createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722837284353
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1250.00
emd100000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose22-08-2024 16:00:00
tenderQueryClose19-08-2024 16:00:00
technicalBidOpen23-08-2024 16:30:00
publishedDate14-08-2024 12:29:42
publishedByPostEWHFWD_EE_EEOFF_DWD
publishedByUserKPE13493 - SURESH S N
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM M Kattimani
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08362955800
mobileNumber9740775411
tenderSupplierListNone
tenderSchedule
createdTs1722837284379
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT557
titleProposed Construction of Block Public Health Unit at Hunagund Taluk Level Hospital in Bagalkote District.
descriptionProposed Construction of Block Public Health Unit at Hunagund Taluk Level Hospital in Bagalkote District.
categoryWORKS
categoryTextWorks
ecv4995350.77
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3524
locationNameEWHFWD Executive Engineer Office Dharwad
provisionalAmount5000000.0
groupOverheadTotalNone
fileNumberAEE/HFWD/SD/VJP/HUNAGUNDA/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17228372840000NoneNoneBuildingsProposed Construction of Block Public Health Unit at Hunagund Taluk Level Hospital in Bagalkote District.-Civil Works4247040.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3689220135455None19.61V2Dismantling weather proof course and removing and conveying the debris to a distance to the ppropriate disposal area as per direction of Engineer-in-charge.Cum707.07707.0730.43FalseNoneNoneFalseNoneFalse21516.14010
3689221135455None19.3V2Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2978.052978.052.8FalseNoneNoneFalseNoneFalse8338.540
3689222135455None19.7.3V2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortarCum1263.151263.158.76FalseNoneNoneFalseNoneFalse11065.1940
3689223135455None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (for Column)Cum14280.2614280.2613.52FalseNoneNoneFalseNoneFalse193069.11520
3689224135455None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (for RCC BEAMS & LINTELS)Cum13440.2413440.2421.35FalseNoneNoneFalseNoneFalse286949.1240
3689225135455None2.5.2V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (for RCC SLAB)Cum12600.2312600.2340.58FalseNoneNoneFalseNoneFalse511317.33340
3689226135455None2.1.4V1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum11065.9711065.973.24FalseNoneNoneFalseNoneFalse35853.74280
3689227135455None15.4V3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/ EpoxyNo250.42250.4220.0FalseNoneNoneFalseNoneFalse5008.40
3689228135455None2.11aV1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne109813.3109813.36.75FalseNoneNoneFalseNoneFalse741239.7750
3689229135455None4.21SR18-19Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.m40.8940.8963.1FalseNoneNoneFalseNoneFalse2580.1590
3689230135455NoneMarket RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.Rmtr86.1486.1463.1FalseNoneNoneFalseNoneFalse5435.4340
3689231135455None6.2V2Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum9793.439793.4373.59FalseNoneNoneFalseNoneFalse720698.51370
3689232135455None6.15V2Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1268.061268.0618.0FalseNoneNoneFalseNoneFalse22825.080
3689233135455None12.13.1V2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum121300.75121300.750.23FalseNoneNoneFalseNoneFalse27899.17250
3689234135455None12.57.6V2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side CommercialSqm4077.934077.939.45FalseNoneNoneFalseNoneFalse38536.43850
3689235135455None12.60V2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1291.391291.394.0FalseNoneNoneFalseNoneFalse5165.560
3689236135455None12.61V2Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1215.281215.284.0FalseNoneNoneFalseNoneFalse4861.120
3689237135455None12.62V2Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos290.93290.938.0FalseNoneNoneFalseNoneFalse2327.440
3689238135455None12.63V2Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos159.58159.588.0FalseNoneNoneFalseNoneFalse1276.640
3689239135455None12.64V2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos67.5267.524.0FalseNoneNoneFalseNoneFalse270.080
3689240135455None12.75.1V2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos337.58337.588.0FalseNoneNoneFalseNoneFalse2700.640
3689241135455None10.6.3V2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick ma sonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmEach73.6573.6524.0FalseNoneNoneFalseNoneFalse1767.60
3689242135455None11.34AV2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg206.23206.23848.61FalseNoneNoneFalseNoneFalse175008.84030
3689243135455None12.54V2Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 9x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.m390.36390.3619.8FalseNoneNoneFalseNoneFalse7729.1280
3689244135455None12.55.2V2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with one side prelamSqm2504.212504.216.3FalseNoneNoneFalseNoneFalse15776.5230
3689245135455None12.59V2Providing and fixing aluminium die cast body tubular type universal hy draulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1367.51367.513.0FalseNoneNoneFalseNoneFalse17777.50
3689246135455None8.4.2V2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm383.0383.0270.5FalseNoneNoneFalseNoneFalse103601.50
3689247135455None8.5.2V2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Inside)Sqm428.42428.42397.34FalseNoneNoneFalseNoneFalse170228.40280
3689248135455None8.51V2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm122.76122.76667.85FalseNoneNoneFalseNoneFalse81985.2660
3689249135455None8.8V2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (For External)Sqm455.42455.42400.56FalseNoneNoneFalseNoneFalse182423.03520
3689250135455None8.79V2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m63.8363.83333.74FalseNoneNoneFalseNoneFalse21302.62420
3689251135455None9.21.2V2Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mmSqm1519.711519.71243.74FalseNoneNoneFalseNoneFalse370414.11540
3689252135455None9.20.2V2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mmSqm256.56256.56243.74FalseNoneNoneFalseNoneFalse62533.93440
3689253135455None8.2.1V2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm362.13362.1333.78FalseNoneNoneFalseNoneFalse12232.75140
3689254135455None15.7V2Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline aterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)Cum754.95754.9527.84FalseNoneNoneFalseNoneFalse21017.8080
3689255135455None9.11V2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 ncluding pointing the joints with white cement and matching pigments etc., complete.Sqm1091.31091.37.89FalseNoneNoneFalseNoneFalse8610.3570
3689256135455None9.39V2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1778.731778.7333.78FalseNoneNoneFalseNoneFalse60085.49940
3689257135455None9.14V2Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.Sqm433.33433.3341.67FalseNoneNoneFalseNoneFalse18056.86110
3689258135455None8.39V2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.9155.9667.85FalseNoneNoneFalseNoneFalse104117.8150
3689259135455None8.32V2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm191.5191.5400.56FalseNoneNoneFalseNoneFalse76707.240
3689260135455None8.34.3V2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm61.3861.3840.41FalseNoneNoneFalseNoneFalse2480.36580
3689261135455None8.40V2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm141.17141.1740.41FalseNoneNoneFalseNoneFalse5704.67970
3689262135455None8.34.1V2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.0665.0624.3FalseNoneNoneFalseNoneFalse1580.9580
3689263135455None8.47V2Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.72165.7224.3FalseNoneNoneFalseNoneFalse4026.9960
3689264135455None9.23V2Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3027.153027.1517.89FalseNoneNoneFalseNoneFalse54155.71350
3689265135455None1201W.S & UGD SRPVC pipes of 6 Kg/cm2 for 110mm(1.894)Rmtr313.03313.0360.0FalseNoneNoneFalseNoneFalse18781.80
17228372840000NoneNoneBuildingsWater Supply & Sanitary Works237937.18
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3689266135456None14.28.2.2V2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm diaEach111.82111.824.0FalseNoneNoneFalseNoneFalse447.280
3689267135456None16.7.4V5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipesEach168.94168.9410.0FalseNoneNoneFalseNoneFalse1689.40
3689268135456None657V5PVC pipe - OD 75mm and 6 Kg/sqcm, waste linesm149.49149.4930.0FalseNoneNoneFalseNoneFalse4484.70
3689269135456None647V5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary linesm309.93309.9325.0FalseNoneNoneFalseNoneFalse7748.250
3689270135456None13.47V2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameterm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
3689271135456None657V5PVC pipe - OD 75mm and 6 Kg/sqcm - (Shaft Drainage)m149.49149.4910.0FalseNoneNoneFalseNoneFalse1494.90
3689272135456None647V5PVC pipe - OD 110mm and 6 Kg/sqcm - (Shaft Drainage)m309.93309.9330.0FalseNoneNoneFalseNoneFalse9297.90
3689273135456None37.28.1SR18-19Drilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 7.50 cms thickNos163.85163.855.0FalseNoneNoneFalseNoneFalse819.250
3689274135456None37.28.2SR18-19Drilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 10 cms thickNos196.38196.385.0FalseNoneNoneFalseNoneFalse981.90
3689275135456None14.31V2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1482.791482.792.0FalseNoneNoneFalseNoneFalse2965.580
3689276135456None12.5SR18-19KSRB 11-5 : Providing and fixing white vitreous china clay, water closet European type (Pedestal type, P-trap) with black solid plastic seat and lid, C. P brass hinges, rubber buffers. 10 litre low level, PVC flushing cistern ( all are approved make ) with fittings, C. I I M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and rnaking good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11Each6198.966198.964.0FalseNoneNoneFalseNoneFalse24795.840
3689277135456None14.11.2V2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mmEach6176.666176.664.0FalseNoneNoneFalseNoneFalse24706.640
3689278135456None166V2C.P. Brass stop cock (concealed) 15 mmNo638.09638.094.0FalseNoneNoneFalseNoneFalse2552.360
3689279135456None14.7.1V2White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3745.863745.864.0FalseNoneNoneFalseNoneFalse14983.440
3689280135456None13.32.1V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipesm375.56375.5625.0FalseNoneNoneFalseNoneFalse9389.00
3689281135456None13.32.2V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesm460.64460.6455.0FalseNoneNoneFalseNoneFalse25335.20
3689282135456None13.33.2V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(External work). External & Shafts & Terrace. 20 mm nominal dia Pipesm263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3689283135456None13.33.3V2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(External work). External & Shafts & Terrace. 25 mm nominal dia Pipesm359.76359.7650.0FalseNoneNoneFalseNoneFalse17988.00
3689284135456None109V2Brass full way valve with C.I. wheel (screwed end) 25 mm diaNo442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3689285135456None16.9V5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)Each6628.796628.798.0FalseNoneNoneFalseNoneFalse53030.320
3689286135456None12.112.2V2Providing and fixing 100 mm sand cast Iron grating for gully trap.Each55.4655.464.0FalseNoneNoneFalseNoneFalse221.840
3689287135456None13.34V2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.9410.942000.0FalseNoneNoneFalseNoneFalse21880.00
3689288135456None14.28.2.2V2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm diam111.82111.824.0FalseNoneNoneFalseNoneFalse447.280
3689289135456None16.7.4V5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipesEach168.94168.945.0FalseNoneNoneFalseNoneFalse844.70
17228372840000NoneNoneBuildingsElectrical Works510372.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3689290135457None2.2.1V6SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral) &1x1.0 sqmm(Earthwire)FRLSmulti strandPVCinsulated copperwire(confirmingtoIS-694: andlatest amendments)without control switchshallbefixedontheexistingplasticsheet/gangbox, theother endof thewires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxPoint326.94326.9412.0FalseNoneNoneFalseNoneFalse3923.280
3689291135457None2.2.2V6SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral) &1x1.0 sqmm(Earthwire)FRLSmulti strandPVCinsulated copperwire(confirmingtoIS-694: andlatest amendments)without control switchshallbefixedontheexistingplasticsheet/gangbox, theother endof thewires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet. Mediumpointabove3Mtrupto6Mtrfromtappingpoint toout letvia switch boxPoint460.64460.6417.0FalseNoneNoneFalseNoneFalse7830.880
3689292135457None2.2.3V6SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral) &1x1.0 sqmm(Earthwire)FRLSmulti strandPVCinsulated copperwire(confirmingtoIS-694: andlatest amendments)without control switchshallbefixedontheexistingplasticsheet/gangbox, theother endof thewires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet. Longpoint above6Mtrupto10Mtr fromtappingpoint toout letvia switch boxPoint674.55674.5522.0FalseNoneNoneFalseNoneFalse14840.10
3689293135457None2.2.4V6SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral) &1x1.0 sqmm(Earthwire)FRLSmulti strandPVCinsulated copperwire(confirmingtoIS-694: andlatest amendments)without control switchshallbefixedontheexistingplasticsheet/gangbox, theother endof thewires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet. Twooutlet inarow,above3Mtrupto6Mtrfromtappingpoint toout let via switchesPoint822.83822.834.0FalseNoneNoneFalseNoneFalse3291.320
3689294135457None3.4.2V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 WayEach193.25193.2510.0FalseNoneNoneFalseNoneFalse1932.50
3689295135457None3.4.3V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 WayEach215.13215.133.0FalseNoneNoneFalseNoneFalse645.390
3689296135457None3.4.4V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 WayEach267.39267.392.0FalseNoneNoneFalseNoneFalse534.780
3689297135457None3.4.5V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 WayEach317.22317.223.0FalseNoneNoneFalseNoneFalse951.660
3689298135457None3.4.6V6Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 WayEach387.71387.7118.0FalseNoneNoneFalseNoneFalse6978.780
3689299135457None3.5.2V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach195.68195.6810.0FalseNoneNoneFalseNoneFalse1956.80
3689300135457None3.5.3V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach212.7212.73.0FalseNoneNoneFalseNoneFalse638.10
3689301135457None3.5.4V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach284.4284.42.0FalseNoneNoneFalseNoneFalse568.80
3689302135457None3.5.5V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach345.17345.173.0FalseNoneNoneFalseNoneFalse1035.510
3689303135457None3.5.6V6Supplying and fixing superior quality modular switch mounting polycarbonateplatewithnecessarysupportingbackplatewithrequired nos. ofmachine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach418.1418.118.0FalseNoneNoneFalseNoneFalse7525.80
3689304135457None3.6.1V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach123.97123.97107.0FalseNoneNoneFalseNoneFalse13264.790
3689305135457None3.6.2V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way SwitchEach201.76201.762.0FalseNoneNoneFalseNoneFalse403.520
3689306135457None3.6.3V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socketEach207.83207.8353.0FalseNoneNoneFalseNoneFalse11014.990
3689307135457None3.6.4V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach433.9433.913.0FalseNoneNoneFalseNoneFalse5640.70
3689308135457None3.6.7V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach218.77218.772.0FalseNoneNoneFalseNoneFalse437.540
3689309135457None3.6.9V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 32A DP SwitchEach396.22396.228.0FalseNoneNoneFalseNoneFalse3169.760
3689310135457None3.6.10V6Supplyingandfixingofmodular switch&connectedaccessorieson existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach286.83286.8310.0FalseNoneNoneFalseNoneFalse2868.30
3689311135457None1.13V6Supplying And Fixing Metal Fan Box with Round Hook.No142.2142.213.0FalseNoneNoneFalseNoneFalse1848.60
3689312135457None1.2.1V6Supplying heavygaugePVCconduitpipe......mmdia..........mmthick confirming toIS2509withsuitablesizebends,metal/PVCJunction boxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab. The conduit shouldbe tied to the reinforcement rods byusingbinding wiresandunusedwaysof junction boxesandpipeends should be covered usingPVCendenclosures, runwith18SWGGI fishwire wherever necessary. 19/20 mm dia 2 mm thickMtr80.2280.22100.0FalseNoneNoneFalseNoneFalse8022.00
3689313135457None1.2.2V6Supplying heavygaugePVCconduitpipe......mmdia..........mmthick confirming toIS2509withsuitablesizebends,metal/PVCJunction boxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab. The conduit shouldbe tied to the reinforcement rods byusingbinding wiresandunusedwaysof junction boxesandpipeends should be covered usingPVCendenclosures, runwith18SWGGI fishwire wherever necessary. 25 mm dia 2 mm thickMtr94.894.8100.0FalseNoneNoneFalseNoneFalse9480.00
3689314135457None1.2.3V6Supplying heavygaugePVCconduitpipe......mmdia..........mmthick confirming toIS2509withsuitablesizebends,metal/PVCJunction boxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab. The conduit shouldbe tied to the reinforcement rods byusingbinding wiresandunusedwaysof junction boxesandpipeends should be covered usingPVCendenclosures, runwith18SWGGI fishwire wherever necessary. 32 mm dia 2.5 mm thickMtr125.19125.1950.0FalseNoneNoneFalseNoneFalse6259.50
3689315135457None1.3.1V6Supplying heavy gauge PVCConduit Pipe .... dia .......mmthick withsuitablesizebends,metal junctionboxesadhesivepasteetc.,by groovecuttinginthewall andfixing bybracingUor Jhooks and cementplasteringuptothewallsurfaceandrunwith18SWGGIfish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thickMtr82.6582.65100.0FalseNoneNoneFalseNoneFalse8265.00
3689316135457None1.3.2V6Supplying heavy gauge PVCConduit Pipe .... dia .......mmthick withsuitablesizebends,metal junctionboxesadhesivepasteetc.,by groovecuttinginthewall andfixing bybracingUor Jhooks and cementplasteringuptothewallsurfaceandrunwith18SWGGIfish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thickMtr96.0296.02100.0FalseNoneNoneFalseNoneFalse9602.00
3689317135457None1.3.3V6Supplying heavy gauge PVCConduit Pipe .... dia .......mmthick withsuitablesizebends,metal junctionboxesadhesivepasteetc.,by groovecuttinginthewall andfixing bybracingUor Jhooks and cementplasteringuptothewallsurfaceandrunwith18SWGGIfish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thickMtr120.32120.3250.0FalseNoneNoneFalseNoneFalse6016.00
3689318135457None2.3.2V6Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated100Vgrade,multistrandcopperwirewithlowconductor resistance singlecore inopenorconcealedsystemofwiringwithspecifiedIS 694:2010. 1.5 mm2Mtr31.631.6100.0FalseNoneNoneFalseNoneFalse3160.00
3689319135457None2.3.3V6Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated100Vgrade,multistrandcopperwirewithlowconductor resistance singlecore inopenorconcealedsystemofwiringwithspecifiedIS 694:2010. 2.5 mm2Mtr51.0551.05300.0FalseNoneNoneFalseNoneFalse15315.00
3689320135457None2.3.4V6Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated100Vgrade,multistrandcopperwirewithlowconductor resistance singlecore inopenorconcealedsystemofwiringwithspecifiedIS 694:2010. 4 mm2Mtr76.5776.57200.0FalseNoneNoneFalseNoneFalse15314.00
3689321135457None2.3.5V6Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated100Vgrade,multistrandcopperwirewithlowconductor resistance singlecore inopenorconcealedsystemofwiringwithspecifiedIS 694:2010. 6 mm2Mtr111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3689322135457None5.19.4V6Supplyingand fixing regularMCBdistributionboards onwall/ood board/ flushmountingusingrequiredclamps, bolts, nuts etc.,with provision for fixing suitable type capacityMCB's single phase/3 phase/singledoorwith wdercoatedpaintingMadeoutof14SWG MS enclosure. I- Single Door. 12 Way SP & NEach2264.292264.291.0FalseNoneNoneFalseNoneFalse2264.290
3689323135457None5.19.11V6Supplyingand fixing regularMCBdistributionboards onwall/ood board/ flushmountingusingrequiredclamps, bolts, nuts etc.,with provision for fixing suitable type capacityMCB's single phase/3 phase/singledoorwith wdercoatedpaintingMadeoutof14SWG MS enclosure. III - Double Door. 4 Way TP & NEach4907.794907.791.0FalseNoneNoneFalseNoneFalse4907.790
3689324135457None5.18.1V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 6-32 A SPEach504.39504.3934.0FalseNoneNoneFalseNoneFalse17149.260
3689325135457None5.18.9V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 50-63 A TPNEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3689326135457None5.18.4V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 6-32 A DPEach898.18898.183.0FalseNoneNoneFalseNoneFalse2694.540
3689327135457None5.20.8V6Supplying, fixing andwiringResidualcurrentcircuitbreaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 4 poleEach6255.666255.661.0FalseNoneNoneFalseNoneFalse6255.660
3689328135457None32.07V61.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmmKm169607.85169607.850.1FalseNoneNoneFalseNoneFalse16960.7850
3689329135457None31.05V6Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmmKm25384.8425384.840.1FalseNoneNoneFalseNoneFalse2538.4840
3689330135457None6.11.2SR19-20Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 25mm diaEach102.09102.098.0FalseNoneNoneFalseNoneFalse816.720
3689331135457None49.05BSRSupplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 50mmMtr465.5465.510.0FalseNoneNoneFalseNoneFalse4655.00
3689332135457None6.17.7SR 19-20Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 25 sqmm Long BarrelEach24.3124.318.0FalseNoneNoneFalseNoneFalse194.480
3689333135457None29.03BSREarth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soilcm472.79472.7950.0FalseNoneNoneFalseNoneFalse23639.50
3689334135457None6.2SR19-20Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No5043.915043.912.0FalseNoneNoneFalseNoneFalse10087.820
3689335135457NoneSR 19-20-6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripMtr91.1691.1620.0FalseNoneNoneFalseNoneFalse1823.20
3689336135457None11.3.2V6Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach838.63838.6328.0FalseNoneNoneFalseNoneFalse23481.640
3689337135457None11.5.2V6Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1075.631075.638.0FalseNoneNoneFalseNoneFalse8605.040
3689338135457None11.11.3V6Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should greater than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500KEach181.09181.094.0FalseNoneNoneFalseNoneFalse724.360
3689339135457None12.46V6Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach76.5776.574.0FalseNoneNoneFalseNoneFalse306.280
3689340135457None11.8.2V6SupplyofLEDStreetlight luminairewithpressurediecastaluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuserwith Injectionmouldedpolycarbonatematerial, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenanceof70%, maximumlightintensityshouldbebetween 60degrees to 70degrees. CCT greater than 5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaire greater than IK08. Power Factor greater than 0.9 withmains, SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/ miss-wiring protection. Compatibleforpolemountingwithouterdiaof40mmto 50mm.UniversalVoltagedriver tooperatewidevoltage range from100Vto 270V50/60Hz application. Compliance to IS 10322/IEC60598,LM79& LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbe Engraved /Embossing on thediecast housing/ Bodypart.Warrantyof2Years againstanymanufacturing defectworkingunderstandardelectricalconditionsas mentioned above should be given by LEDmanufacturer &Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40WNo4890.774890.772.0FalseNoneNoneFalseNoneFalse9781.540
3689341135457None6.1V6Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1813.381813.384.0FalseNoneNoneFalseNoneFalse7253.520
3689342135457None6.3.1V6Supplyingcapacitor typeceilingfancompletewithdownrodblades, shackle,canopiesetc,foroperationon230V,50cycles. Singlephase ACsupplyconforming toISS-374-1979andwithdoubleballbearing system. 48" Sweep (1200 mm) Regular modelEach3626.753626.7513.0FalseNoneNoneFalseNoneFalse47147.750
3689343135457None13.7.1V6Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach148.28148.2836.0FalseNoneNoneFalseNoneFalse5338.080
3689344135457None13.11V6Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each382.85382.8513.0FalseNoneNoneFalseNoneFalse4977.050
3689345135457None13.13V6Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each859.29859.294.0FalseNoneNoneFalseNoneFalse3437.160
3689346135457None13.4.1V6Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1775.71775.72.0FalseNoneNoneFalseNoneFalse3551.40
3689347135457None13.5V6Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each196.89196.892.0FalseNoneNoneFalseNoneFalse393.780
3689348135457None5.42.2V6Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.520.5250000.0FalseNoneNoneFalseNoneFalse26000.00
3689349135457None5.40.1V6Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum StripsMtr2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3689350135457None5.41.1V6Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmMtr370.7370.710.0FalseNoneNoneFalseNoneFalse3707.00
3689351135457None5.41.4V6Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelMtr918.84918.8410.0FalseNoneNoneFalseNoneFalse9188.40
3689352135457None5.14.6V6Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs). FOUR POLE. 95/100 AEach20182.9320182.931.0FalseNoneNoneFalseNoneFalse20182.930
3689353135457None5.18.1V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 6-32 A SPEach504.39504.393.0FalseNoneNoneFalseNoneFalse1513.170
3689354135457None5.18.4V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 6-32 A DPEach898.18898.183.0FalseNoneNoneFalseNoneFalse2694.540
3689355135457None5.18.9V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 50-63 A TPNEach3753.163753.163.0FalseNoneNoneFalseNoneFalse11259.480
3689356135457None5.18.9V6Supplying&fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898. 50-63 A TPNEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3689357135457None5.33V6Supplyingofmulti functiondigitalmeterwith three lineback light LCD type display for voltage,Current, frequency, Power, power factor, kVA, kWH, kVARsuitable for 3phase,4wireLTnetwork withIP54degreeofprotectionandcompletelywiredasrequiredwith communication Port and Class 0.5s accuracyEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3689358135457None5.38V6Supplying and fixing of LEDtype panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3689359135457None5.34V6Supplying, fixingandwiring50/5 to400/5A5VAburdenCurrent Transformer Class 0.5 accuracy with Tape Wound.Each683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17228372850000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17228372850000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17228372850001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17228372850000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17228372850000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17228373790000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17228373920000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17228374020000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17228374100000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17228374180000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17228374270000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17228374370000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17228374610000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17228374780000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17228376280000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17228376700000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17228376830000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17228377040000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17228377590000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17228378660000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17228378740000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17228378820000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17228379020000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24.None
17228379100000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17228379200000NoneNoneELIGIBILITYThe Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b)(c)(d)and (e).None
17228379310000NoneNoneELIGIBILITYAs per GO No:FD-CAM/16/2022 (P-2) dated 22nd August 2022 , Banker Certificate / Line of credit shall be uploaded in the format mentioned in the SECTION -11 as per bid documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 49.95 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submittedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one similar nature of work of value not less than Rs. 24.98 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work 1 PCC/RCC 94.00 Cum 2 TMT Steel 6.50 T 3 Plastering 480.00 Sqm 4 Painting 382.00 Sqm 5 Flooring 149.00 Sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/Government Electrical Inspectorate and should have executed similar building electrical works totaling Rs. 2.50 Lakhs in any one financial year Note:Consent letter of the subcontractor should be uploadedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/KUWS&DB and should possess valid licence for executing water supply or sanitary engineering works issued by competent authority and should have executed similar water supply or sanitary engineering works total Rs. 1.20 Lakh in any one financial year, Note:Consent letter of the sub contractor should be uploadedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneKPWD Registration Certificate Class III & aboveCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PWD Registration certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
KPWD Class III & above Registration CertificateTrueTechnical Bid
GST RegistrationTrueTechnical Bid
Work done certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone