1723980659000 | 0 | None | None | Other Works | Construction of Highmast pole and Lights at ward no 4 and 14 in TMC Kurugodu | 1047591.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3802261 | 144291 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m, PWD DSR 2023-24 Volume-I Page No. 6 Item No. 1.14.1 | Cum | 107.1 | 107.1 | 13.58 | False | None | None | False | None | False | 1454.418 | 0 | 3802262 | 144291 | None | 002 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. PWD DSR 2023-24, Volume-I Page No. 15 Item No. 2.1.2 | Cum | 6288.45 | 6288.45 | 0.97 | False | None | None | False | None | False | 6099.7965 | 0 | 3802263 | 144291 | None | 003 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.PWD DSR 2023-24 Volume-I Page No. 9 Item No. 2.2.1 | Cum | 6601.35 | 6601.35 | 10.43 | False | None | None | False | None | False | 68852.0805 | 0 | 3802264 | 144291 | None | 004 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (All other type of structures).PWD DSR 2023-24 Volume-I Page No. 18, Item No. 2.11h | Tonne | 82961.55 | 82961.55 | 0.3042 | False | None | None | False | None | False | 25236.90351 | 0 | 3802265 | 144291 | None | 005 | Form work Foundation upto Plinth(Isolated)(PWD DSR 2023-24 Volume-I Page No. 111 Item No.1(a) 8% OF CONCRETE RATE) | Cum | 528.11 | 528.11 | 10.43 | False | None | None | False | None | False | 5508.1873 | 0 | 3802266 | 144291 | None | 006 | Fabrication,Supplying,Erection,TestingandCommissioningof.mslongPolygonhighmastwithSingle/Multipletelescopicsectionshaving,(minimumoverlapdistanceof1.5timesoftopsection)thicknessasperBSEN10025grades355JO/ASTMA57250steelsheetplateforshaftsuitabletowithstandawindvelocityof47m/sasperIS875part3(asperGADrawing).BaseplateasperIS2062/ASTMA57250.ThemastshallbeGalvanizedinsingleHotdipasperBSENISO1461/ASTMA123withanaverage70micronsasperIS2629,andweldedasperBS5135SingleLSeamjointThemastshallhave2WayheadframewithdiecastLM6pulleys,stainlesssteelaxle,PhosphorusBronzebearingbushpressfittedwithseparateguidesfor2runsof5mmdia,stainlesssteelwireropeofAISI304grade7/19core,(FactorofSafetyasperTRno7).2.5mm2EPRinsulatedPCPsheathedtrailingpowercablehousedinsidethebottomshaftofmastwithdoorhavinglockingarrangementThemastshallhavemanual/powertool(Suitablereversiblegearedmotoroperatingon230/415V,50Hz,shallbeprovideabove15Mtrmast)Themastshallhavelanternof2segments,suitablediawithmaxloadcarryingcapacityasperIS1239.ThemastshallbeerectedonexistingRCCfooting.Themastshallbesuppliedwith3mmthicktemplate,lightningarresterof1.2mlengthgalvanizedpipewithtoparrowfittedontopoftheheadframecoverandGLStypeaviationtwinlAfittingwithwiringcomplete.(excludingfoundation)asper technical data.12 m/12.5 m - Top 100 mm and Bottom 310 mm dia (PWD ELE SR 2023-24 Volume-VI Page No. 13 OF 105, Item No. 4.5.1 | Each | 137550.0 | 137550.0 | 2.0 | False | None | None | False | None | False | 275100.0 | 0 | 3802267 | 144291 | None | 007 | SupplyofLEDfloodlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonate/clearglassmaterial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hrumenMaintenanceof70,CCT5500K,IP66opticalandelectricalcompartmentimpactresistanceofcompleteluminaireIK08.PowerFactor0.9withmains,SurgeProtectionMin5KValongwithOvervoltage/Overload,shortcircuitmisswiringprotection.Compatibleforpolemaulingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V5060Hzapplication.CompliancetoIS10322IEC60598,LM79&LM80AdherencewithRoHS.ULapprovedMCPCB.Topaccessstreetlightwithsinglescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.WSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI75.LuminairemanufacturershouldhaveinhousefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/BodypartWarrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osrammake LED Source.LED Floodlight 200W(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 11.9.6 | No | 19510.05 | 19510.05 | 16.0 | False | None | None | False | None | False | 312160.8 | 0 | 3802268 | 144291 | None | 007 | Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.3x6 Sqm(PWD SR 2023-24 Volume-V Page No. 46 OF 105, Item No. 13.38.1) | Rmtr | 148.94 | 148.94 | 190.0 | False | None | None | False | None | False | 28298.6 | 0 | 3802269 | 144291 | None | 008 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm dia(PWD SR 2023-24 Volume-V Page No.95 , Item No. 9.1.1) | Rmtr | 198.45 | 198.45 | 90.0 | False | None | None | False | None | False | 17860.5 | 0 | 3802270 | 144291 | None | 009 | SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS81301984and(Virgin)PVCinsulationsheathedsuitableforworking voltage upto 1100 Volts as per IS-694:1990,3C x 2.5 mm2(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 2.5.8 | Rmtr | 118.65 | 118.65 | 41.0 | False | None | None | False | None | False | 4864.65 | 0 | 3802271 | 144291 | None | 010 | SupplyingandfixingMicroprocessorbasedElectronic timer(withoutcontactor,DinMountingusingnecessarybolts,nutsandwashersetc.,.)3-120sec setting.(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 5.47) | No | 2430.75 | 2430.75 | 3.0 | False | None | None | False | None | False | 7292.25 | 0 | 3802272 | 144291 | None | 011 | Earthing: Providing and fixing and wiring earth electrode for grounding
circuits IC cutouts and other equipments on the meter board in the pit.
The pits should be filled up with equal proportion of salt and charcoal
150mm around the pipe to complete depth. The connection from the
pipe to the conduits etc. is to established through GI wire of sizes as per
clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts,
the pipe shall have 16 through holes of 12mm dia.(PWD SR 2023-24 Volume-V Page No.157 , Item No. 13.39) | Each | 3937.5 | 3937.5 | 3.0 | False | None | None | False | None | False | 11812.5 | 0 | 3802273 | 144291 | None | 012 | FabricatingsupplyingandmountingMSboxmadeout.SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete.14 SWG(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 5.42.1) | Sq CM | 0.53 | 0.53 | 19000.0 | False | None | None | False | None | False | 10070.0 | 0 | 3802274 | 144291 | None | 013 | SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm.(PWD ELE SR 2023-24 Volume-VI Page No. 20 OF 105, Item No. 5.41.2) | No | 414.75 | 414.75 | 36.0 | False | None | None | False | None | False | 14931.0 | 0 | 3802275 | 144291 | None | 015 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.95/40(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.5.18.2) | No | 832.65 | 832.65 | 3.0 | False | None | None | False | None | False | 2497.95 | 0 | 3802276 | 144291 | None | 016 | Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers. 320 A Page No. 10 Item No.5.7.6 Electrical SR 2021-22 | Each | 1934.1 | 1934.1 | 3.0 | False | None | None | False | None | False | 5802.3 | 0 | 3802277 | 144291 | None | 017 | GESCOM Deposit and Service Charegs for Power Connection | Each | 10000.0 | 10000.0 | 2.0 | False | None | None | False | None | False | 20000.0 | 0 | 3802278 | 144291 | None | 018 | Fabrication,Supplying,Erection,TestingandCommissioningof.mslongPolygonhighmastwithSingle/Multipletelescopicsectionshavingminimumoverlapdistanceof1.5timesoftopsection)thicknessasperBSEN10025grades355JOASTMA57250steelsheetplateforshaftsuitabletowithstandawindvelocityof47msasperIS875part3asperGADrawing.BaseplateasperIS2062ASTMA57250.ThemastshallbeGalvanizedinsingleHotdipasperBSENISO1461ASTMA123withanaverage70micronsasperIS2629,andweldedasperBS5135SingleLSeamjointThemastshallhave2WayheadframewithdiecastLM6pulleys,stainlesssteelaxle,PhosphorusBronzebearingbushpressfittedwithseparateguidesfor2runsof5mmdia,stainlesssteelwireropeofAISI304grade719coreFactorofSafetyasperTRno7.2.5mm2EPRinsulatedPCPsheathedtrailingpowercablehousedinsidethebottomshaftofmastwithdoorhavinglockingarrangementThemastshallhavemanualpowertoolSuitablereversiblegearedmotoroperatingon230415V,50Hz,shallbeprovideabove15MtrmastThemastshallhavelanternof2segments,suitablediawithmaxloadcarryingcapacityasperIS1239.ThemastshallbeerectedonexistingRCCfooting.Themastshallbesuppliedwith3mmthicktemplate,lightningarresterof1.2mlengthgalvanizedpipewithtoparrowfittedontopoftheheadframecoverandGLStypeaviationtwinlAfittingwithwiringcomplete.excludingfoundationasper technical data.16 m Top 150 mm and Bottom 410 mm dia(PWD ELE SR 2023-24 Volume-VI Page No. 13 OF 105, Item No. 4.5.2 | Each | 204750.0 | 204750.0 | 1.0 | False | None | None | False | None | False | 204750.0 | 0 | 3802279 | 144291 | None | 019 | GESCOM Deposit and Service Charegs for Power Connection | Each | 25000.0 | 25000.0 | 1.0 | False | None | None | False | None | False | 25000.0 | 0 |
|