tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1723555499000 | 1 | None | None | Buildings | Civil Work for Bus Stand | 815955.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3772107 | 142106 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the elected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. (PWD SR 2023-24 VOL-1 P NO-05 I NO- 1.4.1) | Cum | 254.1 | 254.1 | 7.938 | False | None | None | False | None | False | 2017.0458 | 0 | 3772108 | 142106 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates PWD Common SR 2023-24 VOl.1(Page No.15, I.No.2.1.2) | Cum | 5947.2 | 5947.2 | 1.422 | False | None | None | False | None | False | 8456.9184 | 0 | 3772109 | 142106 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates PWD SR Vol 1 P No 151 I No 2.1.6 | Cum | 6555.15 | 6555.15 | 4.794 | False | None | None | False | None | False | 31425.3891 | 0 | 3772110 | 142106 | None | code04 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For RCC Columns / Shaft (Slip Centering) Form Works Consider 70percent PWD Common SR 2023-24 Volume 1 (P No: 111 I.No:9) | Cum | 4588.6 | 4588.6 | 1.62 | False | None | None | False | None | False | 7433.532 | 0 | 3772111 | 142106 | None | code05 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For RCC beamTroughs of Aqueducts Form Works Consider 50percent PWD Common SR 2023-24 Volume 1 (P No: 111 I.No:14) | Cum | 3277.57 | 3277.57 | 2.76 | False | None | None | False | None | False | 9046.0932 | 0 | 3772112 | 142106 | None | code06 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. PWD Common SR 2023-24 Volume 1 (P No: 18 I.No:2.11h ) | Tonne | 82961.55 | 82961.55 | 0.4794 | False | None | None | False | None | False | 39771.76707 | 0 | 3772113 | 142106 | None | code07 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD Common SR 2023-24 Volume 2 (P No:41 I.No: 8.4.1) | Sqm | 339.15 | 339.15 | 39.0 | False | None | None | False | None | False | 13226.85 | 0 | 3772114 | 142106 | None | code08 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD Common DSR 2023-24 Volume 1 (P No:7 I.No:1.9) | Cum | 279.3 | 279.3 | 18.0 | False | None | None | False | None | False | 5027.4 | 0 | 3772115 | 142106 | None | code09 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.DSR 2023-24 Volume 2 (P No:63 I.No:9.24) | Sqm | 2994.6 | 2994.6 | 31.5 | False | None | None | False | None | False | 94329.9 | 0 | 3772116 | 142106 | None | code10 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usagecharges of machinery complete as per specifications and as per directions of the Engineer-in-Charge PWD Common SR 2023-24 Volume 2 (P No: 82 I.No:11.16.1) | Kg | 142.8 | 142.8 | 1299.3695 | False | None | None | False | None | False | 185549.9646 | 0 | 3772117 | 142106 | None | code11 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resist ance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sand wiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., completeFor Curved Portion PWD Common SR 2023-24 Volume 2 (P No: 71 I.No:10.15.2) | Sqm | 4981.2 | 4981.2 | 69.5 | False | None | None | False | None | False | 346193.4 | 0 | 3772118 | 142106 | None | code12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 percent) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required PWD Common DSR 2023-24 Volume3 (Page No 26 I.No7.38) | Sqm | 596.4 | 596.4 | 48.0 | False | None | None | False | None | False | 28627.2 | 0 | 3772119 | 142106 | None | code13 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.DSR 2023-24 Volume3 (Page No 85 I.No11.85) | Kg | 593.25 | 593.25 | 75.6 | False | None | None | False | None | False | 44849.7 | 0 |
| 1723555499000 | 1 | None | None | Buildings | Bus Stand Electrical Work | 30596.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3772120 | 142107 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .25mm. etc. as required. | Mtr | 35.0 | 35.0 | 20.0 | False | None | None | False | None | False | 700.0 | 0 | 3772121 | 142107 | None | code02 | I.Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5msqm (Phase & Neutral) & 1x1.0 msqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 8.0 | False | None | None | False | None | False | 3152.0 | 0 | 3772122 | 142107 | None | code03 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments1.5 sqmm | Mtr | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | 3772123 | 142107 | None | code04 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmm | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | 3772124 | 142107 | None | code05 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 138.0 | 138.0 | 4.0 | False | None | None | False | None | False | 552.0 | 0 | 3772125 | 142107 | None | code06 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 1 to 3 Module | Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 | 3772126 | 142107 | None | code07 | Supplying of ..feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI greter 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fitting 1 x 4'- 20/22 w Each LED light fitting 1 x 4'- 20/22 w Each | Each | 690.0 | 690.0 | 10.0 | False | None | None | False | None | False | 6900.0 | 0 | 3772127 | 142107 | None | code08 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.a) 6-32Amps SP Group 'A' | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 3772128 | 142107 | None | code09 | Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | m | 2500.0 | 2500.0 | 6.0 | False | None | None | False | None | False | 15000.0 | 0 |
| 1723555625000 | 0 | None | None | Buildings | Construction of Bus stop near Kogale Hotel of Ward no 18 at Sadalga Town | 846551.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3772422 | 142121 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .25mm. etc. as required. | Mtr | 35.0 | 35.0 | 20.0 | False | None | None | False | None | False | 700.0 | 0 | 3772409 | 142121 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the elected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. (PWD SR 2023-24 VOL-1 P NO-05 I NO- 1.4.1) | Cum | 254.1 | 254.1 | 7.938 | False | None | None | False | None | False | 2017.0458 | 0 | 3772410 | 142121 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates PWD Common SR 2023-24 VOl.1(Page No.15, I.No.2.1.2) | Cum | 5947.2 | 5947.2 | 1.422 | False | None | None | False | None | False | 8456.9184 | 0 | 3772423 | 142121 | None | code02 | I.Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5msqm (Phase & Neutral) & 1x1.0 msqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 8.0 | False | None | None | False | None | False | 3152.0 | 0 | 3772411 | 142121 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates PWD SR Vol 1 P No 151 I No 2.1.6 | Cum | 6555.15 | 6555.15 | 4.794 | False | None | None | False | None | False | 31425.3891 | 0 | 3772424 | 142121 | None | code03 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments1.5 sqmm | Mtr | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | 3772412 | 142121 | None | code04 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For RCC Columns / Shaft (Slip Centering) Form Works Consider 70percent PWD Common SR 2023-24 Volume 1 (P No: 111 I.No:9) | Cum | 4588.6 | 4588.6 | 1.62 | False | None | None | False | None | False | 7433.532 | 0 | 3772425 | 142121 | None | code04 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmm | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | 3772413 | 142121 | None | code05 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For RCC beamTroughs of Aqueducts Form Works Consider 50percent PWD Common SR 2023-24 Volume 1 (P No: 111 I.No:14) | Cum | 3277.57 | 3277.57 | 2.76 | False | None | None | False | None | False | 9046.0932 | 0 | 3772426 | 142121 | None | code05 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 138.0 | 138.0 | 4.0 | False | None | None | False | None | False | 552.0 | 0 | 3772427 | 142121 | None | code06 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 1 to 3 Module | Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 | 3772414 | 142121 | None | code06 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. PWD Common SR 2023-24 Volume 1 (P No: 18 I.No:2.11h ) | Tonne | 82961.55 | 82961.55 | 0.4794 | False | None | None | False | None | False | 39771.76707 | 0 | 3772415 | 142121 | None | code07 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD Common SR 2023-24 Volume 2 (P No:41 I.No: 8.4.1) | Sqm | 339.15 | 339.15 | 39.0 | False | None | None | False | None | False | 13226.85 | 0 | 3772428 | 142121 | None | code07 | Supplying of ..feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI greter 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fitting 1 x 4'- 20/22 w Each LED light fitting 1 x 4'- 20/22 w Each | Each | 690.0 | 690.0 | 10.0 | False | None | None | False | None | False | 6900.0 | 0 | 3772416 | 142121 | None | code08 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD Common DSR 2023-24 Volume 1 (P No:7 I.No:1.9) | Cum | 279.3 | 279.3 | 18.0 | False | None | None | False | None | False | 5027.4 | 0 | 3772429 | 142121 | None | code08 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.a) 6-32Amps SP Group 'A' | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 3772417 | 142121 | None | code09 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.DSR 2023-24 Volume 2 (P No:63 I.No:9.24) | Sqm | 2994.6 | 2994.6 | 31.5 | False | None | None | False | None | False | 94329.9 | 0 | 3772430 | 142121 | None | code09 | Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | m | 2500.0 | 2500.0 | 6.0 | False | None | None | False | None | False | 15000.0 | 0 | 3772418 | 142121 | None | code10 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usagecharges of machinery complete as per specifications and as per directions of the Engineer-in-Charge PWD Common SR 2023-24 Volume 2 (P No: 82 I.No:11.16.1) | Kg | 142.8 | 142.8 | 1299.3695 | False | None | None | False | None | False | 185549.9646 | 0 | 3772419 | 142121 | None | code11 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resist ance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sand wiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., completeFor Curved Portion PWD Common SR 2023-24 Volume 2 (P No: 71 I.No:10.15.2) | Sqm | 4981.2 | 4981.2 | 69.5 | False | None | None | False | None | False | 346193.4 | 0 | 3772420 | 142121 | None | code12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 percent) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required PWD Common DSR 2023-24 Volume3 (Page No 26 I.No7.38) | Sqm | 596.4 | 596.4 | 48.0 | False | None | None | False | None | False | 28627.2 | 0 | 3772421 | 142121 | None | code13 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.DSR 2023-24 Volume3 (Page No 85 I.No11.85) | Kg | 593.25 | 593.25 | 75.6 | False | None | None | False | None | False | 44849.7 | 0 |
|
|
---|