3768586 | 141918 | None | code01 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1952.01 | 1952.01 | 5.9 | False | None | None | False | None | False | 11516.859 | 0 |
3768587 | 141918 | None | code02 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar | Cum | 828.92 | 828.92 | 2.04 | False | None | None | False | None | False | 1690.9968 | 0 |
3768588 | 141918 | None | code03 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 463.31 | 463.31 | 55.7466 | False | None | None | False | None | False | 25827.957246 | 0 |
3768589 | 141918 | None | code04 | Dismantling steel work in single sections including dismembering and stacking within to the appropriate disposal area as per direction of Engineer-in-charge. | Kg | 2.1 | 2.1 | 472.86 | False | None | None | False | None | False | 993.006 | 0 |
3768590 | 141918 | None | code05 | Dismantling cement asbestos or other hard board ceiling or partitionwalls including stacking of serviceable materials and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 29.42 | 29.42 | 26.27 | False | None | None | False | None | False | 772.8634 | 0 |
3768591 | 141918 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( consider 70% of finished rate of concrete for column shuttering) | Cum | 11048.32 | 11048.32 | 83.47 | False | None | None | False | None | False | 922203.2704 | 0 |
3768592 | 141918 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(consider 60% of finished rate of concrete for roof beam shuttering) | Cum | 10398.42 | 10398.42 | 79.24 | False | None | None | False | None | False | 823970.8008 | 0 |
3768593 | 141918 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (consider 50% of finished rate of concrete for roof beam shuttering) | Cum | 9423.57 | 9423.57 | 116.33 | False | None | None | False | None | False | 1096243.8981 | 0 |
3768594 | 141918 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 60% of finished rate of concrete for lintel shuttering) | Cum | 10398.42 | 10398.42 | 18.46 | False | None | None | False | None | False | 191954.8332 | 0 |
3768595 | 141918 | None | code10 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 87.2 | 87.2 | 44810.92 | False | None | None | False | None | False | 3907512.224 | 0 |
3768596 | 141918 | None | code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1114.69 | 1114.69 | 714.72 | False | None | None | False | None | False | 796691.2368 | 0 |
3768597 | 141918 | None | code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding a+nd curing, usage charges of machinery etc complete as per specifications. | Sqm | 987.56 | 987.56 | 34.99 | False | None | None | False | None | False | 34554.7244 | 0 |
3768598 | 141918 | None | code13 | Chicken Mesh | Sqm | 12.61 | 12.61 | 221.68 | False | None | None | False | None | False | 2795.3848 | 0 |
3768599 | 141918 | None | code14 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... | Sqm | 275.26 | 275.26 | 773.41 | False | None | None | False | None | False | 212888.8366 | 0 |
3768600 | 141918 | None | code15 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 241.64 | 241.64 | 993.52 | False | None | None | False | None | False | 240074.1728 | 0 |
3768601 | 141918 | None | code16 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 338.29 | 338.29 | 1055.62 | False | None | None | False | None | False | 357105.6898 | 0 |
3768602 | 141918 | None | code17 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7606.34 | 7606.34 | 61.05 | False | None | None | False | None | False | 464367.057 | 0 |
3768603 | 141918 | None | code18 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame havin overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5116.42 | 5116.42 | 4.32 | False | None | None | False | None | False | 22102.9344 | 0 |
3768604 | 141918 | None | code19 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Consider 21 Kg/Sqm) | Kg | 137.63 | 137.63 | 1282.05 | False | None | None | False | None | False | 176448.5415 | 0 |
3768605 | 141918 | None | code20 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 64720.11 | 64720.11 | 0.71 | False | None | None | False | None | False | 45951.2781 | 0 |
3768606 | 141918 | None | code21 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 499.04 | 499.04 | 22.8 | False | None | None | False | None | False | 11378.112 | 0 |
3768607 | 141918 | None | code22 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.- with one side prelam. | Sqm | 3000.51 | 3000.51 | 6.3 | False | None | None | False | None | False | 18903.213 | 0 |
3768608 | 141918 | None | code23 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1555.94 | 1555.94 | 24.0 | False | None | None | False | None | False | 37342.56 | 0 |
3768609 | 141918 | None | code24 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 874.1 | 874.1 | 24.0 | False | None | None | False | None | False | 20978.4 | 0 |
3768610 | 141918 | None | code25 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 652.42 | 652.42 | 24.0 | False | None | None | False | None | False | 15658.08 | 0 |
3768611 | 141918 | None | code26 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 183.86 | 183.86 | 24.0 | False | None | None | False | None | False | 4412.64 | 0 |
3768612 | 141918 | None | code27 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 116.62 | 116.62 | 24.0 | False | None | None | False | None | False | 2798.88 | 0 |
3768613 | 141918 | None | code28 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 49.38 | 49.38 | 16.0 | False | None | None | False | None | False | 790.08 | 0 |
3768614 | 141918 | None | code29 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Nos | 211.17 | 211.17 | 96.0 | False | None | None | False | None | False | 20272.32 | 0 |
3768615 | 141918 | None | code30 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | Nos | 31.52 | 31.52 | 80.0 | False | None | None | False | None | False | 2521.6 | 0 |
3768616 | 141918 | None | code31 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Mtr | 13.35 | 13.35 | 330.2 | False | None | None | False | None | False | 4408.17 | 0 |
3768617 | 141918 | None | code32 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 3092.97 | 3092.97 | 24.15 | False | None | None | False | None | False | 74695.2255 | 0 |
3768618 | 141918 | None | code33 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.- with one side prelam. | Sqm | 3000.51 | 3000.51 | 12.6 | False | None | None | False | None | False | 37806.426 | 0 |
3768619 | 141918 | None | code34 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 924.53 | 924.53 | 8.0 | False | None | None | False | None | False | 7396.24 | 0 |
3768620 | 141918 | None | code35 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 38.87 | 38.87 | 28.56 | False | None | None | False | None | False | 1110.1272 | 0 |
3768621 | 141918 | None | code36 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 94.55 | 94.55 | 110.16 | False | None | None | False | None | False | 10415.628 | 0 |
3768622 | 141918 | None | code37 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 123.97 | 123.97 | 1987.8 | False | None | None | False | None | False | 246427.566 | 0 |
3768623 | 141918 | None | code38 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.2 | 87.2 | 1987.8 | False | None | None | False | None | False | 173336.16 | 0 |
3768624 | 141918 | None | code39 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 142.88 | 142.88 | 1787.57 | False | None | None | False | None | False | 255408.0016 | 0 |
3768625 | 141918 | None | code40 | Providing and laying Cement concrete flooring 40 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. (Outer Seater) | Sqm | 420.24 | 420.24 | 46.08 | False | None | None | False | None | False | 19364.6592 | 0 |
3768626 | 141918 | None | code41 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1157.76 | 1157.76 | 521.96 | False | None | None | False | None | False | 604304.4096 | 0 |
3768627 | 141918 | None | code42 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6017.84 | 6017.84 | 39.65 | False | None | None | False | None | False | 238607.356 | 0 |
3768628 | 141918 | None | code43 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. | Sqm | 298.37 | 298.37 | 39.65 | False | None | None | False | None | False | 11830.3705 | 0 |
3768629 | 141918 | None | code44 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1089.47 | 1089.47 | 37.86 | False | None | None | False | None | False | 41247.3342 | 0 |
3768630 | 141918 | None | code45 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 1983.53 | 1983.53 | 220.87 | False | None | None | False | None | False | 438102.2711 | 0 |
3768631 | 141918 | None | code46 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chajjas with plastering ( labour charges only ) as per specifications. Specification No . KBS | Mtr | 46.67 | 46.67 | 43.2 | False | None | None | False | None | False | 2016.144 | 0 |
3768632 | 141918 | None | code47 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2119.06 | 2119.06 | 2.19 | False | None | None | False | None | False | 4640.7414 | 0 |
3768633 | 141918 | None | code48 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Dummy Column) | Cum | 10936.85 | 10936.85 | 2.16 | False | None | None | False | None | False | 23623.596 | 0 |
3768634 | 141918 | None | code49 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10293.5 | 10293.5 | 4.52 | False | None | None | False | None | False | 46526.62 | 0 |
3768635 | 141918 | None | code50 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates (Dummy Columns) | Cum | 10395.84 | 10395.84 | 9.54 | False | None | None | False | None | False | 99176.3136 | 0 |
3768636 | 141918 | None | code51 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 5957.12 | 5957.12 | 0.46 | False | None | None | False | None | False | 2740.2752 | 0 |
3768637 | 141918 | None | code52 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy | No. | 166.4 | 166.4 | 40.0 | False | None | None | False | None | False | 6656.0 | 0 |
3768638 | 141918 | None | code53 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 86.32 | 86.32 | 3115.82 | False | None | None | False | None | False | 268957.5824 | 0 |
3768639 | 141918 | None | code54 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC Chajjas with plastering ( labour charges only ) as per specifications. Specification No . KBS | Mtr | 34.32 | 34.32 | 1.95 | False | None | None | False | None | False | 66.924 | 0 |
3768640 | 141918 | None | code55 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1103.44 | 1103.44 | 60.45 | False | None | None | False | None | False | 66702.948 | 0 |
3768641 | 141918 | None | code56 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaSFolding a+nd curing, usage charges of machinery etc complete as per specifications. | Sqm | 977.6 | 977.6 | 180.45 | False | None | None | False | None | False | 176407.92 | 0 |
3768642 | 141918 | None | code57 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, includingapplying a priming coat of approved steel primer. Using M.S.angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 3806.4 | 3806.4 | 0.05 | False | None | None | False | None | False | 190.32 | 0 |
3768643 | 141918 | None | code58 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... (Inside) | Sqm | 272.48 | 272.48 | 51.88 | False | None | None | False | None | False | 14136.2624 | 0 |
3768644 | 141918 | None | code59 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. | Sqm | 305.76 | 305.76 | 49.3 | False | None | None | False | None | False | 15073.968 | 0 |
3768645 | 141918 | None | code60 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 334.88 | 334.88 | 414.29 | False | None | None | False | None | False | 138737.4352 | 0 |
3768646 | 141918 | None | code61 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 122.72 | 122.72 | 227.64 | False | None | None | False | None | False | 27935.9808 | 0 |
3768647 | 141918 | None | code62 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 86.32 | 86.32 | 227.64 | False | None | None | False | None | False | 19649.8848 | 0 |
3768648 | 141918 | None | code63 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 141.44 | 141.44 | 466.08 | False | None | None | False | None | False | 65922.3552 | 0 |
3768649 | 141918 | None | code64 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 38.48 | 38.48 | 3.38 | False | None | None | False | None | False | 130.0624 | 0 |
3768650 | 141918 | None | code65 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.6 | 93.6 | 3.38 | False | None | None | False | None | False | 316.368 | 0 |
3768651 | 141918 | None | code66 | PVC pipes of 6 Kg/cm2 for 110mm(1.894) | Mtr | 265.2 | 265.2 | 247.5 | False | None | None | False | None | False | 65637.0 | 0 |
3768652 | 141918 | None | code67 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 774.8 | 774.8 | 1092.59 | False | None | None | False | None | False | 846538.732 | 0 |
3768653 | 141918 | None | code68 | Chicken Mesh | Sqm | 12.48 | 12.48 | 63.06 | False | None | None | False | None | False | 786.9888 | 0 |
3768654 | 141918 | None | code69 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Headroom roof | Sqm | 589.8 | 589.8 | 28.8 | False | None | None | False | None | False | 16986.24 | 0 |
3768655 | 141918 | None | code70 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top Crimp curve | Sqm | 386.13 | 386.13 | 28.8 | False | None | None | False | None | False | 11120.544 | 0 |
3768656 | 141918 | None | code71 | Gutter (600 mm over all girth) | m | 906.98 | 906.98 | 4.0 | False | None | None | False | None | False | 3627.92 | 0 |
3768657 | 141918 | None | code72 | Ridges plain (500 - 600mm) | m | 382.95 | 382.95 | 7.2 | False | None | None | False | None | False | 2757.24 | 0 |
3768658 | 141918 | None | code73 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 144.27 | 144.27 | 230.4 | False | None | None | False | None | False | 33239.808 | 0 |
3768659 | 141918 | None | code74 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. | l | 8.16 | 8.16 | 6000.0 | False | None | None | False | None | False | 48960.0 | 0 |
3768660 | 141918 | None | code75 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern | Each | 10254.0 | 10254.0 | 5.0 | False | None | None | False | None | False | 51270.0 | 0 |
3768661 | 141918 | None | code76 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 394.0 | 394.0 | 200.0 | False | None | None | False | None | False | 78800.0 | 0 |
3768662 | 141918 | None | code77 | Supply and delivery at site special moulded variety110mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments | Nos | 178.0 | 178.0 | 30.0 | False | None | None | False | None | False | 5340.0 | 0 |
3768663 | 141918 | None | code78 | Supply and delivery at site special moulded variety110mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Nos | 315.0 | 315.0 | 6.0 | False | None | None | False | None | False | 1890.0 | 0 |
3768664 | 141918 | None | code79 | Supply and delivery at site special moulded variety 110mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Nos | 262.0 | 262.0 | 30.0 | False | None | None | False | None | False | 7860.0 | 0 |
3768665 | 141918 | None | code80 | Supply and delivery at site special moulded variety 110mm dia PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Nos | 513.0 | 513.0 | 30.0 | False | None | None | False | None | False | 15390.0 | 0 |
3768666 | 141918 | None | code81 | Supply and delivery at site special moulded variety 110mm dia PVC reducer as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Nos | 272.0 | 272.0 | 25.0 | False | None | None | False | None | False | 6800.0 | 0 |
3768667 | 141918 | None | code82 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of internal work - Exposed on wall - 25mm dia nominal pipes | m | 316.0 | 316.0 | 200.0 | False | None | None | False | None | False | 63200.0 | 0 |
3768668 | 141918 | None | code83 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of internal work - Exposed on wall - 32mm dia nominal pipes | m | 393.0 | 393.0 | 200.0 | False | None | None | False | None | False | 78600.0 | 0 |
3768669 | 141918 | None | code84 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of internal work - Exposed on wall - 50mm dia nominal pipes | m | 767.0 | 767.0 | 50.0 | False | None | None | False | None | False | 38350.0 | 0 |
3768670 | 141918 | None | code85 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Each | 3599.0 | 3599.0 | 4.0 | False | None | None | False | None | False | 14396.0 | 0 |
3768671 | 141918 | None | code86 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid | Each | 4026.0 | 4026.0 | 12.0 | False | None | None | False | None | False | 48312.0 | 0 |
3768672 | 141918 | None | code87 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : | Each | 1476.0 | 1476.0 | 1.0 | False | None | None | False | None | False | 1476.0 | 0 |
3768673 | 141918 | None | code88 | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). -do- 15cms x 10cms | Each | 1530.0 | 1530.0 | 7.0 | False | None | None | False | None | False | 10710.0 | 0 |
3768674 | 141918 | None | code89 | Supplying, installing and testing 15mm CP health faucet and angular stop cock of approved make with necessary CP flexible hose 750mm long; nozzle, CP wall flange complete.( Flow rate 1.8 liters per minute at 60 PSI) | Nos | 2054.69 | 2054.69 | 4.0 | False | None | None | False | None | False | 8218.76 | 0 |
3768675 | 141918 | None | code90 | Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. Make: Jaquar / equivalent | Unit | 485.8 | 485.8 | 6.0 | False | None | None | False | None | False | 2914.8 | 0 |
3768676 | 141918 | None | code91 | Supplying & fixing of CP sink cock with extended swivel spout with wall flange etc complete. Make: Jaquar / equivalent | Nos | 1897.37 | 1897.37 | 4.0 | False | None | None | False | None | False | 7589.48 | 0 |
3768677 | 141918 | None | code92 | Providing & Fixing in position heavy duty C P grating with frame of below mentioned sizes including jointing and fixing material complete. Make: Jaquar / equivalent | Nos | 165.97 | 165.97 | 8.0 | False | None | None | False | None | False | 1327.76 | 0 |
3768678 | 141918 | None | code93 | Providing Wall Green Board in CM 1:3 with two coats of black paints including finishing etc. complete with all lead and lift as directed by the Engineer incharge | Sqm | 1530.0 | 1530.0 | 44.1 | False | None | None | False | None | False | 67473.0 | 0 |
3768679 | 141918 | None | code94 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle | ha | 162785.32 | 162785.32 | 0.001 | False | None | None | False | None | False | 162.78532 | 0 |
3768680 | 141918 | None | code95 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth (Consider 10% Qty as Hard rock) | Cum | 280.16 | 280.16 | 1.83 | False | None | None | False | None | False | 512.6928 | 0 |
3768681 | 141918 | None | code96 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m FOOTING (Consider 90% Qty as Hard rock) | Cum | 75.19 | 75.19 | 16.43 | False | None | None | False | None | False | 1235.3717 | 0 |
3768682 | 141918 | None | code97 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 97.85 | 97.85 | 9.61 | False | None | None | False | None | False | 940.3385 | 0 |
3768683 | 141918 | None | code98 | KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. No. KBS 2.10.2 | Cum | 2281.0 | 2281.0 | 0.96 | False | None | None | False | None | False | 2189.76 | 0 |
3768684 | 141918 | None | code99 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5720.62 | 5720.62 | 1.44 | False | None | None | False | None | False | 8237.6928 | 0 |
3768685 | 141918 | None | code100 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10831.69 | 10831.69 | 1.96 | False | None | None | False | None | False | 21230.1124 | 0 |
3768686 | 141918 | None | code101 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 98.88 | 98.88 | 2794.4 | False | None | None | False | None | False | 276310.272 | 0 |
3768687 | 141918 | None | code102 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 210.12 | 210.12 | 6.85 | False | None | None | False | None | False | 1439.322 | 0 |
3768688 | 141918 | None | code103 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 302.82 | 302.82 | 33.6 | False | None | None | False | None | False | 10174.752 | 0 |
3768689 | 141918 | None | code104 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin- Charge. | Sqm | 52.53 | 52.53 | 38.08 | False | None | None | False | None | False | 2000.3424 | 0 |
3768690 | 141918 | None | code105 | KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 263.68 | 263.68 | 4.0 | False | None | None | False | None | False | 1054.72 | 0 |
3768691 | 141918 | None | code106 | Supplying and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete. Heavy Duty | Set | 2488.48 | 2488.48 | 1.0 | False | None | None | False | None | False | 2488.48 | 0 |
3768692 | 141918 | None | code107 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 251.0 | 251.0 | 250.0 | False | None | None | False | None | False | 62750.0 | 0 |
3768693 | 141918 | None | code108 | Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 361.0 | 361.0 | 25.0 | False | None | None | False | None | False | 9025.0 | 0 |
3768694 | 141918 | None | code109 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 123.0 | 123.0 | 70.0 | False | None | None | False | None | False | 8610.0 | 0 |
3768695 | 141918 | None | code110 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way | Each | 325.0 | 325.0 | 25.0 | False | None | None | False | None | False | 8125.0 | 0 |
3768696 | 141918 | None | code111 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Each | 152.0 | 152.0 | 70.0 | False | None | None | False | None | False | 10640.0 | 0 |
3768697 | 141918 | None | code112 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 363.0 | 363.0 | 25.0 | False | None | None | False | None | False | 9075.0 | 0 |
3768698 | 141918 | None | code113 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 88.0 | 88.0 | 275.0 | False | None | None | False | None | False | 24200.0 | 0 |
3768699 | 141918 | None | code114 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch | Each | 152.0 | 152.0 | 8.0 | False | None | None | False | None | False | 1216.0 | 0 |
3768700 | 141918 | None | code115 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 313.0 | 313.0 | 26.0 | False | None | None | False | None | False | 8138.0 | 0 |
3768701 | 141918 | None | code116 | 32Amps DP switch | Each | 375.0 | 375.0 | 25.0 | False | None | None | False | None | False | 9375.0 | 0 |
3768702 | 141918 | None | code117 | 6/16Amps universal socket | Each | 249.0 | 249.0 | 25.0 | False | None | None | False | None | False | 6225.0 | 0 |
3768703 | 141918 | None | code118 | 16Amps one way switch | Each | 249.0 | 249.0 | 25.0 | False | None | None | False | None | False | 6225.0 | 0 |
3768704 | 141918 | None | code119 | Supplyin and Fixing Metal Fan Box with Round Hook. | No | 163.0 | 163.0 | 26.0 | False | None | None | False | None | False | 4238.0 | 0 |
3768705 | 141918 | None | code120 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick | Mtr | 61.0 | 61.0 | 420.0 | False | None | None | False | None | False | 25620.0 | 0 |
3768706 | 141918 | None | code121 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 550.0 | False | None | None | False | None | False | 38500.0 | 0 |
3768707 | 141918 | None | code122 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick | Mtr | 93.0 | 93.0 | 492.0 | False | None | None | False | None | False | 45756.0 | 0 |
3768708 | 141918 | None | code123 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Mtr | 75.0 | 75.0 | 420.0 | False | None | None | False | None | False | 31500.0 | 0 |
3768709 | 141918 | None | code124 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 275.0 | False | None | None | False | None | False | 22000.0 | 0 |
3768710 | 141918 | None | code125 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick | Mtr | 105.0 | 105.0 | 500.0 | False | None | None | False | None | False | 52500.0 | 0 |
3768711 | 141918 | None | code126 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 850.0 | False | None | None | False | None | False | 22100.0 | 0 |
3768712 | 141918 | None | code127 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm | Mtr | 40.0 | 40.0 | 550.0 | False | None | None | False | None | False | 22000.0 | 0 |
3768713 | 141918 | None | code128 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm | Mtr | 59.0 | 59.0 | 1000.0 | False | None | None | False | None | False | 59000.0 | 0 |
3768714 | 141918 | None | code129 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm | Mtr | 87.0 | 87.0 | 125.0 | False | None | None | False | None | False | 10875.0 | 0 |
3768715 | 141918 | None | code130 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure 8 Way SP & N | Each | 1695.0 | 1695.0 | 2.0 | False | None | None | False | None | False | 3390.0 | 0 |
3768716 | 141918 | None | code131 | III - Double Door 4 Way TP & N | Each | 3053.0 | 3053.0 | 4.0 | False | None | None | False | None | False | 12212.0 | 0 |
3768717 | 141918 | None | code132 | III - Double Door6 Way TP & N | Each | 3735.0 | 3735.0 | 2.0 | False | None | None | False | None | False | 7470.0 | 0 |
3768718 | 141918 | None | code133 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 523.0 | 523.0 | 40.0 | False | None | None | False | None | False | 20920.0 | 0 |
3768719 | 141918 | None | code134 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN | Each | 2399.0 | 2399.0 | 4.0 | False | None | None | False | None | False | 9596.0 | 0 |
3768720 | 141918 | None | code135 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole | Each | 2536.0 | 2536.0 | 2.0 | False | None | None | False | None | False | 5072.0 | 0 |
3768721 | 141918 | None | code136 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole | Each | 2826.0 | 2826.0 | 10.0 | False | None | None | False | None | False | 28260.0 | 0 |
3768722 | 141918 | None | code137 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | Each | 740.0 | 740.0 | 85.0 | False | None | None | False | None | False | 62900.0 | 0 |
3768723 | 141918 | None | code138 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K | Each | 148.0 | 148.0 | 20.0 | False | None | None | False | None | False | 2960.0 | 0 |
3768724 | 141918 | None | code139 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 28.0 | False | None | None | False | None | False | 58380.0 | 0 |
3768725 | 141918 | None | code140 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 119.0 | 119.0 | 100.0 | False | None | None | False | None | False | 11900.0 | 0 |
3768726 | 141918 | None | code141 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. | Each | 281.0 | 281.0 | 42.0 | False | None | None | False | None | False | 11802.0 | 0 |