3729158 | 138522 | None | code01 | Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately. -do- Bituminous course | Cum | 1309.35 | 1309.35 | 74.4 | False | None | None | False | None | False | 97415.64 | 0 |
3729159 | 138522 | None | code02 | Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately. -do- Macadam Road | Cum | 919.8 | 919.8 | 192.3 | False | None | None | False | None | False | 176877.54 | 0 |
3729160 | 138522 | None | code03 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately | Cum | 591.15 | 591.15 | 37.5 | False | None | None | False | None | False | 22168.125 | 0 |
3729161 | 138522 | None | code04 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead. By Manual Means. Cement Concrete Grade M-15 & M-20. | Cum | 979.65 | 979.65 | 2.016 | False | None | None | False | None | False | 1974.9744 | 0 |
3729162 | 138522 | None | code05 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. -do- In all kinds of soils Depth upto 1.5 m. | Cum | 254.1 | 254.1 | 41.256 | False | None | None | False | None | False | 10483.1496 | 0 |
3729163 | 138522 | None | code06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. -do- In all kinds of soils. Depth upto 1.50m. | Cum | 508.2 | 508.2 | 651.6424 | False | None | None | False | None | False | 331164.66768 | 0 |
3729164 | 138522 | None | code07 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- In all kinds of soils. Depth upto 1.50 m | Cum | 275.1 | 275.1 | 1030.58 | False | None | None | False | None | False | 283512.558 | 0 |
3729165 | 138522 | None | code08 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- In all kinds of soils. Depth exceeding 1.5 m, but not exceeding 3 m. | Cum | 347.55 | 347.55 | 352.142 | False | None | None | False | None | False | 122386.9521 | 0 |
3729166 | 138522 | None | code09 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m. | Cum | 476.7 | 476.7 | 108.7006 | False | None | None | False | None | False | 51817.57602 | 0 |
3729167 | 138522 | None | code10 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. -do- Ordinary/soft rock (without requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m. | Cum | 584.85 | 584.85 | 12.0778 | False | None | None | False | None | False | 7063.70133 | 0 |
3729168 | 138522 | None | code11 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. -do- Depth exceeding 1.5m, but not exceeding 3 m. | Cum | 271.95 | 271.95 | 13.5 | False | None | None | False | None | False | 3671.325 | 0 |
3729169 | 138522 | None | code12 | Drum Delineator in Construction Zone:- Provision of metal drum/empty bitumen drum delineator, 300 mm in diameter, 800 mm high, filled with earth for stability, painted in circumferential strips of alternate black and white 100 mm wide fitted with reflectors 3 Nos of 7.5 cm dia, all as per IRC:SP 55:2001. | Each | 800.1 | 800.1 | 20.0 | False | None | None | False | None | False | 16002.0 | 0 |
3729170 | 138522 | None | code13 | Design, manufacturing, supply, errection, trail running, performance test and commissioning of centrifugal pump of approved make conforming to IS:12699 (1989) (Reaffirmed 2009) having specified pump output under specified operating head coupled to HT/LT ,WITH motor of adeuate HP rating operating at suitable KV with flexible coupling, self water lubricated thrust bearings, Strainer, Frame discharge Tee with flanged end for connecting delivery pipe with all other standard accessories and saftey device& all necessary works complete as per specification. -do- 2 Nos of 30 HP | HP | 11025.0 | 11025.0 | 60.0 | False | None | None | False | None | False | 661500.0 | 0 |
3729171 | 138522 | None | code14 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -do- Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 12.3435 | False | None | None | False | None | False | 73409.2632 | 0 |
3729172 | 138522 | None | code15 | Supply and fixing of Cast steel ASTM A 216 Gr.WCB double flanged Dual plate check valve Conforming to API 594 with latest amendments Shaft material shall be SS420/431 and spring shall be spring steel superior grade quality as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking with appurtenances., complete with all lead and lift. The rates are inclusive of cost of Galvanised Bolts and Nuts: For class 150 etc. complete. -do- 250mm | Each | 23144.1 | 23144.1 | 2.0 | False | None | None | False | None | False | 46288.2 | 0 |
3729173 | 138522 | None | code16 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with: -do- Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 | Cum | 6515.25 | 6515.25 | 31.974 | False | None | None | False | None | False | 208318.6035 | 0 |
3729174 | 138522 | None | code17 | Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing).Pipe of 355.6mm dia -7.1mm thick | Rmtr | 8174.25 | 8174.25 | 515.0 | False | None | None | False | None | False | 4209738.75 | 0 |
3729175 | 138522 | None | code18 | Providing and constructing coursed rubble face stone masonry using approved stones in cement mortar 1 : 3 proportion by volume including cost of all materials, machinery, labour, ramps, cleaning, packing mortar and wedging stone chips into joints, curing and all other ancillary operations complete | Cum | 5851.65 | 5851.65 | 53.46 | False | None | None | False | None | False | 312829.209 | 0 |
3729176 | 138522 | None | code19 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron 75 x 75 x 6 mm and M.S. Flat.. with bolts, washers etc and painted with 2 coats of red oxide and then two coats of approved paint. | Mtr | 582.75 | 582.75 | 468.4 | False | None | None | False | None | False | 272960.1 | 0 |
3729177 | 138522 | None | code20 | Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing) for. Pipe bends,branches, tail pieces, reducers etc. for upto 500mm dia pipes | Kgs | 178.5 | 178.5 | 3139.365 | False | None | None | False | None | False | 560376.6525 | 0 |
3729178 | 138522 | None | code21 | Providing 50 mm deep cement mortar pointing to face stone masonry in CM 1 : 2 proportion by volume including cost of all materials, labour, raking-out and cleaning joints, pressing mortar into joints, finishing,
curing and all other ancillary operations complete | Cum | 207.9 | 207.9 | 237.6 | False | None | None | False | None | False | 49397.04 | 0 |
3729179 | 138522 | None | code22 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -do- Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6925.92 | 6925.92 | 13.1767 | False | None | None | False | None | False | 91260.770064 | 0 |
3729180 | 138522 | None | code23 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -do- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 18.1167 | False | None | None | False | None | False | 113925.962115 | 0 |
3729181 | 138522 | None | code24 | Providing, of DI flanged pipe conforming to IS 8329 : 2000 with latest amendments with Cement Mortar Lining (CML) with Portland Slag Cement as per IS 455:1989 and Metallic Zinc Coating as per annexure A
of IS 8329 with finishing layer of Bituminous Coating as per Annexure C of IS 8329 and Flanges: Metallic zinc rich epoxy paint & Bituminous Coating, laying true to line and hoisting in position and aligning to correct plumb including cost of jointing material, conveying to work spot with all lead. -do- For PN 10 250mm | Mtr | 13645.8 | 13645.8 | 12.0 | False | None | None | False | None | False | 163749.6 | 0 |
3729182 | 138522 | None | code25 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. HDPE Grade PE100-PN8.0,250mm dia | Rmtr | 2311.05 | 2311.05 | 480.0 | False | None | None | False | None | False | 1109304.0 | 0 |
3729183 | 138522 | None | code26 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -do- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8865.04 | 8865.04 | 14.31 | False | None | None | False | None | False | 126858.7224 | 0 |
3729184 | 138522 | None | code27 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron 50 x 50 x 6 mm and M.S. Flat.. with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. | Mtr | 414.75 | 414.75 | 531.2 | False | None | None | False | None | False | 220315.2 | 0 |
3729185 | 138522 | None | code28 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-do- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7028.66 | 7028.66 | 43.7492 | False | None | None | False | None | False | 307498.252072 | 0 |
3729186 | 138522 | None | code29 | Manufacturing, supplying, laying in position, aligning, jointing, testing and commissioning of electric resistance welded / submerged arc welded mild steel ( Fe-410 grade ) delivery pipes of specified
diameter and plate thickness with flanged ends wherever required and provided with 1 coat 40 micron thick zinc rich epoxy primer paint and 3 coats 100 micron thick each coat coal tar epoxy paint for
inner surface and 1 coat of 40 micron thick zinc rich epoxy primer paint and 2 coats of 100 micron thick each coat coal tar epoxy paint for outer surface including cost of all materials, machinery, labour,
cutting, bending, welding, finishing, painting,conveying to spot, lowering, aligning, jointing,arranging water for testing, hydraulic testing at fabrication site and after laying and jointing at specified test pressure and all other ancillary operations complete as per specifications and approved drawings. | Rmtr | 150318.0 | 150318.0 | 1.358 | False | None | None | False | None | False | 204131.844 | 0 |
3729187 | 138522 | None | code30 | Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint LNPE 250. | Each | 4516.0 | 4516.0 | 9.0 | False | None | None | False | None | False | 40644.0 | 0 |
3729188 | 138522 | None | code31 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures | Tonne | 82961.55 | 82961.55 | 15.135 | False | None | None | False | None | False | 1255623.05925 | 0 |
3729189 | 138522 | None | code32 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. | Sqm | 883.05 | 883.05 | 213.75 | False | None | None | False | None | False | 188751.9375 | 0 |
3729190 | 138522 | None | code33 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..-do- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7787.01 | 7787.01 | 47.3432 | False | None | None | False | None | False | 368661.971832 | 0 |
3729191 | 138522 | None | code34 | Providing and fixing of ductile iron double flanged swing check valves with slanted seat or with lever weight with straight disc, with metallic corrosion proof and wear resistant seat faces with nickel overlay micro - finished/ Integral seat with body and disc in Ductile Iron in GGG 40/50 shaft of stainless steel and bearings of zinc free bronze and surface protection with epoxy liquid of GSK quality etc complete For PN 10.0. -do- 200mm. | Each | 58895.55 | 58895.55 | 2.0 | False | None | None | False | None | False | 117791.1 | 0 |
3729192 | 138522 | None | code35 | Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Elbow 90 Deg. 250 | Each | 10090.0 | 10090.0 | 4.0 | False | None | None | False | None | False | 40360.0 | 0 |
3729193 | 138522 | None | code36 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN 8, 160mm dia. (P.No. 113, SI.No. 10.2.10 of Common SR for Water supply and UGD 2023-24) | Rmtr | 731.85 | 731.85 | 120.0 | False | None | None | False | None | False | 87822.0 | 0 |
3729194 | 138522 | None | code37 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 m openable length ( total length 90 m), having 50 nos rounds per 6 m length, upto 3 m height of wall with existing angle
iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/mm2 with tape (0.52 mm thick) and weight 43.478 g/m (cost of M.S. angle, C.C. blocks shall be paid separately) | Mtr | 331.8 | 331.8 | 144.0 | False | None | None | False | None | False | 47779.2 | 0 |
3729195 | 138522 | None | code38 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..-do- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11036.02 | 11036.02 | 32.868 | False | None | None | False | None | False | 362731.90536 | 0 |
3729196 | 138522 | None | code39 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts
& nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete. -do- For sluice Valve of PN - 10.0 and 200mm. | Each | 30144.45 | 30144.45 | 8.0 | False | None | None | False | None | False | 241155.6 | 0 |
3729197 | 138522 | None | code40 | Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint LNPE 200mm | Each | 3279.0 | 3279.0 | 8.0 | False | None | None | False | None | False | 26232.0 | 0 |
3729198 | 138522 | None | code41 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 97.1999 | False | None | None | False | None | False | 27147.93207 | 0 |
3729199 | 138522 | None | code42 | Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint LNPE 160mm | Each | 2068.0 | 2068.0 | 2.0 | False | None | None | False | None | False | 4136.0 | 0 |
3729200 | 138522 | None | code43 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In
gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-
Charge. | Kgs | 142.8 | 142.8 | 720.0 | False | None | None | False | None | False | 102816.0 | 0 |
3729201 | 138522 | None | code44 | Providing, fabricating, supplying and fixing at site various diameter MS MJ ends to suit CI / DI pipe as per the sketch . The cost is inclusive of all materials, i.e, rubber ‘O’ rings, flanges, bo lts and nuts, consumables,
hire charges, tools and tackles, welding equipments, lead and lifts, etc. complete as per the instructions of Engineer in charge.For CI / DI pipes of 300mm dia | Each | 5104.05 | 5104.05 | 2.0 | False | None | None | False | None | False | 10208.1 | 0 |
3729202 | 138522 | None | code45 | Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineer-in-charge | Each | 325.5 | 325.5 | 101.736 | False | None | None | False | None | False | 33115.068 | 0 |
3729203 | 138522 | None | code46 | Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing | Each | 3774.75 | 3774.75 | 6.0 | False | None | None | False | None | False | 22648.5 | 0 |
3729204 | 138522 | None | code47 | Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Coupler 250mm | Each | 4325.0 | 4325.0 | 10.0 | False | None | None | False | None | False | 43250.0 | 0 |
3729205 | 138522 | None | code48 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge | Sqm | 38.85 | 38.85 | 504.0 | False | None | None | False | None | False | 19580.4 | 0 |
3729206 | 138522 | None | code49 | Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for
tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 300mm dia and 20mm thick | Each | 4389.0 | 4389.0 | 3.0 | False | None | None | False | None | False | 13167.0 | 0 |
3729207 | 138522 | None | code50 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewe, effluent and water treatment plants, over head tanks, etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 ie. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats @ 0.70 kg per sqm per coat | Sqm | 454.65 | 454.65 | 210.25 | False | None | None | False | None | False | 95590.1625 | 0 |
3729208 | 138522 | None | code51 | Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 200mm dia and 20mm thick. | Each | 2822.4 | 2822.4 | 10.0 | False | None | None | False | None | False | 28224.0 | 0 |
3729209 | 138522 | None | code52 | Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Coupler 160mm | Each | 1366.0 | 1366.0 | 2.0 | False | None | None | False | None | False | 2732.0 | 0 |
3729210 | 138522 | None | code53 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding
and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Sqm | 8376.9 | 8376.9 | 9.18 | False | None | None | False | None | False | 76899.942 | 0 |
3729211 | 138522 | None | code54 | Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for
tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for: Flanges of 400mm dia and 25mm thick | Each | 6941.55 | 6941.55 | 16.0 | False | None | None | False | None | False | 111064.8 | 0 |
3729212 | 138522 | None | code55 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 371.7 | 371.7 | 812.734 | False | None | None | False | None | False | 302093.2278 | 0 |
3729213 | 138522 | None | code56 | Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 100mm dia and 10mm thick | Each | 725.55 | 725.55 | 2.0 | False | None | None | False | None | False | 1451.1 | 0 |
3729214 | 138522 | None | code57 | Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST levied by GOI & GOk in all respect, etc. complete. -do- Coupler 200mm | Each | 2202.0 | 2202.0 | 10.0 | False | None | None | False | None | False | 22020.0 | 0 |
3729215 | 138522 | None | code58 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 450.45 | 450.45 | 504.0 | False | None | None | False | None | False | 227026.8 | 0 |
3729216 | 138522 | None | code59 | Making main bore in CI/DI/MS pipes with approved tools and procedures etc. for:50mm | Each | 369.6 | 369.6 | 2.0 | False | None | None | False | None | False | 739.2 | 0 |
3729217 | 138522 | None | code60 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 2764.65 | 2764.65 | 5.25 | False | None | None | False | None | False | 14514.4125 | 0 |
3729218 | 138522 | None | code61 | Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 150mm dia and 16mm thick. | Each | 1688.4 | 1688.4 | 2.0 | False | None | None | False | None | False | 3376.8 | 0 |
3729219 | 138522 | None | code62 | Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 150mm dia and 12mm thick | Each | 1284.15 | 1284.15 | 2.0 | False | None | None | False | None | False | 2568.3 | 0 |
3729220 | 138522 | None | code63 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 454.65 | 454.65 | 246.24 | False | None | None | False | None | False | 111953.016 | 0 |
3729221 | 138522 | None | code64 | Supply and fixing of Single / Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/50. All internal
parts such as float, shell with appurtenances., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside
colour blue RAL5005. The valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for
discharge of pressurized air during operation. For PN 10.0. For TP Air Valves of 50mm dia. | Each | 29600.55 | 29600.55 | 2.0 | False | None | None | False | None | False | 59201.1 | 0 |
3729222 | 138522 | None | code65 | Top cover of Rolling shutters 1.20 mm thick. | Sqm | 588.0 | 588.0 | 2.7 | False | None | None | False | None | False | 1587.6 | 0 |
3729223 | 138522 | None | code66 | Supply and delivery at site brand new best make pressure guage suitable for centrifugal pump confirming to latest IS standards. pressure guage 100mm. | Each | 686.7 | 686.7 | 3.0 | False | None | None | False | None | False | 2060.1 | 0 |
3729224 | 138522 | None | code67 | Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 250mm dia and 16mm thick | Each | 3123.75 | 3123.75 | 10.0 | False | None | None | False | None | False | 31237.5 | 0 |
3729225 | 138522 | None | code68 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications | Cum | 2816.1 | 2816.1 | 13.536 | False | None | None | False | None | False | 38118.7296 | 0 |
3729226 | 138522 | None | code69 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O“ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For Suilce Valve of PN - 10.0 and 50mm | Each | 5811.75 | 5811.75 | 2.0 | False | None | None | False | None | False | 11623.5 | 0 |
3729227 | 138522 | None | code70 | Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge | Each | 3240.3 | 3240.3 | 1.0 | False | None | None | False | None | False | 3240.3 | 0 |
3729228 | 138522 | None | code71 | Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500Kg WL (Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158:1991 | Each | 18587.1 | 18587.1 | 1.0 | False | None | None | False | None | False | 18587.1 | 0 |
3729229 | 138522 | None | code72 | Providing, fabricaing, supplying and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire charges for tools and tackles, weldiing equipments etc. complete as per instructions of the Engineer in charge for:Flanges of 200mm dia and 16mm thick | Each | 2363.55 | 2363.55 | 11.0 | False | None | None | False | None | False | 25999.05 | 0 |
3729230 | 138522 | None | code73 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O“ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For Suilce Valve of PN - 10.0 and 350mm | Each | 97894.65 | 97894.65 | 3.0 | False | None | None | False | None | False | 293683.95 | 0 |
3729231 | 138522 | None | code74 | Providing and fixing Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 111.3 | 111.3 | 544.57 | False | None | None | False | None | False | 60610.641 | 0 |
3729232 | 138522 | None | code75 | Digging of Pit 2.5 mtr depth for errection of 11mtr long tubular spun pole as per approved Drawing. Hard Soil | Cum | 4070.85 | 4070.85 | 1.0 | False | None | None | False | None | False | 4070.85 | 0 |
3729233 | 138522 | None | code76 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. 250mm Dia. | Each | 48815.55 | 48815.55 | 4.0 | False | None | None | False | None | False | 195262.2 | 0 |
3729234 | 138522 | None | code77 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 496.0 | False | None | None | False | None | False | 46351.2 | 0 |
3729235 | 138522 | None | code78 | Cutting charges only for cutting CI/DI/MS pipes already laid in the ground with necessary approved tools for:350mm dia pipes | Each | 240.45 | 240.45 | 6.0 | False | None | None | False | None | False | 1442.7 | 0 |
3729236 | 138522 | None | code79 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 155.4 | 155.4 | 450.0 | False | None | None | False | None | False | 69930.0 | 0 |
3729237 | 138522 | None | code80 | Providing cement concrete to poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). Base concreting with CC 1:4: 8: Pole base 11mtr spun pole (1000x1000x150mm | Each | 882.0 | 882.0 | 1.0 | False | None | None | False | None | False | 882.0 | 0 |
3729238 | 138522 | None | code81 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. 150mm Dia. | Each | 18364.5 | 18364.5 | 2.0 | False | None | None | False | None | False | 36729.0 | 0 |
3729239 | 138522 | None | code82 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 145.95 | 145.95 | 283.5 | False | None | None | False | None | False | 41376.825 | 0 |
3729240 | 138522 | None | code83 | Excavating of ramming/jacking/driving pit and receiving pit of size 5.00m(length) x 3.00m (breadth), up to 6.00 m depth in all soil strata including shoring and strutting including cutting of Asphalt/CC/Macadam
road surface and removing the excavated stuff with all lead and lifts. The work includes formation of CC/RCC of 1:3:6 with or without 20mm steel with suitable spacing. The work also to receive the impacts driving pushing operation of encasing pipe. The cost includes driving the horizontal bore by pushing/jacking methods (trenchless technology | Each | 182236.95 | 182236.95 | 2.0 | False | None | None | False | None | False | 364473.9 | 0 |
3729241 | 138522 | None | code84 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 28.278 | False | None | None | False | None | False | 45873.9855 | 0 |
3729242 | 138522 | None | code85 | Providing cement concrete to poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). Pole concreting with CC 1:2:4 (without coping): 11 mtrs Spun pole (1000x1000x2500mm) | Each | 14704.2 | 14704.2 | 1.0 | False | None | None | False | None | False | 14704.2 | 0 |
3729243 | 138522 | None | code86 | Installation of product pipe by manual jacking method - Manufacturing, providing, transporting, rolling, lowering, laying & jointing, testing, commissioning of ERW (Electric Resistance Welded), SAW (Submerged
Arc Welded) MS pipe (Fe-410 grade) conforming to IS 3589-2001 with latest ammendments including perfect linking welding of joints to correct position including cost and conveyance of pipes and materials with all lead ,lift, cost of labour, loading and unloading of pipes for the following diameters with specified thickness of plate as noted below including bailing out of water wherever necessary for laying of carrier pipe of suitable dia including inside and outside of casing pipe painted with two coats of Anti corrossive tankmastic paint. Installation of steel pipe by Ramming / Jacking method to cross Railway track / NH /BDA /BBMP/ Other roads/Existing utilities / NALA crossings, filling the gap between casing pipe and carrier pipe with quarry grit using compressor with all necessary equipments, plants etc, complete. Suitable spacers of HDP/ MS or other similar material should be provided in between carrier & casing pipe to prevent carrier pipe forming metallic contact with casing pipe. Note : a. The cost of jacking is inclusive of cost M.S. casing pipe of specified thickness b. The cost of carrying pipe is separate and provision shall be made as per site requirement c. The cost of Jacking includes all leads lifts, cost of consumables, fuel charges, labour. d. The cost of jacking and receving pits shall be proposed seperatelly as per site requirement. -do- Jacking of 600 mm dia & 10mm thick M.S. Casing Pip | Each | 31077.9 | 31077.9 | 70.0 | False | None | None | False | None | False | 2175453.0 | 0 |
3729244 | 138522 | None | code87 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete | Sqm | 1129.8 | 1129.8 | 88.635 | False | None | None | False | None | False | 100139.823 | 0 |
3729245 | 138522 | None | code88 | Providing cement concerete to poles and Guy sets with material and labour including necessary curing
etc., complete | Each | 2331.0 | 2331.0 | 1.0 | False | None | None | False | None | False | 2331.0 | 0 |
3729246 | 138522 | None | code89 | Cutting charges only for cutting CI/DI/HDPE pipes already laid in the ground with necessary approved tools for:200mm dia pipes. | Each | 122.85 | 122.85 | 6.0 | False | None | None | False | None | False | 737.1 | 0 |
3729247 | 138522 | None | code90 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. | Cum | 168.0 | 168.0 | 1491.375 | False | None | None | False | None | False | 250551.0 | 0 |
3729248 | 138522 | None | code91 | Providing and fixing 40mm dia. GI pipe medium duty pipes hand railing 3 rows fixed to RCC 1:2:4 vibrated post of 150x150mm at bottom and 100x150mm at top, placed at 2 Mtrs. intervals for a height of 750mm including curing, painting GI pipes with two coats of anticorrosive steel paint over a primer coat etc. with all lead lift etc. | Sqm | 1393.35 | 1393.35 | 39.5892 | False | None | None | False | None | False | 55161.61182 | 0 |
3729249 | 138522 | None | code92 | Erection of 11mtr long Concrete spun pole in a pit of 2.5 mtr depth.(Mechnised Labour). | Each | 2671.2 | 2671.2 | 1.0 | False | None | None | False | None | False | 2671.2 | 0 |
3729250 | 138522 | None | code93 | Cutting charges only for cutting CI/DI/HDPE pipes already laid in the ground with necessary approved tools for:250mm dia pipes. | Each | 175.35 | 175.35 | 8.0 | False | None | None | False | None | False | 1402.8 | 0 |
3729251 | 138522 | None | code94 | Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification | Sqm | 1756.65 | 1756.65 | 118.692 | False | None | None | False | None | False | 208500.3018 | 0 |
3729252 | 138522 | None | code95 | H - Frame Set for fixing 11kV, 200 Amps SB GOS/400 Amps DB GOS- (For DP structure for providing New GOS for sectionalisation) - GI | Each | 6374.55 | 6374.55 | 2.0 | False | None | None | False | None | False | 12749.1 | 0 |
3729253 | 138522 | None | code96 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 182.7 | 182.7 | 365.583 | False | None | None | False | None | False | 66792.0141 | 0 |
3729254 | 138522 | None | code97 | Erection of H-Frame. | Each | 339.15 | 339.15 | 2.0 | False | None | None | False | None | False | 678.3 | 0 |
3729255 | 138522 | None | code98 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 21.0 | False | None | None | False | None | False | 2535.75 | 0 |
3729256 | 138522 | None | code99 | 11kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018). GOS as per IS-9921, IS-1977 | Each | 9922.5 | 9922.5 | 2.0 | False | None | None | False | None | False | 19845.0 | 0 |
3729257 | 138522 | None | code100 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 O rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. 400mm Dia PN-16 | Each | 175320.6 | 175320.6 | 2.0 | False | None | None | False | None | False | 350641.2 | 0 |
3729258 | 138522 | None | code101 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. -do- For DI/CI puddle flanges of 200mm dia | Each | 3369.45 | 3369.45 | 2.0 | False | None | None | False | None | False | 6738.9 | 0 |
3729259 | 138522 | None | code102 | Fixing of GOS including wiring (11kV SB 200A). | Each | 1159.2 | 1159.2 | 2.0 | False | None | None | False | None | False | 2318.4 | 0 |
3729260 | 138522 | None | code103 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. -do- For DI/CI puddle flanges of 250mm dia | Each | 4735.5 | 4735.5 | 1.0 | False | None | None | False | None | False | 4735.5 | 0 |
3729261 | 138522 | None | code104 | Lightning Aresters 11kV, 5kA, Metal Oxide | Each | 966.0 | 966.0 | 9.0 | False | None | None | False | None | False | 8694.0 | 0 |
3729262 | 138522 | None | code105 | Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and Providing and laying of MDPE pipe (PE80)-PN 12.5 manufactured in accordance with ISO 4427-1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm/ GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. "A" class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making "U" shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on the distribution main pipe with SS / Brass ferrule of size 1/2" x 3/4" and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS). The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles, PE 100 black colour pipe of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter cum flow regulator, water tight cap with O'ring, long spigot for making
bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for drinking water service in WRC - NSF, UK and DVGW certificate, Germany. The Saddle should be manufactured Virgin Compounded PE 100 material. Tapping Tee or Saddles with coupler and compression fittings with cost of GI pipes, as per diagram, all specials such as GI tee, GI elbow, GI coupler, stopper with appurtenances, and brass or SS tap The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of
the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed off to a distance with an initial lead of 10 Kms. etc. complete for the following diameters: (for minimum length of 2m) etc. complete | Each | 6874.35 | 6874.35 | 97.0 | False | None | None | False | None | False | 666811.95 | 0 |
3729263 | 138522 | None | code106 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. -do- For DI/CI puddle flanges of 300mm dia. | Each | 5965.05 | 5965.05 | 2.0 | False | None | None | False | None | False | 11930.1 | 0 |
3729264 | 138522 | None | code107 | Fixing of 3 Nos lightning arrestors including wiring | Each | 124.95 | 124.95 | 3.0 | False | None | None | False | None | False | 374.85 | 0 |
3729265 | 138522 | None | code108 | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including
hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:MS angle of 65 x 65 x 10mm | Each | 5041.05 | 5041.05 | 10.0 | False | None | None | False | None | False | 50410.5 | 0 |
3729266 | 138522 | None | code109 | 11kV, 5KN Composite/Polymeric Pin Insulator (20 m dia FRP Rod) | Each | 215.25 | 215.25 | 9.0 | False | None | None | False | None | False | 1937.25 | 0 |
3729267 | 138522 | None | code110 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.2 | 4.2 | 4000.0 | False | None | None | False | None | False | 16800.0 | 0 |
3729268 | 138522 | None | code111 | 11kV Class, HG Fuse Unit with Solid Core Insulators (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) as per IS-5350 Part-2. Set/3 N | No | 1122.45 | 1122.45 | 3.0 | False | None | None | False | None | False | 3367.35 | 0 |
3729269 | 138522 | None | code112 | Fixing Horn Gap Fuses including fixing of cross arms and wiring | No | 248.85 | 248.85 | 3.0 | False | None | None | False | None | False | 746.55 | 0 |
3729270 | 138522 | None | code113 | ACSR conductor as per IS-398 (Part - 2/1996) Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt : 214 kgs/km | No | 48.54 | 48.54 | 22.5 | False | None | None | False | None | False | 1092.15 | 0 |
3729271 | 138522 | None | code114 | RCC Pole - 9.5 Mtr Long, 350 Kg WL for 33kV Lineas per REC Standard | No | 7884.45 | 7884.45 | 3.0 | False | None | None | False | None | False | 23653.35 | 0 |
3729272 | 138522 | None | code115 | Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing | No | 1188.6 | 1188.6 | 3.0 | False | None | None | False | None | False | 3565.8 | 0 |
3729273 | 138522 | None | code116 | Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth. | No | 1168.65 | 1168.65 | 3.0 | False | None | None | False | None | False | 3505.95 | 0 |
3729274 | 138522 | None | code117 | Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). A) Base Concreting with CC 1:4: 8. a) Pole base for 11/9.5/9/8 Mtr supports (500x650x150mm) | No | 286.65 | 286.65 | 3.0 | False | None | None | False | None | False | 859.95 | 0 |
3729275 | 138522 | None | code118 | Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). B) Pole Concreting with CC 1:2:4 (without coping). a) 9 Mtr support (650x500x1700mm). | Each | 3315.9 | 3315.9 | 3.0 | False | None | None | False | None | False | 9947.7 | 0 |
3729276 | 138522 | None | code119 | Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation). C) Providing Coping for Pole with CC 1:2:4 (As per actuals). a) 150 mm all around the Pole for an height of 300 mm for RCC, PSCC Pole | Each | 569.1 | 569.1 | 3.0 | False | None | None | False | None | False | 1707.3 | 0 |
3729277 | 138522 | None | code120 | DP Set (2 Pole Strucrure Kit) as per IS-1977. For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - GI. | Each | 9306.15 | 9306.15 | 1.0 | False | None | None | False | None | False | 9306.15 | 0 |
3729278 | 138522 | None | code121 | Erection of 2 Pole Structure using RCC/PSCC Pole 9 to 10 Mtr long. | Each | 4340.7 | 4340.7 | 1.0 | False | None | None | False | None | False | 4340.7 | 0 |
3729279 | 138522 | None | code122 | DISC Insulator 45 kN Porcelain. | Each | 535.5 | 535.5 | 6.0 | False | None | None | False | None | False | 3213.0 | 0 |
3729280 | 138522 | None | code123 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Each | 255645.6 | 255645.6 | 1.0 | False | None | None | False | None | False | 255645.6 | 0 |
3729281 | 138522 | None | code124 | Load Break Switch with Panel. | Each | 76900.95 | 76900.95 | 1.0 | False | None | None | False | None | False | 76900.95 | 0 |
3729282 | 138522 | None | code125 | One Breaker Panel with Copper Busbar 350 MVA, 630 Amps as per IEC-62271/IS-3427. | Each | 740735.1 | 740735.1 | 1.0 | False | None | None | False | None | False | 740735.1 | 0 |
3729283 | 138522 | None | code126 | Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment.Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely | Each | 31879.05 | 31879.05 | 3.0 | False | None | None | False | None | False | 95637.15 | 0 |
3729284 | 138522 | None | code127 | Erection of HT metering Cubicle on Platform | Each | 1936.2 | 1936.2 | 1.0 | False | None | None | False | None | False | 1936.2 | 0 |
3729285 | 138522 | None | code128 | Supply of Transformer with copper windings & oil, cable termination type on both HT & LT outdoor type. do 250 kVA, 11 kV/433 V, 3 phase Dyn11. | Each | 444626.7 | 444626.7 | 1.0 | False | None | None | False | None | False | 444626.7 | 0 |
3729286 | 138522 | None | code129 | Erection of Transformer. do 100 kVA, 11 kV/433 V, 3 phase Dyn11 | Each | 19521.6 | 19521.6 | 1.0 | False | None | None | False | None | False | 19521.6 | 0 |
3729287 | 138522 | None | code130 | Erection of Transformer. do 250 kVA, 11 kV/433 V, 3 phase Dyn11. | Each | 21925.05 | 21925.05 | 1.0 | False | None | None | False | None | False | 21925.05 | 0 |
3729288 | 138522 | None | code131 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. Do 95 Sqmm, (54 GI Wires - 2.5 mm Dia). | Km | 934149.3 | 934149.3 | 0.44 | False | None | None | False | None | False | 411025.692 | 0 |
3729289 | 138522 | None | code132 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. -do- HT Cable 3x95 to 150 Sqmm | Km | 64388.1 | 64388.1 | 0.44 | False | None | None | False | None | False | 28330.764 | 0 |
3729290 | 138522 | None | code133 | GI Pipe - 150 mm Dia | No | 1360.8 | 1360.8 | 24.0 | False | None | None | False | None | False | 32659.2 | 0 |
3729291 | 138522 | None | code134 | Laying the GI Pipe 80mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete. | No | 97.65 | 97.65 | 12.0 | False | None | None | False | None | False | 1171.8 | 0 |
3729292 | 138522 | None | code135 | RCC Hume Pipes 2000mm long 150mm dia. | No | 322.35 | 322.35 | 30.0 | False | None | None | False | None | False | 9670.5 | 0 |
3729293 | 138522 | None | code136 | Collars for RCC Hume Pipe 150 mm Dia | No | 86.1 | 86.1 | 30.0 | False | None | None | False | None | False | 2583.0 | 0 |
3729294 | 138522 | None | code137 | Laying and Jointing the pipes (100-150 mm), dia including lowering in Position: Fixing Collars etc., Joining with mud mortor complete. do RC | No | 72.45 | 72.45 | 60.0 | False | None | None | False | None | False | 4347.0 | 0 |
3729295 | 138522 | None | code138 | Burnt Brick (Class 35 Modular) | No | 8.4 | 8.4 | 500.0 | False | None | None | False | None | False | 4200.0 | 0 |
3729296 | 138522 | None | code139 | Cable Covering Tiles 125x250x40 mm | No | 10.76 | 10.76 | 600.0 | False | None | None | False | None | False | 6456.0 | 0 |
3729297 | 138522 | None | code140 | Covering cable with Tiles. | Km | 4585.35 | 4585.35 | 0.2 | False | None | None | False | None | False | 917.07 | 0 |
3729298 | 138522 | None | code141 | Artificial Sand/Manufacture Sand. | Cum | 1562.4 | 1562.4 | 0.011 | False | None | None | False | None | False | 17.1864 | 0 |
3729299 | 138522 | None | code142 | Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. | Km | 15550.5 | 15550.5 | 0.22 | False | None | None | False | None | False | 3421.11 | 0 |
3729300 | 138522 | None | code143 | Caution/Danger Board. | No | 157.5 | 157.5 | 10.0 | False | None | None | False | None | False | 1575.0 | 0 |
3729301 | 138522 | None | code144 | Fixing Danger Board | No | 84.0 | 84.0 | 10.0 | False | None | None | False | None | False | 840.0 | 0 |
3729302 | 138522 | None | code145 | Spun Pole Painting (supplying and applying two coats of enamel paints to 11Mtrs spun pole) and painting all the metal parts of the structure with two coats of aluminium paint over primer. | No | 10830.75 | 10830.75 | 1.0 | False | None | None | False | None | False | 10830.75 | 0 |
3729303 | 138522 | None | code146 | Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable. do 3x95 Sqmm | Set | 4270.35 | 4270.35 | 16.0 | False | None | None | False | None | False | 68325.6 | 0 |
3729304 | 138522 | None | code147 | Heat Shrinkable Type Transition Jointing Kit for XLPE Cable. do 3x95 Sqmm | Set | 10758.3 | 10758.3 | 2.0 | False | None | None | False | None | False | 21516.6 | 0 |
3729305 | 138522 | None | code148 | Making and Fixing pot head for HT Cable only. Heat shrinkable Type Terminations. do 3x95 to 3x150 Sqmm. | Set | 2790.9 | 2790.9 | 16.0 | False | None | None | False | None | False | 44654.4 | 0 |
3729306 | 138522 | None | code149 | Making and Fixing pot head for HT Cable only. Heat shrinkable Straight Through Joint. do 3x95 to 3x150 Sqmm | Set | 2990.4 | 2990.4 | 2.0 | False | None | None | False | None | False | 5980.8 | 0 |
3729307 | 138522 | None | code150 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr. | Cum | 60.9 | 60.9 | 140.0 | False | None | None | False | None | False | 8526.0 | 0 |
3729308 | 138522 | None | code151 | Digging of Pit for providing GI Pipe type Earthing. do Hard Soil. | Per Pit | 3139.5 | 3139.5 | 3.0 | False | None | None | False | None | False | 9418.5 | 0 |
3729309 | 138522 | None | code152 | Supply of Pipe type earthing Material. GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | No | 780.15 | 780.15 | 3.0 | False | None | None | False | None | False | 2340.45 | 0 |
3729310 | 138522 | None | code153 | Supply of Pipe type earthing Material. Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. | No | 709.8 | 709.8 | 3.0 | False | None | None | False | None | False | 2129.4 | 0 |
3729311 | 138522 | None | code154 | Supply of Pipe type earthing Material. Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 325.5 | 325.5 | 3.0 | False | None | None | False | None | False | 976.5 | 0 |
3729312 | 138522 | None | code155 | Providing GI Pipe Earthing (Excluding digging of pits). | Per Pit | 199.5 | 199.5 | 3.0 | False | None | None | False | None | False | 598.5 | 0 |
3729313 | 138522 | None | code156 | Route & Joint indicating slab with MS Anchor rod | No | 139.65 | 139.65 | 10.0 | False | None | None | False | None | False | 1396.5 | 0 |
3729314 | 138522 | None | code157 | Fixing of Route Joint Indicating Slab | No | 121.8 | 121.8 | 10.0 | False | None | None | False | None | False | 1218.0 | 0 |
3729315 | 138522 | None | code158 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Shortcircuit with adjustable thermal magnetic release, Micro processor release shall have Earth Fault as perIS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. do FOUR Pole 250 A 25 kA | No | 22460.55 | 22460.55 | 1.0 | False | None | None | False | None | False | 22460.55 | 0 |
3729316 | 138522 | None | code159 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panelboard using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Shortcircuit with adjustable thermal magnetic release, Micro processor release shall have Earth Fault as perIS/IEC60947-2. (Icu 100 lcs). In 4P MCCB, all Poles should have protection for Short Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. -do- FOUR Pole 100 A 25 kA | No | 8911.35 | 8911.35 | 3.0 | False | None | None | False | None | False | 26734.05 | 0 |
3729317 | 138522 | None | code160 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT. | No | 1788.15 | 1788.15 | 1.0 | False | None | None | False | None | False | 1788.15 | 0 |
3729318 | 138522 | None | code161 | Supplying fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross- 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. do 50-63 A TPN | No | 3242.4 | 3242.4 | 6.0 | False | None | None | False | None | False | 19454.4 | 0 |
3729319 | 138522 | None | code162 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439-3 and IK09 tested as per IS/IEC62262 with minimum IP43 protection provided with Polyurethane(PUR )gasket, with suitable earthing system, on wall/ woodboard/ flushmounting using required clA, bolts, nuts, etc. with provision for fixing of suitable type capacity MCCBs as an incomer for 3phase Double door with necessary bus bar completely wired to use on 440V 3phase 4wire powder coated paintingetc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. do 8 Way. | No | 13235.25 | 13235.25 | 1.0 | False | None | None | False | None | False | 13235.25 | 0 |
3729320 | 138522 | None | code163 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS2834. 3phase, 400/440V grade, for power factor improvement of rotating machineries like induction motor. | Kvar | 504.0 | 504.0 | 40.0 | False | None | None | False | None | False | 20160.0 | 0 |
3729321 | 138522 | None | code164 | Supplying, fixing and wiring Automatic PowerFactor controller circuit unit fully, static units controlled by 14stage micro processor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and voltage, to connect/disconnect banks, with automatic recognition or withstand ard programs | Each | 22722.0 | 22722.0 | 2.0 | False | None | None | False | None | False | 45444.0 | 0 |
3729322 | 138522 | None | code165 | Supplying 250 A 4 x 30 x 10 mm Aluminium Strips rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., completel. | Mtr | 3606.75 | 3606.75 | 12.0 | False | None | None | False | None | False | 43281.0 | 0 |
3729323 | 138522 | None | code166 | Supplying and fixing angle iron frame work fabricated out of M.S.angle iron. and M.S.Flat. with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 100 x 50 x 6 mm C channel | Mtr | 793.8 | 793.8 | 20.0 | False | None | None | False | None | False | 15876.0 | 0 |
3729324 | 138522 | None | code167 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sqm | 0.52 | 0.52 | 200000.0 | False | None | None | False | None | False | 104000.0 | 0 |
3729325 | 138522 | None | code168 | Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor upto 20 HP capacitie | Each | 949.22 | 949.22 | 2.0 | False | None | None | False | None | False | 1898.44 | 0 |
3729326 | 138522 | None | code169 | COPPER CONTROL CABLE : 2C x 2.5 Sq mm | Mtr | 98.7 | 98.7 | 50.0 | False | None | None | False | None | False | 4935.0 | 0 |
3729327 | 138522 | None | code170 | COPPER CONTROL CABLE : 2C x 6 Sq mm | Mtr | 161.7 | 161.7 | 50.0 | False | None | None | False | None | False | 8085.0 | 0 |
3729328 | 138522 | None | code171 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50HzAC with latest micro controller based, digital read out of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board | Each | 9717.75 | 9717.75 | 2.0 | False | None | None | False | None | False | 19435.5 | 0 |
3729329 | 138522 | None | code172 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. do 32-40A 4 pole. | Each | 5404.35 | 5404.35 | 1.0 | False | None | None | False | None | False | 5404.35 | 0 |
3729330 | 138522 | None | code173 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board | Each | 474.6 | 474.6 | 3.0 | False | None | None | False | None | False | 1423.8 | 0 |
3729331 | 138522 | None | code174 | Supplying, fixing and wiring 0 to 100A Direct Reading AC analog type Ammeter. | Each | 550.2 | 550.2 | 3.0 | False | None | None | False | None | False | 1650.6 | 0 |
3729332 | 138522 | None | code175 | Supplying, fixing and wiring rotary selectors with suitable for Ammeter. | Each | 210.0 | 210.0 | 3.0 | False | None | None | False | None | False | 630.0 | 0 |
3729333 | 138522 | None | code176 | Supplying, fixing and wiring rotary selectors witch suitable forVoltmeter. | Each | 168.0 | 168.0 | 3.0 | False | None | None | False | None | False | 504.0 | 0 |
3729334 | 138522 | None | code177 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound | Each | 590.1 | 590.1 | 6.0 | False | None | None | False | None | False | 3540.6 | 0 |
3729335 | 138522 | None | code178 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 540.75 | 540.75 | 12.0 | False | None | None | False | None | False | 6489.0 | 0 |
3729336 | 138522 | None | code179 | Supplying of multi function digital meter with three line backlight CD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3phase ,4wire LT network with IP54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. | Each | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 |
3729337 | 138522 | None | code180 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should been closed in chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layer so salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 4468.8 | 4468.8 | 15.0 | False | None | None | False | None | False | 67032.0 | 0 |
3729338 | 138522 | None | code181 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers | No | 5085.15 | 5085.15 | 1.0 | False | None | None | False | None | False | 5085.15 | 0 |
3729339 | 138522 | None | code182 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. do 32 | No | 4294.5 | 4294.5 | 1.0 | False | None | None | False | None | False | 4294.5 | 0 |
3729340 | 138522 | None | code183 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. do 50 Sqmm, 3.5 Core, | Km | 187921.65 | 187921.65 | 0.16 | False | None | None | False | None | False | 30067.464 | 0 |
3729341 | 138522 | None | code184 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. do 95 Sqmm, 3.5 Core | Km | 391875.75 | 391875.75 | 0.06 | False | None | None | False | None | False | 23512.545 | 0 |
3729342 | 138522 | None | code185 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. -do- LT Cable 35 to 95 Sqmm | Km | 32695.95 | 32695.95 | 0.12 | False | None | None | False | None | False | 3923.514 | 0 |
3729343 | 138522 | None | code186 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable. Up to 4C x 50 Sqmm | Set | 340.2 | 340.2 | 12.0 | False | None | None | False | None | False | 4082.4 | 0 |
3729344 | 138522 | None | code187 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable. 3.5 x 70/95/120 Sqmm | Set | 401.1 | 401.1 | 4.0 | False | None | None | False | None | False | 1604.4 | 0 |
3729345 | 138522 | None | code188 | Making and Fixing pot head for LT Cable only. Heat shrinkable Straight Through Joint. do 35 to 95 Sqmm | Set | 298.2 | 298.2 | 4.0 | False | None | None | False | None | False | 1192.8 | 0 |
3729346 | 138522 | None | code189 | Making and Fixing pot head for LT Cable only. Heat shrinkable Type Terminations. do 35 to 95 Sqmm | Set | 199.5 | 199.5 | 12.0 | False | None | None | False | None | False | 2394.0 | 0 |
3729347 | 138522 | None | code190 | Fixing foundation frame of channels and angle iron welding fixing in concrete aligning the RMU/PANEL on foundation bed, assembly of units, connecting Bus Bars from panel to panel initial filling of oil etc., complete. do 1 Panel. | No | 5084.1 | 5084.1 | 3.0 | False | None | None | False | None | False | 15252.3 | 0 |
3729348 | 138522 | None | code191 | Fixing of GPRS Modems with Accessories | Each | 1413.3 | 1413.3 | 1.0 | False | None | None | False | None | False | 1413.3 | 0 |
3729349 | 138522 | None | code192 | Laying of control cables from equipment to control panels | Mtr | 15.75 | 15.75 | 100.0 | False | None | None | False | None | False | 1575.0 | 0 |
3729350 | 138522 | None | code193 | Supplying & Laying cable trays including welding, fixing of supports. | Mtr | 791.7 | 791.7 | 20.0 | False | None | None | False | None | False | 15834.0 | 0 |
3729351 | 138522 | None | code194 | Warning Tape | Mtr | 7.35 | 7.35 | 440.0 | False | None | None | False | None | False | 3234.0 | 0 |
3729352 | 138522 | None | code195 | FLUX COMPENSATED MAGNETIC AMPLIFIER SOFT STARTER SUITABLE FOR L.T.SQUIRREL CAGE MOTOR Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (5), 415V including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start / Stop push button.s. 30 to 37 kW. | Each | 170641.0 | 170641.0 | 2.0 | False | None | None | False | None | False | 341282.0 | 0 |
3729353 | 138522 | None | code196 | Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Mtr | 108.15 | 108.15 | 80.0 | False | None | None | False | None | False | 8652.0 | 0 |
3729354 | 138522 | None | code197 | Supplying and fixing sheet metal boxes made out of 18 SWG sheet metal with the necessary holes for the cable/conductor as required, with one coat of primer of approved make, etc. 200 x 200 x 65 mm | Each | 365.4 | 365.4 | 4.0 | False | None | None | False | None | False | 1461.6 | 0 |
3729355 | 138522 | None | code198 | Supplying and fixing PVC/metal conduit Deep junction box. 32 mm deep Junction box | Each | 64.05 | 64.05 | 6.0 | False | None | None | False | None | False | 384.3 | 0 |
3729356 | 138522 | None | code199 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit /Gi pipe and plastering ,finishing up to wall surface complete | Mtr | 72.45 | 72.45 | 40.0 | False | None | None | False | None | False | 2898.0 | 0 |
3729357 | 138522 | None | code200 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.55qm (Phase & Neutral) & 1x1.0 sqmm Earth wire) FRLS multi strand PVC insulated copper wire. (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches | Each | 1086.75 | 1086.75 | 10.0 | False | None | None | False | None | False | 10867.5 | 0 |
3729358 | 138522 | None | code201 | Wiring for lighting/power circuit using one ofF RLSPVCinsulated 1100V grade,multistrand copperwirewithlow conductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. do 6 mm2 | Mtr | 96.6 | 96.6 | 200.0 | False | None | None | False | None | False | 19320.0 | 0 |
3729359 | 138522 | None | code202 | Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 6C x 1.5 mm2 | Mtr | 127.05 | 127.05 | 200.0 | False | None | None | False | None | False | 25410.0 | 0 |
3729360 | 138522 | None | code203 | Supplying and fixing surface/flush mountin gun breakable PVC modular box suitable for mounting modular switch plates with due groove cutting inBrick/C.Cwall,including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 181.65 | 181.65 | 4.0 | False | None | None | False | None | False | 726.6 | 0 |
3729361 | 138522 | None | code204 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch | Each | 107.1 | 107.1 | 20.0 | False | None | None | False | None | False | 2142.0 | 0 |
3729362 | 138522 | None | code205 | Supplying of recess mounting non integral type LED W luminaire comprising of pressure decast/extruded aluminium housing with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70 efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/TEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1x1 18W. | Each | 3294.9 | 3294.9 | 12.0 | False | None | None | False | None | False | 39538.8 | 0 |
3729363 | 138522 | None | code206 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min SKV along with Over voltage/ Overload. short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI =75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 70W. | Each | 7106.4 | 7106.4 | 7.0 | False | None | None | False | None | False | 49744.8 | 0 |