1723981279000 | 0 | None | None | Buildings | Construction of 22nd Anganwadi Building at Tekkalakotte town in Siruguppa Taluk Ballari Dist | 1675141.26 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3802421 | 144297 | None | code1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 2547.3 | 2547.3 | 6.83 | False | None | None | False | None | False | 17398.059 | 0 | 3802422 | 144297 | None | code2 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge | Cum | 1768.2 | 1768.2 | 5.47 | False | None | None | False | None | False | 9672.054 | 0 | 3802423 | 144297 | None | code3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1080.45 | 1080.45 | 19.95 | False | None | None | False | None | False | 21554.9775 | 0 | 3802424 | 144297 | None | code4 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work. | Cum | 254.1 | 254.1 | 32.25 | False | None | None | False | None | False | 8194.725 | 0 | 3802425 | 144297 | None | code5 | Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6288.45 | 6288.45 | 9.48 | False | None | None | False | None | False | 59614.506 | 0 | 3802426 | 144297 | None | code6 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) | Cum | 6971.11 | 6971.11 | 5.832 | False | None | None | False | None | False | 40655.51352 | 0 | 3802427 | 144297 | None | code7 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) | Cum | 11286.56 | 11286.56 | 0.708 | False | None | None | False | None | False | 7990.88448 | 0 | 3802428 | 144297 | None | code8 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Coulmn | Cum | 12214.76 | 12214.76 | 2.989 | False | None | None | False | None | False | 36509.91764 | 0 | 3802429 | 144297 | None | code9 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Grond Beam ,Plinth Beam | Cum | 11496.24 | 11496.24 | 10.46 | False | None | None | False | None | False | 120250.6704 | 0 | 3802430 | 144297 | None | code10 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Lintel,Roof Beam | Cum | 10418.47 | 10418.47 | 1.9 | False | None | None | False | None | False | 19795.093 | 0 | 3802431 | 144297 | None | code11 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Chejja and Racks | Cum | 8622.18 | 8622.18 | 7.98 | False | None | None | False | None | False | 68804.9964 | 0 | 3802432 | 144297 | None | code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 93929.85 | 93929.85 | 2.57 | False | None | None | False | None | False | 241399.7145 | 0 | 3802433 | 144297 | None | code13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 27.48 | False | None | None | False | None | False | 229937.526 | 0 | 3802434 | 144297 | None | code14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 68.81 | False | None | None | False | None | False | 19218.633 | 0 | 3802435 | 144297 | None | code15 | uPVC DOOR FRAME 42x50 mm PVC Extruded section Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm (0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer incharge | Sqm | 250.95 | 250.95 | 24.6 | False | None | None | False | None | False | 6173.37 | 0 | 3802436 | 144297 | None | code16 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Sqm | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 3802437 | 144297 | None | code17 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification 30 mm thick both side commercial | Sqm | 3155.25 | 3155.25 | 8.19 | False | None | None | False | None | False | 25841.4975 | 0 | 3802438 | 144297 | None | code18 | Soild panel PVC Door Shutter Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. | Sqm | 1667.4 | 1667.4 | 1.575 | False | None | None | False | None | False | 2626.155 | 0 | 3802439 | 144297 | None | code19 | Providing & fixing UPVC windowProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system wiWall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeth touch lock. | Sqm | 5659.5 | 5659.5 | 7.92 | False | None | None | False | None | False | 44823.24 | 0 | 3802440 | 144297 | None | code20 | Providing & fixing Z-Ventilators Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6004.95 | 6004.95 | 1.08 | False | None | None | False | None | False | 6485.346 | 0 | 3802441 | 144297 | None | code21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding14.3 | Kgs | 176.4 | 176.4 | 189.0 | False | None | None | False | None | False | 33339.6 | 0 | 3802442 | 144297 | None | code22 | Inside Plastering Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 292.95 | 292.95 | 110.46 | False | None | None | False | None | False | 32359.257 | 0 | 3802443 | 144297 | None | code23 | External plastering Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 90.25 | False | None | None | False | None | False | 31555.9125 | 0 | 3802444 | 144297 | None | code24 | Ceiling Plastering Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 327.6 | 327.6 | 43.5 | False | None | None | False | None | False | 14250.6 | 0 | 3802445 | 144297 | None | code25 | Wall Putty Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 134.76 | False | None | None | False | None | False | 14149.8 | 0 | 3802446 | 144297 | None | code26 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 133.35 | 133.35 | 209.41 | False | None | None | False | None | False | 27924.8235 | 0 | 3802447 | 144297 | None | code27 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2589.3 | 2589.3 | 49.28 | False | None | None | False | None | False | 127600.704 | 0 | 3802448 | 144297 | None | code28 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 23.7 | False | None | None | False | None | False | 22122.765 | 0 | 3802449 | 144297 | None | code29 | Wall art Painting school building- relaxation with creative wall decor and decorative painting, For all ideas and tips directed by PMC/EIC. | Sqm | 393.75 | 393.75 | 38.44 | False | None | None | False | None | False | 15135.75 | 0 | 3802450 | 144297 | None | code30 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | cm | 4.2 | 4.2 | 3000.0 | False | None | None | False | None | False | 12600.0 | 0 | 3802451 | 144297 | None | code31 | Providing and fixing glass/ceramic steel green dry erase writing boards | Sqm | 2175.0 | 2175.0 | 7.02 | False | None | None | False | None | False | 15268.5 | 0 | 3802452 | 144297 | None | code32 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 8.93 | False | None | None | False | None | False | 2269.113 | 0 | 3802453 | 144297 | None | code33 | Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6288.45 | 6288.45 | 0.26 | False | None | None | False | None | False | 1634.997 | 0 | 3802454 | 144297 | None | code34 | RCC hume pipe Circular Cistern: Supplying precast RCC Circular Hume pipe Cistern with M.S Gate and RCC roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm | Nos | 17221.0 | 17221.0 | 1.0 | False | None | None | False | None | False | 17221.0 | 0 | 3802455 | 144297 | None | code35 | Erection and positioning of RCC Hume pipe pump house/Cistern
on size stone masory platform including transportation charges and
handling,finishing with all necessary tools ,plants and materials
etc.,complete as directed by the Engineer in charge of the work. | Nos | 1976.1 | 1976.1 | 1.0 | False | None | None | False | None | False | 1976.1 | 0 | 3802456 | 144297 | None | code36 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8367.45 | 8367.45 | 2.39 | False | None | None | False | None | False | 19998.2055 | 0 | 3802457 | 144297 | None | code37 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) | Cum | 8353.8 | 8353.8 | 0.58 | False | None | None | False | None | False | 4845.204 | 0 | 3802458 | 144297 | None | code38 | Supplying and delivery 1 HP submersible pump of 100mm dia with specified duty conditions as detailed below and satisfying performance characterstics 1HP, 10 stage. H-46 M, Disch-50 LPM. GLB/SR/2019-20/iteam no12.01.3 Rate RS 13780.00/Each | Nos | 14997.15 | 14997.15 | 1.0 | False | None | None | False | None | False | 14997.15 | 0 | 3802459 | 144297 | None | code39 | Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications. (For 1000 litre capacity) Specification No. KBS 13.22 | l | 7169.4 | 7169.4 | 1.0 | False | None | None | False | None | False | 7169.4 | 0 | 3802460 | 144297 | None | code40 | PVC pipes 32mm dia., 10 kg/sqcm & class 5 Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing andcommissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for9 | m | 67.67 | 67.67 | 125.0 | False | None | None | False | None | False | 8458.75 | 0 | 3802461 | 144297 | None | code41 | PVC pipes 32mm dia., 10 kg/sqcm & class 5 Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS and commissioning
(Contractor will make his own arrangements for procuring water for
testing) etc. for: | m | 48.48 | 48.48 | 125.0 | False | None | None | False | None | False | 6060.0 | 0 | 3802462 | 144297 | None | code42 | Providing and fixing brass bib cock of approved quality :20 mm nominal bore | Nos | 308.05 | 308.05 | 4.0 | False | None | None | False | None | False | 1232.2 | 0 | 3802463 | 144297 | None | code43 | 90mm(weight of pipe -0.917 kg) Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. | m | 212.1 | 212.1 | 18.0 | False | None | None | False | None | False | 3817.8 | 0 | 3802464 | 144297 | None | code44 | Constructing brick masonry chamber for underground C.I. inspection
chamber and bends with bricks in cement mortar 1:4 (1 cement : 4
coarse sand) C.I. cover with frame (light duty) 455x610 mm internal
dimensions, total weight of cover with frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab
with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20
mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size), inside plastering 12
mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete as per standard design: Inside dimensions 455x610 mm and
45 cm deep for single pipe line : With common burnt clay (non modular)
bricks of class designation 3.5 | Each | 5698.42 | 5698.42 | 1.0 | False | None | None | False | None | False | 5698.42 | 0 | 3802465 | 144297 | None | code45 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: | Nos | 4892.44 | 4892.44 | 1.0 | False | None | None | False | None | False | 4892.44 | 0 | 3802466 | 144297 | None | code46 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 3112.82 | 3112.82 | 1.0 | False | None | None | False | None | False | 3112.82 | 0 | 3802467 | 144297 | None | code47 | Stainless steel kitchen sink - with drain board 510 x 1040mm bowl depth 200 mm. | Each | 3232.0 | 3232.0 | 1.0 | False | None | None | False | None | False | 3232.0 | 0 | 3802468 | 144297 | None | code48 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1 9/20 mm dia 2mm thick | m | 72.45 | 72.45 | 150.0 | False | None | None | False | None | False | 10867.5 | 0 | 3802469 | 144297 | None | code49 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.75x75x65mm | Each | 169.05 | 169.05 | 4.0 | False | None | None | False | None | False | 676.2 | 0 | 3802470 | 144297 | None | code50 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.1.5 Sqmm | m | 66.15 | 66.15 | 150.0 | False | None | None | False | None | False | 9922.5 | 0 | 3802471 | 144297 | None | code51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.2.5 Sqmm | Each | 397.95 | 397.95 | 10.0 | False | None | None | False | None | False | 3979.5 | 0 | 3802472 | 144297 | None | code52 | Supplying and fixing of Bakelite DP / Socket/switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP-A 32Amps flush/projected type DP switch | Nos | 243.6 | 243.6 | 1.0 | False | None | None | False | None | False | 243.6 | 0 | 3802473 | 144297 | None | code53 | Supplying and fixing superior qualityh moudlar switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 module. 6A One Way Switch | Each | 107.1 | 107.1 | 12.0 | False | None | None | False | None | False | 1285.2 | 0 | 3802474 | 144297 | None | code54 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp RibFabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 929.25 | 929.25 | 8.0 | False | None | None | False | None | False | 7434.0 | 0 | 3802475 | 144297 | None | code55 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN | Nos | 3242.4 | 3242.4 | 1.0 | False | None | None | False | None | False | 3242.4 | 0 | 3802476 | 144297 | None | code56 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Nos | 3133.2 | 3133.2 | 2.0 | False | None | None | False | None | False | 6266.4 | 0 | 3802477 | 144297 | None | code57 | Gescom deposite | Nos | 1000.0 | 1000.0 | 1.0 | False | None | None | False | None | False | 1000.0 | 0 | 3802478 | 144297 | None | code58 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 4.15 | False | None | None | False | None | False | 1054.515 | 0 | 3802479 | 144297 | None | code59 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 0.82 | False | None | None | False | None | False | 5156.529 | 0 | 3802480 | 144297 | None | code60 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6971.11 | 6971.11 | 0.64 | False | None | None | False | None | False | 4461.5104 | 0 | 3802481 | 144297 | None | code61 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11286.56 | 11286.56 | 0.16 | False | None | None | False | None | False | 1805.8496 | 0 | 3802482 | 144297 | None | code62 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess | Cum | 12214.76 | 12214.76 | 0.4 | False | None | None | False | None | False | 4885.904 | 0 | 3802483 | 144297 | None | code63 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess | Cum | 11496.24 | 11496.24 | 1.22 | False | None | None | False | None | False | 14025.4128 | 0 | 3802484 | 144297 | None | code64 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings | Kgs | 93929.85 | 93929.85 | 0.16 | False | None | None | False | None | False | 15028.776 | 0 | 3802485 | 144297 | None | code65 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 2.13 | False | None | None | False | None | False | 17822.6685 | 0 | 3802486 | 144297 | None | code66 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 3.18 | False | None | None | False | None | False | 888.174 | 0 | 3802487 | 144297 | None | code67 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 28.32 | False | None | None | False | None | False | 7166.376 | 0 | 3802488 | 144297 | None | code68 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 29.21 | False | None | None | False | None | False | 4201.8585 | 0 | 3802489 | 144297 | None | code69 | Supply and Installation of Slide Ladder (Preschool Kit) Virgin Polycarbonate and Multi curve configuration | Each | 13685.0 | 13685.0 | 2.0 | False | None | None | False | None | False | 27370.0 | 0 | 3802490 | 144297 | None | code70 | Supply of NPS Blow moulding Indoor Fun See Saw | Each | 12380.0 | 12380.0 | 4.0 | False | None | None | False | None | False | 49520.0 | 0 | 3802491 | 144297 | None | code71 | Supply of Blow moulding Indoor Fun See Saw | Each | 2600.0 | 2600.0 | 4.0 | False | None | None | False | None | False | 10400.0 | 0 | 3802492 | 144297 | None | code72 | Supply of Swings for Preschool seat mede up of Virgin Polyethylene and frame materialCRC pipe of 25 mm dia. with wall
thickness of 20 gauge | Each | 22299.0 | 22299.0 | 1.0 | False | None | None | False | None | False | 22299.0 | 0 |
|