createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723121701235
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd405000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose09-09-2024 16:28:29
tenderQueryClose21-08-2024 17:29:36
technicalBidOpen10-09-2024 16:29:13
publishedDate08-08-2024 19:04:53
publishedByPostDMA_EE3_CC_MYS
publishedByUserKPE11883 - D ASHWIN
bidValidityPeriod180
noOfCalls1
preBidMeetingDate19-08-2024 11:30:08
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08212418849
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1723121701285
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/WS/WORK_INDENT25549
titleConstruction of sump cum pump house in dum and deaf premises, laying of 355.6 mm MS Feeder line in A Ramanna circle to Umar kayam road, Tilak Nagar, mysuru.
descriptionConstruction of sump cum pump house in dum and deaf premises, laying of 355.6 mm MS Feeder line in A Ramanna circle to Umar kayam road, Tilak Nagar, mysuru.
categoryWORKS
categoryTextWorks
ecv22764758.98
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2163
locationNameDMA City Corporation Mysuru
provisionalAmount27000000.0
groupOverheadTotalNone
fileNumberMCC/WSUGD/WEST-1/DEMANDDEAF/MSLINE/15F/2024-25/01
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17231217010000NoneNoneWater supply/sewage linesConstruction of sump cum pump house in dum and deaf premises, laying of 355.6 mm MS Feeder line in A Ramanna circle to Umar kayam road, Tilak Nagar, mysuru.22764758.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3729158138522Nonecode01Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately. -do- Bituminous courseCum1309.351309.3574.4FalseNoneNoneFalseNoneFalse97415.640
3729159138522Nonecode02Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately. -do- Macadam RoadCum919.8919.8192.3FalseNoneNoneFalseNoneFalse176877.540
3729160138522Nonecode03Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separatelyCum591.15591.1537.5FalseNoneNoneFalseNoneFalse22168.1250
3729161138522Nonecode04Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead. By Manual Means. Cement Concrete Grade M-15 & M-20.Cum979.65979.652.016FalseNoneNoneFalseNoneFalse1974.97440
3729162138522Nonecode05Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. -do- In all kinds of soils Depth upto 1.5 m.Cum254.1254.141.256FalseNoneNoneFalseNoneFalse10483.14960
3729163138522Nonecode06Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. -do- In all kinds of soils. Depth upto 1.50m.Cum508.2508.2651.6424FalseNoneNoneFalseNoneFalse331164.667680
3729164138522Nonecode07Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- In all kinds of soils. Depth upto 1.50 mCum275.1275.11030.58FalseNoneNoneFalseNoneFalse283512.5580
3729165138522Nonecode08Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- In all kinds of soils. Depth exceeding 1.5 m, but not exceeding 3 m.Cum347.55347.55352.142FalseNoneNoneFalseNoneFalse122386.95210
3729166138522Nonecode09Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m.Cum476.7476.7108.7006FalseNoneNoneFalseNoneFalse51817.576020
3729167138522Nonecode10Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- Ordinary/soft rock (without requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m.Cum584.85584.8512.0778FalseNoneNoneFalseNoneFalse7063.701330
3729168138522Nonecode11Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. -do- Depth exceeding 1.5m, but not exceeding 3 m.Cum271.95271.9513.5FalseNoneNoneFalseNoneFalse3671.3250
3729169138522Nonecode12Drum Delineator in Construction Zone:- Provision of metal drum/empty bitumen drum delineator, 300 mm in diameter, 800 mm high, filled with earth for stability, painted in circumferential strips of alternate black and white 100 mm wide fitted with reflectors 3 Nos of 7.5 cm dia, all as per IRC:SP 55:2001.Each800.1800.120.0FalseNoneNoneFalseNoneFalse16002.00
3729170138522Nonecode13Design, manufacturing, supply, errection, trail running, performance test and commissioning of centrifugal pump of approved make conforming to IS:12699 (1989) (Reaffirmed 2009) having specified pump output under specified operating head coupled to HT/LT ,WITH motor of adeuate HP rating operating at suitable KV with flexible coupling, self water lubricated thrust bearings, Strainer, Frame discharge Tee with flanged end for connecting delivery pipe with all other standard accessories and saftey device& all necessary works complete as per specification. -do- 2 Nos of 30 HPHP11025.011025.060.0FalseNoneNoneFalseNoneFalse661500.00
3729171138522Nonecode14Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -do- Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.212.3435FalseNoneNoneFalseNoneFalse73409.26320
3729172138522Nonecode15Supply and fixing of Cast steel ASTM A 216 Gr.WCB double flanged Dual plate check valve Conforming to API 594 with latest amendments Shaft material shall be SS420/431 and spring shall be spring steel superior grade quality as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking with appurtenances., complete with all lead and lift. The rates are inclusive of cost of Galvanised Bolts and Nuts: For class 150 etc. complete. -do- 250mmEach23144.123144.12.0FalseNoneNoneFalseNoneFalse46288.20
3729173138522Nonecode16Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with: -do- Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6Cum6515.256515.2531.974FalseNoneNoneFalseNoneFalse208318.60350
3729174138522Nonecode17Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing).Pipe of 355.6mm dia -7.1mm thickRmtr8174.258174.25515.0FalseNoneNoneFalseNoneFalse4209738.750
3729175138522Nonecode18Providing and constructing coursed rubble face stone masonry using approved stones in cement mortar 1 : 3 proportion by volume including cost of all materials, machinery, labour, ramps, cleaning, packing mortar and wedging stone chips into joints, curing and all other ancillary operations completeCum5851.655851.6553.46FalseNoneNoneFalseNoneFalse312829.2090
3729176138522Nonecode19Supplying and fixing angle iron frame work fabricated out of M.S. angle iron 75 x 75 x 6 mm and M.S. Flat.. with bolts, washers etc and painted with 2 coats of red oxide and then two coats of approved paint.Mtr582.75582.75468.4FalseNoneNoneFalseNoneFalse272960.10
3729177138522Nonecode20Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing) for. Pipe bends,branches, tail pieces, reducers etc. for upto 500mm dia pipesKgs178.5178.53139.365FalseNoneNoneFalseNoneFalse560376.65250
3729178138522Nonecode21Providing 50 mm deep cement mortar pointing to face stone masonry in CM 1 : 2 proportion by volume including cost of all materials, labour, raking-out and cleaning joints, pressing mortar into joints, finishing, curing and all other ancillary operations completeCum207.9207.9237.6FalseNoneNoneFalseNoneFalse49397.040
3729179138522Nonecode22Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -do- Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6925.926925.9213.1767FalseNoneNoneFalseNoneFalse91260.7700640
3729180138522Nonecode23Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -do- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4518.1167FalseNoneNoneFalseNoneFalse113925.9621150
3729181138522Nonecode24Providing, of DI flanged pipe conforming to IS 8329 : 2000 with latest amendments with Cement Mortar Lining (CML) with Portland Slag Cement as per IS 455:1989 and Metallic Zinc Coating as per annexure A of IS 8329 with finishing layer of Bituminous Coating as per Annexure C of IS 8329 and Flanges: Metallic zinc rich epoxy paint & Bituminous Coating, laying true to line and hoisting in position and aligning to correct plumb including cost of jointing material, conveying to work spot with all lead. -do- For PN 10 250mmMtr13645.813645.812.0FalseNoneNoneFalseNoneFalse163749.60
3729182138522Nonecode25Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. HDPE Grade PE100-PN8.0,250mm diaRmtr2311.052311.05480.0FalseNoneNoneFalseNoneFalse1109304.00
3729183138522Nonecode26Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -do- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8865.048865.0414.31FalseNoneNoneFalseNoneFalse126858.72240
3729184138522Nonecode27Supplying and fixing angle iron frame work fabricated out of M.S. angle iron 50 x 50 x 6 mm and M.S. Flat.. with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.Mtr414.75414.75531.2FalseNoneNoneFalseNoneFalse220315.20
3729185138522Nonecode28Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-do- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum7028.667028.6643.7492FalseNoneNoneFalseNoneFalse307498.2520720
3729186138522Nonecode29Manufacturing, supplying, laying in position, aligning, jointing, testing and commissioning of electric resistance welded / submerged arc welded mild steel ( Fe-410 grade ) delivery pipes of specified diameter and plate thickness with flanged ends wherever required and provided with 1 coat 40 micron thick zinc rich epoxy primer paint and 3 coats 100 micron thick each coat coal tar epoxy paint for inner surface and 1 coat of 40 micron thick zinc rich epoxy primer paint and 2 coats of 100 micron thick each coat coal tar epoxy paint for outer surface including cost of all materials, machinery, labour, cutting, bending, welding, finishing, painting,conveying to spot, lowering, aligning, jointing,arranging water for testing, hydraulic testing at fabrication site and after laying and jointing at specified test pressure and all other ancillary operations complete as per specifications and approved drawings.Rmtr150318.0150318.01.358FalseNoneNoneFalseNoneFalse204131.8440
3729187138522Nonecode30Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint LNPE 250.Each4516.04516.09.0FalseNoneNoneFalseNoneFalse40644.00
3729188138522Nonecode31Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structuresTonne82961.5582961.5515.135FalseNoneNoneFalseNoneFalse1255623.059250
3729189138522Nonecode32Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge.Sqm883.05883.05213.75FalseNoneNoneFalseNoneFalse188751.93750
3729190138522Nonecode33Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..-do- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7787.017787.0147.3432FalseNoneNoneFalseNoneFalse368661.9718320
3729191138522Nonecode34Providing and fixing of ductile iron double flanged swing check valves with slanted seat or with lever weight with straight disc, with metallic corrosion proof and wear resistant seat faces with nickel overlay micro - finished/ Integral seat with body and disc in Ductile Iron in GGG 40/50 shaft of stainless steel and bearings of zinc free bronze and surface protection with epoxy liquid of GSK quality etc complete For PN 10.0. -do- 200mm.Each58895.5558895.552.0FalseNoneNoneFalseNoneFalse117791.10
3729192138522Nonecode35Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Elbow 90 Deg. 250Each10090.010090.04.0FalseNoneNoneFalseNoneFalse40360.00
3729193138522Nonecode36Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN 8, 160mm dia. (P.No. 113, SI.No. 10.2.10 of Common SR for Water supply and UGD 2023-24)Rmtr731.85731.85120.0FalseNoneNoneFalseNoneFalse87822.00
3729194138522Nonecode37Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 m openable length ( total length 90 m), having 50 nos rounds per 6 m length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/mm2 with tape (0.52 mm thick) and weight 43.478 g/m (cost of M.S. angle, C.C. blocks shall be paid separately)Mtr331.8331.8144.0FalseNoneNoneFalseNoneFalse47779.20
3729195138522Nonecode38Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..-do- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum11036.0211036.0232.868FalseNoneNoneFalseNoneFalse362731.905360
3729196138522Nonecode39Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete. -do- For sluice Valve of PN - 10.0 and 200mm.Each30144.4530144.458.0FalseNoneNoneFalseNoneFalse241155.60
3729197138522Nonecode40Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint LNPE 200mmEach3279.03279.08.0FalseNoneNoneFalseNoneFalse26232.00
3729198138522Nonecode41Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum279.3279.397.1999FalseNoneNoneFalseNoneFalse27147.932070
3729199138522Nonecode42Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint LNPE 160mmEach2068.02068.02.0FalseNoneNoneFalseNoneFalse4136.00
3729200138522Nonecode43Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs142.8142.8720.0FalseNoneNoneFalseNoneFalse102816.00
3729201138522Nonecode44Providing, fabricating, supplying and fixing at site various diameter MS MJ ends to suit CI / DI pipe as per the sketch . The cost is inclusive of all materials, i.e, rubber ‘O’ rings, flanges, bo lts and nuts, consumables, hire charges, tools and tackles, welding equipments, lead and lifts, etc. complete as per the instructions of Engineer in charge.For CI / DI pipes of 300mm diaEach5104.055104.052.0FalseNoneNoneFalseNoneFalse10208.10
3729202138522Nonecode45Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineer-in-chargeEach325.5325.5101.736FalseNoneNoneFalseNoneFalse33115.0680
3729203138522Nonecode46Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiingEach3774.753774.756.0FalseNoneNoneFalseNoneFalse22648.50
3729204138522Nonecode47Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Coupler 250mmEach4325.04325.010.0FalseNoneNoneFalseNoneFalse43250.00
3729205138522Nonecode48Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-chargeSqm38.8538.85504.0FalseNoneNoneFalseNoneFalse19580.40
3729206138522Nonecode49Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 300mm dia and 20mm thickEach4389.04389.03.0FalseNoneNoneFalseNoneFalse13167.00
3729207138522Nonecode50Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewe, effluent and water treatment plants, over head tanks, etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 ie. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats @ 0.70 kg per sqm per coatSqm454.65454.65210.25FalseNoneNoneFalseNoneFalse95590.16250
3729208138522Nonecode51Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 200mm dia and 20mm thick.Each2822.42822.410.0FalseNoneNoneFalseNoneFalse28224.00
3729209138522Nonecode52Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Coupler 160mmEach1366.01366.02.0FalseNoneNoneFalseNoneFalse2732.00
3729210138522Nonecode53Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workSqm8376.98376.99.18FalseNoneNoneFalseNoneFalse76899.9420
3729211138522Nonecode54Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for: Flanges of 400mm dia and 25mm thickEach6941.556941.5516.0FalseNoneNoneFalseNoneFalse111064.80
3729212138522Nonecode55Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm371.7371.7812.734FalseNoneNoneFalseNoneFalse302093.22780
3729213138522Nonecode56Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 100mm dia and 10mm thickEach725.55725.552.0FalseNoneNoneFalseNoneFalse1451.10
3729214138522Nonecode57Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Coupler 200mmEach2202.02202.010.0FalseNoneNoneFalseNoneFalse22020.00
3729215138522Nonecode58Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm450.45450.45504.0FalseNoneNoneFalseNoneFalse227026.80
3729216138522Nonecode59Making main bore in CI/DI/MS pipes with approved tools and procedures etc. for:50mmEach369.6369.62.0FalseNoneNoneFalseNoneFalse739.20
3729217138522Nonecode60Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm2764.652764.655.25FalseNoneNoneFalseNoneFalse14514.41250
3729218138522Nonecode61Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 150mm dia and 16mm thick.Each1688.41688.42.0FalseNoneNoneFalseNoneFalse3376.80
3729219138522Nonecode62Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 150mm dia and 12mm thickEach1284.151284.152.0FalseNoneNoneFalseNoneFalse2568.30
3729220138522Nonecode63Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum454.65454.65246.24FalseNoneNoneFalseNoneFalse111953.0160
3729221138522Nonecode64Supply and fixing of Single / Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/50. All internal parts such as float, shell with appurtenances., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation. For PN 10.0. For TP Air Valves of 50mm dia.Each29600.5529600.552.0FalseNoneNoneFalseNoneFalse59201.10
3729222138522Nonecode65Top cover of Rolling shutters 1.20 mm thick.Sqm588.0588.02.7FalseNoneNoneFalseNoneFalse1587.60
3729223138522Nonecode66Supply and delivery at site brand new best make pressure guage suitable for centrifugal pump confirming to latest IS standards. pressure guage 100mm.Each686.7686.73.0FalseNoneNoneFalseNoneFalse2060.10
3729224138522Nonecode67Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 250mm dia and 16mm thickEach3123.753123.7510.0FalseNoneNoneFalseNoneFalse31237.50
3729225138522Nonecode68Providing and Filling in foundation with granite / trap broken metal 100mm and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specificationsCum2816.12816.113.536FalseNoneNoneFalseNoneFalse38118.72960
3729226138522Nonecode69Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O“ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For Suilce Valve of PN - 10.0 and 50mmEach5811.755811.752.0FalseNoneNoneFalseNoneFalse11623.50
3729227138522Nonecode70Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- ChargeEach3240.33240.31.0FalseNoneNoneFalseNoneFalse3240.30
3729228138522Nonecode71Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500Kg WL (Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158:1991Each18587.118587.11.0FalseNoneNoneFalseNoneFalse18587.10
3729229138522Nonecode72Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 200mm dia and 16mm thickEach2363.552363.5511.0FalseNoneNoneFalseNoneFalse25999.050
3729230138522Nonecode73Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O“ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For Suilce Valve of PN - 10.0 and 350mmEach97894.6597894.653.0FalseNoneNoneFalseNoneFalse293683.950
3729231138522Nonecode74Providing and fixing Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs111.3111.3544.57FalseNoneNoneFalseNoneFalse60610.6410
3729232138522Nonecode75Digging of Pit 2.5 mtr depth for errection of 11mtr long tubular spun pole as per approved Drawing. Hard SoilCum4070.854070.851.0FalseNoneNoneFalseNoneFalse4070.850
3729233138522Nonecode76Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. 250mm Dia.Each48815.5548815.554.0FalseNoneNoneFalseNoneFalse195262.20
3729234138522Nonecode77Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm93.4593.45496.0FalseNoneNoneFalseNoneFalse46351.20
3729235138522Nonecode78Cutting charges only for cutting CI/DI/MS pipes already laid in the ground with necessary approved tools for:350mm dia pipesEach240.45240.456.0FalseNoneNoneFalseNoneFalse1442.70
3729236138522Nonecode79Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm155.4155.4450.0FalseNoneNoneFalseNoneFalse69930.00
3729237138522Nonecode80Providing cement concrete to poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). Base concreting with CC 1:4: 8: Pole base 11mtr spun pole (1000x1000x150mmEach882.0882.01.0FalseNoneNoneFalseNoneFalse882.00
3729238138522Nonecode81Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. 150mm Dia.Each18364.518364.52.0FalseNoneNoneFalseNoneFalse36729.00
3729239138522Nonecode82Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm145.95145.95283.5FalseNoneNoneFalseNoneFalse41376.8250
3729240138522Nonecode83Excavating of ramming/jacking/driving pit and receiving pit of size 5.00m(length) x 3.00m (breadth), up to 6.00 m depth in all soil strata including shoring and strutting including cutting of Asphalt/CC/Macadam road surface and removing the excavated stuff with all lead and lifts. The work includes formation of CC/RCC of 1:3:6 with or without 20mm steel with suitable spacing. The work also to receive the impacts driving pushing operation of encasing pipe. The cost includes driving the horizontal bore by pushing/jacking methods (trenchless technologyEach182236.95182236.952.0FalseNoneNoneFalseNoneFalse364473.90
3729241138522Nonecode84Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1622.251622.2528.278FalseNoneNoneFalseNoneFalse45873.98550
3729242138522Nonecode85Providing cement concrete to poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). Pole concreting with CC 1:2:4 (without coping): 11 mtrs Spun pole (1000x1000x2500mm)Each14704.214704.21.0FalseNoneNoneFalseNoneFalse14704.20
3729243138522Nonecode86Installation of product pipe by manual jacking method - Manufacturing, providing, transporting, rolling, lowering, laying & jointing, testing, commissioning of ERW (Electric Resistance Welded), SAW (Submerged Arc Welded) MS pipe (Fe-410 grade) conforming to IS 3589-2001 with latest ammendments including perfect linking welding of joints to correct position including cost and conveyance of pipes and materials with all lead ,lift, cost of labour, loading and unloading of pipes for the following diameters with specified thickness of plate as noted below including bailing out of water wherever necessary for laying of carrier pipe of suitable dia including inside and outside of casing pipe painted with two coats of Anti corrossive tankmastic paint. Installation of steel pipe by Ramming / Jacking method to cross Railway track / NH /BDA /BBMP/ Other roads/Existing utilities / NALA crossings, filling the gap between casing pipe and carrier pipe with quarry grit using compressor with all necessary equipments, plants etc, complete. Suitable spacers of HDP/ MS or other similar material should be provided in between carrier & casing pipe to prevent carrier pipe forming metallic contact with casing pipe. Note : a. The cost of jacking is inclusive of cost M.S. casing pipe of specified thickness b. The cost of carrying pipe is separate and provision shall be made as per site requirement c. The cost of Jacking includes all leads lifts, cost of consumables, fuel charges, labour. d. The cost of jacking and receving pits shall be proposed seperatelly as per site requirement. -do- Jacking of 600 mm dia & 10mm thick M.S. Casing PipEach31077.931077.970.0FalseNoneNoneFalseNoneFalse2175453.00
3729244138522Nonecode87Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., completeSqm1129.81129.888.635FalseNoneNoneFalseNoneFalse100139.8230
3729245138522Nonecode88Providing cement concerete to poles and Guy sets with material and labour including necessary curing etc., completeEach2331.02331.01.0FalseNoneNoneFalseNoneFalse2331.00
3729246138522Nonecode89Cutting charges only for cutting CI/DI/HDPE pipes already laid in the ground with necessary approved tools for:200mm dia pipes.Each122.85122.856.0FalseNoneNoneFalseNoneFalse737.10
3729247138522Nonecode90Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications.Cum168.0168.01491.375FalseNoneNoneFalseNoneFalse250551.00
3729248138522Nonecode91Providing and fixing 40mm dia. GI pipe medium duty pipes hand railing 3 rows fixed to RCC 1:2:4 vibrated post of 150x150mm at bottom and 100x150mm at top, placed at 2 Mtrs. intervals for a height of 750mm including curing, painting GI pipes with two coats of anticorrosive steel paint over a primer coat etc. with all lead lift etc.Sqm1393.351393.3539.5892FalseNoneNoneFalseNoneFalse55161.611820
3729249138522Nonecode92Erection of 11mtr long Concrete spun pole in a pit of 2.5 mtr depth.(Mechnised Labour).Each2671.22671.21.0FalseNoneNoneFalseNoneFalse2671.20
3729250138522Nonecode93Cutting charges only for cutting CI/DI/HDPE pipes already laid in the ground with necessary approved tools for:250mm dia pipes.Each175.35175.358.0FalseNoneNoneFalseNoneFalse1402.80
3729251138522Nonecode94Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specificationSqm1756.651756.65118.692FalseNoneNoneFalseNoneFalse208500.30180
3729252138522Nonecode95H - Frame Set for fixing 11kV, 200 Amps SB GOS/400 Amps DB GOS- (For DP structure for providing New GOS for sectionalisation) - GIEach6374.556374.552.0FalseNoneNoneFalseNoneFalse12749.10
3729253138522Nonecode96Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm182.7182.7365.583FalseNoneNoneFalseNoneFalse66792.01410
3729254138522Nonecode97Erection of H-Frame.Each339.15339.152.0FalseNoneNoneFalseNoneFalse678.30
3729255138522Nonecode98Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7521.0FalseNoneNoneFalseNoneFalse2535.750
3729256138522Nonecode9911kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018). GOS as per IS-9921, IS-1977Each9922.59922.52.0FalseNoneNoneFalseNoneFalse19845.00
3729257138522Nonecode100Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 O rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. 400mm Dia PN-16Each175320.6175320.62.0FalseNoneNoneFalseNoneFalse350641.20
3729258138522Nonecode101Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. -do- For DI/CI puddle flanges of 200mm diaEach3369.453369.452.0FalseNoneNoneFalseNoneFalse6738.90
3729259138522Nonecode102Fixing of GOS including wiring (11kV SB 200A).Each1159.21159.22.0FalseNoneNoneFalseNoneFalse2318.40
3729260138522Nonecode103Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. -do- For DI/CI puddle flanges of 250mm diaEach4735.54735.51.0FalseNoneNoneFalseNoneFalse4735.50
3729261138522Nonecode104Lightning Aresters 11kV, 5kA, Metal OxideEach966.0966.09.0FalseNoneNoneFalseNoneFalse8694.00
3729262138522Nonecode105Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and Providing and laying of MDPE pipe (PE80)-PN 12.5 manufactured in accordance with ISO 4427-1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm/ GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. "A" class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making "U" shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on the distribution main pipe with SS / Brass ferrule of size 1/2" x 3/4" and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS). The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles, PE 100 black colour pipe of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter cum flow regulator, water tight cap with O'ring, long spigot for making bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for drinking water service in WRC - NSF, UK and DVGW certificate, Germany. The Saddle should be manufactured Virgin Compounded PE 100 material. Tapping Tee or Saddles with coupler and compression fittings with cost of GI pipes, as per diagram, all specials such as GI tee, GI elbow, GI coupler, stopper with appurtenances, and brass or SS tap The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed off to a distance with an initial lead of 10 Kms. etc. complete for the following diameters: (for minimum length of 2m) etc. completeEach6874.356874.3597.0FalseNoneNoneFalseNoneFalse666811.950
3729263138522Nonecode106Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. -do- For DI/CI puddle flanges of 300mm dia.Each5965.055965.052.0FalseNoneNoneFalseNoneFalse11930.10
3729264138522Nonecode107Fixing of 3 Nos lightning arrestors including wiringEach124.95124.953.0FalseNoneNoneFalseNoneFalse374.850
3729265138522Nonecode108Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:MS angle of 65 x 65 x 10mmEach5041.055041.0510.0FalseNoneNoneFalseNoneFalse50410.50
3729266138522Nonecode10911kV, 5KN Composite/Polymeric Pin Insulator (20 m dia FRP Rod)Each215.25215.259.0FalseNoneNoneFalseNoneFalse1937.250
3729267138522Nonecode110Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm4.24.24000.0FalseNoneNoneFalseNoneFalse16800.00
3729268138522Nonecode11111kV Class, HG Fuse Unit with Solid Core Insulators (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) as per IS-5350 Part-2. Set/3 NNo1122.451122.453.0FalseNoneNoneFalseNoneFalse3367.350
3729269138522Nonecode112Fixing Horn Gap Fuses including fixing of cross arms and wiringNo248.85248.853.0FalseNoneNoneFalseNoneFalse746.550
3729270138522Nonecode113ACSR conductor as per IS-398 (Part - 2/1996) Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt : 214 kgs/kmNo48.5448.5422.5FalseNoneNoneFalseNoneFalse1092.150
3729271138522Nonecode114RCC Pole - 9.5 Mtr Long, 350 Kg WL for 33kV Lineas per REC StandardNo7884.457884.453.0FalseNoneNoneFalseNoneFalse23653.350
3729272138522Nonecode115Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved DrawingNo1188.61188.63.0FalseNoneNoneFalseNoneFalse3565.80
3729273138522Nonecode116Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth.No1168.651168.653.0FalseNoneNoneFalseNoneFalse3505.950
3729274138522Nonecode117Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). A) Base Concreting with CC 1:4: 8. a) Pole base for 11/9.5/9/8 Mtr supports (500x650x150mm)No286.65286.653.0FalseNoneNoneFalseNoneFalse859.950
3729275138522Nonecode118Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). B) Pole Concreting with CC 1:2:4 (without coping). a) 9 Mtr support (650x500x1700mm).Each3315.93315.93.0FalseNoneNoneFalseNoneFalse9947.70
3729276138522Nonecode119Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). C) Providing Coping for Pole with CC 1:2:4 (As per actuals). a) 150 mm all around the Pole for an height of 300 mm for RCC, PSCC PoleEach569.1569.13.0FalseNoneNoneFalseNoneFalse1707.30
3729277138522Nonecode120DP Set (2 Pole Strucrure Kit) as per IS-1977. For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - GI.Each9306.159306.151.0FalseNoneNoneFalseNoneFalse9306.150
3729278138522Nonecode121Erection of 2 Pole Structure using RCC/PSCC Pole 9 to 10 Mtr long.Each4340.74340.71.0FalseNoneNoneFalseNoneFalse4340.70
3729279138522Nonecode122DISC Insulator 45 kN Porcelain.Each535.5535.56.0FalseNoneNoneFalseNoneFalse3213.00
3729280138522Nonecode12311 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Each255645.6255645.61.0FalseNoneNoneFalseNoneFalse255645.60
3729281138522Nonecode124Load Break Switch with Panel.Each76900.9576900.951.0FalseNoneNoneFalseNoneFalse76900.950
3729282138522Nonecode125One Breaker Panel with Copper Busbar 350 MVA, 630 Amps as per IEC-62271/IS-3427.Each740735.1740735.11.0FalseNoneNoneFalseNoneFalse740735.10
3729283138522Nonecode126Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment.Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completelyEach31879.0531879.053.0FalseNoneNoneFalseNoneFalse95637.150
3729284138522Nonecode127Erection of HT metering Cubicle on PlatformEach1936.21936.21.0FalseNoneNoneFalseNoneFalse1936.20
3729285138522Nonecode128Supply of Transformer with copper windings & oil, cable termination type on both HT & LT outdoor type. do 250 kVA, 11 kV/433 V, 3 phase Dyn11.Each444626.7444626.71.0FalseNoneNoneFalseNoneFalse444626.70
3729286138522Nonecode129Erection of Transformer. do 100 kVA, 11 kV/433 V, 3 phase Dyn11Each19521.619521.61.0FalseNoneNoneFalseNoneFalse19521.60
3729287138522Nonecode130Erection of Transformer. do 250 kVA, 11 kV/433 V, 3 phase Dyn11.Each21925.0521925.051.0FalseNoneNoneFalseNoneFalse21925.050
3729288138522Nonecode13111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. Do 95 Sqmm, (54 GI Wires - 2.5 mm Dia).Km934149.3934149.30.44FalseNoneNoneFalseNoneFalse411025.6920
3729289138522Nonecode132Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. -do- HT Cable 3x95 to 150 SqmmKm64388.164388.10.44FalseNoneNoneFalseNoneFalse28330.7640
3729290138522Nonecode133GI Pipe - 150 mm DiaNo1360.81360.824.0FalseNoneNoneFalseNoneFalse32659.20
3729291138522Nonecode134Laying the GI Pipe 80mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.No97.6597.6512.0FalseNoneNoneFalseNoneFalse1171.80
3729292138522Nonecode135RCC Hume Pipes 2000mm long 150mm dia.No322.35322.3530.0FalseNoneNoneFalseNoneFalse9670.50
3729293138522Nonecode136Collars for RCC Hume Pipe 150 mm DiaNo86.186.130.0FalseNoneNoneFalseNoneFalse2583.00
3729294138522Nonecode137Laying and Jointing the pipes (100-150 mm), dia including lowering in Position: Fixing Collars etc., Joining with mud mortor complete. do RCNo72.4572.4560.0FalseNoneNoneFalseNoneFalse4347.00
3729295138522Nonecode138Burnt Brick (Class 35 Modular)No8.48.4500.0FalseNoneNoneFalseNoneFalse4200.00
3729296138522Nonecode139Cable Covering Tiles 125x250x40 mmNo10.7610.76600.0FalseNoneNoneFalseNoneFalse6456.00
3729297138522Nonecode140Covering cable with Tiles.Km4585.354585.350.2FalseNoneNoneFalseNoneFalse917.070
3729298138522Nonecode141Artificial Sand/Manufacture Sand.Cum1562.41562.40.011FalseNoneNoneFalseNoneFalse17.18640
3729299138522Nonecode142Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm.Km15550.515550.50.22FalseNoneNoneFalseNoneFalse3421.110
3729300138522Nonecode143Caution/Danger Board.No157.5157.510.0FalseNoneNoneFalseNoneFalse1575.00
3729301138522Nonecode144Fixing Danger BoardNo84.084.010.0FalseNoneNoneFalseNoneFalse840.00
3729302138522Nonecode145Spun Pole Painting (supplying and applying two coats of enamel paints to 11Mtrs spun pole) and painting all the metal parts of the structure with two coats of aluminium paint over primer.No10830.7510830.751.0FalseNoneNoneFalseNoneFalse10830.750
3729303138522Nonecode146Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable. do 3x95 SqmmSet4270.354270.3516.0FalseNoneNoneFalseNoneFalse68325.60
3729304138522Nonecode147Heat Shrinkable Type Transition Jointing Kit for XLPE Cable. do 3x95 SqmmSet10758.310758.32.0FalseNoneNoneFalseNoneFalse21516.60
3729305138522Nonecode148Making and Fixing pot head for HT Cable only. Heat shrinkable Type Terminations. do 3x95 to 3x150 Sqmm.Set2790.92790.916.0FalseNoneNoneFalseNoneFalse44654.40
3729306138522Nonecode149Making and Fixing pot head for HT Cable only. Heat shrinkable Straight Through Joint. do 3x95 to 3x150 SqmmSet2990.42990.42.0FalseNoneNoneFalseNoneFalse5980.80
3729307138522Nonecode150Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr.Cum60.960.9140.0FalseNoneNoneFalseNoneFalse8526.00
3729308138522Nonecode151Digging of Pit for providing GI Pipe type Earthing. do Hard Soil.Per Pit3139.53139.53.0FalseNoneNoneFalseNoneFalse9418.50
3729309138522Nonecode152Supply of Pipe type earthing Material. GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo780.15780.153.0FalseNoneNoneFalseNoneFalse2340.450
3729310138522Nonecode153Supply of Pipe type earthing Material. Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each.No709.8709.83.0FalseNoneNoneFalseNoneFalse2129.40
3729311138522Nonecode154Supply of Pipe type earthing Material. Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag325.5325.53.0FalseNoneNoneFalseNoneFalse976.50
3729312138522Nonecode155Providing GI Pipe Earthing (Excluding digging of pits).Per Pit199.5199.53.0FalseNoneNoneFalseNoneFalse598.50
3729313138522Nonecode156Route & Joint indicating slab with MS Anchor rodNo139.65139.6510.0FalseNoneNoneFalseNoneFalse1396.50
3729314138522Nonecode157Fixing of Route Joint Indicating SlabNo121.8121.810.0FalseNoneNoneFalseNoneFalse1218.00
3729315138522Nonecode158Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Shortcircuit with adjustable thermal magnetic release, Micro processor release shall have Earth Fault as perIS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. do FOUR Pole 250 A 25 kANo22460.5522460.551.0FalseNoneNoneFalseNoneFalse22460.550
3729316138522Nonecode159Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panelboard using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Shortcircuit with adjustable thermal magnetic release, Micro processor release shall have Earth Fault as perIS/IEC60947-2. (Icu 100 lcs). In 4P MCCB, all Poles should have protection for Short Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. -do- FOUR Pole 100 A 25 kANo8911.358911.353.0FalseNoneNoneFalseNoneFalse26734.050
3729317138522Nonecode160Supplying and fixing of Shunt trip suitable for MCCB.CBCT.No1788.151788.151.0FalseNoneNoneFalseNoneFalse1788.150
3729318138522Nonecode161Supplying fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross- 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. do 50-63 A TPNNo3242.43242.46.0FalseNoneNoneFalseNoneFalse19454.40
3729319138522Nonecode162Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439-3 and IK09 tested as per IS/IEC62262 with minimum IP43 protection provided with Polyurethane(PUR )gasket, with suitable earthing system, on wall/ woodboard/ flushmounting using required clA, bolts, nuts, etc. with provision for fixing of suitable type capacity MCCBs as an incomer for 3phase Double door with necessary bus bar completely wired to use on 440V 3phase 4wire powder coated paintingetc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. do 8 Way.No13235.2513235.251.0FalseNoneNoneFalseNoneFalse13235.250
3729320138522Nonecode163Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS2834. 3phase, 400/440V grade, for power factor improvement of rotating machineries like induction motor.Kvar504.0504.040.0FalseNoneNoneFalseNoneFalse20160.00
3729321138522Nonecode164Supplying, fixing and wiring Automatic PowerFactor controller circuit unit fully, static units controlled by 14stage micro processor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and voltage, to connect/disconnect banks, with automatic recognition or withstand ard programsEach22722.022722.02.0FalseNoneNoneFalseNoneFalse45444.00
3729322138522Nonecode165Supplying 250 A 4 x 30 x 10 mm Aluminium Strips rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., completel.Mtr3606.753606.7512.0FalseNoneNoneFalseNoneFalse43281.00
3729323138522Nonecode166Supplying and fixing angle iron frame work fabricated out of M.S.angle iron. and M.S.Flat. with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 100 x 50 x 6 mm C channelMtr793.8793.820.0FalseNoneNoneFalseNoneFalse15876.00
3729324138522Nonecode167Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSqm0.520.52200000.0FalseNoneNoneFalseNoneFalse104000.00
3729325138522Nonecode168Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor upto 20 HP capacitieEach949.22949.222.0FalseNoneNoneFalseNoneFalse1898.440
3729326138522Nonecode169COPPER CONTROL CABLE : 2C x 2.5 Sq mmMtr98.798.750.0FalseNoneNoneFalseNoneFalse4935.00
3729327138522Nonecode170COPPER CONTROL CABLE : 2C x 6 Sq mmMtr161.7161.750.0FalseNoneNoneFalseNoneFalse8085.00
3729328138522Nonecode171Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50HzAC with latest micro controller based, digital read out of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel boardEach9717.759717.752.0FalseNoneNoneFalseNoneFalse19435.50
3729329138522Nonecode172Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. do 32-40A 4 pole.Each5404.355404.351.0FalseNoneNoneFalseNoneFalse5404.350
3729330138522Nonecode173Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood boardEach474.6474.63.0FalseNoneNoneFalseNoneFalse1423.80
3729331138522Nonecode174Supplying, fixing and wiring 0 to 100A Direct Reading AC analog type Ammeter.Each550.2550.23.0FalseNoneNoneFalseNoneFalse1650.60
3729332138522Nonecode175Supplying, fixing and wiring rotary selectors with suitable for Ammeter.Each210.0210.03.0FalseNoneNoneFalseNoneFalse630.00
3729333138522Nonecode176Supplying, fixing and wiring rotary selectors witch suitable forVoltmeter.Each168.0168.03.0FalseNoneNoneFalseNoneFalse504.00
3729334138522Nonecode177Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape WoundEach590.1590.16.0FalseNoneNoneFalseNoneFalse3540.60
3729335138522Nonecode178Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each540.75540.7512.0FalseNoneNoneFalseNoneFalse6489.00
3729336138522Nonecode179Supplying of multi function digital meter with three line backlight CD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3phase ,4wire LT network with IP54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.Each9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3729337138522Nonecode180Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should been closed in chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layer so salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No4468.84468.815.0FalseNoneNoneFalseNoneFalse67032.00
3729338138522Nonecode181Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washersNo5085.155085.151.0FalseNoneNoneFalseNoneFalse5085.150
3729339138522Nonecode182Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. do 32No4294.54294.51.0FalseNoneNoneFalseNoneFalse4294.50
3729340138522Nonecode1831.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. do 50 Sqmm, 3.5 Core,Km187921.65187921.650.16FalseNoneNoneFalseNoneFalse30067.4640
3729341138522Nonecode1841.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. do 95 Sqmm, 3.5 CoreKm391875.75391875.750.06FalseNoneNoneFalseNoneFalse23512.5450
3729342138522Nonecode185Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. -do- LT Cable 35 to 95 SqmmKm32695.9532695.950.12FalseNoneNoneFalseNoneFalse3923.5140
3729343138522Nonecode186Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable. Up to 4C x 50 SqmmSet340.2340.212.0FalseNoneNoneFalseNoneFalse4082.40
3729344138522Nonecode187Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable. 3.5 x 70/95/120 SqmmSet401.1401.14.0FalseNoneNoneFalseNoneFalse1604.40
3729345138522Nonecode188Making and Fixing pot head for LT Cable only. Heat shrinkable Straight Through Joint. do 35 to 95 SqmmSet298.2298.24.0FalseNoneNoneFalseNoneFalse1192.80
3729346138522Nonecode189Making and Fixing pot head for LT Cable only. Heat shrinkable Type Terminations. do 35 to 95 SqmmSet199.5199.512.0FalseNoneNoneFalseNoneFalse2394.00
3729347138522Nonecode190Fixing foundation frame of channels and angle iron welding fixing in concrete aligning the RMU/PANEL on foundation bed, assembly of units, connecting Bus Bars from panel to panel initial filling of oil etc., complete. do 1 Panel.No5084.15084.13.0FalseNoneNoneFalseNoneFalse15252.30
3729348138522Nonecode191Fixing of GPRS Modems with AccessoriesEach1413.31413.31.0FalseNoneNoneFalseNoneFalse1413.30
3729349138522Nonecode192Laying of control cables from equipment to control panelsMtr15.7515.75100.0FalseNoneNoneFalseNoneFalse1575.00
3729350138522Nonecode193Supplying & Laying cable trays including welding, fixing of supports.Mtr791.7791.720.0FalseNoneNoneFalseNoneFalse15834.00
3729351138522Nonecode194Warning TapeMtr7.357.35440.0FalseNoneNoneFalseNoneFalse3234.00
3729352138522Nonecode195FLUX COMPENSATED MAGNETIC AMPLIFIER SOFT STARTER SUITABLE FOR L.T.SQUIRREL CAGE MOTOR Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (5), 415V including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start / Stop push button.s. 30 to 37 kW.Each170641.0170641.02.0FalseNoneNoneFalseNoneFalse341282.00
3729353138522Nonecode196Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessaryMtr108.15108.1580.0FalseNoneNoneFalseNoneFalse8652.00
3729354138522Nonecode197Supplying and fixing sheet metal boxes made out of 18 SWG sheet metal with the necessary holes for the cable/conductor as required, with one coat of primer of approved make, etc. 200 x 200 x 65 mmEach365.4365.44.0FalseNoneNoneFalseNoneFalse1461.60
3729355138522Nonecode198Supplying and fixing PVC/metal conduit Deep junction box. 32 mm deep Junction boxEach64.0564.056.0FalseNoneNoneFalseNoneFalse384.30
3729356138522Nonecode199Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit /Gi pipe and plastering ,finishing up to wall surface completeMtr72.4572.4540.0FalseNoneNoneFalseNoneFalse2898.00
3729357138522Nonecode200Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.55qm (Phase & Neutral) & 1x1.0 sqmm Earth wire) FRLS multi strand PVC insulated copper wire. (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switchesEach1086.751086.7510.0FalseNoneNoneFalseNoneFalse10867.50
3729358138522Nonecode201Wiring for lighting/power circuit using one ofF RLSPVCinsulated 1100V grade,multistrand copperwirewithlow conductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. do 6 mm2Mtr96.696.6200.0FalseNoneNoneFalseNoneFalse19320.00
3729359138522Nonecode202Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 6C x 1.5 mm2Mtr127.05127.05200.0FalseNoneNoneFalseNoneFalse25410.00
3729360138522Nonecode203Supplying and fixing surface/flush mountin gun breakable PVC modular box suitable for mounting modular switch plates with due groove cutting inBrick/C.Cwall,including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach181.65181.654.0FalseNoneNoneFalseNoneFalse726.60
3729361138522Nonecode204Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way SwitchEach107.1107.120.0FalseNoneNoneFalseNoneFalse2142.00
3729362138522Nonecode205Supplying of recess mounting non integral type LED W luminaire comprising of pressure decast/extruded aluminium housing with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70 efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/TEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1x1 18W.Each3294.93294.912.0FalseNoneNoneFalseNoneFalse39538.80
3729363138522Nonecode206Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min SKV along with Over voltage/ Overload. short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI =75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 70W.Each7106.47106.47.0FalseNoneNoneFalseNoneFalse49744.80
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17231217020000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17231217020000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17231217020000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17231217020000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17231217020000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17231217150000NoneNoneELIGIBILITYONE.)Any changes/modifications will be notified/updated through eprocurement only. 2.)The Authority reserves the right to accept/reject any or all tenders without assigning any reasons. 3.)Any discrepancies in the tender document shall be brought to the notice of Tender Inviting Authority before the last date 4.)If any, the decision of the Tender Inviting Authority shall be final.5)All documents are to be uploaded through e-portal only. 6)All other conditions as per KW 4 Standard Tender document. 7)The decision of the Tender Inviting Authority shall be final in case of any discrepancies. 8)GST will be paid separately where ever it is applicable. 9.)Work to be carried out as per the direction of Engineer in charge. 10)Bidders are instructed to visit the site before participating in tender. Any objections regarding the items in the Schedule-B shall be brought to the notice of the authority. No objections will be entertained later & work has to be executed in complete manner. 11)Bidders should mention Address for Correspondence, Contact number AND E-mail id in e-portal without fail. 12)Bidders shall submit Original documents as uploaded in e-procurement to the office of Executive Engineer VVWS UGD WEST for verification within 5 days of opening tender. No correspondence shall be made regarding the same from this officeNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess required valid electrical license Of Class-1 From Electrical Inspectorate and should have executed similar electrical works such as Supply Installation Testing And Commissioning Pumping Machineries, Raising Main and Electrical Equipments to Dum & Deaf Sump, Tilaknagara, Mysuru totaling Rs. 27.00 lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneSatisfactorily completed (at least 50% of the contract value) as prime contractor, at least one similar work such as Construction of Sump, Providing of Pumping Machinaries and Distribution Network from Balbhavan Presmises and in Devnur Reservoir of Mysuru City Corporation of value not less than Rs. 135.00 lakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneRegistration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneKey and Critical equipmentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Key and Critical equipment
NoneNoneNoneNoneAchieved in at least two financial years a minimum financial turnover (in all classes of civil engineering works only) of Rs. 540.00 lakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of no less than Rs. 81.00 Lakhs (Unconditional Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Contractor Registration CertificateTrueTechnical Bid
SIMILAR NATURE OF WORKDONE CERTIFICATETrueTechnical Bid
LINE OF CREDITTrueTechnical Bid
Key and Critical equipmentTrueTechnical Bid
Minimum quantity executed of critical items in any one yearTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1723122456000
version0
createdDateNone
modifiedDateNone
blockNumberVAANIVILAS WATER WORKS, WEST DIVISION, YADAVAGIRI
streetNone
cityMYSURU
stateKarnataka
pin570020
tenderRecallDTONone