1723891026000 | 0 | None | None | Other Works | Construction of 68 Nos. Ground Water Recharge pits at different locations in the premises of KPTCL and BBMP schools at Bengaluru for compliance to SEIAA conditions for obtaining Environmental Clearance (EC) in respect of construction of Office Complex (Indhana Bhavana) at Ananda Rao Circle, Bengaluru. | 5462761.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3797101 | 143965 | None | code01 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge,
upto 90 metre depth below ground level All types of soil-300 mm dia (3m x 34 Nos.) | Mtr | 707.75 | 707.75 | 102.0 | False | None | None | False | None | False | 72190.5 | 0 | 3797102 | 143965 | None | code02 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge,
upto 90 metre depth below ground level Rocky strata including Boulders-300 mm dia (3m x 34 Nos.) | Mtr | 1695.1 | 1695.1 | 102.0 | False | None | None | False | None | False | 172900.2 | 0 | 3797103 | 143965 | None | code03 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
200 mm nominal size dia | Mtr | 1255.7 | 1255.7 | 204.0 | False | None | None | False | None | False | 256162.8 | 0 | 3797104 | 143965 | None | code04 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | CUBIC METER | 1509.8 | 1509.8 | 25.0 | False | None | None | False | None | False | 37745.0 | 0 | 3797105 | 143965 | None | code05 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | CUBIC METER | 1538.25 | 1538.25 | 25.0 | False | None | None | False | None | False | 38456.25 | 0 | 3797106 | 143965 | None | code06 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | CUBIC METER | 1538.25 | 1538.25 | 25.0 | False | None | None | False | None | False | 38456.25 | 0 | 3797107 | 143965 | None | code07 | Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge | CUBIC METER | 2024.5 | 2024.5 | 9.0 | False | None | None | False | None | False | 18220.5 | 0 | 3797108 | 143965 | None | code08 | Providing and fixing factory made precast RCC perforated drain covers,having concrete of strength not less than M-25, of size 1200 dia x50mm thick, reinforced with 8 mm dia T.M.T. hoop bars at 120 C/c bothways, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50mm x 1.6 mm complete, all as per direction of Engineer-in-charge | Each | 1399.95 | 1399.95 | 68.0 | False | None | None | False | None | False | 95196.6 | 0 | 3797109 | 143965 | None | code09 | Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches,foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m. | CUBIC METER | 314.11 | 314.11 | 440.0 | False | None | None | False | None | False | 138208.4 | 0 | 3797110 | 143965 | None | code10 | Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches,foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3m. | CUBIC METER | 336.18 | 336.18 | 112.0 | False | None | None | False | None | False | 37652.16 | 0 | 3797111 | 143965 | None | code11 | Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and
jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his
own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry
RCC NP3 Class pipe of 900 mm dia | Mtr | 6295.3 | 6295.3 | 150.0 | False | None | None | False | None | False | 944295.0 | 0 | 3797112 | 143965 | None | code12 | Providing and fixing 100mm sand cast iron grating for rain water Harvesting pits | Each | 53.25 | 53.25 | 136.0 | False | None | None | False | None | False | 7242.0 | 0 | 3797113 | 143965 | None | code13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
100 mm nominal dia Pipes | Mtr | 3271.7 | 3271.7 | 680.0 | False | None | None | False | None | False | 2224756.0 | 0 | 3797114 | 143965 | None | code14 | Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
18.37.1 With common burnt clay F.P.S.(non modular) bricks of class -designation 7.5 | Each | 9698.55 | 9698.55 | 68.0 | False | None | None | False | None | False | 659501.4 | 0 | 3797115 | 143965 | None | code15 | Removal of Unserviceable Soil with Disposal includes cost of excavation, loading, undloading, transportation and spreading with a lead of 10Kms. The work shall be carried out as per the directions of engineer-in-charge of works. | CUBIC METER | 755.44 | 755.44 | 570.0 | False | None | None | False | None | False | 430600.8 | 0 | 3797116 | 143965 | None | code16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | CUBIC METER | 345.26 | 345.26 | 58.0 | False | None | None | False | None | False | 20025.08 | 0 | 3797117 | 143965 | None | code17 | Clearing Grass and Removal of Rubbish & dumping to outside periphery by manual means | Sqm | 4.8 | 4.8 | 612.0 | False | None | None | False | None | False | 2937.6 | 0 | 3797118 | 143965 | None | code18 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate
disposal area as per direction of Engineer-in-charge. | CUBIC METER | 3148.95 | 3148.95 | 68.0 | False | None | None | False | None | False | 214128.6 | 0 | 3797119 | 143965 | None | code19 | Design & drawing of all the subject work including layout , other services drawings as per requirement and directions, submitting elevation, sectional, 3D, drawings developed using auto cad software & 3D max , other softwares and submitting six copies of colour drawings for approval, with suitable softwares for useage and liaison with KPTCL to get drawing approvals. apply for government statutory approvals/ clearences, liaison with all government statutory bodies such as Fire & emergency department, Pollution control boards, BBMP, Forest, SEIAA etc., [statutory fee required for approvals/clearences, will be paid by the Employer], obtaining all necessary approval/clearences for government statutory bodies , development all the drawings using above items and are to be submitted for approval. submision as built drawings after completion of works-all 6 copies | Lot | 54086.8 | 54086.8 | 1.0 | False | None | None | False | None | False | 54086.8 | 0 |
|