tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1723543771000 | 0 | None | None | Buildings | CIVIL WORK FOR Construction of Two Classrooms at Govt Pre University College in Khanapur Taluka (DD No 0251) | 3849633.55 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3767847 | 141890 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 101.92 | 101.92 | 174.7192 | False | None | None | False | None | False | 17807.380864 | 0 | 3767848 | 141890 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m, with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 114.24 | 114.24 | 120.64 | False | None | None | False | None | False | 13781.9136 | 0 | 3767849 | 141890 | None | code03 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 1122.24 | 1122.24 | 12.8 | False | None | None | False | None | False | 14364.672 | 0 | 3767850 | 141890 | None | code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. 2.1.1 Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates, with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 5978.56 | 5978.56 | 5.481 | False | None | None | False | None | False | 32768.48736 | 0 | 3767851 | 141890 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork is Excluded)-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 15 /I.No.2.2.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7041.44 | 7041.44 | 18.8892 | False | None | None | False | None | False | 133007.168448 | 0 | 3767852 | 141890 | None | code06 | Formwork for footings @3%(V1/Addendum I/Pg.no111) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 211.24 | 211.24 | 18.8892 | False | None | None | False | None | False | 3990.154608 | 0 | 3767853 | 141890 | None | code07 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork is Excluded)M20 Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 16/ I.No.2.4.2) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7081.76 | 7081.76 | 3.887 | False | None | None | False | None | False | 27526.80112 | 0 | 3767854 | 141890 | None | code08 | Formwork for column @ 70%(V1/Addendum I/Pg.no111) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 4957.23 | 4957.23 | 3.887 | False | None | None | False | None | False | 19268.75301 | 0 | 3767855 | 141890 | None | code09 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(PWD CSR V-1 2023-24 / P.No. 7/ I.No.1.9) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 297.92 | 297.92 | 66.088 | False | None | None | False | None | False | 19688.93696 | 0 | 3767856 | 141890 | None | code10 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork is Excluded)M20 Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 16/ I.No.2.4.2) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7081.76 | 7081.76 | 8.6691 | False | None | None | False | None | False | 61392.485616 | 0 | 3767857 | 141890 | None | code11 | Formwork for plinth beams@ 50%(V1/Addendum I/Pg.no111) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 3540.88 | 3540.88 | 8.6691 | False | None | None | False | None | False | 30696.242808 | 0 | 3767858 | 141890 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 16/ I.No.2.5.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7425.6 | 7425.6 | 6.585 | False | None | None | False | None | False | 48897.576 | 0 | 3767859 | 141890 | None | code13 | Formwork for column @ 70%(V1/Addendum I/Pg.no111) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., comple | Cum | 5197.92 | 5197.92 | 6.585 | False | None | None | False | None | False | 34228.3032 | 0 | 3767860 | 141890 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 16/ I.No.2.5.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7425.6 | 7425.6 | 14.8122 | False | None | None | False | None | False | 109989.47232 | 0 | 3767861 | 141890 | None | code15 | Formwark for Lintels, Beams @ 60%(V1/Addendum I/Pg.no112) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 4455.36 | 4455.36 | 14.8122 | False | None | None | False | None | False | 65993.683392 | 0 | 3767862 | 141890 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 16/ I.No.2.5.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7425.6 | 7425.6 | 26.2078 | False | None | None | False | None | False | 194608.63968 | 0 | 3767863 | 141890 | None | code17 | Formwark for Roof Slab @ 50%(V1/Addendum I/Pg.no111) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 3712.8 | 3712.8 | 26.2078 | False | None | None | False | None | False | 97304.31984 | 0 | 3767864 | 141890 | None | code18 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 16/ I.No.2.5.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7425.6 | 7425.6 | 0.3543 | False | None | None | False | None | False | 2630.89008 | 0 | 3767865 | 141890 | None | code19 | Formwark for chajja@ 45%(V1/Addendum I/Pg.no111) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 3341.52 | 3341.52 | 0.3543 | False | None | None | False | None | False | 1183.900536 | 0 | 3767866 | 141890 | None | code20 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(PWD CSR V-1 2023-24 / P.No. 7 I.No.1.11) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 484.96 | 484.96 | 162.9714 | False | None | None | False | None | False | 79034.610144 | 0 | 3767867 | 141890 | None | code21 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge(PWD CSR V-2 2023-24 / P.No. -175/ I.No.-17.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 1122.24 | 1122.24 | 35.8434 | False | None | None | False | None | False | 40224.897216 | 0 | 3767868 | 141890 | None | code22 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10)Using 40 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 15 I.No.2.1.3) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6707.68 | 6707.68 | 23.764 | False | None | None | False | None | False | 159401.30752 | 0 | 3767869 | 141890 | None | code23 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(PWD SR V-2 2023-24 / P.No. 14 I.No.6.8) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 8925.28 | 8925.28 | 57.142 | False | None | None | False | None | False | 510008.34976 | 0 | 3767870 | 141890 | None | code24 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(PWD SR V-1 2023-24 / P.No. 18/ I.No.2.11) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Tonne | 100191.84 | 100191.84 | 7.8903 | False | None | None | False | None | False | 790543.675152 | 0 | 3767871 | 141890 | None | code25 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 41 I.No.8.1.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 285.6 | 285.6 | 374.87 | False | None | None | False | None | False | 107062.872 | 0 | 3767872 | 141890 | None | code26 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(PWD SR V-2 2023-24 / P.No. 42 I.No.8.8) | Sqm | 415.52 | 415.52 | 263.0526 | False | None | None | False | None | False | 109303.616352 | 0 | 3767873 | 141890 | None | code27 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent : (PWD SR V-2 2023-24 / P.No. 60/ I.No.9.12.2) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 3194.24 | 3194.24 | 162.8681 | False | None | None | False | None | False | 520239.799744 | 0 | 3767874 | 141890 | None | code28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(PWD SR V-2 2023-24 / P.No. 50 I.No.8.51) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 112.0 | 112.0 | 374.87 | False | None | None | False | None | False | 41985.44 | 0 | 3767875 | 141890 | None | code29 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(PWD SR V-2 2023-24 / P.No. 109/ I.No.12.87) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 7337.12 | 7337.12 | 23.586 | False | None | None | False | None | False | 173053.31232 | 0 | 3767876 | 141890 | None | code30 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(PWD SR V-2 2023-24 / P.No. 86/ I.No.11.34A) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 188.16 | 188.16 | 495.306 | False | None | None | False | None | False | 93196.77696 | 0 | 3767877 | 141890 | None | code31 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two coats) over and including water thinnable priming coat with cement primer after
thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 45 I.No.8.25) | Sqm | 153.44 | 153.44 | 374.87 | False | None | None | False | None | False | 57520.0528 | 0 | 3767878 | 141890 | None | code32 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 45 I.No.8.27) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 59.36 | 59.36 | 263.0526 | False | None | None | False | None | False | 15614.802336 | 0 | 3767879 | 141890 | None | code33 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 45 I.No.8.28) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 99.68 | 99.68 | 263.0526 | False | None | None | False | None | False | 26221.083168 | 0 | 3767880 | 141890 | None | code34 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications..(PWD SR V-2 2023-24 / P.No. 100 I.No.12.12) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 139106.24 | 139106.24 | 0.3168 | False | None | None | False | None | False | 44068.856832 | 0 | 3767881 | 141890 | None | code35 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )(PWD SR V-2 2023-24 / P.No. 100 I.No.12.15) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 8337.28 | 8337.28 | 12.6 | False | None | None | False | None | False | 105049.728 | 0 | 3767882 | 141890 | None | code36 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 47 I.No.8.33.3) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 155.68 | 155.68 | 23.586 | False | None | None | False | None | False | 3671.86848 | 0 | 3767883 | 141890 | None | code37 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 46 I.No.8.33.2) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 154.56 | 154.56 | 12.6 | False | None | None | False | None | False | 1947.456 | 0 | 3767884 | 141890 | None | code38 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.(PWD SR V-2 2023-24 / P.No. 84/ I.No.11.26.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 154.56 | 154.56 | 239.4 | False | None | None | False | None | False | 37001.664 | 0 | 3767885 | 141890 | None | code39 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete(PWD SR V-2 2023-24 / P.No. 105 I.No.12.62) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 265.44 | 265.44 | 4.0 | False | None | None | False | None | False | 1061.76 | 0 | 3767886 | 141890 | None | code40 | Brass Butt Hinges ( Heavy Type) 125x85x5.5mm 0.70kg with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 1792.0 | 1792.0 | 1.0 | False | None | None | False | None | False | 1792.0 | 0 | 3767887 | 141890 | None | code41 | Door Lock with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 389.76 | 389.76 | 4.0 | False | None | None | False | None | False | 1559.04 | 0 | 3767888 | 141890 | None | code42 | Oxidised mild Door Latch 250mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 67.2 | 67.2 | 4.0 | False | None | None | False | None | False | 268.8 | 0 | 3767889 | 141890 | None | code43 | PTMT Door Catcher with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 28.0 | 28.0 | 4.0 | False | None | None | False | None | False | 112.0 | 0 | 3767890 | 141890 | None | code44 | Screw 25mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 560.0 | 560.0 | 1.0 | False | None | None | False | None | False | 560.0 | 0 |
| 1723543771000 | 0 | None | None | Buildings | ELECTRICAL WORK FOR Construction of Two Classrooms at Govt Pre University College in Khanapur Taluka (DD No 0251) | 163984.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3767891 | 141891 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25mm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 39.2 | 39.2 | 200.0 | False | None | None | False | None | False | 7840.0 | 0 | 3767892 | 141891 | None | code02 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 4"x4"x3" ( 101x101x76mm) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 82.88 | 82.88 | 15.0 | False | None | None | False | None | False | 1243.2 | 0 | 3767893 | 141891 | None | code03 | I. Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Using class A Materialsb) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 441.28 | 441.28 | 15.0 | False | None | None | False | None | False | 6619.2 | 0 | 3767894 | 141891 | None | code04 | I. Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Using class A Materials c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 638.4 | 638.4 | 15.0 | False | None | None | False | None | False | 9576.0 | 0 | 3767895 | 141891 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 29.12 | 29.12 | 350.0 | False | None | None | False | None | False | 10192.0 | 0 | 3767896 | 141891 | None | code06 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 47.04 | 47.04 | 85.0 | False | None | None | False | None | False | 3998.4 | 0 | 3767897 | 141891 | None | code07 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 70.56 | 70.56 | 250.0 | False | None | None | False | None | False | 17640.0 | 0 | 3767898 | 141891 | None | code08 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 154.56 | 154.56 | 30.0 | False | None | None | False | None | False | 4636.8 | 0 | 3767899 | 141891 | None | code09 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 292.32 | 292.32 | 10.0 | False | None | None | False | None | False | 2923.2 | 0 | 3767900 | 141891 | None | code10 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 357.28 | 357.28 | 50.0 | False | None | None | False | None | False | 17864.0 | 0 | 3767901 | 141891 | None | code11 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 1 to 2 Module with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 153.44 | 153.44 | 10.0 | False | None | None | False | None | False | 1534.4 | 0 | 3767902 | 141891 | None | code12 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 8Moudule with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 318.08 | 318.08 | 5.0 | False | None | None | False | None | False | 1590.4 | 0 | 3767903 | 141891 | None | code13 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 10-12Moudule with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 385.28 | 385.28 | 8.0 | False | None | None | False | None | False | 3082.24 | 0 | 3767904 | 141891 | None | code14 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6Amps one way. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 114.24 | 114.24 | 50.0 | False | None | None | False | None | False | 5712.0 | 0 | 3767905 | 141891 | None | code15 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials Stepped Fan Regulator.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 399.84 | 399.84 | 10.0 | False | None | None | False | None | False | 3998.4 | 0 | 3767906 | 141891 | None | code16 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 16Amps one way switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 201.6 | 201.6 | 15.0 | False | None | None | False | None | False | 3024.0 | 0 | 3767907 | 141891 | None | code17 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 32Amps DP switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 365.12 | 365.12 | 10.0 | False | None | None | False | None | False | 3651.2 | 0 | 3767908 | 141891 | None | code18 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6/16Amps universal socket with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 264.32 | 264.32 | 12.0 | False | None | None | False | None | False | 3171.84 | 0 | 3767909 | 141891 | None | code19 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6Amps 3way socket. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 191.52 | 191.52 | 12.0 | False | None | None | False | None | False | 2298.24 | 0 | 3767910 | 141891 | None | code20 | Supplying of eet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI 80. Power Input: 2200-240V at 50/60Hz & Power factor 0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fitting 1 x 4 20/22 w Each LED light fitting 1 x 4 20/22 w Each
with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 772.8 | 772.8 | 25.0 | False | None | None | False | None | False | 19320.0 | 0 | 3767911 | 141891 | None | code21 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 269.92 | 269.92 | 5.0 | False | None | None | False | None | False | 1349.6 | 0 | 3767912 | 141891 | None | code22 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. a) 6-32Amps SP Group 'A' with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 464.8 | 464.8 | 1.0 | False | None | None | False | None | False | 464.8 | 0 | 3767913 | 141891 | None | code23 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 6-32 Amps DP Group 'A' with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 827.68 | 827.68 | 1.0 | False | None | None | False | None | False | 827.68 | 0 | 3767914 | 141891 | None | code24 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door II -a) 4Way TP &N with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 4522.56 | 4522.56 | 1.0 | False | None | None | False | None | False | 4522.56 | 0 | 3767915 | 141891 | None | code25 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg HESCOM SR with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 832.16 | 832.16 | 1.0 | False | None | None | False | None | False | 832.16 | 0 | 3767916 | 141891 | None | code26 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each HESCOM SR with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 757.12 | 757.12 | 1.0 | False | None | None | False | None | False | 757.12 | 0 | 3767917 | 141891 | None | code27 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag HESCOM SR with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Bag | 347.2 | 347.2 | 1.0 | False | None | None | False | None | False | 347.2 | 0 | 3767918 | 141891 | None | code28 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE HESCOM SR Hard Soil with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Per Pit | 3348.8 | 3348.8 | 1.0 | False | None | None | False | None | False | 3348.8 | 0 | 3767919 | 141891 | None | code29 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved. 48" Sweep (1200mm) Regular model with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 3342.08 | 3342.08 | 4.0 | False | None | None | False | None | False | 13368.32 | 0 | 3767920 | 141891 | None | code30 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 8"x6"1.5" with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 97.44 | 97.44 | 4.0 | False | None | None | False | None | False | 389.76 | 0 | 3767921 | 141891 | None | code31 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12"x12"2" with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 202.72 | 202.72 | 4.0 | False | None | None | False | None | False | 810.88 | 0 | 3767922 | 141891 | None | code32 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall / ceiling / Rafter / Girders with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 136.64 | 136.64 | 25.0 | False | None | None | False | None | False | 3416.0 | 0 | 3767923 | 141891 | None | code33 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 352.8 | 352.8 | 10.0 | False | None | None | False | None | False | 3528.0 | 0 | 3767924 | 141891 | None | code34 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 20mm, Point wiring using Copper wire with switch. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 21.28 | 21.28 | 5.0 | False | None | None | False | None | False | 106.4 | 0 |
| 1723543771000 | 0 | None | None | Buildings | FURNITURE WORK FOR Construction of Two Classrooms at Govt Pre University College in Khanapur Taluka (DD No 0251) | 170000.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3767925 | 141892 | None | code01 | Furniture As per Rate and Specication - Proceeding of the 15th Technical Advisory committee meeting held on 27.04.2016 at 10.30 am in the Rastriya Madyamika Shiksha Abhiyan meeting Hall at 4th Floor K.R Circle Bangalore- Details Specifiation Attached Seperate, with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | No | 85000.0 | 85000.0 | 2.0 | False | None | None | False | None | False | 170000.0 | 0 |
|
|
---|