| 3790528 | 143346 | None | code01 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m | Cum | 105.06 | 105.06 | 2621.15 | False | None | None | False | None | False | 275378.019 | 0 |
| 3790529 | 143346 | None | code02 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In all kinds of soils Depth Depth 3 m to 6 m | Cum | 120.51 | 120.51 | 448.18 | False | None | None | False | None | False | 54010.1718 | 0 |
| 3790530 | 143346 | None | code03 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 373.89 | 373.89 | 640.28 | False | None | None | False | None | False | 239394.2892 | 0 |
| 3790531 | 143346 | None | code04 | Compacting original ground supporting embankment : Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OmC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction | Cum | 108.15 | 108.15 | 138.31 | False | None | None | False | None | False | 14958.2265 | 0 |
| 3790532 | 143346 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 1064.0 | False | None | None | False | None | False | 291514.72 | 0 |
| 3790533 | 143346 | None | code06 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | Cum | 87.55 | 87.55 | 1485.53 | False | None | None | False | None | False | 130058.1515 | 0 |
| 3790534 | 143346 | None | code07 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20per E.C. / Lindane 20 E.C. 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 121.54 | 121.54 | 1096.87 | False | None | None | False | None | False | 133313.5798 | 0 |
| 3790535 | 143346 | None | code08 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5833.92 | 5833.92 | 226.52 | False | None | None | False | None | False | 1321499.5584 | 0 |
| 3790536 | 143346 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7229.49 | 7229.49 | 525.45 | False | None | None | False | None | False | 3798735.5205 | 0 |
| 3790537 | 143346 | None | code10 | Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 1.52 | False | None | None | False | None | False | 10002.6184 | 0 |
| 3790538 | 143346 | None | code11 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates.
a) Column upto Plinth level | Cum | 11805.24 | 11805.24 | 18.14 | False | None | None | False | None | False | 214147.0536 | 0 |
| 3790539 | 143346 | None | code12 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates.
b) Beams | Cum | 10416.39 | 10416.39 | 63.45 | False | None | None | False | None | False | 660919.9455 | 0 |
| 3790540 | 143346 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates.
a) Column | Cum | 12269.26 | 12269.26 | 224.55 | False | None | None | False | None | False | 2755062.333 | 0 |
| 3790541 | 143346 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates.
b) Beams | Cum | 11547.54 | 11547.54 | 170.6 | False | None | None | False | None | False | 1970010.324 | 0 |
| 3790542 | 143346 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates.
c) Slab and Ramp | Cum | 10825.82 | 10825.82 | 384.31 | False | None | None | False | None | False | 4160470.8842 | 0 |
| 3790543 | 143346 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m20 Design mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6828.9 | 6828.9 | 157.37 | False | None | None | False | None | False | 1074663.993 | 0 |
| 3790544 | 143346 | None | code17 | Supplying, fitting and placing TmT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 92140.71 | 92140.71 | 191.51 | False | None | None | False | None | False | 17645867.3721 | 0 |
| 3790545 | 143346 | None | code18 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with Cm 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1349.3 | 1349.3 | 1377.99 | False | None | None | False | None | False | 1859321.907 | 0 |
| 3790546 | 143346 | None | code19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering | Sqm | 382.13 | 382.13 | 1746.88 | False | None | None | False | None | False | 667535.2544 | 0 |
| 3790547 | 143346 | None | code20 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Internal Wall Plastering) | Sqm | 287.37 | 287.37 | 2155.3 | False | None | None | False | None | False | 619368.561 | 0 |
| 3790548 | 143346 | None | code21 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Ceiling) | Sqm | 217.33 | 217.33 | 1515.05 | False | None | None | False | None | False | 329265.8165 | 0 |
| 3790549 | 143346 | None | code22 | Providing mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 127928.06 | 127928.06 | 1.72 | False | None | None | False | None | False | 220036.2632 | 0 |
| 3790550 | 143346 | None | code23 | Providing and fixing in position fully panelled mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 7103.91 | 7103.91 | 55.2 | False | None | None | False | None | False | 392135.832 | 0 |
| 3790551 | 143346 | None | code24 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1046.48 | 1046.48 | 23.0 | False | None | None | False | None | False | 24069.04 | 0 |
| 3790552 | 143346 | None | code25 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | No | 283.25 | 283.25 | 92.0 | False | None | None | False | None | False | 26059.0 | 0 |
| 3790553 | 143346 | None | code26 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10mm | Each | 360.5 | 360.5 | 69.0 | False | None | None | False | None | False | 24874.5 | 0 |
| 3790554 | 143346 | None | code27 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete | No | 1083.56 | 1083.56 | 23.0 | False | None | None | False | None | False | 24921.88 | 0 |
| 3790555 | 143346 | None | code28 | Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm | No | 256.47 | 256.47 | 54.0 | False | None | None | False | None | False | 13849.38 | 0 |
| 3790556 | 143346 | None | code29 | Providing and fixing m.S. grills of required pattern in frames of windows etc. with m.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kgs | 188.49 | 188.49 | 2053.8 | False | None | None | False | None | False | 387120.762 | 0 |
| 3790557 | 143346 | None | code30 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made) | Sqm | 5890.57 | 5890.57 | 48.3 | False | None | None | False | None | False | 284514.531 | 0 |
| 3790558 | 143346 | None | code31 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates. d. Chajja | Cum | 10464.95 | 10464.95 | 7.52 | False | None | None | False | None | False | 78696.424 | 0 |
| 3790559 | 143346 | None | code32 | Providing and laying cinder concrete in cement 1:15 ( 1 cement 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2077.51 | 2077.51 | 5.13 | False | None | None | False | None | False | 10657.6263 | 0 |
| 3790560 | 143346 | None | code33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with Cm 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications | Sqm | 1137.12 | 1137.12 | 41.09 | False | None | None | False | None | False | 46724.2608 | 0 |
| 3790561 | 143346 | None | code34 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 142216.22 | 142216.22 | 0.39 | False | None | None | False | None | False | 55464.3258 | 0 |
| 3790562 | 143346 | None | code35 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures | Sqm | 7667.32 | 7667.32 | 18.0 | False | None | None | False | None | False | 138011.76 | 0 |
| 3790563 | 143346 | None | code36 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows and other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with m.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm | m | 786.92 | 786.92 | 57.0 | False | None | None | False | None | False | 44854.44 | 0 |
| 3790564 | 143346 | None | code37 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness For Toilets | Sqm | 3589.55 | 3589.55 | 15.75 | False | None | None | False | None | False | 56535.4125 | 0 |
| 3790565 | 143346 | None | code38 | Providing and fixing of 2.5 track x 2 panel sliding windows made out of multi chambered UPVC(matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) | Sqm | 6747.53 | 6747.53 | 57.0 | False | None | None | False | None | False | 384609.21 | 0 |
| 3790566 | 143346 | None | code39 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400per and tensile strength greater than 2mPa as per ASTm D412. The waterproofing membrane to be applied in 2coats at 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer at 150 g/m2 and protection with 120 gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making covering at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 841.51 | 841.51 | 49.6 | False | None | None | False | None | False | 41738.896 | 0 |
| 3790567 | 143346 | None | code40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes | m | 318.27 | 318.27 | 15.0 | False | None | None | False | None | False | 4774.05 | 0 |
| 3790568 | 143346 | None | code41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes | m | 390.37 | 390.37 | 80.0 | False | None | None | False | None | False | 31229.6 | 0 |
| 3790569 | 143346 | None | code42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes | m | 491.31 | 491.31 | 40.0 | False | None | None | False | None | False | 19652.4 | 0 |
| 3790570 | 143346 | None | code43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes | m | 573.71 | 573.71 | 12.0 | False | None | None | False | None | False | 6884.52 | 0 |
| 3790571 | 143346 | None | code44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 25 mm nominal dia Pipes | m | 304.88 | 304.88 | 45.0 | False | None | None | False | None | False | 13719.6 | 0 |
| 3790572 | 143346 | None | code45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 32 mm nominal dia Pipes | m | 383.16 | 383.16 | 30.0 | False | None | None | False | None | False | 11494.8 | 0 |
| 3790573 | 143346 | None | code46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 40 mm nominal dia Pipes | m | 491.31 | 491.31 | 10.0 | False | None | None | False | None | False | 4913.1 | 0 |
| 3790574 | 143346 | None | code47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 50 mm nominal dia Pipes | m | 742.63 | 742.63 | 25.0 | False | None | None | False | None | False | 18565.75 | 0 |
| 3790575 | 143346 | None | code48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 65 mm nominal dia Pipes | m | 1442.0 | 1442.0 | 10.0 | False | None | None | False | None | False | 14420.0 | 0 |
| 3790576 | 143346 | None | code49 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :. 25 mm nominal bore | No | 565.47 | 565.47 | 2.0 | False | None | None | False | None | False | 1130.94 | 0 |
| 3790577 | 143346 | None | code50 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore | No | 615.94 | 615.94 | 3.0 | False | None | None | False | None | False | 1847.82 | 0 |
| 3790578 | 143346 | None | code51 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore | No | 723.06 | 723.06 | 3.0 | False | None | None | False | None | False | 2169.18 | 0 |
| 3790579 | 143346 | None | code52 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore | No | 880.65 | 880.65 | 3.0 | False | None | None | False | None | False | 2641.95 | 0 |
| 3790580 | 143346 | None | code53 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore | No | 1453.33 | 1453.33 | 1.0 | False | None | None | False | None | False | 1453.33 | 0 |
| 3790581 | 143346 | None | code54 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover. | Each | 5617.62 | 5617.62 | 7.0 | False | None | None | False | None | False | 39323.34 | 0 |
| 3790582 | 143346 | None | code55 | Providing and fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with m.S flats 32x6 mm etc and painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. | Each | 2020.86 | 2020.86 | 7.0 | False | None | None | False | None | False | 14146.02 | 0 |
| 3790583 | 143346 | None | code56 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore Vertical | No | 952.75 | 952.75 | 1.0 | False | None | None | False | None | False | 952.75 | 0 |
| 3790584 | 143346 | None | code57 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (For 2000 liters capacity) | l | 9.27 | 9.27 | 2000.0 | False | None | None | False | None | False | 18540.0 | 0 |
| 3790585 | 143346 | None | code58 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 32mm dia, 10kg/sqcm and class 5 | m | 69.01 | 69.01 | 30.0 | False | None | None | False | None | False | 2070.3 | 0 |
| 3790586 | 143346 | None | code59 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 50mm dia, 6kg/sqcm and class 5 | m | 104.03 | 104.03 | 25.0 | False | None | None | False | None | False | 2600.75 | 0 |
| 3790587 | 143346 | None | code60 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 75mm dia, 6kg/sqcm and class 3 | m | 226.6 | 226.6 | 75.0 | False | None | None | False | None | False | 16995.0 | 0 |
| 3790588 | 143346 | None | code61 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 110mm dia, 6kg/sqcm and class 3 | m | 423.33 | 423.33 | 50.0 | False | None | None | False | None | False | 21166.5 | 0 |
| 3790589 | 143346 | None | code62 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 140mm dia, 6kg/sqcm and class 3 | m | 601.52 | 601.52 | 40.0 | False | None | None | False | None | False | 24060.8 | 0 |
| 3790590 | 143346 | None | code63 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails and bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m | Cum | 269.86 | 269.86 | 75.0 | False | None | None | False | None | False | 20239.5 | 0 |
| 3790591 | 143346 | None | code64 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 125.0 | False | None | None | False | None | False | 20600.0 | 0 |
| 3790592 | 143346 | None | code65 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete | Each | 20716.39 | 20716.39 | 1.0 | False | None | None | False | None | False | 20716.39 | 0 |
| 3790593 | 143346 | None | code66 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thick | m | 67.98 | 67.98 | 700.0 | False | None | None | False | None | False | 47586.0 | 0 |
| 3790594 | 143346 | None | code67 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thick | m | 80.34 | 80.34 | 1000.0 | False | None | None | False | None | False | 80340.0 | 0 |
| 3790595 | 143346 | None | code68 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5 mm thick | m | 106.09 | 106.09 | 200.0 | False | None | None | False | None | False | 21218.0 | 0 |
| 3790596 | 143346 | None | code69 | Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick | m | 70.04 | 70.04 | 340.0 | False | None | None | False | None | False | 23813.6 | 0 |
| 3790597 | 143346 | None | code70 | Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 81.37 | 81.37 | 450.0 | False | None | None | False | None | False | 36616.5 | 0 |
| 3790598 | 143346 | None | code71 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3mtr from tapping point to out let via switch box | Point | 277.07 | 277.07 | 18.0 | False | None | None | False | None | False | 4987.26 | 0 |
| 3790599 | 143346 | None | code72 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. medium point above 3mtr upto 6mtr from tapping point to out let via switch box | Point | 390.37 | 390.37 | 45.0 | False | None | None | False | None | False | 17566.65 | 0 |
| 3790600 | 143346 | None | code73 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6mtr upto 10mtr from tapping point to out let via switch box | Point | 571.65 | 571.65 | 96.0 | False | None | None | False | None | False | 54878.4 | 0 |
| 3790601 | 143346 | None | code74 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switches | Point | 697.31 | 697.31 | 2.0 | False | None | None | False | None | False | 1394.62 | 0 |
| 3790602 | 143346 | None | code75 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6mts upto 10mtr from tapping point to out let via switches box | Point | 1018.67 | 1018.67 | 3.0 | False | None | None | False | None | False | 3056.01 | 0 |
| 3790603 | 143346 | None | code76 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 Way | Each | 142.14 | 142.14 | 55.0 | False | None | None | False | None | False | 7817.7 | 0 |
| 3790604 | 143346 | None | code77 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 Way | Each | 163.77 | 163.77 | 30.0 | False | None | None | False | None | False | 4913.1 | 0 |
| 3790605 | 143346 | None | code78 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 Way | Each | 182.31 | 182.31 | 10.0 | False | None | None | False | None | False | 1823.1 | 0 |
| 3790606 | 143346 | None | code79 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 Way | Each | 226.6 | 226.6 | 10.0 | False | None | None | False | None | False | 2266.0 | 0 |
| 3790607 | 143346 | None | code80 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way | Each | 268.83 | 268.83 | 48.0 | False | None | None | False | None | False | 12903.84 | 0 |
| 3790608 | 143346 | None | code81 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 Way | Each | 328.57 | 328.57 | 21.0 | False | None | None | False | None | False | 6899.97 | 0 |
| 3790609 | 143346 | None | code82 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 16 Way | Each | 373.89 | 373.89 | 10.0 | False | None | None | False | None | False | 3738.9 | 0 |
| 3790610 | 143346 | None | code83 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 18 Way | Each | 417.15 | 417.15 | 8.0 | False | None | None | False | None | False | 3337.2 | 0 |
| 3790611 | 143346 | None | code84 | Supplying and installation of insulated refrigerant copper tubing of 5/8inch and 3/8inch with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. Split | m | 1595.47 | 1595.47 | 3.0 | False | None | None | False | None | False | 4786.41 | 0 |
| 3790612 | 143346 | None | code85 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 4951.21 | 4951.21 | 3.0 | False | None | None | False | None | False | 14853.63 | 0 |
| 3790613 | 143346 | None | code86 | Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 5kVA Capacity | Each | 9955.98 | 9955.98 | 2.0 | False | None | None | False | None | False | 19911.96 | 0 |
| 3790614 | 143346 | None | code87 | Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 100 AH capacity | Each | 12802.9 | 12802.9 | 15.0 | False | None | None | False | None | False | 192043.5 | 0 |
| 3790615 | 143346 | None | code88 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (Sm Enclosure Sheet metal Execution) 125 A | Each | 12693.72 | 12693.72 | 1.0 | False | None | None | False | None | False | 12693.72 | 0 |
| 3790616 | 143346 | None | code89 | Supplying and fixing moulded Case Circuit Breaker (mCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, micro processor release shall have Earth Fault as per IS/IEC 60947-2. (Icu equals 100per lcs). In 4P mCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For microprocessor mCCBS Facility for segregating Priority and Non-Priority loads must be available in the mCCB. mCCB hall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 125 A 25kA | Each | 8855.94 | 8855.94 | 1.0 | False | None | None | False | None | False | 8855.94 | 0 |
| 3790617 | 143346 | None | code90 | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. 63 A | Each | 2381.36 | 2381.36 | 6.0 | False | None | None | False | None | False | 14288.16 | 0 |
| 3790618 | 143346 | None | code91 | Supplying and fixing HRC fuse units base on existing switch / panel board. 32 to 63A | Each | 630.36 | 630.36 | 18.0 | False | None | None | False | None | False | 11346.48 | 0 |
| 3790619 | 143346 | None | code92 | Fixing of A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. 15A to 63 A TPDT/COS | Each | 298.7 | 298.7 | 6.0 | False | None | None | False | None | False | 1792.2 | 0 |
| 3790620 | 143346 | None | code93 | Fixing of A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. 100A to 250A TPDT/COS | Each | 485.13 | 485.13 | 1.0 | False | None | None | False | None | False | 485.13 | 0 |
| 3790621 | 143346 | None | code94 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 100 A | Each | 711.73 | 711.73 | 3.0 | False | None | None | False | None | False | 2135.19 | 0 |
| 3790622 | 143346 | None | code95 | Supplying and fixing regular mCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity mCB's single phase/3 phase/single door with powder coated painting made out of 14 SWG mS enclosure. 1-Single Door 12 Way SP andN | Each | 1918.89 | 1918.89 | 2.0 | False | None | None | False | None | False | 3837.78 | 0 |
| 3790623 | 143346 | None | code96 | Supplying and fixing regular mCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity mCB's single phase/3 phase/single door with powder coated painting made out of 14 SWG mS enclosure. II-Double Door 12 Way SP andN | Each | 2398.87 | 2398.87 | 2.0 | False | None | None | False | None | False | 4797.74 | 0 |
| 3790624 | 143346 | None | code97 | Supplying and fixing miniature circuit breakers on existing mCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 427.45 | 427.45 | 9.0 | False | None | None | False | None | False | 3847.05 | 0 |
| 3790625 | 143346 | None | code98 | Supplying and fixing miniature circuit breakers on existing mCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP | Each | 761.17 | 761.17 | 9.0 | False | None | None | False | None | False | 6850.53 | 0 |
| 3790626 | 143346 | None | code99 | Supplying and fixing miniature circuit breakers on existing mCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3180.64 | 3180.64 | 7.0 | False | None | None | False | None | False | 22264.48 | 0 |
| 3790627 | 143346 | None | code100 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole | Each | 5711.35 | 5711.35 | 2.0 | False | None | None | False | None | False | 11422.7 | 0 |
| 3790628 | 143346 | None | code101 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board | Each | 9532.65 | 9532.65 | 1.0 | False | None | None | False | None | False | 9532.65 | 0 |
| 3790629 | 143346 | None | code102 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9594.45 | 9594.45 | 1.0 | False | None | None | False | None | False | 9594.45 | 0 |
| 3790630 | 143346 | None | code103 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C | Each | 530.45 | 530.45 | 3.0 | False | None | None | False | None | False | 1591.35 | 0 |
| 3790631 | 143346 | None | code104 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 578.86 | 578.86 | 3.0 | False | None | None | False | None | False | 1736.58 | 0 |
| 3790632 | 143346 | None | code105 | Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DmC insulator which are mounted on powder coated 40x6mm m.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 3538.05 | 3538.05 | 1.0 | False | None | None | False | None | False | 3538.05 | 0 |
| 3790633 | 143346 | None | code106 | Supplying and fixing angle iron frame work fabricated out of m.S. angle iron and m.S. Flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm | m | 406.85 | 406.85 | 7.5 | False | None | None | False | None | False | 3051.375 | 0 |
| 3790634 | 143346 | None | code107 | Fabricating supplying and mounting mS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG | Sq CM | 0.44 | 0.44 | 96077.5 | False | None | None | False | None | False | 42274.1 | 0 |
| 3790635 | 143346 | None | code108 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. | Each | 1984.81 | 1984.81 | 1.0 | False | None | None | False | None | False | 1984.81 | 0 |
| 3790636 | 143346 | None | code109 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-6941990. 3C x 2.5 mm2 | m | 120.51 | 120.51 | 180.0 | False | None | None | False | None | False | 21691.8 | 0 |
| 3790637 | 143346 | None | code110 | Rod type of earthing using 40 mm Dia, 3 mtr long mS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal and connected to equipment ground terminal using PVC Al wire as specified | No | 2237.16 | 2237.16 | 9.0 | False | None | None | False | None | False | 20134.44 | 0 |
| 3790638 | 143346 | None | code111 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 379.04 | 379.04 | 16.0 | False | None | None | False | None | False | 6064.64 | 0 |
| 3790639 | 143346 | None | code112 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete minimum Weight of GI Pipe: 7.3 Kg | No | 765.29 | 765.29 | 8.0 | False | None | None | False | None | False | 6122.32 | 0 |
| 3790640 | 143346 | None | code113 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 696.28 | 696.28 | 8.0 | False | None | None | False | None | False | 5570.24 | 0 |
| 3790641 | 143346 | None | code114 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | No | 319.3 | 319.3 | 8.0 | False | None | None | False | None | False | 2554.4 | 0 |
| 3790642 | 143346 | None | code115 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, rmouring strip thickness and resistivity as per IS-3975. 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 384411.45 | 384411.45 | 0.14 | False | None | None | False | None | False | 53817.603 | 0 |
| 3790643 | 143346 | None | code116 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff
a In existing trench/duct. 3x95 to 150 Sqmm
b on wall/ Structure 3x95 to 150 Sqmm | Km | 63161.66 | 63161.66 | 0.14 | False | None | None | False | None | False | 8842.6324 | 0 |
| 3790644 | 143346 | None | code117 | Supplying Galvanized steel flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely - 50 mm | Each | 127.72 | 127.72 | 8.0 | False | None | None | False | None | False | 1021.76 | 0 |
| 3790645 | 143346 | None | code118 | Compression type Aluminium Tubular in Line Connector for Aluminum Conductor. 16 sqmm | Each | 3.09 | 3.09 | 16.0 | False | None | None | False | None | False | 49.44 | 0 |
| 3790646 | 143346 | None | code119 | Heavy Duty Copper Terminal Long Barrel. 50 Sqmm Copper Terminal, Apprx Wt 26 Gm | No | 59.74 | 59.74 | 4.0 | False | None | None | False | None | False | 238.96 | 0 |
| 3790647 | 143346 | None | code120 | Heavy Duty Copper Terminal Long Barrel. 120 Sqmm Copper Terminal, Apprx Wt 64 Gm | No | 144.2 | 144.2 | 12.0 | False | None | None | False | None | False | 1730.4 | 0 |
| 3790648 | 143346 | None | code121 | Providing, Laying and Fixing of GI pipes conforming to IS 1239 1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. For Heavy Duty GI pipe of 100mm dia | m | 1454.36 | 1454.36 | 60.0 | False | None | None | False | None | False | 87261.6 | 0 |