1724150338000 | 0 | None | None | Buildings | Construction of Water Re-Cycling plant (ETP) for bus depot at Muddebihal. (SC Reserved) (Call-3) | 417640.84 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3820033 | 145330 | None | code01 | Item Description: Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) In all kinds of soils Depth upto 3 m | No | 76.65 | 76.65 | 48.96 | False | None | None | False | None | False | 3752.784 | 0 | 3820034 | 145330 | None | code02 | Item Description: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | No | 5466.3 | 5466.3 | 3.33 | False | None | None | False | None | False | 18202.779 | 0 | 3820035 | 145330 | None | code03 | Item Description: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated) | No | 6739.36 | 6739.36 | 2.08 | False | None | None | False | None | False | 14017.8688 | 0 | 3820036 | 145330 | None | code04 | Item Description: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1a. (Plinth Beam of Building) | No | 9736.65 | 9736.65 | 8.15 | False | None | None | False | None | False | 79353.6975 | 0 | 3820037 | 145330 | None | code05 | Item Description: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof (Straight & Arched) | No | 9736.65 | 9736.65 | 0.25 | False | None | None | False | None | False | 2434.1625 | 0 | 3820038 | 145330 | None | code06 | Item Description: SR 2018-19 SRP 15/4.19 Providing and laying in position reinforced cement concrete of design Mix M20 with OPC @ 24 KGS with 12 mm and down size graded granite metal coarse aggregates @ 0.05175 cum and fine aggregates @ 0.0345 cum with super plasticisers @ 0.225 lts. machine mixed well compacted for plain chajja of 7.5 cms. average thickness upto ground floor level including cost of all materials, labour HOM finishing, curing, complete but excluding cost of reinforcement as per specifications. | No | 438.0 | 438.0 | 11.34 | False | None | None | False | None | False | 4966.92 | 0 | 3820039 | 145330 | None | code07 | Item Description: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof beams ) | No | 10385.76 | 10385.76 | 0.31 | False | None | None | False | None | False | 3219.5856 | 0 | 3820040 | 145330 | None | code08 | Item Description: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2) | No | 241.5 | 241.5 | 31.71 | False | None | None | False | None | False | 7657.965 | 0 | 3820041 | 145330 | None | code09 | Item Description: Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-II (84/11.32) | No | 96.6 | 96.6 | 1161.45 | False | None | None | False | None | False | 112196.07 | 0 | 3820042 | 145330 | None | code10 | Item Description: Providing & filling Quartz Sand (in Sand filter Media) including filling etc., complete SRP II/60/ 0781 | No | 11.0 | 11.0 | 2148.12 | False | None | None | False | None | False | 23629.32 | 0 | 3820043 | 145330 | None | code11 | Item Description: Providing & Filling activated carbon as filter media in Setling tank | No | 38.0 | 38.0 | 537.03 | False | None | None | False | None | False | 20407.14 | 0 | 3820044 | 145330 | None | code12 | Item Description: Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Apex Paint) SRP- Vol-II (45/8.28) | No | 69.3 | 69.3 | 50.0 | False | None | None | False | None | False | 3465.0 | 0 | 3820045 | 145330 | None | code13 | Item Description: Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (11/13.33.6) 40 mm | No | 492.45 | 492.45 | 10.0 | False | None | None | False | None | False | 4924.5 | 0 | 3820046 | 145330 | None | code14 | Item Description: Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (11/13.33.6) 25 mm | No | 313.95 | 313.95 | 50.0 | False | None | None | False | None | False | 15697.5 | 0 | 3820047 | 145330 | None | code15 | Item Description: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/34A) | No | 152.25 | 152.25 | 37.8 | False | None | None | False | None | False | 5755.05 | 0 | 3820048 | 145330 | None | code16 | Item Description: Constructing brick maconary inspection chamber of internal dimention 600 450 mm, and depth of 600mm (Inner dimension) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover) SRP- Vol-V 187/8/T130A | No | 4592.7 | 4592.7 | 2.0 | False | None | None | False | None | False | 9185.4 | 0 | 3820049 | 145330 | None | code17 | Item Description: Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.7) | No | 413.7 | 413.7 | 12.0 | False | None | None | False | None | False | 4964.4 | 0 | 3820050 | 145330 | None | code18 | Item Description: Providing and placing on terrace polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet uolet and over flow pipes includng cost of ll materials, labour transport charges HOM of equipments and testing complete as per specification VOL II SRP 13.34A (For 1000 ltr capacity) | No | 8.4 | 8.4 | 4000.0 | False | None | None | False | None | False | 33600.0 | 0 | 3820051 | 145330 | None | code19 | Item Description: Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.9) | No | 628.95 | 628.95 | 30.0 | False | None | None | False | None | False | 18868.5 | 0 | 3820052 | 145330 | None | code20 | Item Description: Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground SRP- Vol-I (A-45/50) | No | 991.2 | 991.2 | 6.0 | False | None | None | False | None | False | 5947.2 | 0 | 3820053 | 145330 | None | code21 | Item Description: 11.9.2 100W Supply of LED floodlight luminaire withpressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser withInjection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 CCT 5500K,IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08.Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/Overload short circuit/miss-wiring protection Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application Compliance to IS 10322/IEC 60598,LM79 & LM 80 Adherence withRoHS.UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility supplier word mark/name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above shouldcertified by ISO 9001 2008. Housing with | No | 8172.0 | 8172.0 | 3.0 | False | None | None | False | None | False | 24516.0 | 0 | 3820054 | 145330 | None | code22 | Item Description: 13.5 Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | No | 189.0 | 189.0 | 3.0 | False | None | None | False | None | False | 567.0 | 0 | 3820055 | 145330 | None | code23 | Item Description: 2.3.2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 mm2 | No | 26.0 | 26.0 | 12.0 | False | None | None | False | None | False | 312.0 | 0 |
|