1723544030000 | 0 | None | None | Buildings | Construction of Block-II (4 tenements) residential quarters for Officers at BESCOM colony, Hiriyur. | 15298276.34 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3767967 | 141896 | None | code01 | Providing Soil investigation of the proposed for construction, preparation and submission of structural design details, Electrical layout, plumbing and sanitary system and all other detail drawings required for successful completion of the project. | Job | 88500.0 | 88500.0 | 1.0 | False | None | None | False | None | False | 88500.0 | 0 | 3767968 | 141896 | None | code02 | Clearing and grubbing road land including uprooting rankvegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer. | Sqm | 4.78 | 4.78 | 500.0 | False | None | None | False | None | False | 2390.0 | 0 | 3767969 | 141896 | None | code03 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including co.st of labour, tools, usage & other appurtenances required to complete the work In all kinds of soil upto 300 mm depth | Cum | 110.6 | 110.6 | 325.0 | False | None | None | False | None | False | 35945.0 | 0 | 3767970 | 141896 | None | code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work -In all kinds of soils Depth upto 3 m | Cum | 123.97 | 123.97 | 250.0 | False | None | None | False | None | False | 30992.5 | 0 | 3767971 | 141896 | None | code05 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. Lindane 20% E.C. 3.19 m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 143.42 | 143.42 | 350.0 | False | None | None | False | None | False | 50197.0 | 0 | 3767972 | 141896 | None | code06 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 576.1 | 576.1 | 295.0 | False | None | None | False | None | False | 169949.5 | 0 | 3767973 | 141896 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M7.5) Using 40 mm nominal size graded crushed coarse aggregates) | Cum | 6884.03 | 6884.03 | 67.5 | False | None | None | False | None | False | 464672.025 | 0 | 3767974 | 141896 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7587.74 | 7587.74 | 9.0 | False | None | None | False | None | False | 68289.66 | 0 | 3767975 | 141896 | None | code09 | Additional lift charges for First floor (for Cill and screed concrete) | Cum | 7663.62 | 7663.62 | 30.0 | False | None | None | False | None | False | 229908.6 | 0 | 3767976 | 141896 | None | code10 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-FOOTING M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including formwork charges for Footing etc.., Complete including with all lead , lift & asper the directions of Engineer In Charge of the work. | Cum | 8316.84 | 8316.84 | 30.0 | False | None | None | False | None | False | 249505.2 | 0 | 3767977 | 141896 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do columns Ground Floor (Including formwork charges) (50% on concrete rate considered-formwork charges) | Cum | 12475.47 | 12475.47 | 15.0 | False | None | None | False | None | False | 187132.05 | 0 | 3767978 | 141896 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do columns Ground Floor (Including formwork charges) (70% on concrete rate considered-formwork charges) | Cum | 14138.87 | 14138.87 | 14.0 | False | None | None | False | None | False | 197944.18 | 0 | 3767979 | 141896 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do columns Ground Floor (Including formwork charges) (60% on concrete rate considered-formwork charges) | Cum | 13307.17 | 13307.17 | 18.0 | False | None | None | False | None | False | 239529.06 | 0 | 3767980 | 141896 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do columns Ground Floor (Including formwork charges) (50% on concrete rate considered-formwork charges) | Cum | 12475.47 | 12475.47 | 44.5 | False | None | None | False | None | False | 555158.415 | 0 | 3767981 | 141896 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates First Floor Columns (Including formwork charges) (70% on concrete rate considered-formwork charges) | Cum | 14280.26 | 14280.26 | 13.0 | False | None | None | False | None | False | 185643.38 | 0 | 3767982 | 141896 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates First Floor Beams (Including formwork charges) (60% on concrete rate considered-formwork charges) | Cum | 13440.24 | 13440.24 | 18.0 | False | None | None | False | None | False | 241924.32 | 0 | 3767983 | 141896 | None | code17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates First Floor Slab (Including formwork charges) (50% on concrete rate considered-formwork charges) | Cum | 12600.23 | 12600.23 | 45.0 | False | None | None | False | None | False | 567010.35 | 0 | 3767984 | 141896 | None | code18 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates Second Floor columns (Including formwork charges) (70% on concrete rate considered-formwork charges) | Cum | 14423.06 | 14423.06 | 2.0 | False | None | None | False | None | False | 28846.12 | 0 | 3767985 | 141896 | None | code19 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates First Floor Beams (Including formwork charges) (60% on concrete rate considered-formwork charges) ) Additional lift charges for second floor Lintel. | Cum | 13573.31 | 13573.31 | 2.5 | False | None | None | False | None | False | 33933.275 | 0 | 3767986 | 141896 | None | code20 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates Second Floor Slab (Including formwork charges) (50% on concrete rate considered-formwork charges) Additional lift charges for second floor. | Cum | 12724.98 | 12724.98 | 6.5 | False | None | None | False | None | False | 82712.37 | 0 | 3767987 | 141896 | None | code21 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings Ground floor | Tonne | 108726.04 | 108726.04 | 12.0 | False | None | None | False | None | False | 1304712.48 | 0 | 3767988 | 141896 | None | code22 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings First floor | Tonne | 109813.3 | 109813.3 | 8.0 | False | None | None | False | None | False | 878506.4 | 0 | 3767989 | 141896 | None | code23 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do Chajja Ground Floor(Including formwork charges) | Cum | 12059.62 | 12059.62 | 2.0 | False | None | None | False | None | False | 24119.24 | 0 | 3767990 | 141896 | None | code24 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates Chajja First Floor (Including formwork charges) | Cum | 12180.22 | 12180.22 | 2.0 | False | None | None | False | None | False | 24360.44 | 0 | 3767991 | 141896 | None | code25 | Providing brickwork with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. do-Ground Floor | Cum | 9991.8 | 9991.8 | 94.0 | False | None | None | False | None | False | 939229.2 | 0 | 3767992 | 141896 | None | code26 | do- for First floor (for BBM) | Cum | 10091.72 | 10091.72 | 70.0 | False | None | None | False | None | False | 706420.4 | 0 | 3767993 | 141896 | None | code27 | do-for Second floor (for BBM) | Cum | 10191.64 | 10191.64 | 20.0 | False | None | None | False | None | False | 203832.8 | 0 | 3767994 | 141896 | None | code28 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work) | Sqm | 1255.51 | 1255.51 | 51.0 | False | None | None | False | None | False | 64031.01 | 0 | 3767995 | 141896 | None | code29 | do-First floor for BBM Partion wall | Sqm | 1268.06 | 1268.06 | 65.0 | False | None | None | False | None | False | 82423.9 | 0 | 3767996 | 141896 | None | code30 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I)2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1592.17 | 1592.17 | 25.0 | False | None | None | False | None | False | 39804.25 | 0 | 3767997 | 141896 | None | code31 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications | Cum | 2451.46 | 2451.46 | 10.5 | False | None | None | False | None | False | 25740.33 | 0 | 3767998 | 141896 | None | code32 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge etc., complete with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc.B34 | Sqm | 992.98 | 992.98 | 15.0 | False | None | None | False | None | False | 14894.7 | 0 | 3767999 | 141896 | None | code33 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 204.19 | 204.19 | 2120.0 | False | None | None | False | None | False | 432882.8 | 0 | 3768000 | 141896 | None | code34 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications | Cum | 167815.14 | 167815.14 | 1.95 | False | None | None | False | None | False | 327239.523 | 0 | 3768001 | 141896 | None | code35 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.30 mm thick one side teak and one side commercial | Sqm | 4245.39 | 4245.39 | 25.0 | False | None | None | False | None | False | 106134.75 | 0 | 3768002 | 141896 | None | code36 | Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 7474.71 | 7474.71 | 15.0 | False | None | None | False | None | False | 112120.65 | 0 | 3768003 | 141896 | None | code37 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete | No | 1278.6 | 1278.6 | 4.0 | False | None | None | False | None | False | 5114.4 | 0 | 3768004 | 141896 | None | code38 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | No | 288.05 | 288.05 | 70.0 | False | None | None | False | None | False | 20163.5 | 0 | 3768005 | 141896 | None | code39 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10mm No | No | 528.7 | 528.7 | 70.0 | False | None | None | False | None | False | 37009.0 | 0 | 3768006 | 141896 | None | code40 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type) | No | 334.24 | 334.24 | 70.0 | False | None | None | False | None | False | 23396.8 | 0 | 3768007 | 141896 | None | code41 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | No | 1234.85 | 1234.85 | 36.0 | False | None | None | False | None | False | 44454.6 | 0 | 3768008 | 141896 | None | code42 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbent single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness | Sqm | 4911.43 | 4911.43 | 19.0 | False | None | None | False | None | False | 93317.17 | 0 | 3768009 | 141896 | None | code43 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6551.01 | 6551.01 | 52.0 | False | None | None | False | None | False | 340652.52 | 0 | 3768010 | 141896 | None | code44 | Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS: 15622 (thickness to be specified by the manufacturer), ofapproved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer- in-Charge, in skirting,risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per m2, including pointing in white cement mixed with pigmentof matching shade complete. | Sqm | 1344.23 | 1344.23 | 240.0 | False | None | None | False | None | False | 322615.2 | 0 | 3768011 | 141896 | None | code45 | do- for First floor | Sqm | 1357.67 | 1357.67 | 240.0 | False | None | None | False | None | False | 325840.8 | 0 | 3768012 | 141896 | None | code46 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 1080.49 | 1080.49 | 63.0 | False | None | None | False | None | False | 68070.87 | 0 | 3768013 | 141896 | None | code47 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm | Sqm | 1428.1 | 1428.1 | 169.0 | False | None | None | False | None | False | 241348.9 | 0 | 3768014 | 141896 | None | code48 | do- for First floor | Sqm | 1442.38 | 1442.38 | 169.0 | False | None | None | False | None | False | 243762.22 | 0 | 3768015 | 141896 | None | code49 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Ground Floor | Sqm | 6475.65 | 6475.65 | 45.0 | False | None | None | False | None | False | 291404.25 | 0 | 3768016 | 141896 | None | code50 | do-for First floor | Sqm | 6540.41 | 6540.41 | 40.0 | False | None | None | False | None | False | 261616.4 | 0 | 3768017 | 141896 | None | code51 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. | Sqm | 1132.75 | 1132.75 | 25.0 | False | None | None | False | None | False | 28318.75 | 0 | 3768018 | 141896 | None | code52 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 358.54 | 358.54 | 240.0 | False | None | None | False | None | False | 86049.6 | 0 | 3768019 | 141896 | None | code53 | do- for First floor | Sqm | 362.13 | 362.13 | 240.0 | False | None | None | False | None | False | 86911.2 | 0 | 3768020 | 141896 | None | code54 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.73 | 404.73 | 1500.0 | False | None | None | False | None | False | 607095.0 | 0 | 3768021 | 141896 | None | code55 | do- for First floor | Sqm | 408.78 | 408.78 | 1300.0 | False | None | None | False | None | False | 531414.0 | 0 | 3768022 | 141896 | None | code56 | Providing 12 mm cement plaster (ceiling surface) with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.do-Ground Floor | Sqm | 309.93 | 309.93 | 230.0 | False | None | None | False | None | False | 71283.9 | 0 | 3768023 | 141896 | None | code57 | do- for First floor | Sqm | 313.03 | 313.03 | 300.0 | False | None | None | False | None | False | 93909.0 | 0 | 3768024 | 141896 | None | code58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. do-Ground Floor | Sqm | 121.54 | 121.54 | 900.0 | False | None | None | False | None | False | 109386.0 | 0 | 3768025 | 141896 | None | code59 | do- for First floor | Sqm | 122.76 | 122.76 | 900.0 | False | None | None | False | None | False | 110484.0 | 0 | 3768026 | 141896 | None | code60 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. Ground Floor | Sqm | 64.42 | 64.42 | 900.0 | False | None | None | False | None | False | 57978.0 | 0 | 3768027 | 141896 | None | code61 | do- for First floor | Sqm | 65.06 | 65.06 | 900.0 | False | None | None | False | None | False | 58554.0 | 0 | 3768028 | 141896 | None | code62 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work(Two coats applied @ 1.43 litre/ 10 m2. Over and including priming coat of exterior primer applied @ 0.90 litre/10 m2 with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.do-Ground Floor | Sqm | 189.6 | 189.6 | 900.0 | False | None | None | False | None | False | 170640.0 | 0 | 3768029 | 141896 | None | code63 | do- for First floor | Sqm | 191.5 | 191.5 | 900.0 | False | None | None | False | None | False | 172350.0 | 0 | 3768030 | 141896 | None | code64 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m2 over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. do-Ground Floor | Sqm | 211.48 | 211.48 | 600.0 | False | None | None | False | None | False | 126888.0 | 0 | 3768031 | 141896 | None | code65 | do- for First floor | Sqm | 213.59 | 213.59 | 400.0 | False | None | None | False | None | False | 85436.0 | 0 | 3768032 | 141896 | None | code66 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 202.97 | 202.97 | 105.0 | False | None | None | False | None | False | 21311.85 | 0 | 3768033 | 141896 | None | code67 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | Sqm | 972.32 | 972.32 | 70.0 | False | None | None | False | None | False | 68062.4 | 0 | 3768034 | 141896 | None | code68 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 6628.79 | 6628.79 | 9.0 | False | None | None | False | None | False | 59659.11 | 0 | 3768035 | 141896 | None | code69 | Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete.Heavy Duty | Each | 3116.29 | 3116.29 | 10.0 | False | None | None | False | None | False | 31162.9 | 0 | 3768036 | 141896 | None | code70 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm withintegral type foot rests | Each | 5936.01 | 5936.01 | 4.0 | False | None | None | False | None | False | 23744.04 | 0 | 3768037 | 141896 | None | code71 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid | Each | 7264.45 | 7264.45 | 4.0 | False | None | None | False | None | False | 29057.8 | 0 | 3768038 | 141896 | None | code72 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Each | 5008.66 | 5008.66 | 4.0 | False | None | None | False | None | False | 20034.64 | 0 | 3768039 | 141896 | None | code73 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | No | 267.39 | 267.39 | 16.0 | False | None | None | False | None | False | 4278.24 | 0 | 3768040 | 141896 | None | code74 | Providing and fixing brass bib cock of approved quality :20 mm nominal bore | No | 370.7 | 370.7 | 40.0 | False | None | None | False | None | False | 14828.0 | 0 | 3768041 | 141896 | None | code75 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore | No | 370.7 | 370.7 | 20.0 | False | None | None | False | None | False | 7414.0 | 0 | 3768042 | 141896 | None | code76 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x 250 mm | Each | 3623.11 | 3623.11 | 4.0 | False | None | None | False | None | False | 14492.44 | 0 | 3768043 | 141896 | None | code77 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. | Sqm | 5200.7 | 5200.7 | 50.0 | False | None | None | False | None | False | 260035.0 | 0 | 3768044 | 141896 | None | code78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.on wall 20 mm nominal dia Pipes | Mtr | 460.64 | 460.64 | 70.0 | False | None | None | False | None | False | 32244.8 | 0 | 3768045 | 141896 | None | code79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work Exposed on wall. Internal work Exposed on wall 25 mm nominal dia | Mtr | 386.5 | 386.5 | 230.0 | False | None | None | False | None | False | 88895.0 | 0 | 3768046 | 141896 | None | code80 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)25 mm nominal bore | No | 667.25 | 667.25 | 4.0 | False | None | None | False | None | False | 2669.0 | 0 | 3768047 | 141896 | None | code81 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 499.53 | 499.53 | 170.0 | False | None | None | False | None | False | 84920.1 | 0 | 3768048 | 141896 | None | code82 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia6 kg/sqcm & class 3 | Mtr | 785.15 | 785.15 | 50.0 | False | None | None | False | None | False | 39257.5 | 0 | 3768049 | 141896 | None | code83 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Kgs | 686.7 | 686.7 | 250.0 | False | None | None | False | None | False | 171675.0 | 0 | 3768050 | 141896 | None | code84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. | Ltr | 10.94 | 10.94 | 4000.0 | False | None | None | False | None | False | 43760.0 | 0 | 3768051 | 141896 | None | code85 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest 2.00 HP/1.5KW 10 STG | Each | 20653.29 | 20653.29 | 4.0 | False | None | None | False | None | False | 82613.16 | 0 | 3768052 | 141896 | None | code86 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 5442.56 | 5442.56 | 2.0 | False | None | None | False | None | False | 10885.12 | 0 | 3768053 | 141896 | None | code87 | Concealed Conduit System -Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary-19/20mm dia 2mm thick. | Mtr | 77.88 | 77.88 | 750.0 | False | None | None | False | None | False | 58410.0 | 0 | 3768054 | 141896 | None | code88 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit GI pipe and plastering, finishing upto wall surface completeupto 50 mm conduit in brick wall | Mtr | 34.22 | 34.22 | 300.0 | False | None | None | False | None | False | 10266.0 | 0 | 3768055 | 141896 | None | code89 | Supplying heavy gauge PVC Conduit Pipedia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 80.24 | 80.24 | 300.0 | False | None | None | False | None | False | 24072.0 | 0 | 3768056 | 141896 | None | code90 | do-Short point upto 3Mtr from tapping point to out let via switch | Point | 336.3 | 336.3 | 32.0 | False | None | None | False | None | False | 10761.6 | 0 | 3768057 | 141896 | None | code91 | do-Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch. | Point | 464.92 | 464.92 | 60.0 | False | None | None | False | None | False | 27895.2 | 0 | 3768058 | 141896 | None | code92 | do-Long point above 6Mtr upto 10Mtr from tapping point to out let via switch. | Point | 672.6 | 672.6 | 30.0 | False | None | None | False | None | False | 20178.0 | 0 | 3768059 | 141896 | None | code93 | Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 2010 confirming to latest amemndments 1.5 Sqmm. ( Lighting & Power Circuit Earthing). | Mtr | 30.68 | 30.68 | 540.0 | False | None | None | False | None | False | 16567.2 | 0 | 3768060 | 141896 | None | code94 | do- 2.5 Sqmm | Mtr | 49.56 | 49.56 | 750.0 | False | None | None | False | None | False | 37170.0 | 0 | 3768061 | 141896 | None | code95 | do- 4.00 Sqmm | Mtr | 74.34 | 74.34 | 500.0 | False | None | None | False | None | False | 37170.0 | 0 | 3768062 | 141896 | None | code96 | supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone c.c wall 3 way | Each | 187.62 | 187.62 | 40.0 | False | None | None | False | None | False | 7504.8 | 0 | 3768063 | 141896 | None | code97 | do- 4-5 way. | Each | 208.86 | 208.86 | 30.0 | False | None | None | False | None | False | 6265.8 | 0 | 3768064 | 141896 | None | code98 | do-6way | Each | 261.96 | 261.96 | 30.0 | False | None | None | False | None | False | 7858.8 | 0 | 3768065 | 141896 | None | code99 | do- 8way | Each | 307.98 | 307.98 | 20.0 | False | None | None | False | None | False | 6159.6 | 0 | 3768066 | 141896 | None | code100 | do- 10-12way | Each | 376.42 | 376.42 | 20.0 | False | None | None | False | None | False | 7528.4 | 0 | 3768067 | 141896 | None | code101 | do- 1-3 module | Each | 189.98 | 189.98 | 10.0 | False | None | None | False | None | False | 1899.8 | 0 | 3768068 | 141896 | None | code102 | do- 4 module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3768069 | 141896 | None | code103 | do- 6 module | Each | 276.12 | 276.12 | 15.0 | False | None | None | False | None | False | 4141.8 | 0 | 3768070 | 141896 | None | code104 | do- 8 module | Each | 335.12 | 335.12 | 15.0 | False | None | None | False | None | False | 5026.8 | 0 | 3768071 | 141896 | None | code105 | do- 10-12 module | Each | 405.92 | 405.92 | 10.0 | False | None | None | False | None | False | 4059.2 | 0 | 3768072 | 141896 | None | code106 | Supplying and fixing superior quality of modular switch and connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. 6Amps one way Switch | Each | 120.36 | 120.36 | 80.0 | False | None | None | False | None | False | 9628.8 | 0 | 3768073 | 141896 | None | code107 | do-6Amps two way Switch | Each | 195.88 | 195.88 | 20.0 | False | None | None | False | None | False | 3917.6 | 0 | 3768074 | 141896 | None | code108 | do- 6Amps 3 way socket | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3768075 | 141896 | None | code109 | do- Stepped fan regulator | Each | 421.26 | 421.26 | 12.0 | False | None | None | False | None | False | 5055.12 | 0 | 3768076 | 141896 | None | code110 | do- 6Amps Bell Push | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3768077 | 141896 | None | code111 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote | Each | 290.28 | 290.28 | 4.0 | False | None | None | False | None | False | 1161.12 | 0 | 3768078 | 141896 | None | code112 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned Copper cable. 2 pair | Mtr | 80.0 | 80.0 | 70.0 | False | None | None | False | None | False | 5600.0 | 0 | 3768079 | 141896 | None | code113 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. | Mtr | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3768080 | 141896 | None | code114 | Supplying and fixing of 4 feet - PVC Batten with integrated LED tube 20/22.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-4 feet LED Fitting. | Each | 814.2 | 814.2 | 18.0 | False | None | None | False | None | False | 14655.6 | 0 | 3768081 | 141896 | None | code115 | Supplying & fixing of retrofit type LED bulb 12W,65000k with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.(Cost including with necessary base fixing pedent type holder.) | Each | 317.42 | 317.42 | 25.0 | False | None | None | False | None | False | 7935.5 | 0 | 3768082 | 141896 | None | code116 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/-10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 12.0 | False | None | None | False | None | False | 37906.32 | 0 | 3768083 | 141896 | None | code117 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 371.7 | 371.7 | 12.0 | False | None | None | False | None | False | 4460.4 | 0 | 3768084 | 141896 | None | code118 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.-12" Sweep (300mm) | Each | 3102.22 | 3102.22 | 4.0 | False | None | None | False | None | False | 12408.88 | 0 | 3768085 | 141896 | None | code119 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 834.26 | 834.26 | 4.0 | False | None | None | False | None | False | 3337.04 | 0 | 3768086 | 141896 | None | code120 | Supplying and fixing of round or oblong type bulk head fitting with glass cover | Each | 1062.0 | 1062.0 | 1.0 | False | None | None | False | None | False | 1062.0 | 0 | 3768087 | 141896 | None | code121 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32A DP | Each | 872.02 | 872.02 | 5.0 | False | None | None | False | None | False | 4360.1 | 0 | 3768088 | 141896 | None | code122 | CONSUMER CONTROL TPN DB Supplying and fixing regular MCB distribution boards on wall/Wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.6 WAY TP & N Double Door DB. | Each | 5829.2 | 5829.2 | 4.0 | False | None | None | False | None | False | 23316.8 | 0 | 3768089 | 141896 | None | code123 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.-63A | Each | 473.18 | 473.18 | 7.0 | False | None | None | False | None | False | 3312.26 | 0 | 3768090 | 141896 | None | code124 | EARTHING Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Each | 4141.8 | 4141.8 | 5.0 | False | None | None | False | None | False | 20709.0 | 0 |
|