createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724048256471
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1025000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-09-2024 16:00:00
tenderQueryClose02-09-2024 16:00:00
technicalBidOpen21-09-2024 16:00:00
publishedDate20-08-2024 19:05:30
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate03-09-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1724048256495
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT266
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Aland, Aland Taluk, Kalaburagi District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Aland, Aland Taluk, Kalaburagi District
categoryWORKS
categoryTextWorks
ecv68256861.99
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount68256862.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/319/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17240482560000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Aland, Aland Taluk, Kalaburagi District68256861.99
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3806359144524Nonecode01JUNGLE CLEARANCE Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of light jungle SR 2023-24 Page No. 9,Sl. No.2.5 A. VOL-3 ii a Rate per 100SqmSqm412.65412.657.02FalseNoneNoneFalseNoneFalse2896.8030
3806360144524Nonecode02Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Page No. 5,Sl. No.1.1 . VOL-1Sqm95.5595.55702.0FalseNoneNoneFalseNoneFalse67076.10
3806361144524Nonecode03EARTH WORK FOR BUILDING Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m SR 2023-24 Page No. 8,Sl. No.1.14.1 A. VOL-1Cum107.1107.11042.07FalseNoneNoneFalseNoneFalse111605.6970
3806362144524Nonecode04Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In ordinary/soft rock without blasting SR 2023-24 (P.No.8, Vol-1, SI.No.1.15.1 ) soft rock without blasting 20%Cum381.15381.15265.1043FalseNoneNoneFalseNoneFalse101044.5039450
3806363144524Nonecode05CC 1:3:6 For Bed ConcreteProviding and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarseaggregates SR 2023-24 Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4582.62FalseNoneNoneFalseNoneFalse519551.7390
3806364144524Nonecode06ANTI TERMITE TREATMENT Providing and injecting chemical emulsion for Preconstructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications Sl.No 4.1/ Page No. 5- VOL-2Sqm123.9123.9525.0FalseNoneNoneFalseNoneFalse65047.50
3806365144524Nonecode07RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1Cum7185.027185.02404.68FalseNoneNoneFalseNoneFalse2907633.89360
3806366144524Nonecode08RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1 PEDESTALCum7318.087318.0812.42FalseNoneNoneFalseNoneFalse90890.55360
3806367144524Nonecode09RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I upto plinthCum12214.7612214.7619.8FalseNoneNoneFalseNoneFalse241852.2480
3806368144524Nonecode10RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum12214.7612214.7625.92FalseNoneNoneFalseNoneFalse316606.57920
3806369144524Nonecode11RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum12336.912336.925.92FalseNoneNoneFalseNoneFalse319772.4480
3806370144524Nonecode12RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum12460.2712460.2725.92FalseNoneNoneFalseNoneFalse322970.19840
3806371144524Nonecode13RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum12584.8712584.8725.92FalseNoneNoneFalseNoneFalse326199.83040
3806372144524Nonecode14RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum12710.7212710.7225.92FalseNoneNoneFalseNoneFalse329461.86240
3806373144524Nonecode15RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12837.8312837.831.73FalseNoneNoneFalseNoneFalse22209.44590
3806374144524Nonecode16RCC COLUMN(DUMMY COLUMNS) Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 ) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Page 15, Sl. No.2.1.4, Volume-ICum11097.3511097.356.48FalseNoneNoneFalseNoneFalse71910.8280
3806375144524Nonecode17PCC M15 FOR DPC Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Page 15, Sl. No.2.1.4, Volume-ICum6527.856527.851.54FalseNoneNoneFalseNoneFalse10052.8890
3806376144524Nonecode18EARTH REFILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.3783.06FalseNoneNoneFalseNoneFalse218708.6580
3806377144524Nonecode19EARTH FILLING UPTO FLOORING PCC Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.3519.52FalseNoneNoneFalseNoneFalse145101.9360
3806378144524Nonecode20Balance Soil have to brought from Outside Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SL.No 1.8, Page No.7 Volume-ICum497.7497.7344.03FalseNoneNoneFalseNoneFalse171223.7310
3806379144524Nonecode21Flooring Bed Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4543.51FalseNoneNoneFalseNoneFalse273610.45950
3806380144524Nonecode22RCC M25 FOR PLINTH BEAM Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.---- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.4.3 Page No.17 VOL-1Cum9979.29979.276.05FalseNoneNoneFalseNoneFalse758918.160
3806381144524Nonecode23CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II GROUND FLOORSqm1375.51375.5292.77FalseNoneNoneFalseNoneFalse402705.1350
3806382144524Nonecode24CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FIRST FLOORSqm1389.261389.26264.95FalseNoneNoneFalseNoneFalse368084.4370
3806383144524Nonecode25CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II SECOND FLOORSqm1403.151403.15264.95FalseNoneNoneFalseNoneFalse371764.59250
3806384144524Nonecode26CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II THIRD FLOORSqm1417.181417.18264.95FalseNoneNoneFalseNoneFalse375481.8410
3806385144524Nonecode27CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FOURTH FLOORSqm1431.351431.35264.95FalseNoneNoneFalseNoneFalse379236.18250
3806386144524Nonecode28CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II GROUND FLOORSqm1292.551292.55308.34FalseNoneNoneFalseNoneFalse398544.8670
3806387144524Nonecode29CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FIRST FLOORSqm1305.481305.48486.89FalseNoneNoneFalseNoneFalse635625.15720
3806388144524Nonecode30CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II SECOND FLOORSqm1318.531318.53486.89FalseNoneNoneFalseNoneFalse641979.07170
3806389144524Nonecode31CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II THIRD FLOORSqm1331.721331.72486.89FalseNoneNoneFalseNoneFalse648401.15080
3806390144524Nonecode32CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FOURTH FLOORSqm1345.031345.03486.89FalseNoneNoneFalseNoneFalse654881.65670
3806391144524Nonecode33CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II HEAD ROOM DOORSqm1358.481358.48159.94FalseNoneNoneFalseNoneFalse217275.29120
3806392144524Nonecode34CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II GROUND FLOORSqm1159.21159.248.62FalseNoneNoneFalseNoneFalse56360.3040
3806393144524Nonecode35CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FIRST FLOORSqm1170.791170.7997.23FalseNoneNoneFalseNoneFalse113835.91170
3806394144524Nonecode36CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II SECOND FLOORSqm1182.51182.597.23FalseNoneNoneFalseNoneFalse114974.4750
3806395144524Nonecode37CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II THIRD FLOORSqm1194.321194.3297.23FalseNoneNoneFalseNoneFalse116123.73360
3806396144524Nonecode38CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FOURTH FLOORSqm1206.271206.2797.23FalseNoneNoneFalseNoneFalse117285.63210
3806397144524Nonecode39RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.247.73FalseNoneNoneFalseNoneFalse88865.93520
3806398144524Nonecode40RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.211.08FalseNoneNoneFalseNoneFalse128652.0960
3806399144524Nonecode41RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3111.08FalseNoneNoneFalseNoneFalse129938.59480
3806400144524Nonecode42RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5911.08FalseNoneNoneFalseNoneFalse131238.05720
3806401144524Nonecode43RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0311.08FalseNoneNoneFalseNoneFalse132550.37240
3806402144524Nonecode44RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOM DOORCum12082.6612082.660.98FalseNoneNoneFalseNoneFalse11841.00680
3806403144524Nonecode45CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I GROUND FLOORCum9465.389465.383.75FalseNoneNoneFalseNoneFalse35495.1750
3806404144524Nonecode46CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FIRST FLOORCum9560.049560.045.82FalseNoneNoneFalseNoneFalse55639.43280
3806405144524Nonecode47CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I SECOND FLOORCum9655.649655.645.82FalseNoneNoneFalseNoneFalse56195.82480
3806406144524Nonecode48CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I THIRD FLOORCum9752.199752.195.82FalseNoneNoneFalseNoneFalse56757.74580
3806407144524Nonecode49CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FOURTH FLOORCum9849.719849.715.82FalseNoneNoneFalseNoneFalse57325.31220
3806408144524Nonecode50CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I HEAD ROOM DOORCum9948.219948.210.49FalseNoneNoneFalseNoneFalse4874.62290
3806409144524Nonecode51RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.2441.57FalseNoneNoneFalseNoneFalse477898.69680
3806410144524Nonecode52RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.248.13FalseNoneNoneFalseNoneFalse558847.0560
3806411144524Nonecode53RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3148.13FalseNoneNoneFalseNoneFalse564435.43030
3806412144524Nonecode54RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5948.13FalseNoneNoneFalseNoneFalse570080.11670
3806413144524Nonecode55RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0348.13FalseNoneNoneFalseNoneFalse575780.63390
3806414144524Nonecode56RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12082.6612082.662.32FalseNoneNoneFalseNoneFalse28031.77120
3806415144524Nonecode57RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I Ground floorCum10777.7310777.7380.25FalseNoneNoneFalseNoneFalse864912.83250
3806416144524Nonecode58RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.578.0FalseNoneNoneFalseNoneFalse849069.00
3806417144524Nonecode59RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.3678.0FalseNoneNoneFalseNoneFalse857560.080
3806418144524Nonecode60RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.378.0FalseNoneNoneFalseNoneFalse866135.40
3806419144524Nonecode61RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.3478.0FalseNoneNoneFalseNoneFalse874796.520
3806420144524Nonecode62RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.59.9FalseNoneNoneFalseNoneFalse112142.250
3806421144524Nonecode63RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum10777.7310777.734.16FalseNoneNoneFalseNoneFalse44835.35680
3806422144524Nonecode64RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.54.16FalseNoneNoneFalseNoneFalse45283.680
3806423144524Nonecode65RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.364.16FalseNoneNoneFalseNoneFalse45736.53760
3806424144524Nonecode66RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.34.16FalseNoneNoneFalseNoneFalse46193.8880
3806425144524Nonecode67RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.344.16FalseNoneNoneFalseNoneFalse46655.81440
3806426144524Nonecode68RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.54.16FalseNoneNoneFalseNoneFalse47122.40
3806427144524Nonecode69TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I GROUND FLOORTonne93929.8593929.8557.29FalseNoneNoneFalseNoneFalse5381241.10650
3806428144524Nonecode70TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FIRST FLOORTonne94869.1594869.1523.78FalseNoneNoneFalseNoneFalse2255988.3870
3806429144524Nonecode71TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I SECOND FLOORTonne95817.8495817.8423.78FalseNoneNoneFalseNoneFalse2278548.23520
3806430144524Nonecode72TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I THIRD FLOORTonne96776.0296776.0223.78FalseNoneNoneFalseNoneFalse2301333.75560
3806431144524Nonecode73TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FOURTH FLOORTonne97743.7897743.7823.78FalseNoneNoneFalseNoneFalse2324347.08840
3806432144524Nonecode74TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I HEAD ROOMTonne98721.2298721.221.23FalseNoneNoneFalseNoneFalse121427.10060
3806433144524Nonecode75FRAME FOR MAIN DOOR Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.section Sl. No. 12.13.2 Page No. 100, Volume-IIm104580.0104580.00.46FalseNoneNoneFalseNoneFalse48106.80
3806434144524Nonecode76SHUTTER FOR MAIN DOOR Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sl. No. 12.18. Page No. 100, Volume-IISqm6904.86904.811.28FalseNoneNoneFalseNoneFalse77886.1440
3806435144524Nonecode77WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II GROUND FLOORm737.1737.160.0FalseNoneNoneFalseNoneFalse44226.00
3806436144524Nonecode78WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FIRST FLOORm744.47744.4790.0FalseNoneNoneFalseNoneFalse67002.30
3806437144524Nonecode79WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II SECOND FLOORm751.92751.9290.0FalseNoneNoneFalseNoneFalse67672.80
3806438144524Nonecode80WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II THIRD FLOORm759.43759.4390.0FalseNoneNoneFalseNoneFalse68348.70
3806439144524Nonecode81WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FOURTH FLOORm767.03767.0390.0FalseNoneNoneFalseNoneFalse69032.70
3806440144524Nonecode82WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II HEAD ROOMm767.03767.036.0FalseNoneNoneFalseNoneFalse4602.180
3806441144524Nonecode83WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II GROUND FLOORSqm4631.554631.5521.96FalseNoneNoneFalseNoneFalse101708.8380
3806442144524Nonecode84WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FIRST FLOORSqm4677.874677.8728.35FalseNoneNoneFalseNoneFalse132617.61450
3806443144524Nonecode85WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II SECOND FLOORSqm4724.644724.6428.35FalseNoneNoneFalseNoneFalse133943.5440
3806444144524Nonecode86WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II THIRD FLOORSqm4771.894771.8928.35FalseNoneNoneFalseNoneFalse135283.08150
3806445144524Nonecode87WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FOURTH FLOORSqm4819.614819.6128.35FalseNoneNoneFalseNoneFalse136635.94350
3806446144524Nonecode88WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II HEAD ROOMSqm4867.814867.811.89FalseNoneNoneFalseNoneFalse9200.16090
3806447144524Nonecode89UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II Ground floorm246.17246.1762.7FalseNoneNoneFalseNoneFalse15434.8590
3806448144524Nonecode90UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II First Floorm248.63248.63125.4FalseNoneNoneFalseNoneFalse31178.2020
3806449144524Nonecode91UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II SECOND FLOORm251.12251.12125.4FalseNoneNoneFalseNoneFalse31490.4480
3806450144524Nonecode92UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance +/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II THIRD FLOORm253.63253.63125.4FalseNoneNoneFalseNoneFalse31805.2020
3806451144524Nonecode93UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/-0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II FOURTH FLOORm256.17256.17125.4FalseNoneNoneFalseNoneFalse32123.7180
3806452144524Nonecode94UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II Ground floorSqm6432.356432.3517.33FalseNoneNoneFalseNoneFalse111472.62550
3806453144524Nonecode95UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FIRST FLOORSqm6496.676496.6734.65FalseNoneNoneFalseNoneFalse225109.61550
3806454144524Nonecode96UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II SECOND FLOORSqm6561.646561.6434.65FalseNoneNoneFalseNoneFalse227360.8260
3806455144524Nonecode97UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II THIRD FLOORSqm6627.266627.2634.65FalseNoneNoneFalseNoneFalse229634.5590
3806456144524Nonecode98UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FOURTH FLOORSqm6693.536693.5334.65FalseNoneNoneFalseNoneFalse231930.81450
3806457144524Nonecode99HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm GROUND FloorNo566.5566.510.0FalseNoneNoneFalseNoneFalse5665.00
3806458144524Nonecode100HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm First FloorNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3806459144524Nonecode101HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm SECOND FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3806460144524Nonecode102HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm THIRD FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3806461144524Nonecode103HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm FOURTH FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3806462144524Nonecode104HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II GROUND FloorNo386.25386.2518.0FalseNoneNoneFalseNoneFalse6952.50
3806463144524Nonecode105HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II First FloorNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3806464144524Nonecode106HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II SECOND FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3806465144524Nonecode107HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II THIRD FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3806466144524Nonecode108HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II FOURTH FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3806467144524Nonecode109HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II GROUND FloorNo206.0206.018.0FalseNoneNoneFalseNoneFalse3708.00
3806468144524Nonecode110HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II First FloorNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3806469144524Nonecode111HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II SECOND FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3806470144524Nonecode112HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II THIRD FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3806471144524Nonecode113HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II FOURTH FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3806472144524Nonecode114HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II GROUND FloorNo72.172.118.0FalseNoneNoneFalseNoneFalse1297.80
3806473144524Nonecode115HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II First FloorNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3806474144524Nonecode116HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II SECOND FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3806475144524Nonecode117HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II THIRD FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3806476144524Nonecode118HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II FOURTH FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3806477144524Nonecode119HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II GROUND FloorNo103.0103.09.0FalseNoneNoneFalseNoneFalse927.00
3806478144524Nonecode120HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II First FloorNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3806479144524Nonecode121HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II SECOND FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3806480144524Nonecode122HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II THIRD FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3806481144524Nonecode123HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II FOURTH FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3806482144524Nonecode124UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II GROUND FLOORSqm6004.956004.954.32FalseNoneNoneFalseNoneFalse25941.3840
3806483144524Nonecode125UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FIRST FLOORSqm6064.86064.88.28FalseNoneNoneFalseNoneFalse50216.5440
3806484144524Nonecode126UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II SECOND FLOORSqm6125.456125.458.28FalseNoneNoneFalseNoneFalse50718.7260
3806485144524Nonecode127UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II THIRD FLOORSqm6186.76186.78.28FalseNoneNoneFalseNoneFalse51225.8760
3806486144524Nonecode128UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FOURTH FLOORSqm6248.576248.578.28FalseNoneNoneFalseNoneFalse51738.15960
3806487144524Nonecode129GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II GROUND FLOORKg176.4176.41147.2FalseNoneNoneFalseNoneFalse202366.080
3806488144524Nonecode130GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FIRST FLOORKg178.16178.161096.2FalseNoneNoneFalseNoneFalse195298.9920
3806489144524Nonecode131GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II SECOND FLOORKg179.95179.951096.2FalseNoneNoneFalseNoneFalse197261.190
3806490144524Nonecode132GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II THIRD FLOORKg181.75181.751096.2FalseNoneNoneFalseNoneFalse199234.350
3806491144524Nonecode133GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FOURTH FLOORKg183.56183.561096.2FalseNoneNoneFalseNoneFalse201218.4720
3806492144524Nonecode134UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II GROUND FLOORSqm7070.77070.754.36FalseNoneNoneFalseNoneFalse384363.2520
3806493144524Nonecode135UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FIRST FLOORSqm7141.417141.4148.6FalseNoneNoneFalseNoneFalse347072.5260
3806494144524Nonecode136UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II SECOND FLOORSqm7212.827212.8248.6FalseNoneNoneFalseNoneFalse350543.0520
3806495144524Nonecode137UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II THIRD FLOORSqm7284.957284.9548.6FalseNoneNoneFalseNoneFalse354048.570
3806496144524Nonecode138UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FOURTH FLOORSqm7357.87357.848.6FalseNoneNoneFalseNoneFalse357589.080
3806497144524Nonecode139UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II HEAD ROOMSqm7431.387431.382.7FalseNoneNoneFalseNoneFalse20064.7260
3806498144524Nonecode140PUTTY ITEM Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ceiling Sl.No 8.51 Page No.50 Volume-IISqm105.0105.02229.18FalseNoneNoneFalseNoneFalse234063.90
3806499144524Nonecode141INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II GROUND FLOORSqm384.3384.3986.25FalseNoneNoneFalseNoneFalse379015.8750
3806500144524Nonecode142INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FIRST FLOORSqm388.5388.51337.84FalseNoneNoneFalseNoneFalse519750.840
3806501144524Nonecode143INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II SECOND FLOORSqm392.39392.391337.84FalseNoneNoneFalseNoneFalse524955.03760
3806502144524Nonecode144INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II THIRD FLOORSqm396.31396.311337.84FalseNoneNoneFalseNoneFalse530199.37040
3806503144524Nonecode145INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FOURTH FLOORSqm400.27400.271337.84FalseNoneNoneFalseNoneFalse535497.21680
3806504144524Nonecode146INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II HEAD ROOMSqm404.27404.27155.51FalseNoneNoneFalseNoneFalse62868.02770
3806505144524Nonecode147WALL PUTTY FOR ABOVE Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51 Page No.50 Volume-IISqm105.0105.06493.13FalseNoneNoneFalseNoneFalse681778.650
3806506144524Nonecode148ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II GROUND FLOORSqm309.75309.75196.72FalseNoneNoneFalseNoneFalse60934.020
3806507144524Nonecode149ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FIRST FLOORSqm312.85312.85289.96FalseNoneNoneFalseNoneFalse90713.9860
3806508144524Nonecode150ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II SECOND FLOORSqm315.98315.98289.96FalseNoneNoneFalseNoneFalse91621.56080
3806509144524Nonecode151ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II THIRD FLOORSqm319.14319.14289.96FalseNoneNoneFalseNoneFalse92537.83440
3806510144524Nonecode152ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FOURTH FLOORSqm322.33322.33289.96FalseNoneNoneFalseNoneFalse93462.80680
3806511144524Nonecode153EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II GROUND FLOORSqm404.25404.25428.4FalseNoneNoneFalseNoneFalse173180.70
3806512144524Nonecode154EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FIRST FLOORSqm408.45408.45428.4FalseNoneNoneFalseNoneFalse174979.980
3806513144524Nonecode155EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II SECOND FLOORSqm412.53412.53428.4FalseNoneNoneFalseNoneFalse176727.8520
3806514144524Nonecode156EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II THIRD FLOORSqm416.66416.66428.4FalseNoneNoneFalseNoneFalse178497.1440
3806515144524Nonecode157EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FOURTH FLOORSqm420.83420.83428.4FalseNoneNoneFalseNoneFalse180283.5720
3806516144524Nonecode158EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II HEAD ROOMSqm425.03425.03167.63FalseNoneNoneFalseNoneFalse71247.77890
3806517144524Nonecode159FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II GROUND FLOORSqm1319.851319.85160.92FalseNoneNoneFalseNoneFalse212390.2620
3806518144524Nonecode160FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FIRST FLOORSqm1333.051333.05301.47FalseNoneNoneFalseNoneFalse401874.58350
3806519144524Nonecode161FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II SECOND FLOORSqm1346.381346.38301.47FalseNoneNoneFalseNoneFalse405893.17860
3806520144524Nonecode162FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II THIRD FLOORSqm1359.841359.84301.47FalseNoneNoneFalseNoneFalse409950.96480
3806521144524Nonecode163FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FOURTH FLOORSqm1373.41373.4301.47FalseNoneNoneFalseNoneFalse414038.8980
3806522144524Nonecode164GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II GROUND FLOORSqm2994.62994.6317.53FalseNoneNoneFalseNoneFalse950875.3380
3806523144524Nonecode165GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FIRST FLOORSqm3024.553024.5594.2FalseNoneNoneFalseNoneFalse284912.610
3806524144524Nonecode166GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II SECOND FLOORSqm3054.793054.7994.2FalseNoneNoneFalseNoneFalse287761.2180
3806525144524Nonecode167GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II THIRD FLOORSqm3085.343085.3494.2FalseNoneNoneFalseNoneFalse290639.0280
3806526144524Nonecode168GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FOURTH FLOORSqm3116.193116.1994.2FalseNoneNoneFalseNoneFalse293545.0980
3806527144524Nonecode169GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II GROUND FLOORSqm5594.45594.421.34FalseNoneNoneFalseNoneFalse119384.4960
3806528144524Nonecode170GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FIRST FLOORSqm5650.345650.3421.34FalseNoneNoneFalseNoneFalse120578.25560
3806529144524Nonecode171GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II SECOND FLOORSqm5706.855706.8521.34FalseNoneNoneFalseNoneFalse121784.1790
3806530144524Nonecode172GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II THIRD FLOORSqm5763.925763.9221.34FalseNoneNoneFalseNoneFalse123002.05280
3806531144524Nonecode173GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FOURTH FLOORSqm5821.565821.5621.34FalseNoneNoneFalseNoneFalse124232.09040
3806532144524Nonecode174HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi GROUND FLOORm180.0180.046.4FalseNoneNoneFalseNoneFalse8352.00
3806533144524Nonecode175HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FIRST FLOORm181.8181.833.6FalseNoneNoneFalseNoneFalse6108.480
3806534144524Nonecode176HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi SECOND FLOORm183.62183.6233.6FalseNoneNoneFalseNoneFalse6169.6320
3806535144524Nonecode177HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi THIRD FLOORm185.45185.4533.6FalseNoneNoneFalseNoneFalse6231.120
3806536144524Nonecode178HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FOURTH FLOORm187.31187.3133.6FalseNoneNoneFalseNoneFalse6293.6160
3806537144524Nonecode179CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II GROUND FLOORSqm933.45933.4548.0FalseNoneNoneFalseNoneFalse44805.60
3806538144524Nonecode180CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FIRST FLOORSqm942.78942.7874.0FalseNoneNoneFalseNoneFalse69765.720
3806539144524Nonecode181CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II SECOND FLOORSqm952.21952.2174.0FalseNoneNoneFalseNoneFalse70463.540
3806540144524Nonecode182CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II THIRD FLOORSqm961.73961.7374.0FalseNoneNoneFalseNoneFalse71168.020
3806541144524Nonecode183CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FOURTH FLOORSqm971.35971.3574.0FalseNoneNoneFalseNoneFalse71879.90
3806542144524Nonecode184CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II GROUND FLOORSqm1161.31161.3192.78FalseNoneNoneFalseNoneFalse223875.4140
3806543144524Nonecode185CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FIRST FLOORSqm1172.911172.91289.96FalseNoneNoneFalseNoneFalse340096.98360
3806544144524Nonecode186CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II SECOND FLOORSqm1184.641184.64289.96FalseNoneNoneFalseNoneFalse343498.21440
3806545144524Nonecode187CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II THIRD FLOORSqm1196.491196.49289.96FalseNoneNoneFalseNoneFalse346934.24040
3806546144524Nonecode188CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FOURTH FLOORSqm1208.451208.45289.96FalseNoneNoneFalseNoneFalse350402.1620
3806547144524Nonecode189PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR WallsSqm165.9165.9986.25FalseNoneNoneFalseNoneFalse163618.8750
3806548144524Nonecode190PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR CelingSqm165.9165.9434.98FalseNoneNoneFalseNoneFalse72163.1820
3806549144524Nonecode191PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR WallsSqm167.56167.561337.84FalseNoneNoneFalseNoneFalse224168.47040
3806550144524Nonecode192PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR CelingSqm167.56167.56444.8FalseNoneNoneFalseNoneFalse74530.6880
3806551144524Nonecode193PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR WallsSqm169.23169.231337.84FalseNoneNoneFalseNoneFalse226402.66320
3806552144524Nonecode194PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR CelingSqm169.23169.23444.8FalseNoneNoneFalseNoneFalse75273.5040
3806553144524Nonecode195PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR WallsSqm170.93170.931337.84FalseNoneNoneFalseNoneFalse228676.99120
3806554144524Nonecode196PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR CelingSqm170.93170.93444.8FalseNoneNoneFalseNoneFalse76029.6640
3806555144524Nonecode197PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FOURTH FLOOR WallsSqm172.64172.64155.51FalseNoneNoneFalseNoneFalse26847.24640
3806556144524Nonecode198PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM WallsSqm174.36174.36155.51FalseNoneNoneFalseNoneFalse27114.72360
3806557144524Nonecode199PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM CelingSqm174.36174.3615.0FalseNoneNoneFalseNoneFalse2615.40
3806558144524Nonecode200PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Ground floorSqm182.7182.7364.14FalseNoneNoneFalseNoneFalse66528.3780
3806559144524Nonecode201PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II First floorSqm184.53184.53364.14FalseNoneNoneFalseNoneFalse67194.75420
3806560144524Nonecode202PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Second floorSqm186.37186.37364.14FalseNoneNoneFalseNoneFalse67864.77180
3806561144524Nonecode203PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Third floorSqm188.24188.24364.14FalseNoneNoneFalseNoneFalse68545.71360
3806562144524Nonecode204PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II TFourth floorSqm190.12190.12364.14FalseNoneNoneFalseNoneFalse69230.29680
3806563144524Nonecode205PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II HEAD ROOMSqm192.02192.02142.49FalseNoneNoneFalseNoneFalse27360.92980
3806564144524Nonecode206PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Ground floorSqm297.15297.1564.26FalseNoneNoneFalseNoneFalse19094.8590
3806565144524Nonecode207PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II First floorSqm300.12300.1264.26FalseNoneNoneFalseNoneFalse19285.71120
3806566144524Nonecode208PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Second floorSqm303.12303.1264.26FalseNoneNoneFalseNoneFalse19478.49120
3806567144524Nonecode209PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Third floorSqm306.15306.1564.26FalseNoneNoneFalseNoneFalse19673.1990
3806568144524Nonecode210PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II foruth floorSqm309.22309.2264.26FalseNoneNoneFalseNoneFalse19870.47720
3806569144524Nonecode211PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II HEAD ROOMSqm312.31312.3125.14FalseNoneNoneFalseNoneFalse7851.47340
3806570144524Nonecode212SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II GROUND FLOORKg593.25593.25252.0FalseNoneNoneFalseNoneFalse149499.00
3806571144524Nonecode213SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FIRST FLOORKg599.18599.18244.8FalseNoneNoneFalseNoneFalse146679.2640
3806572144524Nonecode214SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II SECOND FLOORKg605.17605.17244.8FalseNoneNoneFalseNoneFalse148145.6160
3806573144524Nonecode215SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II THIRD FLOORKg611.23611.23244.8FalseNoneNoneFalseNoneFalse149629.1040
3806574144524Nonecode216SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FOURTH FLOORKg617.34617.34244.8FalseNoneNoneFalseNoneFalse151124.8320
3806575144524Nonecode217WATER PROOFING Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sl.No 15.1, Page No.149 Volume-IISqm857.85857.85500.0FalseNoneNoneFalseNoneFalse428925.00
3806576144524Nonecode218CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FIRST FLOORSqm2138.852138.8514.6FalseNoneNoneFalseNoneFalse31227.210
3806577144524Nonecode219CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II SECOND FLOORSqm2160.242160.2414.6FalseNoneNoneFalseNoneFalse31539.5040
3806578144524Nonecode220CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II THIRD FLOORSqm2181.842181.8414.6FalseNoneNoneFalseNoneFalse31854.8640
3806579144524Nonecode221CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FOURTH FLOORSqm2203.662203.6614.6FalseNoneNoneFalseNoneFalse32173.4360
3806580144524Nonecode222FLAGGING CONCRETE Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Sl.No 2.1.5, Page No.15 Volume-ICum6156.06156.010.71FalseNoneNoneFalseNoneFalse65930.760
3806581144524Nonecode223NP3 pipes for the Coutyard to Outlet of Water Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 750mm dia Sl.No 20.16, Page No.134 Volume-IIIm3501.753501.7510.0FalseNoneNoneFalseNoneFalse35017.50
3806582144524Nonecode224PLUMBING Providing & fixing Chorinated Poly Venyl Chloride (CPVC) 20 mm dia pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc. (P.No.122, vol-2 I.No.13.32.2 of SR 2023-24 ) 20 mm diam397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3806583144524Nonecode225Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc.for : pipes of SN 4, 75mm dia (P.No.114, I.No.10.2.1, vol 5, of SR 2023-24m227.85227.85150.0FalseNoneNoneFalseNoneFalse34177.50
3806584144524Nonecode226EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7, I.No.9.10, vol 1, of SR 2023-24Cum279.3279.340.0FalseNoneNoneFalseNoneFalse11172.00
3806585144524Nonecode227Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 20 mm nominal bore (P.No.117, I.No.13.15 of SR 2021-22) (vol-2)No761.25761.2550.0FalseNoneNoneFalseNoneFalse38062.50
3806586144524Nonecode228Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix tures complete,,including cutting and making good the walls and floors wherever required (P.No.131, I.No.14.2.1, vol 2, of SR 2023-24No5079.95079.950.0FalseNoneNoneFalseNoneFalse253995.00
3806587144524Nonecode229Providing and fixing Health faucet of approved make confirming to ISI specifications at suitable place as per direction of engineer-in- charge ( Rate is inclusive of cost of materials and fixtures, labour and conveyance of materials to work spot complete.) (2 in 1 tap system) ( Market Rate) Approved Rate as MDRS Aralihalli GangavathiNo1260.01260.050.0FalseNoneNoneFalseNoneFalse63000.00
3806588144524Nonecode230Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.No.133, I.No.14.7A, vol 2, of SR 2023-24No4327.054327.0550.0FalseNoneNoneFalseNoneFalse216352.50
3806589144524Nonecode231Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (P.No.127, I.No.13.59, vol-2 of SR 2023-24)No231.0231.0120.0FalseNoneNoneFalseNoneFalse27720.00
3806590144524Nonecode232Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern I.No. 14.5.1 V-IINo9074.19074.125.0FalseNoneNoneFalseNoneFalse226852.50
3806591144524Nonecode233Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (P.No.135, I.No.14.22B, vol-2 of SR 2023-24)No5840.15840.138.0FalseNoneNoneFalseNoneFalse221923.80
3806592144524Nonecode234Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. (P.No.119, I.No.13.14, vol-2 of SR 2023-24)No888.3888.340.0FalseNoneNoneFalseNoneFalse35532.00
3806593144524Nonecode235Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (P.No.117, I.No.13.2.1, vol 2, of SR 2023-24No300.3300.340.0FalseNoneNoneFalseNoneFalse12012.00
3806594144524Nonecode236KSRB13-6.3-: Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification (P.No.41, I.No.2.79.1, vol-5 of SR 2023-24)No396.9396.915.0FalseNoneNoneFalseNoneFalse5953.50
3806595144524Nonecode237EX P Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 100 mm dia , having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.9 vol-2 of SR 2023-24 )m2650.22650.2150.0FalseNoneNoneFalseNoneFalse397530.00
3806596144524Nonecode238Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 65 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.7 vol-2 of SR 2023-24 )m1470.01470.0120.0FalseNoneNoneFalseNoneFalse176400.00
3806597144524Nonecode239Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 50.00 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.6 , vil-2 of SR 2023-24)m757.05757.05175.0FalseNoneNoneFalseNoneFalse132483.750
3806598144524Nonecode240Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 40 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.5 , vol-2 of SR 2023-24)m500.85500.85100.0FalseNoneNoneFalseNoneFalse50085.00
3806599144524Nonecode241Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 32 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.4, vol-2 of SR 2023-24 )m390.6390.6150.0FalseNoneNoneFalseNoneFalse58590.00
3806600144524Nonecode242Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 25 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.3 , vol-2 of SR 2023-24 )m310.8310.8120.0FalseNoneNoneFalseNoneFalse37296.00
3806601144524Nonecode243Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-32mm (P.No.117, I.No.13.4.2 , vol-2 of SR 2023-24 )No627.9627.920.0FalseNoneNoneFalseNoneFalse12558.00
3806602144524Nonecode244Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-50mm (P.No.117, I.No.13.4.4 , vol-2 of SR 2023-24 )No897.75897.7520.0FalseNoneNoneFalseNoneFalse17955.00
3806603144524Nonecode245Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-65mm (P.No.117, SI.No.13.4.5 , vol-2 of SR 2023-24 )No1481.551481.5520.0FalseNoneNoneFalseNoneFalse29631.00
3806604144524Nonecode246Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-80mm (P.No.117, I.No.13.4.6 , vol-2 of SR 2023-24 )No2180.852180.8510.0FalseNoneNoneFalseNoneFalse21808.50
3806605144524Nonecode247Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 75mm dia.(P.No.114, I.No10.2.1, vol -5 of SR 2023-24)m227.85227.85120.0FalseNoneNoneFalseNoneFalse27342.00
3806606144524Nonecode248Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 110mm dia. (P.No.114, I.No10.2.2, vol -5 of SR 2023-24)m302.4302.4120.0FalseNoneNoneFalseNoneFalse36288.00
3806607144524Nonecode249Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 160mm dia Pipem604.8604.835.0FalseNoneNoneFalseNoneFalse21168.00
3806608144524Nonecode250Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 200mm dia Pipem872.55872.5525.0FalseNoneNoneFalseNoneFalse21813.750
3806609144524Nonecode251Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 250mm dia Pipem1337.71337.725.0FalseNoneNoneFalseNoneFalse33442.50
3806610144524Nonecode252Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m (P.No.10, I.No.1.17.1-(Vol-1) of SR 2023-24)Cum275.1275.112.15FalseNoneNoneFalseNoneFalse3342.4650
3806611144524Nonecode253Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover (P.No.190, I.No. 16.10 of SR 2023-24) (vol-5)No4447.84447.85.0FalseNoneNoneFalseNoneFalse22239.00
3806612144524Nonecode254Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (P.No.190, I.No. 16.9 of SR 2023-24) (vol-5)No5726.75726.75.0FalseNoneNoneFalseNoneFalse28633.50
3806613144524Nonecode255Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (P.No.191, I.No. 16.10 of SR 2023-24) (vol-5)No4447.84447.83.0FalseNoneNoneFalseNoneFalse13343.40
3806614144524Nonecode256Providing and fixing Pressure relief valve suitable for 40 mm dia pipe at 7th floor to reduce pressure due to head , including cost of all accessories ,labour charges etc. complete as directed by engineer in charge. Market Rate Approved rate from MDRS GangavathiNo12600.012600.05.0FalseNoneNoneFalseNoneFalse63000.00
3806615144524Nonecode257Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchNo282.45282.4510.0FalseNoneNoneFalseNoneFalse2824.50
3806616144524Nonecode258Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchNo397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3806617144524Nonecode259Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchNo582.75582.75120.0FalseNoneNoneFalseNoneFalse69930.00
3806618144524Nonecode260Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesNo710.85710.8530.0FalseNoneNoneFalseNoneFalse21325.50
3806619144524Nonecode261Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switchesNo1038.451038.4515.0FalseNoneNoneFalseNoneFalse15576.750
3806620144524Nonecode262Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayNo144.9144.9120.0FalseNoneNoneFalseNoneFalse17388.00
3806621144524Nonecode263Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WayNo166.95166.95500.0FalseNoneNoneFalseNoneFalse83475.00
3806622144524Nonecode264Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3806623144524Nonecode265Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayNo231.0231.06.0FalseNoneNoneFalseNoneFalse1386.00
3806624144524Nonecode266Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayNo274.05274.0590.0FalseNoneNoneFalseNoneFalse24664.50
3806625144524Nonecode267Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayNo334.95334.9510.0FalseNoneNoneFalseNoneFalse3349.50
3806626144524Nonecode268Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleNo143.85143.85150.0FalseNoneNoneFalseNoneFalse21577.50
3806627144524Nonecode269Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleNo169.05169.05500.0FalseNoneNoneFalseNoneFalse84525.00
3806628144524Nonecode270Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleNo183.75183.756.0FalseNoneNoneFalseNoneFalse1102.50
3806629144524Nonecode271Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleNo245.7245.76.0FalseNoneNoneFalseNoneFalse1474.20
3806630144524Nonecode272Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleNo298.2298.290.0FalseNoneNoneFalseNoneFalse26838.00
3806631144524Nonecode273Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleNo361.2361.215.0FalseNoneNoneFalseNoneFalse5418.00
3806632144524Nonecode274Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchNo107.1107.1700.0FalseNoneNoneFalseNoneFalse74970.00
3806633144524Nonecode275Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way SwitchNo174.3174.310.0FalseNoneNoneFalseNoneFalse1743.00
3806634144524Nonecode276Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketNo179.55179.55430.0FalseNoneNoneFalseNoneFalse77206.50
3806635144524Nonecode277Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.No374.85374.85120.0FalseNoneNoneFalseNoneFalse44982.00
3806636144524Nonecode278Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchNo342.3342.35.0FalseNoneNoneFalseNoneFalse1711.50
3806637144524Nonecode279Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketNo247.8247.855.0FalseNoneNoneFalseNoneFalse13629.00
3806638144524Nonecode280Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchNo189.0189.055.0FalseNoneNoneFalseNoneFalse10395.00
3806639144524Nonecode281Supplyin and Fixing Metal Fan Box with Round Hook.No122.85122.85120.0FalseNoneNoneFalseNoneFalse14742.00
3806640144524Nonecode282Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20AmpsNo1019.551019.556.0FalseNoneNoneFalseNoneFalse6117.30
3806641144524Nonecode283Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30AmpsNo1785.01785.03.0FalseNoneNoneFalseNoneFalse5355.00
3806642144524Nonecode284Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.33000.0FalseNoneNoneFalseNoneFalse207900.00
3806643144524Nonecode285Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.9878.0FalseNoneNoneFalseNoneFalse71908.20
3806644144524Nonecode286Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thickm108.15108.1550.0FalseNoneNoneFalseNoneFalse5407.50
3806645144524Nonecode287Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.42000.0FalseNoneNoneFalseNoneFalse142800.00
3806646144524Nonecode288Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.951500.0FalseNoneNoneFalseNoneFalse124425.00
3806647144524Nonecode289Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thickm103.95103.9560.0FalseNoneNoneFalseNoneFalse6237.00
3806648144524Nonecode290Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200 x 200 x 65 mmNo365.4365.42.0FalseNoneNoneFalseNoneFalse730.80
3806649144524Nonecode291Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxNo58.858.8250.0FalseNoneNoneFalseNoneFalse14700.00
3806650144524Nonecode292Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxNo64.0564.05100.0FalseNoneNoneFalseNoneFalse6405.00
3806651144524Nonecode293Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 20mmm19.9519.9530.0FalseNoneNoneFalseNoneFalse598.50
3806652144524Nonecode294Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mmm23.123.130.0FalseNoneNoneFalseNoneFalse693.00
3806653144524Nonecode295Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mmm30.4530.4520.0FalseNoneNoneFalseNoneFalse609.00
3806654144524Nonecode296Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 -4C x 6 mm2m344.4344.4500.0FalseNoneNoneFalseNoneFalse172200.00
3806655144524Nonecode297Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm27.327.34000.0FalseNoneNoneFalseNoneFalse109200.00
3806656144524Nonecode298Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm44.144.19500.0FalseNoneNoneFalseNoneFalse418950.00
3806657144524Nonecode299Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm66.1566.151500.0FalseNoneNoneFalseNoneFalse99225.00
3806658144524Nonecode300Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmm96.696.6300.0FalseNoneNoneFalseNoneFalse28980.00
3806659144524Nonecode301Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way TP & NNo6395.556395.5510.0FalseNoneNoneFalseNoneFalse63955.50
3806660144524Nonecode302Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way TP & NNo9171.759171.752.0FalseNoneNoneFalseNoneFalse18343.50
3806661144524Nonecode303Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo435.75435.75320.0FalseNoneNoneFalseNoneFalse139440.00
3806662144524Nonecode304Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNo775.95775.9530.0FalseNoneNoneFalseNoneFalse23278.50
3806663144524Nonecode305Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps DPNo1113.01113.04.0FalseNoneNoneFalseNoneFalse4452.00
3806664144524Nonecode306Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNNo3196.23196.210.0FalseNoneNoneFalseNoneFalse31962.00
3806665144524Nonecode307Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 poleNo4490.854490.8530.0FalseNoneNoneFalseNoneFalse134725.50
3806666144524Nonecode308Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 poleNo5822.255822.2510.0FalseNoneNoneFalseNoneFalse58222.50
3806667144524Nonecode3091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 25 sqmmKm188836.2188836.20.2FalseNoneNoneFalseNoneFalse37767.240
3806668144524Nonecode3101.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km391875.75391875.750.2FalseNoneNoneFalseNoneFalse78375.150
3806669144524Nonecode311Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm32695.9532695.950.2FalseNoneNoneFalseNoneFalse6539.190
3806670144524Nonecode312GI Pipe, 100 mm Dia for drain crossing, cable raising etc.,m1296.751296.7512.0FalseNoneNoneFalseNoneFalse15561.00
3806671144524Nonecode313Brass cable gland 32mm diaNo99.7599.7520.0FalseNoneNoneFalseNoneFalse1995.00
3806672144524Nonecode314Brass cable gland 45mm diaNo206.85206.8530.0FalseNoneNoneFalseNoneFalse6205.50
3806673144524Nonecode315Aluminium end terminal lug 10 sqmmNo2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3806674144524Nonecode316Aluminium end terminal lug 16 sqmmNo2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3806675144524Nonecode317Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 GmNo147.0147.020.0FalseNoneNoneFalseNoneFalse2940.00
3806676144524Nonecode318Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No4468.84468.88.0FalseNoneNoneFalseNoneFalse35750.40
3806677144524Nonecode319Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripm86.186.150.0FalseNoneNoneFalseNoneFalse4305.00
3806678144524Nonecode320Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI stripm134.4134.420.0FalseNoneNoneFalseNoneFalse2688.00
3806679144524Nonecode321Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm GI Plate.No918.75918.754.0FalseNoneNoneFalseNoneFalse3675.00
3806680144524Nonecode322Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper stripm598.5598.550.0FalseNoneNoneFalseNoneFalse29925.00
3806681144524Nonecode323Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. strip 25x6mm Copper stripm1155.01155.050.0FalseNoneNoneFalseNoneFalse57750.00
3806682144524Nonecode324Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plateNo7792.057792.052.0FalseNoneNoneFalseNoneFalse15584.10
3806683144524Nonecode325Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIless then 70%. efficacy less then100 lumen per W, 120degree beam spread, lifeless then 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF less then 0.95, power loss shouldgrater then 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 10-12WNo1332.451332.455.0FalseNoneNoneFalseNoneFalse6662.250
3806684144524Nonecode326Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIless then 70%. efficacy less then100 lumen per W, 120degree beam spread, lifeless then 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF less then 0.95, power loss shouldgrater then 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 15-18WNo1754.551754.5525.0FalseNoneNoneFalseNoneFalse43863.750
3806685144524Nonecode327Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less then 80. Power Input: 220-240V @ 50/60Hz & Power factor less then0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9/10 wNo578.55578.5535.0FalseNoneNoneFalseNoneFalse20249.250
3806686144524Nonecode328Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less then 80. Power Input: 220-240V @ 50/60Hz & Power factor less then0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 WNo1332.451332.45300.0FalseNoneNoneFalseNoneFalse399735.00
3806687144524Nonecode329Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIless then 70%. efficacy less then100 lumen per watt, 120degree beam spread, lifeless then 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF less then 0.95, power loss should grater then 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 36wattNo4780.654780.6520.0FalseNoneNoneFalseNoneFalse95613.00
3806688144524Nonecode330Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT less then 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire less then IK08. Power Factor less then0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencyless then130lm/w, nominal CRI less then75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNo6291.66291.66.0FalseNoneNoneFalseNoneFalse37749.60
3806689144524Nonecode331Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm)No3117.453117.4540.0FalseNoneNoneFalseNoneFalse124698.00
3806690144524Nonecode332Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 56" Sweep 5 Star (1400 mm)No4991.74991.7120.0FalseNoneNoneFalseNoneFalse599004.00
3806691144524Nonecode333Supplying & Fixing of 70-150 Watts lamp holder 2 PinNo66.1566.1520.0FalseNoneNoneFalseNoneFalse1323.00
3806692144524Nonecode334Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersNo128.1128.130.0FalseNoneNoneFalseNoneFalse3843.00
3806693144524Nonecode335Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.No330.75330.75100.0FalseNoneNoneFalseNoneFalse33075.00
3806694144524Nonecode336Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.No742.35742.3540.0FalseNoneNoneFalseNoneFalse29694.00
3806695144524Nonecode337Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.No514.5514.5350.0FalseNoneNoneFalseNoneFalse180075.00
3806696144524Nonecode338Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthNo1534.051534.056.0FalseNoneNoneFalseNoneFalse9204.30
3806697144524Nonecode339Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNo1359.751359.756.0FalseNoneNoneFalseNoneFalse8158.50
3806698144524Nonecode340Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.No170.1170.16.0FalseNoneNoneFalseNoneFalse1020.60
3806699144524Nonecode341MAIN LT PANEL Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSqm0.450.45150000.0FalseNoneNoneFalseNoneFalse67500.00
3806700144524Nonecode342Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Stripsm2588.252588.255.0FalseNoneNoneFalseNoneFalse12941.250
3806701144524Nonecode343Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm320.25320.2520.0FalseNoneNoneFalseNoneFalse6405.00
3806702144524Nonecode344Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm793.8793.820.0FalseNoneNoneFalseNoneFalse15876.00
3806703144524Nonecode345Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo435.75435.755.0FalseNoneNoneFalseNoneFalse2178.750
3806704144524Nonecode346Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo775.95775.954.0FalseNoneNoneFalseNoneFalse3103.80
3806705144524Nonecode347Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A TPNNo1802.851802.8512.0FalseNoneNoneFalseNoneFalse21634.20
3806706144524Nonecode348Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNo9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3806707144524Nonecode349Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CNo540.75540.7510.0FalseNoneNoneFalseNoneFalse5407.50
3806708144524Nonecode350Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape WoundNo590.1590.110.0FalseNoneNoneFalseNoneFalse5901.00
3806709144524Nonecode351Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V, 125 ANo77527.877527.81.0FalseNoneNoneFalseNoneFalse77527.80
3806710144524Nonecode352EXTERNAL STREET LIGHTING Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32No16275.016275.04.0FalseNoneNoneFalseNoneFalse65100.00
3806711144524Nonecode353Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT less then 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire less then IK08. Power Factor less then0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencyless then130lm/w, nominal CRI less then75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNo6291.66291.64.0FalseNoneNoneFalseNoneFalse25166.40
3806712144524Nonecode354Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNo1359.751359.754.0FalseNoneNoneFalseNoneFalse5439.00
3806713144524Nonecode355Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT less then 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire less then IK08. Power Factor less then0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr HeightNo4755.44755.44.0FalseNoneNoneFalseNoneFalse19021.60
3806714144524Nonecode356Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.No170.1170.14.0FalseNoneNoneFalseNoneFalse680.40
3806715144524Nonecode357Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNo775.95775.953.0FalseNoneNoneFalseNoneFalse2327.850
3806716144524Nonecode358Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting.No2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3806717144524Nonecode359Supplying and fixing of solar Lux level street light control switch single phase including suitable capacity contactor- 8KWNo12621.012621.01.0FalseNoneNoneFalseNoneFalse12621.00
3806718144524Nonecode360Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.3350.0FalseNoneNoneFalseNoneFalse24255.00
3806719144524Nonecode361Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.935.0FalseNoneNoneFalseNoneFalse2866.50
3806720144524Nonecode362Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.445.0FalseNoneNoneFalseNoneFalse3213.00
3806721144524Nonecode363Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.9545.0FalseNoneNoneFalseNoneFalse3732.750
3806722144524Nonecode364IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.No20200.020200.015.0FalseNoneNoneFalseNoneFalse303000.00
3806723144524Nonecode365IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.No21700.021700.03.0FalseNoneNoneFalseNoneFalse65100.00
3806724144524Nonecode366Supplying and drawing UTP-CAT 6E LAN cablem41.841.8800.0FalseNoneNoneFalseNoneFalse33440.00
3806725144524Nonecode367Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as requiredNo14500.014500.01.0FalseNoneNoneFalseNoneFalse14500.00
3806726144524Nonecode368Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as requiredNo40250.040250.01.0FalseNoneNoneFalseNoneFalse40250.00
3806727144524Nonecode369Supply and Installation of I/OsNo125.0125.050.0FalseNoneNoneFalseNoneFalse6250.00
3806728144524Nonecode370Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as requiredNo225.0225.010.0FalseNoneNoneFalseNoneFalse2250.00
3806729144524Nonecode371Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as requiredNo285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3806730144524Nonecode372Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as requiredNo60000.060000.01.0FalseNoneNoneFalseNoneFalse60000.00
3806731144524Nonecode373Design,supplying,erectingtestingandcommissioningof-Passenger/Bed-cum passengerhospitalliftwithspeedof1mtrpersecond,variablevoltagevariablefrequencydrive,withorwithoutmachineroomfortheavailablewellsize,operatingat415V3phase50cyclesACsupply,powdercoated/StainlessSteelcarentrancedoorsenclosureswithsuitablecolourvinylflooring,LEDcarillumination,emergencylight,intercomandfanasdesiredbytheuser,centralopening/sideopeningdoorwithorwithoutattendantoperation,7segmentdisplaybuttons,callregisterindicator,firemandrive,SShandrailsinsidecar,fulllengthinfraredcurtainincardoor,automaticrescuedevicewithbatteries,voiceannouncinginregional/internationallanguages,Braillebuttonswithoneyearwarrantyandmaintenancewithnecessaryscaffoldingandminorcivilworkslikefixingofguiderail,counterweightetc.,ThetotalproductandservicesshalladheretoIS14665/2016(withlatestamendments)part/section1to5withregardstogeneralguidelinesoffiresafetyrateddoors,MRLLbeams,pressureswitch,manualchangeoverfordoorsduringemergency,ARDof10timeswithsufficientbatterybackupandstandarddimensionsofchaircaranddooropeningsforallsizesandcapacitiesofliftsincludingfitnesscertificateanddulyobservingallothersafetynormsprescribedandadheretoCPWDspecifications,PCBNorms,NationalElectricityCode(NEC),NBC-2016,IECandKarnatakaStateLifts,EscalatorsandPassengersConveyersAct 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. With Out Machine Room-PC FinishJob1666957.371666957.371.0FalseNoneNoneFalseNoneFalse1666957.370
3806732144524Nonecode374Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles)No21974.421974.42.0FalseNoneNoneFalseNoneFalse43948.80
3806733144524Nonecode375Erection DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WLNo5640.65640.62.0FalseNoneNoneFalseNoneFalse11281.20
3806734144524Nonecode376Supply& erection of 11 kV, 45 KN Polymeric InsulatorNo195.3195.312.0FalseNoneNoneFalseNoneFalse2343.60
3806735144524Nonecode377Supply of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.53.0FalseNoneNoneFalseNoneFalse3685.50
3806736144524Nonecode378Erection of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.653.0FalseNoneNoneFalseNoneFalse1867.950
3806737144524Nonecode379Supply of Spiral Earth ElectrodeNo250.95250.953.0FalseNoneNoneFalseNoneFalse752.850
3806738144524Nonecode380Erection of Spiral Earth ElectrodeNo97.6597.653.0FalseNoneNoneFalseNoneFalse292.950
3806739144524Nonecode381Supply& fixing of Guy concreting with Boulders, Mud and SandNo262.5262.53.0FalseNoneNoneFalseNoneFalse787.50
3806740144524Nonecode382Supply of Caution/Danger BoardNo157.5157.52.0FalseNoneNoneFalseNoneFalse315.00
3806741144524Nonecode383Fixing of Caution/Danger BoardNo84.084.02.0FalseNoneNoneFalseNoneFalse168.00
3806742144524Nonecode384Supply of Anti Climbing Device (12 Mtr GI Barbed WireNo93.4593.453.0FalseNoneNoneFalseNoneFalse280.350
3806743144524Nonecode385Erection of Anti Climbing Device (12 Mtr GI Barbed WireNo44.144.13.0FalseNoneNoneFalseNoneFalse132.30
3806744144524Nonecode386Supply and fixing of 11 kV, 400 Amps Double Break GOSNo22323.022323.02.0FalseNoneNoneFalseNoneFalse44646.00
3806745144524Nonecode387Fixing of 11 kV, 400 Amps Double Break GOSNo1274.71274.72.0FalseNoneNoneFalseNoneFalse2549.40
3806746144524Nonecode388Supply of H-Frame for mounting GOSNo4548.64548.62.0FalseNoneNoneFalseNoneFalse9097.20
3806747144524Nonecode389fixing of H-Frame for mounting GOSNo339.15339.152.0FalseNoneNoneFalseNoneFalse678.30
3806748144524Nonecode390Supply of DOLO Cut OutNo6165.66165.62.0FalseNoneNoneFalseNoneFalse12331.20
3806749144524Nonecode391Erection of DOLO Cut OutNo248.85248.852.0FalseNoneNoneFalseNoneFalse497.70
3806750144524Nonecode39211KV EXTENSION Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785No7429.87429.82.0FalseNoneNoneFalseNoneFalse14859.60
3806751144524Nonecode393Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785No1829.11829.12.0FalseNoneNoneFalseNoneFalse3658.20
3806752144524Nonecode394Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNo678.3678.32.0FalseNoneNoneFalseNoneFalse1356.60
3806753144524Nonecode395Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNo285.6285.62.0FalseNoneNoneFalseNoneFalse571.20
3806754144524Nonecode396Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)No215.25215.256.0FalseNoneNoneFalseNoneFalse1291.50
3806755144524Nonecode397Supply and fixing of 11 kV, 45 KN Polymeric InsulatorNo195.3195.36.0FalseNoneNoneFalseNoneFalse1171.80
3806756144524Nonecode398Supply of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.52.0FalseNoneNoneFalseNoneFalse2457.00
3806757144524Nonecode399Erection of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.652.0FalseNoneNoneFalseNoneFalse1245.30
3806758144524Nonecode400Supply of Rabbit ACSR ConductorKm48545.748545.71.0FalseNoneNoneFalseNoneFalse48545.70
3806759144524Nonecode401Erection of Rabbit ACSR ConductorKm4579.054579.051.0FalseNoneNoneFalseNoneFalse4579.050
3806760144524Nonecode402Supply and fixing of PG Clamps for Rabbit ConductorNo107.1107.115.0FalseNoneNoneFalseNoneFalse1606.50
3806761144524Nonecode403Supply of Spiral Earth ElectrodeNo250.95250.952.0FalseNoneNoneFalseNoneFalse501.90
3806762144524Nonecode404Erection of Spiral Earth ElectrodeNo97.6597.652.0FalseNoneNoneFalseNoneFalse195.30
3806763144524Nonecode405Supply of EG Stirrups with GI wire lacingNo289.8289.82.0FalseNoneNoneFalseNoneFalse579.60
3806764144524Nonecode406Erection of EG Stirrups with GI wire lacingNo168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3806765144524Nonecode407Guy concreting with Boulders, Mud and SandNo262.5262.52.0FalseNoneNoneFalseNoneFalse525.00
3806766144524Nonecode408Supply of Caution/Danger BoardNo157.5157.53.0FalseNoneNoneFalseNoneFalse472.50
3806767144524Nonecode409Erection of Caution/Danger BoardNo84.084.03.0FalseNoneNoneFalseNoneFalse252.00
3806768144524Nonecode410Supply of Anti Climbing Device (12 Mtr GI Barbed WireNo93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3806769144524Nonecode411Erection of Anti Climbing Device (12 Mtr GI Barbed WireNo44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3806770144524Nonecode412Erection of 3 Phase, 11kV/433V, 63 kVA BEE 4/5 Star Rated Distribution Transformer Centre Using DPTS Using PSCC Pole - 9 Mtr Long, 300 Kg WL supplying of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No29051.429051.41.0FalseNoneNoneFalseNoneFalse29051.40
3806771144524Nonecode413supplying & fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)No215.25215.253.0FalseNoneNoneFalseNoneFalse645.750
3806772144524Nonecode414supplying & fixing of 11 kV, 45 KN Polymeric InsulatorNo195.3195.33.0FalseNoneNoneFalseNoneFalse585.90
3806773144524Nonecode415Supplying of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.54.0FalseNoneNoneFalseNoneFalse4914.00
3806774144524Nonecode416Supplying of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo191672.25191672.251.0FalseNoneNoneFalseNoneFalse191672.250
3806775144524Nonecode417Supplying of Earthing materials pipe type for grounding (Single Electrode with accessories)No1815.451815.453.0FalseNoneNoneFalseNoneFalse5446.350
3806776144524Nonecode418Supplying of Caution/Danger BoardNo157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3806777144524Nonecode419supplying of Anti Climbing Device (12 Mtr GI Barbed Wire)No93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3806778144524Nonecode420Supplying & fixing of GI Wire 8 SWGKg78.7978.795.0FalseNoneNoneFalseNoneFalse393.950
3806779144524Nonecode421Supplying & fixing of Guy wire 7/10 SWGKg81.0981.0910.0FalseNoneNoneFalseNoneFalse810.90
3806780144524Nonecode422Supplying & fixing of 11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA, Polymeric type with ground disconnectorNo4989.64989.61.0FalseNoneNoneFalseNoneFalse4989.60
3806781144524Nonecode423a) Supplying of LT Protection Kit for 63 kVANo2124.152124.152.0FalseNoneNoneFalseNoneFalse4248.30
3806782144524Nonecode424b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmmm116.85116.8540.0FalseNoneNoneFalseNoneFalse4674.00
3806783144524Nonecode425b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT ii) Heavy Duty Long Barrel Copper Lug - 95 SqmmNo135.45135.454.0FalseNoneNoneFalseNoneFalse541.80
3806784144524Nonecode426b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iii) PG Clamp - Rabbit to 95 SqmmNo147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
3806785144524Nonecode427b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iv) Spacer for DTC WiringNo44.144.18.0FalseNoneNoneFalseNoneFalse352.80
3806786144524Nonecode428b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)No277.2277.22.0FalseNoneNoneFalseNoneFalse554.40
3806787144524Nonecode429c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No5905.25905.21.0FalseNoneNoneFalseNoneFalse5905.20
3806788144524Nonecode430d) LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo3565.83565.81.0FalseNoneNoneFalseNoneFalse3565.80
3806789144524Nonecode431Supplying of 11 kV, Solid Core Type HG Fuse UnitNo1122.451122.451.0FalseNoneNoneFalseNoneFalse1122.450
3806790144524Nonecode432suppying of 11 kV, 200 Amps, Single Break GOSNo9922.59922.51.0FalseNoneNoneFalseNoneFalse9922.50
3806791144524Nonecode433Fixing of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No7332.157332.151.0FalseNoneNoneFalseNoneFalse7332.150
3806792144524Nonecode434Fixing of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.654.0FalseNoneNoneFalseNoneFalse2490.60
3806793144524Nonecode435Fixing of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo1252.651252.651.0FalseNoneNoneFalseNoneFalse1252.650
3806794144524Nonecode436Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories)No996.45996.453.0FalseNoneNoneFalseNoneFalse2989.350
3806795144524Nonecode437Fixing of Caution/Danger BoardNo84.084.01.0FalseNoneNoneFalseNoneFalse84.00
3806796144524Nonecode438Fixing Anti Climbing Device (12 Mtr GI Barbed Wire)No44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3806797144524Nonecode439Fixing of Guy concreting with Boulders, Mud and SandNo262.5262.54.0FalseNoneNoneFalseNoneFalse1050.00
3806798144524Nonecode440a) Fixing of LT Protection Kit for 63 kVANo373.8373.82.0FalseNoneNoneFalseNoneFalse747.60
3806799144524Nonecode441b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmm ii) Heavy Duty Long Barrel Copper Lug - 95 Sqmm iii) PG Clamp - Rabbit to 95 Sqmm iv) Spacer for DTC Wiring v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)No996.45996.451.0FalseNoneNoneFalseNoneFalse996.450
3806800144524Nonecode442c) fixing of LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No908.25908.251.0FalseNoneNoneFalseNoneFalse908.250
3806801144524Nonecode443d) fixing of LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3806802144524Nonecode444fixing of 11 kV, Solid Core Type HG Fuse UnitNo248.85248.851.0FalseNoneNoneFalseNoneFalse248.850
3806803144524Nonecode445Fixing of 11 kV, 200 Amps, Single Break GOSNo1159.21159.21.0FalseNoneNoneFalseNoneFalse1159.20
3806804144524Nonecode446SUMP TANK EARTH WORK Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m Page No. 8,Sl. No.1.14Cum107.1107.156.0FalseNoneNoneFalseNoneFalse5997.60
3806805144524Nonecode447PCC BED Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.2, Page No.15Cum5947.25947.24.0FalseNoneNoneFalseNoneFalse23788.80
3806806144524Nonecode448EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7Cum279.3279.33.69FalseNoneNoneFalseNoneFalse1030.6170
3806807144524Nonecode449Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24Cum7185.027185.024.85FalseNoneNoneFalseNoneFalse34847.3470
3806808144524Nonecode450RCC Work Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-ICum7903.677903.678.09FalseNoneNoneFalseNoneFalse63940.69030
3806809144524Nonecode451Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum10777.7310777.734.85FalseNoneNoneFalseNoneFalse52271.99050
3806810144524Nonecode452PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42 Volume-IISqm404.25404.2588.0FalseNoneNoneFalseNoneFalse35574.00
3806811144524Nonecode453Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. Sl. No. 8.12, Page No.43 Volume-IISqm67.267.288.0FalseNoneNoneFalseNoneFalse5913.60
3806812144524Nonecode454KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification (Page No. 75, Sl. No. 11.45)No283.5283.510.0FalseNoneNoneFalseNoneFalse2835.00
3806813144524Nonecode455STEEL Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Sl. No. 2.11 a, Page No.18 Volume-IKg82961.5582961.553.84FalseNoneNoneFalseNoneFalse318572.3520
3806814144524Nonecode456Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete V0L-V SL No 12.4 V-5 PG:140No5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3806815144524Nonecode457Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50mtr 12.2.1m324.45324.4550.0FalseNoneNoneFalseNoneFalse16222.50
3806816144524Nonecode458Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50 to 100 mtr 12.2.2m406.35406.3550.0FalseNoneNoneFalseNoneFalse20317.50
3806817144524Nonecode459Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 100 to 150 mtr 12.2.3m432.6432.650.0FalseNoneNoneFalseNoneFalse21630.00
3806818144524Nonecode460Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 150 to 200mtr 12.2.4m501.9501.950.0FalseNoneNoneFalseNoneFalse25095.00
3806819144524Nonecode461Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 VOL-V SL No 10.1.8 pg 113 V-5 140 mm dia casing pipesm613.2613.2180.0FalseNoneNoneFalseNoneFalse110376.00
3806820144524Nonecode462Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (VOL-V) SL No 13.15.7 V-6 PG: 152No42850.542850.51.0FalseNoneNoneFalseNoneFalse42850.50
3806821144524Nonecode463Supplyinganddrawing3coreflatPVCsheathedsubmersiblepumpcablemanufacturedwithelectrolyticgradecopperwithflexiblecopperwithlowresistanceconductorconfirmingto13:8130 1984andvirgingradePVCinsulationandpowdercoatingextrudedPVCsheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 mm2 SL No: 2.6.2 V-6 PG: 7m176.4176.4330.0FalseNoneNoneFalseNoneFalse58212.00
3806822144524Nonecode464Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valves VOL-V ) 50 mm Size = 1No SL No: 11.15.6 pg 133 V-5No1772.41772.41.0FalseNoneNoneFalseNoneFalse1772.40
3806823144524Nonecode465Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (IT NO 28.1 PG NO 162 ) VOL-V 50 mm Size = 1No SL No: 13.25.1 pg 154 V-5No1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3806824144524Nonecode466Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter (6 to 15 HP pumps) IT NO 30.2 & PG NO-162 VOL-V SL No: 13.24.3 pg 155 V-5No18375.018375.01.0FalseNoneNoneFalseNoneFalse18375.00
3806825144524Nonecode467Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ( IT NO 38 & PG NO-163 ,VOL-V) SL No: 13.32 pg 156 V-5No6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3806826144524Nonecode468Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 7.5 HP, size 100x100 Head 195M, Discharge 1200 LPM SL No:13.40.6 PG: 157 V-5No32046.032046.01.0FalseNoneNoneFalseNoneFalse32046.00
3806827144524Nonecode469Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. All items are of ISI standards. 2. After commissioning of plant necessary testing to be done for the 3. Satisfaction of the Engineer in charge. 4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. Page No. 251 ,Sl. No-22.2.1 B. VOL-5 STP ( 25 KLD)No1359750.01359750.01.0FalseNoneNoneFalseNoneFalse1359750.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17240482580000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17240482580000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17240482580000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17240482580000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17240482580000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17240482640000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17240482670000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17240482710000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17240482750000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17240482780000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17240482810000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17240482850000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17240482880000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17240482910000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17240482950000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17240482980000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17240483010000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17240483040000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17240483100000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17240483140000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid