createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723449526551
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1990.00
emd79400.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-08-2024 17:00:00
tenderQueryClose27-08-2024 17:00:00
technicalBidOpen30-08-2024 11:00:00
publishedDate13-08-2024 16:24:54
publishedByPostBESCOM_CE_CTAZ_CTD
publishedByUserKPE19796 - M ROMARAJU
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER CIVIL
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08194230088
mobileNumber9448094835
tenderSupplierListNone
tenderSchedule
createdTs1723449526583
version4
createdDateNone
modifiedDateNone
tenderNumberBESCOM/2024-25/BD/WORK_INDENT179
titleConstruction of building to accommodate Bilichodu Section office duly dismantling old building at BESCOM colony premises, Bilichodu (Jagalur Tq.)
descriptionConstruction of building to accommodate Bilichodu Section office duly dismantling old building at BESCOM colony premises, Bilichodu (Jagalur Tq.)
categoryWORKS
categoryTextWorks
ecv7940000.00
deptNameBangalore Electricity Supply Company Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3788
locationNameBESCOM Chitradurga Area Zone(CTAZ) Office Bengaluru
provisionalAmount7940000.0
groupOverheadTotal880.04
fileNumberCEE/CZ/EEC/20-21/LOT1/KW3-1/CALL-2
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17234495270000NoneNoneBuildingsConstruction of building to accommodate Bilichodu Section office duly dismantling old building at BESCOM colony premises, Bilichodu (Jagalur Tq.)7939119.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3755157141019Nonecode01Dismantling of bilichodu section office duly dismantling old building including buyback items and clearing the site complete as per specification and direction of Engineer in charge of the work including buy back items as per attached sub estimateNo1023.931023.931.0FalseNoneNoneFalseNoneFalse1023.930
3755158141019Nonecode02Providing block level and contour survey of the land proposed for construction, Soil investigation of the proposed for construction, preparation and submission Structural, Design details , Electrical layout, plumbing & sanitary system and all other detailed drawing required for successful completion of the projectJob88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
3755159141019Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soil Depth upto 3 mCum120.36120.36280.0FalseNoneNoneFalseNoneFalse33700.80
3755160141019Nonecode04Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88280.0FalseNoneNoneFalseNoneFalse87886.40
3755161141019Nonecode05Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labor, rolling, water, all materials, usage & all other appurtenances required to complete the work. Deduct 5% cubic meter if rollers are not used and tamping is done manuallyCum559.32559.32380.0FalseNoneNoneFalseNoneFalse212541.60
3755162141019Nonecode06Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6683.526683.5255.0FalseNoneNoneFalseNoneFalse367593.60
3755163141019Nonecode07Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregatesCum7366.747366.7435.0FalseNoneNoneFalseNoneFalse257835.90
3755164141019Nonecode08Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Appendix I - Additionalities for Formwork , centering & Scaffolding for FootingCum8012.158012.1535.0FalseNoneNoneFalseNoneFalse280425.250
3755165141019Nonecode09Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevantIS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse, Aggregates & Shuttering columns Appendix 1 at 70 % of finished rate of Concrete Gr FloorCum13299.7813299.7831.0FalseNoneNoneFalseNoneFalse412293.180
3755166141019Nonecode10Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevantIS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse, Aggregates & Shuttering columns Appendix 1 at 70 % of finished rate of Concrete & Appendix 1- Additionalities for Formwork, Centering & scaffolding For Beam & Lintel centring chages 60 %Cum12517.4412517.4445.0FalseNoneNoneFalseNoneFalse563284.80
3755167141019Nonecode11Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevantIS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse, Aggregates & Shuttering columns Appendix 1 @ 70 % of finished rate of Concrete Appendix 1- Additionalities for Formwork, Centering & scaffolding For Roof centring chages 50 %Cum11735.111735.135.0FalseNoneNoneFalseNoneFalse410728.50
3755168141019Nonecode12do- Chejja Appendix 1- Additionalities for Formwork, Centering & scaffolding For Chajja centring chages 45 %Cum11343.9311343.934.0FalseNoneNoneFalseNoneFalse45375.720
3755169141019Nonecode13do- Chejja Appendix 1- Additionalities for Formwork, Centering & scaffolding For Roof centring chages 50 %Cum11457.3711457.373.0FalseNoneNoneFalseNoneFalse34372.110
3755170141019Nonecode14Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationt105559.26105559.2615.0FalseNoneNoneFalseNoneFalse1583388.90
3755171141019Nonecode15Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in allshapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)including cost of all materials, labour, scaffolding and usage charges ofmachinery & other incidental charges complete as per the direction ofengineer incharge of work.Cum9403.429403.4299.0FalseNoneNoneFalseNoneFalse930938.580
3755172141019Nonecode16Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work.Sqm1218.941218.9430.0FalseNoneNoneFalseNoneFalse36568.20
3755173141019Nonecode17Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as per specifications.Cum162927.32162927.320.9FalseNoneNoneFalseNoneFalse146634.5880
3755174141019Nonecode18Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick one side teak and one side commercialSqm4121.744121.7418.0FalseNoneNoneFalseNoneFalse74191.320
3755175141019Nonecode19Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )Sqm7759.687759.688.0FalseNoneNoneFalseNoneFalse62077.440
3755176141019Nonecode20Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. all floorsKgs577.02577.02300.0FalseNoneNoneFalseNoneFalse173106.00
3755177141019Nonecode21Providing and fixing aluminium work for doors, indows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprenegasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. all floorsKgs630.12630.12245.0FalseNoneNoneFalseNoneFalse154379.40
3755178141019Nonecode22Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. all floorsSqm1381.781381.7860.0FalseNoneNoneFalseNoneFalse82906.80
3755179141019Nonecode23Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge all floorsMtr73.1673.16120.0FalseNoneNoneFalseNoneFalse8779.20
3755180141019Nonecode24Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge all floorsNos84.9684.9660.0FalseNoneNoneFalseNoneFalse5097.60
3755181141019Nonecode25Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal guage) on terraced roof or sunken slabs, laid to slope compacting , including cost of materials, labour, curing, complete as per specifications. all floorsCum2380.062380.068.0FalseNoneNoneFalseNoneFalse19040.480
3755182141019Nonecode26Providing and laying Polished Glazed Vitrified tiles in wall floor and wall with different sizes thickness to be specified by the manufacture ), with water absorption less than .08% and conforming to IS 15622, of approved brand & manufacture, in all colours and shade, laid with cement based high polymer modified quick set tiles adhesive ( water based ) conforming to IS 15477, in average 6mm thickness , including grouting of joints . Ground floor size of tile 600x600Sqm1564.681564.68125.0FalseNoneNoneFalseNoneFalse195585.00
3755183141019Nonecode27Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufactu rer), of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm1049.021049.0220.0FalseNoneNoneFalseNoneFalse20980.40
3755184141019Nonecode28Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mmSqm1386.51386.525.0FalseNoneNoneFalseNoneFalse34662.50
3755185141019Nonecode29Providing and laying flooring and steps fine dressed granite stone slabs 20 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Gr FloorSqm6287.046287.0430.0FalseNoneNoneFalseNoneFalse188611.20
3755186141019Nonecode30Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Gr floorSqm5049.225049.2240.0FalseNoneNoneFalseNoneFalse201968.80
3755187141019Nonecode31Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Inside plasteringSqm348.1348.1120.0FalseNoneNoneFalseNoneFalse41772.00
3755188141019Nonecode32Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Gr floorSqm392.94392.94180.0FalseNoneNoneFalseNoneFalse70729.20
3755189141019Nonecode33do- outside plastering , Building , Flagging , Sump tankSqm392.94392.94150.0FalseNoneNoneFalseNoneFalse58941.00
3755190141019Nonecode34Providing 12 mm cement plaster with Cement mortar 1:4 (1 cement: 4 fine sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal ceilingSqm368.16368.16120.0FalseNoneNoneFalseNoneFalse44179.20
3755191141019Nonecode35Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer inchargeSqm118.0118.0200.0FalseNoneNoneFalseNoneFalse23600.00
3755192141019Nonecode36Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- chargesSqm149.86149.86500.0FalseNoneNoneFalseNoneFalse74930.00
3755193141019Nonecode37Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 ltr/10 sqm over and including one coat of Special primer applied at 0.75 ltr /10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Out sideSqm186.44186.44500.0FalseNoneNoneFalseNoneFalse93220.00
3755194141019Nonecode38Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) including preparing the surface after throughly cleaing oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per direction of Engineer -in- chargeSqm62.5462.5440.0FalseNoneNoneFalseNoneFalse2501.60
3755195141019Nonecode39Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- chargesSqm135.7135.740.0FalseNoneNoneFalseNoneFalse5428.00
3755196141019Nonecode40Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel work including preparing the surface after throughly cleaing oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per direction of Engineer -in- chargeSqm59.059.050.0FalseNoneNoneFalseNoneFalse2950.00
3755197141019Nonecode41Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm197.06197.0650.0FalseNoneNoneFalseNoneFalse9853.00
3755198141019Nonecode42Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation.No6657.566657.566.0FalseNoneNoneFalseNoneFalse39945.360
3755199141019Nonecode43Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet panEach2692.762692.762.0FalseNoneNoneFalseNoneFalse5385.520
3755200141019Nonecode44White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap all floorsUnit3021.983021.982.0FalseNoneNoneFalseNoneFalse6043.960
3755201141019Nonecode45Providing and fixing brass bib cock of approved qualityEach337.48337.488.0FalseNoneNoneFalseNoneFalse2699.840
3755202141019Nonecode46White glazed fire clay kitchen sink of size 600x450x 250 mmNo3517.583517.582.0FalseNoneNoneFalseNoneFalse7035.160
3755203141019Nonecode47Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.No10.6210.622000.0FalseNoneNoneFalseNoneFalse21240.00
3755204141019Nonecode48Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixingthe railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steelmembers shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) includingcost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. all FloorKgs666.7666.7100.0FalseNoneNoneFalseNoneFalse66670.00
3755205141019Nonecode49Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKgs151.04151.04535.0FalseNoneNoneFalseNoneFalse80806.40
3755206141019Nonecode50Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work ( External works) 20 mm diaMtr256.06256.0635.0FalseNoneNoneFalseNoneFalse8962.10
3755207141019Nonecode51do-25 mm diaMtr349.28349.2850.0FalseNoneNoneFalseNoneFalse17464.00
3755208141019Nonecode52do-32 mm diaMtr438.96438.9650.0FalseNoneNoneFalseNoneFalse21948.00
3755209141019Nonecode53Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.75 mm diaMtr341.02341.02100.0FalseNoneNoneFalseNoneFalse34102.00
3755210141019Nonecode54do- 110 mm diaMtr454.3454.350.0FalseNoneNoneFalseNoneFalse22715.00
3755211141019Nonecode55do- 150 mm diaMtr906.24906.2450.0FalseNoneNoneFalseNoneFalse45312.00
3755212141019Nonecode56Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.. 1 HP/ 12 stageNo17287.017287.01.0FalseNoneNoneFalseNoneFalse17287.00
3755213141019Nonecode57Providing and laying reinforced cement concrete pipe of 1.20m dia,0.30 m height for soak pit with including cost of all materials, labour, curing complete as per specificationsNo849.6849.620.0FalseNoneNoneFalseNoneFalse16992.00
3755214141019Nonecode58Providing and laying flooring with RCC slabs 10cms thick, and pointed with cement mortar 1:3, including cost of materials, labour, curing complete as per specifications.No802.4802.41.0FalseNoneNoneFalseNoneFalse802.40
3755215141019Nonecode59Providing and laying reinforced cement concrete pipe of 0.60 m dia,0.30 m height for soak pit with including cost of all materials, labour, curing complete as per specificationsNo489.7489.71.0FalseNoneNoneFalseNoneFalse489.70
3755216141019Nonecode60Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessaryMtr92.0492.04800.0FalseNoneNoneFalseNoneFalse73632.00
3755217141019Nonecode61Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.Mtr34.2234.22350.0FalseNoneNoneFalseNoneFalse11977.00
3755218141019Nonecode62Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switchPoint336.3336.340.0FalseNoneNoneFalseNoneFalse13452.00
3755219141019Nonecode63do- Medium point above 3 mtrs up to 6 mtrs from tapping point to out let via switchPoint464.92464.9225.0FalseNoneNoneFalseNoneFalse11623.00
3755220141019Nonecode64do- Long point above 6M upto 10mtr from tapping point to out let via switchPoint672.6672.620.0FalseNoneNoneFalseNoneFalse13452.00
3755221141019Nonecode65Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 1 SqmmMtr22.4222.42500.0FalseNoneNoneFalseNoneFalse11210.00
3755222141019Nonecode66do- 1.5 SqmmMtr30.6830.68450.0FalseNoneNoneFalseNoneFalse13806.00
3755223141019Nonecode67do- 2.5 SqmmMtr49.5649.56500.0FalseNoneNoneFalseNoneFalse24780.00
3755224141019Nonecode68do- 4 SqmmMtr74.3474.34300.0FalseNoneNoneFalseNoneFalse22302.00
3755225141019Nonecode69Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps Three way scoket.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3755226141019Nonecode70do- 600 watts DimmerEach388.22388.228.0FalseNoneNoneFalseNoneFalse3105.760
3755227141019Nonecode71do- 6Amps Two way switchEach195.88195.8822.0FalseNoneNoneFalseNoneFalse4309.360
3755228141019Nonecode72do- 32 Amps DPEach384.68384.6815.0FalseNoneNoneFalseNoneFalse5770.20
3755229141019Nonecode73do- 6/ 16 Amps universal socketEach278.48278.4820.0FalseNoneNoneFalseNoneFalse5569.60
3755230141019Nonecode74Supplying and fixing of 70/150 watts lamp holder 2 pinEach74.3474.3450.0FalseNoneNoneFalseNoneFalse3717.00
3755231141019Nonecode75Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flaxible copper conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100 Volts. 3 Core x 2.5 SqmmMtr198.24198.24100.0FalseNoneNoneFalseNoneFalse19824.00
3755232141019Nonecode76Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system..48" Sweep (1200 mm) Regular modelEach3521.123521.125.0FalseNoneNoneFalseNoneFalse17605.60
3755233141019Nonecode77Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.785.0FalseNoneNoneFalseNoneFalse1008.90
3755234141019Nonecode78Supplying of box fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube.1 x 4' Tube light fittingEach401.2401.212.0FalseNoneNoneFalseNoneFalse4814.40
3755235141019Nonecode79Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3755236141019Nonecode80Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and(Virgin)PVCinsulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 10C x 1.5 sqmmMtr230.1230.150.0FalseNoneNoneFalseNoneFalse11505.00
3755237141019Nonecode81Supplying and drawing PVC Insulated gas injected physical foam jelly flooded co-oxial TV cable RG-6Mtr51.9251.9250.0FalseNoneNoneFalseNoneFalse2596.00
3755238141019Nonecode82Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and c Type curve indicater ON/OF, energy cros-3 with short circuit breaking capacity of 10k and complete wiring as required confiming to IEC 60898 6-32 A DpEach872.02872.0212.0FalseNoneNoneFalseNoneFalse10464.240
3755239141019Nonecode83Supplying and fixing /replacing of 6/16/32Amps electrical accessories on existing switch board 6Amps 3 pin TopEach102.66102.664.0FalseNoneNoneFalseNoneFalse410.640
3755240141019Nonecode84Supplying and fixing single phase metering panels board , on wall/wood board/ flush mounting using required clamps , bolts, nuts with provision for suitable type capacity MCB's single phase/3 phase / four door with powder coated painting etcEach19883.019883.01.0FalseNoneNoneFalseNoneFalse19883.00
3755241141019Nonecode85Supplying and fixing regular MCB distribution boards on wall/wood board/ flush mounting using required clamps , bolts, nuts with provision for suitable type capacity MCB's single phase/3 phase / single door with powder coated painting 12 way SP & NEach2198.342198.341.0FalseNoneNoneFalseNoneFalse2198.340
3755242141019Nonecode86Supplying and fixing of porcelain fuse channels with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 AmpsEach284.38284.381.0FalseNoneNoneFalseNoneFalse284.380
3755243141019Nonecode87Supplying of1 x 4' feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4' - 20/22 WEach814.2814.226.0FalseNoneNoneFalseNoneFalse21169.20
3755244141019Nonecode88Supplying, fixing, wiring ,earthelectrode forgrounding conduits, I.C.cutout sand othere quipment' sonthemeter board using 40mm dia 2.90mm thick GIpipe2.5mlong buriedinapit. The pit should befilled withequal proportionof saltand charcoal 150mmall-round the pipe to complete depth.Thec onnection from the pipe to the conduitetc .,is to be established through GI wire of size as per lSIspecification 7.3.3.of IS732 using12 mm dia bolts, nuts, washer sand check nut setc., the pipe shall have 16 through holes of 12 mm diaEach4141.84141.81.0FalseNoneNoneFalseNoneFalse4141.80
3755245141019Nonecode89Supplying and fixing flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates , The box should be firmly flush mounted after due groove cutting in Brick/stone/C.C.wall 3 wayNo187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3755246141019Nonecode90do- 4 -5 wayNo208.86208.8630.0FalseNoneNoneFalseNoneFalse6265.80
3755247141019Nonecode91do- 6 wayNo259.6259.68.0FalseNoneNoneFalseNoneFalse2076.80
3755248141019Nonecode92do- 8 wayNo307.98307.9810.0FalseNoneNoneFalseNoneFalse3079.80
3755249141019Nonecode93do-10 to 12 wayNo376.42376.424.0FalseNoneNoneFalseNoneFalse1505.680
3755250141019Nonecode94Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws , bolt nuts etc.No161.66161.668.0FalseNoneNoneFalseNoneFalse1293.280
3755251141019Nonecode95do- 3 ModulerNo189.98189.9845.0FalseNoneNoneFalseNoneFalse8549.10
3755252141019Nonecode96do- 4 ModulerNo206.5206.58.0FalseNoneNoneFalseNoneFalse1652.00
3755253141019Nonecode97do- 6 ModulerNo276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3755254141019Nonecode98do- 8 ModulerNo335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3755255141019Nonecode99do- 10 -12 ModulerNo405.92405.924.0FalseNoneNoneFalseNoneFalse1623.680
3755256141019Nonecode100Electrification Charges for service connection , 2 mmd 3KWNo1534.01534.01.0FalseNoneNoneFalseNoneFalse1534.00
3755257141019Nonecode101do- Registration feeNo236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3755258141019Nonecode102do- Meter costNo1180.01180.01.0FalseNoneNoneFalseNoneFalse1180.00
3755259141019Nonecode103do- Agreement feeNo354.0354.01.0FalseNoneNoneFalseNoneFalse354.00
3755260141019Nonecode104do- Contractor feeNo2360.02360.01.0FalseNoneNoneFalseNoneFalse2360.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17234495270000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17234495270000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17234495270000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17234495270000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17234495270000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17234592040000NoneNoneELIGIBILITYThe rates quoted shall include provision for payment of EPF, ESI and Employees welfare cess as per prevailing GOK ActNone
17234592180000NoneNoneELIGIBILITYthe Contractor should quote the item wise rates Inclusive of GST.None
17234592490000NoneNoneELIGIBILITYThe contractor shall quote item wise rates in the tender and the same shall holds good till the works are completed. The rates should include provision for payment of all Taxes, Royalty or any other such taxes due to the Corporation/Government notified by the Government time to time.None
17234592730000NoneNoneELIGIBILITYThe rates quoted should be inclusive of all leads and lifts for materials etc. The Bidder should visit the work spot at his own cost before quoting his rates.None
17234592970000NoneNoneELIGIBILITYThe contractor shall obtain the necessary license, permission and approved plan on construction of building from the concerned competent authority and local authority if required. Any such charges should be paid by the successful bidder and the same amount will be reimbursed by the BESCOM at later stage.None
17234593150000NoneNoneELIGIBILITYBidders shall produce the original documents uploaded in the KPPP Portal without fail on demand from the BESCOM, the original documents not matching with the uploaded documents shall be liable to rejection.None
17234593240000NoneNoneELIGIBILITYNo materials will be supplied departmentally. The Bidder has to make his own arrangement for procurement of required materials, arranging Electricity, Water supply etc. to complete the work.None
17234593370000NoneNoneELIGIBILITYThe rates/prices quoted by the Bidder shall be firm and no price variation will be admitted.None
17234593450000NoneNoneELIGIBILITYQuantities given in the notification and schedule are approximate and are liable to vary.None
17234593560000NoneNoneELIGIBILITYThe Bids shall remain valid for a period of 90 days from the date of opening of Bid.None
17234593640000NoneNoneELIGIBILITYConditional Bid is liable for rejection without assigning any reasons.None
17234593760000NoneNoneELIGIBILITYThe successful Bidder shall bind himself to abide by the rules and specifications in force and shall execute the necessary agreement on stamp paper within seven days from the date of intimation of acceptance of his Bid, failing which, his Bid will be cancelled unconditionally and his EMD will be forfeited. In addition they would also be responsible for making good the extra expenditure that would be incurred in inviting fresh Bids for the work.None
17234593850000NoneNoneELIGIBILITYThe EMD of the successful bidder will be discharged when the bidder has signed the Agreement and furnished the required Performance Security.None
17234594200000NoneNoneELIGIBILITYFor reserved works, the Security deposit for an amount equivalent to 5% of contract price shall be deducted in every running bill. However, in case of first and final bill the entire security deposit shall be deducted in the final bill.None
17234594380000NoneNoneELIGIBILITYIn case if the bidder intents to quote for more than one work, the capability of the bidder shall be evaluated based on the cumulative financial requirement of all the works quoted. The works will be considered for eligibility, according to serial numbers. For example, if the bidder suffices in two works in the lot as per his financial capability, the works in Sl.no 1 and Sl.no. 2 are considered. Hence, the bidder shall scrupulously quote for the works depending upon his financial capability as above. Otherwise all his quoted bids will be liable for rejection forthwith.None
17234594800000NoneNoneELIGIBILITYThe work should not be sub-let.None
17234594900000NoneNoneELIGIBILITYThe E.M.D. furnished by the unsuccessful bidders will be refunded within 30 days of the end of the tender validity period.None
17234596050000NoneNoneELIGIBILITYThe Bidder has to pay compensation to the disabled or deceased workmen under him for any injury or death caused during the execution of works, failing which the necessary amount will be deducted from the bills and paid to the injured or deceasedNone
17234596190000NoneNoneELIGIBILITYThe Bidder shall submit a PERT CHART indicating date wise programme chalked out to commence all the construction activities against time schedule given and it should be got approved by the Competent authority before commencement of work. It is required for periodical review of progress of work.None
17234596340000NoneNoneELIGIBILITYTime is the essence of contract and the extension to the stipulated period of completion will not be accorded except under unavoidable circumstances. The Bidder has to arrange sufficient men, machinery and materials so that the work can be completed within the stipulated time.None
17234596420000NoneNoneELIGIBILITYBESCOM reserves the right to reject or accept any of the tenders without assigning any reasons.None
17234597020000NoneNoneELIGIBILITYIf the work is not completed and handed over within the agreement period, a penalty of 1% or such smaller amount as the Chief Engineer(Ele) or the other competent authorities(whose decision in writing shall be final) may decide for every day that the work remains un-commenced or unfinished after the agreement period, provided always that the total amount of penalty to be paid under the provision of this clause shall not exceed 7.5% of the total cost of the work as shown in the tender.None
17234597180000NoneNoneELIGIBILITYFor more details, refer attached NIT.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneThe bidder shall upload the work done certificate for having executed any construction work(Original nature) of value not less than 25% of amount put to tender i.e., Rs. 19.85 lakhs and completed satisfactorily as a prime contractor within stipulated time period in the past 5 years (i.e., 2019-20 to 2023-24). Work done certificate shall be duly signed by the officer not below the rank of Executive Engineer or equivalent.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneBidders who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The bidder shall upload his tender capacity calculation in his letter head along with date and signature with Seal. The available tender capacity will be calculated as under, Assessed available tender capacity is (AxNx5.00-B)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tender capacity calculation sheet
NoneNoneNoneNoneThe annual turnover of the bidder shall not be less than the estimated annual payments under this contract i.e., Rs.86.62 lakhs per year in any ONE of the previous 5 financial years (i.e., 2019-20 to 2023-24). Turnover certificate along with Balance sheet and P & L statements of previous 5 financial years for the Civil Engineering works only (i.e.2019-20 to 2023-24) issued from a Registered Chartered Accountant (Registered Chartered Accountant PIN must be mentioned) should be uploaded. For the certificates, UDIN is mandatory.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneThe bidder shall be a Registered KPWD Civil contractor of Class-IV and above. The valid License in original shall be scanned and uploaded.OthersKPWD License
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneThe bidder shall possess valid GST registration number. The original GST Certificate shall be scanned and uploaded.OthersGST registration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneThe bidder shall upload valid original caste certificate (SC) issued by concerned Tahashildar.OthersCaste certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Caste certificate
NoneNoneNoneNoneThe balance sheets and profit loss statements uploaded for two years must tally with Turnover obtained years. The turnover amount will be updated to the FY 2024-25 in which the tenders are invited. The Financial turnover of previous years will be given a weightage of 10% per year to bring them to the price level of the FY 2024-25 in which the tenders are invited. Turnover certificate along with Balance sheet and P & L statements of previous 5 financial years for the Civil Engineering works only (i.e.2019-20 to 2023-24) issued from a Registered Chartered Accountant (Registered Chartered Accountant PIN must be mentioned) should be uploaded. For the certificates, UDIN is mandatory.OthersBalance sheets and PL statements for past 5 years
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Balance sheets and PL statements audited by CA
NoneNoneNoneNoneBidder shall upload the self-declaration affidavit as per the enclosed format on the stamp paper of value not less than Rs. 100.00 duly notarized.Othersself declaration affadavit
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- self declaration affadavit
NoneNoneNoneNoneThe credit facility certificate after this notification date (Bankers certificate as per uploaded format) issued by any Nationalized Bank/Scheduled Indian Bank addressed to the Chief Engineer(Ele), CTAZ, BESCOM, Opp. RTO Office, Turuvanur Road, Chitradurga 577 501 shall be scanned and uploaded in original. (Rs.23.82 lakhs)Othersliquid assets
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Reserved Category CertificateTrueTechnical Bid
Annual Turnover Certificate issued by CATrueTechnical Bid
KPWD LicenceTrueTechnical Bid
Bankers CertificateTrueTechnical Bid
Self Declaration CertificateTrueTechnical Bid
Tender Capacity Calculation SheetTrueTechnical Bid
Balance sheets and PL statements issued by CATrueTechnical Bid
Workdone certificateTrueTechnical Bid
GST registration certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone