3760534 | 141373 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 112.1 | 112.1 | 219.0 | False | None | None | False | None | False | 24549.9 | 0 |
3760535 | 141373 | None | code02 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m but not exceeding 3m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 305.62 | 305.62 | 155.0 | False | None | None | False | None | False | 47371.1 | 0 |
3760536 | 141373 | None | code03 | do- Upto 1.5 m Depth | Cum | 285.56 | 285.56 | 19.0 | False | None | None | False | None | False | 5425.64 | 0 |
3760537 | 141373 | None | code04 | Providing and Filling in foundation with granite / trap broken metal 100mm. anddown size & with approved sand including hand packing, ramming, watering,including cost of all materials and labour with all lead and lift complete as per specification | Cum | 3164.76 | 3164.76 | 12.0 | False | None | None | False | None | False | 37977.12 | 0 |
3760538 | 141373 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6683.52 | 6683.52 | 33.0 | False | None | None | False | None | False | 220556.16 | 0 |
3760539 | 141373 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. for footing | Cum | 8012.15 | 8012.15 | 13.0 | False | None | None | False | None | False | 104157.95 | 0 |
3760540 | 141373 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. forcolumn | Cum | 12611.72 | 12611.72 | 2.0 | False | None | None | False | None | False | 25223.44 | 0 |
3760541 | 141373 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Level Beam | Cum | 12517.44 | 12517.44 | 12.0 | False | None | None | False | None | False | 150209.28 | 0 |
3760542 | 141373 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for GF columns | Cum | 13299.78 | 13299.78 | 3.0 | False | None | None | False | None | False | 39899.34 | 0 |
3760543 | 141373 | None | code10 | do- for GF chejja | Cum | 11343.93 | 11343.93 | 1.0 | False | None | None | False | None | False | 11343.93 | 0 |
3760544 | 141373 | None | code11 | do-for GF lintel, beam, staircase, roof slab and sump | Cum | 11735.1 | 11735.1 | 37.0 | False | None | None | False | None | False | 434198.7 | 0 |
3760545 | 141373 | None | code12 | do- for FF columns | Cum | 13432.78 | 13432.78 | 4.0 | False | None | None | False | None | False | 53731.12 | 0 |
3760546 | 141373 | None | code13 | do- for FF Chejja | Cum | 11457.37 | 11457.37 | 1.0 | False | None | None | False | None | False | 11457.37 | 0 |
3760547 | 141373 | None | code14 | do-for FF lintel, beam, roof slab | Cum | 11852.45 | 11852.45 | 37.0 | False | None | None | False | None | False | 438540.65 | 0 |
3760548 | 141373 | None | code15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 313.88 | 313.88 | 265.0 | False | None | None | False | None | False | 83178.2 | 0 |
3760549 | 141373 | None | code16 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m | Cum | 510.94 | 510.94 | 49.0 | False | None | None | False | None | False | 25036.06 | 0 |
3760550 | 141373 | None | code17 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5percent per cum for every 1.50 m height or part there of | Cum | 559.32 | 559.32 | 114.0 | False | None | None | False | None | False | 63762.48 | 0 |
3760551 | 141373 | None | code18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings for GF | Tonne | 105559.26 | 105559.26 | 5.9 | False | None | None | False | None | False | 622799.634 | 0 |
3760552 | 141373 | None | code19 | do-for FF | Tonne | 106614.85 | 106614.85 | 3.11 | False | None | None | False | None | False | 331572.1835 | 0 |
3760553 | 141373 | None | code20 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 139.24 | 139.24 | 77.0 | False | None | None | False | None | False | 10721.48 | 0 |
3760554 | 141373 | None | code21 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work for GF | Cum | 12952.86 | 12952.86 | 73.0 | False | None | None | False | None | False | 945558.78 | 0 |
3760555 | 141373 | None | code22 | do- for FF | Cum | 13082.39 | 13082.39 | 44.0 | False | None | None | False | None | False | 575625.16 | 0 |
3760556 | 141373 | None | code23 | do- for parapet | Cum | 13211.92 | 13211.92 | 10.0 | False | None | None | False | None | False | 132119.2 | 0 |
3760557 | 141373 | None | code24 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1362.9 | 1362.9 | 26.0 | False | None | None | False | None | False | 35435.4 | 0 |
3760558 | 141373 | None | code25 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. | Sqm | 1376.53 | 1376.53 | 24.0 | False | None | None | False | None | False | 33036.72 | 0 |
3760559 | 141373 | None | code26 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 411.82 | 411.82 | 392.0 | False | None | None | False | None | False | 161433.44 | 0 |
3760560 | 141373 | None | code27 | do-First Floor | Sqm | 415.94 | 415.94 | 357.0 | False | None | None | False | None | False | 148490.58 | 0 |
3760561 | 141373 | None | code28 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge for GF | Sqm | 381.14 | 381.14 | 141.0 | False | None | None | False | None | False | 53740.74 | 0 |
3760562 | 141373 | None | code29 | do- for FF | Sqm | 384.95 | 384.95 | 100.0 | False | None | None | False | None | False | 38495.0 | 0 |
3760563 | 141373 | None | code30 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 454.3 | 454.3 | 295.0 | False | None | None | False | None | False | 134018.5 | 0 |
3760564 | 141373 | None | code31 | do- for FF | Sqm | 458.84 | 458.84 | 315.0 | False | None | None | False | None | False | 144534.6 | 0 |
3760565 | 141373 | None | code32 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment | Mtr | 44.84 | 44.84 | 100.0 | False | None | None | False | None | False | 4484.0 | 0 |
3760566 | 141373 | None | code33 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge | Sqm | 417.72 | 417.72 | 73.0 | False | None | None | False | None | False | 30493.56 | 0 |
3760567 | 141373 | None | code34 | do- for SF | Sqm | 520.97 | 520.97 | 141.0 | False | None | None | False | None | False | 73456.77 | 0 |
3760568 | 141373 | None | code35 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm for GF | Sqm | 1386.5 | 1386.5 | 92.0 | False | None | None | False | None | False | 127558.0 | 0 |
3760569 | 141373 | None | code36 | do- for FF | Sqm | 1400.37 | 1400.37 | 96.0 | False | None | None | False | None | False | 134435.52 | 0 |
3760570 | 141373 | None | code37 | Providing skirting, dadooing, rises of steps with colour glazed glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications fro GF | Sqm | 1709.82 | 1709.82 | 59.0 | False | None | None | False | None | False | 100879.38 | 0 |
3760571 | 141373 | None | code38 | do- for FF | Sqm | 1723.69 | 1723.69 | 49.0 | False | None | None | False | None | False | 84460.81 | 0 |
3760572 | 141373 | None | code39 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete for GF | Sqm | 1269.68 | 1269.68 | 13.0 | False | None | None | False | None | False | 16505.84 | 0 |
3760573 | 141373 | None | code40 | do- for FF | Sqm | 1283.55 | 1283.55 | 11.0 | False | None | None | False | None | False | 14119.05 | 0 |
3760574 | 141373 | None | code41 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 3365.36 | 3365.36 | 27.0 | False | None | None | False | None | False | 90864.72 | 0 |
3760575 | 141373 | None | code42 | Providing and fixing of premium quality Terracota clay tiles for cladding of size 12x2x2 inches with single hole on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. | Sqm | 2319.88 | 2319.88 | 12.0 | False | None | None | False | None | False | 27838.56 | 0 |
3760576 | 141373 | None | code43 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 162927.32 | 162927.32 | 1.0 | False | None | None | False | None | False | 162927.32 | 0 |
3760577 | 141373 | None | code44 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick one side teak and one side commercial. | Sqm | 4598.46 | 4598.46 | 14.0 | False | None | None | False | None | False | 64378.44 | 0 |
3760578 | 141373 | None | code45 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Mtr | 375.24 | 375.24 | 26.0 | False | None | None | False | None | False | 9756.24 | 0 |
3760579 | 141373 | None | code46 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded prelaminated PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top l & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc. ,Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges .with one side prelam | Sqm | 2407.2 | 2407.2 | 8.0 | False | None | None | False | None | False | 19257.6 | 0 |
3760580 | 141373 | None | code47 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc | Kgs | 215.94 | 215.94 | 797.0 | False | None | None | False | None | False | 172104.18 | 0 |
3760581 | 141373 | None | code48 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge . | Kgs | 666.7 | 666.7 | 207.0 | False | None | None | False | None | False | 138006.9 | 0 |
3760582 | 141373 | None | code49 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications..Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates GF | Cum | 7336.06 | 7336.06 | 0.59 | False | None | None | False | None | False | 4328.2754 | 0 |
3760583 | 141373 | None | code50 | do- FF screed | Cum | 7409.42 | 7409.42 | 11.0 | False | None | None | False | None | False | 81503.62 | 0 |
3760584 | 141373 | None | code51 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas /Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at 150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 964.06 | 964.06 | 116.0 | False | None | None | False | None | False | 111830.96 | 0 |
3760585 | 141373 | None | code52 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GF | Sqm | 118.0 | 118.0 | 990.0 | False | None | None | False | None | False | 116820.0 | 0 |
3760586 | 141373 | None | code53 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 L/10 m2 over and including one coat of Special primer applied @ 0.75 L/10 m2 with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50at 60 degree angle with 10 years life). for GF | Sqm | 186.44 | 186.44 | 1600.0 | False | None | None | False | None | False | 298304.0 | 0 |
3760587 | 141373 | None | code54 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 68.44 | 68.44 | 13.0 | False | None | None | False | None | False | 889.72 | 0 |
3760588 | 141373 | None | code55 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90L/10 m2 over an under coat of primer applied at 0.75 L/10 m2 of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 162.84 | 162.84 | 13.0 | False | None | None | False | None | False | 2116.92 | 0 |
3760589 | 141373 | None | code56 | Applying priming coat With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 68.44 | 68.44 | 78.0 | False | None | None | False | None | False | 5338.32 | 0 |
3760590 | 141373 | None | code57 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied at 0.90 ltr/10 m2over an under coat of primer applied @ 0.80 ltr/10 m2 of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.02 | 164.02 | 72.0 | False | None | None | False | None | False | 11809.44 | 0 |
3760591 | 141373 | None | code58 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 7946.12 | 7946.12 | 22.0 | False | None | None | False | None | False | 174814.64 | 0 |
3760592 | 141373 | None | code59 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5746.6 | 5746.6 | 7.0 | False | None | None | False | None | False | 40226.2 | 0 |
3760593 | 141373 | None | code60 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer incharge. (Glazing, paneling and dash fasteners to be paid for separately )For shutters of doors, windows ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kgs | 673.78 | 673.78 | 177.0 | False | None | None | False | None | False | 119259.06 | 0 |
3760594 | 141373 | None | code61 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. completeas per architectural drawings and directions of engineer in charge Prelaminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 1159.94 | 1159.94 | 25.0 | False | None | None | False | None | False | 28998.5 | 0 |
3760595 | 141373 | None | code62 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gaske tetc. complete as per the architectural drawings and the directions of engineer in charge . (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m2) including machinery complete as per specifications.g cost of materials, labour, usage charges of machinery complete as per specifications. | Sqm | 1381.78 | 1381.78 | 25.0 | False | None | None | False | None | False | 34544.5 | 0 |
3760596 | 141373 | None | code63 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C and D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer in charge. | Sqm | 944.0 | 944.0 | 55.0 | False | None | None | False | None | False | 51920.0 | 0 |
3760597 | 141373 | None | code64 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 135011 sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion | Sqm | 4707.02 | 4707.02 | 57.0 | False | None | None | False | None | False | 268300.14 | 0 |
3760598 | 141373 | None | code65 | CUBICLE WORKSTATIONS Providing and fixing CUBICLE WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA powder coated, tile based system for main and return spine, Top tile finish 8 mm thick MDF covered with Fabric of approved colour and one writing board (600 mm W) and one soft board (600 mm W) per work station, Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway-one middle raceway (600 mm W) below table top per workstation and continous raceway at the skirting level, Wire manager - ABS plastic grommet one number per table, Table top - 25 mm thick PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound Hardware-MS powder coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and Table joint plate., as per specifications, drawings and as directed by Engineer in charge.T TYPE 2 wings 3 C) Size: 1500 mm W x 1200mm D x 1200 mm ht | Nos | 45312.0 | 45312.0 | 3.0 | False | None | None | False | None | False | 135936.0 | 0 |
3760599 | 141373 | None | code66 | WATER SUPPLY AND SANITARY Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm indepth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. UPTO 1.5 m | Cum | 571.12 | 571.12 | 27.0 | False | None | None | False | None | False | 15420.24 | 0 |
3760600 | 141373 | None | code67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.Internal work 20mm | m | 447.22 | 447.22 | 30.0 | False | None | None | False | None | False | 13416.6 | 0 |
3760601 | 141373 | None | code68 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25mm | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 |
3760602 | 141373 | None | code69 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 32mm | m | 472.0 | 472.0 | 45.0 | False | None | None | False | None | False | 21240.0 | 0 |
3760603 | 141373 | None | code70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm | m | 632.48 | 632.48 | 45.0 | False | None | None | False | None | False | 28461.6 | 0 |
3760604 | 141373 | None | code71 | Providing and laying cinder concrete in cement 1:15 (1 cement :15 Cinder of 12.5mm nomonal gauge ) on terraced roof or sunken slabs, laid to slope compacting, including cost of all materials , labour curing as per specifications | Cum | 2380.06 | 2380.06 | 3.0 | False | None | None | False | None | False | 7140.18 | 0 |
3760605 | 141373 | None | code72 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 80mm | m | 795.32 | 795.32 | 45.0 | False | None | None | False | None | False | 35789.4 | 0 |
3760606 | 141373 | None | code73 | Providing and fixing to wall, ceiling and floor, medium density polyethylene pipes 6.00 kgf/sq.cm working pressure 110mm dia outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications 100 mm | m | 1097.4 | 1097.4 | 35.0 | False | None | None | False | None | False | 38409.0 | 0 |
3760607 | 141373 | None | code74 | do- 150 mm nominal dia Pipes | m | 1879.74 | 1879.74 | 40.0 | False | None | None | False | None | False | 75189.6 | 0 |
3760608 | 141373 | None | code75 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc.complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Each | 6657.56 | 6657.56 | 6.0 | False | None | None | False | None | False | 39945.36 | 0 |
3760609 | 141373 | None | code76 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size),foundaggregate 40 mm nominal size), inside plastering 12 mm thick with ation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stonecement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coatof neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (lightduty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 | Each | 12467.88 | 12467.88 | 1.0 | False | None | None | False | None | False | 12467.88 | 0 |
3760610 | 141373 | None | code77 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover 180 x 150 mm size P type & With Non Modular common burnt clay bricks of designation 3.5 & frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design | No | 3169.48 | 3169.48 | 2.0 | False | None | None | False | None | False | 6338.96 | 0 |
3760611 | 141373 | None | code78 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 |
3760612 | 141373 | None | code79 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Each | 5255.72 | 5255.72 | 3.0 | False | None | None | False | None | False | 15767.16 | 0 |
3760613 | 141373 | None | code80 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: : White itreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3636.76 | 3636.76 | 5.0 | False | None | None | False | None | False | 18183.8 | 0 |
3760614 | 141373 | None | code81 | Providing and fixing vitreous china dual purpose closet suitable foruse as squatting pan or European type water closet (Anglo Indian W.Cpan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. | Each | 10197.56 | 10197.56 | 5.0 | False | None | None | False | None | False | 50987.8 | 0 |
3760615 | 141373 | None | code82 | Providing and fixing brass bib cock of approved quality 20 mm nominal bore | Each | 359.9 | 359.9 | 15.0 | False | None | None | False | None | False | 5398.5 | 0 |
3760616 | 141373 | None | code83 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : : 32 mm nominal bore | Each | 705.64 | 705.64 | 5.0 | False | None | None | False | None | False | 3528.2 | 0 |
3760617 | 141373 | None | code84 | Providing and fixing Towel rail 600mm length with hooks made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy | Each | 3702.84 | 3702.84 | 5.0 | False | None | None | False | None | False | 18514.2 | 0 |
3760618 | 141373 | None | code85 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately For 3000 Ltr | Each | 10.62 | 10.62 | 1000.0 | False | None | None | False | None | False | 10620.0 | 0 |
3760619 | 141373 | None | code86 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 343.38 | 343.38 | 77.0 | False | None | None | False | None | False | 26440.26 | 0 |
3760620 | 141373 | None | code87 | ELECTRIFICATION Supplying heavy gauge PVC conduit pipe 25mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws | m | 95.58 | 95.58 | 90.0 | False | None | None | False | None | False | 8602.2 | 0 |
3760621 | 141373 | None | code88 | Supplying heavy gauge PVC conduit pipe 32mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | m | 125.08 | 125.08 | 75.0 | False | None | None | False | None | False | 9381.0 | 0 |
3760622 | 141373 | None | code89 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | m | 34.22 | 34.22 | 250.0 | False | None | None | False | None | False | 8555.0 | 0 |
3760623 | 141373 | None | code90 | Supplying PVC flexible conduit pipe 20 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mm | m | 22.42 | 22.42 | 150.0 | False | None | None | False | None | False | 3363.0 | 0 |
3760624 | 141373 | None | code91 | Supplying PVC flexible conduit pipe 25 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm | m | 25.96 | 25.96 | 100.0 | False | None | None | False | None | False | 2596.0 | 0 |
3760625 | 141373 | None | code92 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 |
3760626 | 141373 | None | code93 | do- 4-5 Way | Each | 208.86 | 208.86 | 8.0 | False | None | None | False | None | False | 1670.88 | 0 |
3760627 | 141373 | None | code94 | do- 6 Way | Each | 259.6 | 259.6 | 10.0 | False | None | None | False | None | False | 2596.0 | 0 |
3760628 | 141373 | None | code95 | do- 8 Way | Each | 307.98 | 307.98 | 12.0 | False | None | None | False | None | False | 3695.76 | 0 |
3760629 | 141373 | None | code96 | do- 10-12 Way | Each | 376.42 | 376.42 | 12.0 | False | None | None | False | None | False | 4517.04 | 0 |
3760630 | 141373 | None | code97 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2198.34 | 2198.34 | 2.0 | False | None | None | False | None | False | 4396.68 | 0 |
3760631 | 141373 | None | code98 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm | m | 30.68 | 30.68 | 540.0 | False | None | None | False | None | False | 16567.2 | 0 |
3760632 | 141373 | None | code99 | do- 2.5 sqmm | m | 49.56 | 49.56 | 450.0 | False | None | None | False | None | False | 22302.0 | 0 |
3760633 | 141373 | None | code100 | do- 4 sqmm | m | 74.34 | 74.34 | 250.0 | False | None | None | False | None | False | 18585.0 | 0 |
3760634 | 141373 | None | code101 | do- 6 sqmm | m | 108.56 | 108.56 | 180.0 | False | None | None | False | None | False | 19540.8 | 0 |
3760635 | 141373 | None | code102 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose ength in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 317.42 | 317.42 | 40.0 | False | None | None | False | None | False | 12696.8 | 0 |
3760636 | 141373 | None | code103 | do- Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 447.22 | 447.22 | 25.0 | False | None | None | False | None | False | 11180.5 | 0 |
3760637 | 141373 | None | code104 | do- Long point above 6Mtr upto 10Mtr from tapping point to out let vias witch box | Point | 654.9 | 654.9 | 20.0 | False | None | None | False | None | False | 13098.0 | 0 |
3760638 | 141373 | None | code105 | do- Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches | Point | 798.86 | 798.86 | 6.0 | False | None | None | False | None | False | 4793.16 | 0 |
3760639 | 141373 | None | code106 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694 1990 3C x 6 mm2 | m | 289.1 | 289.1 | 80.0 | False | None | None | False | None | False | 23128.0 | 0 |
3760640 | 141373 | None | code107 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 10C x 4 mm2 | m | 574.66 | 574.66 | 30.0 | False | None | None | False | None | False | 17239.8 | 0 |
3760641 | 141373 | None | code108 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 161.66 | 161.66 | 10.0 | False | None | None | False | None | False | 1616.6 | 0 |
3760642 | 141373 | None | code109 | do- 4 Module | Each | 206.5 | 206.5 | 12.0 | False | None | None | False | None | False | 2478.0 | 0 |
3760643 | 141373 | None | code110 | do- 6 Module | Each | 276.12 | 276.12 | 12.0 | False | None | None | False | None | False | 3313.44 | 0 |
3760644 | 141373 | None | code111 | do- 8 Module | Each | 335.12 | 335.12 | 12.0 | False | None | None | False | None | False | 4021.44 | 0 |
3760645 | 141373 | None | code112 | do-10-12 Module | Each | 405.92 | 405.92 | 10.0 | False | None | None | False | None | False | 4059.2 | 0 |
3760646 | 141373 | None | code113 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 120.36 | 120.36 | 25.0 | False | None | None | False | None | False | 3009.0 | 0 |
3760647 | 141373 | None | code114 | do- 6 Amps Two way switch | Each | 195.88 | 195.88 | 5.0 | False | None | None | False | None | False | 979.4 | 0 |
3760648 | 141373 | None | code115 | do- 6A Three Way socket | Each | 201.78 | 201.78 | 22.0 | False | None | None | False | None | False | 4439.16 | 0 |
3760649 | 141373 | None | code116 | do-Stepped Fan Regulator Two Module | Each | 421.26 | 421.26 | 12.0 | False | None | None | False | None | False | 5055.12 | 0 |
3760650 | 141373 | None | code117 | do- 6A Bell Push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 |
3760651 | 141373 | None | code118 | do-32A DP Switch | Each | 384.68 | 384.68 | 2.0 | False | None | None | False | None | False | 769.36 | 0 |
3760652 | 141373 | None | code119 | do- 6/16A Universal Socket | Each | 278.48 | 278.48 | 6.0 | False | None | None | False | None | False | 1670.88 | 0 |
3760653 | 141373 | None | code120 | do- V / Telephone socket | Each | 184.08 | 184.08 | 12.0 | False | None | None | False | None | False | 2208.96 | 0 |
3760654 | 141373 | None | code121 | do- RJ45/I.O Outlet Cat-6 | Each | 397.66 | 397.66 | 12.0 | False | None | None | False | None | False | 4771.92 | 0 |
3760655 | 141373 | None | code122 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Nos | 489.7 | 489.7 | 16.0 | False | None | None | False | None | False | 7835.2 | 0 |
3760656 | 141373 | None | code123 | do- 6-32Amps DP | Nos | 872.02 | 872.02 | 10.0 | False | None | None | False | None | False | 8720.2 | 0 |
3760657 | 141373 | None | code124 | do- 50-63 A DP | No | 1300.36 | 1300.36 | 6.0 | False | None | None | False | None | False | 7802.16 | 0 |
3760658 | 141373 | None | code125 | Fabricating supplying and mounting MS box made out 14SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 25000.0 | False | None | None | False | None | False | 14750.0 | 0 |
3760659 | 141373 | None | code126 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240Vat 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2- 20/22 W | Each | 650.18 | 650.18 | 8.0 | False | None | None | False | None | False | 5201.44 | 0 |
3760660 | 141373 | None | code127 | do-LED light fitting 1 x 4- 9/10W | Each | 814.2 | 814.2 | 8.0 | False | None | None | False | None | False | 6513.6 | 0 |
3760661 | 141373 | None | code128 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076inch twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / Girder | Each | 143.96 | 143.96 | 16.0 | False | None | None | False | None | False | 2303.36 | 0 |
3760662 | 141373 | None | code129 | Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70. efficacy 100 lumen per W, 120degree beam spread, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1x1 24Watt | Each | 4356.56 | 4356.56 | 18.0 | False | None | None | False | None | False | 78418.08 | 0 |
3760663 | 141373 | None | code130 | Supplying of recess mounting non integrated type LED down light 10-12 W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should5% of lamp Wage, short circuit & open circuit protection
to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.10-12w | Each | 1497.42 | 1497.42 | 12.0 | False | None | None | False | None | False | 17969.04 | 0 |
3760664 | 141373 | None | code131 | Supply of LED Streetlight luminaire with pressure die castaluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical ompartment and impact resistance of complete luminaire IK08. Power Factor 0.9 withmains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598,LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 90W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED steetlight 90watts | Each | 10454.8 | 10454.8 | 4.0 | False | None | None | False | None | False | 41819.2 | 0 |
3760665 | 141373 | None | code132 | Fabricating, supplying and erection of ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 5 m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom .Top 70 mm and Bottom 130 mm dia with 3 mm thick, suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended 5 m - Top 70 mm and Bottom 130 mm dia | Each | 11682.0 | 11682.0 | 2.0 | False | None | None | False | None | False | 23364.0 | 0 |
3760666 | 141373 | None | code133 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiringusing suitable capacity wires. Using2mlong19mm18SWGenamelledbraisedconduitoftwonos. rod pendent with ball socket with check nuts all nickel plated | Each | 672.6 | 672.6 | 4.0 | False | None | None | False | None | False | 2690.4 | 0 |
3760667 | 141373 | None | code134 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply | Each | 1760.56 | 1760.56 | 6.0 | False | None | None | False | None | False | 10563.36 | 0 |
3760668 | 141373 | None | code135 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire | Each | 580.56 | 580.56 | 6.0 | False | None | None | False | None | False | 3483.36 | 0 |
3760669 | 141373 | None | code136 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 3521.12 | 3521.12 | 11.0 | False | None | None | False | None | False | 38732.32 | 0 |
3760670 | 141373 | None | code137 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 11.0 | False | None | None | False | None | False | 2219.58 | 0 |
3760671 | 141373 | None | code138 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 11.0 | False | None | None | False | None | False | 2557.06 | 0 |
3760672 | 141373 | None | code139 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm . Using 4ft. Copper bonded rod with backfill compound | Each | 5343.04 | 5343.04 | 5.0 | False | None | None | False | None | False | 26715.2 | 0 |
3760673 | 141373 | None | code140 | GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm GI strip. | m | 96.76 | 96.76 | 25.0 | False | None | None | False | None | False | 2419.0 | 0 |
3760674 | 141373 | None | code141 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 10991.7 | 10991.7 | 1.0 | False | None | None | False | None | False | 10991.7 | 0 |
3760675 | 141373 | None | code142 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63A | Each | 473.18 | 473.18 | 4.0 | False | None | None | False | None | False | 1892.72 | 0 |
3760676 | 141373 | None | code143 | Fixing all types and all capacities of fluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076 inch twin twisted PVC insulated wires, required Nos of round blocks and clamps.Using 2 m long 19mm 18 SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickelplated | Each | 672.6 | 672.6 | 46.0 | False | None | None | False | None | False | 30939.6 | 0 |
3760677 | 141373 | None | code144 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 300.0 | False | None | None | False | None | False | 13452.0 | 0 |
3760678 | 141373 | None | code145 | Supplying,erecting,testing&commissioningofONLINEUPSsystemsuitableforoperationon230V,50Hz,A/Csupply,withisolationtransformerallaccessoriescompleteandExcludingbatteriesand wiring complete | Each | 45688.42 | 45688.42 | 1.0 | False | None | None | False | None | False | 45688.42 | 0 |
3760679 | 141373 | None | code146 | Supplying,installation,testing&commissioningof12VDC,AHbatteriesinpolypropylenecontainerforU.P.S.Sealedmaintenancefree batteries | Each | 14667.4 | 14667.4 | 2.0 | False | None | None | False | None | False | 29334.8 | 0 |
3760680 | 141373 | None | code147 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments, 2 HP, Size 65x50 Head 13M, Discharge 462 LPM | Each | 18419.8 | 18419.8 | 1.0 | False | None | None | False | None | False | 18419.8 | 0 |
3760681 | 141373 | None | code148 | Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.Upto 7.5 HP centrifugal pump | Each | 11210.0 | 11210.0 | 1.0 | False | None | None | False | None | False | 11210.0 | 0 |
3760682 | 141373 | None | code149 | COUMPOUND WALL Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 285.56 | 285.56 | 114.0 | False | None | None | False | None | False | 32553.84 | 0 |
3760683 | 141373 | None | code150 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6683.52 | 6683.52 | 25.0 | False | None | None | False | None | False | 167088.0 | 0 |
3760684 | 141373 | None | code151 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. | Cum | 8012.15 | 8012.15 | 8.0 | False | None | None | False | None | False | 64097.2 | 0 |
3760685 | 141373 | None | code152 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Addendum ) | Cum | 12611.72 | 12611.72 | 3.0 | False | None | None | False | None | False | 37835.16 | 0 |
3760686 | 141373 | None | code153 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates compound beam | Cum | 11735.1 | 11735.1 | 12.0 | False | None | None | False | None | False | 140821.2 | 0 |
3760687 | 141373 | None | code154 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates compound column | Cum | 13299.78 | 13299.78 | 5.0 | False | None | None | False | None | False | 66498.9 | 0 |
3760688 | 141373 | None | code155 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 105559.26 | 105559.26 | 0.64 | False | None | None | False | None | False | 67557.9264 | 0 |
3760689 | 141373 | None | code156 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I)2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1545.8 | 1545.8 | 225.0 | False | None | None | False | None | False | 347805.0 | 0 |
3760690 | 141373 | None | code157 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 454.3 | 454.3 | 609.0 | False | None | None | False | None | False | 276668.7 | 0 |
3760691 | 141373 | None | code158 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc | Kgs | 215.94 | 215.94 | 450.0 | False | None | None | False | None | False | 97173.0 | 0 |
3760692 | 141373 | None | code159 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m2 with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) | Sqm | 186.44 | 186.44 | 609.0 | False | None | None | False | None | False | 113541.96 | 0 |
3760693 | 141373 | None | code160 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m2 over an under coat of primer applied @ 0.80 ltr/10 m2 of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 164.02 | 164.02 | 22.0 | False | None | None | False | None | False | 3608.44 | 0 |
3760694 | 141373 | None | code161 | VEHICLE STAND Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 285.56 | 285.56 | 4.0 | False | None | None | False | None | False | 1142.24 | 0 |
3760695 | 141373 | None | code162 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6683.52 | 6683.52 | 9.0 | False | None | None | False | None | False | 60151.68 | 0 |
3760696 | 141373 | None | code163 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications | Cum | 7418.66 | 7418.66 | 7.0 | False | None | None | False | None | False | 51930.62 | 0 |
3760697 | 141373 | None | code164 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1545.8 | 1545.8 | 5.0 | False | None | None | False | None | False | 7729.0 | 0 |
3760698 | 141373 | None | code165 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge | Sqm | 417.72 | 417.72 | 64.0 | False | None | None | False | None | False | 26734.08 | 0 |
3760699 | 141373 | None | code166 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m2 of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.02 | 164.02 | 17.0 | False | None | None | False | None | False | 2788.34 | 0 |
3760700 | 141373 | None | code167 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 173.46 | 173.46 | 720.0 | False | None | None | False | None | False | 124891.2 | 0 |
3760701 | 141373 | None | code168 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 ) total coated thickness with zinc coating 120 g/m2 as per IS 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required | Sqm | 670.24 | 670.24 | 60.0 | False | None | None | False | None | False | 40214.4 | 0 |
3760702 | 141373 | None | code169 | DISMANTLING WORKS Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar | Cum | 1214.22 | 1214.22 | 93.0 | False | None | None | False | None | False | 112922.46 | 0 |
3760703 | 141373 | None | code170 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge In cement mortar | Cum | 1987.12 | 1987.12 | 39.0 | False | None | None | False | None | False | 77497.68 | 0 |
3760704 | 141373 | None | code171 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 2862.68 | 2862.68 | 10.0 | False | None | None | False | None | False | 28626.8 | 0 |
3760705 | 141373 | None | code172 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1962.34 | 1962.34 | 15.0 | False | None | None | False | None | False | 29435.1 | 0 |
3760706 | 141373 | None | code173 | Shifting of debris to a distance of 5KM to 10 km with all lead and lift, labour complete | Cum | 413.0 | 413.0 | 157.0 | False | None | None | False | None | False | 64841.0 | 0 |
3760707 | 141373 | None | code174 | APPROACH ROAD Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 3019.62 | 3019.62 | 12.0 | False | None | None | False | None | False | 36235.44 | 0 |
3760708 | 141373 | None | code175 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing | Cum | 5805.6 | 5805.6 | 12.0 | False | None | None | False | None | False | 69667.2 | 0 |
3760709 | 141373 | None | code176 | Construction of M30 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with OPC 270 kg/m3 and GGBS@ 90 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plantas per approved mix design transported to site, laid with apaver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion,membrane, sealant primer, joint sealant, debonding strip, dowelbar, tie rod, admixtures, curing compound, steel channels,finishing to lines and grades as per drawing. | Cum | 9250.02 | 9250.02 | 14.0 | False | None | None | False | None | False | 129500.28 | 0 |
3760710 | 141373 | None | code177 | SINKING OF BOREWELL Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. | Nos | 6239.84 | 6239.84 | 1.0 | False | None | None | False | None | False | 6239.84 | 0 |
3760711 | 141373 | None | code178 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes ,collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50m | m | 436.6 | 436.6 | 50.0 | False | None | None | False | None | False | 21830.0 | 0 |
3760712 | 141373 | None | code179 | Borewell depth of 50 to 100m | m | 547.52 | 547.52 | 50.0 | False | None | None | False | None | False | 27376.0 | 0 |
3760713 | 141373 | None | code180 | Borewell depth of 100 to 150m | m | 581.74 | 581.74 | 50.0 | False | None | None | False | None | False | 29087.0 | 0 |
3760714 | 141373 | None | code181 | Borewell depth of 150 to 200m | m | 674.96 | 674.96 | 50.0 | False | None | None | False | None | False | 33748.0 | 0 |
3760715 | 141373 | None | code182 | Borewell depth of 200 to 250m | m | 791.78 | 791.78 | 50.0 | False | None | None | False | None | False | 39589.0 | 0 |
3760716 | 141373 | None | code183 | Borewell depth of 250 to 300m | m | 873.2 | 873.2 | 50.0 | False | None | None | False | None | False | 43660.0 | 0 |
3760717 | 141373 | None | code184 | Borewell depth of 300 to 350m | m | 1024.24 | 1024.24 | 25.0 | False | None | None | False | None | False | 25606.0 | 0 |
3760718 | 141373 | None | code185 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2280.94 | 2280.94 | 40.0 | False | None | None | False | None | False | 91237.6 | 0 |
3760719 | 141373 | None | code186 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Each | 177.0 | 177.0 | 7.0 | False | None | None | False | None | False | 1239.0 | 0 |
3760720 | 141373 | None | code187 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by engineer in charge | Each | 193.52 | 193.52 | 1.0 | False | None | None | False | None | False | 193.52 | 0 |
3760721 | 141373 | None | code188 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and 50 mm pipe | Nos | 3599.0 | 3599.0 | 23.0 | False | None | None | False | None | False | 82777.0 | 0 |
3760722 | 141373 | None | code189 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034 2000 specifications, to work site with testing of as per instructions of engineer incharge of work and Latest amendments complete 3.00 HP 2.2KW 9 STG | Each | 23733.34 | 23733.34 | 1.0 | False | None | None | False | None | False | 23733.34 | 0 |
3760723 | 141373 | None | code190 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm | m | 218.3 | 218.3 | 300.0 | False | None | None | False | None | False | 65490.0 | 0 |
3760724 | 141373 | None | code191 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of SD Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type complete.6 to 15 HP pumps | Each | 18762.0 | 18762.0 | 1.0 | False | None | None | False | None | False | 18762.0 | 0 |
3760725 | 141373 | None | code192 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 7670.0 | 7670.0 | 1.0 | False | None | None | False | None | False | 7670.0 | 0 |
3760726 | 141373 | None | code193 | structural design and drawings report as per direction of engineer incharge | Job | 118000.0 | 118000.0 | 1.0 | False | None | None | False | None | False | 118000.0 | 0 |