3818653 | 145241 | None | Volume-1, I No. 1.5.2, Pg No. 6 | Earth work excavation by manual means for drains,canals, waste weir draft,
approach channels, key trench, foundation of Bridges and such similar works,
as per drawing and technical specifications, including setting out, shoring,
strutting, barricading, caution lights, excavated surface leveled and sides neatly
dressed disposing off or leveling the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m | Cum | 467.25 | 467.25 | 13.57 | False | None | None | False | None | False | 6340.5825 | 0 |
3818654 | 145241 | None | Volume-1, I No. 2.1.4, Pg No. 15 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 1.51 | False | None | None | False | None | False | 9857.0535 | 0 |
3818655 | 145241 | None | Volume-1, I No. 2.4.3, Pg No. 17 | Providing and laying in position Cement Concrete for all Sub structures of
building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 5.14 | False | None | None | False | None | False | 34195.392 | 0 |
3818656 | 145241 | None | Vol-2, I No. 5.4. P No. 8 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth
level with : Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 4.25 | False | None | None | False | None | False | 28510.9125 | 0 |
3818657 | 145241 | None | Pg.No. 7 Item.No.1.9 Volume 1 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipment's with all lead and lifts, loading and unloading charges etc. Complete as directed as per specification and direction of Engineer in-charge of the work. | Cum | 279.3 | 279.3 | 23.63 | False | None | None | False | None | False | 6599.859 | 0 |
3818658 | 145241 | None | Pg.No. 16 Item.No.2.5.2 Volume 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 1.13 | False | None | None | False | None | False | 8119.2195 | 0 |
3818659 | 145241 | None | Pg.No. 111 Sl No.9, Volume 1 | Additionalities for Formwork, Centering & Scaffolding Plinth Beams of Building & Roof slab of building 50% | Cum | 3592.58 | 3592.58 | 1.13 | False | None | None | False | None | False | 4059.6154 | 0 |
3818660 | 145241 | None | It No 2.11h page no. 18, Vol-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures | Tonne | 82961.55 | 82961.55 | 0.62 | False | None | None | False | None | False | 51436.161 | 0 |
3818661 | 145241 | None | Pg.No. 14 Item.No.6.8 Volume 2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 4.17 | False | None | None | False | None | False | 34892.2665 | 0 |
3818662 | 145241 | None | Pg.No. 41 Item.No.8.2.2 Volume 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipment's with all lead and lifts, loading and unloading charges etc. Complete as directed as per specification and direction of Engineer in-charge of the work. | Sqm | 292.95 | 292.95 | 79.35 | False | None | None | False | None | False | 23245.5825 | 0 |
3818663 | 145241 | None | Pg.No. 41 Item.No.8.1.2 Volume 2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 7.2 | False | None | None | False | None | False | 1821.96 | 0 |
3818664 | 145241 | None | Pg.No. 82 Item.No. 11.25.2 Volume 2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 142.8 | 142.8 | 1170.0 | False | None | None | False | None | False | 167076.0 | 0 |
3818665 | 145241 | None | Pg.No. 60 Item.No. 9.8 Volume 2 | Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete. | Kg | 147.0 | 147.0 | 874.8 | False | None | None | False | None | False | 128595.6 | 0 |
3818666 | 145241 | None | Pg.No. 26 Item.No. 7.38 Volume 2 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 596.4 | 596.4 | 108.5 | False | None | None | False | None | False | 64709.4 | 0 |
3818667 | 145241 | None | Pg.No. 85 Item.No. 11.34B Volume 2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Sqm | 192.15 | 192.15 | 693.0 | False | None | None | False | None | False | 133159.95 | 0 |
3818668 | 145241 | None | Pg.No. 133 Item.No. 15.1 Volume 2 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 857.85 | 857.85 | 55.0 | False | None | None | False | None | False | 47181.75 | 0 |
3818669 | 145241 | None | Pg.No. 78 Item.No. 11.6.3 Volume 2 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength
conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2388.75 | 2388.75 | 2.52 | False | None | None | False | None | False | 6019.65 | 0 |
3818670 | 145241 | None | Pg.No. 25 Item.No. 7.31 Volume 2 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. | Sqm | 1229.55 | 1229.55 | 117.0 | False | None | None | False | None | False | 143857.35 | 0 |
3818671 | 145241 | None | Pg.No. 2 Item.No.1.2.1 Volume 6(ELE) | Supplying heavy gauge PVC conduit pipe . mm dia.mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junctionboxes, adhesive paste etc., and running before concreting the slab. Theconduit should be tied to the reinforcement rods by using bindingwires and unused ways of junction boxes and pipe ends should becovered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | Rmtr | 69.3 | 69.3 | 300.0 | False | None | None | False | None | False | 20790.0 | 0 |
3818672 | 145241 | None | Pg.No. 5 Item.No.2.2.2 Volume 6(ELE) | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 397.95 | 397.95 | 12.0 | False | None | None | False | None | False | 4775.4 | 0 |
3818673 | 145241 | None | Pg.No. 5 Item.No.2.2.3 Volume 6(ELE) | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 582.75 | 582.75 | 4.0 | False | None | None | False | None | False | 2331.0 | 0 |
3818674 | 145241 | None | Pg.No. 5 Item.No.2.3.2 Volume 6(ELE) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS 694:2010 1.5 mm2 | Mtr | 27.3 | 27.3 | 90.0 | False | None | None | False | None | False | 2457.0 | 0 |
3818675 | 145241 | None | Pg.No. 5 Item.No.2.3.3 Volume 6(ELE) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS 694:2010 2.5 mm2 | Mtr | 44.1 | 44.1 | 90.0 | False | None | None | False | None | False | 3969.0 | 0 |
3818676 | 145241 | None | Pg.No. 8 Item.No.3.4.3 Volume 6(ELE) | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way | No | 185.85 | 185.85 | 2.0 | False | None | None | False | None | False | 371.7 | 0 |
3818677 | 145241 | None | Pg.No. 8 Item.No.3.4.6 Volume 6(ELE) | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way | Nos | 334.95 | 334.95 | 1.0 | False | None | None | False | None | False | 334.95 | 0 |
3818678 | 145241 | None | Pg.No. 8 Item.No.3.4.7 Volume 6(ELE) | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way | Nos | 381.15 | 381.15 | 1.0 | False | None | None | False | None | False | 381.15 | 0 |
3818679 | 145241 | None | Pg.No. 8 Item.No.3.4.8 Volume 6(ELE) | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 Way | Nos | 425.25 | 425.25 | 1.0 | False | None | None | False | None | False | 425.25 | 0 |
3818680 | 145241 | None | Pg.No. 08 Item.No.3.5.3 Volume 6(ELE) | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Nos | 183.75 | 183.75 | 2.0 | False | None | None | False | None | False | 367.5 | 0 |
3818681 | 145241 | None | Pg.No. 08 Item.No.3.5.4 Volume 6(ELE) | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Nos | 245.7 | 245.7 | 1.0 | False | None | None | False | None | False | 245.7 | 0 |
3818682 | 145241 | None | Pg.No. 08 Item.No.3.5.5 Volume 6(ELE) | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Nos | 298.2 | 298.2 | 1.0 | False | None | None | False | None | False | 298.2 | 0 |
3818683 | 145241 | None | Pg.No. 08 Item.No.3.5.6 Volume 6(ELE) | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Nos | 361.2 | 361.2 | 1.0 | False | None | None | False | None | False | 361.2 | 0 |
3818684 | 145241 | None | Pg.No. 08 Item.No.3.5.7 Volume 6(ELE) | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16 Module | Nos | 416.85 | 416.85 | 1.0 | False | None | None | False | None | False | 416.85 | 0 |
3818685 | 145241 | None | Pg.No. 08 Item.No.3.5.8 Volume 6(ELE) | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18 Module | Nos | 479.85 | 479.85 | 1.0 | False | None | None | False | None | False | 479.85 | 0 |
3818686 | 145241 | None | Pg.No. 09 Item.No.3.6.1 Volume 6(ELE) | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Nos | 107.1 | 107.1 | 22.0 | False | None | None | False | None | False | 2356.2 | 0 |
3818687 | 145241 | None | Pg.No. 09 Item.No.3.6.3 Volume 6(ELE) | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Nos | 179.55 | 179.55 | 8.0 | False | None | None | False | None | False | 1436.4 | 0 |
3818688 | 145241 | None | Pg.No. 09 Item.No.3.6.4 Volume 6(ELE) | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Nos | 374.85 | 374.85 | 6.0 | False | None | None | False | None | False | 2249.1 | 0 |
3818689 | 145241 | None | Pg.No. 10 Item.No.3.14.6 Volume 6(ELE) | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Pendant Holder | Nos | 74.55 | 74.55 | 16.0 | False | None | None | False | None | False | 1192.8 | 0 |
3818690 | 145241 | None | Pg.No. 43 Item.No.11.3.3 Volume 6(ELE) | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 lumen maintenance with CRI greater than 80 Power Input 220 to 240V@ 50 or 60Hz & Power factor greate than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1X4 feet 36 or 40 W | Nos | 1332.45 | 1332.45 | 10.0 | False | None | None | False | None | False | 13324.5 | 0 |
3818691 | 145241 | None | Pg.No. 46 Item.No.11.8.4 Volume 6(ELE) | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location withminimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 90 W | Each | 9303.0 | 9303.0 | 1.0 | False | None | None | False | None | False | 9303.0 | 0 |
3818692 | 145241 | None | Pg.No. 45 Item.No.11.6.5 Volume 6(ELE) | Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should greater than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested byNABL/CPRI accredited laboratory with 2 years Warranty againstany manufacturing defect working under standard electrical condition. LED modular down light 1'x4' 34-36W | Nos | 6192.9 | 6192.9 | 6.0 | False | None | None | False | None | False | 37157.4 | 0 |
3818693 | 145241 | None | Pg.No. 43 Item.No.11.2.1 Volume 6(ELE) | Supplying & fixing retrofit type-PL- LED Lamp . W LED linear source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HFelectronic driver integrated in the system, with PF greater than 0.95, power loss should Smaller than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 654.15 | 654.15 | 3.0 | False | None | None | False | None | False | 1962.45 | 0 |
3818694 | 145241 | None | Pg.No. 56 Item.No.13.7.1 Volume 6(ELE) | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling /Rafter / Girders | Nos | 128.1 | 128.1 | 33.0 | False | None | None | False | None | False | 4227.3 | 0 |
3818695 | 145241 | None | Pg.No. 30 Item.No.6.3.1 Volume 6(ELE) | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Nos | 3133.2 | 3133.2 | 6.0 | False | None | None | False | None | False | 18799.2 | 0 |
3818696 | 145241 | None | Pg.No. 57 Item.No.13.11 Volume 6(ELE) | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Nos | 330.75 | 330.75 | 6.0 | False | None | None | False | None | False | 1984.5 | 0 |
3818697 | 145241 | None | Pg.No. 57 Item.No.13.12 Volume 6(ELE) | Extra length of GI pipe of class B 19mm dia for down rod. | Mtr | 206.85 | 206.85 | 6.0 | False | None | None | False | None | False | 1241.1 | 0 |
3818698 | 145241 | None | Pg.No. 30 Item.No.6.2.1 Volume 6(ELE) | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) | Nos | 3117.45 | 3117.45 | 6.0 | False | None | None | False | None | False | 18704.7 | 0 |
3818699 | 145241 | None | Pg.No. 57 Item.No.13.13 Volume 6(ELE) | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Nos | 742.35 | 742.35 | 2.0 | False | None | None | False | None | False | 1484.7 | 0 |
3818700 | 145241 | None | Pg.No. 17 Item.No.5.18.4 Volume 6(ELE) | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Typecurve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP | Nos | 775.95 | 775.95 | 3.0 | False | None | None | False | None | False | 2327.85 | 0 |
3818701 | 145241 | None | Pg.No. 17 Item.No.5.18.5 Volume 6(ELE) | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Typecurve, indicator ON OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Nos | 1113.0 | 1113.0 | 1.0 | False | None | None | False | None | False | 1113.0 | 0 |
3818702 | 145241 | None | Pg.No. 17 Item.No.5.17.2 Volume 6(ELE) | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 8 Way | Nos | 13235.25 | 13235.25 | 1.0 | False | None | None | False | None | False | 13235.25 | 0 |
3818703 | 145241 | None | Pg.No. 56 Item.No.13.1.1 Volume 6(ELE) | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | Each | 1026.9 | 1026.9 | 1.0 | False | None | None | False | None | False | 1026.9 | 0 |
3818704 | 145241 | None | Pg.No. 2 Item.No.1.1.3 Volume 6(ELE) | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thick | Mtr | 111.3 | 111.3 | 8.0 | False | None | None | False | None | False | 890.4 | 0 |
3818705 | 145241 | None | Pg.No. 13 Item.No.32.05 Volume 6(ELE) | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Each | 148934.1 | 148934.1 | 0.04 | False | None | None | False | None | False | 5957.364 | 0 |
3818706 | 145241 | None | Pg.No. 15 Item.No.35.01 Volume 6(ELE) | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 Sqmm page no.10 | Set | 340.2 | 340.2 | 1.0 | False | None | None | False | None | False | 340.2 | 0 |
3818707 | 145241 | None | Pg.No. 63 Item.No.29.03 Volume 6(ELE) | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Hard Soil | Cum | 408.45 | 408.45 | 11.62 | False | None | None | False | None | False | 4746.189 | 0 |
3818708 | 145241 | None | Pg.No. 52 Item.No.21.05 Volume 6(ELE) | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm | Km | 21909.3 | 21909.3 | 0.04 | False | None | None | False | None | False | 876.372 | 0 |
3818709 | 145241 | None | Pg.No. 38 Item.No.48.04 Volume 6(ELE) | GI Pipe B - Class as per IS-1239 GI Pipe - 40 mm Dia | Mtr | 262.5 | 262.5 | 6.0 | False | None | None | False | None | False | 1575.0 | 0 |
3818710 | 145241 | None | Pg.No. 22 Item.No.51.01 Volume 6(ELE) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | Nos | 780.15 | 780.15 | 1.0 | False | None | None | False | None | False | 780.15 | 0 |