3779006 | 142661 | None | CODE1 | PART-A:Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 123.2 | 123.2 | 90.0 | False | None | None | False | None | False | 11088.0 | 0 |
3779007 | 142661 | None | CODE2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 54.88 | 54.88 | 39.94 | False | None | None | False | None | False | 2191.9072 | 0 |
3779008 | 142661 | None | CODE3 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). | Cum | 5402.88 | 5402.88 | 2.75 | False | None | None | False | None | False | 14857.92 | 0 |
3779009 | 142661 | None | CODE4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 179.2 | 179.2 | 69.1 | False | None | None | False | None | False | 12382.72 | 0 |
3779010 | 142661 | None | CODE5 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 6441.96 | 6441.96 | 11.4 | False | None | None | False | None | False | 73438.344 | 0 |
3779011 | 142661 | None | CODE6 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Isolated Footing & Pillers etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 7039.2 | 7039.2 | 60.3 | False | None | None | False | None | False | 424463.76 | 0 |
3779012 | 142661 | None | CODE7 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Kg | 98.56 | 98.56 | 12844.79 | False | None | None | False | None | False | 1265982.5024 | 0 |
3779013 | 142661 | None | CODE8 | Providing and constructing Laterite size stone masonry including cost of conveyance of all material curing etc. complete as per specification IS 3620/197 having compressive strength not less than 3.5N/mm2 for saturated dry samples for super structure with cement mortar 1:6 (1 cement : 6 coarse sand ) | Cum | 6658.4 | 6658.4 | 28.38 | False | None | None | False | None | False | 188965.392 | 0 |
3779014 | 142661 | None | CODE9 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 68995.36 | 68995.36 | 1.59 | False | None | None | False | None | False | 109702.6224 | 0 |
3779015 | 142661 | None | CODE10 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 30mm, thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications (excluding cost of fixtures) etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Sqm | 4323.2 | 4323.2 | 6.93 | False | None | None | False | None | False | 29959.776 | 0 |
3779016 | 142661 | None | CODE11 | Providing and laying 12mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1cement : 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Sqm | 315.84 | 315.84 | 440.51 | False | None | None | False | None | False | 139130.6784 | 0 |
3779017 | 142661 | None | CODE12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1150.24 | 1150.24 | 1.43 | False | None | None | False | None | False | 1644.8432 | 0 |
3779018 | 142661 | None | CODE13 | Providing and laying vitrified floor tiles in different sizes (thickness to be specifie by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1229.76 | 1229.76 | 124.8 | False | None | None | False | None | False | 153474.048 | 0 |
3779019 | 142661 | None | CODE14 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 44.8 | 44.8 | 462.28 | False | None | None | False | None | False | 20710.144 | 0 |
3779020 | 142661 | None | CODE15 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 132.16 | 132.16 | 440.51 | False | None | None | False | None | False | 58217.8016 | 0 |
3779021 | 142661 | None | CODE16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.6 | 145.6 | 99.06 | False | None | None | False | None | False | 14423.136 | 0 |
3779022 | 142661 | None | CODE17 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Sqm | 1090.88 | 1090.88 | 8.77 | False | None | None | False | None | False | 9567.0176 | 0 |
3779023 | 142661 | None | CODE18 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includ ing pointing the joints with white cement and matching pigment etc., complete | Sqm | 689.92 | 689.92 | 2.7 | False | None | None | False | None | False | 1862.784 | 0 |
3779024 | 142661 | None | CODE19 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal bead ing with screws, shall be supplied by department free of cost: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, la bour, usage charges of machinery complete as per specifications and
as per directions of the Engineer-in-Charge | Kg | 39.2 | 39.2 | 267.44 | False | None | None | False | None | False | 10483.648 | 0 |
3779025 | 142661 | None | CODE20 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications | Kg | 509.6 | 509.6 | 34.38 | False | None | None | False | None | False | 17520.048 | 0 |
3779026 | 142661 | None | CODE21 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. | Sqm | 1025.92 | 1025.92 | 12.6 | False | None | None | False | None | False | 12926.592 | 0 |
3779027 | 142661 | None | CODE22 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge | Sqm | 532.0 | 532.0 | 2.1 | False | None | None | False | None | False | 1117.2 | 0 |
3779028 | 142661 | None | CODE23 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification -do- 30 mm thick both side commercial | Sqm | 2954.56 | 2954.56 | 2.1 | False | None | None | False | None | False | 6204.576 | 0 |
3779029 | 142661 | None | CODE24 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | No | 4030.88 | 4030.88 | 1.0 | False | None | None | False | None | False | 4030.88 | 0 |
3779030 | 142661 | None | CODE25 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | No | 4509.12 | 4509.12 | 1.0 | False | None | None | False | None | False | 4509.12 | 0 |
3779031 | 142661 | None | CODE26 | Earth work excavation for Foundation by manual means for all Buildings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.
In all kinds of soils Depth upto 1.5 m | Cum | 208.32 | 208.32 | 17.33 | False | None | None | False | None | False | 3610.1856 | 0 |
3779032 | 142661 | None | CODE27 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 6442.24 | 6442.24 | 2.16 | False | None | None | False | None | False | 13915.2384 | 0 |
3779033 | 142661 | None | CODE28 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Columns etc complete with all lead & lift as per the direction of the Engineer-in-Charge of the work. | Cum | 7271.04 | 7271.04 | 25.62 | False | None | None | False | None | False | 186284.0448 | 0 |
3779034 | 142661 | None | CODE29 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. 11.16.2 | Kg | 152.32 | 152.32 | 2191.32 | False | None | None | False | None | False | 333781.8624 | 0 |
3779035 | 142661 | None | CODE30 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 622.72 | 622.72 | 436.0 | False | None | None | False | None | False | 271505.92 | 0 |
3779036 | 142661 | None | CODE31 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) | Sqm | 404.32 | 404.32 | 16.0 | False | None | None | False | None | False | 6469.12 | 0 |
3779037 | 142661 | None | CODE32 | Providing and installing of approved make pre painted Galvolume iron accessories, like, plain, ridges, plain gutter, plain flashing, corner Trim, etc. The total coated thickness (TCT) of the sheet shall be 0.47 mm +/- 0.02 tolerance mm Zinc-Alu Alloy coating AZ 150 gsm as per ASTM 1397/755 -550 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 20-22 microns using self drilling / self tapping screws of 25 mm length. (width upto 500-600 mm only), to be fixed over the existing purlins, rafters, channels and trusses. | m | 310.2 | 310.2 | 104.92 | False | None | None | False | None | False | 32546.184 | 0 |
3779038 | 142661 | None | CODE33 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary
32 mm dia 2.5 mm thick | m | 93.0 | 93.0 | 150.0 | False | None | None | False | None | False | 13950.0 | 0 |
3779039 | 142661 | None | CODE34 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010
3C x 2.5 mm2 | m | 109.0 | 109.0 | 300.0 | False | None | None | False | None | False | 32700.0 | 0 |
3779040 | 142661 | None | CODE35 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2 | m | 40.0 | 40.0 | 300.0 | False | None | None | False | None | False | 12000.0 | 0 |
3779041 | 142661 | None | CODE36 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.
6A SP Switch | No | 43.0 | 43.0 | 31.0 | False | None | None | False | None | False | 1333.0 | 0 |
3779042 | 142661 | None | CODE37 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fitting 1 x 4' - 36/40 W | No | 1197.0 | 1197.0 | 12.0 | False | None | None | False | None | False | 14364.0 | 0 |
3779043 | 142661 | None | CODE38 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition
LED square or round down light 15-18W | No | 1249.0 | 1249.0 | 5.0 | False | None | None | False | None | False | 6245.0 | 0 |
3779044 | 142661 | None | CODE39 | Supplying & fixing retrofit type-PL- LED Lamp ...... W LED linear source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18-20 W | No | 691.0 | 691.0 | 5.0 | False | None | None | False | None | False | 3455.0 | 0 |
3779045 | 142661 | None | CODE40 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.
48" Sweep (1200 mm) Regular model | No | 2085.0 | 2085.0 | 12.0 | False | None | None | False | None | False | 25020.0 | 0 |
3779046 | 142661 | None | CODE41 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.
6A Three Way 5 Pin Socket | No | 65.0 | 65.0 | 2.0 | False | None | None | False | None | False | 130.0 | 0 |
3779047 | 142661 | None | CODE42 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200 x 90 x 65 mm, | No | 169.0 | 169.0 | 2.0 | False | None | None | False | None | False | 338.0 | 0 |
3779048 | 142661 | None | CODE43 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. | No | 335.0 | 335.0 | 2.0 | False | None | None | False | None | False | 670.0 | 0 |
3779049 | 142661 | None | CODE44 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.
12" x 12" x 3" (300 x 300 x 76 mm) | Sq CM | 0.26 | 0.26 | 1160.0 | False | None | None | False | None | False | 301.6 | 0 |
3779050 | 142661 | None | CODE45 | Supplying and fixing PVC/metal conduit Deep junction box
32 mm deep Junction box | No | 112.0 | 112.0 | 1.0 | False | None | None | False | None | False | 112.0 | 0 |
3779051 | 142661 | None | CODE46 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6 Way | No | 69.0 | 69.0 | 16.0 | False | None | None | False | None | False | 1104.0 | 0 |
3779052 | 142661 | None | CODE47 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned
LED Streetlight 40W | No | 250.0 | 250.0 | 1.0 | False | None | None | False | None | False | 250.0 | 0 |
3779053 | 142661 | None | CODE48 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | No | 3651.0 | 3651.0 | 1.0 | False | None | None | False | None | False | 3651.0 | 0 |
3779054 | 142661 | None | CODE49 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.
16 A | No | 4200.0 | 4200.0 | 4.0 | False | None | None | False | None | False | 16800.0 | 0 |
3779055 | 142661 | None | CODE50 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers | No | 125.0 | 125.0 | 11.0 | False | None | None | False | None | False | 1375.0 | 0 |
3779056 | 142661 | None | CODE51 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.
16 - 32 A SP | No | 190.0 | 190.0 | 5.0 | False | None | None | False | None | False | 950.0 | 0 |
3779057 | 142661 | None | CODE52 | 1.1 kv XLPE or Heat resistant PVC insulated, PVC extruded inner Sheath armoured UG cable as per IS 1554 (Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistivity as per IS-3975-25 Sq mm , 4 core (13 GI strips - 4x0.8mm) | Km | 245629.26 | 245629.26 | 0.16 | False | None | None | False | None | False | 39300.6816 | 0 |
3779058 | 142661 | None | CODE53 | Earthwork excavation for cable trench of 0.5 to 0.75 Mtr width and depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, supplying and Displaying necessary danger boards at every 100 Mtr whereever necessary as directed Inordinary soil | Cum | 384.54 | 384.54 | 346.86 | False | None | None | False | None | False | 133381.5444 | 0 |
3779059 | 142661 | None | CODE54 | Laying of cable in existing trench/G.I pipe/ stone ware/ RCC Hume pipe using Wooden /Aluminium Rollera as directed by the departmental staff - LT cable - 2.5 to 25 sq mm | Km | 23899.16 | 23899.16 | 0.15 | False | None | None | False | None | False | 3584.874 | 0 |
3779060 | 142661 | None | CODE55 | Refilling the cable trenches with selected available earth from trench excavation incxluding watering , consolidation in layers of 15 cm. thickness including depositing of the surplus earth with a lead of 200 Mtr- In Ordinary Soil | Cum | 85.78 | 85.78 | 379.6 | False | None | None | False | None | False | 32562.088 | 0 |
3779061 | 142661 | None | CODE56 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.
upto 50 mm conduit in brick wall | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 |
3779062 | 142661 | None | CODE57 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.
8 Way SP & N | No | 1302.0 | 1302.0 | 1.0 | False | None | None | False | None | False | 1302.0 | 0 |
3779063 | 142661 | None | CODE58 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A Dp Switch | No | 375.0 | 375.0 | 1.0 | False | None | None | False | None | False | 375.0 | 0 |
3779064 | 142661 | None | CODE59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | No | 313.0 | 313.0 | 12.0 | False | None | None | False | None | False | 3756.0 | 0 |
3779065 | 142661 | None | CODE60 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 25mm dia, 10 kg/sqcm & class 5 | m | 71.68 | 71.68 | 35.0 | False | None | None | False | None | False | 2508.8 | 0 |
3779066 | 142661 | None | CODE61 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 32mm dia, 6kg/sqcm & class 3 | m | 52.64 | 52.64 | 40.0 | False | None | None | False | None | False | 2105.6 | 0 |
3779067 | 142661 | None | CODE62 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 63mm dia, 6 kg/sqcm & class 3 | m | 171.36 | 171.36 | 60.0 | False | None | None | False | None | False | 10281.6 | 0 |
3779068 | 142661 | None | CODE63 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 644.0 | 644.0 | 50.0 | False | None | None | False | None | False | 32200.0 | 0 |
3779069 | 142661 | None | CODE64 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 32 mm dia GM (Copper alloy) Gate valves | m | 1498.56 | 1498.56 | 2.0 | False | None | None | False | None | False | 2997.12 | 0 |
3779070 | 142661 | None | CODE65 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS markFor 25 mm dia GM (Copper alloy) Gate valves | No | 1309.28 | 1309.28 | 2.0 | False | None | None | False | None | False | 2618.56 | 0 |
3779071 | 142661 | None | CODE66 | Providing and Placing on terrace (at all floor levels) polythelene water storage tank IS 12701 marked with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fitting and the base support of tank. | l | 8.96 | 8.96 | 1000.0 | False | None | None | False | None | False | 8960.0 | 0 |
3779072 | 142661 | None | CODE67 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | No | 386.4 | 386.4 | 2.0 | False | None | None | False | None | False | 772.8 | 0 |
3779073 | 142661 | None | CODE68 | Removal of existing cement concrete wearing coat including its disposal complete as per Technical Specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead. | Sqm | 147.84 | 147.84 | 72.2 | False | None | None | False | None | False | 10674.048 | 0 |
3779074 | 142661 | None | CODE69 | Clearing and grubbing land including uprooting rank vegetable grass, bushes, shrubs, saplings and trees upto 300mm girth by manual means, in areas of light jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable materials from road boundary etc. including cost of labour charges, all lead and lifts, etc. complete as directed by the Engineer in charge. | Sqm | 15.68 | 15.68 | 1632.72 | False | None | None | False | None | False | 25601.0496 | 0 |
3779075 | 142661 | None | CODE70 | SITE CLEARANCE: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. ii)By Mechanical Means using Dozer, A)In area of light jungle. | Sqm | 128688.0 | 128688.0 | 0.01 | False | None | None | False | None | False | 1286.88 | 0 |
3779076 | 142661 | None | CODE71 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage& other appurtenances required to complete the work.In Ordinary rock and Soft rock upto 300 mm depth. Earthwork excavation for plantation-koti chennayya theme park, Earthwork excavation for mexican grass | Cum | 506.24 | 506.24 | 31.68 | False | None | None | False | None | False | 16037.6832 | 0 |
3779077 | 142661 | None | CODE72 | Earth work excavation for Foundation by manual means for all Buildings, Bridges, Retaining walls,Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m | Cum | 222.88 | 222.88 | 180.0 | False | None | None | False | None | False | 40118.4 | 0 |
3779078 | 142661 | None | CODE73 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work | Cum | 450.24 | 450.24 | 10.83 | False | None | None | False | None | False | 4876.0992 | 0 |
3779079 | 142661 | None | CODE74 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates. | Cum | 6637.12 | 6637.12 | 14.84 | False | None | None | False | None | False | 98494.8608 | 0 |
3779080 | 142661 | None | CODE75 | Procurement of farmyard manure/compost, sand and red-earth (ingredients) required for raising seedlings inclusive of transportation, breaking of clods, sieving and heaping each ingredient separately at nursery site (Ceiling rate) Fine coarse Red-earth/soil | Cum | 603.9 | 603.9 | 8.21 | False | None | None | False | None | False | 4958.019 | 0 |
3779081 | 142661 | None | CODE76 | Procurement of farmyard manure/compost, sand and red-earth (ingredients) required for raising seedlings inclusive of transportation, breaking of clods, sieving and heaping each ingredient separately at nursery site (Ceiling rate) Natural Sand | Cum | 1307.6 | 1307.6 | 164.26 | False | None | None | False | None | False | 214786.376 | 0 |
3779082 | 142661 | None | CODE77 | Procurement of farmyard manure/compost, sand and red-earth (ingredients) required for raising seedlings inclusive of transportation, breaking of clods, sieving and heaping each ingredient separately at nursery site (Ceiling rate) Farm yard manure/compost | Cum | 1775.54 | 1775.54 | 0.99 | False | None | None | False | None | False | 1757.7846 | 0 |
3779083 | 142661 | None | CODE78 | Red Soil (Horticulture SR, Part X , 1.1 , Page no. 61) | Cum | 648.07 | 648.07 | 1.49 | False | None | None | False | None | False | 965.6243 | 0 |
3779084 | 142661 | None | CODE79 | Supplying and planting of Eugenia of 0.20 m height in a pit of 0.3 m (minimum width) with red soil (50%) mixed with 25% of sand and 25% of farmyard manure for a minimum depth of 0.30 m. The cost shall include the supplying and planting of plants in the soil as per the specifications, labour, maintenance for 2 years and using all necessary materials. The work shall be executed as per the instructions of Engineer | No | 300.0 | 300.0 | 25.0 | False | None | None | False | None | False | 7500.0 | 0 |
3779085 | 142661 | None | CODE80 | Supplying and planting of Ball arelia of 0.20 m height in a pit of 0.3 m (minimum width) with red soil (50%) mixed with 25% of sand and 25% of farmyard manure for a minimum depth of 0.30 m. The cost shall include the supplying and planting of plants in the soil as per the specifications, labour, maintenance for 2 years and using all necessary materials. The work shall be executed as per the instructions of Engineer | No | 300.0 | 300.0 | 20.0 | False | None | None | False | None | False | 6000.0 | 0 |
3779086 | 142661 | None | CODE81 | Supplying and planting of Bougainvillea of 0.30 m height in a pit of 0.3 m (minimum width) with red soil (50%) mixed with 25% of sand and 25% of farmyard manure for a minimum depth of 0.30 m. The cost shall include the supplying and planting of plants in the soil as per the specifications, labour, maintenance for 2 years and using all necessary materials. The work shall be executed as per the instructions of Engineer | No | 500.0 | 500.0 | 20.0 | False | None | None | False | None | False | 10000.0 | 0 |
3779087 | 142661 | None | CODE82 | Lawn development cost .Mexican grass ,vol 8,csr 2022-23,item no:I,C,page no:50 | Sqm | 655.2 | 655.2 | 72.2 | False | None | None | False | None | False | 47305.44 | 0 |
3779088 | 142661 | None | CODE83 | Granite Pergolas : Supplying and installation of Karkala Grey Granite Pergola finished with 3 line dressing as per design of overall size 3mX3.07m including foundation. The columns (4 Nos) shall be tapered with base diameter of 0.3m and top dia of 0.23m of height 2.7m + 0.6m foundation depth. Main beams (2 Nos) of 0.2X0.25m cross section wih chamfered ends shall be fixed to the top of columns horizontally. The jointing shall be mortise and tenon system using steel rods and adhesives if required. Rafter Beams with chamfered ends (7 Nos) of 0.15x0.23m shall be placed above the main beams using dado joint (slots). The pergola shall be covered with approved Galvalume Sheets as roofing and 100x100mm grid mesh above the roof. Installation/foundation shall be using PCC bed and cement concrete as indicated in the drawing.Thorough cleaning or sandblasting to be done before handover. This specification shall be read with attached drawing for all dimensions and designs. | Set | 217400.0 | 217400.0 | 1.0 | False | None | None | False | None | False | 217400.0 | 0 |
3779089 | 142661 | None | CODE84 | Supply and Fixing of Karkala Grey Granite coping of 40mm thick and 0.35m wide finished with 4 line dressing(on all exposed sides) over the existing masonry planter box.Thorough cleaning/sandblasting to be done before handover. | Rmtr | 2000.0 | 2000.0 | 162.0 | False | None | None | False | None | False | 324000.0 | 0 |
3779090 | 142661 | None | CODE85 | Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plas tered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification | Sqm | 2219.84 | 2219.84 | 16.33 | False | None | None | False | None | False | 36249.9872 | 0 |
3779091 | 142661 | None | CODE86 | Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 | Cum | 219.52 | 219.52 | 6.15 | False | None | None | False | None | False | 1350.048 | 0 |
3779092 | 142661 | None | CODE87 | Providing and fixing Karkala grey granite stone benches ,inluding cutting,Placing in position ,etc....whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. | No | 28000.0 | 28000.0 | 4.0 | False | None | None | False | None | False | 112000.0 | 0 |
3779093 | 142661 | None | CODE88 | Providing and fixing of Three line dressed Karkala gray granite stone cladding slabs on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & providing grass in between the cladding stones for 50mm width. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification and as per the guidance of engineer incharge | Sqm | 2800.0 | 2800.0 | 72.2 | False | None | None | False | None | False | 202160.0 | 0 |
3779094 | 142661 | None | CODE89 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink, Orissa Blue or equivalent. | Sqm | 3226.72 | 3226.72 | 43.68 | False | None | None | False | None | False | 140943.1296 | 0 |
3779095 | 142661 | None | CODE90 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge. | Sqm | 560.0 | 560.0 | 616.14 | False | None | None | False | None | False | 345038.4 | 0 |
3779096 | 142661 | None | CODE91 | Providing and fixing of hollow precast planterbowl of 750 mm height which is cast using M-30 grade concrete with Ordinary Portland Cement by using vibro-compaction technique for a compressive strength of concrete for 30MPa at 28 days. Reinforcements include fabrication of micro trusses using 4.7 mm Torkari TMT Bars and 3 mm MS Rods and they are welded to achieve the required shape. The thickness of the planterbowl shall vary from 100 to 150 mm as shown in the drawing. Provision for drain hole of 12mm inside diameter should be provided. The planterbowl shall be finished with cement grout of uniformly smooth texture without any bug holes and smooth mold seams and finished with exterior grade cement putty. It shall be painted using Acrylic based paint as per the instructions and fixed at site. The cost shall include bare cost of all materials, cost of reinforcements, transportation charges, fixing charges, labour etc., The work shall be carried out as per the detailed specifications , drawings | No | 45000.0 | 45000.0 | 2.0 | False | None | None | False | None | False | 90000.0 | 0 |
3779097 | 142661 | None | CODE92 | Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08.Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 8W 1 Mtr Height | No | 3651.0 | 3651.0 | 41.0 | False | None | None | False | None | False | 149691.0 | 0 |
3779098 | 142661 | None | CODE93 | WALKOVER LIGHTS- Supply and fixing of outdoor grade LED walkover light (flushed to floor) with die cast aluminium body 304 stainless steel housing Transparent tempered glass diffuser IP67 90V-260V AC, CCT value of 4500K and power wattage of 6W and shall have minimum warranty of 2 years from date of commissioning. The cost shall include supply, fixing, associated civil works, all necessary accessories Or Equivalent Product | Each | 8473.0 | 8473.0 | 46.0 | False | None | None | False | None | False | 389758.0 | 0 |
3779099 | 142661 | None | CODE94 | Supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130:1984 and virigin PVC Insulation sheathed suitable for working voltage upto 1100 volts as per IS 694:2010( 3CX4Sqmm) | Rmtr | 119.0 | 119.0 | 431.6 | False | None | None | False | None | False | 51360.4 | 0 |
3779100 | 142661 | None | CODE95 | Supplying heavy guage PVC Conduit pipe….dia….mm thick conforming to IS2509 with suitable size bends,junction boxes,adhesive paste etc,and fixing using inverted wood plugs incase of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick walls nd cement plastering.The damaged portion using heavy guage saddles at an interval of 700mm using NF screws(32mm dia 2.5mm thick) | Rmtr | 100.0 | 100.0 | 215.8 | False | None | None | False | None | False | 21580.0 | 0 |
3779101 | 142661 | None | CODE96 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(16SWG)K | Sqm | 0.38 | 0.38 | 16000.0 | False | None | None | False | None | False | 6080.0 | 0 |
3779102 | 142661 | None | CODE97 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. | Sqm | 0.29 | 0.29 | 9000.0 | False | None | None | False | None | False | 2610.0 | 0 |
3779103 | 142661 | None | CODE98 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. | No | 1242.0 | 1242.0 | 1.0 | False | None | None | False | None | False | 1242.0 | 0 |
3779104 | 142661 | None | CODE99 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | No | 747.0 | 747.0 | 3.0 | False | None | None | False | None | False | 2241.0 | 0 |
3779105 | 142661 | None | CODE100 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(6-32 A SP) | No | 523.0 | 523.0 | 6.0 | False | None | None | False | None | False | 3138.0 | 0 |
3779106 | 142661 | None | CODE101 | Fixing halogen / metal hallid /svl/il/led flood light fitting over existing pole/wall ceiling including cla,bolts, nuts & wiring using suitable capacity wires | No | 189.0 | 189.0 | 46.0 | False | None | None | False | None | False | 8694.0 | 0 |
3779107 | 142661 | None | CODE102 | Supplying and Fixing of Glow Fixture Elephant CCT: 6000K, Material: High light transmittance FRP, Input VoltageDC24V Dimensions:1300mm x 750mm x 1100mm, IP65, Weather proof, with premium quality product of glow item. Weight- 20 to 30 kg, Fixing arrangement for light available. Item inclusive of driver to run. | No | 190550.84 | 190550.84 | 1.0 | False | None | None | False | None | False | 190550.84 | 0 |
3779108 | 142661 | None | CODE103 | Supply and Fixing of High quality 3 mtr self illuminated Pole, with 60W LED light Double side illuminated 20W/30W, Impact resistant extruded aluminium housing powder coated, with foundation plate and bolt, Material: Extruded aluminium, Body Colour Grey, Dimension - 120mm x 80mm x 3000mm, Protection Rating : IP65, Input power : AC 110 - 230V, 50Hz. | No | 51261.86 | 51261.86 | 24.0 | False | None | None | False | None | False | 1230284.64 | 0 |
3779109 | 142661 | None | CODE104 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975-4 core 16Sqmm | Rmtr | 143.56 | 143.56 | 500.0 | False | None | None | False | None | False | 71780.0 | 0 |
3779110 | 142661 | None | CODE105 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. - In existing trench/duct.- 6 sqmm to 16 sqmm | Rmtr | 11.37 | 11.37 | 500.0 | False | None | None | False | None | False | 5685.0 | 0 |
3779111 | 142661 | None | CODE106 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6978.72 | 6978.72 | 39.3 | False | None | None | False | None | False | 274263.696 | 0 |
3779112 | 142661 | None | CODE107 | Removing centering charges for Wall (5% on Finished rate of Concrete per cum---- Including cost of all materials, Labour, HOM, Loading & Unloading, curing with all leads and lifts etc, complete as per specifications & as directed by Engineer-in-charge of the work | Cum | 348.93 | 348.93 | 29.4 | False | None | None | False | None | False | 10258.542 | 0 |