3813579 | 144811 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (UNI S.R.page NO:8, Item No-1.14.1 (Volume-1) | Cum | 107.1 | 107.1 | 71.7 | False | None | None | False | None | False | 7679.07 | 0 |
3813580 | 144811 | None | 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering,including cost of all materials and labour with all lead and lift complete as per specifications.S.R.page 11 item 1.23 (Volume-1) | Cum | 2816.1 | 2816.1 | 4.61 | False | None | None | False | None | False | 12982.221 | 0 |
3813581 | 144811 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.(S.R.page 15 item 2.1.3(Volume-3) | Cum | 6288.45 | 6288.45 | 12.95 | False | None | None | False | None | False | 81435.4275 | 0 |
3813582 | 144811 | None | 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.(S.R.page 15 item 2.1.4(Volume-3) | Cum | 6527.85 | 6527.85 | 9.25 | False | None | None | False | None | False | 60382.6125 | 0 |
3813583 | 144811 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.S.R.page 7 Item Nos 1.9 (Volume-1) | Cum | 279.3 | 279.3 | 21.51 | False | None | None | False | None | False | 6007.743 | 0 |
3813584 | 144811 | None | 1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.S.R.page 7 Item Nos 1.11 (Volume-1) | Cum | 454.65 | 454.65 | 29.4 | False | None | None | False | None | False | 13366.71 | 0 |
3813585 | 144811 | None | 2.2.2 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with 20% partial replacement with Recycled concrete aggregate (RCA)(S.R.page 15 item 2.2.2 (Volume-1) & Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding- for Plinth Beams of Buildings ( additional percentage to be added to the finished rates of concrete-8%)(type of material to be used is steel centering.) (PWD SR 2023-24 ( Vol-1 P.No.111/1a) | Cum | 7085.23 | 7085.23 | 9.22 | False | None | None | False | None | False | 65325.8206 | 0 |
3813586 | 144811 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(SR Page 9 iteam 5.4 (Volume-2) | Cum | 6708.45 | 6708.45 | 40.68 | False | None | None | False | None | False | 272899.746 | 0 |
3813587 | 144811 | None | 8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(S.R Page no 41, item no 8.3.2 (V-II) | Sqm | 349.65 | 349.65 | 20.86 | False | None | None | False | None | False | 7293.699 | 0 |
3813588 | 144811 | None | 2.2.2 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with 20% partial replacement with Recycled concrete aggregate (RCA)(S.R.page 15 item 2.2.2 (Volume-1) & Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding- for Plinth Beams of Buildings ( additional percentage to be added to the finished rates of concrete-50%)(type of material to be used is steel centering.) (PWD SR 2023-24 ( Vol-1 P.No.111/2) | Cum | 9840.6 | 9840.6 | 4.8 | False | None | None | False | None | False | 47234.88 | 0 |
3813589 | 144811 | None | 9.4 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.(PWD SR 2023-24 P.No.59/9.4(Volume-2) | Cum | 6999.3 | 6999.3 | 9.18 | False | None | None | False | None | False | 64253.574 | 0 |
3813590 | 144811 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.page 16, item 2.5.1 (Volume-1) & Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding- for RCC Columns / Shaft (Slip Centering) ( additional percentage to be added to the finished rates of concrete-70%)(type of material to be used is steel centering.) (PWD SR 2023-24 ( Vol-1 P.No.111/9) | Cum | 11834.55 | 11834.55 | 3.17 | False | None | None | False | None | False | 37515.5235 | 0 |
3813591 | 144811 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.page 16, item 2.5.1 (Volume-1) & Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding- RCC Roof Slabs ( additional percentage to be added to the finished rates of concrete-50%)(type of material to be used is steel centering.) (PWD SR 2023-24 ( Vol-1 P.No.111/15) | Cum | 10442.25 | 10442.25 | 7.32 | False | None | None | False | None | False | 76437.27 | 0 |
3813592 | 144811 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.page 16, item 2.5.1 (Volume-1) & Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding- RCC Beams, Lintels & Troughs of Aqueducts ( additional percentage to be added to the finished rates of concrete-60%)(type of material to be used is steel centering.) (PWD SR 2023-24 ( Vol-1 P.No.111/14) | Cum | 11138.4 | 11138.4 | 3.75 | False | None | None | False | None | False | 41769.0 | 0 |
3813593 | 144811 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (S.R Page no 18, item no 2.11a (Volume-1) | Tonne | 93929.85 | 93929.85 | 3.13 | False | None | None | False | None | False | 294000.4305 | 0 |
3813594 | 144811 | None | 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.( SR 2023-24(Page.14/Item No.6.8) | Cum | 8367.45 | 8367.45 | 52.37 | False | None | None | False | None | False | 438203.3565 | 0 |
3813595 | 144811 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.page 16, item 2.5.1 (Volume-1) & Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding- RCC Beams, Lintels & Troughs of Aqueducts ( additional percentage to be added to the finished rates of concrete-60%)(type of material to be used is steel centering.) (PWD SR 2023-24 ( Vol-1 P.No.111/14) | Cum | 11138.4 | 11138.4 | 2.4 | False | None | None | False | None | False | 26732.16 | 0 |
3813596 | 144811 | None | 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(S.R Page no 43, item no 8.10 (V-II) | Sqm | 221.55 | 221.55 | 47.01 | False | None | None | False | None | False | 10415.0655 | 0 |
3813597 | 144811 | None | 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing andremoving scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(.S.R Page no 41, item no 8.4.2 (Volume-2) | Sqm | 327.6 | 327.6 | 246.06 | False | None | None | False | None | False | 80609.256 | 0 |
3813598 | 144811 | None | 8.6.2 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(S.R Page no 42, item no 8.6.2 (V-II) | Sqm | 450.45 | 450.45 | 264.71 | False | None | None | False | None | False | 119238.6195 | 0 |
3813599 | 144811 | None | 8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.(S.R Page no 50 ,item no 8.54.2 (Volume-2) | Sqm | 115.5 | 115.5 | 61.02 | False | None | None | False | None | False | 7047.81 | 0 |
3813600 | 144811 | None | 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. S.R.page No-46, Item No-8.30 (Volume-2) | Sqm | 182.7 | 182.7 | 264.71 | False | None | None | False | None | False | 48362.517 | 0 |
3813601 | 144811 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(PWD SR 2023-24(P.No.105/12.60) (Volume-2) | No | 1104.6 | 1104.6 | 6.0 | False | None | None | False | None | False | 6627.6 | 0 |
3813602 | 144811 | None | 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.(PWD SR 2023-24(P.No.105/12.62) (Volume-2) | No | 248.85 | 248.85 | 12.0 | False | None | None | False | None | False | 2986.2 | 0 |
3813603 | 144811 | None | 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete(PWD SR 2023-24(P.No.105/12.63) (Volume-2) | No | 136.5 | 136.5 | 12.0 | False | None | None | False | None | False | 1638.0 | 0 |
3813604 | 144811 | None | 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms(PWD SR 2023-24(P.No.105/12.64) (Volume-2) | No | 57.75 | 57.75 | 12.0 | False | None | None | False | None | False | 693.0 | 0 |
3813605 | 144811 | None | 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x85x5.5 mm (heavy type)(PWD SR 2023-24(P.No.107/12.75.1) (Volume-2) | No | 288.75 | 288.75 | 36.0 | False | None | None | False | None | False | 10395.0 | 0 |
3813606 | 144811 | None | 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Fastener with threaded dia 12 mm(PWD SR 2023-24(P.No.69/10.6.3) (Volume-2) | Each | 63.0 | 63.0 | 36.0 | False | None | None | False | None | False | 2268.0 | 0 |
3813607 | 144811 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minorT&Ps shall not be made) (S.R.page No-109 ,item No- 12.85 (Volume-2) | Sqm | 6004.95 | 6004.95 | 7.56 | False | None | None | False | None | False | 45397.422 | 0 |
3813608 | 144811 | None | 12.96 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame S.R.page No-112, Item No-12.96 (Volume-2) | m | 675.15 | 675.15 | 13.2 | False | None | None | False | None | False | 8911.98 | 0 |
3813609 | 144811 | None | 12.97.2 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35mm thick S.R.page No-112, Item No-12.97.2 (Volume-2) | Sqm | 3816.75 | 3816.75 | 15.12 | False | None | None | False | None | False | 57709.26 | 0 |
3813610 | 144811 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or roundbars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (S.R.page No.86, Item 11.34 A (Volume-2) | Kg | 176.4 | 176.4 | 94.5 | False | None | None | False | None | False | 16669.8 | 0 |
3813611 | 144811 | None | 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24(P.No.47/8.33.3) (Volume-2) | Sqm | 145.95 | 145.95 | 3.78 | False | None | None | False | None | False | 551.691 | 0 |
3813612 | 144811 | None | 9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (S.R Page no 60, Item no 9.9 (V-II) | Sqm | 1129.8 | 1129.8 | 39.21 | False | None | None | False | None | False | 44299.458 | 0 |
3813613 | 144811 | None | 9.17.4 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1000x1000 mm (S.R Page no 61, Item no 9.17.4 (V-II) | Sqm | 1957.2 | 1957.2 | 220.02 | False | None | None | False | None | False | 430623.144 | 0 |
3813614 | 144811 | None | 9.6.1 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)Light shade pigment using white cement (S.R Page no 59, Item no 9.6.1 (V-II) | Sqm | 1332.45 | 1332.45 | 21.6 | False | None | None | False | None | False | 28780.92 | 0 |
3813615 | 144811 | None | 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (S.R Page no 149, item no 15.1 (V-II) | Sqm | 857.85 | 857.85 | 61.02 | False | None | None | False | None | False | 52346.007 | 0 |
3813616 | 144811 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(S.R Page No-85 I,.No.11.28(Volume-2) | Kg | 593.25 | 593.25 | 197.8 | False | None | None | False | None | False | 117344.85 | 0 |
3813617 | 144811 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. S.R.page No.123, Item 13.34 (Volume-2) | l | 9.45 | 9.45 | 4000.0 | False | None | None | False | None | False | 37800.0 | 0 |
3813618 | 144811 | None | 13.14 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. S.R Page No-117 I,.No.13.14 (Volume-2) | No | 888.3 | 888.3 | 12.0 | False | None | None | False | None | False | 10659.6 | 0 |
3813619 | 144811 | None | 13.4.1 | Providing and fixing Brass full way valve gate with C.I. wheel of approved qualitya. 25mm.dia.. (screwed end) :Page No-115,Item No-13.4.1 (Volume-2) | No | 576.45 | 576.45 | 4.0 | False | None | None | False | None | False | 2305.8 | 0 |
3813620 | 144811 | None | 13.6.3.1 | Providing and fixing in position below given nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments specification.Page No-116,Item No-13.6.3.1 (Volume-2) | Each | 1008.0 | 1008.0 | 4.0 | False | None | None | False | None | False | 4032.0 | 0 |
3813621 | 144811 | None | 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid SR page no-131, Item No-14.2.1 (Volume-2) | Each | 5079.9 | 5079.9 | 6.0 | False | None | None | False | None | False | 30479.4 | 0 |
3813622 | 144811 | None | 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (SR page no-132, Item No-14.7.1 (Volume-2) | Each | 3236.1 | 3236.1 | 6.0 | False | None | None | False | None | False | 19416.6 | 0 |
3813623 | 144811 | None | 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. SR page no-136, Item No-14.31 (Volume-2) | Each | 1281.0 | 1281.0 | 6.0 | False | None | None | False | None | False | 7686.0 | 0 |
3813624 | 144811 | None | 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. SR page no-137, Item No-14.40.2 (Volume-2) | Unit | 520.8 | 520.8 | 6.0 | False | None | None | False | None | False | 3124.8 | 0 |
3813625 | 144811 | None | 13.24 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 g (SR page no-121, Item No-13.24 (Volume-2) | Nos | 174.3 | 174.3 | 6.0 | False | None | None | False | None | False | 1045.8 | 0 |
3813626 | 144811 | None | 14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. SR page no-135, Item No-14.22A (Volume-2) | Nos | 850.5 | 850.5 | 6.0 | False | None | None | False | None | False | 5103.0 | 0 |
3813627 | 144811 | None | 13.2.2 | Providing and fixing in position brass bib cock of approved quality of as per dia nominal bore including cost of all materials,labour and HOM of equipments with all leads complete as per specifications. b. 20mm Nominal Bore Page No-117,Item No-13.2.2 (Volume-2) | Nos | 320.25 | 320.25 | 6.0 | False | None | None | False | None | False | 1921.5 | 0 |
3813628 | 144811 | None | 13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. Page No-121,Item No-13.26 (Volume-2) | Nos | 105.0 | 105.0 | 6.0 | False | None | None | False | None | False | 630.0 | 0 |
3813629 | 144811 | None | 13.33.3 | Providing & fixing Chorinated Poly Venyl(CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete.(External work and Burried).25mm.dia.. Page No-122,Item No-13.33.3 (Volume-2) | m | 310.8 | 310.8 | 60.0 | False | None | None | False | None | False | 18648.0 | 0 |
3813630 | 144811 | None | 13.33.4 | Providing & fixing Chorinated Poly Venyl(CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete.(External work and Burried). 32mm.dia.. Page No-122 ,Item No-13.33.4 (Volume-2) | m | 390.6 | 390.6 | 40.0 | False | None | None | False | None | False | 15624.0 | 0 |
3813631 | 144811 | None | 10.1.7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:110mm dia BWSSB-SR-2023-24 SR Page No-113 ,Item No-10.1.5 & 10.1.7(Volume-5) | m | 431.55 | 431.55 | 60.0 | False | None | None | False | None | False | 25893.0 | 0 |
3813632 | 144811 | None | 13.41 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :*100 mm inlet and 100 mm outlet* Sand Cast Iron S&S as per IS:1729 Page No-124,Item No-13.41(Volume-2) | Each | 1461.6 | 1461.6 | 6.0 | False | None | None | False | None | False | 8769.6 | 0 |
3813633 | 144811 | None | 13.22.1.2 | Providing and fixing PTMT grating of approved quality and colour. a. 125mm dia. Page No-120,Item No-13.22.1.2 (Volume-2) | Nos. | 43.05 | 43.05 | 6.0 | False | None | None | False | None | False | 258.3 | 0 |
3813634 | 144811 | None | 20.40 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in- charge. Page No-201,Item No-20.40 (Volume-2) | Each | 81.9 | 81.9 | 6.0 | False | None | None | False | None | False | 491.4 | 0 |
3813635 | 144811 | None | 16.8 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.BWSSB-2023-24 SR Page No-191,Item No-16.8, (Volume-5) | Nos. | 5030.55 | 5030.55 | 4.0 | False | None | None | False | None | False | 20122.2 | 0 |
3813636 | 144811 | None | 1.6.1 | Digging Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. 1.6.1) In all kinds of soils. Depth upto 1.50m item no.1.6.1 page no. 6 vol 1 (labour charges) PWD civil SR 2023-24 Sl No Item No 1.6.1. PWD Civil SR vol 1 page no 6 | Nos | 508.2 | 508.2 | 39.0 | False | None | None | False | None | False | 19819.8 | 0 |
3813637 | 144811 | None | 25a | Earthing 25.a) GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
25.a) Transformer grounding | Nos | 1815.45 | 1815.45 | 2.0 | False | None | None | False | None | False | 3630.9 | 0 |
3813638 | 144811 | None | 25a | Earthing 25.a) GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
25.a) Transformer grounding Hescom SR 2023-24 Item code 25.a (Labour Cost) | Nos | 996.45 | 996.45 | 2.0 | False | None | None | False | None | False | 1992.9 | 0 |
3813639 | 144811 | None | 1.6.1 | Digging of Pit 1.6.1 ) Digging of Pit for providing GI Pipe type Earthing Hescom SR 2023-24 Item code 25.a (Labour Cost) | Km | 796.95 | 796.95 | 2.0 | False | None | None | False | None | False | 1593.9 | 0 |
3813640 | 144811 | None | 32.05 | UG Cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
32.04) 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) Hescom SR 2023-24 Item code 32.05 (Material Cost) | Km | 92838.9 | 92838.9 | 0.15 | False | None | None | False | None | False | 13925.835 | 0 |
3813641 | 144811 | None | 21.05 | UG Cable Labour Charges Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 21.05) 2.5 to 25 Sqmm ESCOMs SR 2023-24 Item code 21.05 (Labour Cost) | m | 21930.3 | 21930.3 | 0.15 | False | None | None | False | None | False | 3289.545 | 0 |
3813642 | 144811 | None | 1.2.1 | Mains Pipe. Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick PWD Ele SR 2023-24 Page No.1 Item code 1.2.1 | m | 69.3 | 69.3 | 140.0 | False | None | None | False | None | False | 9702.0 | 0 |
3813643 | 144811 | None | 2.2.1 | Mains Pipe. Points Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.
complete for each outlet. 2.2.1) Short point upto 3Mtr from tapping point to out let via switch PWD Ele SR 2023-24 Page No.4 Item code 2.2.1 | Point | 282.45 | 282.45 | 12.0 | False | None | None | False | None | False | 3389.4 | 0 |
3813644 | 144811 | None | 2.2.2 | Points
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.2) Medium point above 3Mtr upto 6Mtr from tapping point to) PWD Ele SR 2023-24 Page No.4 Item code 2.2.2 | Point | 397.95 | 397.95 | 6.0 | False | None | None | False | None | False | 2387.7 | 0 |
3813645 | 144811 | None | 2.3.2 | Wire: Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 2.3.2) 1.5 mm2 PWD Ele SR 2023-24 Page No.4 Item code 2.3.2 | Mtr | 27.3 | 27.3 | 100.0 | False | None | None | False | None | False | 2730.0 | 0 |
3813646 | 144811 | None | 2.3.2 | Wire: Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 2.3.3)2.5 mm2 PWD Ele SR 2023-24 Page No.4 Item code 2.3.2 | Mtr | 44.1 | 44.1 | 200.0 | False | None | None | False | None | False | 8820.0 | 0 |
3813647 | 144811 | None | 3.3.4 | PVC modular box: Supplying and fixing surface/flush mounting unbreakable PVC bmodular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,
Machine/NF screws etc., complete. 3.3.4) 6 Way PWD Ele SR 2023-24 Page No.7 Item code 3.3.4 | Nos | 181.65 | 181.65 | 6.0 | False | None | None | False | None | False | 1089.9 | 0 |
3813648 | 144811 | None | 3.5.4 | modular Switch Plate Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the
existing metal/PVC box. 3.5.4) 6 Module PWD Ele SR 2023-24 Page No.7 Item code 3.5.4 | Nos | 245.7 | 245.7 | 6.0 | False | None | None | False | None | False | 1474.2 | 0 |
3813649 | 144811 | None | 3.6.1 | Modular switch Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1) 6Amps one way. PWD Ele SR 2023-24 Page No.8 Item code 3.6.1 | Nos | 107.1 | 107.1 | 24.0 | False | None | None | False | None | False | 2570.4 | 0 |
3813650 | 144811 | None | 3.6.4 | Batten Holder Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 3.14.7) 6A Batten Holder PWD Ele SR 2023-24 Page No.9 Item code 3.6.4 | Nos | 77.7 | 77.7 | 18.0 | False | None | None | False | None | False | 1398.6 | 0 |
3813651 | 144811 | None | 11.11.4 | LED Bulb Supplying & fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
11.11.4) 9W, 6500KPWD Ele SR 2023-24 Page No.42 Item code 11.11.4 | Nos | 161.7 | 161.7 | 12.0 | False | None | None | False | None | False | 1940.4 | 0 |
3813652 | 144811 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply PWD Ele SR 2023-24 Page No.29 Item code 6.1 | Nos | 1566.6 | 1566.6 | 6.0 | False | None | None | False | None | False | 9399.6 | 0 |
3813653 | 144811 | None | 13.14 | Fan Fixing Charges Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire PWD Ele SR 2023-24 Page No.56 Item code 13.14 | Nos | 516.6 | 516.6 | 6.0 | False | None | None | False | None | False | 3099.6 | 0 |
3813654 | 144811 | None | 5.7.2 | Fuses. Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 5.7.2) 32 A PWD Ele SR 2023-24 Page No.56 Item code 5.7.2 | Nos | 253.05 | 253.05 | 2.0 | False | None | None | False | None | False | 506.1 | 0 |
3813655 | 144811 | None | 5.18.4 | MCB Switches. Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.4) 6-32 Amps DP PWD Ele SR 2023-24 Page No.56 Item code 5.18.4 | Nos | 775.95 | 775.95 | 6.0 | False | None | None | False | None | False | 4655.7 | 0 |
3813656 | 144811 | None | 1.2.3 | PVC Pipe Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1.2.3) 32 mm dia 2.5 mm thick PWD Ele SR 2023-24 Page No.2 Item code1.2.3 | Mtr | 108.15 | 108.15 | 140.0 | False | None | None | False | None | False | 15141.0 | 0 |
3813657 | 144811 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium
housing body for optimal thermal dissipation. Lamp compartment
comprising of anti glare clear diffuser with Injection moulded
polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66optical and electrical compartment & impact resistance of completeluminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min5KV along with Over voltage/ Overload, short circuit/ miss-wiringprotection. Compatible for pole mounting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED ficiency greater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.8.2 ) LED Streetlight 40W SR 2023-24 Page No.55 Item code 11.8.2 | Nos | 4225.2 | 4225.2 | 2.0 | False | None | None | False | None | False | 8450.4 | 0 |
3813658 | 144811 | None | 13.1.1 | Supplying and Fixing of mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.13.1.1 ) Using 25mm dia G.I.Pipe PWD Ele SR 2023-24 Page No.55 Item code 13.1.1 | Nos | 1026.9 | 1026.9 | 2.0 | False | None | None | False | None | False | 2053.8 | 0 |
3813659 | 144811 | None | 5.6.2 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 5.6.2) 10" x 8" x 1.5" PWD Ele SR 2023-24 Page No.13 Item code 5.6.2 | Each | 107.1 | 107.1 | 8.0 | False | None | None | False | None | False | 856.8 | 0 |