createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723275523529
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3990.00
emd239070.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose22-08-2024 16:00:00
tenderQueryClose17-08-2024 16:00:00
technicalBidOpen26-08-2024 11:00:00
publishedDate12-08-2024 17:46:06
publishedByPostRDPR_EE_DIV_YDG
publishedByUserKPE10677 - PRAKASH KULKARNI
bidValidityPeriod90
noOfCalls1
preBidMeetingDate17-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPrakash Kulkarni
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448349742
tenderSupplierListNone
tenderSchedule
createdTs1723275523567
version16
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT7685
titlePACKAGE NO. KKRDB-YDG-SRP-01 CONSTRUCTION OF LIBRARY & LABS WITH AUDITORUM HALL AT GOVT. FIRST GRADE DEGREE COLLEGE IN KEMBHAVI TOWN TQ.SHORPUR DIST.YADGIR.
descriptionPACKAGE NO. KKRDB-YDG-SRP-01 CONSTRUCTION OF LIBRARY & LABS WITH AUDITORUM HALL AT GOVT. FIRST GRADE DEGREE COLLEGE IN KEMBHAVI TOWN TQ.SHORPUR DIST.YADGIR.
categoryWORKS
categoryTextWorks
ecv15937869.19
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location971
locationNameRDPR Division Office Yadagiri
provisionalAmount19000000.0
groupOverheadTotalNone
fileNumberAEE/PRESD/SRP/KKRDB/DEGREE-C-KEMBHAVI
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17232755240000NoneNoneBuildingsPACKAGE NO. KKRDB-YDG-SPR-01 CONSTRUCTION OF LIBRARY & LABS WITH AUDITORUM HALL AT GOVT. FIRST GRADE DEGREE COLLEGE IN KAMBHAVI TOWN IN SHORAPUR TQ.12438164.79
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3743776139838NoneItem01Ground Floor Civil Work : Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.1568.1FalseNoneNoneFalseNoneFalse60843.510
3743777139838NoneItem02Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3450.01FalseNoneNoneFalseNoneFalse125687.7930
3743778139838NoneItem03Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water,all materials,usage& all other appurtenaces required to complete the workCum497.7497.7303.42FalseNoneNoneFalseNoneFalse151012.1340
3743779139838NoneItem04Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.5532.56FalseNoneNoneFalseNoneFalse191828.8680
3743780139838NoneItem05Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.916.28FalseNoneNoneFalseNoneFalse113128.0920
3743781139838NoneItem06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8569.15FalseNoneNoneFalseNoneFalse451400.82750
3743782139838NoneItem07Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6652.86652.890.12FalseNoneNoneFalseNoneFalse599550.3360
3743783139838NoneItem08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications . (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateCum7185.157185.15122.59FalseNoneNoneFalseNoneFalse880827.53850
3743784139838NoneItem09Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum532.22532.2266.03FalseNoneNoneFalseNoneFalse35142.48660
3743785139838NoneItem10Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum3326.43326.415.32FalseNoneNoneFalseNoneFalse50960.4480
3743786139838NoneItem11Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum4656.964656.968.78FalseNoneNoneFalseNoneFalse40888.10880
3743787139838NoneItem12Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum5029.615029.6113.3FalseNoneNoneFalseNoneFalse66893.8130
3743788139838NoneItem13Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum4311.094311.0926.37FalseNoneNoneFalseNoneFalse113683.44330
3743789139838NoneItem14Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum3592.583592.5876.63FalseNoneNoneFalseNoneFalse275299.40540
3743790139838NoneItem15Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum4331.094331.095.0FalseNoneNoneFalseNoneFalse21655.450
3743791139838NoneItem16Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum3233.323233.321.28FalseNoneNoneFalseNoneFalse4138.64960
3743792139838NoneItem17Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.8526.08FalseNoneNoneFalseNoneFalse2449690.4880
3743793139838NoneItem18Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8367.458367.4584.53FalseNoneNoneFalseNoneFalse707300.54850
3743794139838NoneItem19Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm253.05253.05642.96FalseNoneNoneFalseNoneFalse162701.0280
3743795139838NoneItem20Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.55509.58FalseNoneNoneFalseNoneFalse198506.8890
3743796139838NoneItem21Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm105.0105.01051.66FalseNoneNoneFalseNoneFalse110424.30
3743797139838NoneItem22Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1233.751233.75443.22FalseNoneNoneFalseNoneFalse546822.6750
3743798139838NoneItem23Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1231.651231.6551.61FalseNoneNoneFalseNoneFalse63565.45650
3743799139838NoneItem24Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm163.8163.8642.96FalseNoneNoneFalseNoneFalse105316.8480
3743800139838NoneItem25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm143.85143.85452.08FalseNoneNoneFalseNoneFalse65031.7080
3743801139838NoneItem26Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.9509.58FalseNoneNoneFalseNoneFalse84539.3220
3743802139838NoneItem27Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg176.4176.4954.45FalseNoneNoneFalseNoneFalse168364.980
3743803139838NoneItem28Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg176.4176.445.0FalseNoneNoneFalseNoneFalse7938.00
3743804139838NoneItem29Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.Kg144.9144.9107.17FalseNoneNoneFalseNoneFalse15528.9330
3743805139838NoneItem30Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..Sqm5482.055482.0519.85FalseNoneNoneFalseNoneFalse108818.69250
3743806139838NoneItem31Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brassProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and ot her sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. bras.Kg599.55599.55140.12FalseNoneNoneFalseNoneFalse84008.9460
3743807139838NoneItem32Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm1037.41037.429.25FalseNoneNoneFalseNoneFalse30343.950
3743808139838NoneItem33Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mmSqm651.0651.013.07FalseNoneNoneFalseNoneFalse8508.570
3743809139838NoneItem34Providing & fixing of Aluminium Ventilators of frame size 40 x 18 mm of 1.3 mm thick, 0.933 Kg/ m all aluminium sections including cutting to required length, joints mitred subdiving the frame tenonned and riveted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs or teak wood gatties including supply along with fixing of SS - 304 mesh with necessary required materials etc., complete.Sqm3339.03339.017.55FalseNoneNoneFalseNoneFalse58599.450
3743810139838NoneItem35Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specificationsCum103755.75103755.750.72FalseNoneNoneFalseNoneFalse74704.140
3743811139838NoneItem36Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1066.81066.88.0FalseNoneNoneFalseNoneFalse8534.40
3743812139838NoneItem37Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm6457.56457.524.88FalseNoneNoneFalseNoneFalse160662.60
3743813139838NoneItem38Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm120.75120.7565.3FalseNoneNoneFalseNoneFalse7884.9750
3743814139838NoneItem39Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.9144.946.08FalseNoneNoneFalseNoneFalse6676.9920
3743815139838NoneItem40Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6590.026590.027.89FalseNoneNoneFalseNoneFalse51995.25780
3743816139838NoneItem41Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications . (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregateCum7253.587253.5842.99FalseNoneNoneFalseNoneFalse311831.40420
3743817139838NoneItem42CENTERING WORK (FIXING & REMOVING )Cum7253.587253.5813.69FalseNoneNoneFalseNoneFalse99301.51020
3743818139838NoneItem43Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum4352.154352.156.4FalseNoneNoneFalseNoneFalse27853.760
3743819139838NoneItem44Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum3626.793626.7918.1FalseNoneNoneFalseNoneFalse65644.8990
3743820139838NoneItem45Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum4352.154352.153.52FalseNoneNoneFalseNoneFalse15319.5680
3743821139838NoneItem46Providing centering,shuttering,formwork,scaffolding,etc, Finished rate of concrete work iof buildingCum3264.113264.111.28FalseNoneNoneFalseNoneFalse4178.06080
3743822139838NoneItem47Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. KPWD VOL-1 Item No. 2.11 ( a.) Page. No. 18Tonne94824.4294824.427.11FalseNoneNoneFalseNoneFalse674201.62620
3743823139838NoneItem48Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8447.148447.14127.1FalseNoneNoneFalseNoneFalse1073631.4940
3743824139838NoneItem49Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm255.46255.46556.69FalseNoneNoneFalseNoneFalse142212.02740
3743825139838NoneItem50Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm221.55221.5531.96FalseNoneNoneFalseNoneFalse7080.7380
3743826139838NoneItem51Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm393.26393.26664.8FalseNoneNoneFalseNoneFalse261439.2480
3743827139838NoneItem52Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm106.0106.0495.09FalseNoneNoneFalseNoneFalse52479.540
3743828139838NoneItem53Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1245.51245.5412.59FalseNoneNoneFalseNoneFalse513880.8450
3743829139838NoneItem54Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1243.381243.3821.28FalseNoneNoneFalseNoneFalse26459.12640
3743830139838NoneItem55Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., completeSqm1129.81129.85.76FalseNoneNoneFalseNoneFalse6507.6480
3743831139838NoneItem56Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1535.941535.9419.66FalseNoneNoneFalseNoneFalse30196.58040
3743832139838NoneItem57Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg178.08178.08631.26FalseNoneNoneFalseNoneFalse112414.78080
3743833139838NoneItem58Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg178.08178.0845.0FalseNoneNoneFalseNoneFalse8013.60
3743834139838NoneItem59Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.Kg146.28146.28107.17FalseNoneNoneFalseNoneFalse15676.82760
3743835139838NoneItem60Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm4496.524496.521.89FalseNoneNoneFalseNoneFalse8498.42280
3743836139838NoneItem61Electricla Works: Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (25mm dia 2mm thick)Mtr78.078.0306.0FalseNoneNoneFalseNoneFalse23868.00
3743837139838NoneItem62Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (25mm dia 2mm thick)Mtr79.079.0135.0FalseNoneNoneFalseNoneFalse10665.00
3743838139838NoneItem63Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering,finishing upto wall surface complete.Upto 50 mm conduit in brick wall (25mm dia 2mm thick)Mtr29.029.0135.0FalseNoneNoneFalseNoneFalse3915.00
3743839139838NoneItem64Supplying and fixing PVC/metal conduit Deep junction box (25mm dia 2mm thick)Each56.056.063.0FalseNoneNoneFalseNoneFalse3528.00
3743840139838NoneItem65Supplying And Fixing Metal Fan Box with Round Hook..No117.0117.030.0FalseNoneNoneFalseNoneFalse3510.00
3743841139838NoneItem66Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switchEach394.0394.0103.0FalseNoneNoneFalseNoneFalse40582.00
3743842139838NoneItem67Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (1.0 Sq.mm)Mtr19.019.02025.0FalseNoneNoneFalseNoneFalse38475.00
3743843139838NoneItem68Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (1.5 Sq.mm)Mtr26.026.0758.0FalseNoneNoneFalseNoneFalse19708.00
3743844139838NoneItem69Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (2.5 Sq.mm)Mtr42.042.0505.0FalseNoneNoneFalseNoneFalse21210.00
3743845139838NoneItem70Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (4.0 Sq.mm)Mtr63.063.025.0FalseNoneNoneFalseNoneFalse1575.00
3743846139838NoneItem71Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (6 Way)Each220.0220.05.0FalseNoneNoneFalseNoneFalse1100.00
3743847139838NoneItem72Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (8 Way)Each261.0261.025.0FalseNoneNoneFalseNoneFalse6525.00
3743848139838NoneItem73Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box (6 Way)Each234.0234.05.0FalseNoneNoneFalseNoneFalse1170.00
3743849139838NoneItem74Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box (8 Way)Each284.0284.025.0FalseNoneNoneFalseNoneFalse7100.00
3743850139838NoneItem75Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (6A One Way Switchs)Each102.0102.0192.0FalseNoneNoneFalseNoneFalse19584.00
3743851139838NoneItem76Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (6A Three Way socket)Each171.0171.019.0FalseNoneNoneFalseNoneFalse3249.00
3743852139838NoneItem77Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (Stepped Fan Regulator Two Modul)Each357.0357.020.0FalseNoneNoneFalseNoneFalse7140.00
3743853139838NoneItem78Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (6/16A Universal Socket)Each236.0236.019.0FalseNoneNoneFalseNoneFalse4484.00
3743854139838NoneItem79Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (TV/Telephone Socket)Each156.0156.04.0FalseNoneNoneFalseNoneFalse624.00
3743855139838NoneItem80Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Ceiling FanEach2984.02984.020.0FalseNoneNoneFalseNoneFalse59680.00
3743856139838NoneItem81Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input: 220-240V 50 60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (LED light fitting 1 x 4 - 20/22 W) No690.0690.059.0FalseNoneNoneFalseNoneFalse40710.00
3743857139838NoneItem82Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. ( 6-32- A DP )Each739.0739.040.0FalseNoneNoneFalseNoneFalse29560.00
3743858139838NoneItem83Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.. ( 8 Way SP & N )No1492.01492.05.0FalseNoneNoneFalseNoneFalse7460.00
3743859139838NoneItem84Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board.. ( 32-40 A 2 pole )No4559.04559.05.0FalseNoneNoneFalseNoneFalse22795.00
3743860139838NoneItem85Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. . ( 63A 2 pole )No5258.05258.05.0FalseNoneNoneFalseNoneFalse26290.00
3743861139838NoneItem86Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete (250 A 4 x 30 x 10 mm Aluminium Strip )Mtr3435.03435.05.0FalseNoneNoneFalseNoneFalse17175.00
3743862139838NoneItem87Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy (Digital Meter)No9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
3743863139838NoneItem88Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS 694:2010 (6C x 6 mm2)Mtr328.0328.050.0FalseNoneNoneFalseNoneFalse16400.00
3743864139838NoneItem89Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( 35 to 95 Sqmm)Mtr23647.023647.02.0FalseNoneNoneFalseNoneFalse47294.00
3743865139838NoneItem90Road type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified Bentonite clay slurry for earthing in 50 Kg BagBag368.0368.05.0FalseNoneNoneFalseNoneFalse1840.00
3743866139838NoneItem91Supplying and laying double walled corrugated(DWC) HDPE pipe including all necessary connecting sockets/couplings/Tees/Bends/End-caps of same materials in existing trench as per IS 14930 part-II suitable for drawing underMtr154.02154.02100.0FalseNoneNoneFalseNoneFalse15402.00
17232755240000NoneNoneBuildings2 CONSTRUCTION OF LIBRARY & LABS WITH AUDITORIUM HALL FIRST FLOOR (CONTINUATION WORK) AT GOVT.FIRST GRADE DEGREE COLLEGE IN KEMBHAVI TOWN TQ.SHORPUR DIST.YADGIR.2863573.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3743867139839NoneItem01PAINT INTERNAL WALLS:-Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.36165.36521.01FalseNoneNoneFalseNoneFalse86154.21360
3743868139839NoneItem02Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm145.22145.2260.35FalseNoneNoneFalseNoneFalse8764.0270
3743869139839NoneItem03Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm167.48167.48739.37FalseNoneNoneFalseNoneFalse123829.68760
3743870139839NoneItem04Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..Sqm5534.265534.2610.4FalseNoneNoneFalseNoneFalse57556.3040
3743871139839NoneItem05Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.Sqm931.74931.74513.39FalseNoneNoneFalseNoneFalse478345.99860
3743872139839NoneItem06Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings.0.63 mm thick with zinc coating not less than 275 g/m²Mtr677.34677.3424.8FalseNoneNoneFalseNoneFalse16798.0320
3743873139839NoneItem07Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg119.78119.787713.1FalseNoneNoneFalseNoneFalse923875.1180
3743874139839NoneItem08Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brassProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and ot her sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. bras.Kg616.92616.92140.12FalseNoneNoneFalseNoneFalse86442.83040
3743875139839NoneItem09Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm1047.251047.2547.25FalseNoneNoneFalseNoneFalse49482.56250
3743876139839NoneItem10Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mmSqm657.2657.213.07FalseNoneNoneFalseNoneFalse8589.6040
3743877139839NoneItem11Providing & fixing of Aluminium Ventilators of frame size 40 x 18 mm of 1.3 mm thick, 0.933 Kg/ m all aluminium sections including cutting to required length, joints mitred subdiving the frame tenonned and riveted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs or teak wood gatties including supply along with fixing of SS - 304 mesh with necessary required materials etc., complete.Sqm3370.83370.82.43FalseNoneNoneFalseNoneFalse8191.0440
3743878139839NoneItem12Providing and Fixing Factory made single extruded wood polymer composite (WPC) solid door/ window clerestory windowsframe/ chowkhat of frame size : 65x100mmMtr736.7736.720.3FalseNoneNoneFalseNoneFalse14955.010
3743879139839NoneItem13Providing & fixing factory made 100% carpenry friendly ready to use single soild plain WPC flush shutter of35mm thk. Which is anti termite & having high water absorption propoerty .The cost including cost of material ,transportation,labour and fixing chargeSqm3686.683686.687.94FalseNoneNoneFalseNoneFalse29272.23920
3743880139839NoneItem14Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specificationsCum105208.18105208.180.11FalseNoneNoneFalseNoneFalse11572.89980
3743881139839NoneItem15Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1076.961076.961.0FalseNoneNoneFalseNoneFalse1076.960
3743882139839NoneItem16Providing and fixing in position Teak wood fully panelled shutters for windows with stiles and rails of 25mm. thick, 75mm wide in two halves with panels of 20mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7310.827310.824.67FalseNoneNoneFalseNoneFalse34141.52940
3743883139839NoneItem17Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm121.9121.9203.64FalseNoneNoneFalseNoneFalse24823.7160
3743884139839NoneItem18Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm146.28146.288.64FalseNoneNoneFalseNoneFalse1263.85920
3743885139839NoneItem19Electricla Works: Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (25mm dia 2mm thick)Mtr78.078.052.0FalseNoneNoneFalseNoneFalse4056.00
3743886139839NoneItem20Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an interval of700mm using NF screws. (25mm dia 2mm thick)Mtr78.078.0297.0FalseNoneNoneFalseNoneFalse23166.00
3743887139839NoneItem21Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (25mm dia 2mm thick)Mtr79.079.0144.0FalseNoneNoneFalseNoneFalse11376.00
3743888139839NoneItem22Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering,finishing upto wall surface complete.Upto 50 mm conduit in brick wall (25mm dia 2mm thick)Mtr28.028.0144.0FalseNoneNoneFalseNoneFalse4032.00
3743889139839NoneItem23Supplying and fixing PVC/metal conduit Deep junction box (25mm dia 2mm thick)Each56.056.078.0FalseNoneNoneFalseNoneFalse4368.00
3743890139839NoneItem24Supplying And Fixing Metal Fan Box with Round Hook..No117.0117.030.0FalseNoneNoneFalseNoneFalse3510.00
3743891139839NoneItem25Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switchEach394.0394.0108.0FalseNoneNoneFalseNoneFalse42552.00
3743892139839NoneItem26Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (1.0 Sq.mm)Mtr19.019.02588.0FalseNoneNoneFalseNoneFalse49172.00
3743893139839NoneItem27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (1.5 Sq.mm)Mtr26.026.0776.0FalseNoneNoneFalseNoneFalse20176.00
3743894139839NoneItem28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (2.5 Sq.mm)Mtr42.042.0518.0FalseNoneNoneFalseNoneFalse21756.00
3743895139839NoneItem29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (4.0 Sq.mm)Mtr63.063.026.0FalseNoneNoneFalseNoneFalse1638.00
3743896139839NoneItem30Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (6 Way)Each220.0220.05.0FalseNoneNoneFalseNoneFalse1100.00
3743897139839NoneItem31Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (8 Way)Each261.0261.019.0FalseNoneNoneFalseNoneFalse4959.00
3743898139839NoneItem32Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box (6 Way)Each234.0234.05.0FalseNoneNoneFalseNoneFalse1170.00
3743899139839NoneItem33Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box (8 Way)Each284.0284.019.0FalseNoneNoneFalseNoneFalse5396.00
3743900139839NoneItem34Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (6A One Way Switchs)Each102.0102.0169.0FalseNoneNoneFalseNoneFalse17238.00
3743901139839NoneItem35Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (6A Three Way socket)Each171.0171.013.0FalseNoneNoneFalseNoneFalse2223.00
3743902139839NoneItem36Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (Stepped Fan Regulator Two Modul)Each357.0357.030.0FalseNoneNoneFalseNoneFalse10710.00
3743903139839NoneItem37Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (6/16A Universal Socket)Each236.0236.013.0FalseNoneNoneFalseNoneFalse3068.00
3743904139839NoneItem38Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (TV/Telephone Socket)Each156.0156.02.0FalseNoneNoneFalseNoneFalse312.00
3743905139839NoneItem39Supplying exhaust fan of 1440 RPM of 300 mm (12") size withbracket blades complete for light duty suitable to operate on230V 50Hz, AC Supply.Each1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
3743906139839NoneItem40Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Ceiling FanEach2984.02984.020.0FalseNoneNoneFalseNoneFalse59680.00
3743907139839NoneItem41Supplying of .feet -PVC Batten with integrated LED tube ..W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input: 220-240V50/60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defectworking under standard electrical condition. (LED light fitting 1 x 4' - 20/22 W)No690.0690.047.0FalseNoneNoneFalseNoneFalse32430.00
3743908139839NoneItem42Supplying & fixing of retrofit type LED bulb .W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.No269.0269.02.0FalseNoneNoneFalseNoneFalse538.00
3743909139839NoneItem43Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. ( 6-32- A DP )Each739.0739.024.0FalseNoneNoneFalseNoneFalse17736.00
3743910139839NoneItem44Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.. ( 8 Way SP & N )No1492.01492.03.0FalseNoneNoneFalseNoneFalse4476.00
3743911139839NoneItem45Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board.. ( 32-40 A 2 pole )No4559.04559.03.0FalseNoneNoneFalseNoneFalse13677.00
3743912139839NoneItem46Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. . ( 63A 2 pole )No5258.05258.03.0FalseNoneNoneFalseNoneFalse15774.00
3743913139839NoneItem47First Floor Plumbin work Water Supply : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching,refilling & testing of joints complete as per directions of Engineer in Charge. External work 32mm nominal dia pipesMtr372.0372.070.0FalseNoneNoneFalseNoneFalse26040.00
3743914139839NoneItem48Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching,refilling & testing of joints complete as per directions of Engineer in Charge. External work 25mm nominal dia pipesMtr296.0296.020.0FalseNoneNoneFalseNoneFalse5920.00
3743915139839NoneItem49Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931Nos635.0635.06.0FalseNoneNoneFalseNoneFalse3810.00
3743916139839NoneItem50Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.Nos725.0725.06.0FalseNoneNoneFalseNoneFalse4350.00
3743917139839NoneItem51Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos620.0620.03.0FalseNoneNoneFalseNoneFalse1860.00
3743918139839NoneItem52Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos332.0332.03.0FalseNoneNoneFalseNoneFalse996.00
3743919139839NoneItem53Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore HorizontalNos809.0809.02.0FalseNoneNoneFalseNoneFalse1618.00
3743920139839NoneItem54Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore VerticalNos925.0925.02.0FalseNoneNoneFalseNoneFalse1850.00
3743921139839NoneItem55Providing and fixing unplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal boreNos83.083.02.0FalseNoneNoneFalseNoneFalse166.00
3743922139839NoneItem56Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (CSR,2023-24, VOL-2 1st issue rates Item no.12-2-13.34)Ltr9.09.01000.0FalseNoneNoneFalseNoneFalse9000.00
3743923139839NoneItem57Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lidNos4838.04838.02.0FalseNoneNoneFalseNoneFalse9676.00
3743924139839NoneItem58Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerNos3082.03082.02.0FalseNoneNoneFalseNoneFalse6164.00
3743925139839NoneItem59Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm diaNos92.092.02.0FalseNoneNoneFalseNoneFalse184.00
3743926139839NoneItem60Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Oval shape 450x350 mm (outer dimensions)Nos1066.01066.02.0FalseNoneNoneFalseNoneFalse2132.00
3743927139839NoneItem61Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos100.0100.06.0FalseNoneNoneFalseNoneFalse600.00
3743928139839NoneItem62Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: For pipes SN4, 200mm dia.Mtr809.0809.072.0FalseNoneNoneFalseNoneFalse58248.00
3743929139839NoneItem63Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: For pipes SN4, 110mm dia.Mtr288.0288.024.0FalseNoneNoneFalseNoneFalse6912.00
3743930139839NoneItem64Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 75mm dia., 6 kg/sqcm & class 3Mtr220.0220.014.0FalseNoneNoneFalseNoneFalse3080.00
3743931139839NoneItem65Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Nos5454.05454.06.0FalseNoneNoneFalseNoneFalse32724.00
3743932139839NoneItem66Supplying and fixing SFRC frame and cover conforming to IS 12592 (part I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete Medium DutyNos1766.01766.06.0FalseNoneNoneFalseNoneFalse10596.00
3743933139839NoneItem67Providing and fixing on wall face unpasticised Rigid PVC rain water pipes conforming to ISI:13592 Type A including jointing with seal ring confroming to IS: 5382,leaving 10mm gap for thermal expansions, (i) single socked pipes 75mm diameterMtr197.0197.042.0FalseNoneNoneFalseNoneFalse8274.00
3743934139839NoneItem68Water Proff Treatment : -Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Page No. 149 Item no. 15.1 KPWD. Volumn -2 DSR 2023-24No866.02866.02180.0FalseNoneNoneFalseNoneFalse155883.60
3743935139839NoneItem69EXISTING PHYSICS LAB : Civil work : Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Sqm190.05190.0533.79FalseNoneNoneFalseNoneFalse6421.78950
3743936139839NoneItem70Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.19.59FalseNoneNoneFalseNoneFalse1027.0890
3743937139839NoneItem71Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.72.86FalseNoneNoneFalseNoneFalse1423.4220
3743938139839NoneItem72Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.556.39FalseNoneNoneFalseNoneFalse37647.00450
3743939139839NoneItem73Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.855.51FalseNoneNoneFalseNoneFalse35968.45350
3743940139839NoneItem74Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.91.15FalseNoneNoneFalseNoneFalse9633.4350
3743941139839NoneItem75Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.2533.63FalseNoneNoneFalseNoneFalse54556.26750
3743942139839NoneItem76Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1231.651231.6518.19FalseNoneNoneFalseNoneFalse22403.71350
17232755240000NoneNoneBuildings3 PROVIDING ELECTRIFICATION WORKS OF EXISTING FIRST FLOOR AND PHYSICS LAB AT GOVT. FIRST GRADE DEGREE COLLEGE IN KEMBHAVI TOWN Q.SHORPUR DIST.YADGIR636131.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3743943139840NoneItem01FIRST FLOOR ELECTRIFICATION WORK : -Supplying heavy gauge PVC conduit pipe 2 mm dia.25.mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickRmtr81.081.0320.0FalseNoneNoneFalseNoneFalse25920.00
3743944139840NoneItem02Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. up to 50 mmRmtr29.029.0220.0FalseNoneNoneFalseNoneFalse6380.00
3743945139840NoneItem03Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP short point up to 3 mtr from tapping point out let via switchEach269.0269.025.0FalseNoneNoneFalseNoneFalse6725.00
3743946139840NoneItem04Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchEach379.0379.030.0FalseNoneNoneFalseNoneFalse11370.00
3743947139840NoneItem05Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP long above 6 mtr up to 10 mtr from tapping point to out let via switchEach555.0555.098.0FalseNoneNoneFalseNoneFalse54390.00
3743948139840NoneItem06Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6 amps 3/5 wayEach147.0147.025.0FalseNoneNoneFalseNoneFalse3675.00
3743949139840NoneItem07Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 wayEach319.0319.020.0FalseNoneNoneFalseNoneFalse6380.00
3743950139840NoneItem08Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 wayEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3743951139840NoneItem09Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 wayEach261.0261.06.0FalseNoneNoneFalseNoneFalse1566.00
3743952139840NoneItem10Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 modularEach175.0175.04.0FalseNoneNoneFalseNoneFalse700.00
3743953139840NoneItem11Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 moduleEach284.0284.06.0FalseNoneNoneFalseNoneFalse1704.00
3743954139840NoneItem12Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 moduleEach344.0344.020.0FalseNoneNoneFalseNoneFalse6880.00
3743955139840NoneItem13Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. 4 Way TP & NEach3053.03053.02.0FalseNoneNoneFalseNoneFalse6106.00
3743956139840NoneItem14Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SPEach415.0415.023.0FalseNoneNoneFalseNoneFalse9545.00
3743957139840NoneItem15Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPNEach3044.03044.02.0FalseNoneNoneFalseNoneFalse6088.00
3743958139840NoneItem16Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mmRmtr42.042.0650.0FalseNoneNoneFalseNoneFalse27300.00
3743959139840NoneItem17Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 4. sq mmRmtr63.063.0300.0FalseNoneNoneFalseNoneFalse18900.00
3743960139840NoneItem18Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 6 sq mmRmtr92.092.0200.0FalseNoneNoneFalseNoneFalse18400.00
3743961139840NoneItem19Supplying of box fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube.1 x 4' Tube light fitting.Each340.0340.093.0FalseNoneNoneFalseNoneFalse31620.00
3743962139840NoneItem20Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each122.0122.093.0FalseNoneNoneFalseNoneFalse11346.00
3743963139840NoneItem21Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48 sweep (1200 mm) regular modelEach2984.02984.040.0FalseNoneNoneFalseNoneFalse119360.00
3743964139840NoneItem22Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each171.0171.040.0FalseNoneNoneFalseNoneFalse6840.00
3743965139840NoneItem23Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch 6/16A univarsal socketEach180.0180.04.0FalseNoneNoneFalseNoneFalse720.00
3743966139840NoneItem24Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch 6/16A univarasal SocketEach236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3743967139840NoneItem25Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch 400 watts dimmerEach276.0276.040.0FalseNoneNoneFalseNoneFalse11040.00
3743968139840NoneItem26Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipeto the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipeshall have 16 through holes of 12mm dia.Each3750.03750.01.0FalseNoneNoneFalseNoneFalse3750.00
3743969139840NoneItem27Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 12 sweep (300 mm)Each2969.02969.05.0FalseNoneNoneFalseNoneFalse14845.00
3743970139840NoneItem28Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each492.0492.05.0FalseNoneNoneFalseNoneFalse2460.00
3743971139840NoneItem29PHYSICS LAB ELECTRIFICATION WORK : -Supplying heavy gauge PVC conduit pipe ...2. mm dia.....25...mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickRmtr81.081.0340.0FalseNoneNoneFalseNoneFalse27540.00
3743972139840NoneItem30Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. up to 50 mmRmtr29.029.0200.0FalseNoneNoneFalseNoneFalse5800.00
3743973139840NoneItem31Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP short point up to 3 mtr from tapping point out let via switchEach269.0269.04.0FalseNoneNoneFalseNoneFalse1076.00
3743974139840NoneItem32Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchEach379.0379.06.0FalseNoneNoneFalseNoneFalse2274.00
3743975139840NoneItem33Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP long above 6 mtr up to 10 mtr from tapping point to out let via switchEach555.0555.033.0FalseNoneNoneFalseNoneFalse18315.00
3743976139840NoneItem34Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6 amps 3/5 wayEach170.0170.040.0FalseNoneNoneFalseNoneFalse6800.00
3743977139840NoneItem35Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 wayEach319.0319.012.0FalseNoneNoneFalseNoneFalse3828.00
3743978139840NoneItem36Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 wayEach177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3743979139840NoneItem37Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 wayEach261.0261.042.0FalseNoneNoneFalseNoneFalse10962.00
3743980139840NoneItem38Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 modularEach175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
3743981139840NoneItem39Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 moduleEach284.0284.042.0FalseNoneNoneFalseNoneFalse11928.00
3743982139840NoneItem40Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 moduleEach344.0344.012.0FalseNoneNoneFalseNoneFalse4128.00
3743983139840NoneItem41Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. 4 Way TP & NEach3053.03053.02.0FalseNoneNoneFalseNoneFalse6106.00
3743984139840NoneItem42Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SPEach415.0415.024.0FalseNoneNoneFalseNoneFalse9960.00
3743985139840NoneItem43Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPNEach3044.03044.02.0FalseNoneNoneFalseNoneFalse6088.00
3743986139840NoneItem44Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mmRmtr42.042.0450.0FalseNoneNoneFalseNoneFalse18900.00
3743987139840NoneItem45Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 4. sq mmRmtr63.063.0200.0FalseNoneNoneFalseNoneFalse12600.00
3743988139840NoneItem46Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 6 sq mmRmtr92.092.0150.0FalseNoneNoneFalseNoneFalse13800.00
3743989139840NoneItem47Supplying of box fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube.1 x 4' Tube light fitting.Each340.0340.031.0FalseNoneNoneFalseNoneFalse10540.00
3743990139840NoneItem48Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each122.0122.031.0FalseNoneNoneFalseNoneFalse3782.00
3743991139840NoneItem49Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48 sweep (1200 mm) regular modelEach2984.02984.012.0FalseNoneNoneFalseNoneFalse35808.00
3743992139840NoneItem50Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each171.0171.012.0FalseNoneNoneFalseNoneFalse2052.00
3743993139840NoneItem51Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch 6/16A univarsal socketEach180.0180.01.0FalseNoneNoneFalseNoneFalse180.00
3743994139840NoneItem52Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch 6/16A univarasal SocketEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3743995139840NoneItem53Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16 amps on way switch 400 watts dimmerEach276.0276.012.0FalseNoneNoneFalseNoneFalse3312.00
3743996139840NoneItem54Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipeto the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipeshall have 16 through holes of 12mm dia.Each3750.03750.01.0FalseNoneNoneFalseNoneFalse3750.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17232755240000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17232755240000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17232755240000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17232755240000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17232755240000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17232755830000NoneNoneELIGIBILITYFinancial bids of the technically qualified bidders only will be openedNone
17232755990000NoneNoneELIGIBILITYRight of acceptance or rejection of any or all tenders with or without any reasons is reserved with the undersigned or any concerned higher officers of the DepartmentNone
17232756080000NoneNoneELIGIBILITYConditional tender will not be ConsideredNone
17232756170000NoneNoneELIGIBILITYTender processing amount will not be refundableNone
17232756250000NoneNoneELIGIBILITYContractors should have to upload the scan copy of all necessary qualification documents, and submit the original documents certificates while tender opening evaluation for verificationNone
17232756340000NoneNoneELIGIBILITYThe Photos and Video graphs should be taken before commencement, during execution and after completion of the work in presence of nodal officersNone
17232756430000NoneNoneELIGIBILITYThe liquidated damage for whole of the works are Rs. 0.10 percent per day the maximum amount of liquidated damages for the whole of works is 10 percent of final contract priceNone
17232756520000NoneNoneELIGIBILITYThe agency shall furnish affidavit stating that existing commitments furnished by him are true. If found falls action shall be taken as per lawNone
17232756600000NoneNoneELIGIBILITYThe bidder shall bear all costs associated with the preparation and submission of each tender and the employer will in no case be responsible and liable for those costs. The department is not responsible for any delay in accessing e-procurement portalNone
17232756690000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD 300 LET 2006 Bangalore Dated 01/01/2007 and Government Letter No.PW 134 BMS 2007 Dated 27/7/2007 a sum amounting to 1 percent of the bill amount will be deducted towards Construction Labour Welfare fundNone
17232756780000NoneNoneELIGIBILITYThe Item Rates quoted shall include cost of Royalty charges on construction materials and other taxes as per the prevailing Government Orders at the time of execution and including cost and conveyance of all materials, curing, loading and unloading, with all leads and lifts, labour, hire charges of all machineries and equipments and all incidental charges etc complete necessary for completion of work. All the Items shall be executed as directed by the Engineer-in-charge of the workNone
17232756880000NoneNoneELIGIBILITYThe field laboratory shall preferably locate, adjacent to the site with the required amenity as per the clauseNone
17232756960000NoneNoneELIGIBILITYSelf declaration of machineries are not acceptedNone
17232757040000NoneNoneELIGIBILITYThe work should be completed within the stipulated period from the date of agreement and The date of agreement itself is the date of commencement of the workNone
17232757200000NoneNoneELIGIBILITYThird party inspection is mandatory for all the works in this programmeNone
17232757320000NoneNoneELIGIBILITYThe Tenderer shall obtain the work done certificate in the prescribed form from the competent authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate / Certificates shall be produced whenever requiredNone
17232757410000NoneNoneELIGIBILITYExecutive Engineer has authority to accept or reject any tender without assigning reasonNone
17232757540000NoneNoneELIGIBILITYTenderer must submit his present accurate postal address and phone / cell phone numberNone
17232757670000NoneNoneELIGIBILITYFor interpretations of clauses, conditions, spelling mistakes, etc., decision of Executive Engineer, is finalNone
17232757760000NoneNoneELIGIBILITYThe bidder must submit 5 years Profit and loss account obtained from Chartered Accountant (CA) Only. General Category Bidders must have annual contract turn over for 2 years not less than amount put to tenderNone
17232757850000NoneNoneELIGIBILITYThe Furnished E.M.D. will be released only after successfully execution of the Tender Agreement by the successful Tenderer or bid validity days from the date of submission of Tender whichever is earlierNone
17232757930000NoneNoneELIGIBILITYBefore tendering for the works the tenderer may inspect the site personallyNone
17232758010000NoneNoneELIGIBILITYThe successful tenderer shall maintain the work during the defect liability period of 12 months from the date of completion of the workNone
17232758090000NoneNoneELIGIBILITYThe Tenderer shall have valid KPWD licenseNone
17232758180000NoneNoneELIGIBILITYOther details and instructions shall be seen and fallowed as per the bidding documents KWNone
17232758270000NoneNoneELIGIBILITYThe Road / Building constructed under this programme shall be of high standard, requiring no major repairs for 1 years, The contractor shall furnish performance guarantee for 1 years as per clause and the performance guarantee will be released only after 1 years after completion of workNone
17232758350000NoneNoneELIGIBILITYIf Unnecessary documents uploaded by the bidder then tender will be directly rejected and further correspondence will not be entertained declaration should be uploaded on bidders letter head duly signedNone
17232758440001NoneNoneELIGIBILITYThe work should be completed within 11 months including mansoonNone
17232758520000NoneNoneELIGIBILITYThe Bidder should not quote above amount put to tenderNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNone3.To qualify for award of this contract, Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily completed, as a prime contractor, for at least one similar work of value not less than Rs. 79.69 Lakhs attach certificate by not below rank of Executive Engineer with Indent No. from e-Procurement Portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNone4.To qualify for award of this contract, Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily executed quantities of works in any one year for continues period of 12 months 80 percent of tendered Quantity 1) Earthwork Embankment 707.18 Cum, 2) UCR/BBM 214.41 Cum 3) PCC/ RCC: 270.60 Cum, 4) Plastering 1924.79 Sqm, 5) Flooring 789.02 Sqm 5) Steel 26.55 M.TonnePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNone1.The Tenderer shall have valid class -III KPWD LicenceCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNone7.Name of the Equipment Machineries All machinery Documents are RC Book will be verified from E Vahan website if not found valid then bid will be rejected Tenderer should further demonstrate Owned Machineries This clause is Exempted upto 300 lakh Estimate costCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Machineries
NoneNoneNoneNone2.To qualify for award of this contract, Each tenderer in its name should have in the last five year 2019-20 to 2023-24 Achieved in at least Two financial years an average annual financial turnover not less than in all classes of civil engineering construction works only of Rs. 318.76 Lakhs. Attach certificated from C.A. on Letter Head Two times amount put to tender. with UDIN No. otherwise bid will be directly disqualifiedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNone5.Line of credit Rs. 43.47 Lakhs should be enclosed in prescribed formatFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNone6.Bid Capacity on Letter of the contractorOthers6.Bid Capacity on Letter of the contractor
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- 6.Bid Capacity on Letter of the contractor
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
1.The Tenderer shall have valid class -III KPWD LicenceTrueTechnical Bid
2.To qualify for award of this contract, Each tenderer in its name should have in the last five year 2019-20 to 2023-24 Achieved in at least Two financial years an average annual financial turnover not less than in all classes of civil engineering construction works only of Rs. 318.76 Lakhs. Attach certificated from C.A. on Letter Head Two times amount put to tender. with UDIN No. otherwise bid will be directly disqualifiedTrueTechnical Bid
3.To qualify for award of this contract, Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily completed, as a prime contractor, for at least one similar work of value not less than Rs. 79.69 Lakhs attach certificate by not below rank of Executive Engineer with Indent No. from e-Procurement Portal.TrueTechnical Bid
4.To qualify for award of this contract Each tenderer in his name should have in the last five year from 2019-20 to 2023-24 Satisfactorily executed quantities of works in any one year for continues period of 12 months 80 percent of tendered Quantity 1. Earthwork Embankment 707.18 Cum, 2. UCR BBM 214.41 Cum 3. PCC RCC 270.60 Cum 4. Plastering 1924.79 Sqm, 5. Flooring 789.02 Sqm 6. Steel 26.55 M.TonneTrueTechnical Bid
5.Line of credit Rs. 43.47 Lakhs should be enclosed in prescribed formatTrueTechnical Bid
6.Bid Capacity on Letter of the contractorTrueTechnical Bid
7.Name of the Equipment Machineries All machinery Documents are RC Book will be verified from E Vahan website if not found valid then bid will be rejected Tenderer should further demonstrate Owned Machineries This clause is Exempted upto 300 lakh Estimate costTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1723445952000
version0
createdDateNone
modifiedDateNone
blockNumberExecutive Engineer, P.R.E. Division, Yadgir Opp NVM Hotel, Station Road, Yadgir
streetNone
cityYADGIR
stateKarnataka
pin585202
tenderRecallDTONone