createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724070683819
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1000.00
emd67800.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose29-08-2024 17:00:00
tenderQueryClose21-08-2024 15:00:00
technicalBidOpenNone
publishedDate19-08-2024 20:49:40
publishedByPostKKRTC_EE_HOFF_BLR
publishedByUserKPE10109 - M ERESH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate23-08-2024 12:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM.Eresh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08392294828
mobileNumber9972039797
tenderSupplierListNone
tenderSchedule
createdTs1724070683854
version6
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/OW/WORK_INDENT126
titleConstruction of Crew Rest Room and allied additional and alteration works to the First floor of Newly constructed ADM Block in Depot at Gangavati (Koppal District) (Call-2)
descriptionConstruction of Crew Rest Room and allied additional and alteration works to the First floor of Newly constructed ADM Block in Depot at Gangavati (Koppal District) (Call-2)
categoryWORKS
categoryTextWorks
ecv4000000.00
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5937
locationNameKKRTC Divisional Controller Office Bellari
provisionalAmount4000000.0
groupOverheadTotal614057.06
fileNumber10028
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17240706840000NoneNoneOther WorksConstruction of Crew Rest Room and allied additional and alteration works to the First floor of Newly constructed ADM Block in Depot at Gangavati (Koppal District) (Call-2)3385942.94
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3814094144832Nonecode01Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12336.8912336.897.97FalseNoneNoneFalseNoneFalse98325.01330
3814095144832Nonecode02Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6791.436791.432.02FalseNoneNoneFalseNoneFalse13718.68860
3814096144832Nonecode03Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11611.1911611.1910.95FalseNoneNoneFalseNoneFalse127142.53050
3814097144832Nonecode04Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internalframe with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed andfastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side Teak (105/12.57.4)Sqm4806.184806.1812.96FalseNoneNoneFalseNoneFalse62288.09280
3814098144832Nonecode05Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum131716.21131716.210.36FalseNoneNoneFalseNoneFalse47417.83560
3814099144832Nonecode06Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg178.15178.15680.4FalseNoneNoneFalseNoneFalse121213.260
3814100144832Nonecode07Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SRP- Voll (14/6.8)Cum8451.118451.1171.19FalseNoneNoneFalseNoneFalse601634.52090
3814101144832Nonecode08Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Voll (41/8.2.1)Sqm312.84312.84260.34FalseNoneNoneFalseNoneFalse81444.76560
3814102144832Nonecode09Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Voll (41/8.1.1)Sqm270.42270.42225.44FalseNoneNoneFalseNoneFalse60963.48480
3814103144832Nonecode10Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel crews, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. SRP- Voll (87/11.35.1.2)Kg518.57518.57193.23FalseNoneNoneFalseNoneFalse100203.28110
3814104144832Nonecode11Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, sage charges of machinery complete as per specifications. SRP- Voll (89/ 11.37.2)Sqm1241.841241.8433.84FalseNoneNoneFalseNoneFalse42023.86560
3814105144832Nonecode12Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm SRP- Vol-ll (62/ 9.22.2)Sqm1406.211406.21223.38FalseNoneNoneFalseNoneFalse314119.18980
3814106144832Nonecode13Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement complete as per drawing and technical specification. Building works SRP- Vol-l (18/ 2.11a)Kg94869.1494869.142.85FalseNoneNoneFalseNoneFalse270377.0490
3814107144832Nonecode14Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-Il (50/ 8.51)Sqm106.04106.04260.34FalseNoneNoneFalseNoneFalse27606.45360
3814108144832Nonecode15Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-II (45/ 8.25)Sqm145.28145.28260.34FalseNoneNoneFalseNoneFalse37822.19520
3814109144832Nonecode16Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-II (45/ 8.28)Sqm94.3794.37225.44FalseNoneNoneFalseNoneFalse21274.77280
3814110144832Nonecode17Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (SRP-Vol-II/123/13.34)Ltr9.539.531000.0FalseNoneNoneFalseNoneFalse9530.00
3814111144832Nonecode18Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes (SRP-Vol-II/123/13.33.5)Mtr505.85505.8540.0FalseNoneNoneFalseNoneFalse20234.00
3814112144832Nonecode19Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes (SRP-Vol-II/123/13.33.3)Mtr313.9313.930.0FalseNoneNoneFalseNoneFalse9417.00
3814113144832Nonecode20Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes (SRP-Vol-II/123/13.33.2)Mtr230.12230.1260.0FalseNoneNoneFalseNoneFalse13807.20
3814114144832Nonecode21Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 15 mm nominal dia Pipes (SRP-Vol-II/123/13.33.1)Mtr176.03176.0350.0FalseNoneNoneFalseNoneFalse8801.50
3814115144832Nonecode22White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (SRP-Vol-II/132/14.7.4)Each2486.862486.862.0FalseNoneNoneFalseNoneFalse4973.720
3814116144832Nonecode23Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm (SRP-Vol-II/134/14.13.2)Each2472.012472.016.0FalseNoneNoneFalseNoneFalse14832.060
3814117144832Nonecode24Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (SRP-Vol-II/131/14.2.1)Each5079.895079.892.0FalseNoneNoneFalseNoneFalse10159.780
3814118144832Nonecode25Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (SRP-Vol-II/136/14.31)Unit1281.01281.02.0FalseNoneNoneFalseNoneFalse2562.00
3814119144832Nonecode26Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (SRP-Vol-II/127/13.59)Nos231.0231.02.0FalseNoneNoneFalseNoneFalse462.00
3814120144832Nonecode27Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore (SRP-Vol-II/117/13.5.1)Nos310.79310.795.0FalseNoneNoneFalseNoneFalse1553.950
3814121144832Nonecode28Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore (SRP-Vol-II/117/13.4.3)Nos737.09737.092.0FalseNoneNoneFalseNoneFalse1474.180
3814122144832Nonecode29Providing and fixing brass stop cock of approved quality 15 mm nominal bore (SRP-Vol-II/117/13.3.1)Nos313.94313.948.0FalseNoneNoneFalseNoneFalse2511.520
3814123144832Nonecode30Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (SRP-Vol-II/60/9.11)Sqm933.44933.447.96FalseNoneNoneFalseNoneFalse7430.18240
3814124144832Nonecode31Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (SRP-Vol-II/63/9.24)Sqm2994.592994.597.56FalseNoneNoneFalseNoneFalse22639.10040
3814125144832Nonecode32Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar (SRP-Vol-II/187/19.7.3)Cum1080.441080.446.72FalseNoneNoneFalseNoneFalse7260.55680
3814126144832Nonecode33Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (SRP-Vol-II/187/19.3)Cum2499.162499.166.57FalseNoneNoneFalseNoneFalse16419.48120
3814127144832Nonecode34Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (SRP-Vol-II/65/9.39)Sqm1536.651536.6511.0FalseNoneNoneFalseNoneFalse16903.150
3814128144832Nonecode35Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surfaces (SRP-Vol-II/24/7.28.1)Sqm1351.071351.0778.88FalseNoneNoneFalseNoneFalse106572.40160
3814129144832Nonecode36Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SRP-Vol-II/83/11.16.3)Kg129.37129.374301.28FalseNoneNoneFalseNoneFalse556456.59360
3814130144832Nonecode37Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required (SRP-Vol-II/26/7.38)Sqm602.35602.35266.54FalseNoneNoneFalseNoneFalse160550.3690
3814131144832Nonecode38Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (SRP-Vol-II/65/9.38)Sqm1461.591461.5943.68FalseNoneNoneFalseNoneFalse63842.25120
3814132144832Nonecode39SRP: 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr82.9482.94140.0FalseNoneNoneFalseNoneFalse11611.60
3814133144832Nonecode401.1.2 Open Conduit System:Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr85.0485.0460.0FalseNoneNoneFalseNoneFalse5102.40
3814134144832Nonecode41SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm 2.3.2Mtr27.2927.29251.0FalseNoneNoneFalseNoneFalse6849.790
3814135144832Nonecode42SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm (P6/2.3.3)Mtr44.0944.09750.0FalseNoneNoneFalseNoneFalse33067.50
3814136144832Nonecode43SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4sqmm (P6/2.3.4)Mtr66.1466.14150.0FalseNoneNoneFalseNoneFalse9921.00
3814137144832Nonecode44SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6sqmm (P6/2.3.5)Mtr96.5996.5925.0FalseNoneNoneFalseNoneFalse2414.750
3814138144832Nonecode45SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo282.44282.446.0FalseNoneNoneFalseNoneFalse1694.640
3814139144832Nonecode46SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2)No397.94397.9415.0FalseNoneNoneFalseNoneFalse5969.10
3814140144832Nonecode47SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3)No582.74582.7430.0FalseNoneNoneFalseNoneFalse17482.20
3814141144832Nonecode48Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-3Way 3.4.1No144.89144.892.0FalseNoneNoneFalseNoneFalse289.780
3814142144832Nonecode49Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5way (P15/3.4.3)No185.84185.846.0FalseNoneNoneFalseNoneFalse1115.040
3814143144832Nonecode50Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 way (P15/3.4.4)No231.0231.05.0FalseNoneNoneFalseNoneFalse1155.00
3814144144832Nonecode51Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 way (P15/3.4.6)No334.94334.9414.0FalseNoneNoneFalseNoneFalse4689.160
3814145144832Nonecode52Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module 3.5.1No143.84143.842.0FalseNoneNoneFalseNoneFalse287.680
3814146144832Nonecode53Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 mod (P16/3.5.3)No183.74183.746.0FalseNoneNoneFalseNoneFalse1102.440
3814147144832Nonecode54Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module (P16/3.5.4)No245.69245.695.0FalseNoneNoneFalseNoneFalse1228.450
3814148144832Nonecode55Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 Module (P16/3.5.6)No361.19361.1914.0FalseNoneNoneFalseNoneFalse5056.660
3814149144832Nonecode56Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1No107.09107.0970.0FalseNoneNoneFalseNoneFalse7496.30
3814150144832Nonecode57Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3 way socket (P16/3.6.3)No179.54179.5420.0FalseNoneNoneFalseNoneFalse3590.80
3814151144832Nonecode58Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. modular stepped fan regulator (P16/3.6.4)No374.84374.8418.0FalseNoneNoneFalseNoneFalse6747.120
3814152144832Nonecode59Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch (P16/3.6.7)No189.0189.04.0FalseNoneNoneFalseNoneFalse756.00
3814153144832Nonecode60Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal socket (P16/3.6.10)No247.79247.794.0FalseNoneNoneFalseNoneFalse991.160
3814154144832Nonecode61Supplying and fixing Fan box with round hook (P3/1.13)No122.84122.8415.0FalseNoneNoneFalseNoneFalse1842.60
3814155144832Nonecode62Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2Mtr23.0923.0910.0FalseNoneNoneFalseNoneFalse230.90
3814156144832Nonecode63Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fighting 1 x4'- 20/22 wNo724.5724.525.0FalseNoneNoneFalseNoneFalse18112.50
3814157144832Nonecode64SRP 11.6.2 Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. Efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light LED modular down light 11.6.2LED modular down light 1'x1' 24WNo3876.593876.5910.0FalseNoneNoneFalseNoneFalse38765.90
3814158144832Nonecode6511.8.4 Supply of LED Streetlight luminaire 90 watt with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo9303.09303.02.0FalseNoneNoneFalseNoneFalse18606.00
3814159144832Nonecode666.3.1. Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.No3133.193133.1914.0FalseNoneNoneFalseNoneFalse43864.660
3814160144832Nonecode676.2.1 Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm) 7.2.1No3117.443117.442.0FalseNoneNoneFalseNoneFalse6234.880
3814161144832Nonecode68Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders 13.7.1No128.09128.0930.0FalseNoneNoneFalseNoneFalse3842.70
3814162144832Nonecode69Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe 13.2.3No1551.891551.896.0FalseNoneNoneFalseNoneFalse9311.340
3814163144832Nonecode706.5.1 Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.No2616.592616.595.0FalseNoneNoneFalseNoneFalse13082.950
3814164144832Nonecode71Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.13.10No179.54179.5419.0FalseNoneNoneFalseNoneFalse3411.260
3814165144832Nonecode72Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.13.13No742.34742.342.0FalseNoneNoneFalseNoneFalse1484.680
3814166144832Nonecode73Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SPNo435.74435.744.0FalseNoneNoneFalseNoneFalse1742.960
3814167144832Nonecode74Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP. (5.18.2)No775.94775.945.0FalseNoneNoneFalseNoneFalse3879.70
3814168144832Nonecode75Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps TPN. (5.18.7)No1802.841802.841.0FalseNoneNoneFalseNoneFalse1802.840
3814169144832Nonecode76SRP 5.19.10 Supplying and fixing regular MCB distribution board sonwall/ oodboard/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3phase/ single door with powder coate dpainting Madeoutof14SWGMS enclosure 16 Way SP &No3053.393053.391.0FalseNoneNoneFalseNoneFalse3053.390
3814170144832Nonecode77SRP3.14.6 Supplying And fixing/replacing of 6A Lamp Holder on existing switch board.No74.5474.5428.0FalseNoneNoneFalseNoneFalse2087.120
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17240706850000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17240706850000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17240706850000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17240706850000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17240706850000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17240706850000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17240706850000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17240706850000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17240706850000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17240706850000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17240706850000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17240706850000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17240706850000NoneNoneELIGIBILITYBanker Details for referenceNone
17240706850000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17240706850000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17240706850000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17240706850000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
17240706970000NoneNoneELIGIBILITYEstimated Rates inclusive of all taxes.None
17240707050000NoneNoneELIGIBILITYGST Shall be paid to the Tendered amount separately.None
17240707100000NoneNoneELIGIBILITYThe Government and the Contractor shall be bound to pay / refund of GST rates during the validity period of the contract to execute the work.None
17240707170000NoneNoneELIGIBILITYTerms and Conditions as per tender notificationNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Upload a Scanned copy of attested Valid contractors Registration Certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of work done certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of Quantities work done certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per Tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of Attach self declaration certificate as per Tender notification Eligibility CriteriaFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724078605000
version0
createdDateNone
modifiedDateNone
blockNumberNear SP Circle
streetNone
cityBallari
stateKarnataka
pin583102
tenderRecallDTONone