3786436 | 143048 | None | NMH01 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. FOR FIRST FLOOR | Cum | 1847.59 | 1847.59 | 132.78 | False | None | None | False | None | False | 245323.0002 | 0 |
3786437 | 143048 | None | NMH02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 112.2 | 112.2 | 146.18 | False | None | None | False | None | False | 16401.396 | 0 |
3786438 | 143048 | None | NMH03 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 176.0 | 176.0 | 161.21 | False | None | None | False | None | False | 28372.96 | 0 |
3786439 | 143048 | None | NMH04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. / Lindane 20percentage E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications | Sqm | 129.8 | 129.8 | 74.14 | False | None | None | False | None | False | 9623.372 | 0 |
3786440 | 143048 | None | NMH05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6230.4 | 6230.4 | 9.36 | False | None | None | False | None | False | 58316.544 | 0 |
3786441 | 143048 | None | NMH06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 40 mm nominal size graded crushed coarse aggregates FOR FIRST FLOOR | Cum | 6839.31 | 6839.31 | 1.06 | False | None | None | False | None | False | 7249.6686 | 0 |
3786442 | 143048 | None | NMH07 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) at 75percentage & GGBS at 25percentage proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge.RMC M25 GradeincludingPercentage Additionalities for Formwork, Centering & Scaffolding for Footings concrete | Cum | 7046.12 | 7046.12 | 6.14 | False | None | None | False | None | False | 43263.1768 | 0 |
3786443 | 143048 | None | NMH08 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) at 75percentage & GGBS at 25percentage proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge.RMC M25 GradeincludingPercentage Additionalities for Formwork, Centering & Scaffolding for COLUMNS GROUND FLOOR | Cum | 11629.53 | 11629.53 | 3.97 | False | None | None | False | None | False | 46169.2341 | 0 |
3786444 | 143048 | None | NMH09 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) at 75percentage & GGBS at 25percentage proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge.RMC M25 GradeincludingPercentage Additionalities for Formwork, Centering & Scaffolding FORCOLUMNS FIRSTFLOOR | Cum | 11697.94 | 11697.94 | 1.53 | False | None | None | False | None | False | 17897.8482 | 0 |
3786445 | 143048 | None | NMH10 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) at 75percentage & GGBS at 25percentage proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge.RMC M25 GradeincludingPercentage Additionalities for Formwork, Centering & Scaffolding forROOF SLAB | Cum | 10329.75 | 10329.75 | 12.56 | False | None | None | False | None | False | 129741.66 | 0 |
3786446 | 143048 | None | NMH11 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) at 75percentage & GGBS at 25percentage proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge.RMC M25 GradeincludingPercentage Additionalities for Formwork, Centering & Scaffolding for LINTELS | Cum | 11013.84 | 11013.84 | 1.11 | False | None | None | False | None | False | 12225.3624 | 0 |
3786447 | 143048 | None | NMH12 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings FOR FIRST FLOOR | Tonne | 99386.72 | 99386.72 | 3.36 | False | None | None | False | None | False | 333939.3792 | 0 |
3786448 | 143048 | None | NMH13 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge FOR FIRST FLOOR | Kg | 125.54 | 125.54 | 11196.23 | False | None | None | False | None | False | 1405574.7142 | 0 |
3786449 | 143048 | None | NMH14 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge FOR FIRST FLOOR | Kg | 163.32 | 163.32 | 21757.43 | False | None | None | False | None | False | 3553423.4676 | 0 |
3786450 | 143048 | None | NMH15 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FOR FIRST FLOOR | Sqm | 127.76 | 127.76 | 1020.92 | False | None | None | False | None | False | 130432.7392 | 0 |
3786451 | 143048 | None | NMH16 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 91.3 | 91.3 | 198.45 | False | None | None | False | None | False | 18118.485 | 0 |
3786452 | 143048 | None | NMH17 | Providing and fixing roofing consist of 0.8 mm thick Galvanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). FOR FIRST FLOOR | Sqm | 1292.09 | 1292.09 | 83.74 | False | None | None | False | None | False | 108199.6166 | 0 |
3786453 | 143048 | None | NMH18 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) FOR FIRST FLOOR | Sqm | 7481.47 | 7481.47 | 25.2 | False | None | None | False | None | False | 188533.044 | 0 |
3786454 | 143048 | None | NMH19 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&Psshall not be made) FOR FIRST FLOOR | Sqm | 6938.19 | 6938.19 | 12.6 | False | None | None | False | None | False | 87421.194 | 0 |
3786455 | 143048 | None | NMH20 | Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work 50mm thickness FOR FIRST FLOOR | Sqm | 2883.04 | 2883.04 | 1012.44 | False | None | None | False | None | False | 2918905.0176 | 0 |
3786456 | 143048 | None | NMH21 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws at 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board FOR FIRST FLOOR | Sqm | 1273.2 | 1273.2 | 77.67 | False | None | None | False | None | False | 98889.444 | 0 |
3786457 | 143048 | None | NMH22 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.FOR FIRST FLOOR | Sqm | 501.06 | 501.06 | 330.58 | False | None | None | False | None | False | 165640.4148 | 0 |
3786458 | 143048 | None | NMH23 | Providing, installing WOODEN FLOORING Surface board Maple WOOD SPORTS FLOORING of approved make finishing with 21mm thick, 53 to 92 mm wide and in random length in tongue and groove shape. The edges of the boards should have finger lock groove and the bottom side with air pass groove. The under frame- made of pine wood runners of 70 mm x 45 mm, treated with anti-termite solution and fixed on the bottom side with 19/10mm thick EPDM air cushioned pads, stapled through the two wings at 350 mm x 350 mm. Installation - IPS subfloor treated with a vapor barrier to be placed on the leveled IPS sub floor before laying the under frame. The runners having air cushion pads to be placed on the vapor barrier in perfect level at 350 mm in 1 direction. The surface board to be screwed to the runner through the tongue only and will lock the screwed tongue by the groove of adjoining board. Ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion of 12 to 15 mm to be left open between the wooden flooring the surrounding tiled area / walls. Finishing - After installation the floor will be machine sanded in uniform level and finishing with P.U. POLISHING water based polyurethane lacquer Game line marking to be carried out in required colors beforeapplying the finishing coat. The unit cost is including all lead, lift, loading, unloading, transportation, labour, field testing and all other incidental charges complete as per the directions of Engineer in charge of the work. | Sqm | 7000.0 | 7000.0 | 318.84 | False | None | None | False | None | False | 2231880.0 | 0 |
3786459 | 143048 | None | NMH24 | ANCHORING HILTI BOLTS Providing and fixing the chemical anchor fasteners of hilti make HIT RE 500 make conforming to IS 1367 part 3 at required locations and levels including drilling the hole, cleaning with blow pump and anchoring the bolt with chemical as mentioned below and as directed by the engineer in charge. The unit cost is including all lead, lift, loading, unloading, transportation, labour, solvent and all other incidental charges complete as per the directions of Engineer in charge of the work. | Each | 2500.0 | 2500.0 | 42.0 | False | None | None | False | None | False | 105000.0 | 0 |
3786460 | 143048 | None | NMH25 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 percentage) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth) FOR FIRST FLOOR | m | 1193.21 | 1193.21 | 38.0 | False | None | None | False | None | False | 45341.98 | 0 |
3786461 | 143048 | None | NMH26 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6Kg/m2: 110 mm(weight of pipe -1.894 kg) FOR FIRST FLOOR | m | 397.73 | 397.73 | 96.01 | False | None | None | False | None | False | 38186.0573 | 0 |
3786462 | 143048 | None | NMH27 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsFOR FIRST FLOOR | Cum | 1455.41 | 1455.41 | 64.52 | False | None | None | False | None | False | 93903.0532 | 0 |
3786463 | 143048 | None | NMH28 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FOR FIRST FLOOR | Sqm | 476.61 | 476.61 | 146.0 | False | None | None | False | None | False | 69585.06 | 0 |
3786464 | 143048 | None | NMH29 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67L/10 m² over and including priming coat of exterior primer applied at 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FOR FIRST FLOOR | Sqm | 193.31 | 193.31 | 220.14 | False | None | None | False | None | False | 42555.2634 | 0 |
3786465 | 143048 | None | NMH30 | Providing and fixing BADMINTON NET POLE and NET BWF APPROVED 2 poles (pole cover included) SPECS : Weight 100 kg / 220 lbs per pole and BADMINTON NET (Yonex logo printed on net) Weight 540 g Item Code AC141. The unit cost is including all lead, lift, loading, unloading, transportation, labour and all other incidental charges complete as per the directions of Engineer in charge of the work | Each | 225000.0 | 225000.0 | 2.0 | False | None | None | False | None | False | 450000.0 | 0 |
3786466 | 143048 | None | NMH31 | Providing and Badminton Court - Marking PiantWear-resistant Non-Slip Acrylic Court Paint, 100percentage acrylic-textured coating for use over asphalt, concrete or other surfaces, where an extremely durable,Anti Skid Coating for slip resistance. The unit cost is including all lead, lift, loading, unloading, transportation, labour and all other incidental charges complete as per the directions of Engineer in charge of the work | Ltr | 8000.0 | 8000.0 | 6.0 | False | None | None | False | None | False | 48000.0 | 0 |
3786467 | 143048 | None | NMH32 | Supply and Installation of Multicell Standing Seam polycarbonate panels having flux 7.0 as per EN 16153 & EN ISO 10077-2. For min joints, panel shall be 1000 - 1200 mm wide with standing seam on both sides. Panels shall have minimum six-seven layers with truss bridge design for higher flexibility and strength. The system shall be secured using suitable connectors with double tooth grip lock locking mechanism and fixed on purlin(to be paid separately) having a pull out load of min 7000N tested as per ISO 6892-1998 and IS 1608-2005. Panels must satisfy impact test as per IS 14443-97 shall show no sign of breakage which have been exposed to UV for 500 Hours (min) as per ASTM G 155. Panels shall have Yellowness Index of not more than 15 units as per ASTM D 1925 when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be closed at the end with additional Aluminium U profile as required. All aluminium should be factory finished / mill finished. Panel shall be fixed over MS structural steel / MS purlin (to be paid separately) conforming to the details in the specifications as per direction of Engineer in charge of work 18mm Thick Multicell Polycarbonate Panels having U value of 1.9 W/m2 K (max) FOR FIRST FLOOR | Sqm | 4321.79 | 4321.79 | 19.97 | False | None | None | False | None | False | 86306.1463 | 0 |
3786468 | 143048 | None | NMH33 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick | m | 75.9 | 75.9 | 750.0 | False | None | None | False | None | False | 56925.0 | 0 |
3786469 | 143048 | None | NMH34 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | m | 89.1 | 89.1 | 1000.0 | False | None | None | False | None | False | 89100.0 | 0 |
3786470 | 143048 | None | NMH35 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thick | m | 116.6 | 116.6 | 100.0 | False | None | None | False | None | False | 11660.0 | 0 |
3786471 | 143048 | None | NMH36 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5 mm thick | m | 163.9 | 163.9 | 50.0 | False | None | None | False | None | False | 8195.0 | 0 |
3786472 | 143048 | None | NMH37 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 19/20 mm deep Junction box | Each | 53.9 | 53.9 | 40.0 | False | None | None | False | None | False | 2156.0 | 0 |
3786473 | 143048 | None | NMH38 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 25 mm deep Junction box | Each | 61.6 | 61.6 | 40.0 | False | None | None | False | None | False | 2464.0 | 0 |
3786474 | 143048 | None | NMH39 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 32 mm deep Junction box | Each | 67.1 | 67.1 | 20.0 | False | None | None | False | None | False | 1342.0 | 0 |
3786475 | 143048 | None | NMH40 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.20 mm | m | 30.8 | 30.8 | 100.0 | False | None | None | False | None | False | 3080.0 | 0 |
3786476 | 143048 | None | NMH41 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.25 mm | m | 38.5 | 38.5 | 250.0 | False | None | None | False | None | False | 9625.0 | 0 |
3786477 | 143048 | None | NMH42 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.50 mm | m | 47.3 | 47.3 | 50.0 | False | None | None | False | None | False | 2365.0 | 0 |
3786478 | 143048 | None | NMH43 | Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mm | m | 20.9 | 20.9 | 100.0 | False | None | None | False | None | False | 2090.0 | 0 |
3786479 | 143048 | None | NMH44 | Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm | m | 24.2 | 24.2 | 50.0 | False | None | None | False | None | False | 1210.0 | 0 |
3786480 | 143048 | None | NMH45 | Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 50 mm | m | 51.7 | 51.7 | 50.0 | False | None | None | False | None | False | 2585.0 | 0 |
3786481 | 143048 | None | NMH46 | Supplying Galvanized steel flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mm | m | 58.3 | 58.3 | 50.0 | False | None | None | False | None | False | 2915.0 | 0 |
3786482 | 143048 | None | NMH47 | Supplying Galvanized steel flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm | m | 79.2 | 79.2 | 50.0 | False | None | None | False | None | False | 3960.0 | 0 |
3786483 | 143048 | None | NMH48 | Digging of trench of 0.6 m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)In soil (hard) | Mtr | 102.0 | 102.0 | 250.0 | False | None | None | False | None | False | 25500.0 | 0 |
3786484 | 143048 | None | NMH49 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) forC Ccutting | Mtr | 205.0 | 205.0 | 60.0 | False | None | None | False | None | False | 12300.0 | 0 |
3786485 | 143048 | None | NMH50 | Labour charges for laying of 1.1 KV class UG cablein existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. For 6 sqmm to 16 sqmm | Mtr | 11.88 | 11.88 | 250.0 | False | None | None | False | None | False | 2970.0 | 0 |
3786486 | 143048 | None | NMH51 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct.25 sqmm to 75 sqmm | Mtr | 15.5 | 15.5 | 150.0 | False | None | None | False | None | False | 2325.0 | 0 |
3786487 | 143048 | None | NMH52 | Supplying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397510 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)( material code 287205) | Rmtr | 129.8 | 129.8 | 100.0 | False | None | None | False | None | False | 12980.0 | 0 |
3786488 | 143048 | None | NMH53 | Supplying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397516 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)( material code 287206) | Rmtr | 156.02 | 156.02 | 250.0 | False | None | None | False | None | False | 39005.0 | 0 |
3786489 | 143048 | None | NMH54 | Supplying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397550 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)( material code 287208) | Rmtr | 196.86 | 196.86 | 150.0 | False | None | None | False | None | False | 29529.0 | 0 |
3786490 | 143048 | None | NMH55 | Supplying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975120 Sqmm, 3.5 Core, (23 GI Strips - 4 x 0.8 mm)( material code 287212) | Rmtr | 502.57 | 502.57 | 443.0 | False | None | None | False | None | False | 222638.51 | 0 |
3786491 | 143048 | None | NMH56 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20102.5sqmm | m | 46.2 | 46.2 | 1200.0 | False | None | None | False | None | False | 55440.0 | 0 |
3786492 | 143048 | None | NMH57 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20104 sqmm | m | 69.3 | 69.3 | 850.0 | False | None | None | False | None | False | 58905.0 | 0 |
3786493 | 143048 | None | NMH58 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20106 sqmm | m | 101.2 | 101.2 | 250.0 | False | None | None | False | None | False | 25300.0 | 0 |
3786494 | 143048 | None | NMH59 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:201010 sqmm | m | 183.7 | 183.7 | 100.0 | False | None | None | False | None | False | 18370.0 | 0 |
3786495 | 143048 | None | NMH60 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:201016 sqmm | m | 349.8 | 349.8 | 250.0 | False | None | None | False | None | False | 87450.0 | 0 |
3786496 | 143048 | None | NMH61 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3CX2.5 sqmm | m | 124.3 | 124.3 | 500.0 | False | None | None | False | None | False | 62150.0 | 0 |
3786497 | 143048 | None | NMH62 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3CX 4 sqmm | m | 189.2 | 189.2 | 50.0 | False | None | None | False | None | False | 9460.0 | 0 |
3786498 | 143048 | None | NMH63 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 1-2 Way | Each | 113.3 | 113.3 | 30.0 | False | None | None | False | None | False | 3399.0 | 0 |
3786499 | 143048 | None | NMH64 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 3 Way | Each | 136.4 | 136.4 | 10.0 | False | None | None | False | None | False | 1364.0 | 0 |
3786500 | 143048 | None | NMH65 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 4-5 Way | Each | 150.7 | 150.7 | 10.0 | False | None | None | False | None | False | 1507.0 | 0 |
3786501 | 143048 | None | NMH66 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 6 Way | Each | 190.3 | 190.3 | 24.0 | False | None | None | False | None | False | 4567.2 | 0 |
3786502 | 143048 | None | NMH67 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 8 Way | Each | 240.9 | 240.9 | 24.0 | False | None | None | False | None | False | 5781.6 | 0 |
3786503 | 143048 | None | NMH68 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 10-12 Way | Each | 287.1 | 287.1 | 36.0 | False | None | None | False | None | False | 10335.6 | 0 |
3786504 | 143048 | None | NMH69 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 18 Way | Each | 372.9 | 372.9 | 12.0 | False | None | None | False | None | False | 4474.8 | 0 |
3786505 | 143048 | None | NMH70 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 150.7 | 150.7 | 30.0 | False | None | None | False | None | False | 4521.0 | 0 |
3786506 | 143048 | None | NMH71 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 177.1 | 177.1 | 10.0 | False | None | None | False | None | False | 1771.0 | 0 |
3786507 | 143048 | None | NMH72 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 192.5 | 192.5 | 10.0 | False | None | None | False | None | False | 1925.0 | 0 |
3786508 | 143048 | None | NMH73 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 257.4 | 257.4 | 24.0 | False | None | None | False | None | False | 6177.6 | 0 |
3786509 | 143048 | None | NMH74 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 312.4 | 312.4 | 24.0 | False | None | None | False | None | False | 7497.6 | 0 |
3786510 | 143048 | None | NMH75 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 378.4 | 378.4 | 36.0 | False | None | None | False | None | False | 13622.4 | 0 |
3786511 | 143048 | None | NMH76 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 18 Module | Each | 502.7 | 502.7 | 12.0 | False | None | None | False | None | False | 6032.4 | 0 |
3786512 | 143048 | None | NMH77 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch | Each | 112.2 | 112.2 | 120.0 | False | None | None | False | None | False | 13464.0 | 0 |
3786513 | 143048 | None | NMH78 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket | Each | 188.1 | 188.1 | 60.0 | False | None | None | False | None | False | 11286.0 | 0 |
3786514 | 143048 | None | NMH79 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293Stepped Fan Regulator Two Module | Each | 392.7 | 392.7 | 28.0 | False | None | None | False | None | False | 10995.6 | 0 |
3786515 | 143048 | None | NMH80 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 600W Dimmer | Each | 361.9 | 361.9 | 2.0 | False | None | None | False | None | False | 723.8 | 0 |
3786516 | 143048 | None | NMH81 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch | Each | 198.0 | 198.0 | 24.0 | False | None | None | False | None | False | 4752.0 | 0 |
3786517 | 143048 | None | NMH82 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Bell Push | Each | 194.7 | 194.7 | 2.0 | False | None | None | False | None | False | 389.4 | 0 |
3786518 | 143048 | None | NMH83 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch | Each | 358.6 | 358.6 | 24.0 | False | None | None | False | None | False | 8606.4 | 0 |
3786519 | 143048 | None | NMH84 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal Socket | Each | 259.6 | 259.6 | 24.0 | False | None | None | False | None | False | 6230.4 | 0 |
3786520 | 143048 | None | NMH85 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote Ding Dong Bell | Each | 270.6 | 270.6 | 2.0 | False | None | None | False | None | False | 541.2 | 0 |
3786521 | 143048 | None | NMH86 | Supplying and fixing of metal clad industrial plugs and sockets.2pole+earth 250V PLUG 32A | Each | 602.8 | 602.8 | 4.0 | False | None | None | False | None | False | 2411.2 | 0 |
3786522 | 143048 | None | NMH87 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose | Each | 85.8 | 85.8 | 40.0 | False | None | None | False | None | False | 3432.0 | 0 |
3786523 | 143048 | None | NMH88 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Batten Holder | Each | 81.4 | 81.4 | 40.0 | False | None | None | False | None | False | 3256.0 | 0 |
3786524 | 143048 | None | NMH89 | Fabricating, supplying and erection of . ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom . mm , top. mm with 3 mm thick, suitable base plate and 4Nos of . long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. 5 m - Top 70 mm and Bottom 130 mm dia | Each | 10890.0 | 10890.0 | 4.0 | False | None | None | False | None | False | 43560.0 | 0 |
3786525 | 143048 | None | NMH90 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single Arm Bracket with 2000 mm Standard 40/50 mm dia | Each | 2860.0 | 2860.0 | 2.0 | False | None | None | False | None | False | 5720.0 | 0 |
3786526 | 143048 | None | NMH91 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., completeDouble Arm Bracket with 2000 mm Standard 40/50 mm dia | Each | 4180.0 | 4180.0 | 2.0 | False | None | None | False | None | False | 8360.0 | 0 |
3786527 | 143048 | None | NMH92 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with .W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70W | Each | 6591.2 | 6591.2 | 2.0 | False | None | None | False | None | False | 13182.4 | 0 |
3786528 | 143048 | None | NMH93 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 120 W | Each | 11066.0 | 11066.0 | 1.0 | False | None | None | False | None | False | 11066.0 | 0 |
3786529 | 143048 | None | NMH94 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 150 W | Each | 16175.5 | 16175.5 | 2.0 | False | None | None | False | None | False | 32351.0 | 0 |
3786530 | 143048 | None | NMH95 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 100 A | Each | 9387.4 | 9387.4 | 1.0 | False | None | None | False | None | False | 9387.4 | 0 |
3786531 | 143048 | None | NMH96 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 250 A | Each | 23963.5 | 23963.5 | 1.0 | False | None | None | False | None | False | 23963.5 | 0 |
3786532 | 143048 | None | NMH97 | Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 A | Each | 2483.8 | 2483.8 | 1.0 | False | None | None | False | None | False | 2483.8 | 0 |
3786533 | 143048 | None | NMH98 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100percentage lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.THREE POLE 100A 25kA | Each | 6694.6 | 6694.6 | 6.0 | False | None | None | False | None | False | 40167.6 | 0 |
3786534 | 143048 | None | NMH99 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100percentage lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250 A 36 kA | Each | 25899.5 | 25899.5 | 1.0 | False | None | None | False | None | False | 25899.5 | 0 |
3786535 | 143048 | None | NMH100 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCBs as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCBs as outgoings confirming to IS/IEC 60898 - 24 Way | Each | 11361.9 | 11361.9 | 2.0 | False | None | None | False | None | False | 22723.8 | 0 |
3786536 | 143048 | None | NMH101 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCBs as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCBs as outgoings confirming to IS/IEC 60898 - 28 Way | Each | 13865.5 | 13865.5 | 1.0 | False | None | None | False | None | False | 13865.5 | 0 |
3786537 | 143048 | None | NMH102 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 456.5 | 456.5 | 60.0 | False | None | None | False | None | False | 27390.0 | 0 |
3786538 | 143048 | None | NMH103 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP | Each | 812.9 | 812.9 | 16.0 | False | None | None | False | None | False | 13006.4 | 0 |
3786539 | 143048 | None | NMH104 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63A TPN | Each | 3396.8 | 3396.8 | 6.0 | False | None | None | False | None | False | 20380.8 | 0 |
3786540 | 143048 | None | NMH105 | Supplying and fixing regular MCB distribution boards on wall/Wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure Double Door - 12 Way SP & N | Each | 2561.9 | 2561.9 | 2.0 | False | None | None | False | None | False | 5123.8 | 0 |
3786541 | 143048 | None | NMH106 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure Double Door - 16 Way SP & N | Each | 3198.8 | 3198.8 | 2.0 | False | None | None | False | None | False | 6397.6 | 0 |
3786542 | 143048 | None | NMH107 | Supplying, fixing and wiring 0 to 30V Direct Reading DC Voltmeter/Ammeter | Each | 759.0 | 759.0 | 2.0 | False | None | None | False | None | False | 1518.0 | 0 |
3786543 | 143048 | None | NMH108 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 220.0 | 220.0 | 1.0 | False | None | None | False | None | False | 220.0 | 0 |
3786544 | 143048 | None | NMH109 | Supplying, fixing and wiring rotary selector switch suitable for Voltmete | Each | 176.0 | 176.0 | 1.0 | False | None | None | False | None | False | 176.0 | 0 |
3786545 | 143048 | None | NMH110 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 10246.5 | 10246.5 | 1.0 | False | None | None | False | None | False | 10246.5 | 0 |
3786546 | 143048 | None | NMH111 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer | Each | 924.0 | 924.0 | 3.0 | False | None | None | False | None | False | 2772.0 | 0 |
3786547 | 143048 | None | NMH112 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 566.5 | 566.5 | 12.0 | False | None | None | False | None | False | 6798.0 | 0 |
3786548 | 143048 | None | NMH113 | Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic FRP DMC insulator which are mounted on powder coated 40 6mm M S flat frame work in existing panel board The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts nuts and washers etc complete 100 A 4 30 6 mm Aluminium Strips | m | 2711.5 | 2711.5 | 4.0 | False | None | None | False | None | False | 10846.0 | 0 |
3786549 | 143048 | None | NMH117 | Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In & Loop- Out terminals for 10 mm2 /25 mm2 3.5 C AI/Ar/Cu/Ar Cable and branch out 2.5 mm2 2 core AI/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets. 200 mm x 200 mm x 98 mm | Each | 2530.0 | 2530.0 | 1.0 | False | None | None | False | None | False | 2530.0 | 0 |
3786550 | 143048 | None | NMH118 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete 12" Sweep (300 mm) | Each | 3265.9 | 3265.9 | 4.0 | False | None | None | False | None | False | 13063.6 | 0 |
3786551 | 143048 | None | NMH119 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete 15" Sweep (450 mm) | Each | 4890.6 | 4890.6 | 6.0 | False | None | None | False | None | False | 29343.6 | 0 |
3786552 | 143048 | None | NMH120 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 percentage, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10percentage RPM, Rated air delivery 210 +/- 10percentage Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans 56" Sweep 5 Star (1400 mm) | Each | 4129.4 | 4129.4 | 24.0 | False | None | None | False | None | False | 99105.6 | 0 |
3786553 | 143048 | None | NMH121 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.5 Star With Fibre body 25 L | Each | 13121.9 | 13121.9 | 2.0 | False | None | None | False | None | False | 26243.8 | 0 |
3786554 | 143048 | None | NMH122 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hrat Lumen Maintenance of 70percentage, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factorgreater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. ULapproved MCPCB LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Post Top Lantern with 35/40 W | Each | 10584.2 | 10584.2 | 4.0 | False | None | None | False | None | False | 42336.8 | 0 |
3786555 | 143048 | None | NMH123 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 70W | Each | 7444.8 | 7444.8 | 8.0 | False | None | None | False | None | False | 59558.4 | 0 |
3786556 | 143048 | None | NMH124 | Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70percentage. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldlesser than 5percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 2x2 40-42W | No | 5347.1 | 5347.1 | 18.0 | False | None | None | False | None | False | 96247.8 | 0 |
3786557 | 143048 | None | NMH125 | Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI greater than 80. Power Input: 220-240Vat 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4 - 36/40 W | Each | 1395.9 | 1395.9 | 12.0 | False | None | None | False | None | False | 16750.8 | 0 |
3786558 | 143048 | None | NMH126 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Nos | 4681.6 | 4681.6 | 4.0 | False | None | None | False | None | False | 18726.4 | 0 |
3786559 | 143048 | None | NMH127 | GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm Copper strip | m | 627.0 | 627.0 | 48.0 | False | None | None | False | None | False | 30096.0 | 0 |
3786560 | 143048 | None | NMH128 | 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.150 x 50 mm | m | 509.3 | 509.3 | 30.0 | False | None | None | False | None | False | 15279.0 | 0 |
3786561 | 143048 | None | NMH129 | 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.300 x 50 mm | m | 645.7 | 645.7 | 30.0 | False | None | None | False | None | False | 19371.0 | 0 |
3786562 | 143048 | None | NMH130 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and S hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 346.5 | 346.5 | 24.0 | False | None | None | False | None | False | 8316.0 | 0 |
3786563 | 143048 | None | NMH131 | Extra length of GI pipe of class B 19mm dia for down rod | m | 216.7 | 216.7 | 35.0 | False | None | None | False | None | False | 7584.5 | 0 |
3786564 | 143048 | None | NMH114 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 into 30 into 10 mm Aluminium Strips | Rmtr | 3778.5 | 3778.5 | 8.0 | False | None | None | False | None | False | 30228.0 | 0 |
3786565 | 143048 | None | NMH115 | Supplying and fixing angle iron frame work fabricated out of M S angle iron and M S Flat with bolts washers etc and painted with 2 coats of red oxide and then two coats of approved paint 50 50 6 mm | m | 434.5 | 434.5 | 18.0 | False | None | None | False | None | False | 7821.0 | 0 |
3786566 | 143048 | None | NMH116 | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete 16 SWG. | Sq CM | 0.47 | 0.47 | 120000.0 | False | None | None | False | None | False | 56400.0 | 0 |