createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723897847469
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1060000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-09-2024 16:00:00
tenderQueryClose02-09-2024 16:00:00
technicalBidOpen21-09-2024 16:00:00
publishedDate20-08-2024 19:03:49
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate03-09-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1723897847487
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT263
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Ravoor Village, Chittapura Taluk, Kalaburagi District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Ravoor Village, Chittapura Taluk, Kalaburagi District
categoryWORKS
categoryTextWorks
ecv70462187.97
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount70462188.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/321/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17238978470000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Ravoor Village, Chittapura Taluk, Kalaburagi District70462187.97
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3798997144101Nonecode01JUNGLE CLEARANCE Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of light jungle SR 2023-24 Page No. 9,Sl. No.2.5 A. VOL-3 ii a Rate per 100SqmSqm412.65412.657.02FalseNoneNoneFalseNoneFalse2896.8030
3798998144101Nonecode02Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Page No. 5,Sl. No.1.1 . VOL-1Sqm95.5595.55702.0FalseNoneNoneFalseNoneFalse67076.10
3798999144101Nonecode03EARTH WORK FOR BUILDING Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m SR 2023-24 Page No. 8,Sl. No.1.14.1 A. VOL-1Cum107.1107.11496.62FalseNoneNoneFalseNoneFalse160288.0020
3799000144101Nonecode04Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In ordinary/soft rock without blasting SR 2023-24 (P.No.8, Vol-1, SI.No.1.15.1 ) soft rock without blasting 20%Cum381.15381.15370.1347FalseNoneNoneFalseNoneFalse141076.8409050
3799001144101Nonecode05CC 1:3:6 For Bed ConcreteProviding and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarseaggregates SR 2023-24 Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4584.91FalseNoneNoneFalseNoneFalse533952.28950
3799002144101Nonecode06ANTI TERMITE TREATMENT Providing and injecting chemical emulsion for Preconstructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications Sl.No 4.1/ Page No. 5- VOL-2Sqm123.9123.9525.0FalseNoneNoneFalseNoneFalse65047.50
3799003144101Nonecode07SOIL TREATMENT Treatment of soil with Chloropyriphos/Lindane E.C. 20% with 1% concentration under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: Sl.No 4.3/ Page No. 5- VOL-2Sqm365.4365.4192.08FalseNoneNoneFalseNoneFalse70186.0320
3799004144101Nonecode08SOILING Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. Sl.No 1.23/ Page No. 11- VOL-1Cum2816.12816.1192.08FalseNoneNoneFalseNoneFalse540916.4880
3799005144101Nonecode09RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1Cum7185.027185.02440.73FalseNoneNoneFalseNoneFalse3166653.86460
3799006144101Nonecode10RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1 PEDESTALCum7318.087318.0812.04FalseNoneNoneFalseNoneFalse88109.68320
3799007144101Nonecode11RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I upto plinthCum12214.7612214.7619.12FalseNoneNoneFalseNoneFalse233546.21120
3799008144101Nonecode12RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum12214.7612214.7627.22FalseNoneNoneFalseNoneFalse332485.76720
3799009144101Nonecode13RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum12336.912336.927.22FalseNoneNoneFalseNoneFalse335810.4180
3799010144101Nonecode14RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum12460.2712460.2727.22FalseNoneNoneFalseNoneFalse339168.54940
3799011144101Nonecode15RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum12584.8712584.8727.22FalseNoneNoneFalseNoneFalse342560.16140
3799012144101Nonecode16RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum12710.7212710.7227.22FalseNoneNoneFalseNoneFalse345985.79840
3799013144101Nonecode17RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12837.8312837.831.73FalseNoneNoneFalseNoneFalse22209.44590
3799014144101Nonecode18RCC COLUMN(DUMMY COLUMNS) Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 ) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Page 15, Sl. No.2.1.4, Volume-ICum11097.3511097.355.76FalseNoneNoneFalseNoneFalse63920.7360
3799015144101Nonecode19PCC M15 FOR DPC Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Page 15, Sl. No.2.1.4, Volume-ICum6527.856527.851.54FalseNoneNoneFalseNoneFalse10052.8890
3799016144101Nonecode20EARTH REFILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.31313.98FalseNoneNoneFalseNoneFalse366994.6140
3799017144101Nonecode21EARTH FILLING UPTO FLOORING PCC Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.3556.79FalseNoneNoneFalseNoneFalse155511.4470
3799018144101Nonecode22Balance Soil have to brought from Outside Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SL.No 1.8, Page No.7 Volume-ICum497.7497.7306.76FalseNoneNoneFalseNoneFalse152674.4520
3799019144101Nonecode23Flooring Bed Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4543.51FalseNoneNoneFalseNoneFalse273610.45950
3799020144101Nonecode24RCC M25 FOR PLINTH BEAM Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.---- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.4.3 Page No.17 VOL-1Cum9979.29979.276.05FalseNoneNoneFalseNoneFalse758918.160
3799021144101Nonecode25CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II GROUND FLOORSqm1375.51375.5292.77FalseNoneNoneFalseNoneFalse402705.1350
3799022144101Nonecode26CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FIRST FLOORSqm1389.261389.26264.95FalseNoneNoneFalseNoneFalse368084.4370
3799023144101Nonecode27CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II SECOND FLOORSqm1403.151403.15264.95FalseNoneNoneFalseNoneFalse371764.59250
3799024144101Nonecode28CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II THIRD FLOORSqm1417.181417.18264.95FalseNoneNoneFalseNoneFalse375481.8410
3799025144101Nonecode29CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FOURTH FLOORSqm1431.351431.35264.95FalseNoneNoneFalseNoneFalse379236.18250
3799026144101Nonecode30CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II GROUND FLOORSqm1292.551292.55302.94FalseNoneNoneFalseNoneFalse391565.0970
3799027144101Nonecode31CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FIRST FLOORSqm1305.481305.48486.89FalseNoneNoneFalseNoneFalse635625.15720
3799028144101Nonecode32CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II SECOND FLOORSqm1318.531318.53486.89FalseNoneNoneFalseNoneFalse641979.07170
3799029144101Nonecode33CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II THIRD FLOORSqm1331.721331.72486.89FalseNoneNoneFalseNoneFalse648401.15080
3799030144101Nonecode34CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FOURTH FLOORSqm1345.031345.03486.89FalseNoneNoneFalseNoneFalse654881.65670
3799031144101Nonecode35CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II HEAD ROOM DOORSqm1358.481358.48159.94FalseNoneNoneFalseNoneFalse217275.29120
3799032144101Nonecode36CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II GROUND FLOORSqm1159.21159.248.62FalseNoneNoneFalseNoneFalse56360.3040
3799033144101Nonecode37CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FIRST FLOORSqm1170.791170.7997.23FalseNoneNoneFalseNoneFalse113835.91170
3799034144101Nonecode38CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II SECOND FLOORSqm1182.51182.597.23FalseNoneNoneFalseNoneFalse114974.4750
3799035144101Nonecode39CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II THIRD FLOORSqm1194.321194.3297.23FalseNoneNoneFalseNoneFalse116123.73360
3799036144101Nonecode40CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FOURTH FLOORSqm1206.271206.2797.23FalseNoneNoneFalseNoneFalse117285.63210
3799037144101Nonecode41RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.247.73FalseNoneNoneFalseNoneFalse88865.93520
3799038144101Nonecode42RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.211.08FalseNoneNoneFalseNoneFalse128652.0960
3799039144101Nonecode43RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3111.08FalseNoneNoneFalseNoneFalse129938.59480
3799040144101Nonecode44RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5911.08FalseNoneNoneFalseNoneFalse131238.05720
3799041144101Nonecode45RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0311.08FalseNoneNoneFalseNoneFalse132550.37240
3799042144101Nonecode46RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOM DOORCum12082.6612082.660.98FalseNoneNoneFalseNoneFalse11841.00680
3799043144101Nonecode47CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I GROUND FLOORCum9465.389465.383.75FalseNoneNoneFalseNoneFalse35495.1750
3799044144101Nonecode48CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FIRST FLOORCum9560.049560.045.82FalseNoneNoneFalseNoneFalse55639.43280
3799045144101Nonecode49CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I SECOND FLOORCum9655.649655.645.82FalseNoneNoneFalseNoneFalse56195.82480
3799046144101Nonecode50CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I THIRD FLOORCum9752.199752.195.82FalseNoneNoneFalseNoneFalse56757.74580
3799047144101Nonecode51CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FOURTH FLOORCum9849.719849.715.82FalseNoneNoneFalseNoneFalse57325.31220
3799048144101Nonecode52CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I HEAD ROOM DOORCum9948.219948.210.49FalseNoneNoneFalseNoneFalse4874.62290
3799049144101Nonecode53RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.2441.57FalseNoneNoneFalseNoneFalse477898.69680
3799050144101Nonecode54RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.248.13FalseNoneNoneFalseNoneFalse558847.0560
3799051144101Nonecode55RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3148.13FalseNoneNoneFalseNoneFalse564435.43030
3799052144101Nonecode56RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5948.13FalseNoneNoneFalseNoneFalse570080.11670
3799053144101Nonecode57RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0348.13FalseNoneNoneFalseNoneFalse575780.63390
3799054144101Nonecode58RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12082.6612082.662.32FalseNoneNoneFalseNoneFalse28031.77120
3799055144101Nonecode59RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I Ground floorCum10777.7310777.7380.25FalseNoneNoneFalseNoneFalse864912.83250
3799056144101Nonecode60RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.578.0FalseNoneNoneFalseNoneFalse849069.00
3799057144101Nonecode61RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.3678.0FalseNoneNoneFalseNoneFalse857560.080
3799058144101Nonecode62RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.378.0FalseNoneNoneFalseNoneFalse866135.40
3799059144101Nonecode63RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.3478.0FalseNoneNoneFalseNoneFalse874796.520
3799060144101Nonecode64RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.59.9FalseNoneNoneFalseNoneFalse112142.250
3799061144101Nonecode65RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum10777.7310777.734.16FalseNoneNoneFalseNoneFalse44835.35680
3799062144101Nonecode66RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.54.16FalseNoneNoneFalseNoneFalse45283.680
3799063144101Nonecode67RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.364.16FalseNoneNoneFalseNoneFalse45736.53760
3799064144101Nonecode68RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.34.16FalseNoneNoneFalseNoneFalse46193.8880
3799065144101Nonecode69RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.344.16FalseNoneNoneFalseNoneFalse46655.81440
3799066144101Nonecode70RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.54.16FalseNoneNoneFalseNoneFalse47122.40
3799067144101Nonecode71TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I GROUND FLOORTonne93929.8593929.8561.74FalseNoneNoneFalseNoneFalse5799228.9390
3799068144101Nonecode72TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FIRST FLOORTonne94869.1594869.1524.65FalseNoneNoneFalseNoneFalse2338524.54750
3799069144101Nonecode73TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I SECOND FLOORTonne95817.8495817.8424.65FalseNoneNoneFalseNoneFalse2361909.7560
3799070144101Nonecode74TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I THIRD FLOORTonne96776.0296776.0224.65FalseNoneNoneFalseNoneFalse2385528.8930
3799071144101Nonecode75TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FOURTH FLOORTonne97743.7897743.7824.65FalseNoneNoneFalseNoneFalse2409384.1770
3799072144101Nonecode76TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I HEAD ROOMTonne98721.2298721.222.81FalseNoneNoneFalseNoneFalse277406.62820
3799073144101Nonecode77FRAME FOR MAIN DOOR Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.section Sl. No. 12.13.2 Page No. 100, Volume-IIm104580.0104580.00.46FalseNoneNoneFalseNoneFalse48106.80
3799074144101Nonecode78SHUTTER FOR MAIN DOOR Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sl. No. 12.18. Page No. 100, Volume-IISqm6904.86904.811.28FalseNoneNoneFalseNoneFalse77886.1440
3799075144101Nonecode79WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II GROUND FLOORm737.1737.160.0FalseNoneNoneFalseNoneFalse44226.00
3799076144101Nonecode80WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FIRST FLOORm744.47744.4790.0FalseNoneNoneFalseNoneFalse67002.30
3799077144101Nonecode81WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II SECOND FLOORm751.92751.9290.0FalseNoneNoneFalseNoneFalse67672.80
3799078144101Nonecode82WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II THIRD FLOORm759.43759.4390.0FalseNoneNoneFalseNoneFalse68348.70
3799079144101Nonecode83WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FOURTH FLOORm767.03767.0390.0FalseNoneNoneFalseNoneFalse69032.70
3799080144101Nonecode84WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II HEAD ROOMm767.03767.036.0FalseNoneNoneFalseNoneFalse4602.180
3799081144101Nonecode85WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II GROUND FLOORSqm4631.554631.5521.96FalseNoneNoneFalseNoneFalse101708.8380
3799082144101Nonecode86WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FIRST FLOORSqm4677.874677.8728.35FalseNoneNoneFalseNoneFalse132617.61450
3799083144101Nonecode87WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II SECOND FLOORSqm4724.644724.6428.35FalseNoneNoneFalseNoneFalse133943.5440
3799084144101Nonecode88WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II THIRD FLOORSqm4771.894771.8928.35FalseNoneNoneFalseNoneFalse135283.08150
3799085144101Nonecode89WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FOURTH FLOORSqm4819.614819.6128.35FalseNoneNoneFalseNoneFalse136635.94350
3799086144101Nonecode90WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II HEAD ROOMSqm4867.814867.811.89FalseNoneNoneFalseNoneFalse9200.16090
3799087144101Nonecode91HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm GROUND FloorNo566.5566.510.0FalseNoneNoneFalseNoneFalse5665.00
3799088144101Nonecode92HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm First FloorNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3799089144101Nonecode93HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm SECOND FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3799090144101Nonecode94HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm THIRD FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3799091144101Nonecode95HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm FOURTH FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3799092144101Nonecode96HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II GROUND FloorNo386.25386.2518.0FalseNoneNoneFalseNoneFalse6952.50
3799093144101Nonecode97HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II First FloorNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3799094144101Nonecode98HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II SECOND FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3799095144101Nonecode99HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II THIRD FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3799096144101Nonecode100HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II FOURTH FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3799097144101Nonecode101HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II GROUND FloorNo206.0206.018.0FalseNoneNoneFalseNoneFalse3708.00
3799098144101Nonecode102HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II First FloorNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3799099144101Nonecode103HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II SECOND FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3799100144101Nonecode104HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II THIRD FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3799101144101Nonecode105HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II FOURTH FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3799102144101Nonecode106HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II GROUND FloorNo72.172.118.0FalseNoneNoneFalseNoneFalse1297.80
3799103144101Nonecode107HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II First FloorNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3799104144101Nonecode108HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II SECOND FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3799105144101Nonecode109HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II THIRD FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3799106144101Nonecode110HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II FOURTH FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3799107144101Nonecode111HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II GROUND FloorNo103.0103.09.0FalseNoneNoneFalseNoneFalse927.00
3799108144101Nonecode112HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II First FloorNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3799109144101Nonecode113HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II SECOND FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3799110144101Nonecode114HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II THIRD FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3799111144101Nonecode115HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II FOURTH FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3799112144101Nonecode116UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II Ground floorm246.17246.1762.7FalseNoneNoneFalseNoneFalse15434.8590
3799113144101Nonecode117UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/-0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II First Floorm248.63248.63125.4FalseNoneNoneFalseNoneFalse31178.2020
3799114144101Nonecode118UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II SECOND FLOORm251.12251.12125.4FalseNoneNoneFalseNoneFalse31490.4480
3799115144101Nonecode119UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II THIRD FLOORm253.63253.63125.4FalseNoneNoneFalseNoneFalse31805.2020
3799116144101Nonecode120UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance+/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II FOURTH FLOORm256.17256.17125.4FalseNoneNoneFalseNoneFalse32123.7180
3799117144101Nonecode121UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II Ground floorSqm6432.356432.3517.33FalseNoneNoneFalseNoneFalse111472.62550
3799118144101Nonecode122UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FIRST FLOORSqm6496.676496.6734.65FalseNoneNoneFalseNoneFalse225109.61550
3799119144101Nonecode123UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II SECOND FLOORSqm6561.646561.6434.65FalseNoneNoneFalseNoneFalse227360.8260
3799120144101Nonecode124UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II THIRD FLOORSqm6627.266627.2634.65FalseNoneNoneFalseNoneFalse229634.5590
3799121144101Nonecode125UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FOURTH FLOORSqm6693.536693.5334.65FalseNoneNoneFalseNoneFalse231930.81450
3799122144101Nonecode126UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II GROUND FLOORSqm6004.956004.954.32FalseNoneNoneFalseNoneFalse25941.3840
3799123144101Nonecode127UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FIRST FLOORSqm6064.86064.88.28FalseNoneNoneFalseNoneFalse50216.5440
3799124144101Nonecode128UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II SECOND FLOORSqm6125.456125.458.28FalseNoneNoneFalseNoneFalse50718.7260
3799125144101Nonecode129UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II THIRD FLOORSqm6186.76186.78.28FalseNoneNoneFalseNoneFalse51225.8760
3799126144101Nonecode130UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FOURTH FLOORSqm6248.576248.578.28FalseNoneNoneFalseNoneFalse51738.15960
3799127144101Nonecode131GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II GROUND FLOORKg176.4176.41147.2FalseNoneNoneFalseNoneFalse202366.080
3799128144101Nonecode132GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FIRST FLOORKg178.16178.161096.2FalseNoneNoneFalseNoneFalse195298.9920
3799129144101Nonecode133GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II SECOND FLOORKg179.95179.951096.2FalseNoneNoneFalseNoneFalse197261.190
3799130144101Nonecode134GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II THIRD FLOORKg181.75181.751096.2FalseNoneNoneFalseNoneFalse199234.350
3799131144101Nonecode135GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FOURTH FLOORKg183.56183.561096.2FalseNoneNoneFalseNoneFalse201218.4720
3799132144101Nonecode136UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II GROUND FLOORSqm7070.77070.754.36FalseNoneNoneFalseNoneFalse384363.2520
3799133144101Nonecode137UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FIRST FLOORSqm7141.417141.4148.6FalseNoneNoneFalseNoneFalse347072.5260
3799134144101Nonecode138UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II SECOND FLOORSqm7212.827212.8248.6FalseNoneNoneFalseNoneFalse350543.0520
3799135144101Nonecode139UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II THIRD FLOORSqm7284.957284.9548.6FalseNoneNoneFalseNoneFalse354048.570
3799136144101Nonecode140UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FOURTH FLOORSqm7357.87357.848.6FalseNoneNoneFalseNoneFalse357589.080
3799137144101Nonecode141UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II HEAD ROOMSqm7431.387431.382.7FalseNoneNoneFalseNoneFalse20064.7260
3799138144101Nonecode142PUTTY ITEM Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ceiling Sl.No 8.51 Page No.50 Volume-IISqm105.0105.02229.18FalseNoneNoneFalseNoneFalse234063.90
3799139144101Nonecode143INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II GROUND FLOORSqm384.3384.3986.25FalseNoneNoneFalseNoneFalse379015.8750
3799140144101Nonecode144INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FIRST FLOORSqm388.5388.51337.84FalseNoneNoneFalseNoneFalse519750.840
3799141144101Nonecode145INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II SECOND FLOORSqm392.39392.391337.84FalseNoneNoneFalseNoneFalse524955.03760
3799142144101Nonecode146INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II THIRD FLOORSqm396.31396.311337.84FalseNoneNoneFalseNoneFalse530199.37040
3799143144101Nonecode147INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FOURTH FLOORSqm400.27400.271337.84FalseNoneNoneFalseNoneFalse535497.21680
3799144144101Nonecode148INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II HEAD ROOMSqm404.27404.27155.51FalseNoneNoneFalseNoneFalse62868.02770
3799145144101Nonecode149WALL PUTTY FOR ABOVE Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51 Page No.50 Volume-IISqm105.0105.06493.13FalseNoneNoneFalseNoneFalse681778.650
3799146144101Nonecode150ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II GROUND FLOORSqm309.75309.75196.72FalseNoneNoneFalseNoneFalse60934.020
3799147144101Nonecode151ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FIRST FLOORSqm312.85312.85289.96FalseNoneNoneFalseNoneFalse90713.9860
3799148144101Nonecode152ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II SECOND FLOORSqm315.98315.98289.96FalseNoneNoneFalseNoneFalse91621.56080
3799149144101Nonecode153ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II THIRD FLOORSqm319.14319.14289.96FalseNoneNoneFalseNoneFalse92537.83440
3799150144101Nonecode154ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FOURTH FLOORSqm322.33322.33289.96FalseNoneNoneFalseNoneFalse93462.80680
3799151144101Nonecode155EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II GROUND FLOORSqm404.25404.25428.4FalseNoneNoneFalseNoneFalse173180.70
3799152144101Nonecode156EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FIRST FLOORSqm408.45408.45428.4FalseNoneNoneFalseNoneFalse174979.980
3799153144101Nonecode157EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II SECOND FLOORSqm412.53412.53428.4FalseNoneNoneFalseNoneFalse176727.8520
3799154144101Nonecode158EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II THIRD FLOORSqm416.66416.66428.4FalseNoneNoneFalseNoneFalse178497.1440
3799155144101Nonecode159EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FOURTH FLOORSqm420.83420.83428.4FalseNoneNoneFalseNoneFalse180283.5720
3799156144101Nonecode160EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II HEAD ROOMSqm425.03425.03167.63FalseNoneNoneFalseNoneFalse71247.77890
3799157144101Nonecode161LATH PALSTER Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sl.No8.16.a, Page No.43 Volume-IISqm1299.91299.9327.48FalseNoneNoneFalseNoneFalse425691.2520
3799158144101Nonecode162FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II GROUND FLOORSqm1319.851319.85160.92FalseNoneNoneFalseNoneFalse212390.2620
3799159144101Nonecode163FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FIRST FLOORSqm1333.051333.05301.47FalseNoneNoneFalseNoneFalse401874.58350
3799160144101Nonecode164FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II SECOND FLOORSqm1346.381346.38301.47FalseNoneNoneFalseNoneFalse405893.17860
3799161144101Nonecode165FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II THIRD FLOORSqm1359.841359.84301.47FalseNoneNoneFalseNoneFalse409950.96480
3799162144101Nonecode166FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FOURTH FLOORSqm1373.41373.4301.47FalseNoneNoneFalseNoneFalse414038.8980
3799163144101Nonecode167GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II GROUND FLOORSqm2994.62994.6317.53FalseNoneNoneFalseNoneFalse950875.3380
3799164144101Nonecode168GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FIRST FLOORSqm3024.553024.5594.2FalseNoneNoneFalseNoneFalse284912.610
3799165144101Nonecode169GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II SECOND FLOORSqm3054.793054.7994.2FalseNoneNoneFalseNoneFalse287761.2180
3799166144101Nonecode170GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II THIRD FLOORSqm3085.343085.3494.2FalseNoneNoneFalseNoneFalse290639.0280
3799167144101Nonecode171GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FOURTH FLOORSqm3116.193116.1994.2FalseNoneNoneFalseNoneFalse293545.0980
3799168144101Nonecode172GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II GROUND FLOORSqm5594.45594.421.34FalseNoneNoneFalseNoneFalse119384.4960
3799169144101Nonecode173GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FIRST FLOORSqm5650.345650.3421.34FalseNoneNoneFalseNoneFalse120578.25560
3799170144101Nonecode174GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II SECOND FLOORSqm5706.855706.8521.34FalseNoneNoneFalseNoneFalse121784.1790
3799171144101Nonecode175GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II THIRD FLOORSqm5763.925763.9221.34FalseNoneNoneFalseNoneFalse123002.05280
3799172144101Nonecode176GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FOURTH FLOORSqm5821.565821.5621.34FalseNoneNoneFalseNoneFalse124232.09040
3799173144101Nonecode177HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi GROUND FLOORm180.0180.046.4FalseNoneNoneFalseNoneFalse8352.00
3799174144101Nonecode178HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FIRST FLOORm181.8181.833.6FalseNoneNoneFalseNoneFalse6108.480
3799175144101Nonecode179HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi SECOND FLOORm183.62183.6233.6FalseNoneNoneFalseNoneFalse6169.6320
3799176144101Nonecode180HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi THIRD FLOORm185.45185.4533.6FalseNoneNoneFalseNoneFalse6231.120
3799177144101Nonecode181HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FOURTH FLOORm187.31187.3133.6FalseNoneNoneFalseNoneFalse6293.6160
3799178144101Nonecode182CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II GROUND FLOORSqm933.45933.4548.0FalseNoneNoneFalseNoneFalse44805.60
3799179144101Nonecode183CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FIRST FLOORSqm942.78942.7874.0FalseNoneNoneFalseNoneFalse69765.720
3799180144101Nonecode184CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II SECOND FLOORSqm952.21952.2174.0FalseNoneNoneFalseNoneFalse70463.540
3799181144101Nonecode185CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II THIRD FLOORSqm961.73961.7374.0FalseNoneNoneFalseNoneFalse71168.020
3799182144101Nonecode186CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FOURTH FLOORSqm971.35971.3574.0FalseNoneNoneFalseNoneFalse71879.90
3799183144101Nonecode187CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II GROUND FLOORSqm1161.31161.3192.78FalseNoneNoneFalseNoneFalse223875.4140
3799184144101Nonecode188CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FIRST FLOORSqm1172.911172.91289.96FalseNoneNoneFalseNoneFalse340096.98360
3799185144101Nonecode189CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II SECOND FLOORSqm1184.641184.64289.96FalseNoneNoneFalseNoneFalse343498.21440
3799186144101Nonecode190CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II THIRD FLOORSqm1196.491196.49289.96FalseNoneNoneFalseNoneFalse346934.24040
3799187144101Nonecode191CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FOURTH FLOORSqm1208.451208.45289.96FalseNoneNoneFalseNoneFalse350402.1620
3799188144101Nonecode192PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR WallsSqm165.9165.9986.25FalseNoneNoneFalseNoneFalse163618.8750
3799189144101Nonecode193PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR CelingSqm165.9165.9434.98FalseNoneNoneFalseNoneFalse72163.1820
3799190144101Nonecode194PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR WallsSqm167.56167.561337.84FalseNoneNoneFalseNoneFalse224168.47040
3799191144101Nonecode195PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR CelingSqm167.56167.56444.8FalseNoneNoneFalseNoneFalse74530.6880
3799192144101Nonecode196PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR WallsSqm169.23169.231337.84FalseNoneNoneFalseNoneFalse226402.66320
3799193144101Nonecode197PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR CelingSqm169.23169.23444.8FalseNoneNoneFalseNoneFalse75273.5040
3799194144101Nonecode198PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR WallsSqm170.93170.931337.84FalseNoneNoneFalseNoneFalse228676.99120
3799195144101Nonecode199PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR CelingSqm170.93170.93444.8FalseNoneNoneFalseNoneFalse76029.6640
3799196144101Nonecode200PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FOURTH FLOOR WallsSqm172.64172.64155.51FalseNoneNoneFalseNoneFalse26847.24640
3799197144101Nonecode201PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM WallsSqm174.36174.36155.51FalseNoneNoneFalseNoneFalse27114.72360
3799198144101Nonecode202PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM CelingSqm174.36174.3615.0FalseNoneNoneFalseNoneFalse2615.40
3799199144101Nonecode203PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Ground floorSqm182.7182.7364.14FalseNoneNoneFalseNoneFalse66528.3780
3799200144101Nonecode204PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II First floorSqm184.53184.53364.14FalseNoneNoneFalseNoneFalse67194.75420
3799201144101Nonecode205PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Second floorSqm186.37186.37364.14FalseNoneNoneFalseNoneFalse67864.77180
3799202144101Nonecode206PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Third floorSqm188.24188.24364.14FalseNoneNoneFalseNoneFalse68545.71360
3799203144101Nonecode207PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II TFourth floorSqm190.12190.12364.14FalseNoneNoneFalseNoneFalse69230.29680
3799204144101Nonecode208PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II HEAD ROOMSqm192.02192.02142.49FalseNoneNoneFalseNoneFalse27360.92980
3799205144101Nonecode209PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Ground floorSqm297.15297.1564.26FalseNoneNoneFalseNoneFalse19094.8590
3799206144101Nonecode210PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II First floorSqm300.12300.1264.26FalseNoneNoneFalseNoneFalse19285.71120
3799207144101Nonecode211PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Second floorSqm303.12303.1264.26FalseNoneNoneFalseNoneFalse19478.49120
3799208144101Nonecode212PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Third floorSqm306.15306.1564.26FalseNoneNoneFalseNoneFalse19673.1990
3799209144101Nonecode213PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II foruth floorSqm309.22309.2264.26FalseNoneNoneFalseNoneFalse19870.47720
3799210144101Nonecode214PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II HEAD ROOMSqm312.31312.3125.14FalseNoneNoneFalseNoneFalse7851.47340
3799211144101Nonecode215SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II GROUND FLOORKg593.25593.25252.0FalseNoneNoneFalseNoneFalse149499.00
3799212144101Nonecode216SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FIRST FLOORKg599.18599.18122.4FalseNoneNoneFalseNoneFalse73339.6320
3799213144101Nonecode217SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II SECOND FLOORKg605.17605.17122.4FalseNoneNoneFalseNoneFalse74072.8080
3799214144101Nonecode218SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II THIRD FLOORKg611.23611.23122.4FalseNoneNoneFalseNoneFalse74814.5520
3799215144101Nonecode219SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FOURTH FLOORKg617.34617.34122.4FalseNoneNoneFalseNoneFalse75562.4160
3799216144101Nonecode220WATER PROOFING Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sl.No 15.1, Page No.149 Volume-IISqm857.85857.85500.0FalseNoneNoneFalseNoneFalse428925.00
3799217144101Nonecode221CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FIRST FLOORSqm2138.852138.8514.6FalseNoneNoneFalseNoneFalse31227.210
3799218144101Nonecode222CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II SECOND FLOORSqm2160.242160.2414.6FalseNoneNoneFalseNoneFalse31539.5040
3799219144101Nonecode223CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II THIRD FLOORSqm2181.842181.8414.6FalseNoneNoneFalseNoneFalse31854.8640
3799220144101Nonecode224CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FOURTH FLOORSqm2203.662203.6614.6FalseNoneNoneFalseNoneFalse32173.4360
3799221144101Nonecode225FLAGGING CONCRETE Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Sl.No 2.1.5, Page No.15 Volume-ICum6156.06156.010.71FalseNoneNoneFalseNoneFalse65930.760
3799222144101Nonecode226NP3 pipes for the Coutyard to Outlet of Water Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 750mm dia Sl.No 20.16, Page No.134 Volume-IIIm3501.753501.7510.0FalseNoneNoneFalseNoneFalse35017.50
3799223144101Nonecode227PLUMBING Providing & fixing Chorinated Poly Venyl Chloride (CPVC) 20 mm dia pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc. (P.No.122, vol-2 I.No.13.32.2 of SR 2023-24 ) 20 mm diam397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3799224144101Nonecode228Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc.for : pipes of SN 4, 75mm dia (P.No.114, I.No.10.2.1, vol 5, of SR 2023-24m227.85227.85150.0FalseNoneNoneFalseNoneFalse34177.50
3799225144101Nonecode229EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7, I.No.9.10, vol 1, of SR 2023-24Cum279.3279.340.0FalseNoneNoneFalseNoneFalse11172.00
3799226144101Nonecode230Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 20 mm nominal bore (P.No.117, I.No.13.15 of SR 2021-22) (vol-2)No761.25761.2550.0FalseNoneNoneFalseNoneFalse38062.50
3799227144101Nonecode231Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix tures complete,,including cutting and making good the walls and floors wherever required (P.No.131, I.No.14.2.1, vol 2, of SR 2023-24No5079.95079.950.0FalseNoneNoneFalseNoneFalse253995.00
3799228144101Nonecode232Providing and fixing Health faucet of approved make confirming to ISI specifications at suitable place as per direction of engineer-in- charge ( Rate is inclusive of cost of materials and fixtures, labour and conveyance of materials to work spot complete.) (2 in 1 tap system) ( Market Rate) Approved Rate as MDRS Aralihalli GangavathiNo1260.01260.050.0FalseNoneNoneFalseNoneFalse63000.00
3799229144101Nonecode233Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.No.133, I.No.14.7A, vol 2, of SR 2023-24No4327.054327.0550.0FalseNoneNoneFalseNoneFalse216352.50
3799230144101Nonecode234Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (P.No.127, I.No.13.59, vol-2 of SR 2023-24)No231.0231.0120.0FalseNoneNoneFalseNoneFalse27720.00
3799231144101Nonecode235Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern I.No. 14.5.1 V-IINo9074.19074.125.0FalseNoneNoneFalseNoneFalse226852.50
3799232144101Nonecode236Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (P.No.135, I.No.14.22B, vol-2 of SR 2023-24)No5840.15840.138.0FalseNoneNoneFalseNoneFalse221923.80
3799233144101Nonecode237Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. (P.No.119, I.No.13.14, vol-2 of SR 2023-24)No888.3888.340.0FalseNoneNoneFalseNoneFalse35532.00
3799234144101Nonecode238Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (P.No.117, I.No.13.2.1, vol 2, of SR 2023-24No300.3300.340.0FalseNoneNoneFalseNoneFalse12012.00
3799235144101Nonecode239KSRB13-6.3-: Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification (P.No.41, I.No.2.79.1, vol-5 of SR 2023-24)No396.9396.915.0FalseNoneNoneFalseNoneFalse5953.50
3799236144101Nonecode240EX P Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 100 mm dia , having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.9 vol-2 of SR 2023-24 )m2650.22650.2150.0FalseNoneNoneFalseNoneFalse397530.00
3799237144101Nonecode241Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 65 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.7 vol-2 of SR 2023-24 )m1470.01470.0120.0FalseNoneNoneFalseNoneFalse176400.00
3799238144101Nonecode242Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 50.00 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.6 , vil-2 of SR 2023-24)m757.05757.05175.0FalseNoneNoneFalseNoneFalse132483.750
3799239144101Nonecode243Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 40 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.5 , vol-2 of SR 2023-24)m500.85500.85100.0FalseNoneNoneFalseNoneFalse50085.00
3799240144101Nonecode244Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 32 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.4, vol-2 of SR 2023-24 )m390.6390.6150.0FalseNoneNoneFalseNoneFalse58590.00
3799241144101Nonecode245Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 25 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.3 , vol-2 of SR 2023-24 )m310.8310.8120.0FalseNoneNoneFalseNoneFalse37296.00
3799242144101Nonecode246Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-32mm (P.No.117, I.No.13.4.2 , vol-2 of SR 2023-24 )No627.9627.920.0FalseNoneNoneFalseNoneFalse12558.00
3799243144101Nonecode247Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-50mm (P.No.117, I.No.13.4.4 , vol-2 of SR 2023-24 )No897.75897.7520.0FalseNoneNoneFalseNoneFalse17955.00
3799244144101Nonecode248Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-65mm (P.No.117, SI.No.13.4.5 , vol-2 of SR 2023-24 )No1481.551481.5520.0FalseNoneNoneFalseNoneFalse29631.00
3799245144101Nonecode249Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-80mm (P.No.117, I.No.13.4.6 , vol-2 of SR 2023-24 )No2180.852180.8510.0FalseNoneNoneFalseNoneFalse21808.50
3799246144101Nonecode250Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 75mm dia.(P.No.114, I.No10.2.1, vol -5 of SR 2023-24)m227.85227.85120.0FalseNoneNoneFalseNoneFalse27342.00
3799247144101Nonecode251Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 110mm dia. (P.No.114, I.No10.2.2, vol -5 of SR 2023-24)m302.4302.4120.0FalseNoneNoneFalseNoneFalse36288.00
3799248144101Nonecode252Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 160mm dia Pipem604.8604.835.0FalseNoneNoneFalseNoneFalse21168.00
3799249144101Nonecode253Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 200mm dia Pipem872.55872.5525.0FalseNoneNoneFalseNoneFalse21813.750
3799250144101Nonecode254Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 250mm dia Pipem1337.71337.725.0FalseNoneNoneFalseNoneFalse33442.50
3799251144101Nonecode255Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m (P.No.10, I.No.1.17.1-(Vol-1) of SR 2023-24)Cum275.1275.112.15FalseNoneNoneFalseNoneFalse3342.4650
3799252144101Nonecode256Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover (P.No.190, I.No. 16.10 of SR 2023-24) (vol-5)No4447.84447.85.0FalseNoneNoneFalseNoneFalse22239.00
3799253144101Nonecode257Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (P.No.190, I.No. 16.9 of SR 2023-24) (vol-5)No5726.75726.75.0FalseNoneNoneFalseNoneFalse28633.50
3799254144101Nonecode258Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (P.No.191, I.No. 16.10 of SR 2023-24) (vol-5)No4447.84447.83.0FalseNoneNoneFalseNoneFalse13343.40
3799255144101Nonecode259Providing and fixing Pressure relief valve suitable for 40 mm dia pipe at 7th floor to reduce pressure due to head , including cost of all accessories ,labour charges etc. complete as directed by engineer in charge. Market Rate Approved rate from MDRS GangavathiNo12600.012600.05.0FalseNoneNoneFalseNoneFalse63000.00
3799256144101Nonecode260Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchNo282.45282.4510.0FalseNoneNoneFalseNoneFalse2824.50
3799257144101Nonecode261Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchNo397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3799258144101Nonecode262Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchNo582.75582.75120.0FalseNoneNoneFalseNoneFalse69930.00
3799259144101Nonecode263Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesNo710.85710.8530.0FalseNoneNoneFalseNoneFalse21325.50
3799260144101Nonecode264Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switchesNo1038.451038.4515.0FalseNoneNoneFalseNoneFalse15576.750
3799261144101Nonecode265Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayNo144.9144.9120.0FalseNoneNoneFalseNoneFalse17388.00
3799262144101Nonecode266Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WayNo166.95166.95500.0FalseNoneNoneFalseNoneFalse83475.00
3799263144101Nonecode267Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3799264144101Nonecode268Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayNo231.0231.06.0FalseNoneNoneFalseNoneFalse1386.00
3799265144101Nonecode269Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayNo274.05274.0590.0FalseNoneNoneFalseNoneFalse24664.50
3799266144101Nonecode270Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayNo334.95334.9510.0FalseNoneNoneFalseNoneFalse3349.50
3799267144101Nonecode271Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleNo143.85143.85150.0FalseNoneNoneFalseNoneFalse21577.50
3799268144101Nonecode272Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleNo169.05169.05500.0FalseNoneNoneFalseNoneFalse84525.00
3799269144101Nonecode273Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleNo183.75183.756.0FalseNoneNoneFalseNoneFalse1102.50
3799270144101Nonecode274Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleNo245.7245.76.0FalseNoneNoneFalseNoneFalse1474.20
3799271144101Nonecode275Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleNo298.2298.290.0FalseNoneNoneFalseNoneFalse26838.00
3799272144101Nonecode276Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleNo361.2361.215.0FalseNoneNoneFalseNoneFalse5418.00
3799273144101Nonecode277Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchNo107.1107.1700.0FalseNoneNoneFalseNoneFalse74970.00
3799274144101Nonecode278Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way SwitchNo174.3174.310.0FalseNoneNoneFalseNoneFalse1743.00
3799275144101Nonecode279Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketNo179.55179.55430.0FalseNoneNoneFalseNoneFalse77206.50
3799276144101Nonecode280Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.No374.85374.85120.0FalseNoneNoneFalseNoneFalse44982.00
3799277144101Nonecode281Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchNo342.3342.35.0FalseNoneNoneFalseNoneFalse1711.50
3799278144101Nonecode282Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketNo247.8247.855.0FalseNoneNoneFalseNoneFalse13629.00
3799279144101Nonecode283Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchNo189.0189.055.0FalseNoneNoneFalseNoneFalse10395.00
3799280144101Nonecode284Supplyin and Fixing Metal Fan Box with Round Hook.No122.85122.85120.0FalseNoneNoneFalseNoneFalse14742.00
3799281144101Nonecode285Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20AmpsNo1019.551019.556.0FalseNoneNoneFalseNoneFalse6117.30
3799282144101Nonecode286Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30AmpsNo1785.01785.03.0FalseNoneNoneFalseNoneFalse5355.00
3799283144101Nonecode287Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.33000.0FalseNoneNoneFalseNoneFalse207900.00
3799284144101Nonecode288Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.9878.0FalseNoneNoneFalseNoneFalse71908.20
3799285144101Nonecode289Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thickm108.15108.1550.0FalseNoneNoneFalseNoneFalse5407.50
3799286144101Nonecode290Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.42000.0FalseNoneNoneFalseNoneFalse142800.00
3799287144101Nonecode291Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.951500.0FalseNoneNoneFalseNoneFalse124425.00
3799288144101Nonecode292Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thickm103.95103.9560.0FalseNoneNoneFalseNoneFalse6237.00
3799289144101Nonecode293Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200 x 200 x 65 mmNo365.4365.42.0FalseNoneNoneFalseNoneFalse730.80
3799290144101Nonecode294Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxNo58.858.8250.0FalseNoneNoneFalseNoneFalse14700.00
3799291144101Nonecode295Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxNo64.0564.05100.0FalseNoneNoneFalseNoneFalse6405.00
3799292144101Nonecode296Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 20mmm19.9519.9530.0FalseNoneNoneFalseNoneFalse598.50
3799293144101Nonecode297Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mmm23.123.130.0FalseNoneNoneFalseNoneFalse693.00
3799294144101Nonecode298Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mmm30.4530.4520.0FalseNoneNoneFalseNoneFalse609.00
3799295144101Nonecode299Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 -4C x 6 mm2m344.4344.4500.0FalseNoneNoneFalseNoneFalse172200.00
3799296144101Nonecode300Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm27.327.34000.0FalseNoneNoneFalseNoneFalse109200.00
3799297144101Nonecode301Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm44.144.19500.0FalseNoneNoneFalseNoneFalse418950.00
3799298144101Nonecode302Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm66.1566.151500.0FalseNoneNoneFalseNoneFalse99225.00
3799299144101Nonecode303Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmm96.696.6300.0FalseNoneNoneFalseNoneFalse28980.00
3799300144101Nonecode304Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way TP & NNo6395.556395.5510.0FalseNoneNoneFalseNoneFalse63955.50
3799301144101Nonecode305Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way TP & NNo9171.759171.752.0FalseNoneNoneFalseNoneFalse18343.50
3799302144101Nonecode306Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo435.75435.75320.0FalseNoneNoneFalseNoneFalse139440.00
3799303144101Nonecode307Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNo775.95775.9530.0FalseNoneNoneFalseNoneFalse23278.50
3799304144101Nonecode308Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps DPNo1113.01113.04.0FalseNoneNoneFalseNoneFalse4452.00
3799305144101Nonecode309Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNNo3196.23196.210.0FalseNoneNoneFalseNoneFalse31962.00
3799306144101Nonecode310Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 poleNo4490.854490.8530.0FalseNoneNoneFalseNoneFalse134725.50
3799307144101Nonecode311Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 poleNo5822.255822.2510.0FalseNoneNoneFalseNoneFalse58222.50
3799308144101Nonecode3121.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 25 sqmmKm188836.2188836.20.2FalseNoneNoneFalseNoneFalse37767.240
3799309144101Nonecode3131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km391875.75391875.750.2FalseNoneNoneFalseNoneFalse78375.150
3799310144101Nonecode314Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm32695.9532695.950.2FalseNoneNoneFalseNoneFalse6539.190
3799311144101Nonecode315GI Pipe, 100 mm Dia for drain crossing, cable raising etc.,m1296.751296.7512.0FalseNoneNoneFalseNoneFalse15561.00
3799312144101Nonecode316Brass cable gland 32mm diaNo99.7599.7520.0FalseNoneNoneFalseNoneFalse1995.00
3799313144101Nonecode317Brass cable gland 45mm diaNo206.85206.8530.0FalseNoneNoneFalseNoneFalse6205.50
3799314144101Nonecode318Aluminium end terminal lug 10 sqmmNo2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3799315144101Nonecode319Aluminium end terminal lug 16 sqmmNo2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3799316144101Nonecode320Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 GmNo147.0147.020.0FalseNoneNoneFalseNoneFalse2940.00
3799317144101Nonecode321Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No4468.84468.88.0FalseNoneNoneFalseNoneFalse35750.40
3799318144101Nonecode322Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripm86.186.150.0FalseNoneNoneFalseNoneFalse4305.00
3799319144101Nonecode323Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI stripm134.4134.420.0FalseNoneNoneFalseNoneFalse2688.00
3799320144101Nonecode324Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm GI Plate.No918.75918.754.0FalseNoneNoneFalseNoneFalse3675.00
3799321144101Nonecode325Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper stripm598.5598.550.0FalseNoneNoneFalseNoneFalse29925.00
3799322144101Nonecode326Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. strip 25x6mm Copper stripm1155.01155.050.0FalseNoneNoneFalseNoneFalse57750.00
3799323144101Nonecode327Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plateNo7792.057792.052.0FalseNoneNoneFalseNoneFalse15584.10
3799324144101Nonecode328Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIless then 70%. efficacy less then100 lumen per W, 120degree beam spread, lifeless then 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF less then 0.95, power loss shouldgrater then 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 10-12WNo1332.451332.455.0FalseNoneNoneFalseNoneFalse6662.250
3799325144101Nonecode329Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIless then 70%. efficacy less then100 lumen per W, 120degree beam spread, lifeless then 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF less then 0.95, power loss shouldgrater then 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 15-18WNo1754.551754.5525.0FalseNoneNoneFalseNoneFalse43863.750
3799326144101Nonecode330Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less then 80. Power Input: 220-240V @ 50/60Hz & Power factor less then0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9/10 wNo578.55578.5535.0FalseNoneNoneFalseNoneFalse20249.250
3799327144101Nonecode331Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less then 80. Power Input: 220-240V @ 50/60Hz & Power factor less then0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 WNo1332.451332.45300.0FalseNoneNoneFalseNoneFalse399735.00
3799328144101Nonecode332Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIless then 70%. efficacy less then100 lumen per watt, 120degree beam spread, lifeless then 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF less then 0.95, power loss should grater then 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 36wattNo4780.654780.6520.0FalseNoneNoneFalseNoneFalse95613.00
3799329144101Nonecode333Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT less then 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire less then IK08. Power Factor less then0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencyless then130lm/w, nominal CRI less then75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNo6291.66291.66.0FalseNoneNoneFalseNoneFalse37749.60
3799330144101Nonecode334Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm)No3117.453117.4540.0FalseNoneNoneFalseNoneFalse124698.00
3799331144101Nonecode335Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 56" Sweep 5 Star (1400 mm)No4991.74991.7120.0FalseNoneNoneFalseNoneFalse599004.00
3799332144101Nonecode336Supplying & Fixing of 70-150 Watts lamp holder 2 PinNo66.1566.1520.0FalseNoneNoneFalseNoneFalse1323.00
3799333144101Nonecode337Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersNo128.1128.130.0FalseNoneNoneFalseNoneFalse3843.00
3799334144101Nonecode338Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.No330.75330.75100.0FalseNoneNoneFalseNoneFalse33075.00
3799335144101Nonecode339Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.No742.35742.3540.0FalseNoneNoneFalseNoneFalse29694.00
3799336144101Nonecode340Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.No514.5514.5350.0FalseNoneNoneFalseNoneFalse180075.00
3799337144101Nonecode341Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthNo1534.051534.056.0FalseNoneNoneFalseNoneFalse9204.30
3799338144101Nonecode342Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNo1359.751359.756.0FalseNoneNoneFalseNoneFalse8158.50
3799339144101Nonecode343Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.No170.1170.16.0FalseNoneNoneFalseNoneFalse1020.60
3799340144101Nonecode344MAIN LT PANEL Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSqm0.450.45150000.0FalseNoneNoneFalseNoneFalse67500.00
3799341144101Nonecode345Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Stripsm2588.252588.255.0FalseNoneNoneFalseNoneFalse12941.250
3799342144101Nonecode346Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm320.25320.2520.0FalseNoneNoneFalseNoneFalse6405.00
3799343144101Nonecode347Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm793.8793.820.0FalseNoneNoneFalseNoneFalse15876.00
3799344144101Nonecode348Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo435.75435.755.0FalseNoneNoneFalseNoneFalse2178.750
3799345144101Nonecode349Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo775.95775.954.0FalseNoneNoneFalseNoneFalse3103.80
3799346144101Nonecode350Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A TPNNo1802.851802.8512.0FalseNoneNoneFalseNoneFalse21634.20
3799347144101Nonecode351Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNo9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3799348144101Nonecode352Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CNo540.75540.7510.0FalseNoneNoneFalseNoneFalse5407.50
3799349144101Nonecode353Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape WoundNo590.1590.110.0FalseNoneNoneFalseNoneFalse5901.00
3799350144101Nonecode354Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V, 125 ANo77527.877527.81.0FalseNoneNoneFalseNoneFalse77527.80
3799351144101Nonecode355EXTERNAL STREET LIGHTING Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32No16275.016275.04.0FalseNoneNoneFalseNoneFalse65100.00
3799352144101Nonecode356Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT less then 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire less then IK08. Power Factor less then0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencyless then130lm/w, nominal CRI less then75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNo6291.66291.64.0FalseNoneNoneFalseNoneFalse25166.40
3799353144101Nonecode357Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNo1359.751359.754.0FalseNoneNoneFalseNoneFalse5439.00
3799354144101Nonecode358Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT less then 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire less then IK08. Power Factor less then0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr HeightNo4755.44755.44.0FalseNoneNoneFalseNoneFalse19021.60
3799355144101Nonecode359Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.No170.1170.14.0FalseNoneNoneFalseNoneFalse680.40
3799356144101Nonecode360Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNo775.95775.953.0FalseNoneNoneFalseNoneFalse2327.850
3799357144101Nonecode361Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting.No2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3799358144101Nonecode362Supplying and fixing of solar Lux level street light control switch single phase including suitable capacity contactor- 8KWNo12621.012621.01.0FalseNoneNoneFalseNoneFalse12621.00
3799359144101Nonecode363Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.3350.0FalseNoneNoneFalseNoneFalse24255.00
3799360144101Nonecode364Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.935.0FalseNoneNoneFalseNoneFalse2866.50
3799361144101Nonecode365Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.445.0FalseNoneNoneFalseNoneFalse3213.00
3799362144101Nonecode366Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.9545.0FalseNoneNoneFalseNoneFalse3732.750
3799363144101Nonecode367IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.No20200.020200.015.0FalseNoneNoneFalseNoneFalse303000.00
3799364144101Nonecode368IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.No21700.021700.03.0FalseNoneNoneFalseNoneFalse65100.00
3799365144101Nonecode369Supplying and drawing UTP-CAT 6E LAN cablem41.841.8800.0FalseNoneNoneFalseNoneFalse33440.00
3799366144101Nonecode370Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as requiredNo14500.014500.01.0FalseNoneNoneFalseNoneFalse14500.00
3799367144101Nonecode371Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as requiredNo40250.040250.01.0FalseNoneNoneFalseNoneFalse40250.00
3799368144101Nonecode372Supply and Installation of I/OsNo125.0125.050.0FalseNoneNoneFalseNoneFalse6250.00
3799369144101Nonecode373Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as requiredNo225.0225.010.0FalseNoneNoneFalseNoneFalse2250.00
3799370144101Nonecode374Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as requiredNo285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3799371144101Nonecode375Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as requiredNo60000.060000.01.0FalseNoneNoneFalseNoneFalse60000.00
3799372144101Nonecode376Design,supplying,erectingtestingandcommissioningof-Passenger/Bed-cum passengerhospitalliftwithspeedof1mtrpersecond,variablevoltagevariablefrequencydrive,withorwithoutmachineroomfortheavailablewellsize,operatingat415V3phase50cyclesACsupply,powdercoated/StainlessSteelcarentrancedoorsenclosureswithsuitablecolourvinylflooring,LEDcarillumination,emergencylight,intercomandfanasdesiredbytheuser,centralopening/sideopeningdoorwithorwithoutattendantoperation,7segmentdisplaybuttons,callregisterindicator,firemandrive,SShandrailsinsidecar,fulllengthinfraredcurtainincardoor,automaticrescuedevicewithbatteries,voiceannouncinginregional/internationallanguages,Braillebuttonswithoneyearwarrantyandmaintenancewithnecessaryscaffoldingandminorcivilworkslikefixingofguiderail,counterweightetc.,ThetotalproductandservicesshalladheretoIS14665/2016(withlatestamendments)part/section1to5withregardstogeneralguidelinesoffiresafetyrateddoors,MRLLbeams,pressureswitch,manualchangeoverfordoorsduringemergency,ARDof10timeswithsufficientbatterybackupandstandarddimensionsofchaircaranddooropeningsforallsizesandcapacitiesofliftsincludingfitnesscertificateanddulyobservingallothersafetynormsprescribedandadheretoCPWDspecifications,PCBNorms,NationalElectricityCode(NEC),NBC-2016,IECandKarnatakaStateLifts,EscalatorsandPassengersConveyersAct 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. With Out Machine Room-PC FinishJob1666957.371666957.371.0FalseNoneNoneFalseNoneFalse1666957.370
3799373144101Nonecode377Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles)No21974.421974.42.0FalseNoneNoneFalseNoneFalse43948.80
3799374144101Nonecode378Erection DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WLNo5640.65640.62.0FalseNoneNoneFalseNoneFalse11281.20
3799375144101Nonecode379Supply& erection of 11 kV, 45 KN Polymeric InsulatorNo195.3195.312.0FalseNoneNoneFalseNoneFalse2343.60
3799376144101Nonecode380Supply of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.53.0FalseNoneNoneFalseNoneFalse3685.50
3799377144101Nonecode381Erection of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.653.0FalseNoneNoneFalseNoneFalse1867.950
3799378144101Nonecode382Supply of Spiral Earth ElectrodeNo250.95250.953.0FalseNoneNoneFalseNoneFalse752.850
3799379144101Nonecode383Erection of Spiral Earth ElectrodeNo97.6597.653.0FalseNoneNoneFalseNoneFalse292.950
3799380144101Nonecode384Supply& fixing of Guy concreting with Boulders, Mud and SandNo262.5262.53.0FalseNoneNoneFalseNoneFalse787.50
3799381144101Nonecode385Supply of Caution/Danger BoardNo157.5157.52.0FalseNoneNoneFalseNoneFalse315.00
3799382144101Nonecode386Fixing of Caution/Danger BoardNo84.084.02.0FalseNoneNoneFalseNoneFalse168.00
3799383144101Nonecode387Supply of Anti Climbing Device (12 Mtr GI Barbed WireNo93.4593.453.0FalseNoneNoneFalseNoneFalse280.350
3799384144101Nonecode388Erection of Anti Climbing Device (12 Mtr GI Barbed WireNo44.144.13.0FalseNoneNoneFalseNoneFalse132.30
3799385144101Nonecode389Supply and fixing of 11 kV, 400 Amps Double Break GOSNo22323.022323.02.0FalseNoneNoneFalseNoneFalse44646.00
3799386144101Nonecode390Fixing of 11 kV, 400 Amps Double Break GOSNo1274.71274.72.0FalseNoneNoneFalseNoneFalse2549.40
3799387144101Nonecode391Supply of H-Frame for mounting GOSNo4548.64548.62.0FalseNoneNoneFalseNoneFalse9097.20
3799388144101Nonecode392fixing of H-Frame for mounting GOSNo339.15339.152.0FalseNoneNoneFalseNoneFalse678.30
3799389144101Nonecode393Supply of DOLO Cut OutNo6165.66165.62.0FalseNoneNoneFalseNoneFalse12331.20
3799390144101Nonecode394Erection of DOLO Cut OutNo248.85248.852.0FalseNoneNoneFalseNoneFalse497.70
3799391144101Nonecode39511KV EXTENSION Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785No7429.87429.82.0FalseNoneNoneFalseNoneFalse14859.60
3799392144101Nonecode396Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785No1829.11829.12.0FalseNoneNoneFalseNoneFalse3658.20
3799393144101Nonecode397Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNo678.3678.32.0FalseNoneNoneFalseNoneFalse1356.60
3799394144101Nonecode398Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNo285.6285.62.0FalseNoneNoneFalseNoneFalse571.20
3799395144101Nonecode399Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)No215.25215.256.0FalseNoneNoneFalseNoneFalse1291.50
3799396144101Nonecode400Supply and fixing of 11 kV, 45 KN Polymeric InsulatorNo195.3195.36.0FalseNoneNoneFalseNoneFalse1171.80
3799397144101Nonecode401Supply of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.52.0FalseNoneNoneFalseNoneFalse2457.00
3799398144101Nonecode402Erection of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.652.0FalseNoneNoneFalseNoneFalse1245.30
3799399144101Nonecode403Supply of Rabbit ACSR ConductorKm48545.748545.71.0FalseNoneNoneFalseNoneFalse48545.70
3799400144101Nonecode404Erection of Rabbit ACSR ConductorKm4579.054579.051.0FalseNoneNoneFalseNoneFalse4579.050
3799401144101Nonecode405Supply and fixing of PG Clamps for Rabbit ConductorNo107.1107.115.0FalseNoneNoneFalseNoneFalse1606.50
3799402144101Nonecode406Supply of Spiral Earth ElectrodeNo250.95250.952.0FalseNoneNoneFalseNoneFalse501.90
3799403144101Nonecode407Erection of Spiral Earth ElectrodeNo97.6597.652.0FalseNoneNoneFalseNoneFalse195.30
3799404144101Nonecode408Supply of EG Stirrups with GI wire lacingNo289.8289.82.0FalseNoneNoneFalseNoneFalse579.60
3799405144101Nonecode409Erection of EG Stirrups with GI wire lacingNo168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3799406144101Nonecode410Guy concreting with Boulders, Mud and SandNo262.5262.52.0FalseNoneNoneFalseNoneFalse525.00
3799407144101Nonecode411Supply of Caution/Danger BoardNo157.5157.53.0FalseNoneNoneFalseNoneFalse472.50
3799408144101Nonecode412Erection of Caution/Danger BoardNo84.084.03.0FalseNoneNoneFalseNoneFalse252.00
3799409144101Nonecode413Supply of Anti Climbing Device (12 Mtr GI Barbed WireNo93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3799410144101Nonecode414Erection of Anti Climbing Device (12 Mtr GI Barbed WireNo44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3799411144101Nonecode415Erection of 3 Phase, 11kV/433V, 63 kVA BEE 4/5 Star Rated Distribution Transformer Centre Using DPTS Using PSCC Pole - 9 Mtr Long, 300 Kg WL supplying of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No29051.429051.41.0FalseNoneNoneFalseNoneFalse29051.40
3799412144101Nonecode416supplying & fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)No215.25215.253.0FalseNoneNoneFalseNoneFalse645.750
3799413144101Nonecode417supplying & fixing of 11 kV, 45 KN Polymeric InsulatorNo195.3195.33.0FalseNoneNoneFalseNoneFalse585.90
3799414144101Nonecode418Supplying of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.54.0FalseNoneNoneFalseNoneFalse4914.00
3799415144101Nonecode419Supplying of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo191672.25191672.251.0FalseNoneNoneFalseNoneFalse191672.250
3799416144101Nonecode420Supplying of Earthing materials pipe type for grounding (Single Electrode with accessories)No1815.451815.453.0FalseNoneNoneFalseNoneFalse5446.350
3799417144101Nonecode421Supplying of Caution/Danger BoardNo157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3799418144101Nonecode422supplying of Anti Climbing Device (12 Mtr GI Barbed Wire)No93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3799419144101Nonecode423Supplying & fixing of GI Wire 8 SWGKg78.7978.795.0FalseNoneNoneFalseNoneFalse393.950
3799420144101Nonecode424Supplying & fixing of Guy wire 7/10 SWGKg81.0981.0910.0FalseNoneNoneFalseNoneFalse810.90
3799421144101Nonecode425Supplying & fixing of 11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA, Polymeric type with ground disconnectorNo4989.64989.61.0FalseNoneNoneFalseNoneFalse4989.60
3799422144101Nonecode426a) Supplying of LT Protection Kit for 63 kVANo2124.152124.152.0FalseNoneNoneFalseNoneFalse4248.30
3799423144101Nonecode427b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmmm116.85116.8540.0FalseNoneNoneFalseNoneFalse4674.00
3799424144101Nonecode428b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT ii) Heavy Duty Long Barrel Copper Lug - 95 SqmmNo135.45135.454.0FalseNoneNoneFalseNoneFalse541.80
3799425144101Nonecode429b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iii) PG Clamp - Rabbit to 95 SqmmNo147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
3799426144101Nonecode430b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iv) Spacer for DTC WiringNo44.144.18.0FalseNoneNoneFalseNoneFalse352.80
3799427144101Nonecode431b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)No277.2277.22.0FalseNoneNoneFalseNoneFalse554.40
3799428144101Nonecode432c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No5905.25905.21.0FalseNoneNoneFalseNoneFalse5905.20
3799429144101Nonecode433d) LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo3565.83565.81.0FalseNoneNoneFalseNoneFalse3565.80
3799430144101Nonecode434Supplying of 11 kV, Solid Core Type HG Fuse UnitNo1122.451122.451.0FalseNoneNoneFalseNoneFalse1122.450
3799431144101Nonecode435suppying of 11 kV, 200 Amps, Single Break GOSNo9922.59922.51.0FalseNoneNoneFalseNoneFalse9922.50
3799432144101Nonecode436Fixing of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No7332.157332.151.0FalseNoneNoneFalseNoneFalse7332.150
3799433144101Nonecode437Fixing of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.654.0FalseNoneNoneFalseNoneFalse2490.60
3799434144101Nonecode438Fixing of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo1252.651252.651.0FalseNoneNoneFalseNoneFalse1252.650
3799435144101Nonecode439Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories)No996.45996.453.0FalseNoneNoneFalseNoneFalse2989.350
3799436144101Nonecode440Fixing of Caution/Danger BoardNo84.084.01.0FalseNoneNoneFalseNoneFalse84.00
3799437144101Nonecode441Fixing Anti Climbing Device (12 Mtr GI Barbed Wire)No44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3799438144101Nonecode442Fixing of Guy concreting with Boulders, Mud and SandNo262.5262.54.0FalseNoneNoneFalseNoneFalse1050.00
3799439144101Nonecode443a) Fixing of LT Protection Kit for 63 kVANo373.8373.82.0FalseNoneNoneFalseNoneFalse747.60
3799440144101Nonecode444b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmm ii) Heavy Duty Long Barrel Copper Lug - 95 Sqmm iii) PG Clamp - Rabbit to 95 Sqmm iv) Spacer for DTC Wiring v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)No996.45996.451.0FalseNoneNoneFalseNoneFalse996.450
3799441144101Nonecode445c) fixing of LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No908.25908.251.0FalseNoneNoneFalseNoneFalse908.250
3799442144101Nonecode446d) fixing of LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3799443144101Nonecode447fixing of 11 kV, Solid Core Type HG Fuse UnitNo248.85248.851.0FalseNoneNoneFalseNoneFalse248.850
3799444144101Nonecode448Fixing of 11 kV, 200 Amps, Single Break GOSNo1159.21159.21.0FalseNoneNoneFalseNoneFalse1159.20
3799445144101Nonecode449SUMP TANK EARTH WORK Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m Page No. 8,Sl. No.1.14Cum107.1107.156.0FalseNoneNoneFalseNoneFalse5997.60
3799446144101Nonecode450PCC BED Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.2, Page No.15Cum5947.25947.24.0FalseNoneNoneFalseNoneFalse23788.80
3799447144101Nonecode451EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7Cum279.3279.33.69FalseNoneNoneFalseNoneFalse1030.6170
3799448144101Nonecode452Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24Cum7185.027185.024.85FalseNoneNoneFalseNoneFalse34847.3470
3799449144101Nonecode453RCC Work Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-ICum7903.677903.678.09FalseNoneNoneFalseNoneFalse63940.69030
3799450144101Nonecode454Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum10777.7310777.734.85FalseNoneNoneFalseNoneFalse52271.99050
3799451144101Nonecode455PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42 Volume-IISqm404.25404.2588.0FalseNoneNoneFalseNoneFalse35574.00
3799452144101Nonecode456Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer-in-Charge. Sl. No. 8.12, Page No.43 Volume-IISqm67.267.288.0FalseNoneNoneFalseNoneFalse5913.60
3799453144101Nonecode457KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification (Page No. 75, Sl. No. 11.45)No283.5283.510.0FalseNoneNoneFalseNoneFalse2835.00
3799454144101Nonecode458STEEL Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Sl. No. 2.11 a, Page No.18 Volume-IKg82961.5582961.553.84FalseNoneNoneFalseNoneFalse318572.3520
3799455144101Nonecode459Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete V0L-V SL No 12.4 V-5 PG:140No5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3799456144101Nonecode460Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50mtr 12.2.1m324.45324.4550.0FalseNoneNoneFalseNoneFalse16222.50
3799457144101Nonecode461Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50 to 100 mtr 12.2.2m406.35406.3550.0FalseNoneNoneFalseNoneFalse20317.50
3799458144101Nonecode462Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 100 to 150 mtr 12.2.3m432.6432.650.0FalseNoneNoneFalseNoneFalse21630.00
3799459144101Nonecode463Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 150 to 200mtr 12.2.4m501.9501.950.0FalseNoneNoneFalseNoneFalse25095.00
3799460144101Nonecode464Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 VOL-V SL No 10.1.8 pg 113 V-5 140 mm dia casing pipesm613.2613.2180.0FalseNoneNoneFalseNoneFalse110376.00
3799461144101Nonecode465Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (VOL-V) SL No 13.15.7 V-6 PG: 152No42850.542850.51.0FalseNoneNoneFalseNoneFalse42850.50
3799462144101Nonecode466Supplyinganddrawing3coreflatPVCsheathedsubmersiblepumpcablemanufacturedwithelectrolyticgradecopperwithflexiblecopperwithlowresistanceconductorconfirmingto13:8130 1984andvirgingradePVCinsulationandpowdercoatingextrudedPVCsheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 mm2 SL No: 2.6.2 V-6 PG: 7m176.4176.4330.0FalseNoneNoneFalseNoneFalse58212.00
3799463144101Nonecode467Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valves VOL-V ) 50 mm Size = 1No SL No: 11.15.6 pg 133 V-5No1772.41772.41.0FalseNoneNoneFalseNoneFalse1772.40
3799464144101Nonecode468Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (IT NO 28.1 PG NO 162 ) VOL-V 50 mm Size = 1No SL No: 13.25.1 pg 154 V-5No1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3799465144101Nonecode469Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter (6 to 15 HP pumps) IT NO 30.2 & PG NO-162 VOL-V SL No: 13.24.3 pg 155 V-5No18375.018375.01.0FalseNoneNoneFalseNoneFalse18375.00
3799466144101Nonecode470Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ( IT NO 38 & PG NO-163 ,VOL-V) SL No: 13.32 pg 156 V-5No6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3799467144101Nonecode471Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 7.5 HP, size 100x100 Head 195M, Discharge 1200 LPM SL No:13.40.6 PG: 157 V-5No32046.032046.01.0FalseNoneNoneFalseNoneFalse32046.00
3799468144101Nonecode472Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. All items are of ISI standards. 2. After commissioning of plant necessary testing to be done for the 3. Satisfaction of the Engineer in charge. 4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. Page No. 251 ,Sl. No-22.2.1 B. VOL-5 STP ( 25 KLD)No1359750.01359750.01.0FalseNoneNoneFalseNoneFalse1359750.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17238978480000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17238978480000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17238978480000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17238978480000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17238978480000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17238978550000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17238978580000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17238978620000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17238978660000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17238978690000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17238978730000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17238978760000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17238978790000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17238978830000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17238979070000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17238979100000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17238979130000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17238979170000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17238979230000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17238979270000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724159865000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone