createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723641529971
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd41500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose29-08-2024 16:30:00
tenderQueryClose28-08-2024 16:00:00
technicalBidOpen30-08-2024 17:00:00
publishedDate14-08-2024 19:28:13
publishedByPostTP_CO_MNGL
publishedByUserKPE13266 - SHABBIR IBRAHIM REVOORKAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonTown Panchayat Managuli
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448528099
tenderSupplierListNone
tenderSchedule
createdTs1723641530000
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT26715
titleConstruction of security room water sump and borewell at SWM site in Managuli
descriptionConstruction of security room water sump and borewell at SWM site in Managuli
categoryWORKS
categoryTextWorks
ecv1630142.68
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2253
locationNameDMA Town Panchayat Managooli
provisionalAmount1660000.0
groupOverheadTotal248665.83
fileNumberDUDC/TP/MNGL/SBM/2023-24/11
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17236415300000NoneNoneBuildingsConstruction of security room water sump and borewell at SWM site in Managuli1381476.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3781846142858Nonecode01Earth Work Excavation Mechanical :Earth work excavation for Foundation by mechanical means for all works & depth up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work ( In all kinds of soils Depth upto 3 m)Cum105.06105.0653.5FalseNoneNoneFalseNoneFalse5620.710
3781847142858Nonecode02Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. (Royalty shall be recovered @ Rs. 60.00/m3)Cum122.57122.5770.65FalseNoneNoneFalseNoneFalse8659.57050
3781848142858Nonecode03KSRB 2.10: Providing sand cement bed with all leads for all materials and lift of 1.5 m, machine mixed, laid in layers of 15cms. thick and well compacted for foundation, including curing cost of materials labour and HOM complete as per specifications.specification No. KBS 2.10.2-do-sand cement bed with 5% cement/CumCum3085.883085.8842.39FalseNoneNoneFalseNoneFalse130810.45320
3781849142858Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.672.27FalseNoneNoneFalseNoneFalse14002.88090
3781850142858Nonecode05Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators,including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregatesCum6475.616475.612.92FalseNoneNoneFalseNoneFalse18908.78120
3781851142858Nonecode06Form Work As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Footing. consider 8%Cum518.05518.052.92FalseNoneNoneFalseNoneFalse1512.7060
3781852142858Nonecode07Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinthlevel with :Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5779.335779.3313.83FalseNoneNoneFalseNoneFalse79928.13390
3781853142858Nonecode08Providing and laying in position Reinforced cement concrete for all superstructures of building, Road works, Water works, Irrigation works & superstructure works of bridges upto 3.50m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -do- M20 Design Mix Using 20mm nominal size graded crushed coarse aggregatesCum6828.96828.918.668FalseNoneNoneFalseNoneFalse127481.90520
3781854142858Nonecode09Form Work As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Staircase and other similar structures 50%Cum3237.83237.815.4279FalseNoneNoneFalseNoneFalse49952.454620
3781855142858Nonecode10Form Work As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For RCC Beams, Lintels & Troughs of Aqueducts 50%Cum3414.453414.453.57FalseNoneNoneFalseNoneFalse12189.58650
3781856142858Nonecode11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne81381.3381381.331.57FalseNoneNoneFalseNoneFalse127768.68810
3781857142858Nonecode12Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8217.348217.3422.58FalseNoneNoneFalseNoneFalse185547.53720
3781858142858Nonecode13Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm248.23248.23220.53FalseNoneNoneFalseNoneFalse54742.16190
3781859142858Nonecode14Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm91.6791.67220.53FalseNoneNoneFalseNoneFalse20215.98510
3781860142858Nonecode15Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).** Size of Tile 600x600 mmSqm1275.141275.1413.59FalseNoneNoneFalseNoneFalse17329.15260
3781861142858Nonecode16Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, FumeRed Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., completeSqm1108.281108.2825.7FalseNoneNoneFalseNoneFalse28482.7960
3781862142858Nonecode17Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.m215.27215.2739.29FalseNoneNoneFalseNoneFalse8457.95830
3781863142858Nonecode18Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance1mm), with wall thickness 2.0 mm 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitered and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-chargem198.0198.012.0FalseNoneNoneFalseNoneFalse2376.00
3781864142858Nonecode19Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour andapproved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.Sqm3300.123300.123.78FalseNoneNoneFalseNoneFalse12474.45360
3781865142858Nonecode20Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg123.6123.648.0FalseNoneNoneFalseNoneFalse5932.80
3781866142858Nonecode21Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm54.5954.59220.53FalseNoneNoneFalseNoneFalse12038.73270
3781867142858Nonecode22Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years lifeSqm162.74162.74220.53FalseNoneNoneFalseNoneFalse35889.05220
3781868142858Nonecode23Painting with oil type wood preservative of approved brand and manu facture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-Sqm41.241.2220.53FalseNoneNoneFalseNoneFalse9085.8360
3781869142858Nonecode24Varnishing with varnish of approved brand and manufacture: One coats with spar varnish including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer in-chargeSqm71.0771.0739.29FalseNoneNoneFalseNoneFalse2792.34030
3781870142858Nonecode25Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE ( Thermos Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-honeycomb structure inside in lieu of GI reinforcement.Sqm5173.695173.6914.4FalseNoneNoneFalseNoneFalse74501.1360
3781871142858Nonecode26Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 20mm diam223.51223.5110.0FalseNoneNoneFalseNoneFalse2235.10
3781872142858Nonecode27Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. 25mm diam304.88304.8815.0FalseNoneNoneFalseNoneFalse4573.20
3781873142858Nonecode28Providing and placing on terrace (at all floor levels), polyethylene water storage tanks IS:12701 marked, with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, But without Fittings and the base support ofr tank.l9.279.271000.0FalseNoneNoneFalseNoneFalse9270.00
3781874142858Nonecode29Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5030.525030.521.0FalseNoneNoneFalseNoneFalse5030.520
3781875142858Nonecode30Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach2637.832637.831.0FalseNoneNoneFalseNoneFalse2637.830
3781876142858Nonecode31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers completeEach1048.541048.541.0FalseNoneNoneFalseNoneFalse1048.540
3781877142858Nonecode32Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:m423.33423.3315.0FalseNoneNoneFalseNoneFalse6349.950
3781878142858Nonecode33Providing & Fixing brass bib cock of approved qualityEach314.15314.152.0FalseNoneNoneFalseNoneFalse628.30
3781879142858Nonecode34Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreEach341.96341.962.0FalseNoneNoneFalseNoneFalse683.920
3781880142858Nonecode35Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Each834.3834.32.0FalseNoneNoneFalseNoneFalse1668.60
3781881142858Nonecode36Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Each94.7694.762.0FalseNoneNoneFalseNoneFalse189.520
3781882142858Nonecode37Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyEach4104.554104.551.0FalseNoneNoneFalseNoneFalse4104.550
3781883142858Nonecode38Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thickm66.066.015.0FalseNoneNoneFalseNoneFalse990.00
3781884142858Nonecode39Short point upto 3m from tapping point to out let via switchPoint285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
3781885142858Nonecode40Medium point above 3m upto 6m from tapping point to out let via switchPoint394.0394.03.0FalseNoneNoneFalseNoneFalse1182.00
3781886142858Nonecode411.5 mm2m19.019.050.0FalseNoneNoneFalseNoneFalse950.00
3781887142858Nonecode422.5 mm2m26.026.030.0FalseNoneNoneFalseNoneFalse780.00
3781888142858Nonecode431-3 WayEach138.0138.02.0FalseNoneNoneFalseNoneFalse276.00
3781889142858Nonecode446 WayEach220.0220.02.0FalseNoneNoneFalseNoneFalse440.00
3781890142858Nonecode451 to 3 ModuleEach137.0137.02.0FalseNoneNoneFalseNoneFalse274.00
3781891142858Nonecode464 ModuleEach175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
3781892142858Nonecode476 ModuleEach234.0234.02.0FalseNoneNoneFalseNoneFalse468.00
3781893142858Nonecode486Amps One Way SwitchEach102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
3781894142858Nonecode496A Three Way socketEach166.0166.02.0FalseNoneNoneFalseNoneFalse332.00
3781895142858Nonecode50Stepped Fan Regulator Two ModuleEach276.0276.01.0FalseNoneNoneFalseNoneFalse276.00
3781896142858Nonecode516/16A Universal SocketEach236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3781897142858Nonecode5232A DP SwitchEach326.0326.01.0FalseNoneNoneFalseNoneFalse326.00
3781898142858Nonecode536A Bakelite Ceiling RoseNo78.078.05.0FalseNoneNoneFalseNoneFalse390.00
3781899142858Nonecode546A Lamp HolderNo71.071.05.0FalseNoneNoneFalseNoneFalse355.00
3781900142858Nonecode55Supplying & fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70. efficacy 80 lumen per W, life 25000 burning hours and Compliance condition. 12W, 6500KEach269.0269.08.0FalseNoneNoneFalseNoneFalse2152.00
3781901142858Nonecode56Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelEach2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
3781902142858Nonecode57Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, deliveringsuperior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, LED Streetlight 90 WNo5992.05992.01.0FalseNoneNoneFalseNoneFalse5992.00
3781903142858Nonecode58Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.PipeEach1045.01045.01.0FalseNoneNoneFalseNoneFalse1045.00
3781904142858Nonecode59Fixing all types and all capacities of fluorescent /false ceiling /spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / GirdersEach122.0122.05.0FalseNoneNoneFalseNoneFalse610.00
3781905142858Nonecode60Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each315.0315.01.0FalseNoneNoneFalseNoneFalse315.00
3781906142858Nonecode61Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.Each6086.06086.01.0FalseNoneNoneFalseNoneFalse6086.00
3781907142858Nonecode62Supplying and fixing of Shunt trip suitable for MCCB.CBCTEach1703.01703.01.0FalseNoneNoneFalseNoneFalse1703.00
3781908142858Nonecode636-32 Amps SPEach415.0415.05.0FalseNoneNoneFalseNoneFalse2075.00
3781909142858Nonecode646-32 Amps DPEach739.0739.05.0FalseNoneNoneFalseNoneFalse3695.00
3781910142858Nonecode656-32 Amps TPNEach1717.01717.01.0FalseNoneNoneFalseNoneFalse1717.00
3781911142858Nonecode66G I Grounding pipe, B-Class, 42 mm dia, 2.50 Mtr long, 3.2 mm thick with bolt, nut, GI strips and washers complete . Minimum weight of GI pipe : 7.3 Kg.No743.0743.01.0FalseNoneNoneFalseNoneFalse743.00
3781912142858Nonecode67Good quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each.No676.0676.01.0FalseNoneNoneFalseNoneFalse676.00
3781913142858Nonecode68Good quality Salt for grounding purposes packed in 50 Kg gunny bag.Bag310.0310.01.0FalseNoneNoneFalseNoneFalse310.00
3781914142858Nonecode69Digging pit for G I Pipe tye earthing in Hard soilPer Pit759.0759.01.0FalseNoneNoneFalseNoneFalse759.00
3781915142858Nonecode70Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 135 LPM @ 84 m = 12 STG Outlet Dia - 2.00" (Item-13.13.4 page-151 of Common SR Volume - V,2023-24)Each28837.028837.01.0FalseNoneNoneFalseNoneFalse28837.00
3781916142858Nonecode71Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 m2 (Item-13.22, Page-154 of Common SR Volume - V, 2023-24)m135.0135.0170.0FalseNoneNoneFalseNoneFalse22950.00
3781917142858Nonecode72Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps (Item-13.23.2, Page-155 of Common SR Volume - V, 2023-24)Each9550.09550.01.0FalseNoneNoneFalseNoneFalse9550.00
3781918142858Nonecode73Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (Item-13.25, Page-155 of Common SR Volume - V, 2023-24)Kvar550.0550.01.0FalseNoneNoneFalseNoneFalse550.00
3781919142858Nonecode74MCB:Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.(Item-13.26, Page-155 of Common SR Volume - V, 2023-24)Per 3 Poles1150.01150.01.0FalseNoneNoneFalseNoneFalse1150.00
3781920142858Nonecode75Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring, freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments (Item-13.28, Page-155 of Common SR Volume - V, 2023-24)m575.0575.0150.0FalseNoneNoneFalseNoneFalse86250.00
3781921142858Nonecode76Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (Item-32, Page-163 of Common SR Volume - V, 2021-22)Job6150.06150.01.0FalseNoneNoneFalseNoneFalse6150.00
3781922142858Nonecode77Labor charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipment's,m165.0165.010.0FalseNoneNoneFalseNoneFalse1650.00
3781923142858Nonecode78Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit (Item-13.37, Page-156 of Common SR Volume - V, 2023-24)m85.085.015.0FalseNoneNoneFalseNoneFalse1275.00
3781924142858Nonecode79Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth)Upto 50m depthm309.0309.050.0FalseNoneNoneFalseNoneFalse15450.00
3781925142858Nonecode80Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) above 50m and upto100m depthm387.0387.050.0FalseNoneNoneFalseNoneFalse19350.00
3781926142858Nonecode81Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) above 100m and upto 150m depthm412.0412.050.0FalseNoneNoneFalseNoneFalse20600.00
3781927142858Nonecode82Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (Item-12.32 Page-143 of Common SR Volume - V, 2023-24)m1933.01933.020.0FalseNoneNoneFalseNoneFalse38660.00
3781928142858Nonecode83Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ( Item-12.34 Page-143 of Common SR Volume - V, 2023-24)Each164.0164.01.0FalseNoneNoneFalseNoneFalse164.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17236415320000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17236415320000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17236415320000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17236415320000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17236415320000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneDepartment Registration DetailsNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing workNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker DetailsNoneNone
NoneNoneNoneNoneclass 2 pwd licenceOthersclass 2 pwd licence
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
GST and PAN CardTrueTechnical Bid
LOC 30 percent an amount as per KW1 Book lateTrueTechnical Bid
satisfactory completed as a prime contractor at least one similar work to an extent of 50percent of the cost of similar work of Quantity wise such as Excavation,PCC,RCC,Steel,plaster EtcTrueTechnical Bid
Incase Contractor participating in the tendor submit a lower rate. the difference amount shall be paid in advance as security deposit in any nationalized bankTrueTechnical Bid
Class-2 and above KPWD Registration CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone