createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724145897867
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd32300.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-09-2024 16:00:00
tenderQueryClose29-08-2024 11:00:00
technicalBidOpenNone
publishedDate20-08-2024 15:53:10
publishedByPostDMA_EE4_CC_HD
publishedByUserKPE13801 - VIJAYAKUMAR R
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonVijayakumar R
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber7795455548
mobileNumber7795455548
tenderSupplierListNone
tenderSchedule
createdTs1724145897911
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT24937
titleConstruction of Kamaripeth Samudhaya Bhavan at ward no. 65 (Continued work)
descriptionConstruction of Kamaripeth Samudhaya Bhavan at ward no. 65 (Continued work)
categoryWORKS
categoryTextWorks
ecv1281450.58
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2170
locationNameDMA City Corporation Hubballi-Dharawada
provisionalAmount1290000.0
groupOverheadTotal195475.51
fileNumber225849
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17241458980000NoneNoneBuildingsConstruction of Kamaripeth Samudhaya Bhavan at ward no. 65 (Continued work)1085975.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3818653145241NoneVolume-1, I No. 1.5.2, Pg No. 6Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.2513.57FalseNoneNoneFalseNoneFalse6340.58250
3818654145241NoneVolume-1, I No. 2.1.4, Pg No. 15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.51FalseNoneNoneFalseNoneFalse9857.05350
3818655145241NoneVolume-1, I No. 2.4.3, Pg No. 17Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.85.14FalseNoneNoneFalseNoneFalse34195.3920
3818656145241NoneVol-2, I No. 5.4. P No. 8Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.454.25FalseNoneNoneFalseNoneFalse28510.91250
3818657145241NonePg.No. 7 Item.No.1.9 Volume 1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipment's with all lead and lifts, loading and unloading charges etc. Complete as directed as per specification and direction of Engineer in-charge of the work.Cum279.3279.323.63FalseNoneNoneFalseNoneFalse6599.8590
3818658145241NonePg.No. 16 Item.No.2.5.2 Volume 1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.151.13FalseNoneNoneFalseNoneFalse8119.21950
3818659145241NonePg.No. 111 Sl No.9, Volume 1Additionalities for Formwork, Centering & Scaffolding Plinth Beams of Building & Roof slab of building 50%Cum3592.583592.581.13FalseNoneNoneFalseNoneFalse4059.61540
3818660145241NoneIt No 2.11h page no. 18, Vol-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structuresTonne82961.5582961.550.62FalseNoneNoneFalseNoneFalse51436.1610
3818661145241NonePg.No. 14 Item.No.6.8 Volume 2Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.454.17FalseNoneNoneFalseNoneFalse34892.26650
3818662145241NonePg.No. 41 Item.No.8.2.2 Volume 2 Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Including cost and conveyance of all materials, Labour, Hire charges of Machineries and Equipment's with all lead and lifts, loading and unloading charges etc. Complete as directed as per specification and direction of Engineer in-charge of the work.Sqm292.95292.9579.35FalseNoneNoneFalseNoneFalse23245.58250
3818663145241NonePg.No. 41 Item.No.8.1.2 Volume 2 Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.057.2FalseNoneNoneFalseNoneFalse1821.960
3818664145241NonePg.No. 82 Item.No. 11.25.2 Volume 2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg142.8142.81170.0FalseNoneNoneFalseNoneFalse167076.00
3818665145241NonePg.No. 60 Item.No. 9.8 Volume 2Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete.Kg147.0147.0874.8FalseNoneNoneFalseNoneFalse128595.60
3818666145241NonePg.No. 26 Item.No. 7.38 Volume 2Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm596.4596.4108.5FalseNoneNoneFalseNoneFalse64709.40
3818667145241NonePg.No. 85 Item.No. 11.34B Volume 2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15693.0FalseNoneNoneFalseNoneFalse133159.950
3818668145241NonePg.No. 133 Item.No. 15.1 Volume 2 Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm857.85857.8555.0FalseNoneNoneFalseNoneFalse47181.750
3818669145241NonePg.No. 78 Item.No. 11.6.3 Volume 2Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2388.752388.752.52FalseNoneNoneFalseNoneFalse6019.650
3818670145241NonePg.No. 25 Item.No. 7.31 Volume 2 Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.Sqm1229.551229.55117.0FalseNoneNoneFalseNoneFalse143857.350
3818671145241NonePg.No. 2 Item.No.1.2.1 Volume 6(ELE)Supplying heavy gauge PVC conduit pipe . mm dia.mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junctionboxes, adhesive paste etc., and running before concreting the slab. Theconduit should be tied to the reinforcement rods by using bindingwires and unused ways of junction boxes and pipe ends should becovered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickRmtr69.369.3300.0FalseNoneNoneFalseNoneFalse20790.00
3818672145241NonePg.No. 5 Item.No.2.2.2 Volume 6(ELE)Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.9512.0FalseNoneNoneFalseNoneFalse4775.40
3818673145241NonePg.No. 5 Item.No.2.2.3 Volume 6(ELE)Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.754.0FalseNoneNoneFalseNoneFalse2331.00
3818674145241NonePg.No. 5 Item.No.2.3.2 Volume 6(ELE)Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS 694:2010 1.5 mm2Mtr27.327.390.0FalseNoneNoneFalseNoneFalse2457.00
3818675145241NonePg.No. 5 Item.No.2.3.3 Volume 6(ELE)Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS 694:2010 2.5 mm2Mtr44.144.190.0FalseNoneNoneFalseNoneFalse3969.00
3818676145241NonePg.No. 8 Item.No.3.4.3 Volume 6(ELE)Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 WayNo185.85185.852.0FalseNoneNoneFalseNoneFalse371.70
3818677145241NonePg.No. 8 Item.No.3.4.6 Volume 6(ELE)Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 WayNos334.95334.951.0FalseNoneNoneFalseNoneFalse334.950
3818678145241NonePg.No. 8 Item.No.3.4.7 Volume 6(ELE)Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 WayNos381.15381.151.0FalseNoneNoneFalseNoneFalse381.150
3818679145241NonePg.No. 8 Item.No.3.4.8 Volume 6(ELE)Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 WayNos425.25425.251.0FalseNoneNoneFalseNoneFalse425.250
3818680145241NonePg.No. 08 Item.No.3.5.3 Volume 6(ELE)Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleNos183.75183.752.0FalseNoneNoneFalseNoneFalse367.50
3818681145241NonePg.No. 08 Item.No.3.5.4 Volume 6(ELE)Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleNos245.7245.71.0FalseNoneNoneFalseNoneFalse245.70
3818682145241NonePg.No. 08 Item.No.3.5.5 Volume 6(ELE)Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleNos298.2298.21.0FalseNoneNoneFalseNoneFalse298.20
3818683145241NonePg.No. 08 Item.No.3.5.6 Volume 6(ELE)Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleNos361.2361.21.0FalseNoneNoneFalseNoneFalse361.20
3818684145241NonePg.No. 08 Item.No.3.5.7 Volume 6(ELE)Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16 ModuleNos416.85416.851.0FalseNoneNoneFalseNoneFalse416.850
3818685145241NonePg.No. 08 Item.No.3.5.8 Volume 6(ELE)Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18 ModuleNos479.85479.851.0FalseNoneNoneFalseNoneFalse479.850
3818686145241NonePg.No. 09 Item.No.3.6.1 Volume 6(ELE)Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchNos107.1107.122.0FalseNoneNoneFalseNoneFalse2356.20
3818687145241NonePg.No. 09 Item.No.3.6.3 Volume 6(ELE)Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socketNos179.55179.558.0FalseNoneNoneFalseNoneFalse1436.40
3818688145241NonePg.No. 09 Item.No.3.6.4 Volume 6(ELE)Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleNos374.85374.856.0FalseNoneNoneFalseNoneFalse2249.10
3818689145241NonePg.No. 10 Item.No.3.14.6 Volume 6(ELE)Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Pendant HolderNos74.5574.5516.0FalseNoneNoneFalseNoneFalse1192.80
3818690145241NonePg.No. 43 Item.No.11.3.3 Volume 6(ELE)Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 lumen maintenance with CRI greater than 80 Power Input 220 to 240V@ 50 or 60Hz & Power factor greate than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1X4 feet 36 or 40 WNos1332.451332.4510.0FalseNoneNoneFalseNoneFalse13324.50
3818691145241NonePg.No. 46 Item.No.11.8.4 Volume 6(ELE)Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location withminimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 90 WEach9303.09303.01.0FalseNoneNoneFalseNoneFalse9303.00
3818692145241NonePg.No. 45 Item.No.11.6.5 Volume 6(ELE)Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should greater than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested byNABL/CPRI accredited laboratory with 2 years Warranty againstany manufacturing defect working under standard electrical condition. LED modular down light 1'x4' 34-36WNos6192.96192.96.0FalseNoneNoneFalseNoneFalse37157.40
3818693145241NonePg.No. 43 Item.No.11.2.1 Volume 6(ELE)Supplying & fixing retrofit type-PL- LED Lamp . W LED linear source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HFelectronic driver integrated in the system, with PF greater than 0.95, power loss should Smaller than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Each654.15654.153.0FalseNoneNoneFalseNoneFalse1962.450
3818694145241NonePg.No. 56 Item.No.13.7.1 Volume 6(ELE)Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling /Rafter / GirdersNos128.1128.133.0FalseNoneNoneFalseNoneFalse4227.30
3818695145241NonePg.No. 30 Item.No.6.3.1 Volume 6(ELE)Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelNos3133.23133.26.0FalseNoneNoneFalseNoneFalse18799.20
3818696145241NonePg.No. 57 Item.No.13.11 Volume 6(ELE)Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Nos330.75330.756.0FalseNoneNoneFalseNoneFalse1984.50
3818697145241NonePg.No. 57 Item.No.13.12 Volume 6(ELE)Extra length of GI pipe of class B 19mm dia for down rod.Mtr206.85206.856.0FalseNoneNoneFalseNoneFalse1241.10
3818698145241NonePg.No. 30 Item.No.6.2.1 Volume 6(ELE)Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)Nos3117.453117.456.0FalseNoneNoneFalseNoneFalse18704.70
3818699145241NonePg.No. 57 Item.No.13.13 Volume 6(ELE)Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Nos742.35742.352.0FalseNoneNoneFalseNoneFalse1484.70
3818700145241NonePg.No. 17 Item.No.5.18.4 Volume 6(ELE)Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Typecurve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DPNos775.95775.953.0FalseNoneNoneFalseNoneFalse2327.850
3818701145241NonePg.No. 17 Item.No.5.18.5 Volume 6(ELE)Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Typecurve, indicator ON OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPNos1113.01113.01.0FalseNoneNoneFalseNoneFalse1113.00
3818702145241NonePg.No. 17 Item.No.5.17.2 Volume 6(ELE)Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 8 WayNos13235.2513235.251.0FalseNoneNoneFalseNoneFalse13235.250
3818703145241NonePg.No. 56 Item.No.13.1.1 Volume 6(ELE)Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeEach1026.91026.91.0FalseNoneNoneFalseNoneFalse1026.90
3818704145241NonePg.No. 2 Item.No.1.1.3 Volume 6(ELE)Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thickMtr111.3111.38.0FalseNoneNoneFalseNoneFalse890.40
3818705145241NonePg.No. 13 Item.No.32.05 Volume 6(ELE)1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Each148934.1148934.10.04FalseNoneNoneFalseNoneFalse5957.3640
3818706145241NonePg.No. 15 Item.No.35.01 Volume 6(ELE)Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 Sqmm page no.10Set340.2340.21.0FalseNoneNoneFalseNoneFalse340.20
3818707145241NonePg.No. 63 Item.No.29.03 Volume 6(ELE)Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Hard SoilCum408.45408.4511.62FalseNoneNoneFalseNoneFalse4746.1890
3818708145241NonePg.No. 52 Item.No.21.05 Volume 6(ELE)Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm21909.321909.30.04FalseNoneNoneFalseNoneFalse876.3720
3818709145241NonePg.No. 38 Item.No.48.04 Volume 6(ELE)GI Pipe B - Class as per IS-1239 GI Pipe - 40 mm DiaMtr262.5262.56.0FalseNoneNoneFalseNoneFalse1575.00
3818710145241NonePg.No. 22 Item.No.51.01 Volume 6(ELE)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNos780.15780.151.0FalseNoneNoneFalseNoneFalse780.150
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17241458990000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17241458990000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17241458990000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17241458990000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17241458990000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17241459300000NoneNoneELIGIBILITYTenderers are required to read the bid documents carefully before submission of their bidNone
17241459420000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the submitted tender bid shall be liable to be rejectedNone
17241459470000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt, orders as may be modified from time to timeNone
17241459520000NoneNoneELIGIBILITYThe tenderer shall scan original Workdone certificates Turnover Statements and any other documents specified by the employer and attach the scanned file to the Bid. The Original Documents shall be produced for physical verification within one week from the date of Technical bid openingNone
17241459570000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so everNone
17241459670000NoneNoneELIGIBILITYIf the quoted bid amount is less than the tendered amount, the difference in amount shall be remitted in the from of FDR DD Bank Guarantee in the name of Commissioner HDMC Hubli from any of the Nationalized Banks/Scheduled Banks and shall only be returned/refunded after the Completion of the Defect Liability PeriodNone
17241459760000NoneNoneELIGIBILITYThe Tenders/ Bids are invited as per Standard tender Bid Document KW1 The contractor shall attach all the requisite documents as required in the standard bid document. The Bidders shall abide as per the detailed instructions and conditions contained in standard bid document KW1None
17241459800000NoneNoneELIGIBILITYThe contractors shall collect necessary samples as required & all relevant requisite tests to be got done by the registered institution or firms with consultants with the Third PartyNone
17241459850000NoneNoneELIGIBILITYThe contractor has to make his own arrangements for procurement of all materials required for completion of the work in all respects. The contractor shall use relevant ISI mark materials for the work and also obtain necessary quality control certificates from the authorized quality control authorityNone
17241459900000NoneNoneELIGIBILITYTender application amount shall not be refundableNone
17241459950000NoneNoneELIGIBILITYThe contractor shall carry out the work preferably in 2 shifts to expedite and complete the work in all respects well before the stipulated timeNone
17241460000000NoneNoneELIGIBILITYThe Department is not responsible for any delay caused in accessing the e-procurement portalNone
17241460040000NoneNoneELIGIBILITYThe payments for the wok will be made depending upon the availability of fundsNone
17241460110000NoneNoneELIGIBILITYThe Defect liability Period for the work carried out is 360 days (1 years) from DATE OF COMPLETION OF WORKNone
17241460160000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight age of 10% per year to bring them to the price level of the 2024-25None
17241460200001NoneNoneELIGIBILITYThe time period for completion of the work is 6 monthsNone
17241460280000NoneNoneELIGIBILITYThe Applicable GST shall be paid separatelyNone
17241460320000NoneNoneELIGIBILITYList of works for which tenders already submitted and List of existing commitments and ongoing workNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid contractor license certificateTrueTechnical Bid
Similar nature of Work done certificate i e 50 percent of amount put to tenderTrueTechnical Bid
Line of Credit 30 percent of amount put to tenderTrueTechnical Bid
Financial Turnover certificate from 2019 20 to 2023 24 obtained and certified by the Registered valid chartered Accountant with UDIN Number detailsTrueTechnical Bid
GST CertificateTrueTechnical Bid
PAN cardTrueTechnical Bid
Information on works for which Tenders have been submitted A Existing commitments and on going worksTrueTechnical Bid
Information on works for which Tenders have been submitted B Works for which Tenders already submittedTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone