createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724056290077
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd502200.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-08-2024 17:00:00
tenderQueryClose21-08-2024 15:00:00
technicalBidOpen30-08-2024 11:35:00
publishedDate19-08-2024 21:01:06
publishedByPostKKRTC_EE_HOFF_BLR
publishedByUserKPE10109 - M ERESH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate23-08-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM.Eresh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08392294828
mobileNumber9972039797
tenderSupplierListNone
tenderSchedule
createdTs1724056290107
version6
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/BD/WORK_INDENT102
titleConstruction of New Bus Station at Itagi (Kukanur Taluk) (Call-3)
descriptionConstruction of New Bus Station at Itagi (Kukanur Taluk) (Call-3)
categoryWORKS
categoryTextWorks
ecv40000000.00
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5937
locationNameKKRTC Divisional Controller Office Bellari
provisionalAmount40000000.0
groupOverheadTotal6526030.48
fileNumber1004
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17240562900000NoneNoneBuildingsConstruction of New Bus Station at Itagi (Kukanur Taluk) (Call-3)33473969.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3808403144602Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) Depth exceeding 1.5 m, but not exceeding 3 m.In all kinds of soils Depth upto 3 mCum107.1107.11246.94FalseNoneNoneFalseNoneFalse133547.2740
3808404144602Nonecode02Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.15.1) In ordinary/soft rock without blasting upto 1.5 m depth.Cum381.15381.15175.63FalseNoneNoneFalseNoneFalse66941.37450
3808405144602Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.2213.37FalseNoneNoneFalseNoneFalse1268954.0640
3808406144602Nonecode04Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP- Vol-I (7/1.9)Cum279.3279.3528.7FalseNoneNoneFalseNoneFalse147665.910
3808407144602Nonecode05KSRB 2.3 Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP- Vol-I (7/1.10)Cum441.0441.0829.91FalseNoneNoneFalseNoneFalse365990.310
3808408144602Nonecode06Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6724.26724.210.48FalseNoneNoneFalseNoneFalse70469.6160
3808409144602Nonecode07Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.3) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated)Cum7185.027185.02161.9FalseNoneNoneFalseNoneFalse1163254.7380
3808410144602Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.2) M25Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12214.7612214.7682.07FalseNoneNoneFalseNoneFalse1002465.35320
3808411144602Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.2) M25Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10777.7310777.73301.15FalseNoneNoneFalseNoneFalse3245713.38950
3808412144602Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11496.2411496.2467.46FalseNoneNoneFalseNoneFalse775536.35040
3808413144602Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10418.4710418.471.32FalseNoneNoneFalseNoneFalse13752.38040
3808414144602Nonecode12Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (106/12.57.4) 35 mm thick Both side teakSqm4758.64758.614.8FalseNoneNoneFalseNoneFalse70427.280
3808415144602Nonecode13Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12)Cum130412.1130412.10.42FalseNoneNoneFalseNoneFalse54773.0820
3808416144602Nonecode14Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (105/12.54)Rmtr333.9333.974.1FalseNoneNoneFalseNoneFalse24741.990
3808417144602Nonecode15VOL II SRP 106/12.55.1 Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges (both side prelam)Sqm2484.32484.320.48FalseNoneNoneFalseNoneFalse50878.4640
3808418144602Nonecode16Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/11.34A)Kg176.4176.42375.35FalseNoneNoneFalseNoneFalse419011.740
3808419144602Nonecode17Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8)Cum8367.458367.45323.86FalseNoneNoneFalseNoneFalse2709882.3570
3808420144602Nonecode18Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1)Sqm309.75309.751747.46FalseNoneNoneFalseNoneFalse541275.7350
3808421144602Nonecode19Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.2)Sqm267.75267.751003.88FalseNoneNoneFalseNoneFalse268788.870
3808422144602Nonecode20Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.35.1.2/86)Kg513.45513.45170.61FalseNoneNoneFalseNoneFalse87599.70450
3808423144602Nonecode21Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.37.2/82)Sqm1229.551229.5529.88FalseNoneNoneFalseNoneFalse36738.9540
3808424144602Nonecode22Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (83/11.28)Kg593.25593.25160.1FalseNoneNoneFalseNoneFalse94979.3250
3808425144602Nonecode23Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.SRP- Vol-II (50/8.51)Sqm105.0105.01643.78FalseNoneNoneFalseNoneFalse172596.90
3808426144602Nonecode24Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification.SRP- Vol-II (72/10.19)Sqm3787.353787.3567.24FalseNoneNoneFalseNoneFalse254661.4140
3808427144602Nonecode25Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately). SRP- Vol-II (62/9.22.2)Size of Tile 600x600 mmSqm1392.31392.350.95FalseNoneNoneFalseNoneFalse70937.6850
3808428144602Nonecode26Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.SRP- Vol-II (64/9.34)Sqm1622.251622.25173.68FalseNoneNoneFalseNoneFalse281752.380
3808429144602Nonecode27Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar,labour, curing etc., complete. SRP- Vol-II (72/10.18)Sqm3526.953526.9540.16FalseNoneNoneFalseNoneFalse141642.3120
3808430144602Nonecode28Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (69/10.2)Rmtr344.4344.465.5FalseNoneNoneFalseNoneFalse22558.20
3808431144602Nonecode29Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-I (18/2.11/a)Kg93.9293.9271885.02FalseNoneNoneFalseNoneFalse6751441.07840
3808432144602Nonecode30Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (75/11.1)Kg111.3111.34214.38FalseNoneNoneFalseNoneFalse469060.4940
3808433144602Nonecode31Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. SRP- Vol-II (26/7.38)Sqm596.4596.4154.85FalseNoneNoneFalseNoneFalse92352.540
3808434144602Nonecode32Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete SRP- Vol-II (71/10.15.1)Sqm4188.454188.4545.36FalseNoneNoneFalseNoneFalse189988.0920
3808435144602Nonecode33Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ eams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval fromstructural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts,washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glasspanel inside the SS channel shall be measured.SRP- Vol-II (160/18.7)Sqm8349.68349.619.44FalseNoneNoneFalseNoneFalse162316.2240
3808436144602Nonecode34KSRB 7.15 Providing , fabricating, assembling and fixing in position anodized aluminum partions using aluminium section of mat finish or glassy finish in combination of plain grove, single groove, single grove and double grove as per requirements for the frames of overall size 63.5mmx38.1mm. with thickness of 2 mm having section weight, plain sections. 1.054 kg/m, single grove thickness 1.95mm section weight. 1.094kg/m and bottom member 114.3mm x 44.45mm thickness 3.18mm weight 2.646 kg/m aluminium louvers section of size 36.5mmx34.93mm 1.45mm thick section weight 0.429kg/m bottom prortion provided with 12mm thick prelaminated sheet both sides of approved portion viz., 0.9m to 2.13m and top panel with louvers sections; the glass and panels fitted wtih glazing clips of 19mm x 17.3mm of thickness 0.9mm weight 0.13 and top panel with louvers sections; the glass and panels fitted with glazing clips of 19mmx 17.3mm of thickness 0.9mm weight 0.124kg/m aluminium setions anodised 12 to 15 microns, sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non adherence of mortars or any other sticky materials ; vertical members embedded in the flooring by making suitable sized holes and fixing with cement mortar, with necesary opening for fixing of door of standard size ( excluding cost of door ) all the frame throughly cleaned, free from rust , scale of dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specification SRP 38/7.15.2 ( Powder Coated )Sqm3432.03432.06.48FalseNoneNoneFalseNoneFalse22239.360
3808437144602Nonecode35Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 16.9/191Each5030.555030.556.0FalseNoneNoneFalseNoneFalse30183.30
3808438144602Nonecode36Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. SRP- Vol-V 94/9.1.4Rmtr492.45492.45340.0FalseNoneNoneFalseNoneFalse167433.00
3808439144602Nonecode37Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 187/16.1.2Rmtr610.05610.05100.0FalseNoneNoneFalseNoneFalse61005.00
3808440144602Nonecode38VOL II SRP 46/8.33.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.9144.9120.0FalseNoneNoneFalseNoneFalse17388.00
3808441144602Nonecode39Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (45/8.25)Sqm143.85143.851643.78FalseNoneNoneFalseNoneFalse236457.7530
3808442144602Nonecode40Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28)Sqm93.4593.451704.3FalseNoneNoneFalseNoneFalse159266.8350
3808443144602Nonecode41Providing and placing on terrace ( at all floor levels) polyethylene water storage tanks,IS : 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP- Vol-II (12/13.34)Ltr9.459.456000.0FalseNoneNoneFalseNoneFalse56700.00
3808444144602Nonecode42Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.5) 40 mmMtr500.85500.85220.0FalseNoneNoneFalseNoneFalse110187.00
3808445144602Nonecode43Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.3) 25 mmMtr310.8310.8170.0FalseNoneNoneFalseNoneFalse52836.00
3808446144602Nonecode44Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.2) 20 mmMtr227.85227.85150.0FalseNoneNoneFalseNoneFalse34177.50
3808447144602Nonecode45Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.1) 15 mmMtr174.3174.3130.0FalseNoneNoneFalseNoneFalse22659.00
3808448144602Nonecode46White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (133/14.7.7)Nos2203.952203.955.0FalseNoneNoneFalseNoneFalse11019.750
3808449144602Nonecode47White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. SRP- Vol-II (126/14.13.2)Nos2447.552447.557.0FalseNoneNoneFalseNoneFalse17132.850
3808450144602Nonecode48Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : SRP- Vol-II (128/14.32.3)Unit1119.31119.35.0FalseNoneNoneFalseNoneFalse5596.50
3808451144602Nonecode49VOL II 124/14.5.1 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Each9074.19074.19.0FalseNoneNoneFalseNoneFalse81666.90
3808452144602Nonecode50Providing and fixing white vitreous china water closet squatting pan (Indian type) Long pattern W.C. pan of size 580 mm SRP- Vol-II (134/14.13.1)Each1499.41499.44.0FalseNoneNoneFalseNoneFalse5997.60
3808453144602Nonecode51Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1:2:4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2Each285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3808454144602Nonecode52Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP- Vol-II (117/13.5.1)Nos310.8310.810.0FalseNoneNoneFalseNoneFalse3108.00
3808455144602Nonecode53Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3)Nos737.1737.14.0FalseNoneNoneFalseNoneFalse2948.40
3808456144602Nonecode54Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP- Vol-II (117/13.3.1)Nos313.95313.9520.0FalseNoneNoneFalseNoneFalse6279.00
3808457144602Nonecode55Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (76/11.6.3)Sqm2388.752388.75111.63FalseNoneNoneFalseNoneFalse266656.16250
3808458144602Nonecode56Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11)Sqm933.45933.4559.64FalseNoneNoneFalseNoneFalse55670.9580
3808459144602Nonecode57Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38)Sqm1461.61461.6138.43FalseNoneNoneFalseNoneFalse202329.2880
3808460144602Nonecode58Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.SRP- Vol-II (65/9.40)Sqm978.6978.648.28FalseNoneNoneFalseNoneFalse47246.8080
3808461144602Nonecode59Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.SRP- Vol-II (63/9.25)Sqm840.0840.0600.0FalseNoneNoneFalseNoneFalse504000.00
3808462144602Nonecode60Supplying and fixing MS Chairs & 3 seater of approved qulaity including fixing in flooring drilling to the suitable holes grouting complete as per direction of Engineer in charge of work complete as per specifications with all lead and lift. (Approved rate)Nos5500.05500.050.0FalseNoneNoneFalseNoneFalse275000.00
3808463144602Nonecode61Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground SRP- Vol-I (A-45/50)Hour1417.51417.519.0FalseNoneNoneFalseNoneFalse26932.50
3808464144602Nonecode62Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SRP- Vol-I (7/1.8)Cum497.7497.71350.0FalseNoneNoneFalseNoneFalse671895.00
3808465144602Nonecode63Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. SRP- Vol-III (24/4.27)Cum2686.952686.95187.5FalseNoneNoneFalseNoneFalse503803.1250
3808466144602Nonecode64Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.SRP- Vol-III (43/6.1)complete in C.C. 1:6:12 prop )Cum5166.05166.0187.5FalseNoneNoneFalseNoneFalse968625.00
3808467144602Nonecode65Construction of M40 grade un-reinforced,Cement Concrete Pavement with OPC/PPC/PSC dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing SRP- Vol-III (43/6.2)Cum9514.059514.05300.0FalseNoneNoneFalseNoneFalse2854215.00
3808468144602Nonecode66Supplying, fitting and placing un-coated Mild steel reinforcement complete in foundation as per drawing and technical specification. SRP- Vol-I (18/2.12)Kg77.477.416500.0FalseNoneNoneFalseNoneFalse1277100.00
3808469144602Nonecode67Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.7)Rmtr431.55431.5590.0FalseNoneNoneFalseNoneFalse38839.50
3808470144602Nonecode68Korean truff (Bijapur BS Approved Rate)Sqm175.0175.040.0FalseNoneNoneFalseNoneFalse7000.00
3808471144602Nonecode69Providing & supplying of plants from forest department of plants size 14" x 20" with supporting guard stick including transportation loading unloading placeing the plants in pits of 1 Mtr x 1 Mtr x 1 Mtr of size pits and refiling of required quantity and watering etc., complete.Each100.0100.040.0FalseNoneNoneFalseNoneFalse4000.00
3808472144602Nonecode70Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2)Sqm292.95292.95700.42FalseNoneNoneFalseNoneFalse205188.0390
3808473144602Nonecode71Providing patti allround compound wall etc, with CM 1:3 and finished as per design and specification including scafolding etc, complete. Patti 10cm wide and 10 mm thick.Rmtr11.8811.88389.12FalseNoneNoneFalseNoneFalse4622.74560
3808474144602Nonecode72Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30)Sqm5594.45594.48.82FalseNoneNoneFalseNoneFalse49342.6080
3808475144602Nonecode73Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. SRP- Vol-II (123/14.3.2) W.C. pan with ISI marked black solid plastic seat and lid.Each6095.256095.255.0FalseNoneNoneFalseNoneFalse30476.250
3808476144602Nonecode74Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7129.467129.4612.48FalseNoneNoneFalseNoneFalse88975.66080
3808477144602Nonecode75Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.254.52FalseNoneNoneFalseNoneFalse47198.970
3808478144602Nonecode76Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.414.06FalseNoneNoneFalseNoneFalse156605.9040
3808479144602Nonecode77Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 0 to 50 m SRP- Vol-V (139/12.2.1)Rmtr324.45324.4560.0FalseNoneNoneFalseNoneFalse19467.00
3808480144602Nonecode78Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 50 to 100 m SRP- Vol-V (139/12.2.2)Rmtr406.35406.3530.0FalseNoneNoneFalseNoneFalse12190.50
3808481144602Nonecode79Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 100 to 150 m SRP- Vol-V (139/12.2.3)Rmtr432.6432.660.0FalseNoneNoneFalseNoneFalse25956.00
3808482144602Nonecode80Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.9)Rmtr628.95628.9520.0FalseNoneNoneFalseNoneFalse12579.00
3808483144602Nonecode81Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 113/10.1.8)Rmtr613.2613.240.0FalseNoneNoneFalseNoneFalse24528.00
3808484144602Nonecode82Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. 5 O050A Cleaning of borewells including yield.VOL-V 139/12.2Each5288.05288.01.0FalseNoneNoneFalseNoneFalse5288.00
3808485144602Nonecode83SRP:1.2 Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick 1.2.2Mtr81.981.9500.0FalseNoneNoneFalseNoneFalse40950.00
3808486144602Nonecode84SRP: 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr82.9582.95300.0FalseNoneNoneFalseNoneFalse24885.00
3808487144602Nonecode851.1.2 Open Conduit System:Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr85.0585.0530.0FalseNoneNoneFalseNoneFalse2551.50
3808488144602Nonecode86SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm 2.3.2Mtr27.327.32500.0FalseNoneNoneFalseNoneFalse68250.00
3808489144602Nonecode87SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm (P6/2.3.3)Mtr44.144.11500.0FalseNoneNoneFalseNoneFalse66150.00
3808490144602Nonecode88SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4sqmm (P6/2.3.4)Mtr66.1566.15800.0FalseNoneNoneFalseNoneFalse52920.00
3808491144602Nonecode89SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6sqmm (P6/2.3.5)Mtr96.696.660.0FalseNoneNoneFalseNoneFalse5796.00
3808492144602Nonecode90SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10sqmm (P6/2.3.6)Mtr175.35175.3580.0FalseNoneNoneFalseNoneFalse14028.00
3808493144602Nonecode91SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16sqmm(P6/2.3.7)Mtr333.9333.990.0FalseNoneNoneFalseNoneFalse30051.00
3808494144602Nonecode92SRP:2.2.1 Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNo282.45282.4530.0FalseNoneNoneFalseNoneFalse8473.50
3808495144602Nonecode93SRP:2.2.1 Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2)No397.95397.9530.0FalseNoneNoneFalseNoneFalse11938.50
3808496144602Nonecode94SRP:2.2.1 Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3)No582.75582.7550.0FalseNoneNoneFalseNoneFalse29137.50
3808497144602Nonecode95Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-2Way 3.4.1No144.9144.930.0FalseNoneNoneFalseNoneFalse4347.00
3808498144602Nonecode96Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4way (P15/3.4.3)No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3808499144602Nonecode97Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 way (P15/3.4.4)No231.0231.012.0FalseNoneNoneFalseNoneFalse2772.00
3808500144602Nonecode98Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 way (P15/3.4.6)No334.95334.9518.0FalseNoneNoneFalseNoneFalse6029.10
3808501144602Nonecode99Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 18 way (P15/3.4.8)No425.25425.254.0FalseNoneNoneFalseNoneFalse1701.00
3808502144602Nonecode100Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module 3.5.1No143.85143.8540.0FalseNoneNoneFalseNoneFalse5754.00
3808503144602Nonecode101Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4mod (P16/3.5.3)No183.75183.758.0FalseNoneNoneFalseNoneFalse1470.00
3808504144602Nonecode102Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module (P16/3.5.4)No245.7245.716.0FalseNoneNoneFalseNoneFalse3931.20
3808505144602Nonecode103Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (P16/3.5.6)No361.2361.222.0FalseNoneNoneFalseNoneFalse7946.40
3808506144602Nonecode104Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18 Module (P16/3.5.8)No479.85479.856.0FalseNoneNoneFalseNoneFalse2879.10
3808507144602Nonecode105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1No107.1107.1300.0FalseNoneNoneFalseNoneFalse32130.00
3808508144602Nonecode106Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3 way socket (P16/3.6.3)No179.55179.55150.0FalseNoneNoneFalseNoneFalse26932.50
3808509144602Nonecode107Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. modular stepped fan regulator (P16/3.6.4)No374.85374.8530.0FalseNoneNoneFalseNoneFalse11245.50
3808510144602Nonecode108Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch (P16/3.6.7)No189.0189.06.0FalseNoneNoneFalseNoneFalse1134.00
3808511144602Nonecode109Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal socket (P16/3.6.10)No247.8247.88.0FalseNoneNoneFalseNoneFalse1982.40
3808512144602Nonecode110Supplying and fixing Fan box with round hook (P3/1.13)No122.85122.8530.0FalseNoneNoneFalseNoneFalse3685.50
3808513144602Nonecode111Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2Mtr23.123.130.0FalseNoneNoneFalseNoneFalse693.00
3808514144602Nonecode112Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fighting 1 x4'- 20/22 w 11.3.2No724.5724.550.0FalseNoneNoneFalseNoneFalse36225.00
3808515144602Nonecode11311.5.3 Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WNo1390.21390.215.0FalseNoneNoneFalseNoneFalse20853.00
3808516144602Nonecode114Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. Efficacy greater than100 lumen per watt, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should Less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' / 1' x 4' 34 -36watt 11.6.3No4780.654780.655.0FalseNoneNoneFalseNoneFalse23903.250
3808517144602Nonecode11511.8.4 Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo9303.09303.07.0FalseNoneNoneFalseNoneFalse65121.00
3808518144602Nonecode1166.3.1 Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.No3133.23133.230.0FalseNoneNoneFalseNoneFalse93996.00
3808519144602Nonecode1176.4.1 Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 10% RPM, Rated air delivery 210 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer WarrantyNo2810.852810.858.0FalseNoneNoneFalseNoneFalse22486.80
3808520144602Nonecode1186.2.1 Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm) 7.2.1No3117.453117.456.0FalseNoneNoneFalseNoneFalse18704.70
3808521144602Nonecode119Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders 13.7.1No128.1128.150.0FalseNoneNoneFalseNoneFalse6405.00
3808522144602Nonecode120Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe 13.2.3No1551.91551.96.0FalseNoneNoneFalseNoneFalse9311.40
3808523144602Nonecode1216.5.1 Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.No2616.62616.63.0FalseNoneNoneFalseNoneFalse7849.80
3808524144602Nonecode122Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.13.10No179.55179.5530.0FalseNoneNoneFalseNoneFalse5386.50
3808525144602Nonecode123Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.13.13No742.35742.358.0FalseNoneNoneFalseNoneFalse5938.80
3808526144602Nonecode124Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.1 6-32Amps SPNo435.75435.7530.0FalseNoneNoneFalseNoneFalse13072.50
3808527144602Nonecode125Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP. (5.18.4)No775.95775.9550.0FalseNoneNoneFalseNoneFalse38797.50
3808528144602Nonecode126Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps TPN. (5.18.7)No1802.851802.855.0FalseNoneNoneFalseNoneFalse9014.250
3808529144602Nonecode127Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN . (5.18.9)No3242.43242.45.0FalseNoneNoneFalseNoneFalse16212.00
3808530144602Nonecode12811.2.1 Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per watt, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should Less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Each654.15654.1510.0FalseNoneNoneFalseNoneFalse6541.50
3808531144602Nonecode12912.2.3 Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Each1249.51249.53.0FalseNoneNoneFalseNoneFalse3748.50
3808532144602Nonecode1308.1 Supplying and drawing UTP-CAT 6E LAN cable.Mtr39.939.9200.0FalseNoneNoneFalseNoneFalse7980.00
3808533144602Nonecode1318.4.6 Supplying & Fixing of switch mounting rack with power manager & Cable manager.24U with 650mm depthEach32955.332955.35.0FalseNoneNoneFalseNoneFalse164776.50
3808534144602Nonecode1328.9.10 Supplying fixing of Network Switches 24 port 10/100/1000 SwitchNo7785.757785.755.0FalseNoneNoneFalseNoneFalse38928.750
3808535144602Nonecode1338.10.1 Supplying & fixing of I/O socket with back boxNo514.5514.530.0FalseNoneNoneFalseNoneFalse15435.00
3808536144602Nonecode1346.8.5 Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.1.5 Ton capacityNo59172.7559172.754.0FalseNoneNoneFalseNoneFalse236691.00
3808537144602Nonecode1356.12 Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C.No3333.753333.754.0FalseNoneNoneFalseNoneFalse13335.00
3808538144602Nonecode1366.13.1 Supplying and installation of insulated refrigerant copper tubing of 5/8 and 3/8 with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. Leak testing oil and gas charging for additional piping length of tube.Mtr1626.451626.4512.0FalseNoneNoneFalseNoneFalse19517.40
3808539144602Nonecode1373.14.15 Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.16/6 Amps combined plug and socket with control switchEach228.9228.95.0FalseNoneNoneFalseNoneFalse1144.50
3808540144602Nonecode13810.1.5 40 kVA/32kW Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditionsNo587072.85587072.851.0FalseNoneNoneFalseNoneFalse587072.850
3808541144602Nonecode13910.2.2 40 to 50 KVASupply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage,....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.No74986.874986.81.0FalseNoneNoneFalseNoneFalse74986.80
3808542144602Nonecode14012.57 Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.6.2 old srNo4468.84468.84.0FalseNoneNoneFalseNoneFalse17875.20
3808543144602Nonecode141Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 5.15.11 160Amps 25kA.No14119.3514119.355.0FalseNoneNoneFalseNoneFalse70596.750
3808544144602Nonecode142Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.5.29No1496.251496.256.0FalseNoneNoneFalseNoneFalse8977.50
3808545144602Nonecode143Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No590.1590.115.0FalseNoneNoneFalseNoneFalse8851.50
3808546144602Nonecode144Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No540.75540.7512.0FalseNoneNoneFalseNoneFalse6489.00
3808547144602Nonecode145Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG 5.42.1Sq CM0.520.52100000.0FalseNoneNoneFalseNoneFalse52000.00
3808548144602Nonecode146Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips 5.40.1Mtr2588.252588.254.0FalseNoneNoneFalseNoneFalse10353.00
3808549144602Nonecode147Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm 5.41.1Mtr320.25320.2525.0FalseNoneNoneFalseNoneFalse8006.250
3808550144602Nonecode148Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia 6.1 old srNo3685.53685.515.0FalseNoneNoneFalseNoneFalse55282.50
3808551144602Nonecode149Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.6.2No4468.84468.815.0FalseNoneNoneFalseNoneFalse67032.00
3808552144602Nonecode150Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip 12.58.2Mtr86.186.160.0FalseNoneNoneFalseNoneFalse5166.00
3808553144602Nonecode151Gescom sr/11KV materials/134/18.01:LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018)Each23820.323820.32.0FalseNoneNoneFalseNoneFalse47640.60
3808554144602Nonecode152Gescom sr/11KV materials/207/32.11: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km187921.65187921.650.5FalseNoneNoneFalseNoneFalse93960.8250
3808555144602Nonecode153Gescom sr/11KV Labour/176/21.06: Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm32695.9532695.950.5FalseNoneNoneFalseNoneFalse16347.9750
3808556144602Nonecode154Vol I/1.14.1 Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)In soil (hard) 6.6.2Cum107.1107.1160.0FalseNoneNoneFalseNoneFalse17136.00
3808557144602Nonecode155Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.1No3.153.15220.0FalseNoneNoneFalseNoneFalse693.00
3808558144602Nonecode156Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 2.5 sqmm. (6.17.2)No4.24.2300.0FalseNoneNoneFalseNoneFalse1260.00
3808559144602Nonecode157Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 4.0 sqmm. (6.17.3)No4.24.2190.0FalseNoneNoneFalseNoneFalse798.00
3808560144602Nonecode158Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 6 sqmm. (6.17.4)No7.357.35120.0FalseNoneNoneFalseNoneFalse882.00
3808561144602Nonecode159Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10sqmm.(6.17.5)No8.48.432.0FalseNoneNoneFalseNoneFalse268.80
3808562144602Nonecode160Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 16 sqmm. (6.17.6)No13.0613.0615.0FalseNoneNoneFalseNoneFalse195.90
3808563144602Nonecode161Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 50 sqmm Long Barrel. (6.17.9)No63.063.020.0FalseNoneNoneFalseNoneFalse1260.00
3808564144602Nonecode162Vol V/9.1.4 Providing and fixing to wall, ceiling and floor, high density polyethylene pipes 6.00 kgf/sq.cm working pressure 110 mm outside diameter compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments & testing complete as per specificationsMtr492.45492.45250.0FalseNoneNoneFalseNoneFalse123112.50
3808565144602Nonecode163Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.5.33Each9780.759780.752.0FalseNoneNoneFalseNoneFalse19561.50
3808566144602Nonecode164Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs.5.39Each22722.022722.02.0FalseNoneNoneFalseNoneFalse45444.00
3808567144602Nonecode165VOl-6/KPTCL/P.No-158 Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedureCum1861.651861.653.0FalseNoneNoneFalseNoneFalse5584.950
3808568144602Nonecode166Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor.5.37Kvar504.0504.030.0FalseNoneNoneFalseNoneFalse15120.00
3808569144602Nonecode167Gescom sr/11KV materials/ 536/ 66.04: HDPE/PLB Pipe 50/42 mmKm89264.789264.70.14FalseNoneNoneFalseNoneFalse12497.0580
3808570144602Nonecode1685.13.1 Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.25 AmpsEach1354.51354.56.0FalseNoneNoneFalseNoneFalse8127.00
3808571144602Nonecode1695.16 Supplying and fixing of Shunt trip suitable for MCCB.CBCT.Mtr1788.151788.152.0FalseNoneNoneFalseNoneFalse3576.30
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17240562910000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17240562910000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17240562910000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17240562910000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17240562910000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17240563010000NoneNoneELIGIBILITYEstimated Rates inclusive of all taxes.None
17240563080000NoneNoneELIGIBILITYGST Shall be paid to the Tendered amount separately.None
17240563130000NoneNoneELIGIBILITYThe Government and the Contractor shall be bound to pay / refund of GST rates during the validity period of the contract to execute the work.None
17240563190000NoneNoneELIGIBILITYTerms and Conditions as per tender notificationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneUpload a Scanned copy of attested Valid contractors Registration Certificate as per Tender notification Eligibility CriteriaOthersRegistered Civil Prime Contractor in Karnataka
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of attested Valid contractors Registration Certificate as per Tender notification Eligibility Criteria
NoneNoneNoneNoneUpload a Scanned copy of minimum built-up area as per Tender notification Eligibility CriteriaOthersSingle work of RCC Frame Structure BUILDING with minimum built-up area
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of minimum built-up area as per Tender notification Eligibility Criteria
NoneNoneNoneNoneUpload a Scanned copy of work done certificate as per Tender notification Eligibility CriteriaOthersShould have successfully completed at least one work done certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of work done certificate as per Tender notification Eligibility Criteria
NoneNoneNoneNoneUpload a Scanned copy of work done certificate as per Tender notification Eligibility CriteriaOthersQuantities of work done certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of work done certificate as per Tender notification Eligibility Criteria
NoneNoneNoneNoneUpload a Scanned copy of audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per Tender notification Eligibility CriteriaOthersAnnual Financial Turnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per Tender notification Eligibility Criteria
NoneNoneNoneNoneUpload a Scanned copy of Liquid assets statement or availability of credit facilities letter of credit as per Tender notification Eligibility Criteria (Annexure-A)OthersQualify for award of this contract the Tenderer has to furnish Liquid assets statement
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Liquid assets statement or availability of credit facilities letter of credit as per Tender notification Eligibility Criteria Annexure-A
NoneNoneNoneNoneSelf certificate as per the prescribed format Annexure-BOthersQualify for award of this Contract the assessed available tender capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self certificate as per the prescribed format Annexure-B
NoneNoneNoneNoneUpload a Scanned copy of Attach self declaration certificate as per Tender notification Eligibility CriteriaOthersPerformance security for unbalance Rates
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of Attach self declaration certificate as per Tender notification Eligibility Criteria
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Upload a Scanned copy of attested Valid contractors Registration Certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of minimum built-up area as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of work done certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of work done certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of Liquid assets statement or availability of credit facilities letter of credit as per Tender notification Eligibility Criteria Annexure-AFalseTechnical Bid
Upload a Scanned copy of statement showing the maximum value of Civil Engineering works executed in any one year as per Tender notification Eligibility Criteria Self certificate as per the prescribed format Annexure-BFalseTechnical Bid
Performance security for unbalance RatesFalseTechnical Bid
Upload a Scanned copy of Attach self declaration certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724077179000
version0
createdDateNone
modifiedDateNone
blockNumberNear SP Circle
streetNone
cityBallari
stateKarnataka
pin583102
tenderRecallDTONone