createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723530362524
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1250.00
emd100000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-08-2024 17:00:00
tenderQueryClose27-08-2024 17:00:00
technicalBidOpen30-08-2024 11:00:00
publishedDate13-08-2024 16:18:13
publishedByPostBESCOM_CE_CTAZ_CTD
publishedByUserKPE19796 - M ROMARAJU
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER CIVIL
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08194230088
mobileNumber9448094835
tenderSupplierListNone
tenderSchedule
createdTs1723530362564
version4
createdDateNone
modifiedDateNone
tenderNumberBESCOM/2024-25/BD/WORK_INDENT185
titleConstruction of Transformer repair center at BESCOM Premises in Turuvekere.
descriptionConstruction of Transformer repair center at BESCOM Premises in Turuvekere.
categoryWORKS
categoryTextWorks
ecv5000000.00
deptNameBangalore Electricity Supply Company Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3788
locationNameBESCOM Chitradurga Area Zone(CTAZ) Office Bengaluru
provisionalAmount5000000.0
groupOverheadTotal98.13
fileNumberCEE/CZ/EEC/24-25/LOT1/KW3-2/CALL-2
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17235303630000NoneNoneBuildingsConstruction of Transformer repair center at BESCOM Premises in Turuvekere.4999901.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3763653141583Nonecode01Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m.Sqm673.33673.3385.0FalseNoneNoneFalseNoneFalse57233.050
3763654141583Nonecode02Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinary/soft rock (without requiring blasting).Cum551.79551.7973.0FalseNoneNoneFalseNoneFalse40280.670
3763655141583Nonecode03Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work In Ordinary/Soft rock upto 300 mm depth.Cum439.97439.9762.0FalseNoneNoneFalseNoneFalse27278.140
3763656141583Nonecode04Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per cum for every 1.50 m height or part there ofCum576.1576.1180.0FalseNoneNoneFalseNoneFalse103698.00
3763657141583Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6884.036884.0395.0FalseNoneNoneFalseNoneFalse653982.850
3763658141583Nonecode06Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer inchargeSqm972.32972.32251.0FalseNoneNoneFalseNoneFalse244052.320
3763659141583Nonecode07Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for FootingCum8252.528252.5214.0FalseNoneNoneFalseNoneFalse115535.280
3763660141583Nonecode08do-ColumnCum12990.0712990.0710.5FalseNoneNoneFalseNoneFalse136395.7350
3763661141583Nonecode09do-LintelsCum12225.9512225.952.0FalseNoneNoneFalseNoneFalse24451.90
3763662141583Nonecode10do-BeamsCum12225.9512225.9517.0FalseNoneNoneFalseNoneFalse207841.150
3763663141583Nonecode11do- retaining wallCum11461.8311461.8311.5FalseNoneNoneFalseNoneFalse131811.0450
3763664141583Nonecode12Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.Cum8101.868101.863.5FalseNoneNoneFalseNoneFalse28356.510
3763665141583Nonecode13Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired densityCum3110.213110.2148.0FalseNoneNoneFalseNoneFalse149290.080
3763666141583Nonecode14Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1592.171592.17108.0FalseNoneNoneFalseNoneFalse171954.360
3763667141583Nonecode15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Scaffolding charges added. ( For Chejja concrete)Cum11079.7711079.771.0FalseNoneNoneFalseNoneFalse11079.770
3763668141583Nonecode16Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in ement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum13341.4513341.4548.0FalseNoneNoneFalseNoneFalse640389.60
3763669141583Nonecode17Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workSqm1219.051219.0513.0FalseNoneNoneFalseNoneFalse15847.650
3763670141583Nonecode18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne108726.04108726.042.9FalseNoneNoneFalseNoneFalse315305.5160
3763671141583Nonecode19Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kgs204.19204.19185.0FalseNoneNoneFalseNoneFalse37775.150
3763672141583Nonecode20Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Kgs178.66178.661490.0FalseNoneNoneFalseNoneFalse266203.40
3763673141583Nonecode21Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm690.35690.35240.0FalseNoneNoneFalseNoneFalse165684.00
3763674141583Nonecode22Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm450.91450.91570.0FalseNoneNoneFalseNoneFalse257018.70
3763675141583Nonecode23Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-chargeSqm392.57392.57210.0FalseNoneNoneFalseNoneFalse82439.70
3763676141583Nonecode24Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm3200.153200.1513.0FalseNoneNoneFalseNoneFalse41601.950
3763677141583Nonecode25Providing and fixing ball bearing for rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Nos489.81489.814.0FalseNoneNoneFalseNoneFalse1959.240
3763678141583Nonecode26wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations the which ever parts unserviceable should be replace (Springs, wheels, Shaft & replace the leafs which corroded) new one with all necessary including cost of materials, labour, complete as per specifications including cost of all materials, with all leadm611.35611.353.5FalseNoneNoneFalseNoneFalse2139.7250
3763679141583Nonecode27Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm430.25430.2555.0FalseNoneNoneFalseNoneFalse23663.750
3763680141583Nonecode28Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.Sqm2005.412005.4140.0FalseNoneNoneFalseNoneFalse80216.40
3763681141583Nonecode29Providing and fixing Pre-Cast concrete Soak pit ringsNos1180.01180.06.0FalseNoneNoneFalseNoneFalse7080.00
3763682141583Nonecode30Providing and fixing Pre-Cast concrete Soak pit CoverNos1416.01416.01.0FalseNoneNoneFalseNoneFalse1416.00
3763683141583Nonecode31Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m2 over and including one coat of Special primer applied @ 0.75 L/10 m2 with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm192.03192.03575.0FalseNoneNoneFalseNoneFalse110417.250
3763684141583Nonecode32Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m2 over an under coat of primer applied @ 0.80 ltr/10 m2 of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm168.94168.9465.0FalseNoneNoneFalseNoneFalse10981.10
3763685141583Nonecode33Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. completeKgs170.16170.16250.0FalseNoneNoneFalseNoneFalse42540.00
3763686141583Nonecode34Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thickMtr125.08125.0860.0FalseNoneNoneFalseNoneFalse7504.80
3763687141583Nonecode35Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 10C x 4 mm2Mtr574.66574.6640.0FalseNoneNoneFalseNoneFalse22986.40
3763688141583Nonecode36do- 10C x 2.5 mmMtr506.22506.2220.0FalseNoneNoneFalseNoneFalse10124.40
3763689141583Nonecode37Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wallMtr34.2234.22300.0FalseNoneNoneFalseNoneFalse10266.00
3763690141583Nonecode38Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mmMtr25.9625.9660.0FalseNoneNoneFalseNoneFalse1557.60
3763691141583Nonecode39Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rodNo188.8188.820.0FalseNoneNoneFalseNoneFalse3776.00
3763692141583Nonecode40Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose ength in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxPoint317.42317.4230.0FalseNoneNoneFalseNoneFalse9522.60
3763693141583Nonecode41do- Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint447.22447.2250.0FalseNoneNoneFalseNoneFalse22361.00
3763694141583Nonecode42do- Long point above 6Mtr upto 10Mtr from tapping point to out let vias witch boxPoint654.9654.970.0FalseNoneNoneFalseNoneFalse45843.00
3763695141583Nonecode43do-Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switchesPoint798.86798.868.0FalseNoneNoneFalseNoneFalse6390.880
3763696141583Nonecode44Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mmMtr30.6830.681100.0FalseNoneNoneFalseNoneFalse33748.00
3763697141583Nonecode45do- 2.5 mmMtr49.5649.561800.0FalseNoneNoneFalseNoneFalse89208.00
3763698141583Nonecode46do- 4 sqmmMtr74.3474.34300.0FalseNoneNoneFalseNoneFalse22302.00
3763699141583Nonecode47do- 6 sqmmMtr108.56108.5675.0FalseNoneNoneFalseNoneFalse8142.00
3763700141583Nonecode48Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 4 mm2Mtr198.24198.2430.0FalseNoneNoneFalseNoneFalse5947.20
3763701141583Nonecode49Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 WayEach187.62187.6215.0FalseNoneNoneFalseNoneFalse2814.30
3763702141583Nonecode50do- 4-5 WayEach208.86208.8615.0FalseNoneNoneFalseNoneFalse3132.90
3763703141583Nonecode51do- 8 WayEach307.98307.9830.0FalseNoneNoneFalseNoneFalse9239.40
3763704141583Nonecode52do- 10-12 WayEach376.42376.4225.0FalseNoneNoneFalseNoneFalse9410.50
3763705141583Nonecode53Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleEach161.66161.6615.0FalseNoneNoneFalseNoneFalse2424.90
3763706141583Nonecode54do- 4 ModuleEach206.5206.515.0FalseNoneNoneFalseNoneFalse3097.50
3763707141583Nonecode55do- 8 ModuleEach335.12335.1230.0FalseNoneNoneFalseNoneFalse10053.60
3763708141583Nonecode56do- 10-12 ModuleEach405.92405.9225.0FalseNoneNoneFalseNoneFalse10148.00
3763709141583Nonecode57Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach120.36120.36125.0FalseNoneNoneFalseNoneFalse15045.00
3763710141583Nonecode58do- 6 Amps Two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3763711141583Nonecode59do- 6A Three Way socketEach201.78201.7860.0FalseNoneNoneFalseNoneFalse12106.80
3763712141583Nonecode60do- Stepped Fan Regulator Two ModuleEach421.26421.2620.0FalseNoneNoneFalseNoneFalse8425.20
3763713141583Nonecode61do- 6/16A Universal SocketEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3763714141583Nonecode62Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 poleEach6543.16543.14.0FalseNoneNoneFalseNoneFalse26172.40
3763715141583Nonecode63Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.727.0FalseNoneNoneFalseNoneFalse13221.90
3763716141583Nonecode64do- 6-32Amps DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3763717141583Nonecode65do- 50-63 A DPEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3763718141583Nonecode66Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & NEach2198.342198.345.0FalseNoneNoneFalseNoneFalse10991.70
3763719141583Nonecode67Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4 20/22 WEach814.2814.275.0FalseNoneNoneFalseNoneFalse61065.00
3763720141583Nonecode68do- LED light fitting 1 x 2' - 9/10WEach650.18650.1810.0FalseNoneNoneFalseNoneFalse6501.80
3763721141583Nonecode69Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast extruded aluminum housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy100 lumen per W, 120degree beam spread, life25000 burning hours and Compliance to IS 10322/IEC 60598,LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly with PF 0.95 power loss should 5% of lamp Wage short circuit & open circuit protection to be integrated in the circuit, THD less than 20% Life as per LM 79. The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1x1 feet 24WattEach4356.564356.566.0FalseNoneNoneFalseNoneFalse26139.360
3763722141583Nonecode70do-LED modular down light 1'x1' / 34 -22wattEach4356.564356.564.0FalseNoneNoneFalseNoneFalse17426.240
3763723141583Nonecode71do-LED modular down light 10-12wattEach1497.421497.4212.0FalseNoneNoneFalseNoneFalse17969.040
3763724141583Nonecode72Supply of LED Streetlight luminaire with pressure die castaluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical ompartment & impact resistance of complete luminaire IK08. Power Factor 0.9 withmains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598,LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned 70wattEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3763725141583Nonecode73Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended 5 m - Top 70 mm and Bottom 130 mm diaEach11682.011682.01.0FalseNoneNoneFalseNoneFalse11682.00
3763726141583Nonecode74Using 2 m long 19mm 18 SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickelplatedEach672.6672.62.0FalseNoneNoneFalseNoneFalse1345.20
3763727141583Nonecode75Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 12/15 watts 230V LED lamp.Each1416.01416.08.0FalseNoneNoneFalseNoneFalse11328.00
3763728141583Nonecode76supplying and fixing metal fan box with round hookEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3763729141583Nonecode77Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / GirdersEach143.96143.9630.0FalseNoneNoneFalseNoneFalse4318.80
3763730141583Nonecode78Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiringusing suitable capacity wiresEach672.6672.64.0FalseNoneNoneFalseNoneFalse2690.40
3763731141583Nonecode79Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3763732141583Nonecode80Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7812.0FalseNoneNoneFalseNoneFalse2421.360
3763733141583Nonecode81Extra length of GI pipe of class B 19mm dia for down rodMtr232.46232.4612.0FalseNoneNoneFalseNoneFalse2789.520
3763734141583Nonecode82Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC SupplyEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3763735141583Nonecode83Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wireEach580.56580.564.0FalseNoneNoneFalseNoneFalse2322.240
3763736141583Nonecode84EB - METER BOARD :- Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.-600mm x 600mm x 170mm.Each17133.617133.62.0FalseNoneNoneFalseNoneFalse34267.20
3763737141583Nonecode85EARTHING:-Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo4141.84141.83.0FalseNoneNoneFalseNoneFalse12425.40
3763738141583Nonecode86Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and uitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No5022.085022.082.0FalseNoneNoneFalseNoneFalse10044.160
3763739141583Nonecode87Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.- 50mm diaMtr531.0531.015.0FalseNoneNoneFalseNoneFalse7965.00
3763740141583Nonecode88Supplying & Fixing of 250W/400W High Pressure Sodium Vapour tubular Lamp with Xenon filled gas with luminous efficiency of greater than 140 lumen/W or initial lumens of greater than 55000 lumens & avg rated life greater than26000 hrs & minimum starting temperature of(-)40 deg C& Hot restrike time 60 Sec with CCT 2000K Operating voltage range from 180V to 265V, 50Hz AC power SupplyNo2093.322093.323.0FalseNoneNoneFalseNoneFalse6279.960
3763741141583Nonecode89Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.Sq CM0.590.5915000.0FalseNoneNoneFalseNoneFalse8850.00
3763742141583Nonecode90Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440 VAC 50Hz 12/24D.CEach607.7607.78.0FalseNoneNoneFalseNoneFalse4861.60
3763743141583Nonecode91Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.Each473.18473.184.0FalseNoneNoneFalseNoneFalse1892.720
3763744141583Nonecode92Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.71.0FalseNoneNoneFalseNoneFalse10991.70
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17235303630000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17235303630000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17235303630000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17235303630000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17235303630000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17235303800000NoneNoneELIGIBILITYThe Contractor should quote the item wise rates Inclusive of GST.None
17235303970000NoneNoneELIGIBILITYThe bidder shall deliver to the Chief Engineer (Ele.), O&M Zone, BESCOM, Chitradurga an additional security for unbalanced tenders (If the bidder quoted his lesser rates compared to the amount put to tender) in accordance with Clause 25.5 of ITT & Clause 44 of the conditions of contract for all works (BG/FDR in favour of the Chief Engineer(Ele.), O&M Zone, BESCOM, Chitradurga payable at Chitradurga).None
17235304120000NoneNoneELIGIBILITYWithin 20 days of the receipt of the letter of Intent, the successful bidder shall deliver to the Chief Engineer(Ele.), O&M Zone, BESCOM, Chitradurga a security deposit for an amount equivalent to 5% of the contract price (BG/FDR in favour of the Chief Engineer(Ele.), O&M Zone, BESCOM, Chitradurga payable at Chitradurga).None
17235304400000NoneNoneELIGIBILITYFor more details, refer attached NIT.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneThe bidder shall upload the work done certificate for having executed one similar nature/building work of value not less than 50% of amount put to tender i.e., Rs. 25.00 lakhs and completed satisfactorily as a prime contractor within stipulated time period in the past 5 years (i.e., 2019-20 to 2023-24). Work done certificate shall be duly signed by the officer not below the rank of Executive Engineer or equivalentPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneBidders who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The bidder shall upload his tender capacity calculation in his letter head along with date and signature with Seal.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tender capacity calculation sheet
NoneNoneNoneNoneThe annual turnover of the bidder shall not be less than the amount put to tender i.e., Rs.50.00 lakhs per year in any TWO of the previous 5 financial years (i.e., 2019-20 to 2023-24). Turnover certificate issued by Chartered accountant shall be uploaded. In support of this, the balance sheets and profit loss statements issued by a Chartered Accountant for the any two of the previous 5 financial years shall be scanned and uploaded. (i.e.2019-20 to 2023-24) (Registered Chartered Accountant PIN must be mentioned)For the certificates, UDIN is mandatory.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneavailability of the credit facility issued by any Indian Nationalized Bank/Scheduled Bank (enjoying credit facility) shall not be less than 30% of the amount put to the tender. The credit facility certificate after this notification date (Bankers certificate as per uploaded format) issued by any Nationalized Bank/Scheduled Indian Bank addressed to the Chief Engineer(Ele), CTAZ, BESCOM, Opp. RTO Office, Turuvanur Road, Chitradurga 577 501 shall be scanned and uploaded in original. (Rs.15.00 lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five years audited by CA.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Balance sheets and PL statements audited by CA
NoneNoneNoneNoneThe bidder shall be a Registered KPWD Civil contractor of Class-IV and above. The valid License in original shall be scanned and uploaded.OthersKPWD License
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneThe bidder shall possess valid GST registration number. The original GST Certificate shall be scanned and uploaded.OthersGST registration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneBidder shall upload the self-declaration affidavit as per the enclosed format on the stamp paper of value not less than Rs. 100/- duly notarizedOthersself declaration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- self declaration copy
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Bankers CertificateTrueTechnical Bid
Self Declaration CertificateTrueTechnical Bid
KPWD LicenceTrueTechnical Bid
Tender Capacity Calculation SheetTrueTechnical Bid
Workdone certificateTrueTechnical Bid
Balance sheets and PL statements issued by CATrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone