createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724046340069
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1025000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-09-2024 16:00:00
tenderQueryClose02-09-2024 16:00:00
technicalBidOpen21-09-2024 16:00:00
publishedDate20-08-2024 19:04:29
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate03-09-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1724046340089
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT264
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Yalavara Village, Jevargi Taluk, Kalaburagi District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Yalavara Village, Jevargi Taluk, Kalaburagi District
categoryWORKS
categoryTextWorks
ecv68188447.99
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount68188448.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/322/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17240463400000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Yalavara Village, Jevargi Taluk, Kalaburagi District68188447.99
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3804953144495Nonecode01JUNGLE CLEARANCE Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of light jungle SR 2023-24 Page No. 9,Sl. No.2.5 A. VOL-3 ii a Rate per 100SqmSqm412.65412.657.02FalseNoneNoneFalseNoneFalse2896.8030
3804954144495Nonecode02Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Page No. 5,Sl. No.1.1 . VOL-1Sqm95.5595.55702.0FalseNoneNoneFalseNoneFalse67076.10
3804955144495Nonecode03EARTH WORK FOR BUILDING Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m SR 2023-24 Page No. 8,Sl. No.1.14.1 A. VOL-1Cum107.1107.1974.77FalseNoneNoneFalseNoneFalse104397.8670
3804956144495Nonecode04Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In ordinary/soft rock without blasting SR 2023-24 (P.No.8, Vol-1, SI.No.1.15.1 ) soft rock without blasting 20%Cum381.15381.15246.6813FalseNoneNoneFalseNoneFalse94022.5774950
3804957144495Nonecode05CC 1:3:6 For Bed ConcreteProviding and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarseaggregates SR 2023-24 Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4578.41FalseNoneNoneFalseNoneFalse493077.36450
3804958144495Nonecode06ANTI TERMITE TREATMENT Providing and injecting chemical emulsion for Preconstructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications Sl.No 4.1/ Page No. 5- VOL-2Sqm123.9123.9525.0FalseNoneNoneFalseNoneFalse65047.50
3804959144495Nonecode07RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1Cum7185.027185.02415.06FalseNoneNoneFalseNoneFalse2982214.40120
3804960144495Nonecode08RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1 PEDESTALCum7318.087318.0812.42FalseNoneNoneFalseNoneFalse90890.55360
3804961144495Nonecode09RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I upto plinthCum12214.7612214.7612.6FalseNoneNoneFalseNoneFalse153905.9760
3804962144495Nonecode10RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum12214.7612214.7625.92FalseNoneNoneFalseNoneFalse316606.57920
3804963144495Nonecode11RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum12336.912336.925.92FalseNoneNoneFalseNoneFalse319772.4480
3804964144495Nonecode12RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum12460.2712460.2725.92FalseNoneNoneFalseNoneFalse322970.19840
3804965144495Nonecode13RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum12584.8712584.8725.92FalseNoneNoneFalseNoneFalse326199.83040
3804966144495Nonecode14RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum12710.7212710.7225.92FalseNoneNoneFalseNoneFalse329461.86240
3804967144495Nonecode15RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12837.8312837.831.73FalseNoneNoneFalseNoneFalse22209.44590
3804968144495Nonecode16RCC COLUMN(DUMMY COLUMNS) Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 ) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Page 15, Sl. No.2.1.4, Volume-ICum11097.3511097.356.48FalseNoneNoneFalseNoneFalse71910.8280
3804969144495Nonecode17PCC M15 FOR DPC Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Page 15, Sl. No.2.1.4, Volume-ICum6527.856527.851.54FalseNoneNoneFalseNoneFalse10052.8890
3804970144495Nonecode18EARTH REFILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.3699.97FalseNoneNoneFalseNoneFalse195501.6210
3804971144495Nonecode19EARTH FILLING UPTO FLOORING PCC Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.3518.49FalseNoneNoneFalseNoneFalse144814.2570
3804972144495Nonecode20Balance Soil have to brought from Outside Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SL.No 1.8, Page No.7 Volume-ICum497.7497.7345.06FalseNoneNoneFalseNoneFalse171736.3620
3804973144495Nonecode21Flooring Bed Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4543.51FalseNoneNoneFalseNoneFalse273610.45950
3804974144495Nonecode22RCC M25 FOR PLINTH BEAM Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.---- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.4.3 Page No.17 VOL-1Cum9979.29979.276.05FalseNoneNoneFalseNoneFalse758918.160
3804975144495Nonecode23CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II GROUND FLOORSqm1375.51375.5292.77FalseNoneNoneFalseNoneFalse402705.1350
3804976144495Nonecode24CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FIRST FLOORSqm1389.261389.26264.95FalseNoneNoneFalseNoneFalse368084.4370
3804977144495Nonecode25CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II SECOND FLOORSqm1403.151403.15264.95FalseNoneNoneFalseNoneFalse371764.59250
3804978144495Nonecode26CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II THIRD FLOORSqm1417.181417.18264.95FalseNoneNoneFalseNoneFalse375481.8410
3804979144495Nonecode27CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FOURTH FLOORSqm1431.351431.35264.95FalseNoneNoneFalseNoneFalse379236.18250
3804980144495Nonecode28CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II GROUND FLOORSqm1292.551292.55308.34FalseNoneNoneFalseNoneFalse398544.8670
3804981144495Nonecode29CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FIRST FLOORSqm1305.481305.48486.89FalseNoneNoneFalseNoneFalse635625.15720
3804982144495Nonecode30CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II SECOND FLOORSqm1318.531318.53486.89FalseNoneNoneFalseNoneFalse641979.07170
3804983144495Nonecode31CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II THIRD FLOORSqm1331.721331.72486.89FalseNoneNoneFalseNoneFalse648401.15080
3804984144495Nonecode32CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FOURTH FLOORSqm1345.031345.03486.89FalseNoneNoneFalseNoneFalse654881.65670
3804985144495Nonecode33CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II HEAD ROOM DOORSqm1358.481358.48159.94FalseNoneNoneFalseNoneFalse217275.29120
3804986144495Nonecode34CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II GROUND FLOORSqm1159.21159.248.62FalseNoneNoneFalseNoneFalse56360.3040
3804987144495Nonecode35CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FIRST FLOORSqm1170.791170.7997.23FalseNoneNoneFalseNoneFalse113835.91170
3804988144495Nonecode36CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II SECOND FLOORSqm1182.51182.597.23FalseNoneNoneFalseNoneFalse114974.4750
3804989144495Nonecode37CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II THIRD FLOORSqm1194.321194.3297.23FalseNoneNoneFalseNoneFalse116123.73360
3804990144495Nonecode38CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FOURTH FLOORSqm1206.271206.2797.23FalseNoneNoneFalseNoneFalse117285.63210
3804991144495Nonecode39RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.247.73FalseNoneNoneFalseNoneFalse88865.93520
3804992144495Nonecode40RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.211.08FalseNoneNoneFalseNoneFalse128652.0960
3804993144495Nonecode41RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3111.08FalseNoneNoneFalseNoneFalse129938.59480
3804994144495Nonecode42RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5911.08FalseNoneNoneFalseNoneFalse131238.05720
3804995144495Nonecode43RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0311.08FalseNoneNoneFalseNoneFalse132550.37240
3804996144495Nonecode44RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOM DOORCum12082.6612082.660.98FalseNoneNoneFalseNoneFalse11841.00680
3804997144495Nonecode45CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I GROUND FLOORCum9465.389465.383.75FalseNoneNoneFalseNoneFalse35495.1750
3804998144495Nonecode46CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FIRST FLOORCum9560.049560.045.82FalseNoneNoneFalseNoneFalse55639.43280
3804999144495Nonecode47CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I SECOND FLOORCum9655.649655.645.82FalseNoneNoneFalseNoneFalse56195.82480
3805000144495Nonecode48CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I THIRD FLOORCum9752.199752.195.82FalseNoneNoneFalseNoneFalse56757.74580
3805001144495Nonecode49CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FOURTH FLOORCum9849.719849.715.82FalseNoneNoneFalseNoneFalse57325.31220
3805002144495Nonecode50CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I HEAD ROOM DOORCum9948.219948.210.49FalseNoneNoneFalseNoneFalse4874.62290
3805003144495Nonecode51RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.2441.57FalseNoneNoneFalseNoneFalse477898.69680
3805004144495Nonecode52RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.248.13FalseNoneNoneFalseNoneFalse558847.0560
3805005144495Nonecode53RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3148.13FalseNoneNoneFalseNoneFalse564435.43030
3805006144495Nonecode54RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5948.13FalseNoneNoneFalseNoneFalse570080.11670
3805007144495Nonecode55RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0348.13FalseNoneNoneFalseNoneFalse575780.63390
3805008144495Nonecode56RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12082.6612082.662.32FalseNoneNoneFalseNoneFalse28031.77120
3805009144495Nonecode57RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I Ground floorCum10777.7310777.7380.25FalseNoneNoneFalseNoneFalse864912.83250
3805010144495Nonecode58RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.578.0FalseNoneNoneFalseNoneFalse849069.00
3805011144495Nonecode59RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.3678.0FalseNoneNoneFalseNoneFalse857560.080
3805012144495Nonecode60RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.378.0FalseNoneNoneFalseNoneFalse866135.40
3805013144495Nonecode61RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.3478.0FalseNoneNoneFalseNoneFalse874796.520
3805014144495Nonecode62RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.59.9FalseNoneNoneFalseNoneFalse112142.250
3805015144495Nonecode63RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum10777.7310777.734.16FalseNoneNoneFalseNoneFalse44835.35680
3805016144495Nonecode64RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.54.16FalseNoneNoneFalseNoneFalse45283.680
3805017144495Nonecode65RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.364.16FalseNoneNoneFalseNoneFalse45736.53760
3805018144495Nonecode66RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.34.16FalseNoneNoneFalseNoneFalse46193.8880
3805019144495Nonecode67RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.344.16FalseNoneNoneFalseNoneFalse46655.81440
3805020144495Nonecode68RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.54.16FalseNoneNoneFalseNoneFalse47122.40
3805021144495Nonecode69TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I GROUND FLOORTonne93929.8593929.8554.16FalseNoneNoneFalseNoneFalse5087240.6760
3805022144495Nonecode70TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FIRST FLOORTonne94869.1594869.1523.78FalseNoneNoneFalseNoneFalse2255988.3870
3805023144495Nonecode71TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I SECOND FLOORTonne95817.8495817.8423.78FalseNoneNoneFalseNoneFalse2278548.23520
3805024144495Nonecode72TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I THIRD FLOORTonne96776.0296776.0223.78FalseNoneNoneFalseNoneFalse2301333.75560
3805025144495Nonecode73TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FOURTH FLOORTonne97743.7897743.7823.78FalseNoneNoneFalseNoneFalse2324347.08840
3805026144495Nonecode74TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I HEAD ROOMTonne98721.2298721.223.0FalseNoneNoneFalseNoneFalse296163.660
3805027144495Nonecode75FRAME FOR MAIN DOOR Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.section Sl. No. 12.13.2 Page No. 100, Volume-IIm104580.0104580.00.46FalseNoneNoneFalseNoneFalse48106.80
3805028144495Nonecode76SHUTTER FOR MAIN DOOR Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sl. No. 12.18. Page No. 100, Volume-IISqm6904.86904.811.28FalseNoneNoneFalseNoneFalse77886.1440
3805029144495Nonecode77WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II GROUND FLOORm737.1737.160.0FalseNoneNoneFalseNoneFalse44226.00
3805030144495Nonecode78WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FIRST FLOORm744.47744.4790.0FalseNoneNoneFalseNoneFalse67002.30
3805031144495Nonecode79WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II SECOND FLOORm751.92751.9290.0FalseNoneNoneFalseNoneFalse67672.80
3805032144495Nonecode80WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II THIRD FLOORm759.43759.4390.0FalseNoneNoneFalseNoneFalse68348.70
3805033144495Nonecode81WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FOURTH FLOORm767.03767.0390.0FalseNoneNoneFalseNoneFalse69032.70
3805034144495Nonecode82WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II HEAD ROOMm767.03767.036.0FalseNoneNoneFalseNoneFalse4602.180
3805035144495Nonecode83WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II GROUND FLOORSqm4631.554631.5521.96FalseNoneNoneFalseNoneFalse101708.8380
3805036144495Nonecode84WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FIRST FLOORSqm4677.874677.8728.35FalseNoneNoneFalseNoneFalse132617.61450
3805037144495Nonecode85WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II SECOND FLOORSqm4724.644724.6428.35FalseNoneNoneFalseNoneFalse133943.5440
3805038144495Nonecode86WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II THIRD FLOORSqm4771.894771.8928.35FalseNoneNoneFalseNoneFalse135283.08150
3805039144495Nonecode87WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FOURTH FLOORSqm4819.614819.6128.35FalseNoneNoneFalseNoneFalse136635.94350
3805040144495Nonecode88WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II HEAD ROOMSqm4867.814867.811.89FalseNoneNoneFalseNoneFalse9200.16090
3805041144495Nonecode89UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II Ground floorm246.17246.1762.7FalseNoneNoneFalseNoneFalse15434.8590
3805042144495Nonecode90UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/-0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II First Floorm248.63248.63125.4FalseNoneNoneFalseNoneFalse31178.2020
3805043144495Nonecode91UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II SECOND FLOORm251.12251.12125.4FalseNoneNoneFalseNoneFalse31490.4480
3805044144495Nonecode92UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/-0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II THIRD FLOORm253.63253.63125.4FalseNoneNoneFalseNoneFalse31805.2020
3805045144495Nonecode93UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II FOURTH FLOORm256.17256.17125.4FalseNoneNoneFalseNoneFalse32123.7180
3805046144495Nonecode94UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II Ground floorSqm6432.356432.3517.33FalseNoneNoneFalseNoneFalse111472.62550
3805047144495Nonecode95UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FIRST FLOORSqm6496.676496.6734.65FalseNoneNoneFalseNoneFalse225109.61550
3805048144495Nonecode96UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II SECOND FLOORSqm6561.646561.6434.65FalseNoneNoneFalseNoneFalse227360.8260
3805049144495Nonecode97UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II THIRD FLOORSqm6627.266627.2634.65FalseNoneNoneFalseNoneFalse229634.5590
3805050144495Nonecode98UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FOURTH FLOORSqm6693.536693.5334.65FalseNoneNoneFalseNoneFalse231930.81450
3805051144495Nonecode99HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm GROUND FloorNo566.5566.510.0FalseNoneNoneFalseNoneFalse5665.00
3805052144495Nonecode100HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm First FloorNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3805053144495Nonecode101HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm SECOND FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3805054144495Nonecode102HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm THIRD FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3805055144495Nonecode103HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm FOURTH FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3805056144495Nonecode104HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II GROUND FloorNo386.25386.2518.0FalseNoneNoneFalseNoneFalse6952.50
3805057144495Nonecode105HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II First FloorNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3805058144495Nonecode106HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II SECOND FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3805059144495Nonecode107HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II THIRD FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3805060144495Nonecode108HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II FOURTH FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3805061144495Nonecode109HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II GROUND FloorNo206.0206.018.0FalseNoneNoneFalseNoneFalse3708.00
3805062144495Nonecode110HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II First FloorNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3805063144495Nonecode111HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II SECOND FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3805064144495Nonecode112HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II THIRD FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3805065144495Nonecode113HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II FOURTH FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3805066144495Nonecode114HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II GROUND FloorNo72.172.118.0FalseNoneNoneFalseNoneFalse1297.80
3805067144495Nonecode115HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II First FloorNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3805068144495Nonecode116HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II SECOND FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3805069144495Nonecode117HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II THIRD FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3805070144495Nonecode118HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II FOURTH FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3805071144495Nonecode119HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II GROUND FloorNo103.0103.09.0FalseNoneNoneFalseNoneFalse927.00
3805072144495Nonecode120HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II First FloorNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3805073144495Nonecode121HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II SECOND FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3805074144495Nonecode122HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II THIRD FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3805075144495Nonecode123HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II FOURTH FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3805076144495Nonecode124UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II GROUND FLOORSqm6004.956004.954.32FalseNoneNoneFalseNoneFalse25941.3840
3805077144495Nonecode125UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FIRST FLOORSqm6064.86064.88.28FalseNoneNoneFalseNoneFalse50216.5440
3805078144495Nonecode126UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II SECOND FLOORSqm6125.456125.458.28FalseNoneNoneFalseNoneFalse50718.7260
3805079144495Nonecode127UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II THIRD FLOORSqm6186.76186.78.28FalseNoneNoneFalseNoneFalse51225.8760
3805080144495Nonecode128UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FOURTH FLOORSqm6248.576248.578.28FalseNoneNoneFalseNoneFalse51738.15960
3805081144495Nonecode129GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II GROUND FLOORKgs176.4176.41147.2FalseNoneNoneFalseNoneFalse202366.080
3805082144495Nonecode130GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FIRST FLOORKgs178.16178.161096.2FalseNoneNoneFalseNoneFalse195298.9920
3805083144495Nonecode131GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II SECOND FLOORKgs179.95179.951096.2FalseNoneNoneFalseNoneFalse197261.190
3805084144495Nonecode132GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II THIRD FLOORKgs181.75181.751096.2FalseNoneNoneFalseNoneFalse199234.350
3805085144495Nonecode133GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FOURTH FLOORKgs183.56183.561096.2FalseNoneNoneFalseNoneFalse201218.4720
3805086144495Nonecode134UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II GROUND FLOORSqm7070.77070.754.36FalseNoneNoneFalseNoneFalse384363.2520
3805087144495Nonecode135UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FIRST FLOORSqm7141.417141.4148.6FalseNoneNoneFalseNoneFalse347072.5260
3805088144495Nonecode136UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II SECOND FLOORSqm7212.827212.8248.6FalseNoneNoneFalseNoneFalse350543.0520
3805089144495Nonecode137UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II THIRD FLOORSqm7284.957284.9548.6FalseNoneNoneFalseNoneFalse354048.570
3805090144495Nonecode138UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FOURTH FLOORSqm7357.87357.848.6FalseNoneNoneFalseNoneFalse357589.080
3805091144495Nonecode139UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II HEAD ROOMSqm7431.387431.382.7FalseNoneNoneFalseNoneFalse20064.7260
3805092144495Nonecode140PUTTY ITEM Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ceiling Sl.No 8.51 Page No.50 Volume-IISqm105.0105.02229.18FalseNoneNoneFalseNoneFalse234063.90
3805093144495Nonecode141INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II GROUND FLOORSqm384.3384.3986.25FalseNoneNoneFalseNoneFalse379015.8750
3805094144495Nonecode142INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FIRST FLOORSqm388.5388.51337.84FalseNoneNoneFalseNoneFalse519750.840
3805095144495Nonecode143INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II SECOND FLOORSqm392.39392.391337.84FalseNoneNoneFalseNoneFalse524955.03760
3805096144495Nonecode144INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II THIRD FLOORSqm396.31396.311337.84FalseNoneNoneFalseNoneFalse530199.37040
3805097144495Nonecode145INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FOURTH FLOORSqm400.27400.271337.84FalseNoneNoneFalseNoneFalse535497.21680
3805098144495Nonecode146INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II HEAD ROOMSqm404.27404.27155.51FalseNoneNoneFalseNoneFalse62868.02770
3805099144495Nonecode147WALL PUTTY FOR ABOVE Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51 Page No.50 Volume-IISqm105.0105.06493.13FalseNoneNoneFalseNoneFalse681778.650
3805100144495Nonecode148ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II GROUND FLOORSqm309.75309.75196.72FalseNoneNoneFalseNoneFalse60934.020
3805101144495Nonecode149ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FIRST FLOORSqm312.85312.85289.96FalseNoneNoneFalseNoneFalse90713.9860
3805102144495Nonecode150ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II SECOND FLOORSqm315.98315.98289.96FalseNoneNoneFalseNoneFalse91621.56080
3805103144495Nonecode151ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II THIRD FLOORSqm319.14319.14289.96FalseNoneNoneFalseNoneFalse92537.83440
3805104144495Nonecode152ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FOURTH FLOORSqm322.33322.33289.96FalseNoneNoneFalseNoneFalse93462.80680
3805105144495Nonecode153EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II GROUND FLOORSqm404.25404.25428.4FalseNoneNoneFalseNoneFalse173180.70
3805106144495Nonecode154EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FIRST FLOORSqm408.45408.45428.4FalseNoneNoneFalseNoneFalse174979.980
3805107144495Nonecode155EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II SECOND FLOORSqm412.53412.53428.4FalseNoneNoneFalseNoneFalse176727.8520
3805108144495Nonecode156EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II THIRD FLOORSqm416.66416.66428.4FalseNoneNoneFalseNoneFalse178497.1440
3805109144495Nonecode157EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FOURTH FLOORSqm420.83420.83428.4FalseNoneNoneFalseNoneFalse180283.5720
3805110144495Nonecode158EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II HEAD ROOMSqm425.03425.03167.63FalseNoneNoneFalseNoneFalse71247.77890
3805111144495Nonecode159LATH PALSTER Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sl.No8.16.a, Page No.43 Volume-IISqm1299.91299.9327.48FalseNoneNoneFalseNoneFalse425691.2520
3805112144495Nonecode160FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II GROUND FLOORSqm1319.851319.85160.92FalseNoneNoneFalseNoneFalse212390.2620
3805113144495Nonecode161FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FIRST FLOORSqm1333.051333.05301.47FalseNoneNoneFalseNoneFalse401874.58350
3805114144495Nonecode162FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II SECOND FLOORSqm1346.381346.38301.47FalseNoneNoneFalseNoneFalse405893.17860
3805115144495Nonecode163FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II THIRD FLOORSqm1359.841359.84301.47FalseNoneNoneFalseNoneFalse409950.96480
3805116144495Nonecode164FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FOURTH FLOORSqm1373.41373.4301.47FalseNoneNoneFalseNoneFalse414038.8980
3805117144495Nonecode165GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II GROUND FLOORSqm2994.62994.6317.53FalseNoneNoneFalseNoneFalse950875.3380
3805118144495Nonecode166GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FIRST FLOORSqm3024.553024.5594.2FalseNoneNoneFalseNoneFalse284912.610
3805119144495Nonecode167GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II SECOND FLOORSqm3054.793054.7994.2FalseNoneNoneFalseNoneFalse287761.2180
3805120144495Nonecode168GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II THIRD FLOORSqm3085.343085.3494.2FalseNoneNoneFalseNoneFalse290639.0280
3805121144495Nonecode169GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FOURTH FLOORSqm3116.193116.1994.2FalseNoneNoneFalseNoneFalse293545.0980
3805122144495Nonecode170GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II GROUND FLOORSqm5594.45594.421.34FalseNoneNoneFalseNoneFalse119384.4960
3805123144495Nonecode171GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FIRST FLOORSqm5650.345650.3421.34FalseNoneNoneFalseNoneFalse120578.25560
3805124144495Nonecode172GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II SECOND FLOORSqm5706.855706.8521.34FalseNoneNoneFalseNoneFalse121784.1790
3805125144495Nonecode173GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II THIRD FLOORSqm5763.925763.9221.34FalseNoneNoneFalseNoneFalse123002.05280
3805126144495Nonecode174GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FOURTH FLOORSqm5821.565821.5621.34FalseNoneNoneFalseNoneFalse124232.09040
3805127144495Nonecode175HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi GROUND FLOORm180.0180.046.4FalseNoneNoneFalseNoneFalse8352.00
3805128144495Nonecode176HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FIRST FLOORm181.8181.833.6FalseNoneNoneFalseNoneFalse6108.480
3805129144495Nonecode177HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi SECOND FLOORm183.62183.6233.6FalseNoneNoneFalseNoneFalse6169.6320
3805130144495Nonecode178HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi THIRD FLOORm185.45185.4533.6FalseNoneNoneFalseNoneFalse6231.120
3805131144495Nonecode179HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FOURTH FLOORm187.31187.3133.6FalseNoneNoneFalseNoneFalse6293.6160
3805132144495Nonecode180CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II GROUND FLOORSqm933.45933.4548.0FalseNoneNoneFalseNoneFalse44805.60
3805133144495Nonecode181CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FIRST FLOORSqm942.78942.7874.0FalseNoneNoneFalseNoneFalse69765.720
3805134144495Nonecode182CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II SECOND FLOORSqm952.21952.2174.0FalseNoneNoneFalseNoneFalse70463.540
3805135144495Nonecode183CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II THIRD FLOORSqm961.73961.7374.0FalseNoneNoneFalseNoneFalse71168.020
3805136144495Nonecode184CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FOURTH FLOORSqm971.35971.3574.0FalseNoneNoneFalseNoneFalse71879.90
3805137144495Nonecode185CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II GROUND FLOORSqm1161.31161.3192.78FalseNoneNoneFalseNoneFalse223875.4140
3805138144495Nonecode186CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FIRST FLOORSqm1172.911172.91289.96FalseNoneNoneFalseNoneFalse340096.98360
3805139144495Nonecode187CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II SECOND FLOORSqm1184.641184.64289.96FalseNoneNoneFalseNoneFalse343498.21440
3805140144495Nonecode188CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II THIRD FLOORSqm1196.491196.49289.96FalseNoneNoneFalseNoneFalse346934.24040
3805141144495Nonecode189CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FOURTH FLOORSqm1208.451208.45289.96FalseNoneNoneFalseNoneFalse350402.1620
3805142144495Nonecode190PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR WallsSqm165.9165.9986.25FalseNoneNoneFalseNoneFalse163618.8750
3805143144495Nonecode191PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR CelingSqm165.9165.9434.98FalseNoneNoneFalseNoneFalse72163.1820
3805144144495Nonecode192PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR WallsSqm167.56167.561337.84FalseNoneNoneFalseNoneFalse224168.47040
3805145144495Nonecode193PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR CelingSqm167.56167.56444.8FalseNoneNoneFalseNoneFalse74530.6880
3805146144495Nonecode194PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR WallsSqm169.23169.231337.84FalseNoneNoneFalseNoneFalse226402.66320
3805147144495Nonecode195PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR CelingSqm169.23169.23444.8FalseNoneNoneFalseNoneFalse75273.5040
3805148144495Nonecode196PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR WallsSqm170.93170.931337.84FalseNoneNoneFalseNoneFalse228676.99120
3805149144495Nonecode197PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR CelingSqm170.93170.93444.8FalseNoneNoneFalseNoneFalse76029.6640
3805150144495Nonecode198PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FOURTH FLOOR WallsSqm172.64172.64155.51FalseNoneNoneFalseNoneFalse26847.24640
3805151144495Nonecode199PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM WallsSqm174.36174.36155.51FalseNoneNoneFalseNoneFalse27114.72360
3805152144495Nonecode200PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM CelingSqm174.36174.3615.0FalseNoneNoneFalseNoneFalse2615.40
3805153144495Nonecode201PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Ground floorSqm182.7182.7364.14FalseNoneNoneFalseNoneFalse66528.3780
3805154144495Nonecode202PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II First floorSqm184.53184.53364.14FalseNoneNoneFalseNoneFalse67194.75420
3805155144495Nonecode203PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Second floorSqm186.37186.37364.14FalseNoneNoneFalseNoneFalse67864.77180
3805156144495Nonecode204PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Third floorSqm188.24188.24364.14FalseNoneNoneFalseNoneFalse68545.71360
3805157144495Nonecode205PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II TFourth floorSqm190.12190.12364.14FalseNoneNoneFalseNoneFalse69230.29680
3805158144495Nonecode206PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II HEAD ROOMSqm192.02192.02142.49FalseNoneNoneFalseNoneFalse27360.92980
3805159144495Nonecode207PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Ground floorSqm297.15297.1564.26FalseNoneNoneFalseNoneFalse19094.8590
3805160144495Nonecode208PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II First floorSqm300.12300.1264.26FalseNoneNoneFalseNoneFalse19285.71120
3805161144495Nonecode209PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Second floorSqm303.12303.1264.26FalseNoneNoneFalseNoneFalse19478.49120
3805162144495Nonecode210PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Third floorSqm306.15306.1564.26FalseNoneNoneFalseNoneFalse19673.1990
3805163144495Nonecode211PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II foruth floorSqm309.22309.2264.26FalseNoneNoneFalseNoneFalse19870.47720
3805164144495Nonecode212PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II HEAD ROOMSqm312.31312.3125.14FalseNoneNoneFalseNoneFalse7851.47340
3805165144495Nonecode213SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II GROUND FLOORKg593.25593.25252.0FalseNoneNoneFalseNoneFalse149499.00
3805166144495Nonecode214SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FIRST FLOORKg599.18599.18122.4FalseNoneNoneFalseNoneFalse73339.6320
3805167144495Nonecode215SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II SECOND FLOORKg605.17605.17122.4FalseNoneNoneFalseNoneFalse74072.8080
3805168144495Nonecode216SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II THIRD FLOORKg611.23611.23122.4FalseNoneNoneFalseNoneFalse74814.5520
3805169144495Nonecode217SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FOURTH FLOORKg617.34617.34122.4FalseNoneNoneFalseNoneFalse75562.4160
3805170144495Nonecode218WATER PROOFING Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sl.No 15.1, Page No.149 Volume-IISqm857.85857.85500.0FalseNoneNoneFalseNoneFalse428925.00
3805171144495Nonecode219CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FIRST FLOORSqm2138.852138.8514.6FalseNoneNoneFalseNoneFalse31227.210
3805172144495Nonecode220CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II SECOND FLOORSqm2160.242160.2414.6FalseNoneNoneFalseNoneFalse31539.5040
3805173144495Nonecode221CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II THIRD FLOORSqm2181.842181.8414.6FalseNoneNoneFalseNoneFalse31854.8640
3805174144495Nonecode222CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FOURTH FLOORSqm2203.662203.6614.6FalseNoneNoneFalseNoneFalse32173.4360
3805175144495Nonecode223FLAGGING CONCRETE Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Sl.No 2.1.5, Page No.15 Volume-ICum6156.06156.010.71FalseNoneNoneFalseNoneFalse65930.760
3805176144495Nonecode224NP3 pipes for the Coutyard to Outlet of Water Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 750mm dia Sl.No 20.16, Page No.134 Volume-IIIm3501.753501.7510.0FalseNoneNoneFalseNoneFalse35017.50
3805177144495Nonecode225PLUMBING Providing & fixing Chorinated Poly Venyl Chloride (CPVC) 20 mm dia pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc. (P.No.122, vol-2 I.No.13.32.2 of SR 2023-24 ) 20 mm diam397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3805178144495Nonecode226Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc.for : pipes of SN 4, 75mm dia (P.No.114, I.No.10.2.1, vol 5, of SR 2023-24m227.85227.85150.0FalseNoneNoneFalseNoneFalse34177.50
3805179144495Nonecode227EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7, I.No.9.10, vol 1, of SR 2023-24Cum279.3279.340.0FalseNoneNoneFalseNoneFalse11172.00
3805180144495Nonecode228Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 20 mm nominal bore (P.No.117, I.No.13.15 of SR 2021-22) (vol-2)Nos761.25761.2550.0FalseNoneNoneFalseNoneFalse38062.50
3805181144495Nonecode229Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix tures complete,,including cutting and making good the walls and floors wherever required (P.No.131, I.No.14.2.1, vol 2, of SR 2023-24Nos5079.95079.950.0FalseNoneNoneFalseNoneFalse253995.00
3805182144495Nonecode230Providing and fixing Health faucet of approved make confirming to ISI specifications at suitable place as per direction of engineer-in- charge ( Rate is inclusive of cost of materials and fixtures, labour and conveyance of materials to work spot complete.) (2 in 1 tap system) ( Market Rate) Approved Rate as MDRS Aralihalli GangavathiNos1260.01260.050.0FalseNoneNoneFalseNoneFalse63000.00
3805183144495Nonecode231Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.No.133, I.No.14.7A, vol 2, of SR 2023-24Nos4327.054327.0550.0FalseNoneNoneFalseNoneFalse216352.50
3805184144495Nonecode232Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (P.No.127, I.No.13.59, vol-2 of SR 2023-24)Nos231.0231.0120.0FalseNoneNoneFalseNoneFalse27720.00
3805185144495Nonecode233Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern I.No. 14.5.1 V-IINos9074.19074.125.0FalseNoneNoneFalseNoneFalse226852.50
3805186144495Nonecode234Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (P.No.135, I.No.14.22B, vol-2 of SR 2023-24)Nos5840.15840.138.0FalseNoneNoneFalseNoneFalse221923.80
3805187144495Nonecode235Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. (P.No.119, I.No.13.14, vol-2 of SR 2023-24)Nos888.3888.340.0FalseNoneNoneFalseNoneFalse35532.00
3805188144495Nonecode236Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (P.No.117, I.No.13.2.1, vol 2, of SR 2023-24Nos300.3300.340.0FalseNoneNoneFalseNoneFalse12012.00
3805189144495Nonecode237KSRB13-6.3-: Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification (P.No.41, I.No.2.79.1, vol-5 of SR 2023-24)Nos396.9396.915.0FalseNoneNoneFalseNoneFalse5953.50
3805190144495Nonecode238EX P Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 100 mm dia , having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.9 vol-2 of SR 2023-24 )m2650.22650.2150.0FalseNoneNoneFalseNoneFalse397530.00
3805191144495Nonecode239Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 65 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.7 vol-2 of SR 2023-24 )m1470.01470.0120.0FalseNoneNoneFalseNoneFalse176400.00
3805192144495Nonecode240Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 50.00 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.6 , vil-2 of SR 2023-24)m757.05757.05175.0FalseNoneNoneFalseNoneFalse132483.750
3805193144495Nonecode241Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 40 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.5 , vol-2 of SR 2023-24)m500.85500.85100.0FalseNoneNoneFalseNoneFalse50085.00
3805194144495Nonecode242Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 32 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.4, vol-2 of SR 2023-24 )m390.6390.6150.0FalseNoneNoneFalseNoneFalse58590.00
3805195144495Nonecode243Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 25 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.3 , vol-2 of SR 2023-24 )m310.8310.8120.0FalseNoneNoneFalseNoneFalse37296.00
3805196144495Nonecode244Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-32mm (P.No.117, I.No.13.4.2 , vol-2 of SR 2023-24 )Nos627.9627.920.0FalseNoneNoneFalseNoneFalse12558.00
3805197144495Nonecode245Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-50mm (P.No.117, I.No.13.4.4 , vol-2 of SR 2023-24 )Nos897.75897.7520.0FalseNoneNoneFalseNoneFalse17955.00
3805198144495Nonecode246Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-65mm (P.No.117, SI.No.13.4.5 , vol-2 of SR 2023-24 )Nos1481.551481.5520.0FalseNoneNoneFalseNoneFalse29631.00
3805199144495Nonecode247Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-80mm (P.No.117, I.No.13.4.6 , vol-2 of SR 2023-24 )Nos2180.852180.8510.0FalseNoneNoneFalseNoneFalse21808.50
3805200144495Nonecode248Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 75mm dia.(P.No.114, I.No10.2.1, vol -5 of SR 2023-24)m227.85227.85120.0FalseNoneNoneFalseNoneFalse27342.00
3805201144495Nonecode249Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 110mm dia. (P.No.114, I.No10.2.2, vol -5 of SR 2023-24)m302.4302.4120.0FalseNoneNoneFalseNoneFalse36288.00
3805202144495Nonecode250Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 160mm dia Pipem604.8604.835.0FalseNoneNoneFalseNoneFalse21168.00
3805203144495Nonecode251Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 200mm dia Pipem872.55872.5525.0FalseNoneNoneFalseNoneFalse21813.750
3805204144495Nonecode252Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 250mm dia Pipem1337.71337.725.0FalseNoneNoneFalseNoneFalse33442.50
3805205144495Nonecode253Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m (P.No.10, I.No.1.17.1-(Vol-1) of SR 2023-24)Cum275.1275.112.15FalseNoneNoneFalseNoneFalse3342.4650
3805206144495Nonecode254Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover (P.No.190, I.No. 16.10 of SR 2023-24) (vol-5)Nos4447.84447.85.0FalseNoneNoneFalseNoneFalse22239.00
3805207144495Nonecode255Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (P.No.190, I.No. 16.9 of SR 2023-24) (vol-5)Nos5726.75726.75.0FalseNoneNoneFalseNoneFalse28633.50
3805208144495Nonecode256Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (P.No.191, I.No. 16.10 of SR 2023-24) (vol-5)Nos4447.84447.83.0FalseNoneNoneFalseNoneFalse13343.40
3805209144495Nonecode257Providing and fixing Pressure relief valve suitable for 40 mm dia pipe at 7th floor to reduce pressure due to head , including cost of all accessories ,labour charges etc. complete as directed by engineer in charge. Market Rate Approved rate from MDRS GangavathiNos12600.012600.05.0FalseNoneNoneFalseNoneFalse63000.00
3805210144495Nonecode258Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchNos282.45282.4510.0FalseNoneNoneFalseNoneFalse2824.50
3805211144495Nonecode259Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchNos397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3805212144495Nonecode260Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchNos582.75582.75120.0FalseNoneNoneFalseNoneFalse69930.00
3805213144495Nonecode261Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesNos710.85710.8530.0FalseNoneNoneFalseNoneFalse21325.50
3805214144495Nonecode262Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switchesNos1038.451038.4515.0FalseNoneNoneFalseNoneFalse15576.750
3805215144495Nonecode263Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayNos144.9144.9120.0FalseNoneNoneFalseNoneFalse17388.00
3805216144495Nonecode264Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WayNos166.95166.95500.0FalseNoneNoneFalseNoneFalse83475.00
3805217144495Nonecode265Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayNos185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3805218144495Nonecode266Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayNos231.0231.06.0FalseNoneNoneFalseNoneFalse1386.00
3805219144495Nonecode267Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayNos274.05274.0590.0FalseNoneNoneFalseNoneFalse24664.50
3805220144495Nonecode268Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayNos334.95334.9510.0FalseNoneNoneFalseNoneFalse3349.50
3805221144495Nonecode269Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleNos143.85143.85150.0FalseNoneNoneFalseNoneFalse21577.50
3805222144495Nonecode270Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleNos169.05169.05500.0FalseNoneNoneFalseNoneFalse84525.00
3805223144495Nonecode271Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleNos183.75183.756.0FalseNoneNoneFalseNoneFalse1102.50
3805224144495Nonecode272Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleNos245.7245.76.0FalseNoneNoneFalseNoneFalse1474.20
3805225144495Nonecode273Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleNos298.2298.290.0FalseNoneNoneFalseNoneFalse26838.00
3805226144495Nonecode274Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleNos361.2361.215.0FalseNoneNoneFalseNoneFalse5418.00
3805227144495Nonecode275Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchNos107.1107.1700.0FalseNoneNoneFalseNoneFalse74970.00
3805228144495Nonecode276Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way SwitchNos174.3174.310.0FalseNoneNoneFalseNoneFalse1743.00
3805229144495Nonecode277Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketNos179.55179.55430.0FalseNoneNoneFalseNoneFalse77206.50
3805230144495Nonecode278Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Nos374.85374.85120.0FalseNoneNoneFalseNoneFalse44982.00
3805231144495Nonecode279Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchNos342.3342.35.0FalseNoneNoneFalseNoneFalse1711.50
3805232144495Nonecode280Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketNos247.8247.855.0FalseNoneNoneFalseNoneFalse13629.00
3805233144495Nonecode281Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchNos189.0189.055.0FalseNoneNoneFalseNoneFalse10395.00
3805234144495Nonecode282Supplyin and Fixing Metal Fan Box with Round Hook.Nos122.85122.85120.0FalseNoneNoneFalseNoneFalse14742.00
3805235144495Nonecode283Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20AmpsNos1019.551019.556.0FalseNoneNoneFalseNoneFalse6117.30
3805236144495Nonecode284Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30AmpsNos1785.01785.03.0FalseNoneNoneFalseNoneFalse5355.00
3805237144495Nonecode285Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.33000.0FalseNoneNoneFalseNoneFalse207900.00
3805238144495Nonecode286Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.9878.0FalseNoneNoneFalseNoneFalse71908.20
3805239144495Nonecode287Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thickm108.15108.1550.0FalseNoneNoneFalseNoneFalse5407.50
3805240144495Nonecode288Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.42000.0FalseNoneNoneFalseNoneFalse142800.00
3805241144495Nonecode289Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.951500.0FalseNoneNoneFalseNoneFalse124425.00
3805242144495Nonecode290Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thickm103.95103.9560.0FalseNoneNoneFalseNoneFalse6237.00
3805243144495Nonecode291Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200 x 200 x 65 mmNos365.4365.42.0FalseNoneNoneFalseNoneFalse730.80
3805244144495Nonecode292Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxNos58.858.8250.0FalseNoneNoneFalseNoneFalse14700.00
3805245144495Nonecode293Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxNos64.0564.05100.0FalseNoneNoneFalseNoneFalse6405.00
3805246144495Nonecode294Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 20mmm19.9519.9530.0FalseNoneNoneFalseNoneFalse598.50
3805247144495Nonecode295Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mmm23.123.130.0FalseNoneNoneFalseNoneFalse693.00
3805248144495Nonecode296Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mmm30.4530.4520.0FalseNoneNoneFalseNoneFalse609.00
3805249144495Nonecode297Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 -4C x 6 mm2m344.4344.4500.0FalseNoneNoneFalseNoneFalse172200.00
3805250144495Nonecode298Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm27.327.34000.0FalseNoneNoneFalseNoneFalse109200.00
3805251144495Nonecode299Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm44.144.19500.0FalseNoneNoneFalseNoneFalse418950.00
3805252144495Nonecode300Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm66.1566.151500.0FalseNoneNoneFalseNoneFalse99225.00
3805253144495Nonecode301Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmm96.696.6300.0FalseNoneNoneFalseNoneFalse28980.00
3805254144495Nonecode302Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way TP & NNos6395.556395.5510.0FalseNoneNoneFalseNoneFalse63955.50
3805255144495Nonecode303Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way TP & NNos9171.759171.752.0FalseNoneNoneFalseNoneFalse18343.50
3805256144495Nonecode304Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNos435.75435.75320.0FalseNoneNoneFalseNoneFalse139440.00
3805257144495Nonecode305Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNos775.95775.9530.0FalseNoneNoneFalseNoneFalse23278.50
3805258144495Nonecode306Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps DPNos1113.01113.04.0FalseNoneNoneFalseNoneFalse4452.00
3805259144495Nonecode307Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNNos3196.23196.210.0FalseNoneNoneFalseNoneFalse31962.00
3805260144495Nonecode308Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 poleNos4490.854490.8530.0FalseNoneNoneFalseNoneFalse134725.50
3805261144495Nonecode309Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 poleNos5822.255822.2510.0FalseNoneNoneFalseNoneFalse58222.50
3805262144495Nonecode3101.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 25 sqmmKm188836.2188836.20.2FalseNoneNoneFalseNoneFalse37767.240
3805263144495Nonecode3111.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km391875.75391875.750.2FalseNoneNoneFalseNoneFalse78375.150
3805264144495Nonecode312Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm32695.9532695.950.2FalseNoneNoneFalseNoneFalse6539.190
3805265144495Nonecode313GI Pipe, 100 mm Dia for drain crossing, cable raising etc.,m1296.751296.7512.0FalseNoneNoneFalseNoneFalse15561.00
3805266144495Nonecode314Brass cable gland 32mm diaNos99.7599.7520.0FalseNoneNoneFalseNoneFalse1995.00
3805267144495Nonecode315Brass cable gland 45mm diaNos206.85206.8530.0FalseNoneNoneFalseNoneFalse6205.50
3805268144495Nonecode316Aluminium end terminal lug 10 sqmmNos2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3805269144495Nonecode317Aluminium end terminal lug 16 sqmmNos2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3805270144495Nonecode318Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 GmNos147.0147.020.0FalseNoneNoneFalseNoneFalse2940.00
3805271144495Nonecode319Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Nos4468.84468.88.0FalseNoneNoneFalseNoneFalse35750.40
3805272144495Nonecode320Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripm86.186.150.0FalseNoneNoneFalseNoneFalse4305.00
3805273144495Nonecode321Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI stripm134.4134.420.0FalseNoneNoneFalseNoneFalse2688.00
3805274144495Nonecode322Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm GI Plate.Nos918.75918.754.0FalseNoneNoneFalseNoneFalse3675.00
3805275144495Nonecode323Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper stripm598.5598.550.0FalseNoneNoneFalseNoneFalse29925.00
3805276144495Nonecode324Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. strip 25x6mm Copper stripm1155.01155.050.0FalseNoneNoneFalseNoneFalse57750.00
3805277144495Nonecode325Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plateNos7792.057792.052.0FalseNoneNoneFalseNoneFalse15584.10
3805278144495Nonecode326Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 10-12WNos1332.451332.455.0FalseNoneNoneFalseNoneFalse6662.250
3805279144495Nonecode327Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 15-18WNos1754.551754.5525.0FalseNoneNoneFalseNoneFalse43863.750
3805280144495Nonecode328Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9/10 wNos578.55578.5535.0FalseNoneNoneFalseNoneFalse20249.250
3805281144495Nonecode329Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 WNos1332.451332.45300.0FalseNoneNoneFalseNoneFalse399735.00
3805282144495Nonecode330Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 36wattNos4780.654780.6520.0FalseNoneNoneFalseNoneFalse95613.00
3805283144495Nonecode331Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNos6291.66291.66.0FalseNoneNoneFalseNoneFalse37749.60
3805284144495Nonecode332Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm)Nos3117.453117.4540.0FalseNoneNoneFalseNoneFalse124698.00
3805285144495Nonecode333Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 56" Sweep 5 Star (1400 mm)Nos4991.74991.7120.0FalseNoneNoneFalseNoneFalse599004.00
3805286144495Nonecode334Supplying & Fixing of 70-150 Watts lamp holder 2 PinNos66.1566.1520.0FalseNoneNoneFalseNoneFalse1323.00
3805287144495Nonecode335Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersNos128.1128.130.0FalseNoneNoneFalseNoneFalse3843.00
3805288144495Nonecode336Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Nos330.75330.75100.0FalseNoneNoneFalseNoneFalse33075.00
3805289144495Nonecode337Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Nos742.35742.3540.0FalseNoneNoneFalseNoneFalse29694.00
3805290144495Nonecode338Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.Nos514.5514.5350.0FalseNoneNoneFalseNoneFalse180075.00
3805291144495Nonecode339Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthNos1534.051534.056.0FalseNoneNoneFalseNoneFalse9204.30
3805292144495Nonecode340Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNos1359.751359.756.0FalseNoneNoneFalseNoneFalse8158.50
3805293144495Nonecode341Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Nos170.1170.16.0FalseNoneNoneFalseNoneFalse1020.60
3805294144495Nonecode342MAIN LT PANEL Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSqm0.450.45150000.0FalseNoneNoneFalseNoneFalse67500.00
3805295144495Nonecode343Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Stripsm2588.252588.255.0FalseNoneNoneFalseNoneFalse12941.250
3805296144495Nonecode344Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm320.25320.2520.0FalseNoneNoneFalseNoneFalse6405.00
3805297144495Nonecode345Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm793.8793.820.0FalseNoneNoneFalseNoneFalse15876.00
3805298144495Nonecode346Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNos435.75435.755.0FalseNoneNoneFalseNoneFalse2178.750
3805299144495Nonecode347Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNos775.95775.954.0FalseNoneNoneFalseNoneFalse3103.80
3805300144495Nonecode348Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A TPNNos1802.851802.8512.0FalseNoneNoneFalseNoneFalse21634.20
3805301144495Nonecode349Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNos9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3805302144495Nonecode350Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CNos540.75540.7510.0FalseNoneNoneFalseNoneFalse5407.50
3805303144495Nonecode351Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape WoundNos590.1590.110.0FalseNoneNoneFalseNoneFalse5901.00
3805304144495Nonecode352Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V, 125 ANos77527.877527.81.0FalseNoneNoneFalseNoneFalse77527.80
3805305144495Nonecode353EXTERNAL STREET LIGHTING Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32Nos16275.016275.04.0FalseNoneNoneFalseNoneFalse65100.00
3805306144495Nonecode354Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNos6291.66291.64.0FalseNoneNoneFalseNoneFalse25166.40
3805307144495Nonecode355Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNos1359.751359.754.0FalseNoneNoneFalseNoneFalse5439.00
3805308144495Nonecode356Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr HeightNos4755.44755.44.0FalseNoneNoneFalseNoneFalse19021.60
3805309144495Nonecode357Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Nos170.1170.14.0FalseNoneNoneFalseNoneFalse680.40
3805310144495Nonecode358Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNos775.95775.953.0FalseNoneNoneFalseNoneFalse2327.850
3805311144495Nonecode359Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting.Nos2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3805312144495Nonecode360Supplying and fixing of solar Lux level street light control switch single phase including suitable capacity contactor- 8KWNos12621.012621.01.0FalseNoneNoneFalseNoneFalse12621.00
3805313144495Nonecode361Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.3350.0FalseNoneNoneFalseNoneFalse24255.00
3805314144495Nonecode362Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.935.0FalseNoneNoneFalseNoneFalse2866.50
3805315144495Nonecode363Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.445.0FalseNoneNoneFalseNoneFalse3213.00
3805316144495Nonecode364Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.9545.0FalseNoneNoneFalseNoneFalse3732.750
3805317144495Nonecode365IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.Nos20200.020200.015.0FalseNoneNoneFalseNoneFalse303000.00
3805318144495Nonecode366IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.Nos21700.021700.03.0FalseNoneNoneFalseNoneFalse65100.00
3805319144495Nonecode367Supplying and drawing UTP-CAT 6E LAN cablem41.841.8800.0FalseNoneNoneFalseNoneFalse33440.00
3805320144495Nonecode368Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as requiredNos14500.014500.01.0FalseNoneNoneFalseNoneFalse14500.00
3805321144495Nonecode369Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as requiredNos40250.040250.01.0FalseNoneNoneFalseNoneFalse40250.00
3805322144495Nonecode370Supply and Installation of I/OsNos125.0125.050.0FalseNoneNoneFalseNoneFalse6250.00
3805323144495Nonecode371Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as requiredNos225.0225.010.0FalseNoneNoneFalseNoneFalse2250.00
3805324144495Nonecode372Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as requiredNos285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3805325144495Nonecode373Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as requiredNos60000.060000.01.0FalseNoneNoneFalseNoneFalse60000.00
3805326144495Nonecode374Design,supplying,erectingtestingandcommissioningof-Passenger/Bed-cum passengerhospitalliftwithspeedof1mtrpersecond,variablevoltagevariablefrequencydrive,withorwithoutmachineroomfortheavailablewellsize,operatingat415V3phase50cyclesACsupply,powdercoated/StainlessSteelcarentrancedoorsenclosureswithsuitablecolourvinylflooring,LEDcarillumination,emergencylight,intercomandfanasdesiredbytheuser,centralopening/sideopeningdoorwithorwithoutattendantoperation,7segmentdisplaybuttons,callregisterindicator,firemandrive,SShandrailsinsidecar,fulllengthinfraredcurtainincardoor,automaticrescuedevicewithbatteries,voiceannouncinginregional/internationallanguages,Braillebuttonswithoneyearwarrantyandmaintenancewithnecessaryscaffoldingandminorcivilworkslikefixingofguiderail,counterweightetc.,ThetotalproductandservicesshalladheretoIS14665/2016(withlatestamendments)part/section1to5withregardstogeneralguidelinesoffiresafetyrateddoors,MRLLbeams,pressureswitch,manualchangeoverfordoorsduringemergency,ARDof10timeswithsufficientbatterybackupandstandarddimensionsofchaircaranddooropeningsforallsizesandcapacitiesofliftsincludingfitnesscertificateanddulyobservingallothersafetynormsprescribedandadheretoCPWDspecifications,PCBNorms,NationalElectricityCode(NEC),NBC-2016,IECandKarnatakaStateLifts,EscalatorsandPassengersConveyersAct 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. With Out Machine Room-PC FinishJob1666957.371666957.371.0FalseNoneNoneFalseNoneFalse1666957.370
3805327144495Nonecode375Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles)Nos21974.421974.42.0FalseNoneNoneFalseNoneFalse43948.80
3805328144495Nonecode376Erection DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WLNos5640.65640.62.0FalseNoneNoneFalseNoneFalse11281.20
3805329144495Nonecode377Supply& erection of 11 kV, 45 KN Polymeric InsulatorNos195.3195.312.0FalseNoneNoneFalseNoneFalse2343.60
3805330144495Nonecode378Supply of Guy Set Complete with No. 15 Strain InsulatorNos1228.51228.53.0FalseNoneNoneFalseNoneFalse3685.50
3805331144495Nonecode379Erection of Guy Set Complete with No. 15 Strain InsulatorNos622.65622.653.0FalseNoneNoneFalseNoneFalse1867.950
3805332144495Nonecode380Supply of Spiral Earth ElectrodeNos250.95250.953.0FalseNoneNoneFalseNoneFalse752.850
3805333144495Nonecode381Erection of Spiral Earth ElectrodeNos97.6597.653.0FalseNoneNoneFalseNoneFalse292.950
3805334144495Nonecode382Supply& fixing of Guy concreting with Boulders, Mud and SandNos262.5262.53.0FalseNoneNoneFalseNoneFalse787.50
3805335144495Nonecode383Supply of Caution/Danger BoardNos157.5157.52.0FalseNoneNoneFalseNoneFalse315.00
3805336144495Nonecode384Fixing of Caution/Danger BoardNos84.084.02.0FalseNoneNoneFalseNoneFalse168.00
3805337144495Nonecode385Supply of Anti Climbing Device (12 Mtr GI Barbed WireNos93.4593.453.0FalseNoneNoneFalseNoneFalse280.350
3805338144495Nonecode386Erection of Anti Climbing Device (12 Mtr GI Barbed WireNos44.144.13.0FalseNoneNoneFalseNoneFalse132.30
3805339144495Nonecode387Supply and fixing of 11 kV, 400 Amps Double Break GOSNos22323.022323.02.0FalseNoneNoneFalseNoneFalse44646.00
3805340144495Nonecode388Fixing of 11 kV, 400 Amps Double Break GOSNos1274.71274.72.0FalseNoneNoneFalseNoneFalse2549.40
3805341144495Nonecode389Supply of H-Frame for mounting GOSNos4548.64548.62.0FalseNoneNoneFalseNoneFalse9097.20
3805342144495Nonecode390fixing of H-Frame for mounting GOSNos339.15339.152.0FalseNoneNoneFalseNoneFalse678.30
3805343144495Nonecode391Supply of DOLO Cut OutNos6165.66165.62.0FalseNoneNoneFalseNoneFalse12331.20
3805344144495Nonecode392Erection of DOLO Cut OutNos248.85248.852.0FalseNoneNoneFalseNoneFalse497.70
3805345144495Nonecode39311KV EXTENSION Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785Nos7429.87429.82.0FalseNoneNoneFalseNoneFalse14859.60
3805346144495Nonecode394Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785Nos1829.11829.12.0FalseNoneNoneFalseNoneFalse3658.20
3805347144495Nonecode395Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNos678.3678.32.0FalseNoneNoneFalseNoneFalse1356.60
3805348144495Nonecode396Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNos285.6285.62.0FalseNoneNoneFalseNoneFalse571.20
3805349144495Nonecode397Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)Nos215.25215.256.0FalseNoneNoneFalseNoneFalse1291.50
3805350144495Nonecode398Supply and fixing of 11 kV, 45 KN Polymeric InsulatorNos195.3195.36.0FalseNoneNoneFalseNoneFalse1171.80
3805351144495Nonecode399Supply of Guy Set Complete with No. 15 Strain InsulatorNos1228.51228.52.0FalseNoneNoneFalseNoneFalse2457.00
3805352144495Nonecode400Erection of Guy Set Complete with No. 15 Strain InsulatorNos622.65622.652.0FalseNoneNoneFalseNoneFalse1245.30
3805353144495Nonecode401Supply of Rabbit ACSR ConductorKm48545.748545.71.0FalseNoneNoneFalseNoneFalse48545.70
3805354144495Nonecode402Erection of Rabbit ACSR ConductorKm4579.054579.051.0FalseNoneNoneFalseNoneFalse4579.050
3805355144495Nonecode403Supply and fixing of PG Clamps for Rabbit ConductorNos107.1107.115.0FalseNoneNoneFalseNoneFalse1606.50
3805356144495Nonecode404Supply of Spiral Earth ElectrodeNos250.95250.952.0FalseNoneNoneFalseNoneFalse501.90
3805357144495Nonecode405Erection of Spiral Earth ElectrodeNos97.6597.652.0FalseNoneNoneFalseNoneFalse195.30
3805358144495Nonecode406Supply of EG Stirrups with GI wire lacingNos289.8289.82.0FalseNoneNoneFalseNoneFalse579.60
3805359144495Nonecode407Erection of EG Stirrups with GI wire lacingNos168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3805360144495Nonecode408Guy concreting with Boulders, Mud and SandNos262.5262.52.0FalseNoneNoneFalseNoneFalse525.00
3805361144495Nonecode409Supply of Caution/Danger BoardNos157.5157.53.0FalseNoneNoneFalseNoneFalse472.50
3805362144495Nonecode410Erection of Caution/Danger BoardNos84.084.03.0FalseNoneNoneFalseNoneFalse252.00
3805363144495Nonecode411Supply of Anti Climbing Device (12 Mtr GI Barbed WireNos93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3805364144495Nonecode412Erection of Anti Climbing Device (12 Mtr GI Barbed WireNos44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3805365144495Nonecode413Erection of 3 Phase, 11kV/433V, 63 kVA BEE 4/5 Star Rated Distribution Transformer Centre Using DPTS Using PSCC Pole - 9 Mtr Long, 300 Kg WL supplying of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)Nos29051.429051.41.0FalseNoneNoneFalseNoneFalse29051.40
3805366144495Nonecode414supplying & fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)Nos215.25215.253.0FalseNoneNoneFalseNoneFalse645.750
3805367144495Nonecode415supplying & fixing of 11 kV, 45 KN Polymeric InsulatorNos195.3195.33.0FalseNoneNoneFalseNoneFalse585.90
3805368144495Nonecode416Supplying of Guy Set Complete with No. 15 Strain InsulatorNos1228.51228.54.0FalseNoneNoneFalseNoneFalse4914.00
3805369144495Nonecode417Supplying of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNos191672.25191672.251.0FalseNoneNoneFalseNoneFalse191672.250
3805370144495Nonecode418Supplying of Earthing materials pipe type for grounding (Single Electrode with accessories)Nos1815.451815.453.0FalseNoneNoneFalseNoneFalse5446.350
3805371144495Nonecode419Supplying of Caution/Danger BoardNos157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3805372144495Nonecode420supplying of Anti Climbing Device (12 Mtr GI Barbed Wire)Nos93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3805373144495Nonecode421Supplying & fixing of GI Wire 8 SWGKg78.7978.795.0FalseNoneNoneFalseNoneFalse393.950
3805374144495Nonecode422Supplying & fixing of Guy wire 7/10 SWGKg81.0981.0910.0FalseNoneNoneFalseNoneFalse810.90
3805375144495Nonecode423Supplying & fixing of 11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA, Polymeric type with ground disconnectorNos4989.64989.61.0FalseNoneNoneFalseNoneFalse4989.60
3805376144495Nonecode424a) Supplying of LT Protection Kit for 63 kVANos2124.152124.152.0FalseNoneNoneFalseNoneFalse4248.30
3805377144495Nonecode425b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmmm116.85116.8540.0FalseNoneNoneFalseNoneFalse4674.00
3805378144495Nonecode426b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT ii) Heavy Duty Long Barrel Copper Lug - 95 SqmmNos135.45135.454.0FalseNoneNoneFalseNoneFalse541.80
3805379144495Nonecode427b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iii) PG Clamp - Rabbit to 95 SqmmNos147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
3805380144495Nonecode428b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iv) Spacer for DTC WiringNos44.144.18.0FalseNoneNoneFalseNoneFalse352.80
3805381144495Nonecode429b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)Nos277.2277.22.0FalseNoneNoneFalseNoneFalse554.40
3805382144495Nonecode430c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)Nos5905.25905.21.0FalseNoneNoneFalseNoneFalse5905.20
3805383144495Nonecode431d) LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNos3565.83565.81.0FalseNoneNoneFalseNoneFalse3565.80
3805384144495Nonecode432Supplying of 11 kV, Solid Core Type HG Fuse UnitNos1122.451122.451.0FalseNoneNoneFalseNoneFalse1122.450
3805385144495Nonecode433suppying of 11 kV, 200 Amps, Single Break GOSNos9922.59922.51.0FalseNoneNoneFalseNoneFalse9922.50
3805386144495Nonecode434Fixing of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)Nos7332.157332.151.0FalseNoneNoneFalseNoneFalse7332.150
3805387144495Nonecode435Fixing of Guy Set Complete with No. 15 Strain InsulatorNos622.65622.654.0FalseNoneNoneFalseNoneFalse2490.60
3805388144495Nonecode436Fixing of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNos1252.651252.651.0FalseNoneNoneFalseNoneFalse1252.650
3805389144495Nonecode437Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories)Nos996.45996.453.0FalseNoneNoneFalseNoneFalse2989.350
3805390144495Nonecode438Fixing of Caution/Danger BoardNos84.084.01.0FalseNoneNoneFalseNoneFalse84.00
3805391144495Nonecode439Fixing Anti Climbing Device (12 Mtr GI Barbed Wire)Nos44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3805392144495Nonecode440Fixing of Guy concreting with Boulders, Mud and SandNos262.5262.54.0FalseNoneNoneFalseNoneFalse1050.00
3805393144495Nonecode441a) Fixing of LT Protection Kit for 63 kVANos373.8373.82.0FalseNoneNoneFalseNoneFalse747.60
3805394144495Nonecode442b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmm ii) Heavy Duty Long Barrel Copper Lug - 95 Sqmm iii) PG Clamp - Rabbit to 95 Sqmm iv) Spacer for DTC Wiring v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)Nos996.45996.451.0FalseNoneNoneFalseNoneFalse996.450
3805395144495Nonecode443c) fixing of LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)Nos908.25908.251.0FalseNoneNoneFalseNoneFalse908.250
3805396144495Nonecode444d) fixing of LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNos504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3805397144495Nonecode445fixing of 11 kV, Solid Core Type HG Fuse UnitNos248.85248.851.0FalseNoneNoneFalseNoneFalse248.850
3805398144495Nonecode446Fixing of 11 kV, 200 Amps, Single Break GOSNos1159.21159.21.0FalseNoneNoneFalseNoneFalse1159.20
3805399144495Nonecode447SUMP TANK EARTH WORK Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m Page No. 8,Sl. No.1.14Cum107.1107.156.0FalseNoneNoneFalseNoneFalse5997.60
3805400144495Nonecode448PCC BED Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.2, Page No.15Cum5947.25947.24.0FalseNoneNoneFalseNoneFalse23788.80
3805401144495Nonecode449EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7Cum279.3279.33.69FalseNoneNoneFalseNoneFalse1030.6170
3805402144495Nonecode450Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24Cum7185.027185.024.85FalseNoneNoneFalseNoneFalse34847.3470
3805403144495Nonecode451RCC Work Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-ICum7903.677903.678.09FalseNoneNoneFalseNoneFalse63940.69030
3805404144495Nonecode452Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum10777.7310777.734.85FalseNoneNoneFalseNoneFalse52271.99050
3805405144495Nonecode453PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42 Volume-IISqm404.25404.2588.0FalseNoneNoneFalseNoneFalse35574.00
3805406144495Nonecode454Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. Sl. No. 8.12, Page No.43 Volume-IISqm67.267.288.0FalseNoneNoneFalseNoneFalse5913.60
3805407144495Nonecode455KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification (Page No. 75, Sl. No. 11.45)Nos283.5283.510.0FalseNoneNoneFalseNoneFalse2835.00
3805408144495Nonecode456STEEL Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Sl. No. 2.11 a, Page No.18 Volume-IKg82961.5582961.553.84FalseNoneNoneFalseNoneFalse318572.3520
3805409144495Nonecode457Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete V0L-V SL No 12.4 V-5 PG:140Nos5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3805410144495Nonecode458Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50mtr 12.2.1m324.45324.4550.0FalseNoneNoneFalseNoneFalse16222.50
3805411144495Nonecode459Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50 to 100 mtr 12.2.2m406.35406.3550.0FalseNoneNoneFalseNoneFalse20317.50
3805412144495Nonecode460Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 100 to 150 mtr 12.2.3m432.6432.650.0FalseNoneNoneFalseNoneFalse21630.00
3805413144495Nonecode461Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 150 to 200mtr 12.2.4m501.9501.950.0FalseNoneNoneFalseNoneFalse25095.00
3805414144495Nonecode462Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 VOL-V SL No 10.1.8 pg 113 V-5 140 mm dia casing pipesm613.2613.2180.0FalseNoneNoneFalseNoneFalse110376.00
3805415144495Nonecode463Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (VOL-V) SL No 13.15.7 V-6 PG: 152Nos42850.542850.51.0FalseNoneNoneFalseNoneFalse42850.50
3805416144495Nonecode464Supplyinganddrawing3coreflatPVCsheathedsubmersiblepumpcablemanufacturedwithelectrolyticgradecopperwithflexiblecopperwithlowresistanceconductorconfirmingto13:8130 1984andvirgingradePVCinsulationandpowdercoatingextrudedPVCsheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 mm2 SL No: 2.6.2 V-6 PG: 7m176.4176.4330.0FalseNoneNoneFalseNoneFalse58212.00
3805417144495Nonecode465Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valves VOL-V ) 50 mm Size = 1No SL No: 11.15.6 pg 133 V-5Nos1772.41772.41.0FalseNoneNoneFalseNoneFalse1772.40
3805418144495Nonecode466Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (IT NO 28.1 PG NO 162 ) VOL-V 50 mm Size = 1No SL No: 13.25.1 pg 154 V-5Nos1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3805419144495Nonecode467Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter (6 to 15 HP pumps) IT NO 30.2 & PG NO-162 VOL-V SL No: 13.24.3 pg 155 V-5Nos18375.018375.01.0FalseNoneNoneFalseNoneFalse18375.00
3805420144495Nonecode468Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ( IT NO 38 & PG NO-163 ,VOL-V) SL No: 13.32 pg 156 V-5Nos6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3805421144495Nonecode469Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 7.5 HP, size 100x100 Head 195M, Discharge 1200 LPM SL No:13.40.6 PG: 157 V-5Nos32046.032046.01.0FalseNoneNoneFalseNoneFalse32046.00
3805422144495Nonecode470Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. All items are of ISI standards. 2. After commissioning of plant necessary testing to be done for the 3. Satisfaction of the Engineer in charge. 4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. Page No. 251 ,Sl. No-22.2.1 B. VOL-5 STP ( 25 KLD)Nos1359750.01359750.01.0FalseNoneNoneFalseNoneFalse1359750.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17240463410000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17240463410000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17240463410000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17240463410000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17240463410000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17240463460000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17240463490000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17240463620000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17240463670000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17240463710000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17240463740000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17240463770000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17240463810000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17240463850000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17240463890000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17240463940000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17240463960000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17240464000000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17240464040000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17240464080000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724159989000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone