3779444 | 142689 | None | PRED1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column | Cum | 11904.17 | 11904.17 | 3.43 | False | None | None | False | None | False | 40831.3031 | 0 |
3779445 | 142689 | None | PRED2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For lintel | Cum | 11208.02 | 11208.02 | 1.47 | False | None | None | False | None | False | 16475.7894 | 0 |
3779446 | 142689 | None | PRED3 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Chejja | Cum | 10163.79 | 10163.79 | 0.54 | False | None | None | False | None | False | 5488.4466 | 0 |
3779447 | 142689 | None | PRED4 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof beam | Cum | 11208.02 | 11208.02 | 3.68 | False | None | None | False | None | False | 41245.5136 | 0 |
3779448 | 142689 | None | PRED5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Slab | Cum | 10511.87 | 10511.87 | 10.7 | False | None | None | False | None | False | 112477.009 | 0 |
3779449 | 142689 | None | PRED6 | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) | Tonne | 94869.15 | 94869.15 | 1.66 | False | None | None | False | None | False | 157482.789 | 0 |
3779450 | 142689 | None | PRED7 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8451.12 | 8451.12 | 20.77 | False | None | None | False | None | False | 175529.7624 | 0 |
3779451 | 142689 | None | PRED8 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Sqm | 1124.13 | 1124.13 | 30.21 | False | None | None | False | None | False | 33959.9673 | 0 |
3779452 | 142689 | None | PRED9 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.. | Kg | 178.16 | 178.16 | 257.04 | False | None | None | False | None | False | 45794.2464 | 0 |
3779453 | 142689 | None | PRED10 | Providing 15 mm thick cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 388.14 | 388.14 | 176.28 | False | None | None | False | None | False | 68421.3192 | 0 |
3779454 | 142689 | None | PRED11 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 375.42 | 375.42 | 131.0 | False | None | None | False | None | False | 49180.02 | 0 |
3779455 | 142689 | None | PRED12 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 500x500 mm | Sqm | 1406.22 | 1406.22 | 52.94 | False | None | None | False | None | False | 74445.2868 | 0 |
3779456 | 142689 | None | PRED13 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. | Kg | 67.87 | 67.87 | 10.7 | False | None | None | False | None | False | 726.209 | 0 |
3779457 | 142689 | None | PRED14 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.56 | 167.56 | 238.13 | False | None | None | False | None | False | 39901.0628 | 0 |
3779458 | 142689 | None | PRED15 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.05 | 106.05 | 238.13 | False | None | None | False | None | False | 25253.6865 | 0 |
3779459 | 142689 | None | PRED16 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 186.35 | 186.35 | 131.0 | False | None | None | False | None | False | 24411.85 | 0 |
3779460 | 142689 | None | PRED17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 121.96 | 121.96 | 12.24 | False | None | None | False | None | False | 1492.7904 | 0 |
3779461 | 142689 | None | PRED18 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5326.89 | 5326.89 | 11.54 | False | None | None | False | None | False | 61472.3106 | 0 |
3779462 | 142689 | None | PRED19 | OPEN CONDUIT SYSTEM: Supplying heavy guage PVC conduit pipe 25mm dia 2 mm thick conforming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy guage saddles at an interval of 700mm using NF screws 25MM DIA 2MM THICK | Mtr | 78.0 | 78.0 | 30.0 | False | None | None | False | None | False | 2340.0 | 0 |
3779463 | 142689 | None | PRED20 | Supplying heavy guage PVC conduit Pipe ….dia….mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J Hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25MM DIA 2MM THICK | Mtr | 79.0 | 79.0 | 20.0 | False | None | None | False | None | False | 1580.0 | 0 |
3779464 | 142689 | None | PRED21 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., complete 75 X 75 X 65MM | No | 106.0 | 106.0 | 2.0 | False | None | None | False | None | False | 212.0 | 0 |
3779465 | 142689 | None | PRED22 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., complete 100 X 75 X 65MM | No | 118.0 | 118.0 | 5.0 | False | None | None | False | None | False | 590.0 | 0 |
3779466 | 142689 | None | PRED23 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., complete 135 X 75 X 65MM | No | 139.0 | 139.0 | 6.0 | False | None | None | False | None | False | 834.0 | 0 |
3779467 | 142689 | None | PRED24 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., complete 180 X 90 X 65MM | No | 161.0 | 161.0 | 4.0 | False | None | None | False | None | False | 644.0 | 0 |
3779468 | 142689 | None | PRED25 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., complete 200 X 90 X 65MM | No | 179.0 | 179.0 | 2.0 | False | None | None | False | None | False | 358.0 | 0 |
3779469 | 142689 | None | PRED26 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., complete 135 X 160 X 65MM | No | 215.0 | 215.0 | 2.0 | False | None | None | False | None | False | 430.0 | 0 |
3779470 | 142689 | None | PRED27 | Supplying and fixing PVC / Metal conduit Deep Junction Box 25MM DEEP JUNCTION BOX | No | 56.0 | 56.0 | 6.0 | False | None | None | False | None | False | 336.0 | 0 |
3779471 | 142689 | None | PRED28 | Supplying and fixing S Hook made out of 14mm dia MS Rod | No | 52.0 | 52.0 | 6.0 | False | None | None | False | None | False | 312.0 | 0 |
3779472 | 142689 | None | PRED29 | Supplying and fixing metal fan box with round hook | No | 117.0 | 117.0 | 6.0 | False | None | None | False | None | False | 702.0 | 0 |
3779473 | 142689 | None | PRED30 | POINT WIRING USING COPPER WIRE WITH SWITCH: Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 2 x 1.5sqmm (Phase and Neutral) & 1 x 1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet SHORT POINT UPTO 3 MTR FROM TAPPING POINT TO OUT LET VIA SWITCH | No | 285.0 | 285.0 | 6.0 | False | None | None | False | None | False | 1710.0 | 0 |
3779474 | 142689 | None | PRED31 | POINT WIRING USING COPPER WIRE WITH SWITCH: Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 2 x 1.5sqmm (Phase and Neutral) & 1 x 1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet MEDIUM POINT ABOVE 3 MTR UPTO 6MTR FROM TAPPING POINT TO OUTLET VIA SWITCH | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 |
3779475 | 142689 | None | PRED32 | POINT WIRING USING COPPER WIRE WITH SWITCH: Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 2 x 1.5sqmm (Phase and Neutral) & 1 x 1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet LONG POINT ABOVE 6 MTR UPTO 10 MTR FROM TAPPING POINT TO OUT LET VIA SWITCH | No | 570.0 | 570.0 | 3.0 | False | None | None | False | None | False | 1710.0 | 0 |
3779476 | 142689 | None | PRED33 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 691 confirming to latest amendments 1 MM2 | Mtr | 19.0 | 19.0 | 40.0 | False | None | None | False | None | False | 760.0 | 0 |
3779477 | 142689 | None | PRED34 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 691 confirming to latest amendments 1.5MM2 | Mtr | 26.0 | 26.0 | 80.0 | False | None | None | False | None | False | 2080.0 | 0 |
3779478 | 142689 | None | PRED35 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 691 confirming to latest amendments 2.5MM2 | Mtr | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 |
3779479 | 142689 | None | PRED36 | Supplying 6A Flush type socket and 65 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 WAY | No | 128.0 | 128.0 | 8.0 | False | None | None | False | None | False | 1024.0 | 0 |
3779480 | 142689 | None | PRED37 | Supplying 6A Flush type socket and 65 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 WAY | No | 147.0 | 147.0 | 10.0 | False | None | None | False | None | False | 1470.0 | 0 |
3779481 | 142689 | None | PRED38 | Supplying and fixing superior quality modular sitch mounting polycarbonate plate with necessary supporting back plate with required No. of machine screws, bolts nuts etc, complete on the existing metal/PVC box 1 TO 2 MODULE | No | 137.0 | 137.0 | 4.0 | False | None | None | False | None | False | 548.0 | 0 |
3779482 | 142689 | None | PRED39 | Supplying and fixing superior quality modular sitch mounting polycarbonate plate with necessary supporting back plate with required No. of machine screws, bolts nuts etc, complete on the existing metal/PVC box3 MODULE | No | 161.0 | 161.0 | 4.0 | False | None | None | False | None | False | 644.0 | 0 |
3779483 | 142689 | None | PRED40 | Supplying and fixing superior quality modular sitch mounting polycarbonate plate with necessary supporting back plate with required No. of machine screws, bolts nuts etc, complete on the existing metal/PVC box 4 MODULE | No | 175.0 | 175.0 | 6.0 | False | None | None | False | None | False | 1050.0 | 0 |
3779484 | 142689 | None | PRED41 | Supplying and fixing superior quality modular sitch mounting polycarbonate plate with necessary supporting back plate with required No. of machine screws, bolts nuts etc, complete on the existing metal/PVC box 6 MODULE | No | 234.0 | 234.0 | 6.0 | False | None | None | False | None | False | 1404.0 | 0 |
3779485 | 142689 | None | PRED42 | Supplying and fixing superior quality modular sitch mounting polycarbonate plate with necessary supporting back plate with required No. of machine screws, bolts nuts etc, complete on the existing metal/PVC box 8 MODULE | No | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 |
3779486 | 142689 | None | PRED43 | Supplying and fixing superior quality modular sitch mounting polycarbonate plate with necessary supporting back plate with required No. of machine screws, bolts nuts etc, complete on the existing metal/PVC box 10-12 MODULE | No | 344.0 | 344.0 | 6.0 | False | None | None | False | None | False | 2064.0 | 0 |
3779487 | 142689 | None | PRED44 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A ONE WAY SWITCH | No | 102.0 | 102.0 | 20.0 | False | None | None | False | None | False | 2040.0 | 0 |
3779488 | 142689 | None | PRED45 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A TWO WAY SWITCH | No | 166.0 | 166.0 | 4.0 | False | None | None | False | None | False | 664.0 | 0 |
3779489 | 142689 | None | PRED46 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A THREE WAY SOCKET | No | 171.0 | 171.0 | 5.0 | False | None | None | False | None | False | 855.0 | 0 |
3779490 | 142689 | None | PRED47 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 STEPPED FAN REGTULATOR TWO MODULE | No | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 |
3779491 | 142689 | None | PRED48 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 400W DIMMER | No | 276.0 | 276.0 | 4.0 | False | None | None | False | None | False | 1104.0 | 0 |
3779492 | 142689 | None | PRED49 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP SWITCH | No | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 |
3779493 | 142689 | None | PRED50 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A UNIVERSAL SOCKET | No | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 |
3779494 | 142689 | None | PRED51 | Supplying and fixing MCB on existing MCB distribution boards using necessary fixing materials and C curve indicator ON/OFF energy cross 3 with short circuit breaking capacity of 10K and complete wiring as reuired confirming to IEC 60898 6-32 A DP | No | 739.0 | 739.0 | 4.0 | False | None | None | False | None | False | 2956.0 | 0 |
3779495 | 142689 | None | PRED52 | Spplying and fixing regular MCB distribution on wall/wood board / flush mounting using reuired clamp bolts, nuts with provision for fixing sutiable type capacity MCB’s single phase/3 phase/single door with powder coated painting made out of 14 SWG MS enclosures | No | 1854.0 | 1854.0 | 2.0 | False | None | None | False | None | False | 3708.0 | 0 |
3779496 | 142689 | None | PRED53 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230V 50 cycle single phase AC supply conforming to ISS 374 1979 and with double ball bearing system 58” SWEEP (1200MM) REGULARO MODEL | No | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 |
3779497 | 142689 | None | PRED54 | Supplying exhaust fan of 1440 RPM of 300mm (12”) size with bracket blades complete for light duty suitable to operate on 230V 50Hz AC supply | No | 1492.0 | 1492.0 | 2.0 | False | None | None | False | None | False | 2984.0 | 0 |
3779498 | 142689 | None | PRED55 | Fixing all types and all capacities of fluorescent / false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076” twin twisted PVC insulated wires, required No. of round blocks and clamps | No | 122.0 | 122.0 | 12.0 | False | None | None | False | None | False | 1464.0 | 0 |
3779499 | 142689 | None | PRED56 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 Amps ceiling rose with sufficient length of 23/0.0065” PVC insulated twin core wire | No | 492.0 | 492.0 | 2.0 | False | None | None | False | None | False | 984.0 | 0 |
3779500 | 142689 | None | PRED57 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 AMPS Ceiling rose, necessary length of 23/0.0076 Inch PVC insulated twin twisted copper wire and wiring | No | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 |
3779501 | 142689 | None | PRED58 | Supplying and fixing retrofit type PL LED Lamp 8-9 W LED linear source with CCT 6500 degree K CRI 70% efficacy 80 lumen per W, life 25000 burning hours and compliance to IS 10322/IEC 60598, LM 79 and LM 80, The LED are driven by HF electronic driver integrated in the system with PF 0.95, power loss should 5% of lamp wage. Short circuit and open circuit. THD less than 20% life as per LM 79. The operating input voltage should be between 130 to 275V. Tested by NABL / CPRI accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition | No | 702.0 | 702.0 | 12.0 | False | None | None | False | None | False | 8424.0 | 0 |
3779502 | 142689 | None | PRED59 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 |
3779503 | 142689 | None | PRED60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall | Mtr | 333.9 | 333.9 | 115.0 | False | None | None | False | None | False | 38398.5 | 0 |