createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722955257723
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2550.00
emd154680.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-08-2024 17:00:00
tenderQueryClose28-08-2024 17:00:00
technicalBidOpen31-08-2024 17:00:01
publishedDate19-08-2024 12:47:12
publishedByPostRDPR_EE_DIV_VJN
publishedByUserKPE18071 - SABANNA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate17-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE OFFICE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9482100616
tenderSupplierListNone
tenderSchedule
createdTs1722955257768
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT7246
titleConstruction of School Buildings at 1. GHPS GIRLS(MODEL)-HARAPANAHALLI (29140710402)- 16.53 lakhs 2. GHPS-8th WARD H.HALLI (29140711401) 16.53 lakhs 3. GHPS ASHRAYA CAMP, HARIHARA ROAD (29140710501) 16.53 lakhs, 4. GOVT PU COLLEGE HS SECTION LAXMIPURA (29140704902) 18.50 lakhs, 5. GHS-KUNCHUR (29140704706) 18.50 lakhs 6. GHPS(BOYS)-KANCHIKERE (29140704302) 16.53 lakhs, 7. GHPS(URDU) UPGRADED H.S- BANAGERE(RMSA) (29140709306)- 16.53 lakhs
descriptionConstruction of School Buildings at 1. GHPS GIRLS(MODEL)-HARAPANAHALLI (29140710402)- 16.53 lakhs 2. GHPS-8th WARD H.HALLI (29140711401) 16.53 lakhs 3. GHPS ASHRAYA CAMP, HARIHARA ROAD (29140710501) 16.53 lakhs, 4. GOVT PU COLLEGE HS SECTION LAXMIPURA (29140704902) 18.50 lakhs, 5. GHS-KUNCHUR (29140704706) 18.50 lakhs 6. GHPS(BOYS)-KANCHIKERE (29140704302) 16.53 lakhs, 7. GHPS(URDU) UPGRADED H.S- BANAGERE(RMSA) (29140709306)- 16.53 lakhs
categoryWORKS
categoryTextWorks
ecv10199089.93
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location943
locationNameRDPR Division Office Vijayanagara
provisionalAmount10312000.0
groupOverheadTotal1555793.38
fileNumberHrp/KKRDB/2023-24/131
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17229552580000NoneNoneBuildingsConstruction of School Buildings at 1. GHPS GIRLS(MODEL)-HARAPANAHALLI (29140710402)- 16.53 lakhs 2. GHPS-8th WARD H.HALLI (29140711401) 16.53 lakhs 3. GHPS ASHRAYA CAMP, HARIHARA ROAD (29140710501) 16.53 lakhs, 4. GOVT PU COLLEGE HS SECTION LAXMIPURA (29140704902) 18.50 lakhs, 5. GHS-KUNCHUR (29140704706) 18.50 lakhs 6. GHPS(BOYS)-KANCHIKERE (29140704302) 16.53 lakhs, 7. GHPS(URDU) UPGRADED H.S- BANAGERE(RMSA) (29140709306)- 16.53 lakhs8643296.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3707595136751Nonecode01GHPS:Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.1187.64FalseNoneNoneFalseNoneFalse47679.3240
3707596136751Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4556.6FalseNoneNoneFalseNoneFalse355926.270
3707597136751Nonecode03Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4596.6FalseNoneNoneFalseNoneFalse648036.270
3707598136751Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (It.No.2.1.3 Page.no.15)Cum6527.856527.854.52FalseNoneNoneFalseNoneFalse29505.8820
3707599136751Nonecode05Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3161.8FalseNoneNoneFalseNoneFalse45190.740
3707600136751Nonecode06Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8367.458367.4565.92FalseNoneNoneFalseNoneFalse551582.3040
3707601136751Nonecode07Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3522.96FalseNoneNoneFalseNoneFalse151566.9960
3707602136751Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6961.56961.584.64FalseNoneNoneFalseNoneFalse589221.360
3707603136751Nonecode09Polyurethane based Single Component for New Surface : Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm857.85857.85221.72FalseNoneNoneFalseNoneFalse190202.5020
3707604136751Nonecode10Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne93929.8593929.859.76FalseNoneNoneFalseNoneFalse916755.3360
3707605136751Nonecode11Form work, centering and scaffolding for FoundationCum198.04198.0422.96FalseNoneNoneFalseNoneFalse4546.99840
3707606136751Nonecode12Form work, centering and scaffolding for Columns & PiersCum4873.054873.0520.48FalseNoneNoneFalseNoneFalse99800.0640
3707607136751Nonecode13Form work, centering and scaffolding for Chejja, Canopy and other Architectural projections of minor sections.Cum3132.683132.680.56FalseNoneNoneFalseNoneFalse1754.30080
3707608136751Nonecode14Form work, centering and scaffolding for Beams & Lintels of BuildingCum4176.94176.918.2FalseNoneNoneFalseNoneFalse76019.580
3707609136751Nonecode15Form work, centering and scaffolding for Roof (Straight & Arched) of BuildingCum3480.753480.7545.4FalseNoneNoneFalseNoneFalse158026.050
3707610136751Nonecode16Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75279.44FalseNoneNoneFalseNoneFalse86556.540
3707611136751Nonecode17Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm404.25404.25642.52FalseNoneNoneFalseNoneFalse259738.710
3707612136751Nonecode18Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0202.24FalseNoneNoneFalseNoneFalse21235.20
3707613136751Nonecode19Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4701.94701.98.84FalseNoneNoneFalseNoneFalse41564.7960
3707614136751Nonecode20Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg155.4155.4691.2FalseNoneNoneFalseNoneFalse107412.480
3707615136751Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.4544.32FalseNoneNoneFalseNoneFalse96018.0480
3707616136751Nonecode22Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1622.251622.25212.96FalseNoneNoneFalseNoneFalse345474.360
3707617136751Nonecode23Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1231.651231.6515.32FalseNoneNoneFalseNoneFalse18868.8780
3707618136751Nonecode24Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.Sqm473.55473.55104.36FalseNoneNoneFalseNoneFalse49419.6780
3707619136751Nonecode25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm143.85143.85499.04FalseNoneNoneFalseNoneFalse71786.9040
3707620136751Nonecode26Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm93.4593.45659.88FalseNoneNoneFalseNoneFalse61665.7860
3707621136751Nonecode27Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7570.08FalseNoneNoneFalseNoneFalse8462.160
3707622136751Nonecode28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg593.25593.25257.04FalseNoneNoneFalseNoneFalse152488.980
3707623136751Nonecode29Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.Mtr302.4302.448.0FalseNoneNoneFalseNoneFalse14515.20
3707624136751Nonecode30Cement BoardSqm308.7308.711.52FalseNoneNoneFalseNoneFalse3556.2240
3707625136751Nonecode31Chicken MeshSqm12.612.6248.32FalseNoneNoneFalseNoneFalse3128.8320
3707626136751Nonecode324 Seater Reversible DeskNos7206.07206.024.0FalseNoneNoneFalseNoneFalse172944.00
3707627136751Nonecode33Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804Nos9450.09450.04.0FalseNoneNoneFalseNoneFalse37800.00
3707628136751Nonecode34Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessaryMtr78.078.0160.0FalseNoneNoneFalseNoneFalse12480.00
3707629136751Nonecode35Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr79.079.0200.0FalseNoneNoneFalseNoneFalse15800.00
3707630136751Nonecode36Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc..- 180x90x65mmNos161.0161.04.0FalseNoneNoneFalseNoneFalse644.00
3707631136751Nonecode37Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.(300x300x76mm)Mtr120.0120.04.0FalseNoneNoneFalseNoneFalse480.00
3707632136751Nonecode38Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manmanufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WNos690.0690.016.0FalseNoneNoneFalseNoneFalse11040.00
3707633136751Nonecode39Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system - 48" Sweep (1200mm) Regular modelNos2984.02984.08.0FalseNoneNoneFalseNoneFalse23872.00
3707634136751Nonecode40Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switchPoint285.0285.08.0FalseNoneNoneFalseNoneFalse2280.00
3707635136751Nonecode41Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchPoint394.0394.08.0FalseNoneNoneFalseNoneFalse3152.00
3707636136751Nonecode42Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switchPoint570.0570.08.0FalseNoneNoneFalseNoneFalse4560.00
3707637136751Nonecode43Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 3/5 WayNos147.0147.024.0FalseNoneNoneFalseNoneFalse3528.00
3707638136751Nonecode44Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.Sqm0.350.351200.0FalseNoneNoneFalseNoneFalse420.00
3707639136751Nonecode45Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Nos739.0739.04.0FalseNoneNoneFalseNoneFalse2956.00
3707640136751Nonecode46GHS:Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.1101.24FalseNoneNoneFalseNoneFalse25725.0840
3707641136751Nonecode47Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4527.62FalseNoneNoneFalseNoneFalse173686.9890
3707642136751Nonecode48Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4531.24FalseNoneNoneFalseNoneFalse209571.9780
3707643136751Nonecode49Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (It.No.2.1.3 Page.no.15)Cum6527.856527.852.56FalseNoneNoneFalseNoneFalse16711.2960
3707644136751Nonecode50Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.383.14FalseNoneNoneFalseNoneFalse23221.0020
3707645136751Nonecode51Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8367.458367.4540.78FalseNoneNoneFalseNoneFalse341224.6110
3707646136751Nonecode52Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3515.3FalseNoneNoneFalseNoneFalse101000.6550
3707647136751Nonecode53Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6961.56961.551.66FalseNoneNoneFalseNoneFalse359631.090
3707648136751Nonecode54Polyurethane based Single Component for New Surface : Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm857.85857.85143.08FalseNoneNoneFalseNoneFalse122741.1780
3707649136751Nonecode55Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne93929.8593929.855.984FalseNoneNoneFalseNoneFalse562076.22240
3707650136751Nonecode56Form work, centering and scaffolding for FoundationCum198.04198.0415.3FalseNoneNoneFalseNoneFalse3030.0120
3707651136751Nonecode57Form work, centering and scaffolding for Columns & PiersCum4873.054873.0511.08FalseNoneNoneFalseNoneFalse53993.3940
3707652136751Nonecode58Form work, centering and scaffolding for Chejja, Canopy and other Architectural projections of minor sections.Cum3132.683132.680.4FalseNoneNoneFalseNoneFalse1253.0720
3707653136751Nonecode59Form work, centering and scaffolding for Beams & Lintels of BuildingCum4176.94176.911.68FalseNoneNoneFalseNoneFalse48786.1920
3707654136751Nonecode60Form work, centering and scaffolding for Roof (Straight & Arched) of BuildingCum3480.753480.7528.48FalseNoneNoneFalseNoneFalse99131.760
3707655136751Nonecode61Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75166.84FalseNoneNoneFalseNoneFalse51678.690
3707656136751Nonecode62Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm404.25404.25384.26FalseNoneNoneFalseNoneFalse155337.1050
3707657136751Nonecode63Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0127.92FalseNoneNoneFalseNoneFalse13431.60
3707658136751Nonecode64Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4701.94701.94.42FalseNoneNoneFalseNoneFalse20782.3980
3707659136751Nonecode65Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg155.4155.4432.0FalseNoneNoneFalseNoneFalse67132.80
3707660136751Nonecode66Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.4340.2FalseNoneNoneFalseNoneFalse60011.280
3707661136751Nonecode67Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1622.251622.25133.56FalseNoneNoneFalseNoneFalse216667.710
3707662136751Nonecode68Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1231.651231.659.26FalseNoneNoneFalseNoneFalse11405.0790
3707663136751Nonecode69Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm143.85143.85305.06FalseNoneNoneFalseNoneFalse43882.8810
3707664136751Nonecode70Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm93.4593.45394.56FalseNoneNoneFalseNoneFalse36871.6320
3707665136751Nonecode71Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7541.38FalseNoneNoneFalseNoneFalse4996.6350
3707666136751Nonecode72Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg593.25593.25128.52FalseNoneNoneFalseNoneFalse76244.490
3707667136751Nonecode73Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.Mtr302.4302.424.0FalseNoneNoneFalseNoneFalse7257.60
3707668136751Nonecode74Cement BoardSqm308.7308.75.76FalseNoneNoneFalseNoneFalse1778.1120
3707669136751Nonecode75Chicken MeshSqm12.612.6154.3FalseNoneNoneFalseNoneFalse1944.180
3707670136751Nonecode764 Seater Reversible DeskNos7206.07206.016.0FalseNoneNoneFalseNoneFalse115296.00
3707671136751Nonecode77Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804Nos9450.09450.02.0FalseNoneNoneFalseNoneFalse18900.00
3707672136751Nonecode78Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessaryMtr78.078.0100.0FalseNoneNoneFalseNoneFalse7800.00
3707673136751Nonecode79Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr79.079.0120.0FalseNoneNoneFalseNoneFalse9480.00
3707674136751Nonecode80Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc..- 180x90x65mmNos161.0161.02.0FalseNoneNoneFalseNoneFalse322.00
3707675136751Nonecode81Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.(300x300x76mm)Mtr120.0120.02.0FalseNoneNoneFalseNoneFalse240.00
3707676136751Nonecode82Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manmanufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WNos690.0690.012.0FalseNoneNoneFalseNoneFalse8280.00
3707677136751Nonecode83Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system - 48" Sweep (1200mm) Regular modelNos2984.02984.06.0FalseNoneNoneFalseNoneFalse17904.00
3707678136751Nonecode84Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switchPoint285.0285.06.0FalseNoneNoneFalseNoneFalse1710.00
3707679136751Nonecode85Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchPoint394.0394.06.0FalseNoneNoneFalseNoneFalse2364.00
3707680136751Nonecode86Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switchPoint570.0570.06.0FalseNoneNoneFalseNoneFalse3420.00
3707681136751Nonecode87Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 3/5 WayNos147.0147.012.0FalseNoneNoneFalseNoneFalse1764.00
3707682136751Nonecode88Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.Sqm0.350.35600.0FalseNoneNoneFalseNoneFalse210.00
3707683136751Nonecode89Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Nos739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
3707684136751Nonecode90Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge - For thickness of tiles 10 mm to 25 mmSqm50.450.461.11FalseNoneNoneFalseNoneFalse3079.9440
3707685136751Nonecode91Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Cum1746.151746.154.88FalseNoneNoneFalseNoneFalse8521.2120
3707686136751Nonecode92Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2547.32547.37.3FalseNoneNoneFalseNoneFalse18595.290
3707687136751Nonecode93Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum1080.451080.4512.09FalseNoneNoneFalseNoneFalse13062.64050
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17229552590000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17229552590000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17229552590000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17229552590000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17229552590000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17229556220000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 - Qualification of the Tenderer in Section 2 : Instructions to Tenderers (ITT), will only be considered for evaluation.None
17229556340000NoneNoneELIGIBILITYThe tenderer should quote his rates With all leads and lifts loading and un loading, including cost of Labour, hire charges of Machinery and other incidental charges etc complete as per the directions of the engineer incharge of the work specifications.None
17229556440000NoneNoneELIGIBILITYDefect liability period of 1 year and 1 year for major repairs to be considered.(Maintenance date starts from the date of completion period.) All the items included in the estimate are inclusive of lead and lift charges.None
17229556590000NoneNoneELIGIBILITYThe work will be inspected by the third party & the bill will be admitted only after the satisfactory quality report from third party.None
17229556670000NoneNoneELIGIBILITYIt is to be noted that any false documentation is found to be uploaded, the action may attract punitive measures such as blacklisting, cancellation of registration etc.None
17229556740000NoneNoneELIGIBILITYContractor should made an agreement within 20 days from the date of LOA. work should be commence within 2 weeks time from the date of work order. If not tender will be cancelled at the contractors own risk and cost.None
17229556800000NoneNoneELIGIBILITYAll materials shall be of good quality as per specification, quality certificate for the same should be obtained from the concerned authority at their own cost.None
17229556860000NoneNoneELIGIBILITYThe Information on litigation in which the tender is involved are to be furnishedNone
17229556940000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year (both days inclusive)None
17229557140000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason.None
17229557220000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 Qualification of the Tenderer in Section 2 Instructions to Tenderers will only be considered for evaluationNone
17229557300000NoneNoneELIGIBILITYThe rates of all the items appeared in Bill of Quantities are inclusive of all leads and liftsNone
17229557360000NoneNoneELIGIBILITYBidders are advised to note that, 18% GST will be added to the contract amount.None
17229557450000NoneNoneELIGIBILITYThe Increase in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of timeNone
17229557550000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate failing which bid is rejectedNone
17229557660000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clauseNone
17229557790000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10per per year to bring them to the price level of the 2023 24 in the Technical Qualification Criteria mentioned in the next sectionNone
17229557860000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year (both days inclusive).None
17229557940000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17229558020000NoneNoneELIGIBILITYDefect liability period will be one yearNone
17229558160000NoneNoneELIGIBILITYSubmit the Bid capacity calculation sheetNone
17229558250000NoneNoneELIGIBILITYWork completion period as mentioned in bid documentNone
17229558350000NoneNoneELIGIBILITYAll other conditions and requirements has to be fulfilled as per the attached standard bid document Technical Qualification Criteria of KW-4 and General instructionsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneWork done certificate Bidder should have satisfactorily completed at least one similar nature of work of value not less than the amount of Rs 50.99Lakhs in any one year during the previous five years ie 2019-20 to 2023-24 The cost of works executed in previous years shall be updated to 2023-24 at 10 percent per annum (BUILDING). Work done certificate must have Indent number, otherwise bid will not be taken into consideration.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe tenderers who meet the above specified minimum qualifying criteria will be qualified if there available tender capacity is more than the total tender value the available tender capacity will be calculated as under assist available tender capacity AxNx1.5-BCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneExecuted in any one year for a continuous period of 12 months the minimum quantities of work. 2019-20 to 2023-24 80% of the estimated quantity required 1 Earthwork 575.00 cum 2 RCC/PCC 290.40 cum 3 SSM/BBM 245.24 cum 4 Steel 17.37 Tonne 5 Plastering 1653.00 sqm 6 Flooring 18.64 Sqm IMP.Note- Separate year wise 80 percent quantity with works list sheet strictly to be enclosed. other wise bid may not be considerCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Itemwise Workdone certficate
NoneNoneNoneNoneAchieved in at least Two financial years a minimum financial turnover (in all classes of civil works only) of Rs.203.98Lakhs (Last 5 years 2019-20 to 2023-24) (usually not less than two times the estimated annual payments under this contract)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets or availability of credit facilities of no less than Rs.27.81Lakhs Credit lines or letter of credit or certificates from banks for meeting the fund requirement etc.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneConstitution/ legal status of Tenderer, Place of Registration , Principal place of business.OthersLegal Document
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration Certificate issued by KPWD
NoneNoneNoneNoneThe proposed methodology and program of construction, backed with equipment planning and deployment, duly supported with broad calculations and quality control procedures proposed to be adopted, justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion.OthersPERT
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- pert
NoneNoneNoneNoneInformation on works which are yet to be completed.OthersOngoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing works
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration copyTrueTechnical Bid
Last 5 years Audit Report with UDIN NoTrueTechnical Bid
Similar Nature Work done certificate with eproc Indent NoTrueTechnical Bid
Itemwise workdone certificateTrueTechnical Bid
Bid capacity Calculation sheetTrueTechnical Bid
Unconditional Line of credit from Nationalized BankTrueTechnical Bid
All other documents as per KW 4 Bid DocumentTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1723113068000
version0
createdDateNone
modifiedDateNone
blockNumberPRED
streetNone
cityHosapete
stateKarnataka
pin583219
tenderRecallDTONone