createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723805190171
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd627000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-09-2024 17:30:00
tenderQueryClose05-09-2024 16:30:00
technicalBidOpen09-09-2024 10:30:00
publishedDate21-08-2024 11:39:00
publishedByPostCMC_MCOM_CNP
publishedByUserKPE13996 - MAHENDRA B
bidValidityPeriod90
noOfCalls1
preBidMeetingDate30-08-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonJayanna M R
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9844574499
tenderSupplierListNone
tenderSchedule
createdTs1723805190207
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT25244
titleCONSTRUCTION OF CITY MUNICIPAL COUNCIL OFFICE BUILDING AT CHANNAPATNA CITY LIMITS (PHASE - I)
descriptionCONSTRUCTION OF CITY MUNICIPAL COUNCIL OFFICE BUILDING AT CHANNAPATNA CITY LIMITS (PHASE - I)
categoryWORKS
categoryTextWorks
ecv41776453.27
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2386
locationNameDMA City Municipal Council Channapattna
provisionalAmount49800000.0
groupOverheadTotal0.0
fileNumberCMC/CPT/CR/OFFICEBUILDING/PHASE-1/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17238051900000NoneNoneBuildingsCONSTRUCTION OF CITY MUNICIPAL COUNCIL OFFICE BUILDING AT CHANNAPATNA CITY LIMITS (PHASE - I)41776453.27
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3790528143346Nonecode01Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In all kinds of soils Depth upto 3mCum105.06105.062621.15FalseNoneNoneFalseNoneFalse275378.0190
3790529143346Nonecode02Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In all kinds of soils Depth Depth 3 m to 6 mCum120.51120.51448.18FalseNoneNoneFalseNoneFalse54010.17180
3790530143346Nonecode03Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum373.89373.89640.28FalseNoneNoneFalseNoneFalse239394.28920
3790531143346Nonecode04Compacting original ground supporting embankment : Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OmC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment constructionCum108.15108.15138.31FalseNoneNoneFalseNoneFalse14958.22650
3790532143346Nonecode05Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.981064.0FalseNoneNoneFalseNoneFalse291514.720
3790533143346Nonecode06Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of workCum87.5587.551485.53FalseNoneNoneFalseNoneFalse130058.15150
3790534143346Nonecode07Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20per E.C. / Lindane 20 E.C. 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm121.54121.541096.87FalseNoneNoneFalseNoneFalse133313.57980
3790535143346Nonecode08Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.92226.52FalseNoneNoneFalseNoneFalse1321499.55840
3790536143346Nonecode09Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregatesCum7229.497229.49525.45FalseNoneNoneFalseNoneFalse3798735.52050
3790537143346Nonecode10Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6580.676580.671.52FalseNoneNoneFalseNoneFalse10002.61840
3790538143346Nonecode11Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates. a) Column upto Plinth levelCum11805.2411805.2418.14FalseNoneNoneFalseNoneFalse214147.05360
3790539143346Nonecode12Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates. b) BeamsCum10416.3910416.3963.45FalseNoneNoneFalseNoneFalse660919.94550
3790540143346Nonecode13Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates. a) ColumnCum12269.2612269.26224.55FalseNoneNoneFalseNoneFalse2755062.3330
3790541143346Nonecode14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates. b) BeamsCum11547.5411547.54170.6FalseNoneNoneFalseNoneFalse1970010.3240
3790542143346Nonecode15Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates. c) Slab and RampCum10825.8210825.82384.31FalseNoneNoneFalseNoneFalse4160470.88420
3790543143346Nonecode16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m20 Design mix Using 20 mm nominal size graded crushed coarse aggregatesCum6828.96828.9157.37FalseNoneNoneFalseNoneFalse1074663.9930
3790544143346Nonecode17Supplying, fitting and placing TmT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne92140.7192140.71191.51FalseNoneNoneFalseNoneFalse17645867.37210
3790545143346Nonecode18Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with Cm 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1349.31349.31377.99FalseNoneNoneFalseNoneFalse1859321.9070
3790546143346Nonecode19Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall PlasteringSqm382.13382.131746.88FalseNoneNoneFalseNoneFalse667535.25440
3790547143346Nonecode20Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Internal Wall Plastering)Sqm287.37287.372155.3FalseNoneNoneFalseNoneFalse619368.5610
3790548143346Nonecode21Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Ceiling)Sqm217.33217.331515.05FalseNoneNoneFalseNoneFalse329265.81650
3790549143346Nonecode22Providing mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specificationsCum127928.06127928.061.72FalseNoneNoneFalseNoneFalse220036.26320
3790550143346Nonecode23Providing and fixing in position fully panelled mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7103.917103.9155.2FalseNoneNoneFalseNoneFalse392135.8320
3790551143346Nonecode24Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1046.481046.4823.0FalseNoneNoneFalseNoneFalse24069.040
3790552143346Nonecode25Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)No283.25283.2592.0FalseNoneNoneFalseNoneFalse26059.00
3790553143346Nonecode26Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10mmEach360.5360.569.0FalseNoneNoneFalseNoneFalse24874.50
3790554143346Nonecode27Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. completeNo1083.561083.5623.0FalseNoneNoneFalseNoneFalse24921.880
3790555143346Nonecode28Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mmNo256.47256.4754.0FalseNoneNoneFalseNoneFalse13849.380
3790556143346Nonecode29Providing and fixing m.S. grills of required pattern in frames of windows etc. with m.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Kgs188.49188.492053.8FalseNoneNoneFalseNoneFalse387120.7620
3790557143346Nonecode30Providing and fixing of louvered ventilator made out of multi chambered UPVC(matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made)Sqm5890.575890.5748.3FalseNoneNoneFalseNoneFalse284514.5310
3790558143346Nonecode31Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m30 Design mix Using 20 mm nominal size graded crushed coarse aggregates. d. ChajjaCum10464.9510464.957.52FalseNoneNoneFalseNoneFalse78696.4240
3790559143346Nonecode32Providing and laying cinder concrete in cement 1:15 ( 1 cement 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2077.512077.515.13FalseNoneNoneFalseNoneFalse10657.62630
3790560143346Nonecode33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with Cm 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1137.121137.1241.09FalseNoneNoneFalseNoneFalse46724.26080
3790561143346Nonecode34Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum142216.22142216.220.39FalseNoneNoneFalseNoneFalse55464.32580
3790562143346Nonecode35Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixturesSqm7667.327667.3218.0FalseNoneNoneFalseNoneFalse138011.760
3790563143346Nonecode36Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows and other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with m.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mmm786.92786.9257.0FalseNoneNoneFalseNoneFalse44854.440
3790564143346Nonecode37Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness For ToiletsSqm3589.553589.5515.75FalseNoneNoneFalseNoneFalse56535.41250
3790565143346Nonecode38Providing and fixing of 2.5 track x 2 panel sliding windows made out of multi chambered UPVC(matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made)Sqm6747.536747.5357.0FalseNoneNoneFalseNoneFalse384609.210
3790566143346Nonecode39Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400per and tensile strength greater than 2mPa as per ASTm D412. The waterproofing membrane to be applied in 2coats at 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer at 150 g/m2 and protection with 120 gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making covering at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm841.51841.5149.6FalseNoneNoneFalseNoneFalse41738.8960
3790567143346Nonecode40Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipesm318.27318.2715.0FalseNoneNoneFalseNoneFalse4774.050
3790568143346Nonecode41Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesm390.37390.3780.0FalseNoneNoneFalseNoneFalse31229.60
3790569143346Nonecode42Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipesm491.31491.3140.0FalseNoneNoneFalseNoneFalse19652.40
3790570143346Nonecode43Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipesm573.71573.7112.0FalseNoneNoneFalseNoneFalse6884.520
3790571143346Nonecode44Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 25 mm nominal dia Pipesm304.88304.8845.0FalseNoneNoneFalseNoneFalse13719.60
3790572143346Nonecode45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 32 mm nominal dia Pipesm383.16383.1630.0FalseNoneNoneFalseNoneFalse11494.80
3790573143346Nonecode46Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 40 mm nominal dia Pipesm491.31491.3110.0FalseNoneNoneFalseNoneFalse4913.10
3790574143346Nonecode47Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 50 mm nominal dia Pipesm742.63742.6325.0FalseNoneNoneFalseNoneFalse18565.750
3790575143346Nonecode48Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work. 65 mm nominal dia Pipesm1442.01442.010.0FalseNoneNoneFalseNoneFalse14420.00
3790576143346Nonecode49Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :. 25 mm nominal boreNo565.47565.472.0FalseNoneNoneFalseNoneFalse1130.940
3790577143346Nonecode50Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal boreNo615.94615.943.0FalseNoneNoneFalseNoneFalse1847.820
3790578143346Nonecode51Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal boreNo723.06723.063.0FalseNoneNoneFalseNoneFalse2169.180
3790579143346Nonecode52Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal boreNo880.65880.653.0FalseNoneNoneFalseNoneFalse2641.950
3790580143346Nonecode53Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 65 mm nominal boreNo1453.331453.331.0FalseNoneNoneFalseNoneFalse1453.330
3790581143346Nonecode54Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover.Each5617.625617.627.0FalseNoneNoneFalseNoneFalse39323.340
3790582143346Nonecode55Providing and fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with m.S flats 32x6 mm etc and painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each2020.862020.867.0FalseNoneNoneFalseNoneFalse14146.020
3790583143346Nonecode56Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore VerticalNo952.75952.751.0FalseNoneNoneFalseNoneFalse952.750
3790584143346Nonecode57Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (For 2000 liters capacity)l9.279.272000.0FalseNoneNoneFalseNoneFalse18540.00
3790585143346Nonecode58Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 32mm dia, 10kg/sqcm and class 5m69.0169.0130.0FalseNoneNoneFalseNoneFalse2070.30
3790586143346Nonecode59Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 50mm dia, 6kg/sqcm and class 5m104.03104.0325.0FalseNoneNoneFalseNoneFalse2600.750
3790587143346Nonecode60Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 75mm dia, 6kg/sqcm and class 3m226.6226.675.0FalseNoneNoneFalseNoneFalse16995.00
3790588143346Nonecode61Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 110mm dia, 6kg/sqcm and class 3m423.33423.3350.0FalseNoneNoneFalseNoneFalse21166.50
3790589143346Nonecode62Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 140mm dia, 6kg/sqcm and class 3m601.52601.5240.0FalseNoneNoneFalseNoneFalse24060.80
3790590143346Nonecode63Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails and bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 mCum269.86269.8675.0FalseNoneNoneFalseNoneFalse20239.50
3790591143346Nonecode64Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum164.8164.8125.0FalseNoneNoneFalseNoneFalse20600.00
3790592143346Nonecode65Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. completeEach20716.3920716.391.0FalseNoneNoneFalseNoneFalse20716.390
3790593143346Nonecode66Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thickm67.9867.98700.0FalseNoneNoneFalseNoneFalse47586.00
3790594143346Nonecode67Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thickm80.3480.341000.0FalseNoneNoneFalseNoneFalse80340.00
3790595143346Nonecode68Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5 mm thickm106.09106.09200.0FalseNoneNoneFalseNoneFalse21218.00
3790596143346Nonecode69Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thickm70.0470.04340.0FalseNoneNoneFalseNoneFalse23813.60
3790597143346Nonecode70Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thickm81.3781.37450.0FalseNoneNoneFalseNoneFalse36616.50
3790598143346Nonecode71Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3mtr from tapping point to out let via switch boxPoint277.07277.0718.0FalseNoneNoneFalseNoneFalse4987.260
3790599143346Nonecode72Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. medium point above 3mtr upto 6mtr from tapping point to out let via switch boxPoint390.37390.3745.0FalseNoneNoneFalseNoneFalse17566.650
3790600143346Nonecode73Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6mtr upto 10mtr from tapping point to out let via switch boxPoint571.65571.6596.0FalseNoneNoneFalseNoneFalse54878.40
3790601143346Nonecode74Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switchesPoint697.31697.312.0FalseNoneNoneFalseNoneFalse1394.620
3790602143346Nonecode75Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6mts upto 10mtr from tapping point to out let via switches boxPoint1018.671018.673.0FalseNoneNoneFalseNoneFalse3056.010
3790603143346Nonecode76Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 WayEach142.14142.1455.0FalseNoneNoneFalseNoneFalse7817.70
3790604143346Nonecode77Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 WayEach163.77163.7730.0FalseNoneNoneFalseNoneFalse4913.10
3790605143346Nonecode78Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 WayEach182.31182.3110.0FalseNoneNoneFalseNoneFalse1823.10
3790606143346Nonecode79Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 WayEach226.6226.610.0FalseNoneNoneFalseNoneFalse2266.00
3790607143346Nonecode80Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 WayEach268.83268.8348.0FalseNoneNoneFalseNoneFalse12903.840
3790608143346Nonecode81Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 WayEach328.57328.5721.0FalseNoneNoneFalseNoneFalse6899.970
3790609143346Nonecode82Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 16 WayEach373.89373.8910.0FalseNoneNoneFalseNoneFalse3738.90
3790610143346Nonecode83Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 18 WayEach417.15417.158.0FalseNoneNoneFalseNoneFalse3337.20
3790611143346Nonecode84Supplying and installation of insulated refrigerant copper tubing of 5/8inch and 3/8inch with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. Splitm1595.471595.473.0FalseNoneNoneFalseNoneFalse4786.410
3790612143346Nonecode85Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each4951.214951.213.0FalseNoneNoneFalseNoneFalse14853.630
3790613143346Nonecode86Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 5kVA CapacityEach9955.989955.982.0FalseNoneNoneFalseNoneFalse19911.960
3790614143346Nonecode87Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 100 AH capacityEach12802.912802.915.0FalseNoneNoneFalseNoneFalse192043.50
3790615143346Nonecode88Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (Sm Enclosure Sheet metal Execution) 125 AEach12693.7212693.721.0FalseNoneNoneFalseNoneFalse12693.720
3790616143346Nonecode89Supplying and fixing moulded Case Circuit Breaker (mCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, micro processor release shall have Earth Fault as per IS/IEC 60947-2. (Icu equals 100per lcs). In 4P mCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For microprocessor mCCBS Facility for segregating Priority and Non-Priority loads must be available in the mCCB. mCCB hall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 125 A 25kAEach8855.948855.941.0FalseNoneNoneFalseNoneFalse8855.940
3790617143346Nonecode90Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. 63 AEach2381.362381.366.0FalseNoneNoneFalseNoneFalse14288.160
3790618143346Nonecode91Supplying and fixing HRC fuse units base on existing switch / panel board. 32 to 63AEach630.36630.3618.0FalseNoneNoneFalseNoneFalse11346.480
3790619143346Nonecode92Fixing of A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. 15A to 63 A TPDT/COSEach298.7298.76.0FalseNoneNoneFalseNoneFalse1792.20
3790620143346Nonecode93Fixing of A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. 100A to 250A TPDT/COSEach485.13485.131.0FalseNoneNoneFalseNoneFalse485.130
3790621143346Nonecode94Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 100 AEach711.73711.733.0FalseNoneNoneFalseNoneFalse2135.190
3790622143346Nonecode95Supplying and fixing regular mCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity mCB's single phase/3 phase/single door with powder coated painting made out of 14 SWG mS enclosure. 1-Single Door 12 Way SP andNEach1918.891918.892.0FalseNoneNoneFalseNoneFalse3837.780
3790623143346Nonecode96Supplying and fixing regular mCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity mCB's single phase/3 phase/single door with powder coated painting made out of 14 SWG mS enclosure. II-Double Door 12 Way SP andNEach2398.872398.872.0FalseNoneNoneFalseNoneFalse4797.740
3790624143346Nonecode97Supplying and fixing miniature circuit breakers on existing mCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach427.45427.459.0FalseNoneNoneFalseNoneFalse3847.050
3790625143346Nonecode98Supplying and fixing miniature circuit breakers on existing mCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DPEach761.17761.179.0FalseNoneNoneFalseNoneFalse6850.530
3790626143346Nonecode99Supplying and fixing miniature circuit breakers on existing mCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3180.643180.647.0FalseNoneNoneFalseNoneFalse22264.480
3790627143346Nonecode100Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 poleEach5711.355711.352.0FalseNoneNoneFalseNoneFalse11422.70
3790628143346Nonecode101Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel boardEach9532.659532.651.0FalseNoneNoneFalseNoneFalse9532.650
3790629143346Nonecode102Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach9594.459594.451.0FalseNoneNoneFalseNoneFalse9594.450
3790630143346Nonecode103Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.CEach530.45530.453.0FalseNoneNoneFalseNoneFalse1591.350
3790631143346Nonecode104Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each578.86578.863.0FalseNoneNoneFalseNoneFalse1736.580
3790632143346Nonecode105Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DmC insulator which are mounted on powder coated 40x6mm m.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm3538.053538.051.0FalseNoneNoneFalseNoneFalse3538.050
3790633143346Nonecode106Supplying and fixing angle iron frame work fabricated out of m.S. angle iron and m.S. Flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mmm406.85406.857.5FalseNoneNoneFalseNoneFalse3051.3750
3790634143346Nonecode107Fabricating supplying and mounting mS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWGSq CM0.440.4496077.5FalseNoneNoneFalseNoneFalse42274.10
3790635143346Nonecode108Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.Each1984.811984.811.0FalseNoneNoneFalseNoneFalse1984.810
3790636143346Nonecode109Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-6941990. 3C x 2.5 mm2m120.51120.51180.0FalseNoneNoneFalseNoneFalse21691.80
3790637143346Nonecode110Rod type of earthing using 40 mm Dia, 3 mtr long mS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal and connected to equipment ground terminal using PVC Al wire as specifiedNo2237.162237.169.0FalseNoneNoneFalseNoneFalse20134.440
3790638143346Nonecode111Bentonite clay slurry for earthing in 50 Kg BagBag379.04379.0416.0FalseNoneNoneFalseNoneFalse6064.640
3790639143346Nonecode112GI Grounding pipe, B - Class, 42 mm dia, 2.5 mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete minimum Weight of GI Pipe: 7.3 KgNo765.29765.298.0FalseNoneNoneFalseNoneFalse6122.320
3790640143346Nonecode113Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo696.28696.288.0FalseNoneNoneFalseNoneFalse5570.240
3790641143346Nonecode114Good Quality Salt for grounding purposes packed in 50 Kg gunny bagNo319.3319.38.0FalseNoneNoneFalseNoneFalse2554.40
3790642143346Nonecode1151.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, rmouring strip thickness and resistivity as per IS-3975. 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km384411.45384411.450.14FalseNoneNoneFalseNoneFalse53817.6030
3790643143346Nonecode116Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff a In existing trench/duct. 3x95 to 150 Sqmm b on wall/ Structure 3x95 to 150 SqmmKm63161.6663161.660.14FalseNoneNoneFalseNoneFalse8842.63240
3790644143346Nonecode117Supplying Galvanized steel flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely - 50 mmEach127.72127.728.0FalseNoneNoneFalseNoneFalse1021.760
3790645143346Nonecode118Compression type Aluminium Tubular in Line Connector for Aluminum Conductor. 16 sqmmEach3.093.0916.0FalseNoneNoneFalseNoneFalse49.440
3790646143346Nonecode119Heavy Duty Copper Terminal Long Barrel. 50 Sqmm Copper Terminal, Apprx Wt 26 GmNo59.7459.744.0FalseNoneNoneFalseNoneFalse238.960
3790647143346Nonecode120Heavy Duty Copper Terminal Long Barrel. 120 Sqmm Copper Terminal, Apprx Wt 64 GmNo144.2144.212.0FalseNoneNoneFalseNoneFalse1730.40
3790648143346Nonecode121Providing, Laying and Fixing of GI pipes conforming to IS 1239 1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. For Heavy Duty GI pipe of 100mm diam1454.361454.3660.0FalseNoneNoneFalseNoneFalse87261.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17238051910000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17238051910000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17238051910000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17238051910000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17238051910000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17238930990000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e Procurement portal due to internet connectivity issues and technical glitches at bidder s endNone
17238931370000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17238931530000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17238931780000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17238931940000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17238932100000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27-07-2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fundNone
17238932300000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so everNone
17238932440000NoneNoneELIGIBILITYThe earnest money deposit will be forfeited if the documents submitted by the tenderer found to be misleading/forged or fakeNone
17238932700000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2024-25None
17238932810000NoneNoneELIGIBILITYTurnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsNone
17238932960000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17238933080000NoneNoneELIGIBILITYBidder has to quote rates excluding GST, GST shall be paid separately as per applicableNone
17238933230000NoneNoneELIGIBILITYAll the Work done certificate uploaded should include E-procurement indent numberNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Satisfactory completed, at least one similar Building work not less than Rs.249.00 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Executed in any one year (for a continuous period of 12 months) the following minimum quantities of work Earthwork excavation / Embankment 3028.00 cum Cement Concrete (Plain & Reinforced) 1290 cum Steel reinforcement/ Fabrication / Structural Steel 155 tonne Masonry (BBM/SSM/CC Block) 225 cumPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAvailability by owning at least 50% of the required key and critical equipment for this work and the remaining 50% can be deployed on lease /hire basis for all works provided, the relevant documents (Applicants shall indicate the make, year of manufacture, capacity and working conditions of each of the equipments along with RC issued by R.T.O./Sale deed/purchase invoice, hire/lease agreements) shall be furnished. Equipment Details. Excavator 2 Nos Tipper 4 Nos Self-loading Concrete mixer / Batching plant 2Nos/1NoCapabilities of Vendorkey and critical equipment
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RC issued by R.T.O./Sale deed/purchase invoice, hire/lease agreements
NoneNoneNoneNoneAssessed available tender capacityCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Related certificate
NoneNoneNoneNoneClass-II and Above PWD REGISTRATION CERTIFICATECapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Achieved in at least two financial years a minimum annual financial turnover of Rs. 996.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of no less than Rs.125.00 Lakhs (Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc)Financial StatusLine of credit
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Work Done CertificateTrueTechnical Bid
Line of CreditTrueTechnical Bid
Executed in one year the following minimum quantities of work signed by officer not below the rank of Executive EngineerTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724153189000
version0
createdDateNone
modifiedDateNone
blockNumberCMC OFFICE, CHANNAPATNA
streetNone
cityCHANNAPATNA
stateKarnataka
pin562160
tenderRecallDTONone