmtr42.042.030.0FalseNoneNoneFalseNoneFalse1260.00
3744294139857NoneItem-161Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 4. sq mmRmtr63.063.050.0FalseNoneNoneFalseNoneFalse3150.00
3744295139857NoneItem-162Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each122.0122.03.0FalseNoneNoneFalseNoneFalse366.00
3744296139857NoneItem-163Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 12 sweep (300 mm)Each2969.02969.06.0FalseNoneNoneFalseNoneFalse17814.00
3744297139857NoneItem-164Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each492.0492.06.0FalseNoneNoneFalseNoneFalse2952.00
3744298139857NoneItem-165Borewell : Geophysical investigation :-Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry borewell towords yeild test etc and completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3744299139857NoneItem-166Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete Borewell depth of 0 to 50 mMtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3744300139857NoneItem-167Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete Borewell depth of 50 to 100 mMtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3744301139857NoneItem-168Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete Borewell depth of 100 to 150 mMtr517.65517.6550.0FalseNoneNoneFalseNoneFalse25882.50
3744302139857NoneItem-169SUPPLY & FIXING MS CASE:- Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutyMtr2029.652029.6518.0FalseNoneNoneFalseNoneFalse36533.70
3744303139857NoneItem-170PVC FILTER PIPE:- Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: 10.1.9 PVC pipes 160mm dia., 6 kg/sqcm & class 3 m 618Mtr648.9648.9150.0FalseNoneNoneFalseNoneFalse97335.00
3744304139857NoneItem-171Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :Mtr492.45492.45150.0FalseNoneNoneFalseNoneFalse73867.50
3744305139857NoneItem-172SUBMERSIBLE PUMPL -Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00”Each29518.6529518.651.0FalseNoneNoneFalseNoneFalse29518.650
3744306139857NoneItem-173PVC CABLE:- Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2Mtr89.2589.25175.0FalseNoneNoneFalseNoneFalse15618.750
3744307139857NoneItem-174STARTER:- Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta StarterEach10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3744308139857NoneItem-175Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clauseJob3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3744309139857NoneItem-176NON RETURN VALVE:- Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 65 mmEach1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3744310139857NoneItem-177Septic Tank & Soak Pit: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.173.48FalseNoneNoneFalseNoneFalse7869.7080
3744311139857NoneItem-178Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water,all materials,usage& all other appurtenaces required to complete the workCum497.7497.75.9FalseNoneNoneFalseNoneFalse2936.430
3744312139857NoneItem-179Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.859.44FalseNoneNoneFalseNoneFalse61622.9040
3744313139857NoneItem-180Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6652.86652.86.36FalseNoneNoneFalseNoneFalse42311.8080
3744314139857NoneItem-181Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum3326.43326.46.36FalseNoneNoneFalseNoneFalse21155.9040
3744315139857NoneItem-182Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.850.5FalseNoneNoneFalseNoneFalse46964.9250
3744316139857NoneItem-183Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum9094.059094.0518.18FalseNoneNoneFalseNoneFalse165329.8290
3744317139857NoneItem-184Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm450.45450.45126.6FalseNoneNoneFalseNoneFalse57026.970
3744318139857NoneItem-185Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipesMtr610.05610.0530.0FalseNoneNoneFalseNoneFalse18301.50
3744319139857NoneItem-186Supplying and fixing SFRC frame and cover conforming to IS 12592 (part I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete Medium DutyNo2009.72009.72.0FalseNoneNoneFalseNoneFalse4019.40
3744320139857NoneItem-187Gound Floor: Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work Page No.8 Item No. 1.12 KPWD. Volumn -1 DSR 2023-24Cum96.696.631.92FalseNoneNoneFalseNoneFalse3083.4720
3744321139857NoneItem-188Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Page No.8 Item No. 1.14 KPWD. Volumn -1 DSR 2023-24Cum107.1107.115.1FalseNoneNoneFalseNoneFalse1617.210
3744322139857NoneItem-189Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Page No. 7 Item No. 1.8 KPWD. Volumn -1 DSR 2023-24Cum422.1422.131.92FalseNoneNoneFalseNoneFalse13473.4320
3744323139857NoneItem-190Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Page No.15 Item No. 2.1.4 KPWD. Volumn -1 DSR 2023-24Cum6527.856527.8529.8FalseNoneNoneFalseNoneFalse194529.930
3744324139857NoneItem-191Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg154.35154.351814.28FalseNoneNoneFalseNoneFalse280034.1180
3744325139857NoneItem-192Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should haveSqm922.95922.95200.64FalseNoneNoneFalseNoneFalse185180.6880
3744326139857NoneItem-193DESKTOP COMPUTER:- Processor Make Intel Processor Generation 10 Number of Cores per Processor 6 Processor Description Intel Core i5 Processor Number Intel Core i5 10400 Chipset Series Intel H Series Chipset Number Intel H510 Operating System (Factory Pre-Loaded) Windows 10 Professional RAM Size (GB) 16 RAM Expandability up to( using spare DIMM Slots in GB) 64 Type of Drives used to populate the Internal Bays SSD Total HDD Capacity (GB) 0 Total SSD Capacity (GB) 512 Total SSHD Capacity in addition to 8 GB Flash (GB) 0 Cabinet Form Factor Tower (13.1 to 26 Litres) Monitor Technology IPS LED Backlit Monitor Size (INCHES) 23.8 Monitor Resolution (PIXELS) 1920x1080 On Site OEM Warranty (Year) 3No85000.085000.036.0FalseNoneNoneFalseNoneFalse3060000.00
3744327139857NoneItem-194Officce chairs: CRN Craft Non-Revolving and Non-Tilting chair with Armrest CRN CraftR (CRN-J-U10)No3000.03000.0100.0FalseNoneNoneFalseNoneFalse300000.00
3744328139857NoneItem-195ALMIRAH (OFFICE):- FURNHARDT Almirah Steel shelving cabinet with partial wardrobe (ALMARI STEEL (100MM X 900MM X480MM))No19875.019875.017.0FalseNoneNoneFalseNoneFalse337875.00
3744329139857NoneItem-196ALMIRAH (LIBRARY):- Unbranded Steel Bookcase having 2 Doors and cam lever lock with common keyNo20000.020000.017.0FalseNoneNoneFalseNoneFalse340000.00
3744330139857NoneItem-197FIRE AND SAFETY UNIT (Firestop Portable Fire Extinguishers ) Firestop Portable Fire Extinguishers as per IS 15683 (2018) High Pressure Extinguisher (Service Pressure 19 bar) Foam Based (as per IS 4989) Class -BNo10000.010000.019.0FalseNoneNoneFalseNoneFalse190000.00
3744331139857NoneItem-198LAB Table:- Unbranded Laboratory Steel Furniture Side bench with rack and table top NANo26500.026500.010.0FalseNoneNoneFalseNoneFalse265000.00
3744332139857NoneItem-199CC TV CAMERA:- ewit 2MP BULLET CAMERA ewitR (EW-HD2420B)No5000.05000.020.0FalseNoneNoneFalseNoneFalse100000.00
3744333139857NoneItem-20016 Channels DVR with 4K Type of Recorder DVR Total Number of Input Channels 16 Maximum Recording Resolution supported 4K (3840 2160) Recording Speed for all channels (fps) Upto 6 Hard Disks Provided Yes (inclusive in the scope of supply) Total Storage Capacity (TB) of the hard disk provided 16 valid BIS certificate as per IS 13252 under CSR Yes required) (Warranty 1year)No100000.0100000.02.0FalseNoneNoneFalseNoneFalse200000.00
3744334139857NoneItem-201COMPUTER TABLE:- Mahalaxmi 1370 millimeter X 760 millimeter (mm LxD) Executive Computer Table MahalaxmiR (mct-887)No11500.011500.036.0FalseNoneNoneFalseNoneFalse414000.00
3744335139857NoneItem-202COMPUTER LAB CHAIRS:- Unbranded Esd Chairs as per ANSI 520 20-2007 NA (KPESDCHAIRWA)No10000.010000.036.0FalseNoneNoneFalseNoneFalse360000.00
3744336139857NoneItem-203DESKING & SEATING:- ALWIN Three seater classroom desking drawing ALWINR (Bapl/Classroom Desk Bench/02)No13000.013000.0125.0FalseNoneNoneFalseNoneFalse1625000.00
3744337139857NoneItem-204Sanitary Napkins Incinetator Machine:-ViKTRON Sanitary Napkins Incinetator Machine with Smoke Control Unit ViKTRONR (IS/VIK/INCIN/15-50(1-15)/0051)No18000.018000.01.0FalseNoneNoneFalseNoneFalse18000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17232770450000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17232770450000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17232770450000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17232770450000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17232770450000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17232770880000NoneNoneELIGIBILITYFinancial bids of the technically qualified bidders only will be openedNone
17232770970000NoneNoneELIGIBILITYRight of acceptance or rejection of any or all tenders with or without any reasons is reserved with the undersigned or any concerned higher officers of the DepartmentNone
17232771040000NoneNoneELIGIBILITYConditional tender will not be ConsideredNone
17232771110000NoneNoneELIGIBILITYTender processing amount will not be refundableNone
17232771190000NoneNoneELIGIBILITYContractors should have to upload the scan copy of all necessary qualification documents, and submit the original documents certificates while tender opening evaluation for verificationNone
17232771270000NoneNoneELIGIBILITYThe Photos and Video graphs should be taken before commencement, during execution and after completion of the work in presence of nodal officersNone
17232771350000NoneNoneELIGIBILITYThe liquidated damage for whole of the works are Rs. 0.10 percent per day the maximum amount of liquidated damages for the whole of works is 10 percent of final contract priceNone
17232771420000NoneNoneELIGIBILITYThe agency shall furnish affidavit stating that existing commitments furnished by him are true. If found falls action shall be taken as per lawNone
17232771520000NoneNoneELIGIBILITYThe bidder shall bear all costs associated with the preparation and submission of each tender and the employer will in no case be responsible and liable for those costs. The department is not responsible for any delay in accessing e-procurement portalNone
17232771620000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD 300 LET 2006 Bangalore Dated 01/01/2007 and Government Letter No.PW 134 BMS 2007 Dated 27/7/2007 a sum amounting to 1 percent of the bill amount will be deducted towards Construction Labour Welfare fundNone
17232771690000NoneNoneELIGIBILITYThe Item Rates quoted shall include cost of Royalty charges on construction materials and other taxes as per the prevailing Government Orders at the time of execution and including cost and conveyance of all materials, curing, loading and unloading, with all leads and lifts, labour, hire charges of all machineries and equipments and all incidental charges etc complete necessary for completion of work. All the Items shall be executed as directed by the Engineer-in-charge of the workNone
17232771770000NoneNoneELIGIBILITYThe field laboratory shall preferably locate, adjacent to the site with the required amenity as per the clauseNone
17232771850000NoneNoneELIGIBILITYSelf declaration of machineries are not acceptedNone
17232771930000NoneNoneELIGIBILITYThe work should be completed within the stipulated period from the date of agreement and The date of agreement itself is the date of commencement of the workNone
17232772010000NoneNoneELIGIBILITYThird party inspection is mandatory for all the works in this programmeNone
17232772090000NoneNoneELIGIBILITYThe Tenderer shall obtain the work done certificate in the prescribed form from the competent authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate / Certificates shall be produced whenever requiredNone
17232772160000NoneNoneELIGIBILITYExecutive Engineer has authority to accept or reject any tender without assigning reasonNone
17232772230000NoneNoneELIGIBILITYTenderer must submit his present accurate postal address and phone / cell phone numberNone
17232772310000NoneNoneELIGIBILITYFor interpretations of clauses, conditions, spelling mistakes, etc., decision of Executive Engineer, is finalNone
17232772400000NoneNoneELIGIBILITYThe bidder must submit 5 years Profit and loss account obtained from Chartered Accountant (CA) Only. General Category Bidders must have annual contract turn over for 2 years not less than amount put to tenderNone
17232772480000NoneNoneELIGIBILITYThe Furnished E.M.D. will be released only after successfully execution of the Tender Agreement by the successful Tenderer or bid validity days from the date of submission of Tender whichever is earlierNone
17232772560000NoneNoneELIGIBILITYBefore tendering for the works the tenderer may inspect the site personallyNone
17232772660000NoneNoneELIGIBILITYThe successful tenderer shall maintain the work during the defect liability period of 12 months from the date of completion of the workNone
17232772740000NoneNoneELIGIBILITYThe Tenderer shall have valid KPWD licenseNone
17232772830000NoneNoneELIGIBILITYOther details and instructions shall be seen and fallowed as per the bidding documents KWNone
17232772920000NoneNoneELIGIBILITYThe Road / Building constructed under this programme shall be of high standard, requiring no major repairs for 1 years, The contractor shall furnish performance guarantee for 1 years as per clause and the performance guarantee will be released only after 1 years after completion of workNone
17232773000000NoneNoneELIGIBILITYIf Unnecessary documents uploaded by the bidder then tender will be directly rejected and further correspondence will not be entertained declaration should be uploaded on bidders letter head duly signedNone
17232773090001NoneNoneELIGIBILITYThe work should be completed within 11 months including mansoonNone
17232773170000NoneNoneELIGIBILITYThe Bidder should not quote above amount put to tenderNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNone3.To qualify for award of this contract, Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily completed, as a prime contractor, for at least one similar work of value not less than Rs. 79.46 Lakhs attach certificate by not below rank of Executive Engineer with Indent No. from e-Procurement Portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNone4.To qualify for award of this contract, Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily executed quantities of works in any one year for continues period of 12 months 80 percent of tendered Quantity 1. Earthwork and Embankment 332.57. Cum 2. PCC RCC 104.77 3. UCR BBM 100.37 Cum 4. Plastering 667.48 Sqm 5. Flooring 129.78 Sqm. 6. Steel 5.22 M.TonnePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNone1.The Tenderer shall have valid class -III KPWD LicenceCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNone7.Name of the Equipment Machineries All machinery Documents are RC Book will be verified from E Vahan website if not found valid then bid will be rejected Tenderer should further demonstrate Owned Machineries This clause is Exempted upto 300 lakh Estimate costCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Machineries
NoneNoneNoneNone2.To qualify for award of this contract, Each tenderer in its name should have in the last five year 2019-20 to 2023-24 Achieved in at least Two financial years an average annual financial turnover not less than in all classes of civil engineering construction works only of Rs. 317.84 Lakhs. Attach certificated from C.A. on Letter Head Two times amount put to tender. with UDIN No. otherwise bid will be directly disqualifiedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNone5.Line of credit Rs. 43.34 Lakhs should be enclosed in prescribed formatFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNone6.Bid Capacity on Letter of the contractorOthers6.Bid Capacity on Letter of the contractor
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- 6.Bid Capacity on Letter of the contractor
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
1.The Tenderer shall have valid class -III KPWD LicenceTrueTechnical Bid
2.To qualify for award of this contract, Each tenderer in its name should have in the last five year 2019-20 to 2023-24 Achieved in at least Two financial years an average annual financial turnover not less than in all classes of civil engineering construction works only of Rs. 317.84 Lakhs. Attach certificated from C.A. on Letter Head Two times amount put to tender. with UDIN No. otherwise bid will be directly disqualifiedTrueTechnical Bid
3.To qualify for award of this contract, Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily completed, as a prime contractor, for at least one similar work of value not less than Rs. 79.46 Lakhs attach certificate by not below rank of Executive Engineer with Indent No. from e-Procurement Portal.TrueTechnical Bid
4.To qualify for award of this contract, Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily executed quantities of works in any one year for continues period of 12 months 80 percent of tendered Quantity 1. Earthwork and Embankment 332.57. Cum 2. PCC RCC 104.77 3. UCR BBM 100.37 Cum 4. Plastering 667.48 Sqm 5. Flooring 129.78 Sqm. 6. Steel 5.22 M.TonneTrueTechnical Bid
5.Line of credit Rs. 43.34 Lakhs should be enclosed in prescribed formatTrueTechnical Bid
6.Bid Capacity on Letter of the contractorTrueTechnical Bid
7.Name of the Equipment Machineries All machinery Documents are RC Book will be verified from E Vahan website if not found valid then bid will be rejected Tenderer should further demonstrate Owned Machineries This clause is Exempted upto 300 lakh Estimate costTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1723446392000
version0
createdDateNone
modifiedDateNone
blockNumberExecutive Engineer, P.R.E. Division, Yadgir Opp NVM Hotel, Station Road, Yadgir
streetNone
cityYADGIR
stateKarnataka
pin585202
tenderRecallDTONone