createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723443957278
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1800.00
emd169320.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-08-2024 16:30:00
tenderQueryClose19-08-2024 17:30:00
technicalBidOpen21-08-2024 16:45:00
publishedDate12-08-2024 17:26:29
publishedByPostCMC_MCOM_SDNR
publishedByUserKPE11197 - MANJUNATH MALLAPPA GUNDURU
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonShanthakumar JE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9945947940
tenderSupplierListNone
tenderSchedule
createdTs1723443957308
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT25868
titleConstruction of Proposed 12TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) in SWM Site in Sindhanur Municipal Limit.
descriptionConstruction of Proposed 12TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) in SWM Site in Sindhanur Municipal Limit.
categoryWORKS
categoryTextWorks
ecv7162245.33
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2373
locationNameDMA City Municipal Council Sindhanuru
provisionalAmount8466000.0
groupOverheadTotalNone
fileNumberCMCSND/ENg/SBM2/MRF/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17234439570000NoneNoneBuildingsConstruction of Proposed 12TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) in SWM Site in Sindhanur Municipal Limit.7162245.33
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3753462140881Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.Cum107.1107.174.34FalseNoneNoneFalseNoneFalse7961.8140
3753463140881Nonecode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1,Cum5947.25947.265.62FalseNoneNoneFalseNoneFalse390255.2640
3753464140881Nonecode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 FootingCum7322.47322.495.6FalseNoneNoneFalseNoneFalse700021.440
3753465140881Nonecode04KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 ColumnCum11340.011340.09.21FalseNoneNoneFalseNoneFalse104441.40
3753466140881Nonecode05KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9820.89820.811.43FalseNoneNoneFalseNoneFalse112251.7440
3753467140881Nonecode06KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Kgs93.9393.939116.3FalseNoneNoneFalseNoneFalse856294.0590
3753468140881Nonecode07KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) .Cum6708.456708.4540.65FalseNoneNoneFalseNoneFalse272698.49250
3753469140881Nonecode08KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum474.0474.0323.53FalseNoneNoneFalseNoneFalse153353.220
3753470140881Nonecode09KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1292.551292.55242.64FalseNoneNoneFalseNoneFalse313624.3320
3753471140881Nonecode10KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75533.43FalseNoneNoneFalseNoneFalse165229.94250
3753472140881Nonecode11Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.Kgs118.65118.6518500.0FalseNoneNoneFalseNoneFalse2195025.00
3753473140881Nonecode12Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm585.04585.041623.51FalseNoneNoneFalseNoneFalse949818.29040
3753474140881Nonecode13KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm105.0105.0533.43FalseNoneNoneFalseNoneFalse56010.150
3753475140881Nonecode14KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.No76.6576.65263.43FalseNoneNoneFalseNoneFalse20191.90950
3753476140881Nonecode15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in chargeNo76.6576.65240.59FalseNoneNoneFalseNoneFalse18441.22350
3753477140881Nonecode16KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2764.652764.6533.75FalseNoneNoneFalseNoneFalse93306.93750
3753478140881Nonecode17KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeNo25920.325920.32.0FalseNoneNoneFalseNoneFalse51840.60
3753479140881Nonecode18KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specificationsKgs474.6474.6360.0FalseNoneNoneFalseNoneFalse170856.00
3753480140881Nonecode19Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm145.95145.95871.18FalseNoneNoneFalseNoneFalse127148.7210
3753481140881Nonecode20Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.Each6390.36390.31.0FalseNoneNoneFalseNoneFalse6390.30
3753482140881Nonecode21Three Pole- 100 A 25 kAEach8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3753483140881Nonecode22Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kAEach220.5220.56.0FalseNoneNoneFalseNoneFalse1323.00
3753484140881Nonecode23Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 63 A TPEach1254.751254.758.0FalseNoneNoneFalseNoneFalse10038.00
3753485140881Nonecode24Supplying of 100A 4x30x6mm Aluminium Strips rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.Mtr2588.252588.2520.0FalseNoneNoneFalseNoneFalse51765.00
3753486140881Nonecode25Supplying and fixing angle iron frame work fabricated out of M.S.angle iron..and M.S.Flat 40x40x6mm with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.Mtr320.25320.2510.0FalseNoneNoneFalseNoneFalse3202.50
3753487140881Nonecode26Fabricating supplying and mounting MS box made out 14 SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., completeCum0.530.531000.0FalseNoneNoneFalseNoneFalse530.00
3753488140881Nonecode27Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947Each1354.51354.510.0FalseNoneNoneFalseNoneFalse13545.00
3753489140881Nonecode28Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.Each5085.155085.152.0FalseNoneNoneFalseNoneFalse10170.30
3753490140881Nonecode29Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.Each1396.51396.52.0FalseNoneNoneFalseNoneFalse2793.00
3753491140881Nonecode30Supplying and fixing of metal clad industrial plugs and sockets.Each474.6474.65.0FalseNoneNoneFalseNoneFalse2373.00
3753492140881Nonecode31Supplying and fixing of metal clad industrial plugs and sockets. 16 AmpsEach640.35640.353.0FalseNoneNoneFalseNoneFalse1921.050
3753493140881Nonecode32Supplying,fixing and wiring 0to30 A Direct Reading AC analog type AmmeterEach488.25488.252.0FalseNoneNoneFalseNoneFalse976.50
3753494140881Nonecode33Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood boardEach474.6474.63.0FalseNoneNoneFalseNoneFalse1423.80
3753495140881Nonecode34Supplying,fixing and wiring rotary selector switch suitable for Ammeter.Each210.0210.02.0FalseNoneNoneFalseNoneFalse420.00
3753496140881Nonecode35Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3753497140881Nonecode36Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape WoundEach590.1590.12.0FalseNoneNoneFalseNoneFalse1180.20
3753498140881Nonecode37Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.Each1023.751023.751.0FalseNoneNoneFalseNoneFalse1023.750
3753499140881Nonecode38Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motorKvar504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3753500140881Nonecode391.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975Km187921.65187921.650.1FalseNoneNoneFalseNoneFalse18792.1650
3753501140881Nonecode401.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5Cx50 Sqmm Al Ar cableKm188836.2188836.20.1FalseNoneNoneFalseNoneFalse18883.620
3753502140881Nonecode411.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 4Cx25 Sqmm Al Ar cableKm148934.1148934.10.1FalseNoneNoneFalseNoneFalse14893.410
3753503140881Nonecode421.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 4Cx16 Sqmm Al Ar cableKm123904.2123904.20.1FalseNoneNoneFalseNoneFalse12390.420
3753504140881Nonecode43Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum508.2508.213.5FalseNoneNoneFalseNoneFalse6860.70
3753505140881Nonecode44Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type TerminationsSet199.5199.52.0FalseNoneNoneFalseNoneFalse399.00
3753506140881Nonecode45Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduitMtr72.4572.4550.0FalseNoneNoneFalseNoneFalse3622.50
3753507140881Nonecode46Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 32mm dia PVC 2.5mm thick conduitMtr111.3111.3100.0FalseNoneNoneFalseNoneFalse11130.00
3753508140881Nonecode47Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch.Each299.25299.2510.0FalseNoneNoneFalseNoneFalse2992.50
3753509140881Nonecode48Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switchEach413.7413.710.0FalseNoneNoneFalseNoneFalse4137.00
3753510140881Nonecode49Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.Each598.5598.55.0FalseNoneNoneFalseNoneFalse2992.50
3753511140881Nonecode50Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switchesEach743.0743.05.0FalseNoneNoneFalseNoneFalse3715.00
3753512140881Nonecode51Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switchesEach1086.751086.755.0FalseNoneNoneFalseNoneFalse5433.750
3753513140881Nonecode52Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.1.0 Sqmm Cu FRLS wire.Mtr19.9519.95100.0FalseNoneNoneFalseNoneFalse1995.00
3753514140881Nonecode53Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.1.5 Sqmm Cu FRLS wire.Mtr27.327.3200.0FalseNoneNoneFalseNoneFalse5460.00
3753515140881Nonecode54Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.2.5 Sqmm Cu FRLS wire.Mtr44.144.1300.0FalseNoneNoneFalseNoneFalse13230.00
3753516140881Nonecode55Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.4.0 Sqmm Cu FRLS wireMtr66.1566.15200.0FalseNoneNoneFalseNoneFalse13230.00
3753517140881Nonecode56Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.6.0 Sqmm Cu FRLS wireMtr96.696.6100.0FalseNoneNoneFalseNoneFalse9660.00
3753518140881Nonecode57Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate.Each361.2361.25.0FalseNoneNoneFalseNoneFalse1806.00
3753519140881Nonecode58Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 3 Module Polycarbonate switch box plate.Each169.05169.0510.0FalseNoneNoneFalseNoneFalse1690.50
3753520140881Nonecode59Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 WayEach130.2130.210.0FalseNoneNoneFalseNoneFalse1302.00
3753521140881Nonecode60Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 10-12 WayEach274.05274.0510.0FalseNoneNoneFalseNoneFalse2740.50
3753522140881Nonecode61Supply & fixing of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000hr Lumen Maintenance of 70%, CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. PowerFactor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage /Overload, short circuit/ miss-wiring protection.Compatible for pole mauling with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60 Hz application.Compliance to IS 10322/IEC60598 ,LM79 & LM80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with.......W System Power consumption.LED Efficiency1301m/w, nominal CRI75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier wordmark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working understand ard electrical conditions as mentioned above should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source. LED flood light 100WEach9960.39960.310.0FalseNoneNoneFalseNoneFalse99603.00
3753523140881Nonecode62Earthing GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI StripMtr86.186.150.0FalseNoneNoneFalseNoneFalse4305.00
3753524140881Nonecode632 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as requiredMtr616.35616.3520.0FalseNoneNoneFalseNoneFalse12327.00
3753525140881Nonecode64Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each3685.53685.53.0FalseNoneNoneFalseNoneFalse11056.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17234439580000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17234439580000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17234439580001NoneNoneELIGIBILITYAll Terms and Conidiations as per bid DocumentNone
17234439580000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17234439580000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. 42.33 (50% of estimated cost of tender)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete -145.49 cum, TMT Stee 7293.04 Kgs, Structural Steel work 14800.00 Kgs and Galvanised iron profile sheets 1298.81 Sqm, etc) (80% of peak rate of construction)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. 2.01 (not less than 50% of electrical works) n any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonePWD Contractor Registration CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Qualification and experience
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 169.32Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 25.40 Lakhs (estimated cash flow for 3 months of peak construction period)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneBanker Details for referenceOthersBanker Details for reference
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneGST Registration CertificateOthersGST Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Contractor Registration CertificateTrueTechnical Bid
Annual Turnover CertificateTrueTechnical Bid
Liquid assets for Bankers CertificateTrueTechnical Bid
Similar nature of work done certificateTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
Work Done Certificates QTY WiseTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsRaichuruSindhanuruRaichurSINDHNOORSWM Site SindhanurNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone