3755157 | 141019 | None | code01 | Dismantling of bilichodu section office duly dismantling old building including buyback items and clearing the site complete as per specification and direction of Engineer in charge of the work including buy back items as per attached sub estimate | No | 1023.93 | 1023.93 | 1.0 | False | None | None | False | None | False | 1023.93 | 0 |
3755158 | 141019 | None | code02 | Providing block level and contour survey of the land proposed for construction, Soil investigation of the proposed for construction, preparation and submission Structural, Design details , Electrical layout, plumbing & sanitary system and all other detailed drawing required for successful completion of the project | Job | 88500.0 | 88500.0 | 1.0 | False | None | None | False | None | False | 88500.0 | 0 |
3755159 | 141019 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soil Depth upto 3 m | Cum | 120.36 | 120.36 | 280.0 | False | None | None | False | None | False | 33700.8 | 0 |
3755160 | 141019 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 313.88 | 313.88 | 280.0 | False | None | None | False | None | False | 87886.4 | 0 |
3755161 | 141019 | None | code05 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labor, rolling, water, all materials, usage & all other appurtenances required to complete the work. Deduct 5% cubic meter if rollers are not used and tamping is done manually | Cum | 559.32 | 559.32 | 380.0 | False | None | None | False | None | False | 212541.6 | 0 |
3755162 | 141019 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6683.52 | 6683.52 | 55.0 | False | None | None | False | None | False | 367593.6 | 0 |
3755163 | 141019 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7366.74 | 7366.74 | 35.0 | False | None | None | False | None | False | 257835.9 | 0 |
3755164 | 141019 | None | code08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Appendix I - Additionalities for Formwork , centering & Scaffolding for Footing | Cum | 8012.15 | 8012.15 | 35.0 | False | None | None | False | None | False | 280425.25 | 0 |
3755165 | 141019 | None | code09 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevantIS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse, Aggregates & Shuttering columns Appendix 1 at 70 % of finished rate of Concrete Gr Floor | Cum | 13299.78 | 13299.78 | 31.0 | False | None | None | False | None | False | 412293.18 | 0 |
3755166 | 141019 | None | code10 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevantIS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse, Aggregates & Shuttering columns Appendix 1 at 70 % of finished rate of Concrete & Appendix 1- Additionalities for Formwork, Centering & scaffolding For Beam & Lintel centring chages 60 % | Cum | 12517.44 | 12517.44 | 45.0 | False | None | None | False | None | False | 563284.8 | 0 |
3755167 | 141019 | None | code11 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevantIS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse, Aggregates & Shuttering columns Appendix 1 @ 70 % of finished rate of Concrete Appendix 1- Additionalities for Formwork, Centering & scaffolding For Roof centring chages 50 % | Cum | 11735.1 | 11735.1 | 35.0 | False | None | None | False | None | False | 410728.5 | 0 |
3755168 | 141019 | None | code12 | do- Chejja Appendix 1- Additionalities for Formwork, Centering & scaffolding For Chajja centring chages 45 % | Cum | 11343.93 | 11343.93 | 4.0 | False | None | None | False | None | False | 45375.72 | 0 |
3755169 | 141019 | None | code13 | do- Chejja Appendix 1- Additionalities for Formwork, Centering & scaffolding For Roof centring chages 50 % | Cum | 11457.37 | 11457.37 | 3.0 | False | None | None | False | None | False | 34372.11 | 0 |
3755170 | 141019 | None | code14 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | t | 105559.26 | 105559.26 | 15.0 | False | None | None | False | None | False | 1583388.9 | 0 |
3755171 | 141019 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in allshapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)including cost of all materials, labour, scaffolding and usage charges ofmachinery & other incidental charges complete as per the direction ofengineer incharge of work. | Cum | 9403.42 | 9403.42 | 99.0 | False | None | None | False | None | False | 930938.58 | 0 |
3755172 | 141019 | None | code16 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work. | Sqm | 1218.94 | 1218.94 | 30.0 | False | None | None | False | None | False | 36568.2 | 0 |
3755173 | 141019 | None | code17 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as per specifications. | Cum | 162927.32 | 162927.32 | 0.9 | False | None | None | False | None | False | 146634.588 | 0 |
3755174 | 141019 | None | code18 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick one side teak and one side commercial | Sqm | 4121.74 | 4121.74 | 18.0 | False | None | None | False | None | False | 74191.32 | 0 |
3755175 | 141019 | None | code19 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 7759.68 | 7759.68 | 8.0 | False | None | None | False | None | False | 62077.44 | 0 |
3755176 | 141019 | None | code20 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. all floors | Kgs | 577.02 | 577.02 | 300.0 | False | None | None | False | None | False | 173106.0 | 0 |
3755177 | 141019 | None | code21 | Providing and fixing aluminium work for doors, indows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprenegasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. all floors | Kgs | 630.12 | 630.12 | 245.0 | False | None | None | False | None | False | 154379.4 | 0 |
3755178 | 141019 | None | code22 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. all floors | Sqm | 1381.78 | 1381.78 | 60.0 | False | None | None | False | None | False | 82906.8 | 0 |
3755179 | 141019 | None | code23 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge all floors | Mtr | 73.16 | 73.16 | 120.0 | False | None | None | False | None | False | 8779.2 | 0 |
3755180 | 141019 | None | code24 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge all floors | Nos | 84.96 | 84.96 | 60.0 | False | None | None | False | None | False | 5097.6 | 0 |
3755181 | 141019 | None | code25 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal guage) on terraced roof or sunken slabs, laid to slope compacting , including cost of materials, labour, curing, complete as per specifications. all floors | Cum | 2380.06 | 2380.06 | 8.0 | False | None | None | False | None | False | 19040.48 | 0 |
3755182 | 141019 | None | code26 | Providing and laying Polished Glazed Vitrified tiles in wall floor and wall with different sizes thickness to be specified by the manufacture ), with water absorption less than .08% and conforming to IS 15622, of approved brand & manufacture, in all colours and shade, laid with cement based high polymer modified quick set tiles adhesive ( water based ) conforming to IS 15477, in average 6mm thickness , including grouting of joints . Ground floor size of tile 600x600 | Sqm | 1564.68 | 1564.68 | 125.0 | False | None | None | False | None | False | 195585.0 | 0 |
3755183 | 141019 | None | code27 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufactu rer), of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 1049.02 | 1049.02 | 20.0 | False | None | None | False | None | False | 20980.4 | 0 |
3755184 | 141019 | None | code28 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1386.5 | 1386.5 | 25.0 | False | None | None | False | None | False | 34662.5 | 0 |
3755185 | 141019 | None | code29 | Providing and laying flooring and steps fine dressed granite stone slabs 20 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Gr Floor | Sqm | 6287.04 | 6287.04 | 30.0 | False | None | None | False | None | False | 188611.2 | 0 |
3755186 | 141019 | None | code30 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Gr floor | Sqm | 5049.22 | 5049.22 | 40.0 | False | None | None | False | None | False | 201968.8 | 0 |
3755187 | 141019 | None | code31 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Inside plastering | Sqm | 348.1 | 348.1 | 120.0 | False | None | None | False | None | False | 41772.0 | 0 |
3755188 | 141019 | None | code32 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Gr floor | Sqm | 392.94 | 392.94 | 180.0 | False | None | None | False | None | False | 70729.2 | 0 |
3755189 | 141019 | None | code33 | do- outside plastering , Building , Flagging , Sump tank | Sqm | 392.94 | 392.94 | 150.0 | False | None | None | False | None | False | 58941.0 | 0 |
3755190 | 141019 | None | code34 | Providing 12 mm cement plaster with Cement mortar 1:4 (1 cement: 4 fine sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal ceiling | Sqm | 368.16 | 368.16 | 120.0 | False | None | None | False | None | False | 44179.2 | 0 |
3755191 | 141019 | None | code35 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer incharge | Sqm | 118.0 | 118.0 | 200.0 | False | None | None | False | None | False | 23600.0 | 0 |
3755192 | 141019 | None | code36 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charges | Sqm | 149.86 | 149.86 | 500.0 | False | None | None | False | None | False | 74930.0 | 0 |
3755193 | 141019 | None | code37 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 ltr/10 sqm over and including one coat of Special primer applied at 0.75 ltr /10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Out side | Sqm | 186.44 | 186.44 | 500.0 | False | None | None | False | None | False | 93220.0 | 0 |
3755194 | 141019 | None | code38 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) including preparing the surface after throughly cleaing oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per direction of Engineer -in- charge | Sqm | 62.54 | 62.54 | 40.0 | False | None | None | False | None | False | 2501.6 | 0 |
3755195 | 141019 | None | code39 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charges | Sqm | 135.7 | 135.7 | 40.0 | False | None | None | False | None | False | 5428.0 | 0 |
3755196 | 141019 | None | code40 | Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel work including preparing the surface after throughly cleaing oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per direction of Engineer -in- charge | Sqm | 59.0 | 59.0 | 50.0 | False | None | None | False | None | False | 2950.0 | 0 |
3755197 | 141019 | None | code41 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 197.06 | 197.06 | 50.0 | False | None | None | False | None | False | 9853.0 | 0 |
3755198 | 141019 | None | code42 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation. | No | 6657.56 | 6657.56 | 6.0 | False | None | None | False | None | False | 39945.36 | 0 |
3755199 | 141019 | None | code43 | Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan | Each | 2692.76 | 2692.76 | 2.0 | False | None | None | False | None | False | 5385.52 | 0 |
3755200 | 141019 | None | code44 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap all floors | Unit | 3021.98 | 3021.98 | 2.0 | False | None | None | False | None | False | 6043.96 | 0 |
3755201 | 141019 | None | code45 | Providing and fixing brass bib cock of approved quality | Each | 337.48 | 337.48 | 8.0 | False | None | None | False | None | False | 2699.84 | 0 |
3755202 | 141019 | None | code46 | White glazed fire clay kitchen sink of size 600x450x 250 mm | No | 3517.58 | 3517.58 | 2.0 | False | None | None | False | None | False | 7035.16 | 0 |
3755203 | 141019 | None | code47 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. | No | 10.62 | 10.62 | 2000.0 | False | None | None | False | None | False | 21240.0 | 0 |
3755204 | 141019 | None | code48 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixingthe railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steelmembers shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) includingcost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. all Floor | Kgs | 666.7 | 666.7 | 100.0 | False | None | None | False | None | False | 66670.0 | 0 |
3755205 | 141019 | None | code49 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 151.04 | 151.04 | 535.0 | False | None | None | False | None | False | 80806.4 | 0 |
3755206 | 141019 | None | code50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work ( External works) 20 mm dia | Mtr | 256.06 | 256.06 | 35.0 | False | None | None | False | None | False | 8962.1 | 0 |
3755207 | 141019 | None | code51 | do-25 mm dia | Mtr | 349.28 | 349.28 | 50.0 | False | None | None | False | None | False | 17464.0 | 0 |
3755208 | 141019 | None | code52 | do-32 mm dia | Mtr | 438.96 | 438.96 | 50.0 | False | None | None | False | None | False | 21948.0 | 0 |
3755209 | 141019 | None | code53 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.75 mm dia | Mtr | 341.02 | 341.02 | 100.0 | False | None | None | False | None | False | 34102.0 | 0 |
3755210 | 141019 | None | code54 | do- 110 mm dia | Mtr | 454.3 | 454.3 | 50.0 | False | None | None | False | None | False | 22715.0 | 0 |
3755211 | 141019 | None | code55 | do- 150 mm dia | Mtr | 906.24 | 906.24 | 50.0 | False | None | None | False | None | False | 45312.0 | 0 |
3755212 | 141019 | None | code56 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.. 1 HP/ 12 stage | No | 17287.0 | 17287.0 | 1.0 | False | None | None | False | None | False | 17287.0 | 0 |
3755213 | 141019 | None | code57 | Providing and laying reinforced cement concrete pipe of 1.20m dia,0.30 m height for soak pit with including cost of all materials, labour, curing complete as per specifications | No | 849.6 | 849.6 | 20.0 | False | None | None | False | None | False | 16992.0 | 0 |
3755214 | 141019 | None | code58 | Providing and laying flooring with RCC slabs 10cms thick, and pointed with cement mortar 1:3, including cost of materials, labour, curing complete as per specifications. | No | 802.4 | 802.4 | 1.0 | False | None | None | False | None | False | 802.4 | 0 |
3755215 | 141019 | None | code59 | Providing and laying reinforced cement concrete pipe of 0.60 m dia,0.30 m height for soak pit with including cost of all materials, labour, curing complete as per specifications | No | 489.7 | 489.7 | 1.0 | False | None | None | False | None | False | 489.7 | 0 |
3755216 | 141019 | None | code60 | Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary | Mtr | 92.04 | 92.04 | 800.0 | False | None | None | False | None | False | 73632.0 | 0 |
3755217 | 141019 | None | code61 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. | Mtr | 34.22 | 34.22 | 350.0 | False | None | None | False | None | False | 11977.0 | 0 |
3755218 | 141019 | None | code62 | Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch | Point | 336.3 | 336.3 | 40.0 | False | None | None | False | None | False | 13452.0 | 0 |
3755219 | 141019 | None | code63 | do- Medium point above 3 mtrs up to 6 mtrs from tapping point to out let via switch | Point | 464.92 | 464.92 | 25.0 | False | None | None | False | None | False | 11623.0 | 0 |
3755220 | 141019 | None | code64 | do- Long point above 6M upto 10mtr from tapping point to out let via switch | Point | 672.6 | 672.6 | 20.0 | False | None | None | False | None | False | 13452.0 | 0 |
3755221 | 141019 | None | code65 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 1 Sqmm | Mtr | 22.42 | 22.42 | 500.0 | False | None | None | False | None | False | 11210.0 | 0 |
3755222 | 141019 | None | code66 | do- 1.5 Sqmm | Mtr | 30.68 | 30.68 | 450.0 | False | None | None | False | None | False | 13806.0 | 0 |
3755223 | 141019 | None | code67 | do- 2.5 Sqmm | Mtr | 49.56 | 49.56 | 500.0 | False | None | None | False | None | False | 24780.0 | 0 |
3755224 | 141019 | None | code68 | do- 4 Sqmm | Mtr | 74.34 | 74.34 | 300.0 | False | None | None | False | None | False | 22302.0 | 0 |
3755225 | 141019 | None | code69 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps Three way scoket. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 |
3755226 | 141019 | None | code70 | do- 600 watts Dimmer | Each | 388.22 | 388.22 | 8.0 | False | None | None | False | None | False | 3105.76 | 0 |
3755227 | 141019 | None | code71 | do- 6Amps Two way switch | Each | 195.88 | 195.88 | 22.0 | False | None | None | False | None | False | 4309.36 | 0 |
3755228 | 141019 | None | code72 | do- 32 Amps DP | Each | 384.68 | 384.68 | 15.0 | False | None | None | False | None | False | 5770.2 | 0 |
3755229 | 141019 | None | code73 | do- 6/ 16 Amps universal socket | Each | 278.48 | 278.48 | 20.0 | False | None | None | False | None | False | 5569.6 | 0 |
3755230 | 141019 | None | code74 | Supplying and fixing of 70/150 watts lamp holder 2 pin | Each | 74.34 | 74.34 | 50.0 | False | None | None | False | None | False | 3717.0 | 0 |
3755231 | 141019 | None | code75 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flaxible copper conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100 Volts. 3 Core x 2.5 Sqmm | Mtr | 198.24 | 198.24 | 100.0 | False | None | None | False | None | False | 19824.0 | 0 |
3755232 | 141019 | None | code76 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system..48" Sweep (1200 mm) Regular model | Each | 3521.12 | 3521.12 | 5.0 | False | None | None | False | None | False | 17605.6 | 0 |
3755233 | 141019 | None | code77 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 5.0 | False | None | None | False | None | False | 1008.9 | 0 |
3755234 | 141019 | None | code78 | Supplying of box fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube.1 x 4' Tube light fitting | Each | 401.2 | 401.2 | 12.0 | False | None | None | False | None | False | 4814.4 | 0 |
3755235 | 141019 | None | code79 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 |
3755236 | 141019 | None | code80 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and(Virgin)PVCinsulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 10C x 1.5 sqmm | Mtr | 230.1 | 230.1 | 50.0 | False | None | None | False | None | False | 11505.0 | 0 |
3755237 | 141019 | None | code81 | Supplying and drawing PVC Insulated gas injected physical foam jelly flooded co-oxial TV cable RG-6 | Mtr | 51.92 | 51.92 | 50.0 | False | None | None | False | None | False | 2596.0 | 0 |
3755238 | 141019 | None | code82 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and c Type curve indicater ON/OF, energy cros-3 with short circuit breaking capacity of 10k and complete wiring as required confiming to IEC 60898 6-32 A Dp | Each | 872.02 | 872.02 | 12.0 | False | None | None | False | None | False | 10464.24 | 0 |
3755239 | 141019 | None | code83 | Supplying and fixing /replacing of 6/16/32Amps electrical accessories on existing switch board 6Amps 3 pin Top | Each | 102.66 | 102.66 | 4.0 | False | None | None | False | None | False | 410.64 | 0 |
3755240 | 141019 | None | code84 | Supplying and fixing single phase metering panels board , on wall/wood board/ flush mounting using required clamps , bolts, nuts with provision for suitable type capacity MCB's single phase/3 phase / four door with powder coated painting etc | Each | 19883.0 | 19883.0 | 1.0 | False | None | None | False | None | False | 19883.0 | 0 |
3755241 | 141019 | None | code85 | Supplying and fixing regular MCB distribution boards on wall/wood board/ flush mounting using required clamps , bolts, nuts with provision for suitable type capacity MCB's single phase/3 phase / single door with powder coated painting 12 way SP & N | Each | 2198.34 | 2198.34 | 1.0 | False | None | None | False | None | False | 2198.34 | 0 |
3755242 | 141019 | None | code86 | Supplying and fixing of porcelain fuse channels with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 Amps | Each | 284.38 | 284.38 | 1.0 | False | None | None | False | None | False | 284.38 | 0 |
3755243 | 141019 | None | code87 | Supplying of1 x 4' feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 26.0 | False | None | None | False | None | False | 21169.2 | 0 |
3755244 | 141019 | None | code88 | Supplying, fixing, wiring ,earthelectrode forgrounding conduits, I.C.cutout sand othere quipment' sonthemeter board using 40mm dia 2.90mm thick GIpipe2.5mlong buriedinapit. The pit should befilled withequal proportionof saltand charcoal 150mmall-round the pipe to complete depth.Thec onnection from the pipe to the conduitetc .,is to be established through GI wire of size as per lSIspecification 7.3.3.of IS732 using12 mm dia bolts, nuts, washer sand check nut setc., the pipe shall have 16 through holes of 12 mm dia | Each | 4141.8 | 4141.8 | 1.0 | False | None | None | False | None | False | 4141.8 | 0 |
3755245 | 141019 | None | code89 | Supplying and fixing flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates , The box should be firmly flush mounted after due groove cutting in Brick/stone/C.C.wall 3 way | No | 187.62 | 187.62 | 4.0 | False | None | None | False | None | False | 750.48 | 0 |
3755246 | 141019 | None | code90 | do- 4 -5 way | No | 208.86 | 208.86 | 30.0 | False | None | None | False | None | False | 6265.8 | 0 |
3755247 | 141019 | None | code91 | do- 6 way | No | 259.6 | 259.6 | 8.0 | False | None | None | False | None | False | 2076.8 | 0 |
3755248 | 141019 | None | code92 | do- 8 way | No | 307.98 | 307.98 | 10.0 | False | None | None | False | None | False | 3079.8 | 0 |
3755249 | 141019 | None | code93 | do-10 to 12 way | No | 376.42 | 376.42 | 4.0 | False | None | None | False | None | False | 1505.68 | 0 |
3755250 | 141019 | None | code94 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws , bolt nuts etc. | No | 161.66 | 161.66 | 8.0 | False | None | None | False | None | False | 1293.28 | 0 |
3755251 | 141019 | None | code95 | do- 3 Moduler | No | 189.98 | 189.98 | 45.0 | False | None | None | False | None | False | 8549.1 | 0 |
3755252 | 141019 | None | code96 | do- 4 Moduler | No | 206.5 | 206.5 | 8.0 | False | None | None | False | None | False | 1652.0 | 0 |
3755253 | 141019 | None | code97 | do- 6 Moduler | No | 276.12 | 276.12 | 10.0 | False | None | None | False | None | False | 2761.2 | 0 |
3755254 | 141019 | None | code98 | do- 8 Moduler | No | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 |
3755255 | 141019 | None | code99 | do- 10 -12 Moduler | No | 405.92 | 405.92 | 4.0 | False | None | None | False | None | False | 1623.68 | 0 |
3755256 | 141019 | None | code100 | Electrification Charges for service connection , 2 mmd 3KW | No | 1534.0 | 1534.0 | 1.0 | False | None | None | False | None | False | 1534.0 | 0 |
3755257 | 141019 | None | code101 | do- Registration fee | No | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 |
3755258 | 141019 | None | code102 | do- Meter cost | No | 1180.0 | 1180.0 | 1.0 | False | None | None | False | None | False | 1180.0 | 0 |
3755259 | 141019 | None | code103 | do- Agreement fee | No | 354.0 | 354.0 | 1.0 | False | None | None | False | None | False | 354.0 | 0 |
3755260 | 141019 | None | code104 | do- Contractor fee | No | 2360.0 | 2360.0 | 1.0 | False | None | None | False | None | False | 2360.0 | 0 |