| 3793271 | 143672 | None | code01 | Earth work Excavation for foundation of structure upto 3mtr by mechanical means as per drawing technical specification inculding setting out providing shoring, strutting and fencing removla of strumps and other deleterou matter dressing of sides and bottom filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.0KM lead including cost of labour CM SR 2021-22 Page No.8 Vol-1 Item No.1.14.1 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 75.19 | 75.19 | 24.38 | False | None | None | False | None | False | 1833.1322 | 0 |
| 3793272 | 143672 | None | code02 | Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately) CM SR 2021-22 P.No.15 Volume -1 Item No.2.1.3 Mix 1:3:6 (M10) - 40mm DS ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 5720.62 | 5720.62 | 2.08 | False | None | None | False | None | False | 11898.8896 | 0 |
| 3793273 | 143672 | None | code03 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) I.No. 2.2.1.1 P.No.15 Volume-1 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 6610.9 | 6610.9 | 2.36 | False | None | None | False | None | False | 15601.724 | 0 |
| 3793274 | 143672 | None | code04 | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) I.No. 2.2.2.1 P.No.15 Volume-1 CM SR 2021-22 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 6774.2 | 6774.2 | 0.49 | False | None | None | False | None | False | 3319.358 | 0 |
| 3793275 | 143672 | None | code05 | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) I.No. 2.5.2 P.No.17 Volume-1 CM SR 2021-22 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 7008.7 | 7008.7 | 2.09 | False | None | None | False | None | False | 14648.183 | 0 |
| 3793276 | 143672 | None | code06 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) P.No. 17 Vol-1 Item No. 2.5.2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 7645.8 | 7645.8 | 3.48 | False | None | None | False | None | False | 26607.384 | 0 |
| 3793277 | 143672 | None | code07 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) P.No. 17 Vol-1 Item No. 2.5.2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 7423.2 | 7423.2 | 6.79 | False | None | None | False | None | False | 50403.528 | 0 |
| 3793278 | 143672 | None | code08 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or
more Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position, binding and anchoring to adjacent
members whereever necessary complete as per Design including cost
of material, labour, usage charges complete as per specifications. (The
laps and wastages shall not be measured separately).Item No. 11.32 P.No.81 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Kg | 94.76 | 94.76 | 1730.9 | False | None | None | False | None | False | 164020.084 | 0 |
| 3793279 | 143672 | None | code09 | Providing Random rubble masonry with hard stone in foundation
and plinth including levelling up with cement concrete 1:6:12 (1 cement
: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto
plinth level with : I.No. 5.1.1 P.No.9 Vol-2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 4892.5 | 4892.5 | 18.22 | False | None | None | False | None | False | 89141.35 | 0 |
| 3793280 | 143672 | None | code10 | Filling available excavated earth (excluding rock) in trench plinth sides of foundation and othr Similar works etc in layer not exceeding 20cm in depth consolidating each disposal layer by ramming and watering lead up to 50m and lift up to 1.5m. CM SR 2021-22 P.No.115 Vol-1 Item No.1.9 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 210.12 | 210.12 | 7.22 | False | None | None | False | None | False | 1517.0664 | 0 |
| 3793281 | 143672 | None | code11 | Providing Brick work with common burnt clay Non Modular bricksof class designation 3.5 in foundation and plinth in Cement mortar1:6 (1 cement : 6 coarse sand) including cost of all materials, labour,scaffolding and usage charges of machinery & other incidental chargescomplete as per the direction of engineer incharge of work. Item No.6.4 P.No. 13 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 7635.39 | 7635.39 | 20.08 | False | None | None | False | None | False | 153318.6312 | 0 |
| 3793282 | 143672 | None | code12 | Providing 20mm plaster mix 1:4 (1 Cement 4 fine sand) to brick /stone masonry including rounding off corners whereas required smooth rendering providng and remvoing scaffolding including cost material and laboru. SR 2021-22 / P.No.41 Vol-2 Item No. 8.3.1 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 307.97 | 307.97 | 103.81 | False | None | None | False | None | False | 31970.3657 | 0 |
| 3793283 | 143672 | None | code13 | Providing 15mm thick plaster on the rough side of single or half brick wall of mix 1:4 (1 cement 4 fine sand) inclduing rounding off corner wherever required smooth rendering Providing and removing scafoling including cost of materials labour curring complete as per specification and as per direction of Engineer incharge CM SR 2021-22 P.No. 41 Vol-2 Item No. 8.2.1 Upto 3.5M ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 255.44 | 255.44 | 141.7 | False | None | None | False | None | False | 36195.848 | 0 |
| 3793284 | 143672 | None | code14 | Providing 12mm cement plaster finished with a flooting coat of neat cement of mix 1:3 (1 cement 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering providng and removing scaffolding including cost of materials labour curring complete as per specification as per direction of Engineer incharge. CMSR 2021-22 P.No.41 Vol-2 I.No. 8.4.1 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 282.22 | 282.22 | 25.14 | False | None | None | False | None | False | 7095.0108 | 0 |
| 3793285 | 143672 | None | code15 | Providing and laying vitrified floor tiles in different sizes (thicknessto be specified by the manufacturer) with water absorption less than0.08% and conforming to IS: 15622, of approved make, in all coloursand shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarsesand), jointing with grey cement slurry @ 3.3 kg/ m2 including groutingthe joints with white cement and matching pigments etc., complete.. CM SR 2021-22 P.No. 63 I.No. 9.21.2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 1182.44 | 1182.44 | 25.14 | False | None | None | False | None | False | 29726.5416 | 0 |
| 3793286 | 143672 | None | code16 | Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to steel windows by welding Item No. 11.34(A) P.No. 85 Vol-2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Kg | 134.93 | 134.93 | 62.37 | False | None | None | False | None | False | 8415.5841 | 0 |
| 3793287 | 143672 | None | code17 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conformingto IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matchingpigments etc., complete. Item No. 9.11 P.No.60 Vol-2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 784.86 | 784.86 | 53.84 | False | None | None | False | None | False | 42256.8624 | 0 |
| 3793288 | 143672 | None | code18 | Providing & fixing of 2track x 2panel sliding windows made out of multichambered UPVC (Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer)and lead free, gaskets -grey colour having isolated drainage andreinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 50mm width x 42mmheightwith reinforcement of 1mm thickness and Sash with overall size of 31mmX 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm forthe sash. Coextruded Glazing bead for fixing of glass shall be of size21.5mm x 9.5 mm. Windows shall be provided with 5mm plain floatglass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.80.2 mm. Maximumpossible size 1519mm x 1519mm. (The cost is inclusive of all fixturesand separate charges for minor T&P's shall not be made) . Item No. 12.86 P.No.108 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 6017.26 | 6017.26 | 2.16 | False | None | None | False | None | False | 12997.2816 | 0 |
| 3793289 | 143672 | None | code19 | Providing Mathi / Nandi Wood frame of doors windows clerestory windows ventilators and other frame wrought framed or assembled including CMSR 2021-22 Pno. 100 Vol-2 Item no. 12.12 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 77604.32 | 77604.32 | 0.04 | False | None | None | False | None | False | 3104.1728 | 0 |
| 3793290 | 143672 | None | code20 | Providing and fixing in position fully panelled matti / Nandi wood shutter for doors with stiler and rails of 30mm thick with bottom and lock rails 180mm wide top rail and side 100mm wide as per drawing and panels of 25mm thick including cost of material, labour charge CMSR 2021-22 P.No.101 Vol-02 Item No. 12.21 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 3920.18 | 3920.18 | 1.68 | False | None | None | False | None | False | 6585.9024 | 0 |
| 3793291 | 143672 | None | code21 | Providing & fixing 30mm thick factory made rigid foam Panelled DoorShutters made from M.S. tube of 19 gauge thickness, size 19x19mm forstiles and 15x15mm for top & bottom rails, covered with heat mouldedPVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles &5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom railon either side & 5mm thick 20mm wide PVC sheet as gap insert for toprail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S.Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading oneither side & joined together with solvent cement adhesive etc., Complete
as per manufacturers specification & direction of Engineer-in-chargefixed to frames with 3 nos of 75 mm Aluminium hinges. CMSR 2021-22 VOL-2 P.No. 106 Item No.12.55 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 3917.09 | 3917.09 | 6.3 | False | None | None | False | None | False | 24677.667 | 0 |
| 3793292 | 143672 | None | code22 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required: Item No. 14.1 P.No.121 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Sqm | 4373.38 | 4373.38 | 4.0 | False | None | None | False | None | False | 17493.52 | 0 |
| 3793293 | 143672 | None | code23 | Construction of Embankment by excavating the available approved
Gravel/Murrum deposited at a place or borrow pits during or prior
excavation with all lifts and lead, transportation to site, spreading,
grading to required slope and compacting to meet the requirement
complete as per specifications, including cost of labour,rolling,water,all
materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5
per m for every 1.50 m height or part there off, Deduct 5% per m if rollers are not used and tamping is done manually Add 8 per m for works under foul & sullage situation (PWD SR 2021-22 Vol-1 It. No-1.8, P.No-7) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 414.06 | 414.06 | 19.92 | False | None | None | False | None | False | 8248.0752 | 0 |
| 3793294 | 143672 | None | code24 | Earth work excavation for pipeline trenches in all kinds of soils bymechanical means above 600 mm trench width as per drawing andtechnical specifications, including setting out, construction of shoring,strutting, barricading, caution lights, bracing, using sight rails & boningrods at every 100 mm whevere necessary as directed, removal ofstumps and other deleterious matter, dressing of sides and levellingthe bottom of trench to the extent required , utilising the availableexcavated earth locally for the work etc., and all other appurtenancescomplete in the following strata. All kinds of soils. Depth upto 1.50 m (CM SR 20201-22 P.No. 10 , vol-1 It.No-1.17.1 ) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Cum | 194.0 | 194.0 | 4.05 | False | None | None | False | None | False | 785.7 | 0 |
| 3793295 | 143672 | None | code25 | Supplying HDPE Pipe conforming to IS 4984:1995 with latest ammendment and conveying to work site including loading and unloading at both destination and rolling, lowering in to trenches laying true to line and jointing of pipes and specials including ancasing the pipe to arrond to a depth not less than 15 cms with soft graval or selected earth available from the excavation etc, complete giving hydraulic test as per relevant ISS with all lead and lift including testing & commisioning. The rate is exclusive of required specials & fittings etc complte (contractor will make his own arrangement for procurring water Testing) KWUSDB SR 215-16, P.No-123, It No-50 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | m | 349.0 | 349.0 | 20.0 | False | None | None | False | None | False | 6980.0 | 0 |
| 3793296 | 143672 | None | code26 | Providing & Fixing of Submarsible mono Block three phase/ Equivalent pump 1.5 HP ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Nos | 11276.0 | 11276.0 | 1.0 | False | None | None | False | None | False | 11276.0 | 0 |
| 3793297 | 143672 | None | code27 | Providing & Fixing chorinated poly veny chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fitting this included jointing at pipes and fitting with one step solvent cement, trenching refilling & testing at joints complete as per directions of Engineer incharges of work extarnal ware 32 mm nominal dia pipes( SR 2021-22, P.No-8, It No-13.33.4 Vol-2) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | m | 358.0 | 358.0 | 20.0 | False | None | None | False | None | False | 7160.0 | 0 |
| 3793298 | 143672 | None | code28 | Providing & Fixing chorinated poly veny chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fitting this included jointing at pipes and fitting with one step solvent cement, trenching refilling & testing at joints complete as per directions of Engineer incharges of work extarnal ware 20mm nominal dia pipes( SR 2021-22, P.No-8, It No-13.32.2 Vol-2) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | m | 373.0 | 373.0 | 20.0 | False | None | None | False | None | False | 7460.0 | 0 |
| 3793299 | 143672 | None | code29 | Cutting hole upto 30X30 CM in wall including making good the same with common burnt clay F.P.S. (non Modular) Brick (SR 2021-22 P.No-119, It No-13.36, Vol-2) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | m | 266.0 | 266.0 | 10.0 | False | None | None | False | None | False | 2660.0 | 0 |
| 3793300 | 143672 | None | code30 | Providing & Fixing brass bib cock of approved quality 20mm nominal bore (SR 2021-22 P.No-115,It No-13.2.2, Vol-1) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Each | 345.0 | 345.0 | 20.0 | False | None | None | False | None | False | 6900.0 | 0 |
| 3793301 | 143672 | None | code31 | Providing & Fixing Brass full way valve gate with C.I Wheel of approved quality (screwed end)32mm nominal bore (SR 2021-22 P.No115, It.No-13.4.2 Vol-1) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Each | 577.0 | 577.0 | 2.0 | False | None | None | False | None | False | 1154.0 | 0 |
| 3793302 | 143672 | None | code32 | Providing & Fixing C.I Nahani trap at approved make confirming ISI Specification and construction of cistern in M-15 as per direction (Rate is Inclusive of cost of materials and fixturs and conveyance of materials to spot 10cms X 7.5 cms (North Zone SR 2018-19 P.No-90,It .No-12.113.1) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Each | 250.0 | 250.0 | 20.0 | False | None | None | False | None | False | 5000.0 | 0 |
| 3793303 | 143672 | None | code33 | Constructing brick masonry inspection chamber 450x300mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 450x300mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 450x300mm (SR 2018-19, P.No-75. It No-11.50.3) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Nos | 5552.0 | 5552.0 | 2.0 | False | None | None | False | None | False | 11104.0 | 0 |
| 3793304 | 143672 | None | code34 | KSRB 12-7.1 : Making connection of drain or sewer line of size 100 to 230mm external dia with existing manhole including breaking into and making good the walls, floors with cement concrete M 15 with 20mm and downsize granite metal, cement plastered on both sides of mix 1:3, finished with a floating coat of neat cement, and making necessary channels for the drain, including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS (SR 2018-19, P.No-75. It No-11.47) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Nos | 2701.0 | 2701.0 | 1.0 | False | None | None | False | None | False | 2701.0 | 0 |
| 3793305 | 143672 | None | code35 | Providing & Placing on terrace (at all floor lerels) Polyethylene water storage tanks IS 12701 marked with cover and suitable looking arrangement making necessary holes for Inlet outlet, and over flow pipe but with out fittings and the base support for tank (SR 2021-22 P.No-128 It.No-13.34 Vol-2) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | Ltr | 8.0 | 8.0 | 1000.0 | False | None | None | False | None | False | 8000.0 | 0 |
| 3793306 | 143672 | None | code36 | Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and testing complete as per specifications. - 110mm dia (SR 2016-17, P.No-88. It No-12.116.1) ---- CLASS-3 PWD VALID CONTRACTOR LICENCE | m | 434.0 | 434.0 | 20.0 | False | None | None | False | None | False | 8680.0 | 0 |